Você está na página 1de 73

1

Canon iR Advance C2025 Trouble Error Codes List page 1 (from 24)

Code Description Remedy


Fixing Assembly error, Fixing temperature detection
error 1. Check failure between the DC Controller
PCB (UN09/J12) and the Fixing Assembly
(UN37/J123,UN13/J13) (trapped cable, open circuit,
connector disconnection). -> Replace the part in the
Main Thermistor high case of trapped cable/open circuit 2. Disconnect the
temperature detection connector of DC Controller PCB (UN09/J12) and
E001- Main Thermistor 2 detected start the host machine to check the reading value of
0001 a temperature of 230 deg the following: service mode > COPIER > DISPLAY
C or higher for 0.1 sec or > ANALOG > FIX-C => When the value is 40 deg C
longer. or higher 3-1. Replace the DC Controller PCB
(UN09) => When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly NOTE: After
performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION
> CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
error 1. Check failure between the DC Controller
PCB (UN09/ J12) and the Fixing Assembly (UN37/
J123, UN13/ J13) (trapped cable, open circuit,
connector disconnection). -> Replace the part in the
Center Thermistor high case of trapped cable/open circuit 2. Disconnect the
temperature detection connector of DC Controller PCB (UN09/ J12) and
E001- Main Thermistor 1 detected start the host machine to check the reading value of
0002 a temperature of 283 deg the following: service mode > COPIER > DISPLAY
C or higher for 0.1 sec or > ANALOG > FIX-E => When the value is 40 deg C
longer. or higher 3-1. Replace the DC Controller PCB
(UN09) => When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly NOTE: After
performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION
> CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
error 1. Check failure between the DC Controller
Edge Thermistor high
PCB (UN09/ J12) and the Fixing Assembly (UN37/
temperature detection
J123, UN13/ J13) (trapped cable, open circuit,
E001- Sub Thermistor 1 detected
connector disconnection). -> Replace the part in the
0003 a temperature of 283 deg
case of trapped cable/open circuit 2. Disconnect the
C or higher for 0.1 sec or
connector of DC Controller PCB (UN09/ J12) and
longer.
start the host machine to check the reading value of
the following: service mode > COPIER > DISPLAY
2

> ANALOG > FIX-E2 => When the value is 40 deg


C or higher 3-1. Replace the DC Controller PCB
(UN09) => When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly NOTE: After
performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION
> CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
error 1. Check failure between the DC Controller
PCB (UN09/ J12) and the Fixing Assembly (UN37/
J123, UN13/ J13) (trapped cable, open circuit,
connector disconnection). -> Replace the part in the
Edge Thermistor high case of trapped cable/open circuit 2. Disconnect the
temperature detection connector of DC Controller PCB (UN09/ J12) and
E001- Sub Thermistor 2 detected start the host machine to check the reading value of
0004 a temperature of 283 deg the following: service mode > COPIER > DISPLAY
C or higher for 0.1 sec or > ANALOG > FIX-E3 => When the value is 40 deg
longer. C or higher 3-1. Replace the DC Controller PCB
(UN09) => When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly NOTE: After
performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION
> CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
error 1. Check failure between the DC Controller
PCB (UN09/ J12) and the Fixing Assembly (UN37/
J123, UN13/ J13) (trapped cable, open circuit,
connector disconnection). -> Replace the part in the
Center Thermistor high case of trapped cable/open circuit 2. Disconnect the
temperature detection connector of DC Controller PCB (UN09/ J12) and
E001- Main Thermistor 1 start the host machine to check the reading value of
0005 hardware signal is the following: service mode > COPIER > DISPLAY
continued for 1 sec or > ANALOG > FIX-E => When the value is 40 deg C
longer. or higher 3-1. Replace the DC Controller PCB
(UN09) => When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly NOTE: After
performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION
> CLEAR > ERR
Edge Thermistor high Fixing Assembly error, Fixing temperature detection
temperature detection error 1. Check failure between the DC Controller
E001- Sub Thermistor 1 hardware PCB (UN09/ J12) and the Fixing Assembly (UN37/
0006 error detection signal is J123, UN13/ J13) (trapped cable, open circuit,
continued for 1 sec or connector disconnection). -> Replace the part in the
longer. case of trapped cable/open circuit 2. Disconnect the
3

connector of DC Controller PCB (UN09/ J12) and


start the host machine to check the reading value of
the following: service mode > COPIER > DISPLAY
> ANALOG > FIX-E2 => When the value is 40 deg
C or higher 3-1. Replace the DC Controller PCB
(UN09) => When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly NOTE: After
performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION
> CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
error 1. Check failure between the DC Controller
PCB (UN09/ J12) and the Fixing Assembly (UN37/
J123, UN13/ J13) (trapped cable, open circuit,
connector disconnection). -> Replace the part in the
case of trapped cable/open circuit 2. Disconnect the
Edge Thermistor high connector of DC Controller PCB (UN09/ J12) and
temperature detection start the host machine to check the reading value of
E001- Sub Thermistor 2 hardware the following: service mode > COPIER > DISPLAY
0007 error detection signal is > ANALOG > FIX-C Check the reading value of the
continued for 1 sec or following: service mode > COPIER > DISPLAY >
longer. ANALOG > FIX-E3 => When the value is 40 deg C
or higher 3-1. Replace the DC Controller PCB
(UN09) => When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly NOTE: After
performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION
> CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
error 1. Check failure between the DC Controller
PCB (UN09/ J12) and the Fixing Assembly (UN37/
J123, UN13/ J13) (trapped cable, open circuit,
connector disconnection). -> Replace the part in the
Displacement detection
case of trapped cable/open circuit 2. Disconnect the
The temperature difference
connector of DC Controller PCB (UN09/ J12) and
between the Sub
E001- start the host machine to check the reading value of
Thermistor 1 (TH3) and the
0008 the following: service mode > COPIER > DISPLAY
Sub Thermistor 2 (TH4)
> ANALOG > FIX-E2,FIX-E3 => When the value of
remained 45 deg C or
either one is 40 deg C or higher 3-1. Replace the
more for 1 second or more.
DC Controller PCB (UN09) => When the both
values are lower than 40 deg C 3-2. Replace the
Fixing Assembly NOTE: After performing the above
remedy work, go through the following to clear the
error: COPIER > FUNCTION > CLEAR > ERR
E002- Detection of abnormal 1. Check the location for voltage of the Fixing
4

0006 temperature increase Assembly -> Replace with a correct Fixing


Fixing Assembly error, Assembly for the location in the case of
Fixing temperature mismatching. 2. Check the location for voltage of
detection error the AC Driver PCB (UN14) -> Replace with a
correct AC Driver PCB (UN14) for the location in
the case of mismatching. 3. Check failure between
the AC Driver PCB (UN14/J103) and the Fixing
Assembly (UN37/J123, UN13/J13). (trapped cable,
open circuit, connector disconnection) -> Replace
the part in the case of trapped cable/open circuit 4.
Replace the AC Driver PCB (UN14) 5. Replace the
Fixing Assembly 6. Replace the DC Controller PCB
(UN09) NOTE: After performing the above remedy
work, go through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
Thermistor open circuit error 1. Check failure between the DC Controller
detection PCB (UN09/ J12) and the Fixing Assembly (UN37/
In the period from initial J123, UN13/ J13) (trapped cable, open circuit,
E003- rotation to printing, Main connector disconnection). -> Replace the part in the
0001 Thermistor 1 detected a case of trapped cable/open circuit 2. Replace the
temperature of 22 deg C or Fixing Assembly 3. Replace the DC Controller PCB
lower for more than 5 (UN09) NOTE: After performing the above remedy
seconds. work, go through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
Thermistor open circuit error 1. Check failure between the DC Controller
detection PCB (UN09/ J12) and the Fixing Assembly (UN37/
In the period from initial J123, UN13/ J13) (trapped cable, open circuit,
E003- rotation to printing, Main connector disconnection). -> Replace the part in the
0002 Thermistor 2 detected a case of trapped cable/open circuit 2. Replace the
temperature of 40 deg C or Fixing Assembly 3. Replace the DC Controller PCB
lower for more than 3 (UN09) NOTE: After performing the above remedy
seconds. work, go through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
Thermistor open circuit error 1. Check failure between the DC Controller
detection PCB (UN09/ J12) and the Fixing Assembly (UN37/
In the period from initial J123, UN13/ J13) (trapped cable, open circuit,
E003- rotation to printing, Sub connector disconnection). -> Replace the part in the
0003 Thermistor 1 detected a case of trapped cable/open circuit 2. Replace the
temperature of 40 deg C or Fixing Assembly 3. Replace the DC Controller PCB
lower for more than 3 (UN09) NOTE: After performing the above remedy
seconds. work, go through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR
5

Fixing Assembly error, Fixing temperature detection


Thermistor open circuit error 1. Check failure between the DC Controller
detection PCB (UN09/ J12) and the Fixing Assembly (UN37/
In the period from initial J123, UN13/ J13) (trapped cable, open circuit,
E003- rotation to printing, Sub connector disconnection). -> Replace the part in the
0004 Thermistor 2 detected a case of trapped cable/open circuit 2. Replace the
temperature of 40 deg C or Fixing Assembly 3. Replace the DC Controller PCB
lower for more than 3 (UN09) NOTE: After performing the above remedy
seconds. work, go through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
Main Thermistor 2 low
error 1. Check failure between the DC Controller
temperature detection at
PCB (UN09/ J12) and the Fixing Assembly (UN37/
printing
J123, UN13/ J13) (trapped cable, open circuit,
In the period from printing
E003- connector disconnection). -> Replace the part in the
to last rotation, Main
0005 case of trapped cable/open circuit 2. Replace the
Thermistor 1 detected a
Fixing Assembly 3. Replace the DC Controller PCB
temperature of 70 deg C or
(UN09) NOTE: After performing the above remedy
lower for more than 5
work, go through the following to clear the error:
seconds.
COPIER > FUNCTION > CLEAR > ERR
Fixing Assembly error, Fixing temperature detection
Center Thermistor low
error 1. Check failure between the DC Controller
temperature detection at
PCB (UN09/ J12) and the Fixing Assembly (UN37/
printing
J123, UN13/ J13) (trapped cable, open circuit,
In the period from printing
E003- connector disconnection). -> Replace the part in the
to last rotation, Main
0006 case of trapped cable/open circuit 2. Replace the
Thermistor 2 detected a
Fixing Assembly 3. Replace the DC Controller PCB
temperature of 80 deg C or
(UN09) NOTE: After performing the above remedy
lower for more than 1
work, go through the following to clear the error:
second.
COPIER > FUNCTION > CLEAR > ERR
6

Code Description Remedy


Fixing Assembly error, Fixing temperature
detection error 1. Check failure between the
Edge Thermistor low DC Controller PCB (UN09/ J12) and the
temperature detection at Fixing Assembly (UN37/ J123, UN13/ J13)
printing (trapped cable, open circuit, connector
E003- In the period from printing to disconnection). -> Replace the part in the
0007 last rotation, Sub Thermistor 1 case of trapped cable/open circuit 2.
detected a temperature of 80 Replace the Fixing Assembly 3. Replace the
deg C or lower for more than 1 DC Controller PCB (UN09) NOTE: After
second. performing the above remedy work, go
through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR
Fixing Assembly error, Fixing temperature
detection error 1. Check failure between the
Edge Thermistor low DC Controller PCB (UN09/ J12) and the
temperature detection at Fixing Assembly (UN37/ J123, UN13/ J13)
printing (trapped cable, open circuit, connector
E003- In the period from printing to disconnection). -> Replace the part in the
0008 last rotation, Sub Thermistor 2 case of trapped cable/open circuit 2.
detected a temperature of 80 Replace the Fixing Assembly 3. Replace the
deg C or lower for more than 1 DC Controller PCB (UN09) NOTE: After
second. performing the above remedy work, go
through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR
Fixing Relay PCB welding
Electrical trouble with abnormal fixing safety
E004- detection error
circuit relay Replace the AC Driver PCB
0001 Zero cross interruption although
(UN14)
relay is not ON.
Electrical trouble with abnormal fixing
Failure in electrical current current detection circuit 1. Check failure
detection circuit (abnormal between the AC Driver PCB (UN14/ J122)
small current) and the DC Controller PCB (UN09/ J10).
E004-
Failure in electrical current (trapped cable, open circuit, connector
0005
detection circuit (Less than the disconnection) -> Replace the part in the
specified range of current case of trapped cable/open circuit 2.
value) Replace the AC Driver PCB (UN14) 3.
Replace the DC Controller PCB (UN09)
Failure in electrical current Electrical trouble with abnormal fixing
detection circuit (abnormal current detection circuit 1. Check failure
E004-
large current) between the AC Driver PCB (UN14/ J122)
0006
Failure in electrical current and the DC Controller PCB (UN09/ J10).
detection circuit (More than the (trapped cable, open circuit, connector
7

specified range of current disconnection) -> Replace the part in the


value) case of trapped cable/open circuit 2.
Replace the AC Driver PCB (UN14) 3.
Replace the DC Controller PCB (UN09)
Possible cause is overload or rotation failure
of the motor due to an electrical trouble 1.
Check if the Fixing Assembly is installed. 2.
Remove and reinstall the Fixing Assembly 3.
Fixing Film Unit engagement / Check the gear 4. Replace the Fixing
disengagement error Assembly 5. Check the harness/connector
There is no change in the result between the DC Controller PCB (UN09/
E009- of detection by the Fixing J210) and the Fixing Motor (M17). 6. Check
0000 Pressure Release Sensor even the harness/connector between the DC
after five seconds elapsed after Controller PCB (UN09/ J12) and the Fixing
counterclockwise rotation of the Pressure Release Sensor (PS24) 6. Check
Fixing Motor started. conduction of FU1153 in the AC Driver PCB
(UN14) => Replace the AC Driver PCB
(UN14) in the case of disconnection. 7.
Replace the Fixing Motor (M17) 8. Replace
the DC Controller PCB (UN09)
Possible cause is overload or rotation failure
of the motor due to an electrical trouble 1.
Check the Main Drive Unit (turn the unit by
hand to see if it rotates) Replace the Main
Drive Unit when the unit failed to rotate
When the unit rotates 2. Check failure of the
harness between the ITB Motor (M02/
ITB Motor startup error
J6027) and the DC Controller PCB (UN09/
E010- Within a specified period of
J210W) (trapped cable, open circuit,
0001 time from the startup, the speed
connector disconnection) 3. Check
fails to be OK.
conduction of the fuse (FU4) in the DC
Controller PCB (UN09) When the fuse is not
blown out 4-1. Replace the ITB Motor (M02)
5-1. Replace the DC Controller PCB (UN09)
6-1. Replace the Main Drive Unit When the
fuse is blown out 4-2. Replace the DC
Controller PCB (UN09)
Possible cause is overload or rotation failure
of the motor due to an electrical trouble 1.
Check the Main Drive Unit (turn the unit by
E010- hand to see if it rotates) Replace the Main
ITB Motor speed error
0002 Drive Unit when the unit failed to rotate
When the unit rotates 2. Check failure of the
harness between the ITB Motor (M02/
J6027) and the DC Controller PCB (UN09/
8

J210W) (trapped cable, open circuit,


connector disconnection) 3. Check
conduction of the fuse (FU4) in the DC
Controller PCB (UN09) When the fuse is not
blown out 4-1. Replace the ITB Motor (M02)
5-1. Replace the DC Controller PCB (UN09)
6-1. Replace the Main Drive Unit When the
fuse is blown out 4-2. Replace the DC
Controller PCB (UN09)
Possible cause is overload or rotation failure
of the motor due to an electrical trouble 1.
Check the Main Drive Unit (turn the unit by
hand to see if it rotates) Replace the Main
Drive Unit when the unit failed to rotate
When the unit rotates 2. Check failure of the
harness between the ITB Motor (M02/
ITB Motor lock detection
J6027) and the DC Controller PCB (UN09/
E010- Within a specified period of
J210W) (trapped cable, open circuit,
0003 time from the startup, signal is
connector disconnection) 3. Check
not received.
conduction of the fuse (FU4) in the DC
Controller PCB (UN09) When the fuse is not
blown out 4-1. Replace the ITB Motor (M02)
5-1. Replace the DC Controller PCB (UN09)
6-1. Replace the Main Drive Unit When the
fuse is blown out 4-2. Replace the DC
Controller PCB (UN09)
Possible cause is overload or rotation failure
of the motor due to an electrical trouble 1.
Check the Main Drive Unit (turn the unit by
hand to see if it rotates) Replace the Main
Drive Unit when the unit failed to rotate
When the unit rotates 2. Check failure of the
CL Drum Motor speed error harness between the Motor (M04/ J6025)
E012- Within a specified period of and the DC Controller PCB (UN09/ J210W)
0001 time from the startup, the speed (trapped cable, open circuit, connector
fails to be OK. disconnection) 3. Check conduction of the
fuse (FU7) in the DC Controller PCB (UN09)
When the fuse is not blown out 4-1. Replace
the Drum Motor (M04) 5-1. Replace the DC
Controller PCB (UN09) When the fuse is
blown out 4-2. Replace the DC Controller
PCB (UN09)
Possible cause is overload or rotation failure
E012-
CL Drum Motor speed error of the motor due to an electrical trouble 1.
0002
Check the Main Drive Unit (turn the unit by
9

hand to see if it rotates) Replace the Main


Drive Unit when the unit failed to rotate
When the unit rotates 2. Check failure of the
harness between the Motor (M04/ J6025)
and the DC Controller PCB (UN09/ J210W)
(trapped cable, open circuit, connector
disconnection) 3. Check conduction of the
fuse (FU7) in the DC Controller PCB (UN09)
When the fuse is not blown out 4-1. Replace
the Drum Motor (M04) 5-1. Replace the DC
Controller PCB (UN09) When the fuse is
blown out 4-2. Replace the DC Controller
PCB (UN09)
Possible cause is overload or rotation failure
of the motor due to an electrical trouble 1.
Check the Main Drive Unit (turn the unit by
hand to see if it rotates) Replace the Main
Drive Unit when the unit failed to rotate
When the unit rotates 2. Check failure of the
CL Drum Motor lock detection harness between the Motor (M04/ J6025)
E012- Within a specified period of and the DC Controller PCB (UN09/ J210W)
0003 time from the startup, the speed (trapped cable, open circuit, connector
fails to be OK. disconnection) 3. Check conduction of the
fuse (FU7) in the DC Controller PCB (UN09)
When the fuse is not blown out 4-1. Replace
the Drum Motor (M04) 5-1. Replace the DC
Controller PCB (UN09) When the fuse is
blown out 4-2. Replace the DC Controller
PCB (UN09)
Possible cause is overload or rotation failure
of the motor due to an electrical trouble 1.
Check if the Fixing Assembly is installed. 2.
Remove and reinstall the Fixing Assembly 3.
Check the gear 4. Replace the Fixing
Fixing Motor startup error
Assembly 5. Check the harness/connector
E014- Within a specified period of
between the DC Controller PCB (UN09/
0001 time from the startup, the speed
J210) and the Fixing Motor (M17). 6. Check
fails to be OK.
conduction of FU1153 in the AC Driver PCB
(UN14) =>Replace the AC Driver when the
fuse is blown out 7. Replace the Fixing
Motor (M17) 8. Replace the DC Controller
PCB (UN09)
Possible cause is overload or rotation failure
E014-
Fixing Motor speed errorond. of the motor due to an electrical trouble 1.
0002
Check if the Fixing Assembly is installed. 2.
10

Remove and reinstall the Fixing Assembly 3.


Check the gear 4. Replace the Fixing
Assembly 5. Check the harness/connector
between the DC Controller PCB (UN09/
J210) and the Fixing Motor (M17). 6. Check
conduction of FU1153 in the AC Driver PCB
(UN14) =>Replace the AC Driver when the
fuse is blown out 7. Replace the Fixing
Motor (M17) 8. Replace the DC Controller
PCB (UN09)
Possible cause is overload or rotation failure
of the motor due to an electrical trouble 1.
Check if the Fixing Assembly is installed. 2.
Remove and reinstall the Fixing Assembly 3.
Check the gear 4. Replace the Fixing
Fixing Motor lock detection.
Assembly 5. Check the harness/connector
E014- Within a specified period of
between the DC Controller PCB (UN09/
0003 time from the startup, signal is
J210) and the Fixing Motor (M17). 6. Check
not received.
conduction of FU1153 in the AC Driver PCB
(UN14) =>Replace the AC Driver when the
fuse is blown out 7. Replace the Fixing
Motor (M17) 8. Replace the DC Controller
PCB (UN09)

Code Description Remedy


ATR Sensor (Y) error or
1. Check if the Drum Unit (Y) is installed. 2. Check
toner supply error
the Drum Unit Relay PCB (Y) (UN26) 3. Check the
Error in detected TD ratio.
Drum Unit Memory PCB (Y) (UN30) 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0020 reference value is the
(UN09/ J25) and the Drum Unit Relay PCB (Y)
specified value or lower at
(UN26). 5. Replace the Drum Unit (Y). 6. Replace
the time of ATR Sensor (Y)
the DC Controller PCB (UN09)
initialization.
ATR Sensor (Y) error or
1. Check if the Drum Unit (Y) is installed. 2. Check
toner supply error
the Drum Unit Relay PCB (Y) (UN26) 3. Check the
Error in detected TD ratio.
Drum Unit Memory PCB (Y) (UN30) 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0030 reference value is the
(UN09/ J25) and the Drum Unit Relay PCB (Y)
specified value or higher at
(UN26). 5. Replace the Drum Unit (Y). 6. Replace
the time of ATR Sensor (Y)
the DC Controller PCB (UN09)
initialization.
11

1. Check if the Drum Unit (Y) is installed. 2. Check


ATR Sensor (Y) error or the Drum Unit Relay PCB (Y) (UN26) 3. Check the
toner supply error Drum Unit Memory PCB (Y) (UN30) 4. Check the
E020-
Unable to adjust the control harness/connector between the DC Controller PCB
0040
voltage at the time of ATR (UN09/ J25) and the Drum Unit Relay PCB (Y)
Sensor (Y) initialization. (UN26). 5. Replace the Drum Unit (Y). 6. Replace
the DC Controller PCB (UN09)
1. Check if the Drum Unit (Y) is installed. 2. Check
ATR Sensor (Y) error or the Drum Unit Relay PCB (Y) (UN26) 3. Check the
toner supply error Drum Unit Memory PCB (Y) (UN30) 4. Check the
E020-
Unable to adjust the control harness/connector between the DC Controller PCB
0041
voltage at the time of ATR (UN09/ J25) and the Drum Unit Relay PCB (Y)
Sensor (Y) initialization. (UN26). 5. Replace the Drum Unit (Y). 6. Replace
the DC Controller PCB (UN09)
1. Clean the scanner’s window. 2. Use your hand to
check if the shutter of the Registration Patch
Sensor Unit can be open. 3. Check if the window of
the Patch Sensor (UN43/ UN44) is soiled. 4. Check
scar on the ITB. 5. Check movement of the
Registration Shutter Solenoid (SL02). COPIER >
FUNCTION > PART-CHK > SL to move SL02 6.
ATR patch failed to be Check the harness/connector between the DC
created correctly or Patch Controller PCB (UN09/J12) and the Patch Sensors
E020-
Sensor error (UN43/J4007, UN44, J4006). 7.Replace the Drum
0050
High density for the target Unit (Y) 8.Replace the Registration Patch Sensor
at patch detection Unit 9 Replace the ITB Unit. 10. Check conduction
of the fuses (FU5, FU8) in the DC Controller PCB
(UN09). 11. Replace the Primary Transfer High
Voltage PCB (UN04) 12. Replace the Developing
High Voltage PCB (UN07) 13. Replace the Primary
Charging High Voltage PCB (UN06) 14. Replace
the Auxiliary High Voltage PCB (UN08) 15. Replace
the Replace the DC Controller PCB (UN09)
1. Check the patch shape. 2. Clean the high voltage
contact point with dry wiping or air blower. 3. Check
the harness/connector between the DC Controller
(UN09) and the High Voltage PCB. Between the
ATR patch failed to be
DC Controller PCB (UN09/ J21) and the Primary
created correctly or Patch
E020- Charging High Voltage PCB (UN06/ J441, J442)
Sensor error
0060 Between the DC Controller PCB (UN09/ J21, J22)
High density for the target
and the Developing High Voltage PCB (UN07/
at patch detection
J451, J452) Between the DC Controller PCB
(UN09/ J19) and the Auxiliary High Voltage PCB
(UN08/J461, J462) Between the DC Controller PCB
(J205) and the Primary Transfer High Voltage PCB
12

(UN04/J1001) 4. Replace the Drum Unit (Y) 5.


Replace the Registration Patch Sensor Unit 6.
Replace the ITB Unit. 7. Check conduction of the
fuses (FU5, FU8) in the DC Controller PCB (UN09).
8. Replace the Primary Transfer High Voltage PCB
(UN04) 9. Replace the Developing High Voltage
PCB (UN07) 10. Replace the Primary Charging
High Voltage PCB (UN06) 11. Replace the Auxiliary
High Voltage PCB (UN08) 12. Replace the DC
Controller PCB (UN09)
Patch Sensor error
The Patch Sensor could
E020- 1.Turn OFF and then ON the power. 2.Replace the
not read a patch properly.
0070 ITB Unit.
(Patch error due to
software or the ITB Unit)
1. Check if the Drum Unit (Y) is installed. 2. Check
ATR Sensor (Y) error or
the Drum Unit Relay PCB (Y) (UN26) 3. Check the
toner supply error
Drum Unit Memory PCB (Y) (UN30) 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0090 Sensor (Y) detection value
(UN09/ J25) and the Drum Unit Relay PCB (Y)
is the specified value or
(UN26). 5. Replace the Drum Unit (Y). 6. Replace
lower.
the DC Controller PCB (UN09)
1. Check if the Drum Unit (Y) is installed. 2. Check
ATR Sensor (Y) error or
the Drum Unit Relay PCB (Y) (UN26) 3. Check the
toner supply error
Drum Unit Memory PCB (Y) (UN30) 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0091 Sensor (Y) detection value
(UN09/ J25) and the Drum Unit Relay PCB (Y)
is the specified value or
(UN26). 5. Replace the Drum Unit (Y). 6. Replace
higher.
the DC Controller PCB (UN09)
ATR Sensor (Y) error or 1. Check if the Drum Unit (Y) is installed. 2. Check
toner supply error the Drum Unit Relay PCB (Y) (UN26) 3. Check the
T/D ratio detected by the Drum Unit Memory PCB (Y) (UN30) 4. Check the
E020-
ATR Sensor (Y) (UN39) is harness/connector between the DC Controller PCB
00B0
equal to or higher than the (UN09/ J25) and the Drum Unit Relay PCB (Y)
specified value (high (UN26). 5. Replace the Drum Unit (Y). 6. Replace
density) the DC Controller PCB (UN09)
ATR Sensor (Y) error or
Possible cause: overload with the motor or motor
toner supply error
failure 1. Check conduction with FU2 on the DC
Error in detected delta T/D
Controller PCB (UN09) 2. Check the
E020- ratio T/D ratio detected by
harness/connector between the DC Controller PCB
00B1 the ATR Sensor (Y)
(UN09/ J23) and PS06. 3. Replace the DC
(UN39) is equal to or lower
Controller PCB (UN09) 4. Check the Hopper Unit
than the specified value
(Y) 5. Replace the Hopper Unit (Y).
(light density)
13

ATR Sensor (M) error or


1. Check if the Drum Unit (M) is installed. 2. Check
toner supply error
the Drum Unit Relay PCB (M) (UN27). 3. Check the
Error in detected TD ratio.
Drum Unit Memory PCB (M) (UN31). 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0120 reference value is the
(UN09/ J25) and the Drum Unit Relay PCB (M)
specified value or lower at
(UN27). 5. Replace the Drum Unit (M). 6. Replace
the time of ATR Sensor (M)
the DC Controller PCB (UN09)
initialization.
ATR Sensor (M) error or
1. Check if the Drum Unit (M) is installed. 2. Check
toner supply error
the Drum Unit Relay PCB (M) (UN27). 3. Check the
Error in detected TD ratio.
Drum Unit Memory PCB (M) (UN31). 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0130 reference value is the
(UN09/ J25) and the Drum Unit Relay PCB (M)
specified value or higher at
(UN27). 5. Replace the Drum Unit (M). 6. Replace
the time of ATR Sensor (M)
the DC Controller PCB (UN09)
initialization.
1. Check if the Drum Unit (M) is installed. 2. Check
ATR Sensor (M) error or the Drum Unit Relay PCB (M) (UN27). 3. Check the
toner supply error Drum Unit Memory PCB (M) (UN31). 4. Check the
E020-
Unable to adjust the control harness/connector between the DC Controller PCB
0140
voltage at the time of ATR (UN09/ J25) and the Drum Unit Relay PCB (M)
Sensor (M) initialization (UN27). 5. Replace the Drum Unit (M). 6. Replace
the DC Controller PCB (UN09)
1. Check if the Drum Unit (M) is installed. 2. Check
ATR Sensor (M) error or the Drum Unit Relay PCB (M) (UN27). 3. Check the
toner supply error Drum Unit Memory PCB (M) (UN31). 4. Check the
E020-
Unable to adjust the control harness/connector between the DC Controller PCB
0141
voltage at the time of ATR (UN09/ J25) and the Drum Unit Relay PCB (M)
Sensor (M) initialization. (UN27). 5. Replace the Drum Unit (M). 6. Replace
the DC Controller PCB (UN09)

Code Description Remedy


1. Clean the scanner’s window. 2. Use your hand
to check if the shutter of the Registration Patch
Sensor Unit can be open. 3. Check if the window of
ATR patch failed to be
the Patch Sensor (UN43/ UN44) is soiled. 4. Check
created correctly or Patch
E020- scar on the ITB. 5. Check movement of the
Sensor error
0150 Registration Shutter Solenoid (SL02). COPIER >
High density for the target
FUNCTION > PART-CHK > SL to move SL02 6.
at patch detection
Check the harness/connector between the DC
Controller PCB (UN09/J12) and the Patch Sensors
(UN43/J4007, UN44, J4006). 7.Replace the Drum
14

Unit (M) 8.Replace the Registration Patch Sensor


Unit 9 Replace the ITB Unit. 10. Check conduction
of the fuses (FU5, FU8) in the DC Controller PCB
(UN09). 11. Replace the Primary Transfer High
Voltage PCB (UN04) 12. Replace the Developing
High Voltage PCB (UN07) 13. Replace the Primary
Charging High Voltage PCB (UN06) 14. Replace
the Auxiliary High Voltage PCB (UN08) 15.
Replace the Replace the DC Controller PCB
(UN09)
1. Check the patch shape. 2. Clean the high
voltage contact point with dry wiping or air blower.
3. Check the harness/connector between the DC
Controller (UN09) and the High Voltage PCB.
Between the DC Controller PCB (UN09/ J21) and
the Primary Charging High Voltage PCB (UN06/
J441, J442) Between the DC Controller PCB
(UN09/ J21, J22) and the Developing High Voltage
PCB (UN07/ J451, J452) Between the DC
ATR patch failed to be
Controller PCB (UN09/ J19) and the Auxiliary High
created correctly or Patch
E020- Voltage PCB (UN08/J461, J462) Between the DC
Sensor error
0160 Controller PCB (J205) and the Primary Transfer
High density for the target
High Voltage PCB (UN04/J1001) 4. Replace the
at patch detection
Drum Unit (M) 5. Replace the Registration Patch
Sensor Unit 6. Replace the ITB Unit. 7. Check
conduction of the fuses (FU5, FU8) in the DC
Controller PCB (UN09). 8. Replace the Primary
Transfer High Voltage PCB (UN04) 9. Replace the
Developing High Voltage PCB (UN07) 10. Replace
the Primary Charging High Voltage PCB (UN06)
11. Replace the Auxiliary High Voltage PCB
(UN08) 12. Replace the DC Controller PCB (UN09)
Patch Sensor error
The Patch Sensor could not
E020- 1.Turn OFF and then ON the power. 2.Replace the
read a patch properly.
0170 ITB Unit.
(Patch error due to
software or the ITB Unit)
1. Check if the Drum Unit (M) is installed. 2. Check
ATR Sensor (M) error or
the Drum Unit Relay PCB (M) (UN27). 3. Check the
toner supply error
Drum Unit Memory PCB (M) (UN31). 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0190 Sensor (M) detection value
(UN09/ J25) and the Drum Unit Relay PCB (M)
is the specified value or
(UN27). 5. Replace the Drum Unit (M). 6. Replace
lower.
the DC Controller PCB (UN09)
15

1. Check if the Drum Unit (M) is installed. 2. Check


ATR Sensor (M) error or
the Drum Unit Relay PCB (M) (UN27). 3. Check the
toner supply error
Drum Unit Memory PCB (M) (UN31). 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0191 Sensor (M) detection value
(UN09/ J25) and the Drum Unit Relay PCB (M)
is the specified value or
(UN27). 5. Replace the Drum Unit (M). 6. Replace
higher.
the DC Controller PCB (UN09)
ATR Sensor (M) error or 1. Check if the Drum Unit (M) is installed. 2. Check
toner supply error the Drum Unit Relay PCB (M) (UN27). 3. Check the
The T/D ratio detected by Drum Unit Memory PCB (M) (UN31). 4. Check the
E020-
the ATR Sensor (M) harness/connector between the DC Controller PCB
01B0
(UN40) is equal to or higher (UN09/ J25) and the Drum Unit Relay PCB (M)
than the specified value (UN27). 5. Replace the Drum Unit (M). 6. Replace
(high density) the DC Controller PCB (UN09)
ATR Sensor (M) error or
Overload of the motor or motor failure 1. Check
toner supply error
conduction with FU2 on the DC Controller PCB
Error in detected delta T/D
(UN09) 2. Check the harness/connector between
E020- ratio The T/D ratio detected
the DC Controller PCB (UN09/J24) and PS07. 3.
01B1 by the ATR Sensor (M)
Replace the DC Controller PCB (UN09) 4. Check
(UN40) is equal to or lower
the Hopper Unit (M) 5. Replace the Hopper Unit
than the specified value
(M).
(light density)
ATR Sensor (C) error or
1. Check if the Drum Unit (C) is installed. 2. Check
toner supply error
the Drum Unit Relay PCB (C) (UN28) 3. Check the
Error in detected TD ratio.
Drum Unit Memory PCB (C) (UN32) 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0220 reference value is the
(UN09/ J25) and the Drum Unit Relay PCB (C)
specified value or lower at
(UN28). 5. Replace the Drum Unit (C). 6. Replace
the time of ATR Sensor (C)
the DC Controller PCB (UN09)
initialization.
ATR Sensor (C) error or
1. Check if the Drum Unit (C) is installed. 2. Check
toner supply error
the Drum Unit Relay PCB (C) (UN28) 3. Check the
Error in detected TD ratio.
Drum Unit Memory PCB (C) (UN32) 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0230 reference value is the
(UN09/ J25) and the Drum Unit Relay PCB (C)
specified value or higher at
(UN28). 5. Replace the Drum Unit (C). 6. Replace
the time of ATR Sensor (C)
the DC Controller PCB (UN09)
initialization.
1. Check if the Drum Unit (C) is installed. 2. Check
ATR Sensor (C) error or
the Drum Unit Relay PCB (C) (UN28) 3. Check the
toner supply error
E020- Drum Unit Memory PCB (C) (UN32) 4. Check the
Unable to adjust the control
0240 harness/connector between the DC Controller PCB
voltage at the time of ATR
(UN09/ J25) and the Drum Unit Relay PCB (C)
Sensor (C) initialization.
(UN28). 5. Replace the Drum Unit (C). 6. Replace
16

the DC Controller PCB (UN09)


1. Check if the Drum Unit (C) is installed. 2. Check
ATR Sensor (C) error or the Drum Unit Relay PCB (C) (UN28) 3. Check the
toner supply error Drum Unit Memory PCB (C) (UN32) 4. Check the
E020-
Unable to adjust the control harness/connector between the DC Controller PCB
0241
voltage at the time of ATR (UN09/ J25) and the Drum Unit Relay PCB (C)
Sensor (C) initialization. (UN28). 5. Replace the Drum Unit (C). 6. Replace
the DC Controller PCB (UN09)
1. Clean the scanner’s window. 2. Use your hand
to check if the shutter of the Registration Patch
Sensor Unit can be open. 3. Check if the window of
the Patch Sensor (UN43/ UN44) is soiled. 4. Check
scar on the ITB. 5. Check movement of the
Registration Shutter Solenoid (SL02). COPIER >
FUNCTION > PART-CHK > SL to move SL02 6.
Check the harness/connector between the DC
ATR patch failed to be
Controller PCB (UN09/J12) and the Patch Sensors
created correctly or Patch
E020- (UN43/J4007, UN44, J4006). 7.Replace the Drum
Sensor error
0250 Unit (C) 8.Replace the Registration Patch Sensor
High density for the target
Unit 9 Replace the ITB Unit. 10. Check conduction
at patch detection
of the fuses (FU5, FU8) in the DC Controller PCB
(UN09). 11. Replace the Primary Transfer High
Voltage PCB (UN04) 12. Replace the Developing
High Voltage PCB (UN07) 13. Replace the Primary
Charging High Voltage PCB (UN06) 14. Replace
the Auxiliary High Voltage PCB (UN08) 15.
Replace the Replace the DC Controller PCB
(UN09)
1. Check the patch shape. 2. Clean the high
voltage contact point with dry wiping or air blower.
3. Check the harness/connector between the DC
Controller (UN09) and the High Voltage PCB.
Between the DC Controller PCB (UN09/ J21) and
the Primary Charging High Voltage PCB (UN06/
ATR patch failed to be J441, J442) Between the DC Controller PCB
created correctly or Patch (UN09/ J21, J22) and the Developing High Voltage
E020-
Sensor error PCB (UN07/ J451, J452) Between the DC
0260
High density for the target Controller PCB (UN09/ J19) and the Auxiliary High
at patch detection Voltage PCB (UN08/J461, J462) Between the DC
Controller PCB (J205) and the Primary Transfer
High Voltage PCB (UN04/J1001) 4. Replace the
Drum Unit (C) 5. Replace the Registration Patch
Sensor Unit 6. Replace the ITB Unit. 7. Check
conduction of the fuses (FU5, FU8) in the DC
Controller PCB (UN09). 8. Replace the Primary
17

Transfer High Voltage PCB (UN04) 9. Replace the


Developing High Voltage PCB (UN07) 10. Replace
the Primary Charging High Voltage PCB (UN06)
11. Replace the Auxiliary High Voltage PCB
(UN08) 12. Replace the DC Controller PCB (UN09)
1. Check if the Drum Unit (C) is installed. 2. Check
ATR Sensor (C) error or
the Drum Unit Relay PCB (C) (UN28) 3. Check the
toner supply error
Drum Unit Memory PCB (C) (UN32) 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0290 Sensor (C) detection value
(UN09/ J25) and the Drum Unit Relay PCB (C)
is the specified value or
(UN28). 5. Replace the Drum Unit (C). 6. Replace
lower.
the DC Controller PCB (UN09)
1. Check if the Drum Unit (C) is installed. 2. Check
ATR Sensor (C) error or
the Drum Unit Relay PCB (C) (UN28) 3. Check the
toner supply error
Drum Unit Memory PCB (C) (UN32) 4. Check the
E020- The average of ATR
harness/connector between the DC Controller PCB
0291 Sensor (C) detection value
(UN09/ J25) and the Drum Unit Relay PCB (C)
is the specified value or
(UN28). 5. Replace the Drum Unit (C). 6. Replace
higher.
the DC Controller PCB (UN09)

Code Description Remedy


1. Check if the Drum Unit (C) is installed. 2.
ATR Sensor (C) error or toner
Check the Drum Unit Relay PCB (C) (UN28) 3.
supply error
Check the Drum Unit Memory PCB (C) (UN32) 4.
E020- The T/D ratio detected by the
Check the harness/connector between the DC
02B0 ATR Sensor (C) (UN41) is
Controller PCB (UN09/ J25) and the Drum Unit
equal to or higher than the
Relay PCB (C) (UN28). 5. Replace the Drum Unit
specified value (high density)
(C). 6. Replace the DC Controller PCB (UN09)
ATR Sensor (C) error or toner
Overload of the motor or motor failure 1. Check
supply error
conduction of FU9 on the DC Controller PCB
Error in detected delta T/D
(UN09). 2. Check the harness/connector
E020- ratio The T/D ratio detected
between the DC Controller PCB (UN09/J24) and
02B1 by the ATR Sensor (C)
PS08. 3. Replace the DC Controller PCB (UN09)
(UN41) is equal to or lower
4. Check the Hopper Unit (C). 5. Replace the
than the specified value (light
Hopper Unit (C).
density)
ATR Sensor (Bk) error or 1. Check if the Drum Unit (Bk) is installed. 2.
toner supply error Check the Drum Unit Relay PCB (Bk) (UN29) 3.
E020- Error in detected TD ratio. Check the Drum Unit Memory PCB (Bk) (UN33)
0320 The average of ATR 4. Check the harness/connector between the DC
reference value is the Controller PCB (UN09/ J25) and the Drum Unit
specified value or lower at the Relay PCB (Bk) (UN29). 5. Replace the Drum
18

time of ATR Sensor (Bk) Unit (Bk). 6. Replace the DC Controller PCB
initialization. (UN09)
ATR Sensor (Bk) error or 1. Check if the Drum Unit (Bk) is installed. 2.
toner supply error Check the Drum Unit Relay PCB (Bk) (UN29) 3.
Error in detected TD ratio. Check the Drum Unit Memory PCB (Bk) (UN33)
E020- The average of ATR 4. Check the harness/connector between the DC
0330 reference value is the Controller PCB (UN09/ J25) and the Drum Unit
specified value or higher at Relay PCB (Bk) (UN29). 5. Replace the Drum
the time of ATR Sensor (Bk) Unit (Bk). 6. Replace the DC Controller PCB
initialization. (UN09)
1. Check if the Drum Unit (Bk) is installed. 2.
Check the Drum Unit Relay PCB (Bk) (UN29) 3.
ATR Sensor (Bk) error or
Check the Drum Unit Memory PCB (Bk) (UN33)
toner supply error
E020- 4. Check the harness/connector between the DC
Unable to adjust the control
0340 Controller PCB (UN09/ J25) and the Drum Unit
voltage at the time of ATR
Relay PCB (Bk) (UN29). 5. Replace the Drum
Sensor (Bk) initialization.
Unit (Bk). 6. Replace the DC Controller PCB
(UN09)
1. Check if the Drum Unit (Bk) is installed. 2.
Check the Drum Unit Relay PCB (Bk) (UN29) 3.
ATR Sensor (Bk) error or
Check the Drum Unit Memory PCB (Bk) (UN33)
toner supply error
E020- 4. Check the harness/connector between the DC
Unable to adjust the control
0341 Controller PCB (UN09/ J25) and the Drum Unit
voltage at the time of ATR
Relay PCB (Bk) (UN29). 5. Replace the Drum
Sensor (Bk) initialization.
Unit (Bk). 6. Replace the DC Controller PCB
(UN09)
1. Clean the scanner’s window. 2. Use your hand
to check if the shutter of the Registration Patch
Sensor Unit can be open. 3. Check if the window
of the Patch Sensor (UN43/ UN44) is soiled. 4.
Check scar on the ITB. 5. Check movement of
the Registration Shutter Solenoid (SL02).
COPIER > FUNCTION > PART-CHK > SL to
ATR patch failed to be
move SL02 6. Check the harness/connector
created correctly or Patch
E020- between the DC Controller PCB (UN09/J12) and
Sensor error
0350 the Patch Sensors (UN43/J4007, UN44, J4006).
High density for the target at
7.Replace the Drum Unit (Bk) 8.Replace the
patch detection
Registration Patch Sensor Unit 9 Replace the
ITB Unit. 10. Check conduction of the fuses
(FU5, FU8) in the DC Controller PCB (UN09). 11.
Replace the Primary Transfer High Voltage PCB
(UN04) 12. Replace the Developing High Voltage
PCB (UN07) 13. Replace the Primary Charging
High Voltage PCB (UN06) 14. Replace the
19

Auxiliary High Voltage PCB (UN08) 15. Replace


the Replace the DC Controller PCB (UN09)
1. Check the patch shape. 2. Clean the high
voltage contact point with dry wiping or air
blower. 3. Check the harness/connector between
the DC Controller (UN09) and the High Voltage
PCB. Between the DC Controller PCB (UN09/
J21) and the Primary Charging High Voltage
PCB (UN06/ J441, J442) Between the DC
Controller PCB (UN09/ J21, J22) and the
Developing High Voltage PCB (UN07/ J451,
J452) Between the DC Controller PCB (UN09/
ATR patch failed to be
J19) and the Auxiliary High Voltage PCB
created correctly or Patch
E020- (UN08/J461, J462) Between the DC Controller
Sensor error
0360 PCB (J205) and the Primary Transfer High
High density for the target at
Voltage PCB (UN04/J1001) 4. Replace the Drum
patch detection
Unit (Bk) 5. Replace the Registration Patch
Sensor Unit 6. Replace the ITB Unit. 7. Check
conduction of the fuses (FU5, FU8) in the DC
Controller PCB (UN09). 8. Replace the Primary
Transfer High Voltage PCB (UN04) 9. Replace
the Developing High Voltage PCB (UN07) 10.
Replace the Primary Charging High Voltage PCB
(UN06) 11. Replace the Auxiliary High Voltage
PCB (UN08) 12. Replace the DC Controller PCB
(UN09)
1. Check if the Drum Unit (Bk) is installed. 2.
Check the Drum Unit Relay PCB (Bk) (UN29) 3.
ATR Sensor (Bk) error or
Check the Drum Unit Memory PCB (Bk) (UN33)
toner supply error
E020- 4. Check the harness/connector between the DC
The average of ATR Sensor
0390 Controller PCB (UN09/ J25) and the Drum Unit
(Bk) detection value is the
Relay PCB (Bk) (UN29). 5. Replace the Drum
specified value or lower.
Unit (Bk). 6. Replace the DC Controller PCB
(UN09)
1. Check if the Drum Unit (Bk) is installed. 2.
Check the Drum Unit Relay PCB (Bk) (UN29) 3.
ATR Sensor (Bk) error or
Check the Drum Unit Memory PCB (Bk) (UN33)
toner supply error
E020- 4. Check the harness/connector between the DC
The average of ATR Sensor
0391 Controller PCB (UN09/ J25) and the Drum Unit
(Bk) detection value is the
Relay PCB (Bk) (UN29). 5. Replace the Drum
specified value or higher.
Unit (Bk). 6. Replace the DC Controller PCB
(UN09)
E020- ATR Sensor (Bk) error or 1. Check if the Drum Unit (Bk) is installed. 2.
03B0 toner supply error Check the Drum Unit Relay PCB (Bk) (UN29) 3.
20

The T/D ratio detected by the Check the Drum Unit Memory PCB (Bk) (UN33)
ATR Sensor (Bk) (UN42) is 4. Check the harness/connector between the DC
equal to or higher than the Controller PCB (UN09/ J25) and the Drum Unit
specified value (high density) Relay PCB (Bk) (UN29). 5. Replace the Drum
Unit (Bk). 6. Replace the DC Controller PCB
(UN09)
ATR Sensor (Bk) error or
Overload of the motor or motor failure 1. Check
toner supply error
conduction of FU9 on the DC Controller PCB
Error in detected delta T/D
(UN09). 2. Check the harness/connector
E020- ratio The T/D ratio detected
between the DC Controller PCB (UN09/J26) and
03B1 by the ATR Sensor (Bk)
PS09 3. Replace the DC Controller PCB (UN09)
(UN42) is equal to or lower
4. Check the Hopper Unit (Bk). 5. Replace the
than the specified value (light
Hopper Unit (Bk).
density)
1. Clean the scanner’s window. 2. Use your hand
to check if the shutter of the Registration Patch
Sensor Unit can be open. 3. Check if the window
of the Patch Sensor (UN43/ UN44) is soiled. 4.
Check scar on the ITB. 5. Check movement of
the Registration Shutter Solenoid (SL02).
COPIER > FUNCTION > PART-CHK > SL to
move SL02 6. Check the harness/connector
Abnormal Y color patch between the DC Controller PCB (UN09/J12) and
E020- reading value the Patch Sensors (UN43/J4007, UN44, J4006).
1050 Dark patch although setting 0 7.Replace the Drum Unit (Y) 8.Replace the
for the patch level Registration Patch Sensor Unit 9 Replace the
ITB Unit. 10. Check conduction of the fuses
(FU5, FU8) in the DC Controller PCB (UN09). 11.
Replace the Primary Transfer High Voltage PCB
(UN04) 12. Replace the Developing High Voltage
PCB (UN07) 13. Replace the Primary Charging
High Voltage PCB (UN06) 14. Replace the
Auxiliary High Voltage PCB (UN08) 15. Replace
the Replace the DC Controller PCB (UN09)
1. Check the patch shape. 2. Clean the high
voltage contact point with dry wiping or air
blower. 3. Check the harness/connector between
the DC Controller (UN09) and the High Voltage
Abnormal Y color patch
PCB. Between the DC Controller PCB (UN09/
E020- reading value
J21) and the Primary Charging High Voltage
1060 Light patch although setting 7
PCB (UN06/ J441, J442) Between the DC
for patch level
Controller PCB (UN09/ J21, J22) and the
Developing High Voltage PCB (UN07/ J451,
J452) Between the DC Controller PCB (UN09/
J19) and the Auxiliary High Voltage PCB
21

(UN08/J461, J462) Between the DC Controller


PCB (J205) and the Primary Transfer High
Voltage PCB (UN04/J1001) 4. Replace the Drum
Unit (Y) 5. Replace the Registration Patch
Sensor Unit 6. Replace the ITB Unit. 7. Check
conduction of the fuses (FU5, FU8) in the DC
Controller PCB (UN09). 8. Replace the Primary
Transfer High Voltage PCB (UN04) 9. Replace
the Developing High Voltage PCB (UN07) 10.
Replace the Primary Charging High Voltage PCB
(UN06) 11. Replace the Auxiliary High Voltage
PCB (UN08) 12. Replace the DC Controller PCB
(UN09)
1. Clean the scanner’s window. 2. Use your hand
to check if the shutter of the Registration Patch
Sensor Unit can be open. 3. Check if the window
of the Patch Sensor (UN43/ UN44) is soiled. 4.
Check scar on the ITB. 5. Check movement of
the Registration Shutter Solenoid (SL02).
COPIER > FUNCTION > PART-CHK > SL to
move SL02 6. Check the harness/connector
Abnormal M color patch between the DC Controller PCB (UN09/J12) and
E020- reading value the Patch Sensors (UN43/J4007, UN44, J4006).
1150 Dark patch although setting 0 7.Replace the Drum Unit (M) 8.Replace the
for the patch level Registration Patch Sensor Unit 9 Replace the
ITB Unit. 10. Check conduction of the fuses
(FU5, FU8) in the DC Controller PCB (UN09). 11.
Replace the Primary Transfer High Voltage PCB
(UN04) 12. Replace the Developing High Voltage
PCB (UN07) 13. Replace the Primary Charging
High Voltage PCB (UN06) 14. Replace the
Auxiliary High Voltage PCB (UN08) 15. Replace
the Replace the DC Controller PCB (UN09)
Code Description Remedy
1. Check the patch shape. 2. Clean the high
voltage contact point with dry wiping or air
blower. 3. Check the harness/connector between
Abnormal M color patch
the DC Controller (UN09) and the High Voltage
reading value
PCB. Between the DC Controller PCB (UN09/
E020- Light patch although setting 7
J21) and the Primary Charging High Voltage
1160 for patch level (unable to fit in
PCB (UN06/ J441, J442) Between the DC
the target between 550 and
Controller PCB (UN09/ J21, J22) and the
640)
Developing High Voltage PCB (UN07/ J451,
J452) Between the DC Controller PCB (UN09/
J19) and the Auxiliary High Voltage PCB
22

(UN08/J461, J462) Between the DC Controller


PCB (J205) and the Primary Transfer High
Voltage PCB (UN04/J1001) 4. Replace the Drum
Unit (M) 5. Replace the Registration Patch
Sensor Unit 6. Replace the ITB Unit. 7. Check
conduction of the fuses (FU5, FU8) in the DC
Controller PCB (UN09). 8. Replace the Primary
Transfer High Voltage PCB (UN04) 9. Replace
the Developing High Voltage PCB (UN07) 10.
Replace the Primary Charging High Voltage PCB
(UN06) 11. Replace the Auxiliary High Voltage
PCB (UN08) 12. Replace the DC Controller PCB
(UN09)
1. Clean the scanner’s window. 2. Use your hand
to check if the shutter of the Registration Patch
Sensor Unit can be open. 3. Check if the window
of the Patch Sensor (UN43/ UN44) is soiled. 4.
Check scar on the ITB. 5. Check movement of
the Registration Shutter Solenoid (SL02).
COPIER > FUNCTION > PART-CHK > SL to
move SL02 6. Check the harness/connector
Abnormal C color patch between the DC Controller PCB (UN09/J12) and
E020- reading value the Patch Sensors (UN43/J4007, UN44, J4006).
1250 Dark patch although setting 0 7.Replace the Drum Unit (C) 8.Replace the
for the patch level Registration Patch Sensor Unit 9 Replace the
ITB Unit. 10. Check conduction of the fuses
(FU5, FU8) in the DC Controller PCB (UN09). 11.
Replace the Primary Transfer High Voltage PCB
(UN04) 12. Replace the Developing High Voltage
PCB (UN07) 13. Replace the Primary Charging
High Voltage PCB (UN06) 14. Replace the
Auxiliary High Voltage PCB (UN08) 15. Replace
the Replace the DC Controller PCB (UN09)
1. Check the patch shape. 2. Clean the high
voltage contact point with dry wiping or air
blower. 3. Check the harness/connector between
Abnormal C color patch the DC Controller (UN09) and the High Voltage
reading value PCB. Between the DC Controller PCB (UN09/
E020- Light patch although setting 7 J21) and the Primary Charging High Voltage
1260 for patch level (unable to fit in PCB (UN06/ J441, J442) Between the DC
the target between 550 and Controller PCB (UN09/ J21, J22) and the
640) Developing High Voltage PCB (UN07/ J451,
J452) Between the DC Controller PCB (UN09/
J19) and the Auxiliary High Voltage PCB
(UN08/J461, J462) Between the DC Controller
23

PCB (J205) and the Primary Transfer High


Voltage PCB (UN04/J1001) 4. Replace the Drum
Unit (C) 5. Replace the Registration Patch
Sensor Unit 6. Replace the ITB Unit. 7. Check
conduction of the fuses (FU5, FU8) in the DC
Controller PCB (UN09). 8. Replace the Primary
Transfer High Voltage PCB (UN04) 9. Replace
the Developing High Voltage PCB (UN07) 10.
Replace the Primary Charging High Voltage PCB
(UN06) 11. Replace the Auxiliary High Voltage
PCB (UN08) 12. Replace the DC Controller PCB
(UN09)
1. Clean the scanner’s window. 2. Use your hand
to check if the shutter of the Registration Patch
Sensor Unit can be open. 3. Check if the window
of the Patch Sensor (UN43/ UN44) is soiled. 4.
Check scar on the ITB. 5. Check movement of
the Registration Shutter Solenoid (SL02).
COPIER > FUNCTION > PART-CHK > SL to
move SL02 6. Check the harness/connector
Abnormal Bk color patch between the DC Controller PCB (UN09/J12) and
E020- reading value the Patch Sensors (UN43/J4007, UN44, J4006).
1350 Dark patch although setting 0 7.Replace the Drum Unit (Bk) 8.Replace the
for the patch level Registration Patch Sensor Unit 9 Replace the
ITB Unit. 10. Check conduction of the fuses
(FU5, FU8) in the DC Controller PCB (UN09). 11.
Replace the Primary Transfer High Voltage PCB
(UN04) 12. Replace the Developing High Voltage
PCB (UN07) 13. Replace the Primary Charging
High Voltage PCB (UN06) 14. Replace the
Auxiliary High Voltage PCB (UN08) 15. Replace
the Replace the DC Controller PCB (UN09)
1. Check the patch shape. 2. Clean the high
voltage contact point with dry wiping or air
blower. 3. Check the harness/connector between
the DC Controller (UN09) and the High Voltage
PCB. Between the DC Controller PCB (UN09/
Abnormal Bk color patch
J21) and the Primary Charging High Voltage
E020- reading value
PCB (UN06/ J441, J442) Between the DC
1360 Light patch although setting 7
Controller PCB (UN09/ J21, J22) and the
for patch level
Developing High Voltage PCB (UN07/ J451,
J452) Between the DC Controller PCB (UN09/
J19) and the Auxiliary High Voltage PCB
(UN08/J461, J462) Between the DC Controller
PCB (J205) and the Primary Transfer High
24

Voltage PCB (UN04/J1001) 4. Replace the Drum


Unit (Bk) 5. Replace the Registration Patch
Sensor Unit 6. Replace the ITB Unit. 7. Check
conduction of the fuses (FU5, FU8) in the DC
Controller PCB (UN09). 8. Replace the Primary
Transfer High Voltage PCB (UN04) 9. Replace
the Developing High Voltage PCB (UN07) 10.
Replace the Primary Charging High Voltage PCB
(UN06) 11. Replace the Auxiliary High Voltage
PCB (UN08) 12. Replace the DC Controller PCB
(UN09)
Possible cause is overload or rotation failure of
the motor due to an electrical trouble 1. Check
the Main Drive Unit (turn the unit by hand to see
if it rotates) Replace the Main Drive Unit when
the unit failed to rotate When the unit rotates 2.
CL Developing Motor startup
Check failure of the harness between the
error
Developing Motor (M03/J6026) and the DC
E021- After 700 msec since the
Controller PCB (UN09/J210W) (trapped cable,
0001 startup, the speed failed to be
open circuit, connector disconnection) 3. Check
OK for 500 consecutive
conduction of the fuse (FU7) in the DC Controller
msec.
PCB (UN09) When the fuse is not blown out 4-1.
Replace the Developing Motor (M03) 5-1.
Replace the DC Controller PCB (UN09). When
the fuse is blown out 4-2. Replace the DC
Controller PCB (UN09).
Possible cause is overload or rotation failure of
the motor due to an electrical trouble 1. Check
the Main Drive Unit (turn the unit by hand to see
if it rotates) Replace the Main Drive Unit when
the unit failed to rotate When the unit rotates 2.
CL Developing Motor lock Check failure of the harness between the
detection Developing Motor (M03/J6026) and the DC
E021-
Since the startup, the FG Controller PCB (UN09/J210W) (trapped cable,
0003
signal failed to be turned ON open circuit, connector disconnection) 3. Check
for 300msec. conduction of the fuse (FU7) in the DC Controller
PCB (UN09) When the fuse is not blown out 4-1.
Replace the Developing Motor (M03) 5-1.
Replace the DC Controller PCB (UN09). When
the fuse is blown out 4-2. Replace the DC
Controller PCB (UN09).
Developing screw rotation Possible cause: The screw is not rotating due to
E021- detection failure in the coupling between the main body
0020 Error in the difference and the Developing Assembly, or the value of
between the maximum and ATR Sensor (Y) (UN39) failed to be read due to
25

the minimum of ATR Sensor an electrical trouble. 1. Remove the Drum Unit
(Y) detection value. (Y) and check no damage. (Replace the Drum
Unit (Y) if defective) 2. Lift the pressure lever
after the Drum Unit (Y) is pushed all the way in.
3. Check failure of the harness between the
Drum Unit (Y) and the DC Controller PCB
(UN09/J25) (trapped cable, open circuit,
connector disconnection) 4.Check the Drum Unit
Relay PCB (Y) (UN26) (Soil/ deformation/
damage) 5. Check the Drum Unit Memory PCB
(M) (UN30) (Soil/ damage) 6.Replace the Drum
Unit (Y) 7. Replace the DC Controller PCB
(UN09). 8. Replace the Main Drive Unit
Possible cause: The screw is not rotating due to
failure in the coupling between the main body
and the Developing Assembly, or the value of
ATR Sensor (M) (UN40) failed to be read due to
an electrical trouble. 1. Remove the Drum Unit
(M) and check no damage. (Replace the Drum
Developing screw rotation
Unit (M) if defective) 2. Lift the pressure lever
detection
after the Drum Unit (M) is pushed all the way in.
E021- Error in the difference
3. Check failure of the harness between the
0120 between the maximum and
Drum Unit (M) and the DC Controller PCB
the minimum of ATR Sensor
(UN09/J25) (trapped cable, open circuit,
(M) detection value.
connector disconnection) 4.Check the Drum Unit
Relay PCB (M) (UN27) (Soil/ deformation/
damage) 5. Check the Drum Unit Memory PCB
(M) (UN31) (Soil/ damage) 6.Replace the Drum
Unit (M) 7. Replace the DC Controller PCB
(UN09). 8. Replace the Main Drive Unit
Possible cause: The screw is not rotating due to
failure in the coupling between the main body
and the Developing Assembly, or the value of
ATR Sensor (C)(UN41) failed to be read due to
an electrical trouble. 1. Remove the Drum Unit
Developing screw rotation
(C) and check no damage. (Replace the Drum
detection
Unit (C) if defective) 2. Lift the pressure lever
E021- Error in the difference
after the Drum Unit (C) is pushed all the way in.
0220 between the maximum and
3.Check failure of the harness between the Drum
the minimum of ATR Sensor
Unit (C) and the DC Controller PCB (UN09/J25)
(C) detection value.
(trapped cable, open circuit, connector
disconnection) 4.Check the Drum Unit Relay
PCB (C) (UN28) (Soil/ deformation/ damage)
5.Check the Drum Unit Memory PCB (C) (UN32)
(Soil/ damage) 6.Replace the Drum Unit (C). 7.
26

Replace the DC Controller PCB (UN09). 8.


Replace the Main Drive Unit
Possible cause: The screw is not rotating due to
failure in the coupling between the main body
and the Developing Assembly, or the value of
ATR Sensor (Bk) (UN42) failed to be read due to
an electrical trouble 1. Remove the Drum Unit
(Bk) and check no damage. (Replace the Drum
Developing screw rotation
Unit (Bk) if defective) 2. Lift the pressure lever
detection
after the Drum Unit (Bk) is pushed all the way in.
E021- Error in the difference
3. Check failure of the harness between the
0320 between the maximum and
Drum Unit (Bk) and the DC Controller PCB
the minimum of ATR Sensor
(UN09/J25) (trapped cable, open circuit,
(Bk) detection value.
connector disconnection) 4.Check the Drum Unit
Relay PCB (Bk) (UN29) (Soil/ deformation/
damage) 5. Check the Drum Unit Memory PCB
(Bk) (UN33) (Soil/ damage) 6.Replace the Drum
Unit (Bk). 7. Replace the DC Controller PCB
(UN09). 8. Replace the Main Drive Unit
Error in the Shutter Motor or the Laser Shutter
Sensor 1.COPIER > FUNCTION > PART-CHK >
MTR; move M05 When it works 2-1. Check the
Error in detection of abnormal harness between the DC Controller (UN09/ J11)
opening/closing of the Laser and the Laser Shutter Sensor (PS05) 3-1. Check
Shutter condition of the Laser Shutter 4-1. Check the
E022- At the Dustproof Shutter Laser Shutter Sensor (PS05) in the Main Drive 5-
0000 open/close control, the 1. Replace the Main Drive When it does not work
sensor fails to detect although 2-2. Check the harness between the DC
the specified time has Controller (UN09/ J31) and the Developing
passed. Disengagement Motor (M05) 3-2. Check
conduction of the fuse (FU6) in the DC Controller
(UN09) 4-2. Replace the Laser Shutter Motor
(M05) 5-2. Replace the Main Drive
Possible cause: overload with the motor or motor
failure 1. Check conduction with FU2 on the DC
Toner Supply Motor (Y) lock Controller PCB (UN09) 2. Check the
E025- detection harness/connector between the DC Controller
0000 Failed to detect rotation after PCB (UN09/ J23) and PS06. 3. Replace the DC
turning ON the motor. Controller PCB (UN09) Check the harness
toward the sensor 4. Check the Hopper Unit (Y)
5. Replace the Hopper Unit (Y).
Toner Container Motor (Y) Overload of the motor or motor failure 1. Check if
E025-
lock detection the Toner Bottle (Y) is installed 2. Check the
0010
Error in the current value after harness/connector between the DC Controller
27

turning ON the motor. PCB (UN09) and the Toner Container Motor (Y)
(M07) 3. Check conduction of FU1 in the DC
Controller PCB (UN09) 4. Replace the DC
Controller PCB (UN09) 5. Replace the Hopper
Unit (Y)
Detection of short-circuit with
Toner Container Motor
(Y)FET
E025-
Error in element in the DC 1.Replace the DC Controller PCB (UN09)
0020
Controller PCB Error in the
current value after turning
OFF the motor.

Code Description Remedy


Detection of short-circuit
Short-circuit failure of the Toner Bottle Motor or error
with Toner Container
in element in the DC Controller PCB 1. Check the
Motor (Y) GND
E025- harness between the DC Controller (UN09/J23) and
After turning ON the
0030 the Toner Container Motor (Y) (M07) 2. Replace the
motor, the current value
DC Controller PCB (UN09) 3. Replace the Hopper Unit
is a certain value or
(Y)
lower.
Toner Supply Motor (M)
Overload of the motor or motor failure 1. Check
lock detection
conduction with FU2 on the DC Controller PCB
The Rotation Sensor
E025- (UN09) 2. Check the harness/connector between the
does not detect rotation
0100 DC Controller PCB (UN09/J24) and PS07. 3. Replace
although 5 sec has
the DC Controller PCB (UN09) 4. Check the Hopper
passed since the motor
Unit (M). 5. Replace the Hopper Unit (M).
was turned ON
Overload of the motor or motor failure 1. Check if the
Toner Container Motor Toner Bottle (M) is installed 2. Check the
(M) lock detection harness/connector between the DC Controller PCB
E025-
Error in the current (UN09) and the Toner Container Motor (M) (M09) 3.
0110
value after turning ON Check conduction of FU1 in the DC Controller PCB
the motor. (UN09) 4. Replace the DC Controller PCB (UN09) 5.
Replace the Hopper Unit (M)
Detection of short-circuit
with Toner Container
Motor (M)FET
E025- Error in element in the DC Controller PCB 1.Replace
Error in element in the
0120 the DC Controller PCB (UN09)
DC Controller PCB Error
in the current value after
turning OFF the motor.
28

Detection of short-circuit
Short-circuit failure of the Toner Bottle Motor or error
with Toner Container
in element in the DC Controller PCB 1. Check the
Motor (M) GND
E025- harness between the DC Controller (UN09/J24) and
After turning ON the
0130 the Toner Container Motor (M) (M09) 2. Replace the
motor, the current value
DC Controller PCB (UN09) 3. Replace the Hopper Unit
is a certain value or
(M)
lower.
Toner Supply Motor (C)
lock detection Overload of the motor or motor failure 1. Check
After turning ON the conduction of FU9 on the DC Controller PCB (UN09).
E025- motor, the rotation 2. Check the harness/connector between the DC
0200 sensor does not detect Controller PCB (UN09/J24) and PS08. 3. Replace the
although a specified DC Controller PCB (UN09) 4. Check the Hopper Unit
period of time has (C). 5. Replace the Hopper Unit (C).
passed.
Overload of the motor or motor failure 1. Check if the
Toner Container Motor Toner Bottle (C) is installed 2. Check the
(C) lock detection harness/connector between the DC Controller PCB
E025-
Error in the current (UN09) and the Toner Container Motor (C) (M11) 3.
0210
value after turning ON Check conduction of FU3 in the DC Controller PCB
the motor. (UN09) 4. Replace the DC Controller PCB (UN09) 5.
Replace the Hopper Unit (C)
Detection of short-circuit
with Toner Container
Motor (C)FET
E025- Error in element in the DC Controller PCB 1.Replace
Error in element in the
0220 the DC Controller PCB (UN09)
DC Controller PCB Error
in the current value after
turning OFF the motor.
Detection of short-circuit
Short-circuit failure of the Toner Bottle Motor or error
with Toner Container
in element in the DC Controller PCB 1. Check the
Motor (C) GND
E025- harness between the DC Controller (UN09/J24) and
After turning ON the
0230 the Toner Container Motor (C) (M11) 2. Replace the
motor, the current value
DC Controller PCB (UN09) 3. Replace the Hopper Unit
is a certain value or
(C)
lower.
Toner Supply Motor (Bk)
Overload of the motor or motor failure 1. Check
lock detection
conduction of FU9 on the DC Controller PCB (UN09).
The Rotation Sensor
E025- 2. Check the harness/connector between the DC
does not detect rotation
0300 Controller PCB (UN09/J26) and PS09 3. Replace the
although 5 sec has
DC Controller PCB (UN09) 4. Check the Hopper Unit
passed since the motor
(Bk). 5. Replace the Hopper Unit (Bk).
was turned ON
29

Overload of the motor or motor failure 1. Check if the


Toner Container Motor Toner Bottle (Bk) is installed 2. Check the
(Bk) lock detection harness/connector between the DC Controller PCB
E025-
Error in the current (UN09) and the B Toner Container Motor (Bk)(M13) 3.
0310
value after turning ON Check conduction of FU3 in the DC Controller PCB
the motor. (UN09) 4. Replace the DC Controller PCB (UN09) 5.
Replace the Hopper Unit (Bk)
Detection of short-circuit
with Toner Container
Motor (Bk)FET
E025- Error in element in the DC Controller PCB 1.Replace
Error in element in the
0320 the DC Controller PCB (UN09)
DC Controller PCB Error
in the current value after
turning OFF the motor.
Detection of short-circuit
Short-circuit failure of the Toner Bottle Motor or error
with Toner Container
in element in the DC Controller PCB 1. Check the
Motor (Bk) GND
E025- harness between the DC Controller (UN09/J26) and
After turning ON the
0330 the Toner Container Motor (Bk) (M13) 2. Replace the
motor, the current value
DC Controller PCB (UN09) 3. Replace the Hopper Unit
is a certain value or
(Bk)
lower
ASSIST Counter failed
to work
E032-
Detection of short-circuit Check the cable (to see if it’s disconnected)
0001
with the Count Pulse
Signal
Error in Lift Motor or Lifter Sensor 1. While Cassette 1
is removed, turn ON the power and then insert
Cassette 1. When there is operation sound of the
motor 1-1. Check the harness/connector between the
DC Controller (UN09/J13) and the Cassette 1 Lifter
Sensor (PS12) 2-1. Check if the Cassette 1 Lifter
Sensor (PS12) is installed. 3-1. Extend the Sensor
Cassette 1 Lifter error
Flag of the Cassette 1 Lifter Sensor (PS12) by approx.
Unable to detect the lift-
E040- 1.5 mm with Plastic Film, etc. 4-1. Check the condition
up completion position
0002 of the gear at the host machine side (to see if there is
within 4.5 sec after lift-
missing or swing with the gear) 5-1. Replace the
up was started
Cassette 1 Lifter Sensor (PS12) 6-1. Replace the DC
Controller PCB (UN09) When there is no operation
sound of the motor 1-2. Check the harness/connector
between the DC Controller (UN09/J13) and the
Cassette 1 Lifter Motor (M14) 2-2. Check conduction
of the fuse (FU2) of the DC Controller (UN09) 3-2.
Check the condition of the gear at the host machine
30

side (to see if there is something missing or swing with


the gear) 4-2. Check the Cassette 1 Lifter Motor (M14)
5-2. Replace the DC Controller (UN09)

Code Description Remedy


Error in output of charging high voltage, Drum Unit
error or environment control error 1. COPIER >
DISPLAY > ANALOG; check if the TEMP value
and the HUM value are matched with the
environment temperature. When the values are
dramatically mismatched (Lager than 15degrees
Error in detection of
Celsius) 2-1. Check the harness and connector
abnormal Y charging AC
between the DC Controller (UN09/ J206) and the
current value
Environment Sensor (UN45) 3-1. Replace the
E065- During the paper interval
Environment Sensor (UN45) 4-1. Replace the DC
0000 simple discharge current
Controller (UN09) When the values are matched 2-
control, a current value that
2. Check the state of the charging high voltage
is higher than the target of
contact point 3-2. Replace the Drum Unit (Y) 4-2.
500[uA] is detected
Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary
Charging High Voltage PCB (UN06/ J441, J442) 5-
2. Replace the Primary Charging High Voltage
PCB (UN06) 6-2. Replace the DC Controller PCB
(UN09)
Error in output of charging high voltage, Drum Unit
error or environment control error 1. COPIER >
DISPLAY > ANALOG; check if the TEMP value
and the HUM value are matched with the
environment temperature. When the values are
dramatically mismatched (Lager than 15degrees
Error in detection of
Celsius) 2-1. Check the harness and connector
abnormal Y charging AC
between the DC Controller (UN09/ J206) and the
current value
Environment Sensor (UN45) 3-1. Replace the
E065- During the paper interval
Environment Sensor (UN45) 4-1. Replace the DC
0000 simple discharge current
Controller (UN09) When the values are matched 2-
control, a current value that
2. Check the state of the charging high voltage
is higher than the target of
contact point 3-2. Replace the Drum Unit (Y) 4-2.
500[uA] is detected
Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary
Charging High Voltage PCB (UN06/ J441, J442) 5-
2. Replace the Primary Charging High Voltage
PCB (UN06) 6-2. Replace the DC Controller PCB
(UN09)
31

Error in output of charging high voltage, Drum Unit


error or environment control error 1. COPIER >
DISPLAY > ANALOG; check if the TEMP value
and the HUM value are matched with the
environment temperature. When the values are
dramatically mismatched (Lager than 15degrees
Error in detection of
Celsius) 2-1. Check the harness and connector
abnormal M charging AC
between the DC Controller (UN09/ J206) and the
current value
Environment Sensor (UN45) 3-1. Replace the
E065- During the paper interval
Environment Sensor (UN45) 4-1. Replace the DC
0001 simple discharge current
Controller (UN9) When the values are matched 2-
control, a current value that
2. Check the state of the charging high voltage
is higher than the target of
contact point 3-2. Replace the Drum Unit (M) 4-2.
500[uA] is detected
Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary
Charging High Voltage PCB (UN06/ J441, J442) 5-
2. Replace the Primary Charging High Voltage
PCB (UN06) 6-2. Replace the DC Controller PCB
(UN09)
Error in output of charging high voltage, Drum Unit
error or environment control error 1. COPIER >
DISPLAY > ANALOG; check if the TEMP value
and the HUM value are matched with the
environment temperature. When the values are
dramatically mismatched (Lager than 15degrees
Error in detection of
Celsius) 2-1. Check the harness and connector
abnormal M charging AC
between the DC Controller (UN09/ J206) and the
current value
Environment Sensor (UN45) 3-1. Replace the
E065- During the paper interval
Environment Sensor (UN45) 4-1. Replace the DC
0001 simple discharge current
Controller (UN9) When the values are matched 2-
control, a current value that
2. Check the state of the charging high voltage
is higher than the target of
contact point 3-2. Replace the Drum Unit (M) 4-2.
500[uA] is detected
Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary
Charging High Voltage PCB (UN06/ J441, J442) 5-
2. Replace the Primary Charging High Voltage
PCB (UN06) 6-2. Replace the DC Controller PCB
(UN09)
Error in detection of Error in output of charging high voltage, Drum Unit
abnormal C charging AC error or environment control error 1. COPIER >
current value DISPLAY > ANALOG; check if the TEMP value
E065-
During the paper interval and the HUM value are matched with the
0002
simple discharge current environment temperature. When the values are
control, a current value that dramatically mismatched (Lager than 15degrees
is higher than the target of Celsius) 2-1. Check the harness and connector
32

500[uA] is detected between the DC Controller (UN09/ J206) and the


Environment Sensor (UN45) 3-1. Replace the
Environment Sensor (UN45) 4-1. Replace the DC
Controller (UN9) When the values are matched 2-
2. Check the state of the charging high voltage
contact point 3-2. Replace the Drum Unit (C) 4-2.
Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary
Charging High Voltage PCB (UN06/ J441, J442) 5-
2. Replace the Primary Charging High Voltage
PCB (UN06) 6-2. Replace the DC Controller PCB
(UN09)
Error in output of charging high voltage, Drum Unit
error or environment control error 1. COPIER >
DISPLAY > ANALOG; check if the TEMP value
and the HUM value are matched with the
environment temperature. When the values are
dramatically mismatched (Lager than 15degrees
Error in detection of
Celsius) 2-1. Check the harness and connector
abnormal C charging AC
between the DC Controller (UN09/ J206) and the
current value
Environment Sensor (UN45) 3-1. Replace the
E065- During the paper interval
Environment Sensor (UN45) 4-1. Replace the DC
0002 simple discharge current
Controller (UN9) When the values are matched 2-
control, a current value that
2. Check the state of the charging high voltage
is higher than the target of
contact point 3-2. Replace the Drum Unit (C) 4-2.
500[uA] is detected
Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary
Charging High Voltage PCB (UN06/ J441, J442) 5-
2. Replace the Primary Charging High Voltage
PCB (UN06) 6-2. Replace the DC Controller PCB
(UN09)
Error in output of charging high voltage, Drum Unit
error or environment control error 1. COPIER >
DISPLAY > ANALOG; check if the TEMP value
Error in detection of and the HUM value are matched with the
abnormal Bk charging AC environment temperature. When the values are
current value dramatically mismatched (Lager than 15degrees
E065- During the paper interval Celsius) 2-1. Check the harness and connector
0003 simple discharge current between the DC Controller (UN09/ J206) and the
control, a current value that Environment Sensor (UN45) 3-1. Replace the
is higher than the target of Environment Sensor (UN45) 4-1. Replace the DC
500[uA] is detected Controller (UN9) When the values are matched 2-
2. Check the state of the charging high voltage
contact point 3-2. Replace the Drum Unit (Bk). 4-2.
Check the harness and connector between the DC
33

Controller PCB (UN09/ J21) and the Primary


Charging High Voltage PCB (UN06/ J441, J442) 5-
2. Replace the Primary Charging High Voltage
PCB (UN06) 6-2. Replace the DC Controller PCB
(UN09)
Error in output of charging high voltage, Drum Unit
error or environment control error 1. COPIER >
DISPLAY > ANALOG; check if the TEMP value
and the HUM value are matched with the
environment temperature. When the values are
dramatically mismatched (Lager than 15degrees
Error in detection of
Celsius) 2-1. Check the harness and connector
abnormal Bk charging AC
between the DC Controller (UN09/ J206) and the
current value
Environment Sensor (UN45) 3-1. Replace the
E065- During the paper interval
Environment Sensor (UN45) 4-1. Replace the DC
0003 simple discharge current
Controller (UN9) When the values are matched 2-
control, a current value that
2. Check the state of the charging high voltage
is higher than the target of
contact point 3-2. Replace the Drum Unit (Bk). 4-2.
500[uA] is detected
Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary
Charging High Voltage PCB (UN06/ J441, J442) 5-
2. Replace the Primary Charging High Voltage
PCB (UN06) 6-2. Replace the DC Controller PCB
(UN09)
Error in the Primary Transfer High Voltage PCB,
Error in the Primary Transfer Roller (ITB Unit) 1.
Check failure of the harness between the Primary
Transfer High Voltage PCB (UN04/J1001) and the
DC Controller PCB (UN09/J205) (open circuit,
Error in M primary transfer trapped cable, connector disconnection). ->
abnormal detection Replace the harness if it is faulty 2. Check
E067-
When trying to apply the connection failure between the Primary Transfer
0001
specified voltage of 1500 [V] High Voltage PCB (UN04/J31) and the Primary
or higher Transfer Roller (Check that the connection is free
from open circuit or GND contact) 3. Replace the
Primary Transfer High Voltage PCB (UN04) 4.
Replace the ITB Unit 5. Replace the DC Controller
PCB (UN09). 6. Replace the Primary Transfer
Power Supply Unit
Error in the Primary Transfer High Voltage PCB,
Error in C primary transfer
Error in the Primary Transfer Roller (ITB Unit) 1.
abnormal detection
E067- Check failure of the harness between the Primary
When trying to apply the
0002 Transfer High Voltage PCB (UN04/J1001) and the
specified voltage of 1500 [V]
DC Controller PCB (UN09/J205) (open circuit,
or higher
trapped cable, connector disconnection). ->
34

Replace the harness if it is faulty 2. Check


connection failure between the Primary Transfer
High Voltage PCB (UN04/J21) and the Primary
Transfer Roller (Check that the connection is free
from open circuit or GND contact) 3. Replace the
Primary Transfer High Voltage PCB (UN04) 4.
Replace the ITB Unit 5. Replace the DC Controller
PCB (UN09). 6. Replace the Primary Transfer
Power Supply Unit
Error in the Primary Transfer High Voltage PCB,
Error in the Primary Transfer Roller (ITB Unit)
1.Check failure of the harness between the
Primary Transfer High Voltage PCB (UN04/J1001)
and the DC Controller PCB (UN09/J205) (open
Error in Bk primary transfer circuit, trapped cable, connector disconnection). ->
abnormal detection Replace the harness if it is faulty 2. Check
E067-
When trying to apply the connection failure between the Primary Transfer
0003
specified voltage of 1500 [V] High Voltage PCB (UN04/J11) and the Primary
or higher Transfer Roller (Check that the connection is free
from open circuit or GND contact) 3. Replace the
Primary Transfer High Voltage PCB (UN04) 4.
Replace the ITB Unit 5. Replace the DC Controller
PCB (UN09) 6. Replace the Primary Transfer
Power Supply Unit
Error in the Secondary Transfer High Voltage
PCB, Error in the Secondary Transfer Roller 1.
Check failure of the harness between the
Secondary Transfer High Voltage PCB
(UN05/J201) and the DC Controller PCB
Abnormal current is (UN09/J10) (open circuit, trapped cable, connector
detected at the secondary disconnection). -> Replace the harness if it is faulty
E069- transfer 2.Check connection failure between the Secondary
0001 When 5 [uA] or smaller is Transfer High Voltage PCB (UN05/T1201) and the
detected at the secondary Secondary Transfer Outer Roller (Check that the
transfer connection is free from open circuit or GND
contact) 3. Replace the Secondary Transfer High
Voltage PCB (UN05) 4. Replace the Secondary
Transfer Outer Roller 5. Replace the ITB Unit 6.
Replace the DC Controller PCB (UN09) 7. Replace
the Secondary Transfer Power Supply Unit
Abnormal current is Error in the Secondary Transfer High Voltage
detected at the secondary PCB, Error in the Secondary Transfer Roller 1.
E069-
transfer Check failure of the harness between the
0002
When 100 [uA] or larger is Secondary Transfer High Voltage PCB
detected at the secondary (UN05/J201) and the DC Controller PCB
35

transfer (UN09/J10) (open circuit, trapped cable, connector


disconnection). -> Replace the harness if it is faulty
2. Check connection failure between the
Secondary Transfer High Voltage PCB
(UN05/T1201) and the Secondary Transfer Outer
Roller (Check that the connection is free from open
circuit or GND contact) -> Replace the connection
wire if it is faulty 3. Replace the Secondary
Transfer High Voltage PCB (UN05) 4. Replace the
Secondary Transfer Outer Roller 5. Replace the
ITB Unit 6. Replace the DC Controller PCB
(UN09).
Error in the Primary Transfer Disengagement
Solenoid, Error in the Primary Transfer
Disengagement Switch, or the ITB Guide Rail error
1. Replace the ITB Unit 2. Check the
Error in the primary transfer
harness/connector between the DC Controller
disengagement control
PCB (UN09/J11) and the Primary Transfer
At the primary transfer
E074- Disengagement Switch (SW01) 3. Check the
disengagement control, the
0000 harness/connector between the DC Controller
sensor fails to detect
PCB (UN09/J11) and the Primary Transfer
although the specified time
Disengagement Solenoid (SL01) 4. Check
has passed.
conduction of FU6 on the DC Controller PCB
(UN09) 5. Replace the ITB Guide Rail 6. Replace
the Main Drive 7. Replace the Fixing Drive 8.
Replace the DC Controller PCB (UN09)
The HP mark is at undetectable state, ITB Top
Sensor error, or error in the coupling between the
ITB Unit and the ITB Drive 1. Check if the ITB is
driven. When the ITB is driven 2-1. Check soil of
the HP mark on the ITB Belt 3-1. Check if there is
a scar at the edge of the ITB 4-1. Use your hand to
check if the shutter of the Registration Patch
ITB rotation detection error
Sensor Unit can be open 5-1. Check for soil on the
The sensor fails to detect
window of the Patch Sensor (UN43/ UN44) 6-1.
E074- although it passes through
Check movement of the Registration Shutter
FFFF the mark on the ITB for the
Solenoid (SL02) COPIER > FUNCTION > PART-
specified time (ITB is
CHK > SL to move SL02 7-1. Check the
detected as not rotating)
harness/connector between the DC Controller
PCB (UN09/J12) and the Patch Sensor
(UN43/J4007, UN44/ J4006) 8-1.Replace the
Registration Patch Sensor Unit 9-1 Replace the
ITB Unit. 10-1. Replace the DCON When the ITB
is not driven 2-2. Remove and then install the ITB
Unit 3-2 Replace the ITB Unit. 4-2. Replace the
36

Main Drive

Code Description Remedy


Scanner Motor movement error or BD signal error
1.COPIER > FUNCTION > PART-CHK > MTR; and move
M01 When the Scanner Motor (M01) moves 2-1. Check
the flexible cable/connector between the DC Controller
BD error PCB (UN09) and the Laser Scanner Unit 3-1. Replace
E100-
BD fails to be ready in the Laser Scanner Unit 4-1. Replace the DC Controller
0001
5 sec PCB (UN09) When the Scanner Motor (M01) does not
move 2-2. Check the harness/connector between the DC
Controller PCB (UN09) and the Laser Scanner Unit 3-2.
Replace the Laser Scanner Unit 4-2. Replace the DC
Controller PCB (UN09)
BD error
E100- Unable to complete in
Polygon Motor error 1. Replace the Laser Scanner Unit
0002 5 sec since the facet
correction was started
Scanner Motor movement error or BD signal error
1.COPIER > FUNCTION > PART-CHK > MTR; and move
BD error M01 When the Scanner Motor (M01) moves 2-1. Check
During the drive at the flexible cable/connector between the DC Controller
the constant speed, PCB (UN09) and the Laser Scanner Unit 3-1. Replace
E100-
the BD cycle is the Laser Scanner Unit 4-1. Replace the DC Controller
0003
mismatched by -/+ PCB (UN09) When the Scanner Motor (M01) does not
0.5% for 500 move 2-2. Check the harness/connector between the DC
continuous msec Controller PCB (UN09) and the Laser Scanner Unit 3-2.
Replace the Laser Scanner Unit 4-2. Replace the DC
Controller PCB (UN09)
Scanner Motor movement error or motor control error
1.Check the harness/connector between the DC
Scanner Motor error
Controller PCB (UN09) and the Laser Scanner Unit
E110- Scanner Motor
2.Check the flexible cable/connector between the DC
0001 movement error or
Controller PCB (UN09) and the Laser Scanner Unit 3.
motor control error
Replace the Laser Scanner Unit 4. Replace the DC
Controller PCB (UN09)
Scanner Motor movement error or motor control error
Scanner Motor error 1.Check the harness/connector between the DC
E110- Scanner Motor Controller PCB (UN09) and the Laser Scanner Unit
0002 movement error or 2.Check the flexible cable/connector between the DC
motor control error Controller PCB (UN09) and the Laser Scanner Unit 3.
Replace the Laser Scanner Unit 4. Replace the DC
37

Controller PCB (UN09)


Scanner Motor error
E110- The signal fails to be Error in control with the Laser Scanner Unit 1. Replace
0003 1 at laser sequence the Laser Scanner Unit
enable check
The patch by the registration detection is not correctly
created, or registration patch sensor error 1. Clean the
dustproof glass. 2. Check density on the image visually.
When the image density is light 3-1. Clean the high
voltage contact point with dry wiping or air blower. 4-1.
Replace the Drum Unit (If the color showing abnormality
can be identified from the image, replace the Drum Unit
for that color. otherwise, replace from the Drum Unit (Y)
in order) 5-1.Check the harness/connector between the
DC Controller PCB (UN09) and the High Voltage PCB 6-
Registration detection
1.Replace the High Voltage PCB. Primary Charging High
error
Voltage PCB (UN06), Developing High Voltage PCB
E194- When the number of
(UN07), Auxiliary High Voltage PCB (UN08), Primary
0000 reading patterns fails
Transfer High Voltage PCB (UN04) 7-1 Replace the
to be the specified
DCON When the image density is not light 3-2. Use your
value
hand to check that the shutter of the Registration Patch
Sensor Unit can be open 4-2. Check for soil on the
window of the Patch Sensor (UN43, UN44) 5-2.Check
scar on the ITB. 6-2. Check movement of the
Registration Shutter Solenoid COPIER > FUNCTION >
PART-CHK > SL to move SL02 7-2.Check the
harness/connector between the DC Controller PCB
(UN09/J12) and the Patch Sensor (UN43/J4007, UN44/
J4006) 8-2. Replace the Registration Patch Sensor Unit
9-2 Replace the ITB Unit.
The last registration detection was not properly executed
1. Clear the registration detection data
COPIER>FUNCTION>CLEAR>REG-CLR 2. Clean the
window of the scanner 3. Check density on the image
visually. When the image density is light 4-1. Clean the
Registration detection high voltage contact point with dry wiping or air blower. 5-
error 1. Replace the Drum Unit (If the color showing
E194-
When there is an abnormality can be identified from the image, replace the
0001
image gap of Drum Unit for that color. otherwise, replace from the
3.25[mm] or larger. Drum Unit (Y) in order) 6-1. Check the harness/connector
between the DCON and the High Voltage PCB 7-
1.Replace the High Voltage PCB. Primary Charging High
Voltage PCB (UN06), Developing High Voltage PCB
(UN07), Auxiliary High Voltage PCB (UN08), Primary
Transfer High Voltage PCB (UN04) 8-1 Replace the
38

DCON When the image density is not light 4-2.Use your


hand to check that the shutter of the Registration Patch
Sensor Unit can be open 5-2. Check for soil on the
window of the Patch Sensor (UN43, UN44) 6-2.Check
scar on the ITB. 7-2. Check movement of the
Registration Shutter Solenoid COPIER > FUNCTION >
PART-CHK > SL to move SL02 8-2. Check the
harness/connector between the DC Controller PCB
(UN09) and the Patch Sensor (UN43/J4007,
UN44/J4006) 9-2. Replace the Registration Patch Sensor
Unit 10-2 Replace the ITB Unit.
Registration detection Connection failure between the DC Controller PCB
error (UN09) and the CB Controller PCB (UN11), error in the
There has been no DC Controller PCB (UN09), or error in the Controller PCB
E194-
command from CONT 1.Disconnect and then connect FFC (FFC 07) that is
FFFF
although 1 min has connected to the DC Controller PCB (UN09) and Main
passed since the start Controller PCB 2 (UN12) 2. Replace Main Controller PCB
of retry operation 2 (UN12) 3. Replace the DC Controller PCB (UN09)
E2PROM Error in access to EEPROM mounted on the Laser
E196- communication error Scanner. 1. Disconnect and then connect the connector
0001 I2C communication and Flat Cable of the Laser Scanner Unit. 2. Replace the
error Laser Scanner Unit.
EEPROM communication error in the DCON or the Drum
Unit 1. Check the harness/connector between the DC
E2PROM data
Controller PCB (UN09/J25) and the Drum Unit Relay
retrieval timeout
PCB (UN26/4011, UN27/J4014, UN28/J4017,
Within 10 sec since
E196- UN29/J4020) 2. Check the contact surface on the Drum
the power was turned
0002 Unit Relay PCB and the Drum Unit Memory PCB (soil,
ON, the E2PROM
damage, contact pressure) Y:UN26/UN30 M:UN27/UN31
data cannot be
C:UN28/UN32 Bk UN29/UN33 3. From Y Drum Unit,
developed to RAM
install each Drum Unit accordingly at a time to identify
error ROM 4. Replace the DC Controller PCB (UN09)
EEPROM communication error of the Drum Unit 1.Check
the harness/connector between the DC Controller PCB
E2PROM bus (UN09/J25) and the Drum Unit Relay PCB (UN26/4011,
possession error UN27/ J4014, UN28/J4017, UN29/J4020) 2.Check the
E196- The operation of the contact surface on the Drum Unit Relay PCB and the
0003 Drum Unit Memory Drum Unit Memory PCB (soil, damage, contact pressure)
PCB is faulty and Y:UN26/UN30 M:UN27/UN31 C:UN28/UN32 Bk
cannot be recovered UN29/UN33 3. From Y Drum Unit, install each Drum Unit
accordingly at a time to identify error ROM 4. Replace the
DC Controller PCB (UN09)
E196- E2PROM
Turn OFF and then ON the main power
1B00 communication error
39

Command error
E2PROM
E196-
communication error Turn OFF and then ON the main power
1B01
Command error
E2PROM
E196-
communication error Turn OFF and then ON the main power
1B02
Command error
40

Code Description Remedy


E2PROM communication
E196-
error Turn OFF and then ON the main power
1B03
Command error
E2PROM communication
E196-
error Turn OFF and then ON the main power
1B04
Command error
E2PROM communication
E196-
error Turn OFF and then ON the main power
1BFF
Command error
High Voltage contact point error or DC Controller
PCB error When this symptom occurs regularly 1-
1. Replace the DC Controller PCB (UN09) When
E197-
HOB communication error this symptom occurs incidentally 1-2. Check the
0000
high voltage contact point and clean the Primary
Transfer Roller Shaft Support 2-2. Replace the
DC Controller PCB (UN09)
High Voltage contact point error or DC Controller
PCB error When this symptom occurs regularly 1-
1. Replace the DC Controller PCB (UN09) When
E197-
HOB communication error this symptom occurs incidentally 1-2. Check the
0050
high voltage contact point and clean the Primary
Transfer Roller Shaft Support 2-2. Replace the
DC Controller PCB (UN09)
There is an error in the 1.Disconnect and then connect the flexible
detection of the Scanner cable(Relay PCB(PCB1)-Main Controller2
Unit home position. PCB(UN12)64Pin). 2.Replace the flexible cable.
E202-
The attempt to detect the 3.Replace the Scanner Unit HP sensor(SR1).
0001
home position fails when 4.Replace the Scanner Motor(M1). 5.Replace the
the Scanner Unit is Relay PCB(PCB1). 6.Replace the Main
moved forward. Controller2 PCB(UN12)
There is an error in the 1.Disconnect and then connect the flexible
detection of the Scanner cable(Relay PCB(PCB1)-Main Controller2
Unit home position. PCB(UN12)64Pin). 2.Replace the flexible cable.
E202-
The attempt to detect the 3.Replace the Scanner Unit HP sensor(SR1).
0002
home position fails when 4.Replace the Scanner Motor(M1). 5.Replace the
the Scanner Unit is Relay PCB(PCB1). 6.Replace the Main
moved back. Controller2 PCB(UN12)
The light intensity of the 1.Disconnect and then connect the flexible cable.
E225- Scanner Unit is faulty. 2.Replace the flexible cable. 3.Replace the
0001 The light intensity of the Scanner Unit. 4.Replace the Relay PCB(PCB1).
Scanner Unit during 5.Replace the Main Controller2 PCB(UN12).
41

shading is under the


specified level.
The reader unit power
1.Disconnect and then connect the power supply
E227- supply (24V) is faulty.
harness connector. 2.Replace the Power Supply
0001 At time of power-on, the
PCB(UN1).
24V port is off.
The reader unit power
1.Disconnect and then connect the power supply
E227- supply (24V) is faulty.
harness connector. 2.Replace the Power Supply
0002 At the start of a job, the
PCB(UN1).
24V port is off.
1.Disconnect and then connect the power supply
E227- At the end of a job, the
harness connector. 2.Replace the Power Supply
0003 24V port is off.
PCB(UN1).
The reader unit power
1.Disconnect and then connect the power supply
E227- supply (24V) is faulty.
harness connector. 2.Replace the Power Supply
0004 When a load is being
PCB(UN1).
driven, the 24V port is off.
Communication data error
1. Disconnect and then connect the FFC (FFC07)
Connection error between
that is connected to the DC Controller PCB
E240- the DC Controller PCB
(UN09) and Main Controller PCB 2 (UN12) 2.
0000 and Main Controller PCB
Replace Main Controller PCB 2 (UN12) 3.
2, or error in Main
Replace the DC Controller PCB (UN09)
Controller PCB 2.
1. Disconnect and then connect the FFC (FFC07)
Communication data error that is connected to the DC Controller PCB
E240-
60 sec while waiting for a (UN09) and Main Controller PCB 2 (UN12) 2.
0001
pickup request Replace Main Controller PCB 2 (UN12) 3.
Replace the DC Controller PCB (UN09)
1. Disconnect and then connect the FFC (FFC07)
Communication data error that is connected to the DC Controller PCB
E240-
60 sec while waiting for (UN09) and Main Controller PCB 2 (UN12) 2.
0002
an image output request Replace Main Controller PCB 2 (UN12) 3.
Replace the DC Controller PCB (UN09)

Code Description Remedy


1. Disconnect and then connect the FFC
(FFC07) that is connected to the DC
Communication data error
E240- Controller PCB (UN09) and Main Controller
After a paper jam, 60 sec has
0003 PCB 2 (UN12) 2. Replace Main Controller
passed without stopping
PCB 2 (UN12) 3. Replace the DC Controller
PCB (UN09)
42

1. Disconnect and then connect the FFC


Communication data error (FFC07) that is connected to the DC
E240- 60 sec has passed while waiting Controller PCB (UN09) and Main Controller
0004 for completion of the initial PCB 2 (UN12) 2. Replace Main Controller
rotation PCB 2 (UN12) 3. Replace the DC Controller
PCB (UN09)
1. Disconnect and then connect the FFC
Communication data error (FFC07) that is connected to the DC
E240- 60 sec has passed while waiting Controller PCB (UN09) and Main Controller
0005 for the start of auto adjustment at PCB 2 (UN12) 2. Replace Main Controller
warm-up rotation PCB 2 (UN12) 3. Replace the DC Controller
PCB (UN09)
1. Disconnect and then connect the FFC
(FFC07) that is connected to the DC
E240- Communication data error Controller PCB (UN09) and Main Controller
0006 Data access error PCB 2 (UN12) 2. Replace Main Controller
PCB 2 (UN12) 3. Replace the DC Controller
PCB (UN09)
1. Disconnect and then connect the FFC
(FFC07) that is connected to the DC
E240- Communication data error Controller PCB (UN09) and Main Controller
0007 Time notification error PCB 2 (UN12) 2. Replace Main Controller
PCB 2 (UN12) 3. Replace the DC Controller
PCB (UN09)
E246 System error Contact the service company office
E247 System error Contact the service company office
1.Disconnect and then connedt the flexible
cable(Relay PCB(PCB1)-Main Controller2
PCB(UN12)50pin). 2.Disconnect and then
connect the flexible cable(Scanner Unit- Relay
EEPROM error (Scanner Unit) PCB(PCB1)). 3.Disconnect and then connect
E248-
An error has occurred at power- the power supply harness connector.
0001
on. 4.Replace the flexible cable. 5.Replace the
Scanner Unit. 6.Replace the Relay
PCB(PCB1) 7.Replace the Power Supply
PCB(PCB1). 8.Replace the Main Controller2
PCB(UN12).
1.Disconnect and then connedt the flexible
cable(Relay PCB(PCB1)-Main Controller2
EEPROM error (Scanner Unit)
E248- PCB(UN12)50pin). 2.Disconnect and then
An error has occurred during
0002 connect the flexible cable(Scanner Unit- Relay
write operation.
PCB(PCB1)). 3.Disconnect and then connect
the power supply harness connector.
43

4.Replace the flexible cable. 5.Replace the


Scanner Unit. 6.Replace the Relay
PCB(PCB1) 7.Replace the Power Supply
PCB(PCB1). 8.Replace the Main Controller2
PCB(UN12).
1.Disconnect and then connedt the flexible
cable(Relay PCB(PCB1)-Main Controller2
PCB(UN12)50pin). 2.Disconnect and then
connect the flexible cable(Scanner Unit- Relay
EEPROM error (Scanner Unit)
PCB(PCB1)). 3.Disconnect and then connect
E248- An error has occurred during
the power supply harness connector.
0003 read operation following write
4.Replace the flexible cable. 5.Replace the
operation.
Scanner Unit. 6.Replace the Relay
PCB(PCB1) 7.Replace the Power Supply
PCB(PCB1). 8.Replace the Main Controller2
PCB(UN12).
Scanner Unit VSYNC signal
1. Turn OFF and then ON the power. 2. Check
error
the connection between Reader Relay PCB
Due to the VSYNC error in the
and Scanner Unit, and check that the Cable is
Scanner Unit which
E270- not open-circuit. 3. Check the connection
communicates with Reader
0001 between Reader and Printer, and check that
Relay PCB, VSYNC signal is not
the Cable is not open-circuit. 4. Replace the
sent appropriately, so the image
Reader Relay PCB. 5. Replace the Scanner
error occurs or the operation
Unit.
stops abnormally.
DDI HSYNC error 1. Turn OFF and then ON the power. 2. Check
Due to the DDI hardware the connection between Reader and Printer,
E270- HSYNC signal error, VSYNC and check that the Cable is not open-circuit.
0002 signal is not sent appropriately, 3. Replace the DDI-S Cable between Reader
so the image error occurs or the and Printer. 4. Replace the Reader Relay
operation stops abnormally. PCB.
1. Turn OFF and then ON the power. 2. Check
Communication error between
the connection between Reader Relay PCB
Reader Relay PCB and Scanner
and Scanner Unit, and check that the Cable is
Unit
E280- not open-circuit. 3. Check the connection
Within specified time,
0001 between Reader and Printer, and check that
communication between Reader
the Cable is not open-circuit. 4. Replace the
Relay PCB and Scanner Unit
Reader Relay PCB. 5. Replace the Scanner
cannot be made.
Unit.
Communication error between 1. Check the connection between Reader
Reader Relay PCB and Scanner Relay PCB and Scanner Unit, and check that
E280-
Unit the Cable is not open-circuit. 2. Check the
0002
Disconnection of the cable connection between Reader and Printer, and
between the Reader Relay PCB check that the Cable is not open-circuit.
44

and the Scanner Unit was


detected.
1.Disconnect and then connect the flexible
cable(Reader Relay PCB(PCB1)-Main
Readingunit communication
Controller PCB(UN12) 50pin). 2.Cisconnect
error
E280- and then connect the flexible cable(Scanner
Communication error at J507
0003 Unit- Reader Relay PCB(PCB1)). 3.Replace
and J508 conectors of the
the flexible cable. 4.Replace the Reader
Reader Relay PBC(PCB1).
Relay PCB(PCB1). 5.Replace the Main
Controller2 PCB(UN12).

Code Description Remedy


Readingunit communication 1.Disconnect and then connect the flexible
error cable(Reader Relay PCB(PCB1)-Main Controller
E280-
Communication error at PCB(UN12) 50pin). 2.Replace the flexible cable.
0004
J512 conector of the 3.Replace the Reader Relay PCB(PCB1).
Reader Relay PBC(PCB1). 4.Replace the Main Controller2 PCB(UN12).
1. Execute the service mode (COPIER >
FUNCTION > MISC-R > SCANLAMP) and check
that the LED of the Scanner Unit (Paper Front) is
Reading light intensity error
lit. 2. Check the connection between Scanner Unit
E301- The light intensity was at
(Paper Front) and LED, and check that the Cable
0001 the reference level or below
is not open-circuit. 3. Check the connection
at paper front shading.
between Reader Controller PCB and Scanner Unit
(Paper Front), and check that the Cable is not
open-circuit.
1. Check that the LED of the Scanner Unit (Paper
Back) is lit. 2. Check the connection between
Reading light intensity error
Scanner Unit (Paper Back) and LED, and check
E301- The light intensity was at
that the Cable is not open-circuit. 3. Check the
0002 the reference level or below
connection between Reader Controller PCB and
at paper back shading.
Scanner Unit (Paper Back), and check that the
Cable is not open-circuit.
1. Check that the LED of the Scanner Unit (Paper
Front) is lit. 2. Check the connection between
Error in paper front white
Scanner Unit (Paper Front) and LED, and check
shading
that the Cable is not open-circuit. 3. Check the
E302- Error in shading RAM
connection between Reader Controller PCB and
0001 access The shading value
Scanner Unit (Paper Front), and check that the
is out of the specified
Cable is not open-circuit. 4. Check the condition of
range.
Shading White Plate of the Stream Read Glass
(Paper Front) (scratches, dust, soil, etc.). 5. Check
45

if Scanner Unit (Paper Front) detects HP correctly.


(If it does not detect correctly, the Scanner Unit
reaches to the end when DF is opened.) 6.
Replace the Scanner Unit (Paper Front). 7.
Replace the Reader Controller PCB.
1. Check that the LED of the Scanner Unit (Paper
Front) is lit. 2. Check the connection between
Scanner Unit (Paper Front) and LED, and check
Error in paper front black
that the Cable is not open-circuit. 3. Check the
shading
condition of Shading White Plate of the Stream
E302- Error in shading RAM
Read Glass (Paper Front) (scratches, dust, soil,
0002 access The shading value
etc.). 4. Check if Scanner Unit (Paper Front)
is out of the specified
detects HP correctly. (If it does not detect correctly,
range.
the Scanner Unit reaches to the end when DF is
opened.) 5. Replace the Scanner Unit (Paper
Front). 6. Replace the Reader Controller PCB.
1. Turn OFF and then ON the main power 2.
E315- Image process device error
Check connection of Main Controller PCB 2 3.
0007 JBIG encode error
Replace Main Controller PCB 2
1. Delete the current job 2. Turn OFF and then ON
E315- Image process device error the main power 3. Check connection of Main
000d JBIG decode error Controller PCB 2 4. Replace the DDR-SDRAM, the
HDD and Main Controller PCB 2 at the same time
1. Delete the current job 2. Turn OFF and then ON
E315- Image process device error the main power 3. Check connection of Main
000e Error at software decoding Controller PCB 2 4. Replace the DDR-SDRAM, the
HDD and Main Controller PCB 2 at the same time
1. Turn OFF and then ON the main power 2.
E315- Image process device error
Check connection of Main Controller PCB 2 3.
000f Error at MemoryCopy
Replace Main Controller PCB 2
1. Turn OFF and then ON the main power 2.
E315- Image process device error
Check connection of Main Controller PCB 2 3.
0027 ROTU timeout error
Replace Main Controller PCB 2
1. Turn OFF and then ON the main power 2.
E315- Image process device error
Check connection of Main Controller PCB 2 3.
0035 MemFill timeout error
Replace Main Controller PCB 2
1. Turn OFF and then ON the main power 2.
E315- Image process device error
Check connection of Main Controller PCB 2 3.
0100 PRIO overrun
Replace Main Controller PCB 2
Device timeout 1. Turn OFF and then ON the main power. 2.
E315-
An image synchronous Check the connection of the Main Controller PCB 2
0500
signal from the Main (including the flat cable). 3. Replace the flat cable.
46

Controller PCB 2 to the 4. Replace the Main Controller PCB 2.


Reader is not received
within 30 seconds.
Device abnormal
1. Turn OFF and then ON the main power. 2.
completion
E315- Check the connection of the Main Controller PCB 2
An abnormal signal from
0501 (including the flat cable). 3. Replace the flat cable.
the Main Controller PCB 2
4. Replace the Main Controller PCB 2.
to the Reader is detected.
Device timeout
An image synchronous 1. Turn OFF and then ON the main power. 2.
E315- signal from the Main Check the connection of the Main Controller PCB 2
0510 Controller PCB 2 to the (including the flat cable). 3. Replace the flat cable.
Reader is not received 4. Replace the Main Controller PCB 2.
within 30 seconds.

Code Description Remedy


Device abnormal completion 1. Turn OFF and then ON the main power. 2.
E315- An abnormal signal from the Check the connection of the Main Controller PCB
0511 Main Controller PCB 2 to the 2 (including the flat cable). 3. Replace the flat
Reader is detected. cable. 4. Replace the Main Controller PCB 2.
Device timeout
An image synchronous 1. Turn OFF and then ON the main power. 2.
E315- signal from the Main Check the connection of the Main Controller PCB
0520 Controller PCB 2 to the 2 (including the flat cable). 3. Replace the flat
Reader is not received cable. 4. Replace the Main Controller PCB 2.
within 30 seconds.
Device abnormal completion 1. Turn OFF and then ON the main power. 2.
E315- An abnormal signal from the Check the connection of the Main Controller PCB
0521 Main Controller PCB 2 to the 2 (including the flat cable). 3. Replace the flat
Reader is detected. cable. 4. Replace the Main Controller PCB 2.
Device timeout
An image synchronous 1. Turn OFF and then ON the main power. 2.
E315- signal from the Main Check the connection of the Main Controller PCB
0530 Controller PCB 2 to the 2 (including the flat cable). 3. Replace the flat
Reader is not received cable. 4. Replace the Main Controller PCB 2.
within 30 seconds.
Device abnormal completion 1. Turn OFF and then ON the main power. 2.
E315- An abnormal signal from the Check the connection of the Main Controller PCB
0531 Main Controller PCB 2 to the 2 (including the flat cable). 3. Replace the flat
Reader is detected. cable. 4. Replace the Main Controller PCB 2.
E315- Device timeout 1. Turn OFF and then ON the main power. 2.
47

0540 An image synchronous Check the connection of the Main Controller PCB
signal from the Main 2 (including the flat cable). 3. Replace the flat
Controller PCB 2 to the cable. 4. Replace the Main Controller PCB 2.
Reader is not received
within 30 seconds.
Device abnormal completion 1. Turn OFF and then ON the main power. 2.
E315- An abnormal signal from the Check the connection of the Main Controller PCB
0541 Main Controller PCB 2 to the 2 (including the flat cable). 3. Replace the flat
Reader is detected. cable. 4. Replace the Main Controller PCB 2.
Device timeout
An image synchronous 1. Turn OFF and then ON the main power. 2.
E315- signal from the Main Check the connection of the Main Controller PCB
0550 Controller PCB 2 to the 2 (including the flat cable). 3. Replace the flat
Reader is not received cable. 4. Replace the Main Controller PCB 2.
within 30 seconds.
Device abnormal completion 1. Turn OFF and then ON the main power. 2.
E315- An abnormal signal from the Check the connection of the Main Controller PCB
0551 Main Controller PCB 2 to the 2 (including the flat cable). 3. Replace the flat
Reader is detected. cable. 4. Replace the Main Controller PCB 2.
E350 System error Contact the service company office
1. Turn OFF and then ON the main power 2.
E351- Main Controller PCB 2 Disconnect and then connect the connector of the
0000 communication error Main Controller PCB 2. 3. Replace the Main
Controller PCB 2.
E354 System error Contact the service company office
E355 System error Contact the service company office
1. Turn OFF and then ON the power. 2. Check the
Communication error connection between Reader Controller PCB and
between Reader Controller DF Driver PCB (Signal Cable and Power Supply
E400- PCB and DF Unit Cable), and check that the Cables are not open-
0001 Communication checksum circuit. 3. Replace the Cable between Reader
error between Reader Controller PCB and DF Driver PCB. 4. Replace
Controller PCB and DF Unit the Reader Controller PCB. 5. Replace the DF
Driver PCB.
1. Turn OFF and then ON the power. 2. Check the
connection between Reader Controller PCB and
DF Driver PCB (Signal Cable and Power Supply
Communication error
E400- Cable), and check that the Cables are not open-
between Reader Controller
0002 circuit. 3. Replace the Cable between Reader
PCB and DF Unit
Controller PCB and DF Driver PCB. 4. Replace
the Reader Controller PCB. 5. Replace the DF
Driver PCB.
48

Code Description Remedy


1. Turn OFF and then ON the power. 2.
Disconnection of the Flat Cable Check the connection between Reader
between the Reader Controller Controller PCB and DF Driver PCB (Signal
PCB and DF Driver PCB Cable and Power Supply Cable), and check
E400-
Connection of the Flat Cable that the Cables are not open-circuit. 3.
0003
between the Reader Controller Replace the cable between Reader Controller
PCB and DF Driver PCB could PCB and DF Driver PCB. 4. Replace the
not be detected. Reader Controller PCB. 5. Replace the DF
PCB.
1.Replace the Release Motor HP
E413- Release Motor error sensor(SR11). 2.Replace the Release
0001 Release motor HP sensor open. Motor(M2). 3.Replace the ADF Driver
PCB(PCB1).
1.Replace the Release Motor HP
E413- Release Motor error sensor(SR11). 2.Replace the Release
0002 Release motor HP sensor close. Motor(M2). 3.Replace the ADF Driver
PCB(PCB1).
Communication error 1. Replace the finisher controller PCB. 2.
E500-
The communication with the host Replace the host machine DC Controller
0000
machine is interrupted. PCB.
Communication error 1. The wiring between the finisher controller
E503- Communication between the PCB and saddle controller PCB is faulty. 2.
0002 Saddle Controller and the The finisher controller PCB is faulty. 3. The
Finisher Controller is suspended. saddle stitcher controller PCB is faulty.
EEPROM error
E505-
The checksum for the EEPROM Replace the finisher controller PCB.
0001
data has an error.
1. The rear end assist home position sensor
Rear end assist home position
(PI109) is faulty. 2. The wiring between the
error
finisher controller PCB and rear end assist
E514- The stapler does not leave the
motor is faulty. 3. The end assist mechanism
8001 rear end assist home position
is faulty. 4. The rear end assist motor (M109)
when the rear end assist motor
is faulty. 5. The finisher controller PCB is
has been driven for 3 seconds.
faulty.
Rear end assist home position 1. The rear end assist home position sensor
error (PI109) is faulty. 2. The wiring between the
E514-
The stapler does not return to finisher controller PCB and rear end assist
8002
the rear end assist home position motor is faulty. 3. The end assist mechanism
when the rear end assist motor is faulty. 4. The rear end assist motor (M109)
49

has been driven for 3 seconds. is faulty. 5. The finisher controller PCB is
faulty.
Decurler HP detection error (at
intrusion amount control) 1. Check that the cam of the Decurler Roller is
E517- The HP was not detected within installed properly. 2. Replace the Decurler
0001 the specified period of time (2 Motor. 3. Replace the Buffer Driver PCB. 4.
seconds) since the start of the Replace the DC Controller PCB.
decurler HP detection.
1. The gear change home position sensor
Gear change home position error (PI117) is faulty. 2. The wiring between the
The gear change home position finisher controller PCB and gear change
E519-
sensor does not turn ON when motor is faulty. 3. The gear change
0002
the gear change motor has been mechanism is faulty. 4. The gear change
driven for 387 pulses. motor (M110) is faulty. 5. The finisher
controller PCB is faulty.
1. The gear change home position sensor
Gear change home position error (PI117) is faulty. 2. The wiring between the
The gear change home position finisher controller PCB and gear change
E519-
sensor does not turn OFF when motor is faulty. 3. The gear change
8001
the gear change motor has been mechanism is faulty. 4. The gear change
driven for 387 pulses. motor (M110) is faulty. 5. The finisher
controller PCB is faulty.
Shift Motor fails to move from HP
At initial rotation, when the Motor 1. Check if the Motor (M4) Connector is
rotates for specified period of physically removed. 2. Replace the Motor. 3.
E520-
time and cannot move from HP, Check if the Shift Roller HP Sensor (S2)
0001
it is detected as an error if the Connector is physically removed. 4. Replace
same symptom occurs again the Shift Roller HP Sensor (S2).
after the first retry
Shift Motor fails to return to HP
At initial rotation, when the Motor 1. Check if the Motor (M4) Connector is
rotates for specified period of physically removed. 2. Replace the Motor. 3.
E520-
time and cannot return to HP, it Check if the Shift Roller HP Sensor (S2)
0002
is detected as an error if the Connector is physically removed. 4. Replace
same symptom occurs again the Shift Roller HP Sensor (S2).
after the first retry.
Front aligning plate home 1. The front aligning plate home position
position error sensor (PI106) is faulty. 2. The wiring
The aligning plate does not leave between the finisher controller PCB and front
E530-
the aligningplate front home aligning plate motor is faulty. 3. The front
8001
position sensor when aligning plate is faulty. 4. The front aligning
thealignment plate front motor plate motor (M103) is faulty. 5. The finisher
has been driven for 4 seconds. controller PCB is faulty.
50

Front aligning plate home 1. The front aligning plate home position
position error sensor (PI106) is faulty. 2. The wiring
The aligning plate does not between the finisher controller PCB and front
E530-
return to aligning plate front aligning plate motor is faulty. 3. The front
8002
home position sensor when the aligning plate is faulty. 4. The front aligning
alignment plate front motor has plate motor (M103) is faulty. 5. The finisher
been driven for 4 seconds. controller PCB is faulty.

Code Description Remedy


Stapler Motor fails to move from HP 1. Check if the Motor (M10) Connector
At initial rotation, when the Motor is physically removed. 2. Replace the
E531- rotates for specified period of time and Motor. 3. Check if the Stapler HP
8001 cannot move from HP, it is detected as Sensor (S18) Connector is physically
an error if the same symptom occurs removed. 4. Replace the Stapler HP
again after the first retry. Sensor (S18).
Stapler Motor fails to return to HP 1. Check if the Motor (M10) Connector
At initial rotation, when the Motor is physically removed. 2. Replace the
E531- rotates for specified period of time and Motor. 3. Check if the Stapler HP
8002 cannot return to HP, it is detected as Sensor (S18) Connector is physically
an error if the same symptom occurs removed. 4. Replace the Stapler HP
again after the first retry. Sensor (S18).
STP Move Motor fails to move from HP 1. Check if the Motor (M1) Connector is
At initial rotation, when the Motor physically removed. 2. Replace the
E532- rotates for specified period of time and Motor. 3. Check if the Stapler Move HP
0001 cannot move from HP, it is detected as Sensor (S10) Connector is physically
an error if the same symptom occurs removed. 4. Replace the Stapler Move
again after the first retry. HP Sensor (S10).
STP Move Motor fails to return to HP 1. Check if the Motor (M1) Connector is
At initial rotation, when the Motor physically removed. 2. Replace the
E532- rotates for specified period of time and Motor. 3. Check if the Stapler Move HP
0002 cannot return to HP, it is detected as Sensor (S10) Connector is physically
an error if the same symptom occurs removed. 4. Replace the Stapler Move
again after the first retry. HP Sensor (S10).
1. The stapler drive home position
Stapler shift home position error sensor (PI110) is faulty. 2. The wiring
The stapler does not leave the stapler between the finisher controller PCB and
E532-
shifthome position when the stapler stapler shift motor is faulty. 3. The
8001
shift motor hasbeen driven for 5 stapler shift base is faulty. 4. The
seconds. stapler shift motor (M105) is faulty. 5.
The finisher controller PCB is faulty.
E532- Stapler shift home position error 1. The stapler drive home position
8002 The stapler does not return to the sensor (PI110) is faulty. 2. The wiring
51

stapler shift home position when the between the finisher controller PCB and
stapler shift motor has been driven for stapler shift motor is faulty. 3. The
20 seconds. stapler shift base is faulty. 4. The
stapler shift motor (M105) is faulty. 5.
The finisher controller PCB is faulty.
1. The swing home position sensor
(PI105) is faulty. 2. The wiring between
Swing home position error
the finisher controller PCB and swing
E535- The stapler does not leave the swing
motor is faulty. 3. The swing
8001 home position when the swing motor
mechanism is faulty. 4. The swing
has been driven for 3 seconds.
motor (M106) is faulty. 5. The finisher
controller PCB is faulty.
1. The swing home position sensor
(PI105) is faulty. 2. The wiring between
Swing home position error
the finisher controller PCB and swing
E535- The stapler does not return to the
motor is faulty. 3. The swing
8002 swing home position when the swing
mechanism is faulty. 4. The swing
motor has bee driven for 3 seconds.
motor (M106) is faulty. 5. The finisher
controller PCB is faulty.
1. The aligning plate rear home position
sensor (PI107) is faulty. 2. The wiring
Rear aligning plate home position error
between the finisher controller PCB and
The aligning plate does not leave the
E537- aligning plate rear motor is faulty. 3.
aligning plate rear home position
8001 The rear aligning plate is faulty. 4. The
sensor when the alignment plate rear
rear aligning plate motor (M104) is
motor has been driven for 4 seconds.
faulty. 5. The finisher controller PCB is
faulty.
1. The aligning plate rear home position
sensor (PI107) is faulty. 2. The wiring
Rear aligning plate home position error
between the finisher controller PCB and
The aligning plate does not return to
E537- aligning plate rear motor is faulty. 3.
aligning plate rear home position
8002 The rear aligning plate is faulty. 4. The
sensor when the alignment plate rear
rear aligning plate motor (M104) is
motor has been driven for 4 seconds.
faulty. 5. The finisher controller PCB is
faulty.
Tray Lift Motor timeout error
1. Check if the Motor (M11) Connector
Unable to complete the operation even
is physically removed. 2. Replace the
after the specified period of time during
Motor failure occurs. 3. Check if the
E540- initial rotation. When the Motor remains
Stack Tray Clock Sensor (S14)
0001 in the same area for the specified
Connector is physically removed. 4.
period of time and the same symptom
Replace the Stack Tray Clock Sensor
occurs again after the first retry, it is
(S14).
detected as an error.
52

Tray Lift Motor clock errornds.


1. Check if the Motor (M11) Connector
At initial rotation, when the Tray Lift
is physically removed. 2. Replace the
Motor rotates and clock input is not
E540- Motor. 3. Check if the Stack Tray Clock
detected within the specified period of
0005 Sensor (S14) Connector is physically
time, it is detected as an error if the
removed. 4. Replace the Stack Tray
same symptom occurs again after the
Clock Sensor (S14).
first retry.
1. The tray 1 shift area sensor PCB is
Tray 1 time out error
faulty. 2. The wiring between the
If the tray does not return to home
finisher controller PCB and tray 1 shift
E540- position when the tray 1 shift motor is
motor is faulty. 3. The tray up/down
8001 driven for 25 seconds. If the tray does
mechanism is faulty. 4. The tray 1 shift
not move to other area when tray 1
motor (M107) is faulty. 5. The finisher
shift motor is driven for 5 seconds.
controller PCB is faulty.
1. The tray 1 shift area sensor PCB is
Tray 1 shift area error
faulty. 2. The wiring between the
The dangerous area is reached before
finisher controller PCB and tray 1 shift
E540- the tray 1 paper surface sensor detects
motor is faulty. 3. The tray up/down
8002 paper surface during the paper surface
mechanism is faulty. 4. The tray 1 shift
detection operation. A discontinuous
motor (M107) is faulty. 5. The finisher
area is detected during tray operation.
controller PCB is faulty.
1. The tray 1 shift area sensor PCB is
Swing guide switch/Staple safety faulty. 2. The wiring between the
switch error finisher controller PCB and tray 1 shift
E540-
The swing guide switch or staple safety motor is faulty. 3. The tray up/down
8003
switch is activated while the tray is mechanism is faulty. 4. The tray 1 shift
operating. motor (M107) is faulty. 5. The finisher
controller PCB is faulty.

Code Description Remedy


1. The tray 1 shift area sensor PCB
is faulty. 2. The wiring between the
The tray 1 shift motor clock error finisher controller PCB and tray 1
E540- The FG input cannot be detected when the shift motor is faulty. 3. The tray
8004 tray 1 shift motor has been driven for 0.2 up/down mechanism is faulty. 4.
second. The tray 1 shift motor (M107) is
faulty. 5. The finisher controller PCB
is faulty.
The tray 1 shift motor speed error 1. The tray 1 shift area sensor PCB
E540- The lock detection signal turns OFF 150 is faulty. 2. The wiring between the
8005 ms after the lock detection signal turned finisher controller PCB and tray 1
ON. shift motor is faulty. 3. The tray
53

up/down mechanism is faulty. 4.


The tray 1 shift motor (M107) is
faulty. 5. The finisher controller PCB
is faulty.
1. The tray 1 shift area sensor PCB
is faulty. 2. The wiring between the
The tray 1 shift motor acceleration error finisher controller PCB and tray 1
E540- The lock detection signal does not turn ON shift motor is faulty. 3. The tray
8006 when the tray 1 shift motor has been driven up/down mechanism is faulty. 4.
for 1 second. The tray 1 shift motor (M107) is
faulty. 5. The finisher controller PCB
is faulty.
1. The tray 1 shift area sensor PCB
is faulty. 2. The wiring between the
The tray 1 shift motor error finisher controller PCB and tray 1
E540- The lock detection signal does not turn shift motor is faulty. 3. The tray
8007 OFF when the tray 1 shift motor is at a up/down mechanism is faulty. 4.
stop. The tray 1 shift motor (M107) is
faulty. 5. The finisher controller PCB
is faulty.
Additional Tray Lift Motor timeout error
1. Check if the Motor (M12)
Unable to complete the operation even
Connector is physically removed. 2.
after the specified period of time during
Replace the Motor. 3. Check if the
E542- initial rotation. When the Motor remains in
Additional Tray Clock Sensor (S23)
0001 the same area for the specified period of
Connector is physically removed. 4.
time and the same symptom occurs again
Replace the Additional Tray Clock
after the first retry, it is detected as an
Sensor (S23).
error.
1. Check if the Motor (M12)
Additional Tray Lift Motor clock error
Connector is physically removed. 2.
At initial rotation, when the Tray Lift Motor
Replace the Motor. 3. Check if the
E542- rotates and clock signal is not detected
Additional Tray Clock Sensor (S23)
0005 within the specified period of time, it is
Connector is physically removed. 4.
detected as an error if the same symptom
Replace the Additional Tray Clock
occurs again after the first retry.
Sensor (S23).
1. The Tray 2 shift area sensor PCB
Tray 2 time out error is faulty. 2. The wiring between the
If the tray does not return to home position finisher controller PCB and tray 2
E542- when the tray 1 shift motor is driven for 25 shift motor is faulty. 3. The tray
8001 seconds. If the tray does not move to other up/down mechanism is faulty. 4.
area when tray 2 shift motor is driven for 5 The Tray 2 shift motor (M105) is
seconds. faulty. 5. The finisher controller PCB
is faulty.
54

Tray 2 shift area error


The upper limit area is reached before the 1. The tray 2 shift area sensor PCB
tray 2 paper surface sensor 1 detects the is faulty. 2. The wiring between the
paper surface during paper surface finisher controller PCB and tray 2
E542- detection operation. A discontinuous area shift motor is faulty. 3. The tray
8002 is detected during tray operation. During up/down mechanism is faulty. 4.
evacuation operation, arrival at the area The tray 2 shift motor (M105) is
beyond the tray 2 paper surface sensor 2 faulty. 5. The finisher controller PCB
is detected before this sensor detects is faulty.
paper surface.
1. The tray 2 shift area sensor PCB
is faulty. 2. The wiring between the
finisher controller PCB and tray 2
E542- shift motor is faulty. 3. The tray
Tray 2 shift area error
8003 up/down mechanism is faulty. 4.
The tray 2 shift motor (M105) is
faulty. 5. The finisher controller PCB
is faulty.
1. The Tray 2 shift area sensor PCB
is faulty. 2. The wiring between the
The tray 2 shift motor clock error finisher controller PCB and tray 2
E542- The FG input cannot be detected when the shift motor is faulty. 3. The tray
8004 tray 2 shift motor has been driven for 0.2 up/down mechanism is faulty. 4.
second. The Tray 2 shift motor (M105) is
faulty. 5. The finisher controller PCB
is faulty.
1. The tray 2 shift area sensor PCB
is faulty. 2. The wiring between the
The tray 2 shift motor speed error finisher controller PCB and tray 2
E542- The lock detection signal turns OFF 150 shift motor is faulty. 3. The tray
8005 ms after the lock detection signal turned up/down mechanism is faulty. 4.
ON. The tray 2 shift motor (M105) is
faulty. 5. The finisher controller PCB
is faulty.
1. The tray 2 shift area sensor PCB
is faulty. 2. The wiring between the
The tray 2 shift motor acceleration error finisher controller PCB and tray 2
E542- The lock detection signal does not turn ON shift motor is faulty. 3. The tray
8006 when the tray 2 shift motor has been driven up/down mechanism is faulty. 4.
for 1 second. The tray 2 shift motor (M105) is
faulty. 5. The finisher controller PCB
is faulty.
E542- The tray 2 shift motor error 1. The tray 2 shift area sensor PCB
8007 The lock detection signal does not turn is faulty. 2. The wiring between the
55

OFF when the tray 2 shift motor is at a finisher controller PCB and tray 2
stop. shift motor is faulty. 3. The tray
up/down mechanism is faulty. 4.
The tray 2 shift motor (M105) is
faulty. 5. The finisher controller PCB
is faulty.
Front Fan lock error
While the front fan is rotating, this machine
E551- stops the front fan after detecting the lock 1. Check the Fan (M8). 2. Replace
8001 signal. Then this machine retries to rotate the finisher controller PCB.
the front fan, but lock signal is detected
again, this machine displays the error.
Rear Fan lock error
While the rear fan is rotating, this machine
E551- stops the front fan after detecting the lock 1. Check the Fan (M9). 2. Replace
8002 signal. Then this machine retries to rotate the finisher controller PCB.
the rear fan, but lock signal is detected
again, this machine displays the error.

Code Description Remedy


Shift Roller Release Motor fails
to move from HP
1. Check if the Motor (M5) Connector is
At initial rotation, when the Motor
physically removed. 2. Replace the Motor. 3.
E567- rotates for specified period of
Check if the Shift Roller Release Sensor (S3)
0001 time and cannot move from HP,
Connector is physically removed. 4. Replace
it is detected as an error if the
the Shift Roller Release Sensor (S3).
same symptom occurs again
after the first retry
Shift Roller Release Motor fails
to return to HP
1. Check if the Motor (M5) Connector is
At initial rotation, when the Motor
physically removed. 2. Replace the Motor. 3.
E567- rotates for specified period of
Check if the Shift Roller Release Sensor (S3)
0002 time and cannot return to HP, it
Connector is physically removed. 4. Replace
is detected as an error if the
the Shift Roller Release Sensor (S3).
same symptom occurs again
after the first retry.
Entrance Roller Release/Stopper 1. Check if the Motor (M6) Connector is
HP Motor fails to return to HP physically removed. 2. Replace the Motor. 3.
At initial rotation, when the Motor Check if the Entrance Roller Release/Stopper
E56F-
rotates for specified period of HP Sensor (S5) Connector is physically
time and cannot return to HP, it removed. 4. Replace the Entrance Roller
is detected as an error if the Release/Stopper HP Sensor (S5).
56

same symptom occurs again


after the first retry.
Entrance Roller Release/Stopper
HP Motor fails to move from HP 1. Check if the Motor (M6) Connector is
At initial rotation, when the Motor physically removed. 2. Replace the Motor. 3.
E56F- rotates for specified period of Check if the Entrance Roller Release/Stopper
0001 time and cannot move from HP, HP Sensor (S5) Connector is physically
it is detected as an error if the removed. 4. Replace the Entrance Roller
same symptom occurs again Release/Stopper HP Sensor (S5
after the first retry.
Gripper Open/Close Motor fails
to move from HP
1. Check if the Motor (M7) Connector is
At initial rotation, when the Motor
physically removed. 2. Replace the Motor. 3.
E571- rotates for specified period of
Check if the Gripper Arm HP Sensor (S13)
0001 time and cannot move from HP,
Connector is physically removed. 4. Replace
it is detected as an error if the
the Gripper Unit HP Sensor (S13).
same symptom occurs again
after the first retry.
Gripper Open/Close Motor fails
to return to HP
1. Check if the Motor (M7) Connector is
At initial rotation, when the Motor
physically removed. 2. Replace the Motor. 3.
E571- rotates for specified period of
Check if the Gripper Arm HP Sensor (S13)
0002 time and cannot return to HP, it
Connector is physically removed. 4. Replace
is detected as an error if the
the Gripper Unit HP Sensor (S7).
same symptom occurs again
after the first retry.
Gripper Unit Move Motor fails to
move from HP
1. Check if the Motor (M2) Connector is
At initial rotation, when the Motor
physically removed. 2. Replaec the Motor. 3.
E575- rotates for specified period of
Check if the Gripper Unit HP Sensor (S7)
0001 time and cannot move from HP,
Connector is physically removed. 4. Replace
it is detected as an error if the
the Gripper Unit HP Sensor (S7).
same symptom occurs again
after the first retry.
Gripper Unit Move Motor fails to
return to HP
1. Check if the Motor (M2) Connector is
At initial rotation, when the Motor
physically removed. 2. Replace the Motor. 3.
E575- rotates for specified period of
Check if the Gripper Unit HP Sensor (S7)
0002 time and cannot return to HP, it
Connector is physically removed. 4. Replace
is detected as an error if the
the Gripper Unit HP Sensor (S7).
same symptom occurs again
after the first retry.
E584- Shutter home position error 1. The shutter home position sensor (PI113)
57

0002 The stapler does not return to is faulty. 2. The shutter mechanism is faulty.
the shutter home position when 3. The stack ejection motor (M102), shutter
the stack ejection motor has clutch (CL101), ang stack ejection lower roller
been driven for 3 seconds. clutch (CL102) is faulty. 4. The finisher
controller PCB is faulty.
1. The shutter home position sensor (PI113)
is faulty. 2. The wiring between the finisher
Shutter home position error controller PCB and stack ejection motor, and
The stapler does not leave the between the finisher controller PCB and
E584-
shutter home position when the shutter clutch is faulty. 3. The shutter
8001
stack ejection motor has been mechanism is faulty. 4. The stack ejection
driven for 30 seconds. motor (M102), shutter clutch (CL101), ang
stack ejection lower roller clutch (CL102) is
faulty. 5. The finisher controller PCB is faulty.
Paper positioning plate home
position error 1. The paper positioning plate home position
The paper positioning plate sensor (PI7) is faulty. 2. The positioning plate
E5F0-
home positio sensor does not drive mechanism is faulty. 3. The paper
8001
turn ON when the paper positioning plate motor (M4) is faulty. 4. The
positioning plate motor has been saddle stitcher controller PCB is faulty.
driven for 1500 pulses.
1. The paper positioning plate home position
Paper positioning plate home sensor (PI7) is faulty. 2. Open circuit of the
position error Harness between Finisher Controller PCB
The paper positioning plate and Stack Delivery Motor & between Finisher
E5F0-
home position sensor does not Controller PCB and Shutter Open/Close
8002
turn OFF when the paper Clutch 3. The positioning plate drive
positioning plate motor has been mechanism is faulty. 4. The paper positioning
driven for 300 pulses. plate motor (M4) is faulty. 5. The saddle
stitcher controller PCB is faulty.
1. The paper folding motor clock sensor (PI4)
and paper folding home position sensor
Paper folding motor lock error
E5F1- (PI21) is faulty. 2. The paper folding roller
The feed speed of the paper fold
8001 drive mechanism is faulty. 3. The paper
roller reaches 5 mm/sec or less.
folding motor (M2) is faulty. 4. The saddle
stitcher controller PCB is faulty.
Paper positioning plate home
1. The paper folding motor clock sensor (PI4)
position error
and paper folding home position sensor
The status of Paper Fold Home
E5F1- (PI21) is faulty. 2. The paper folding roller
Position Sensor does not change
8002 drive mechanism is faulty. 3. The paper
although the Paper Fold Motor is
folding motor (M2) is faulty. 4. The saddle
driven for a specified period of
stitcher controller PCB is faulty.
time.
58

Guide home position error


1. The guide home position sensor (PI13) is
The guide home position sensor
E5F2- faulty. 2. The guide plate drive mechanism is
does not turn ON when the guide
8001 faulty. 3. The guide Motor (M3) is faulty. 4.
motor has been driven for 700
The saddle stitcher controller PCB is faulty.
pulses.

Code Description Remedy


Guide home position error
1. The guide home position sensor (PI13) is faulty.
The guide home position
E5F2- 2. The guide plate drive mechanism is faulty. 3.
sensor does not turn OFF
8002 The guide Motor (M3) is faulty. 4. The saddle
when the guide motor has
stitcher controller PCB is faulty.
been driven for 50 pulses.
Aligning plate home position
error
1. The aligning plate home position sensor (PI5) is
The aligning plate home
E5F3- faulty. 2. The aligning plate drive mechanism is
position sensor does not turn
8001 faulty. 3. The aligning motor (M5) is faulty. 4. The
ON when the aligning plate
saddle stitcher controller PCB is faulty.
motor has been driven for
500 pulses.
Aligning plate home position
error
1. The aligning plate home position sensor (PI5) is
The aligning plate home
E5F3- faulty. 2. The aligning plate drive mechanism is
position sensor does not turn
8002 faulty. 3. The aligning motor (M5) is faulty. 4. The
OFF when the aligning plate
saddle stitcher controller PCB is faulty.
motor has been driven for 50
pulses.
Stitcher (rear) home position
error
The stitching home position 1. The stitcher home position sensor (rear) (SW5)
E5F4-
sensor does not turn ON is faulty. 2. The stitcher (rear) is faulty. 3. The
8001
when the stitch motor (rear) saddle stitcher controller PCB is faulty.
has been driven backward
for 0.5 sec.
Stitcher (rear) home position
error
The stitching home position 1. The stitcher home position sensor (rear) (SW5)
E5F4-
sensor does not turn OFF is faulty. 2. The stitcher (rear) is faulty. 3. The
8002
when the stitch motor (rear) saddle stitcher controller PCB is faulty.
has been driven forward for
0.5 sec.
E5F5- Stitcher (front) home position 1. The stitcher home position sensor (front) (SW7)
8001 error is faulty. 2. The stitcher (front) is faulty. 3. The
59

The stitching home position saddle stitcher controller PCB is faulty.


sensor does not turn ON
when the stitch motor (front)
has been driven forward for
0.5 sec.
Stitcher (front) home position
error
The stitching home position 1. The stitcher home position sensor (front) (SW7)
E5F5-
sensor does not turn OFF is faulty. 2. The stitcher (front) is faulty. 3. The
8002
when the stitch motor (front) saddle stitcher controller PCB is faulty.
has been driven backward
for 0.5 sec.
Paper pushing plate home 1. The paper pushing plate home position sensor
position error (PI14), paper pushing plate top position sensor
The paper pushing plate (PI15), and paper pushing plate motor clock
E5F6-
home position sensor does sensor (PI1) is faulty. 2. The paper pushing plate
8001
not turn ON when the paper drive mechanism is faulty. 3. The paper pushing
pushing plate motor has plate motor (M8) is faulty. 4. The saddle stitcher
been driven for 0.5 sec. controller PCB is faulty.
Paper pushing plate home 1. The paper pushing plate home position sensor
position error (PI14), paper pushing plate top position sensor
The paper pushing plate (PI15), and paper pushing plate motor clock
E5F6-
home position sensor does sensor (PI1) is faulty. 2. The paper pushing plate
8002
not turn OFF when the paper drive mechanism is faulty. 3. The paper pushing
pushing plate motor has plate motor (M8) is faulty. 4. The saddle stitcher
been driven for 150 ms. controller PCB is faulty.
1. The paper pushing plate home position sensor
Paper pushing plate motor
(PI14), paper pushing plate top position sensor
clock error
(PI15), and paper pushing plate motor clock
E5F6- The number of pulses
sensor (PI1) is faulty. 2. The paper pushing plate
8003 detected by the paper
drive mechanism is faulty. 3. The paper pushing
pushing plate motor clock
plate motor (M8) is faulty. 4. The saddle stitcher
sensor is 6 pulses or less.
controller PCB is faulty.
1. The paper pushing plate home position sensor
Pushing position error
(PI14), paper pushing plate top position sensor
The paper pushing plate
(PI15), and paper pushing plate motor clock
E5F6- leading edge position sensor
sensor (PI1) is faulty. 2. The paper pushing plate
8004 does not turn ON when the
drive mechanism is faulty. 3. The paper pushing
paper pushing plate motor
plate motor (M8) is faulty. 4. The saddle stitcher
has been driven for 0.1 sec.
controller PCB is faulty.
Pushing position error 1. The paper pushing plate home position sensor
E5F6-
The paper pushing plate (PI14), paper pushing plate top position sensor
8005
leading edge position sensor (PI15), and paper pushing plate motor clock
60

does not turn OFF when the sensor (PI1) is faulty. 2. The paper pushing plate
paper pushing plate motor drive mechanism is faulty. 3. The paper pushing
has been driven for 0.5 sec. plate motor (M8) is faulty. 4. The saddle stitcher
controller PCB is faulty.
E602 HDD detection error
Image memory is faulty or
insufficient
E604-
0512MB memory needs to 1. Install a 0512MB or larger main memory
0512
be installed (insufficient
memory for the model)
Image memory is faulty or
insufficient
E604-
1024MB memory needs to 1. Install a 1024MB or larger main memory
1024
be installed (insufficient
memory for the model)

Code Description Remedy


Image memory is faulty or
insufficient
E604-
1536MB memory needs 1. Install a 1536MB or larger main memory
1536
to be installed (insufficient
memory for the model)
An error code to prevent
repeated resend due to
power shutdown during 1. Clear the FAX job information Execute the
E611-
FAX transmission following: COPIER > FUNCTION > CLEAR > FXTX-
0000
Repeated rebooting and CLR 2. Turn OFF and ON the main power.
resending in a short
period of time
Image memory is faulty or
insufficient
E613- Make a 512MB memory at Main Controller PCB 2
No necessary memory at
0512 side
Main Controller PCB 2
side
Image memory is faulty or
insufficient
E613- Make a 1024MB memory at Main Controller PCB 2
No necessary memory at
1024 side
Main Controller PCB 2
side
E613- Image memory is faulty or Make a 1536MB memory at Main Controller PCB 2
1536 insufficient side
61

No necessary memory at
Main Controller PCB 2
side
E614 Flash PCB detection error
Error in self-diagnosis of
the encryption module
E615- 1. Reinstall the system software. 2. Replace the
An error was found in
0001 HDD.
self-diagnosis of the
encryption library.
Note: Note: For the part described as the Main
FAX Board
Control PCB, it indicates Main Controller PCB 2
communication error
when the FAX Board is for 1 line, and Main Controller
E674- The specified number of
PCB 1 when the FAX Board is for 2 lines. 1. Check
0001 errors was detected with
wire connection between the FAX Board and the
FAX Board
Main Controller PCB 2. Replace the FAX Board 3.
communication
Replace the Main Controller PCB
Note: Note: For the part described as the Main
Control PCB, it indicates Main Controller PCB 2
FAX Board
when the FAX Board is for 1 line, and Main Controller
E674- communication error
PCB 1 when the FAX Board is for 2 lines. 1. Check
0004 Error in access of the
wire connection between the FAX Board and the
modem IC used by FAX
Main Controller PCB 2. Replace the FAX Board 3.
Replace the Main Controller PCB
Note: Note: For the part described as the Main
Control PCB, it indicates Main Controller PCB 2
FAX Board
when the FAX Board is for 1 line, and Main Controller
E674- communication error
PCB 1 when the FAX Board is for 2 lines. 1. Check
0008 Error in access of the port
wire connection between the FAX Board and the
IC used by OnBoardFax
Main Controller PCB 2. Replace the FAX Board 3.
Replace the Main Controller PCB
Note: Note: For the part described as the Main
FAX Board Control PCB, it indicates Main Controller PCB 2
communication error when the FAX Board is for 1 line, and Main Controller
E674-
An error was detected in PCB 1 when the FAX Board is for 2 lines. 1. Check
000C
access of the modem IC wire connection between the FAX Board and the
or port IC used by Fax Main Controller PCB 2. Replace the FAX Board 3.
Replace the Main Controller PCB
Note: For the part described as the Main Control
FAX Board
PCB, it indicates Main Controller PCB 2 when the
E674- communication error
FAX Board is for 1 line, and Main Controller PCB 1
0010 Error in timer device to be
when the FAX Board is for 2 lines. Replace the Main
used by FAX at activation
Controller PCB
62

FAX Board Note: For the part described as the Main Control
communication error PCB, it indicates Main Controller PCB 2 when the
E674-
Error when the timer FAX Board is for 1 line, and Main Controller PCB 1
0011
device to be used by FAX when the FAX Board is for 2 lines. Replace the Main
is started Controller PCB
FAX Board
When the power is turned ON, get in the download
E674- communication error
mode from service mode to execute downloading of
0030 Checksum error of USB-
USBFAX MAINROM
FAX MAINROM
Print server error
Error is detected by
E677- 1. Check cable connection and turn ON the power
checking of the mother
0003 again 2. Reinstall the printer server
board at startup of the
print server

Code Description Remedy


IPC initialization error
E710- Check the connection cable between the
Unable to be ready within 3 sec
0001 DC Controller PCB and the Finisher
after IPC chip was started
IPC register error
E711- Check the connection cable between the
4 or more errors are set to the error
0001 DC Controller PCB and the Finisher
register of the IPC chip in 1.5 sec
Finisher communication error 1
E713- Continuous interruption to RX
Turn OFF and then ON the main power
0001 communication from the Finisher
(Finisher down is detected)
Finisher communication error 2
E713-
A large amount of data from the Turn OFF and then ON the main power
0002
Finisher causes data overflow
Finisher communication error 3
E713- A large amount of data from the
Turn OFF and then ON the main power?a
0003 Finisher causes the reception buffer
overflow
E713- Finisher communication error 4
Turn OFF and then ON the main power
0004 OFF detection of detect signal
Finisher communication error 5
1. Check cable connection between the
E713- The DC Controller sent a command
Finisher and the host machine. 2. Turn
0005 to the Finisher three times, but no
OFF and then ON the main power.
response was received.
E713- Finisher communication error 6 Turn OFF and then ON the main power
63

0006 Error signal was received for 3


times in a row
Finisher communication error 7
E713- Overflow of driver buffer due to
Turn OFF and then ON the main power
0007 many requests from the upper task
before the process of the driver
Removing the Finisher
E713-
Removal of the Finisher from the Turn OFF and then ON the main power.
0008
host machine was detected.
Check cable connection between the
charging management equipment and the
Coin vendor error
host machine While the charging
Error when the coin vendor is
management equipment is connected for
started - The Coin Vendor, which
E719- operation, clear the error in the case of
must have been connected before
0001 switching to the operation without the
the power was turned OFF, is not
charging management equipment (To
connected when the power is turned
prevent a misuse by removing the charging
ON
management equipment, this error code is
displayed)
Check cable connection between the
Coin vendor error charging management equipment and the
IPC error at coin vendor operation - host machine While the charging
Open circuit of IPC, unable to management equipment is connected for
E719- recover the IPC communication - operation, clear the error in the case of
0002 When open circuit of the switching to the operation without the
pickup/delivery signal cable is charging management equipment (To
detected - Invalid connection is prevent a misuse by removing the charging
detected management equipment, this error code is
displayed)
Check cable connection between the
charging management equipment and the
host machine While the charging
Coin vendor erro management equipment is connected for
E719- r- Communication error with the operation, clear the error in the case of
0003 coin manager occurs during unit switching to the operation without the
price acquisition at startup. charging management equipment (To
prevent a misuse by removing the charging
management equipment, this error code is
displayed)
Coin vendor error
E719- The coin vendor was connected to a
1. Disconnect the coin vendor
0004 model that does not support the
coin vendor
64

Check cable connection between the


charging management equipment and the
Coin vendor error
host machine While the charging
Error when the NewCardReader is
management equipment is connected for
started - The NewCardReader,
E719- operation, clear the error in the case of
which must have been connected
0011 switching to the operation without the
before the power was turned OFF,
charging management equipment (To
is not connected when the power is
prevent a misuse by removing the charging
turned ON)
management equipment, this error code is
displayed)

Code Description Remedy


Check cable connection between the charging
management equipment and the host machine
Coin vendor error
While the charging management equipment is
IPC error at NewCardReader
E719- connected for operation, clear the error in the
operation Open circuit of
0012 case of switching to the operation without the
IPC, unable to recover the
charging management equipment (To prevent a
IPC communication
misuse by removing the charging management
equipment, this error code is displayed)
Serial communication error
when the NewCardReader is
1. Check if the cable of Serial NewCardReader is
started
E719- open circuit 2. Remove the Serial
Unable to start
0031 NewCardReader COPIER > Function > CLEAR >
communication with the
CARD COPIER > Function > CLEAR > ERR
Serial NewCardReader at
startup
Serial communication error
after the NewCardReader
was started
E719- Although communication with
Check if the NewCardReader cable is open circuit
0032 the Card Reader was
possible at startup, it became
unavailable in the middle of
communication
1. PDL reset processing (user mode > function
E730- PDL software error settings > printer > printer settings > utility >
1001 Initialization error Reset Printer) 2. Turn OFF and then ON the
power
1. PDL reset processing (user mode > function
E730- PDL software error
settings > printer > printer settings > utility >
100A Systematic fatal error occurs
Reset Printer) 2. Turn OFF and then ON the
65

power
1. PDL reset processing (user mode > function
PDL communication error
settings > printer > printer settings > utility >
No reply from PDL. No reply
E730- Reset Printer) 2. Turn OFF and then ON the
from PDL due to failure or
A006 power 3. Check connection of Main Controller
absence of the controller
PCB 2 4. Reinstall the controller firmware 5.
firmware
Replace Main Controller PCB 1
Mismatched PDL version
E730- Mismatch in version of the
System all format and installation
A007 control software between the
host machine and the PDL
1. Turn OFF and then ON the power 2. Reinstall
E730- PDL embedded font error
the system using SST or USB 3. System all
B013 Broken font data
format and reinstall the system using SST or USB
Initialization error
E730- An error, such as failure in System all format and installation Replace Main
C000 memory retrieval at startup, Controller PCB 1
occurs
1. Start in safe mode to format the HDD (all the
HDD access error
E730- data in the HDD is erased) 2. Replace the HDD 3.
An error occurs when
C001 Replace Main Controller PCB 2 4. Replace Main
accessing to the HDD
Controller PCB 1
Error in Main Controller PCB
1. Check connection of Main Controller PCB 2 2.
E731- 2
Replace Main Controller PCB 2 3. Replace Main
3000 Unable to recognize the Surf
Controller PCB 1
board
Error in Main Controller PCB 1. Check connection of Main Controller PCB 2 2.
E731-
2 Replace Main Controller PCB 2 3. Replace Main
3001
Failure in Surf initialization Controller PCB 1
Error in Main Controller PCB 1. Check connection of Main Controller PCB 2 2.
E731-
2 Replace Main Controller PCB 2 3. Replace Main
3002
Failure in Surf initialization Controller PCB 1
Error in Main Controller PCB
2 1. Check connection of Main Controller PCB 2 2.
E731-
Although it works normally at Replace Main Controller PCB 2 3. Replace Main
3015
the software side, there is no Controller PCB 1
video data into CL1-G
1. Check the connector connection with the
Scanner communication
E732- scanner 2. Check the power of the scanner > Is
error
0001 initialization executed at startup? 3. Replace the
DDI-S communication error
Reader Relay PCB, the Scanner PCB or Main
66

Controller PCB 2

Code Description Remedy


Scanner communication error
When a scanner is detected from
E732- the printer model for the first time (It
Turn OFF and then ON the power
9999 is recorded in the history, but “Turn
OFF and then ON the power again”
is displayed on the UI.)
Scanner communication error
E732- A network communication error in a 1.Checking network connection 2.Turn
FFFF development environment is OFF and then ON the main power.
detected.
1. Turn OFF and then ON the main power.
2. Check the connection of the Flexible
Cable between the DC Controller PCB
Printer communication error
(UN9) and the Main Controller PCB 2. 3.
A communication error between the
E733- Replace the Flexible Cable. 4. Check the
DC Controller PCB and the Main
0000 power of the DC Controller PCB (UN9).
Controller PCB 2 is detected at
(Check if the initialization operation is
startup.
executed at startup.) 5. Replace the DC
Controller PCB (UN9). 6. Replace the
Main Controller PCB 2.
1. Turn OFF and then ON the main power.
2. Check the connection of the Flexible
Cable between the DC Controller PCB
Printer communication error
(UN9) and the Main Controller PCB 2. 3.
A communication error between the
E733- Replace the Flexible Cable. 4. Check the
DC Controller PCB and the Main
0001 power of the DC Controller PCB (UN9).
Controller PCB 2 is detected at
(Check if the initialization operation is
startup.
executed at startup.) 5. Replace the DC
Controller PCB (UN9). 6. Replace the
Main Controller PCB 2.
1. Turn OFF and then ON the main power.
2. Check the connection of the Flexible
Printer communication error Cable between the DC Controller PCB
A communication error between the (UN9) and the Main Controller PCB 2. 3.
E733-
DC Controller PCB and the Main Replace the Flexible Cable. 4. Check the
0005
Controller PCB 2 is detected at power of the DC Controller PCB (UN9).
startup. (Check if the initialization operation is
executed at startup.) 5. Replace the DC
Controller PCB (UN9). 6. Replace the
67

Main Controller PCB 2.


1. Turn OFF and then ON the main power.
2. Check the connection of the Flexible
Cable between the DC Controller PCB
Printer communication error
(UN9) and the Main Controller PCB 2. 3.
A communication error between the
E733- Replace the Flexible Cable. 4. Check the
DC Controller PCB and the Main
0006 power of the DC Controller PCB (UN9).
Controller PCB 2 is detected at
(Check if the initialization operation is
startup.
executed at startup.) 5. Replace the DC
Controller PCB (UN9). 6. Replace the
Main Controller PCB 2.
Printer communication error
The Finisher connection information
differs between the Main Controller
E733- PCB 2 and the DC Controller PCB.
1. Turn OFF and then ON the power
9999 The information on the Main
Controller PCB 2 side is overwritten
by turning OFF and then ON the
power.
Printer communication error 1. Turn OFF and then ON the main power.
A communication error between the 2. Check the connection of the Flexible
E733-
DC Controller PCB and the Main Cable between the DC Controller PCB
F000
Controller PCB 2 is detected at (UN9) and the Main Controller PCB 2. 3.
startup. Replace the Flexible Cable
E740- Ethernet Board error
1. Replace the LAN card
0002 Invalid MAC address
E740- Ethernet Board error
1. Replace the LAN card
0003 Invalid MAC address
1. Turn OFF and then ON the power 2.
Check connection of the cable between
DDI communication error
the Reader and the Controller 3. Check
E743- SCI error, reception data NG,
voltage (+24V and +12V) on the Reader
0000 reception timeout, SEQ timeout
Relay PCB 4. Replace the DDI-S cable 5.
error
Replace the Reader Relay PCB 6.
Replace Main Controller PCB 2
E744 Language file error
1. Replace the Image Analysis Board (HW
board used for PCAM) 2. As a temporary
Engine ID error
E746- measure, remove the Image Analysis
Self-check error of Image Analysis
0021 Board and get in service mode: COPIER >
Board (HW board used for PCAM)
OPTION > LCNS-TR > ST-JBLK (Lv2); set
STJBLK from 1 to 0, and turn OFF and
68

then ON the power


1. Update the firmware of the Image
Analysis Board 2. As a temporary
Engine ID error measure, remove the Image Analysis
E746-
Wrong version of Image Analysis Board and get in service mode: COPIER >
0022
Board OPTION > LCNS-TR > ST-JBLK (Lv2); set
STJBLK from 1 to 0, and turn OFF and
then ON the power
1. Check if the Image Analysis Board is
correctly installed 2. Turn OFF and then
ON the power 3. If the problem is not
Engine ID error fixed, replace the Option Board. 4. As a
E746-
No reply from the Image Analysis temporary measure, remove the Image
0023
Board Analysis Board and get in service mode:
COPIER > OPTION > LCNS-TR > ST-
JBLK (Lv2); set STJBLK from 1 to 0, and
turn OFF and then ON the power

Code Description Remedy


1. Turn OFF and then ON the power 2. If the problem is
not fixed, replace the Image Analysis Board. 3. As a
Engine ID error
E746- temporary measure, remove the Image Analysis Board
Operation error of the
0024 and get in service mode: (Lv2) COPIER > OPTION >
Image Analysis Board
LCNS-TR > ST-JBLK ; set STJBLK from 1 to 0, and
turn OFF and then ON the power
E746- 1. Turn OFF and then ON the power 2. Replace the
Engine ID error
0031 TPM PCB
Format the system Use SST or USB memory to format
the HDD, and then execute downloading of the system
E746- Engine ID error software. See Chapter 6 Upgrading for details. For
0032 TPM key mismatch reference, the method using USB memory is shown
below: 1. Prepare USB memory in which the system
software was registered
Recovery is available if backup of the TPM has been
executed 1. Connect the USB memory in which the
TPM key is saved 2. Management Settings > Data
Engine ID error Management > TPM Settings; click [Restore TPM key]
E746-
Mismatched data in the 3. Enter the password that was specified at the time of
0033
TPM backup work 4. Once the restore completion screen is
displayed, click [OK] and remove the USB memory, and
then turn OFF and ON the main power switch. When
backup of the TPM key is not executed System format
69

is necessary Use SST or USB memory to format the


HDD, and then download the system software
TPM auto recovery
error
E746- The symptom is recovered by turning OFF and then ON
An error occurs when
0034 the power
clearing the HDD while
the TPM setting is ON
TPM version error
E746- TPM which cannot be
Install the supported TPM.
0035 used in this machine
was installed.
1. Turn OFF and then ON the power (send the data to
PDL rendering error
E747- Inc because running the data which generated an error
Image processing IC
1201 code causes another error code) 2. Replace Main
error
Controller PCB 2
Flash PCB error
E748- Replace the Flash PCB and install the system using
Unable to find IPL
2010 SST or USB
(startup program)
Main Controller PCB 2 1. Clean the terminal of Main Controller PCB 2, and
access error remove and then install Main Controller PCB 2 2. Clean
E748-
Necessary H/W on the terminal of Main Controller PCB 1, and remove and
2021
Main Controller PCB 2 then install Main Controller PCB 1 3. Replace Main
is not detected Controller PCB 2
Main Controller PCB 2
access error
1. Clean the terminal of DDR2-SDRAM, and remove
E748- Unable to initialize
and then install the DDR2-SDRAM 2. Replace the
2023 memory DDR2-
DDR2-SDRAM
SDRAM at the Main
Controller PCB 2 side
Main Controller PCB 2
1. Clean the terminal of DDR2-SDRAM, and remove
access error
and then install the DDR2-SDRAM 2. Check power
E748- The CPU at the Main
state of Main Controller PCB 2 and check around the
2024 Controller PCB 2 side
connector 3. Replace Main Controller PCB 2 4.
failed to complete
Replace Main Controller PCB 1
initialization
E748-
System error Contact the service company office
9000
Rebooting instruction
due to change of
E749- The symptom is recovered by turning OFF and then ON
MEAP configuration
0002 the power
There is a change in
configuration that
70

requires turning OFF


and then ON the power
Booting instruction due
to change in mAccele
configuration
E749- The symptom is recovered by turning OFF and then ON
There is a change in
0003 the power
configuration that
requires turning OFF
and then ON the power
Booting instruction due
to change in hardware
configuration
E749- The symptom is recovered by turning OFF and then ON
There is a change in
0005 the power
configuration that
requires turning OFF
and then ON the power

Code Description Remedy


It is recovered by turning OFF and
Restart direction due to configuration
then ON the main power. CAUTION
change.
This machine provides power to some
The option such as the Finisher and
PCBs even when in the main power
ADF was installed or removed when all
OFF status. The power supply is not
of following conditions were met and the
completely OFF by just turning OFF
machine configuration is changed when
E749- the main power switch and therefore,
the main power switch is turned ON. -
0006 the machine is unable to detect a
Settings/Registration > Preferences >
configuration change. When
Timer/Energy Settings > Quick Startup
disconnecting and then connecting a
at Power-on > ON - The Main Power
connector, always disconnect the
Switch is turned OFF - The power plug
power plug. Refer to the Service
of the machine is connected to the
Manual > Chapter 2 > External and
output.
Controls > Quick Startup for details
This symptom occurs when updating
Mismatch between the DC Controller the software that does not match with
PCB and the Driver PCB the DC Controller PCB 1. Check the
E750-
Error in combination of the software of downloaded software and then
0013
the DC Controller PCB with the electrical execute downloading again 2.
circuit Replace the DC Controller PCB
(UN09)
Downloading error 1. Check the log to identify the location
E753-
Firmware update error This symptom of the download error Check if the
0001
occurs when trying to update the target option is installed When the
71

firmware of an option that is not installed target option is not installed: -> The
symptom is recovered by turning OFF
and then ON the power (because
there is nothing to update) When the
target option is installed: -> Check if
the target option is properly installed
and see if the software to download is
for the correct target option, and then
execute downloading again.
Power Supply Cooling Fan error 1. Check power supply to the Power
E804-
Lock of the Power Supply Cooling Fan is Supply Cooling Fan (FM1) 2.Replace
0000
detected the Power Supply Cooling Fan
The Fan is physically locked or failed,
or electrical trouble 1. COPIER >
FUNCTION > PART-CHK > FAN; and
then move FM04 When the 3 Way
Unit Cooling Fan (FM04) works 2-1.
Check the harness/connector between
the DC Controller PCB (UN09) and the
3 Way Unit Cooling Fan (FM04) 3-1.
Replace the 3 Way Unit Cooling Fan
(FM04) 4-1. Replace the DC Controller
PCB (UN09) When the 3 Way Unit
Error detection of 3 Way Unit Cooling Cooling Fan (FM04) does not work 2-
E806- Fan 2. Turn the 3 Way Unit Cooling Fan
0001 When lock of the 3 Way Unit Cooling (FM04) with your hand to check for
Fan was detected out for 15 sec rotation of the fan 3-2. Check the
harness/connector between the DC
Controller PCB (UN09) and the 3 Way
Unit Cooling Fan (FM04) 2. Check
conduction of FU11 in the DC
Controller PCB (UN09) When the fuse
is blown out 5-2-1. Replace the DC
Controller PCB (UN09) When the fuse
is not blown out 5-2-2. Replace the 3
Way Unit Cooling Fan (FM04) 6-2-2.
Replace the DC Controller PCB
(UN09)
The Fan is physically locked or failed,
or electrical trouble 1.COPIER >
Error detection of Drum Unit Cooling
FUNCTION > PART-CHK > FAN; and
E807- Fan
then move FM07 When the Drum Unit
0001 Lock of the Drum Unit Cooling Fan was
Cooling Fan (FM07) works 2-1. Check
detected out for 15 sec
the harness/connector between the
DC Controller PCB (UN09) and the
72

Drum Unit Cooling Fan (FM07) 3-1.


Replace the Drum Unit Cooling Fan
(FM07) 4-1. Replace the DC Controller
PCB (UN09) When the Drum Unit
Cooling Fan (FM07) does not work 2-
2. Turn the Drum Unit Cooling Fan
(FM07) with your hand to check for
rotation of the fan 3-2. Check the
harness/connector between the DC
Controller PCB (UN09) and the Drum
Unit Cooling Fan (FM07) 4-2. Check
conduction of FU9 in the DC Controller
PCB (UN09) When the fuse is blown
out 5-2-1. Replace the DC Controller
PCB (UN09) When the fuse is not
blown out 5-2-2. Replace the Drum
Unit Cooling Fan (FM07) 6-2-2.
Replace the DC Controller PCB
(UN09)
Electrical trouble with failed zero cross
signal 1. Check failure between the
AC Driver PCB (UN14/ J122) and the
DC Controller PCB (UN09/ J10).
(trapped cable, open circuit, connector
Zero cross signal detection error
disconnection) -> Replace the part in
E808- Unable to detect 43 to 57Hz for 5000
the case of trapped cable/open circuit
0001 msec or longer at the start of zero cross
2. Replace the AC Driver PCB (UN14)
detection
3. Replace the DC Controller PCB
(UN09) 4. Check the power supply
condition at the customer site. When it
is below 43 to 57Hz, ask for a
construction work.
Electrical trouble with failed zero cross
signal 1. Check failure between the
AC Driver PCB (UN14/ J122) and the
DC Controller PCB (UN09/ J10).
(trapped cable, open circuit, connector
Zero cross signal detection error
disconnection) -> Replace the part in
E808- Unable to detect 43 to 57Hz for 500
the case of trapped cable/open circuit
0002 msec or longer after confirmation of a
2. Replace the AC Driver PCB (UN14)
zero cross cycle
3. Replace the DC Controller PCB
(UN09) 4. Check the power supply
condition at the customer site. When it
is below 43 to 57Hz, ask for a
construction work.
73

Check if the connector is connected If


E880- Controller Fan error
the connector is OK, replace
0001 Lock of Controller Fan is detected
Controller Fan (FM3)
Depending on the setting of JM-ERR-
R in service mode, “010071” jam is
displayed as an error. Collect log and
E996-
Frequent error avoidance jam (ADF) contact to the sales companies. To
0071
cancel the setting, select COPIER>
OPTION> FNC-SW> J M-ERR-R, and
set JM-ERR-R to 0.
Make “000CA1” jam to be displayed
as an error by setting M-ERR-D in
service mode. Collect log and contact
E996- Frequent error avoidance jam
to the sales companies. To cancel the
0CA1 (PRINTER)
setting, select COPIER> OPTION>
FNC-SW> J M-ERR-D, and set JM-
ERR-D to 0.
Make “000CA2” jam to be displayed
as an error by setting M-ERR-D in
service mode. Collect log and contact
E996- Frequent error avoidance jam
to the sales companies. To cancel the
0CA2 (PRINTER)
setting, select COPIER> OPTION>
FNC-SW> J M-ERR-D, and set JM-
ERR-D to 0.
Make “000CA3” jam to be displayed
as an error by setting M-ERR-D in
service mode. Collect log and contact
E996- Frequent error avoidance jam
to the sales companies. To cancel the
0CA3 (PRINTER)
setting, select COPIER> OPTION>
FNC-SW> J M-ERR-D, and set JM-
ERR-D to 0.
Make “000CF1” jam to be displayed as
an error by setting M-ERR-D in service
mode. Collect log and contact to the
E996- Frequent error avoidance jam
sales companies. To cancel the
0CF1 (PRINTER)
setting, select COPIER> OPTION>
FNC-SW> J M-ERR-D, and set JM-
ERR-D to 0.

Você também pode gostar