Type NCX
– Enclosed cutout in porcelain housing – Used in replacement applications – 100 A fuse
– Designed for either dropout or in close spaces where there are – 200 A disconnect blade
non-dropout operation increased safety needs
– For indoor and outdoor use
– 7.8 kV, up to 12 kAIC
Type EU
Capacitor Fuses
Product Description Application
– Indoor, 600 V current limiting – Individual unit fusing of low voltage single and three-phase
– Rated current: 25 - 225 capacitors in metal enclosed equipment
Type CLN
– Indoor, 1.2 – 4.3 kV current limiting – Individual unit fusing of low voltage single and three-phase
– 1200, 1800, and 3000 V ratings are current limiting, capacitors in metal enclosed equipment
indicating, and non-disconnecting
– 2500 V and 4.3/2.5 kV ratings are current limiting,
non-indicating, and non-disconnecting
Type CLC
– Indoor, 2.8 - 23 kV current limiting and expulsion Two part design:
– Rated current: 6 - 65 - H igh current section interrupts high 60 Hz fault currents and/or
high frequency discharge current from parallel capacitors
- L ow voltage sections consist of a standard NEMA type K
Type CIL fuselink mounted in a fiber tube
– Outdoor application – Individual capacitor unit fusing in outdoor capacitor equipment
– 9.7 – 26.2 kV expulsion – Operates in all ungrounded wye applications and in all grounded
– Rated current: 6 - 100 wye applications when capacitor units are connected in two or
Type CXP more series groups
Type SID
– Loadbreak single insulator disconnect – Single-phase disconnect on overhead – Porcelain, polymer concrete, or
with self-contained loadbreak distribution feeders and in outdoor silicone rubber insulator
capabilities, a double blade door, and distribution substations (110 - 170 kV BIL)
two 2-hole NEMA pad terminals – Self-contained loadbreak enables – Mounting kit available
– 15.5 kV – 15/27 kV, 600 A continuous lineman to interrupt load current with a – 90° or 160° blade stop available
and loadbreak with a 40 kA momentary hookstick
rating – Can be mounted like a standard cutout
Type LSID
– Double insulator single-phase disconnect – Loadbreak tool-operated switch used – Porcelain or silicone rubber
switch for sectionalizing or isolating equipment insulator (110 - 150 kV BIL)
– 15 kV – 38 kV, 600 or 900 A continuous on electrical distribution systems up to – 90° or 160° blade stop available
loads with a 40 kA momentary rating 38 kV – Mounting kit available
– Can be mounted vertical or underhung,
or on a single or double crossarm
Type DCD
– Single-phase by-pass disconnect switch – Provides a means for bypassing and – Porcelain or silicone rubber
– 15 kV – 38 kV, 600 or 900 A continuous disconnecting reclosers or voltage insulator (110 - 150 kV BIL)
loads with a 40 kA momentary rating regulators, allowing maintenance on – 90° or 160° blade stop available
equipment without service interruption – Mounting kit available
– Can be mounted in the following
configurations: vertical or underhung,
pole-mounted, or single or double
crossarm
Type RBD
– Single-phase, non-loadbreak, inline – Used for manual switching of parallel – 90° or 160° stop blade available
tension disconnect switch with silicone or de-energized circuits on overhead
insulator distribution lines rated 15-38 kV
– Maximum voltage ratings: – Loadbreak hooks allow for operation
15 kV (150 kV BIL), 27 kV (150 kV BIL), with a portable loadbreak tool
or 38 kV (200 kV BIL)
– Continuous current rating of 600 A or
Type ITD 900 A
Electronic Sectionalizers