Commissioning RET Using

Antenna Rosenberger in
SBTS17A
Initial Information
• BTS Type : Airscale BTS
• BTS SW version :SBTS17A_ENB_0000_000430_000304
• Antenna Type : RFS (APXVB4L26EX-I20) 10 Port
Antenna Port Assignment and RET Setting
Y3:LG1800
Y1:TDD Ant1,2

Y2:TDD Ant3,4 R1:LWG900

Y4:LU2100

RET PORT
1 2 3

FRGU
FXED
AZNA
Wiring Diagram FXDB
RET Activation
Add & setup MO RSL
• Go to Parameter RMOD(which will be setup as RET controller)
• Add MO “RSL”
• Set power DC to “true”
• Set HDLC Enabled to “true”
Antenna Detected by SBTS
06180601201322-MM => 1180547001-031 => ALD2 => sektor2
06180701200072-MM => 1180547001-025 => ALD1 => sektor1
06180701200362-MM => 1180547001-010 => ALD3 => sektor3
RET Activation
• After plan activation, RET should be detected by
BTS

Check One by One RETU


which covered Port
- RETU-1 for R1
- RETU-2 for Y1
- RETU-3 for Y2
- RETU-4 for Y3
- RETU-5 for Y4
RET Commissioning
• Go To Parameter Editor
• Add MO ALD-1 until ALD-3 under APEQM
• Fill in Details ALD parameters
• Please refers to Runtime view to fill ALD ID for this MO
Commissioning
• Add MO RETU-1 until RETU-5 for each ALD
• Please refer to site Runtime View to check RETU’s in detail.
• If others RET were planed to be used by other’s, fill “external” in
associated Antenna list
• Fill in the additional info as request by Project
• Please follow as example below

Additional Information sample


Commissioning

Commissioning template RETU1

Additional Information list


Commisioning

Commissioning template RETU2

Additional Information list


Commisioning

Commissioning template RETU3


Additional Information list
Commisioning
Cause Y3 connected to LTE1800
and use their RF to RET
Connection, so fill Ant port used
for each Antenna connection to
“List of Associated Antenna Lines”

Commissioning template RETU4

Additional Information list


Commisioning

Commissioning template
RETU5
Additional Information list
RET Activation
Add & Setup MO “LOGLINK”
• Go to Parameter HWTOP-1
• Add MO “loglink”
• Please refers to Runtime view to fill “firstEndpointDN” &
“secondEndpointDN” for this MO
Site Runtime View
After Plan Activation
RET testing

Before
Angles adjusting

Before
Angles adjusting

After
RFS Antenna Datasheet
Important Note
• Before Activating RET, Engineer need to know Antenna Type and have
SN Antenna each Sector
• SN antenna maybe appear in RET or ALD device based on Antenna
Type
• ALD and RETU Creation based on Runtime View BTS, its Mandatory
• For Antenna Type with 1 ALD 1 RET, always use SubUnitNumber = 1
• For Antenna Type with 1 ALD 4 RET, always use SubUnitNumber ID =
YX RETU
TERIMAKASIH