Você está na página 1de 15

VFT1

Time of Flight
Optical Barrier
The new Optical Barrier VFT1 is an innovative
optical barrier based on LED time of flight

One side detection – Without Reflector

May 2019 Optical Barrier VFT1 Presentation 2


The Optical Barrier VFT1 is based on principle of Time of Flight.

An infrared light is emitted in direction of target and receiver will get the diffuse
reflected signal.

Fig. Active spot area

May 2019 Optical Barrier VFT1 Presentation 3


 Detection range: from 0.8 to 10 m
 Up to 8 m on black surface (6% remission)
 Target temperature: from ambient up to 1.250ºC
 Response time: 2 ms on white matte surface at 2 m
to 14 ms on black surface (6% remission) at 8 m
 Detection resolution (min. distance between target
and background): between 150 mm and 300 mm
(hot surface)

 Designed for the steel industry environment


 Very easy to install and setup

May 2019 Optical Barrier VFT1 Presentation 4


Very easy to install and setup

 ❶: Sensor status, 3 LEDs


P.P. green = Product Presence,
Ctrl orange = low detection margin
Alarm red = internal temperature problem

 ❷ : Selector switch, to adjust sensitivity

 ❸ : Selector switch, to adjust distance

May 2019 Optical Barrier VFT1 Presentation 5


 Adjustment of Distance

The target distance must be between 0.8 m and 10 m.

The “Dist.” potentiometer must be adjusted between d1


(target distance) and d2 (background distance).
In case of short distance between d1 and d2, turn
clockwise potentiometer to detect on d2, turn it slowly
anticlockwise until the presence product PP turns OFF,
and check detection with a target at d1.

The difference between d1 and d2 should be higher than


150 mm, or 300 mm for black surface target over 6 m or
target with T above 1.000ºC.

May 2019 Optical Barrier VFT1 Presentation 6


 Adjustment of Distance, special cases:
– Detection of small target
For detection of small objects that will not fill completely the detection area, the detection will
be more accurate if the background is far from object. An absorbing surface can even be
used as background to increase repeatability and accuracy of detection.

:
– Detection of target with an angle
If there is an angle of incidence between sensor and target, the performances are affected:
the max. detection distance decrease and the max. response time increase.

– Detection with 2 sensors at the same location:


In case of detection with 2 sensors VFT1 used to detect at same location, the sensors
should be separated by at least 100 mm, as well as the detection area.

May 2019 Optical Barrier VFT1 Presentation 7


 Response time

The response time is automatically adjusted by the sensor.

Typical values of response time, depending on target surface and distance, are
given in this table:

Response Time - Auto Mode (“Sens./Laser” potentiometer position 7)


Distance / Surface White surface (80%) Grey surface (18%) Black surface (6%)
2m 1 ms 2 ms 3,5 ms
4m 1 ms 2 ms 7 ms
8m 2 ms 3,5 ms 14 ms

May 2019 Optical Barrier VFT1 Presentation 8


 Adjustment of Sensitivity

By default, the sensor is set to the highest sensitivity: “Sens./Laser” potentiometer on


position 7. This is optimized for most of the applications and the VFT1 adapts
automatically its integration time.

In some rare applications, it could be necessary to reduce sensitivity (by turning


anticlockwise the “Sens./Laser” potentiometer):
- when the product has a reflective or white surface and the background has an absorbing surface (ex.
Black) or is far.
- when there is a reflective or white surface background beyond 14 m. In such case, it’s also possible to
place a black background plate at this distance, or all type of background plate less than 14m.

May 2019 Optical Barrier VFT1 Presentation 9


 Alignment

A laser pointer helps for alignment.

It is switched ON when sensor is


switched ON and when user turns the
‘Sens/Laser’ potentiometer (also when
‘Dist.’ potentiometer is turned).

It is automatically switched OFF after


15 min.

May 2019 Optical Barrier VFT1 Presentation 10


 CONTROL: gives information of a too low detection
margin (check target surface or clean window)
o ‘Ctrl’ back panel LED = Orange

o ‘CT’ output = 24 VDC

 ALARM: gives information of an internal failure or


too high internal temperature
o ‘Alarm’ back panel LED = Red

o ‘AL’ output = 24 VDC

May 2019 Optical Barrier VFT1 Presentation 11


Comparison with existing solution IFM Efector 01D100:

Surface remission IFM DELTA


White 80% 10 m 10 m
Grey 18% 6m 10 m
Black 6% - 8m

May 2019 Optical Barrier VFT1 Presentation


 Heat shield to protect from direct radiation (for models VFT1-J•)

May 2019 Optical Barrier VFT1 Presentation 13


Example: VFT1-JC 24VDC L=2

May 2019 Optical Barrier VFT1 Presentation 14


More information on:

www.deltasensor.eu

May 2019 Optical Barrier VFT1 Presentation 15