C01 MD-512-3000-EG-IN-4020-0004
REV DRAWING NUMBER CUSTOMER: HANWHA ENGINEERING & CONSTRUCTION SLEEVE MATERIAL: EPDM ENCAPSULATED RING
CUSTOMER P.O.: MD-512-3000-IN-MPO-4020-A01 RETAINER FLANGES: EPDM RUBBER LINED
PROJECT: MA'ADEN UMM WU'AL PHOSPHATE GATE MATERIAL: ALLOY 2205 DUPLEX STAINLESS STEEL GATE, RATED AT 1379 KPAG
KEYSTONE VALVE (KOREA) LLC P.O.: RE14002 MAWP (200 PSI)
A PENTAIR VALVES & CONTROLS RENO/FACTORY REFERENCE: S.O. 83228 DRAIN PLATES: BOTTOM DRAIN PLATE WITH FLUSH PORTS, CARBON STEEL A
SECONDARY SEAL: EPDM
KGVS CLA A+06MXXEE50009EF11HF00000000001 BODY/SEC SEAL RETAINER MATERIAL: DUCTILE IRON BODY (A536 GR 65-45-12), CS
MODEL: KGA06-MH-B9D13E10H12NR10Z (VALVE SIZE 150MM / 6" / AG13, AC16 (WPR)) SECONDARY SEAL RETAINER
BODY COATINGS/POST PROCESSING: EPOXY MASTIC PRIMER COAT + URETHANE
CLARKSON SERIES KGA+ HEAVY DUTY SLURRY KNIFE GATE VALVE MASTIC TOP COAT
MANUAL HANDWHEEL ACTUATED FLANGE DRILLING PATTERN: ANSI CLASS 150
FLAT-FACED BODY FLANGES WITH END CONNECTIONS TO MATCH ASME B16.5 / BOLTING MATERIAL: BODY & MOUNTING SCREWS A193-B7, NUTS A194-2H
CLASS 150 YOKE/FRAME MATERIAL: CARBON STEEL
DOUBLE SEATED BI-DIRECTIONAL DESIGN WITH HEAVY DUTY ELASTOMER SLEEVES, TAGGING: (1) STAINLESS STEEL TAG (PINNED ON), PER CUST SPEC
BUBBLE TIGHT SHUT OFF SPECIAL: HYDROSTATIC AND CERTIFIED FUNCTIONAL TESTING, PMI TESTING-GATE
IMPROVED SECONDARY SEAL WITH EXTERNAL LUBRICATION POINTS MATERIAL ONLY
PRODUCT CODE/SIZE: KGVS CLA KGA+ 06 INCH
ACTUATOR: MANUAL HANDWHEEL WITH STANDARD MANUAL OPERATOR TAG NUMBER: VAF-AQN15
STEM OPTION: 303 STEM
NOTES:
B B
C
DRAWN BY THIS DRAWING IS THE PROPERTY
JD 4/8/15
G
35 UNLESS OTHERWISE
DO NOT SCALE DRAWINGS.
OF PENTAIR VALVES & CONTROLS
UNAUTHORIZED USE IS PROHIBITED Proceed with exceptions to next submission and Revision G
146 SALES ORDER NO 83228
R
C PENTAIR VALVES & CONTROLS
2X 1/2 NPT DRAIN PORTS 148 1.37 SPECIFIED DIMENSIONS
5.75 ARE IN INCHES. Do Not Proceed - Revise as noted and Resubmit
5.81 FLANGE
PORT 324 TOLERANCES: FOR REFERENCE ONLY CERTIFIED PRE BUILT
12.76 PENTAIR DWG NO. Acceptance in any of these categories in no way relieves the Contractor/Supplier of
178±3 its responsibility for the due & proper performance of the Works in accordance with
G8 B REVISED TO CERTIFIED PRE BUILD 7/2/2015 JD 7.00±.13
DECIMAL: ANGULAR:
.X +/- 1.00 +/- 0.5
FOR APPROVAL CERTIFIED AS BUILT DC11348 the Contract/Purchase Order
PENTAIR REVISION:
AS SHIPPED
A5 A REV PER CUSTOMER COMMENTS 5/28/15 JD
.XX +/- .25
.XXX +/- .13 B PROJECT MANAGER SIGN-OFF:
ZONE REV. DESCRIPTION DATE DRAWN BY FRACTIONS=1/8
PENTAIR REVISIONS ENGINEERING PENTAIR VALVES & CONTROLS PAGE 1 OF 1 NAME DATE:
$FILEL$
Reno
permission of Ma'aden.
A1
SCALE
DOCUMENT NUMBER REFERENCE DOCUMENTS REV DATE REVISION DESCRIPTION DRN CHK ENG APP EMP MD-512-3000-EG-IN-4020-0004 C01
$DATE$
1 2 3 4 5 6 7 8 9 10 11 12