Micrologic Trip Unit

for Masterpact and Compact


Selection guide
Micrologic selection guide
 otors protection
M  otors from 25 to 220 A,
M  enerators from 40 to 630 A,
G
from 320 to 500 A Generators from 40 to 630 A, Distribution from 40 to 630 A
Distribution from 40 to 630 A
 tandard application
S Standard application Standard application with current measuremen
Type of application (green and office building, education, (green and office building, education,
hotel, food&beverage, etc. ) hotel, food&beverage, etc.)
(green and office building, education, hotel,
food&beverage, etc.)

Micrologic 1.3 M Micrologic 2.2 / 2.3 Micrologic 5.2A / 5.3A = (LSI) + Ammete
Micrologic 6.2A / 6.3A = (LSI + Ground
Ammeter
>> Motor Protection >> Basic protection (LSoI) >> Pre Alarm Ir
(I only) >> Pre Alarm Ir >> Led Ready
>> Communication Modbus, >> Led Ready >> Current measurement
Modbus TCP/IP >> Programmable contacts >> Programmable contacts
(Ir trip alarm) (Ir trip alarm, Ir pre alarm, Imax, Imin, und
>> Communication Modbus, current, contact wear, etc.)
Modbus TCP/IP >> Communication Modbus, Modbus TCP/IP

Type of tripping curve

Im

1.3-M Distribution
I and motors
0

t 2.2 Distribution
2.2 AB Service connection (public distribution)
Ir
2.2 G Generators
2.2 M Motors

Isd
0 I

2.3 Distribution
2.3 AB Service connection (public distribution)
2.3 M Motors

t
Ir 5.2 A Distribution and generators

Isd

Ii
0 I 5.3 A Distribution and generators

t
Ir 6.2 A Distribution and generators
t

Ig
Isd
tg
Ii
0 I 0 I 6.3 A Distribution and generators

t
Ir

I n
Isd
t
Ii
0 I 0 I

Breaker frame
Compact NSX 400/630 Compact NSX 100/630 Compact NSX 100/630
 otors from 25 to 220 A,
M  istribution from
D  istribution from
D D
Generators from 40 to 630 A, 630 to 3200 A 630 to 3200 A
Distribution from 40 to 630 A
nt Critical application with harmonics distortion and energy measurement Standard application without current Standard application with current Sta
(Data Center, healthcare, life science, MMM, Marine, water) measurement (green and office building, measurement (green and office building, (gr
education, hotel, food&beverage, etc.) education, hotel, food&beverage, etc.) foo

er Micrologic 5.2E / 5.3E = (LSI) + Energy meter Micrologic without Micrologic A Mi


fault) + Micrologic 6.2E / 6.3E = (LSI + Ground fault) + Energy meter measurement

>> Measurement (Voltage, frequency, power, maximeter, minimeter, >> Basic protection (LSIG), >> Basic protection (LSIG) >> B
energy, current and power demand, power quality) Pre Alarm Ir >> Residual Earth leakage >> T
>> Operating and maintenance assistance (alarms, trip history, setting >> Communication Modbus, protection (V) >> C
history, contact wear, alarm history, operation counter, load profile, Modbus TCP/IP >> Pre Alarm Ir >> P
der THD load profile, motor thermal image, etc.) >> Current measurement >> P
>> Advanced protection and functions (over voltage, reverse power, >> Communication Modbus, >> "
P load shedding, etc.) Modbus TCP/IP d
>> Programmable contacts (over consumption, rotation phase, >> P
max frequency, etc.) >> M
>> Communication Modbus, Modbus TCP/IP o
>> C

Micrologic 2.0 Micrologic 2.0 A Micr

2100A
_

100 % 100 %

40 % 40 %

menu menu

long time long time long time


Ir .8 tr 8
alarm Ir .8 tr 8
alarm Ir .8
.7 .9 (s) 4 12 .7 .9 (s) 4 12 .7 .9
.6 .95 2 16 .6 .95 2 16 .6 .95
.5 .98 1 20 .5 .98 1 20 .5 .98
.4 1 .5 24 .4 1 .5 24 .4 1
x In at 6 Ir x In at 6 Ir x In
instantaneous instantaneous instantaneous
Isd 4 5 Isd Isd
3 3 4 5 3 4 5
2.5 6 2.5 6 2.5 6
2 8 2 8 2 8
1.5 10 1.5 10 1.5 10
x Ir x Ir x Ir
setting setting setting

2.0 2.0 A 2.0

Micrologic 5.0 Micrologic 5.0 A Micr

2100A
_

5.2 E Distribution and generators


100 % 100 %

40 % 40 %

menu menu

long time long time long time


Ir .8 tr 8 alarm Ir .8 tr alarm Ir .8
.7 .9 (s) 4 12 .7 .9 (s) 4 8 12 .7 .9
.6 .95 2 16 .6 .95 2 16 .6 .95
.5 .98 1 20 .5 .98 1 20 .5 .98
.4 1 .5 24 .4 1 .5 24 .4 1
x In at 6 Ir x In at 6 Ir x In
short time instantaneous short time instantaneous short time
Isd tsd tsd Ii
.4 .4 .3
Ii Isd 4 Isd 4
3
4
5
(s) .4 .4 .3 6
8
10 3 5 (s) 6
8 10 3 5
2.5 6 .3 .2 4 12 2.5 6 .3 .2 4 12 2.5 6
2 8 .2 .1 3 15 2 8 .2 .1 3 15 2 8
.1 0 .1

5.3 E Distribution and generators


1.5 10 2 2 off 1.5 10 2 0 2 off 1.5 10
x Ir on I t x In on I t
x Ir x In x Ir
setting delay setting delay setting

5.0 5.0 A 5.0


Micrologic 6.0 Micrologic 6.0 A Micr

2100A
_

6.2 E Distribution and generators 6.2 E-M Motors


100 % 100 %

>30A >95 Micrologic 6.3 E-M


Ready

Alarm

% T° 40 % 40 %

380
350 400
320 440 Ir Cl. Isd Iunbal tunbal Ijam tjam Ig tg
280 470

500
250 500 menu menu
Ir (A) Ii=6500A
A IEC60947-4-1

.5 .6 .7 Class long time long time long time


.4 .8 Ir .8 tr 8
alarm Ir .8 tr 8
alarm Ir .8
N 1/A 2/B 3/C test .7 .9 (s) 4 12 .7 .9 (s) 4 12 .7 .9
.3 .9 .6 .95 2 16 .6 .95 2 16 .6 .95

.2 OFF Mode OK Ir 7.2Ir Isd


.5
.4 1
.98 1
.5
20
24
.5
.4 1
.98 1 20
24
.5
.4 1
.98
x In .5
Ig (x In) at 6 Ir x In at 6 Ir x In
short time instantaneous short time instantaneous short time
Isd tsd Ii Isd tsd Ii Isd
3
4 5 (s) . 4 .4 . 3 6
8 10
3
4 5 (s) .4 .4 .3 6
8 10 3
4 5
2.5 6 .3 .2 4 12 2.5 6 .3 .2 4 12 2.5 6
2 8 .2 .1 3 15 2 8 .2 .1 3 15 2 8
.1 2 0 off .1 2 0

6.3 E-M Motors


1.5 10 2 off

6.3 E Distribution and generators


on I t 1.5 10 2 1.5 10
x Ir x In on I t x In
x Ir x Ir
setting delay setting delay setting
test test
tg tg
Ig
D E F (s) . 4 .4 . 3 Ig
D E F (s) .4 .4 .3 Ig
D E F
C G .3 .2 C G .3 .2 C G
B H .2 .1 B H .2 .1 B H
A I .1 2 0 A I .1 2 0 A I
on I t off on I t off
ground fault ground fault ground fault

6.0 6.0 A 6.0


Micrologic 7.0 A

2100A

100 %

40 %

menu

long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir

short time instantaneous


Isd tsd Ii
3
4 5 (s) .4 .4 .3 6
8 10
2.5 6 .3 .2 4 12
2 8 .2 .1 3 15
1.5 10 .1 2 0 2 off
on I t off x In
x Ir
setting delay
test

IΔn 5 7 ΔI 230 350


3
2 10
140
1 20 800
.5 30 60
earth leakage

7.0 A

Compact NSX 100/630 Compact NS Compact NS


Distribution from 630 to 6300 A Distribution from 630 to 6300 A Distribution from 630 to 6300 A

andard application with energy measurement Critical application with energy measurement Critical application with harmonics distortion
reen and office building, education, hotel, (healthcare, green building, oil&gas, life science, and energy measurement (Data Center,
od&beverage, etc.) etc.) healthcare, life science, MMM, Marine, water)

icrologic E Micrologic P Micrologic H

Basic protection (LSIG), Micrologic E + Micrologic P +


Trip alarm, trip pre alarm >> Residual earth leakage protection (V) >> Power quality: Harmonic
Current, voltage, power factor measurement >> IDMTL long time protection individual up to 31st order, fundamentals,
Power and energy metering >> Protection and functions advanced (over THD, etc.)
Power and current demand voltage, reverse power, load shedding, etc.) >> Wave form capture after fault, alarm or
"Quickview" function for the automatic cyclical >> Programmable contacts (over consumption, on request
display of the most useful values rotation phase, max frequency, etc.) >> Enhanced alarm programming:
Programmable contacts (trip cause, pre alarm)
Maintenance information (load profile,
>> Maintenance information (wear contact,
alarm history, etc.)
thresholds and actions
>> Communication Modbus, Modbus TCP/IP
Earthing
operation counter, trip history) >> Communication Modbus, Modbus TCP/IP System
Communication Modbus, Modbus TCP/IP
Not
Applicable

rologic 2.0 E

TN-C
_5.678
MWh
TN-S
IT*

tr 8
alarm
(s) 4 12
2 16
1 20
.5 24
at 6 Ir

rologic 5.0 E Micrologic 5.0 P Micrologic 5.0 H

TN-C
_5.678
MWh
4260A 4200A
N 1 2 3
TN-S
N 1 2 3
100 100 IT*
50 50

0 0

long time
tr alarm Ir tr alarm
(s) 4 8 12 .8 (s) 4
8
.7 .9 12
2 16 .6 .95 2 16
1 20 .5 .98 1 20
.5 24 .4 1 .5 24
at 6 Ir x In @ 6 Ir

instantaneous short time instantaneous


tsd Ii
(s) .4 .4 .3 6
8 10 Isd
3
4
5
tsd
(s) .4 .4 .3
Ii
6 8 10
.3 .2 4 12 2.5 6 .3 .2 4 12
.2 .1 3 15 2 8 .2 .1 3 15
.1 2 0 2 off 1.5 10 .1 2 0 2 off
on I t x In x Ir on I t off x In
delay setting delay
test

E 5.0 P 5.0 H
rologic 6.0 E Micrologic 6.0 P Micrologic 5.0 H

TN-C
_5.678
MWh
4260A 4200A
N 1 2 3
TN-S
IT*
N 1 2 3
100 100

50 50

0 0

long time
tr 8
alarm Ir tr alarm
(s) 4 .8 8
12 .7 .9 (s) 4 12
2 16 .6 .95 2 16
1 20 .5 .98 1 20
.5 24 .4 1 .5 24
at 6 Ir x In @ 6 Ir

instantaneous short time instantaneous


tsd Ii Isd tsd Ii
(s) .4 .4 .3 6
8 10
3
4
5 (s) .4 .4 .3 6 8 10
.3 .2 4 12 2.5 6 .3 .2 4 12
.2 .1 3 15 2 8 .2 .1 3 15
.1 2 0 2 off 1.5 10 .1 2 0 2 off
on I t x In x Ir on I t off x In
delay setting delay
test test
tg Ig tg
(s) .4 .4 .3 D
E
F (s) .4 .4 .3
.3 .2 C G .3 .2
.2 .1 B H .2 .1
.1 2 0 A J .1 2 0
on I t off on I t off
ground fault

E 6.0 P 6.0 H
Micrologic 7.0 P Micrologic 5.0 H

TT
4260A 4200A
N 1 2 3 N 1 2 3

100 100

50 50

0 0

long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In @ 6 Ir

short time instantaneous


Isd tsd Ii
3
4
5 (s) .4 .4 .3 6 8 10
2.5 6 .3 .2 4 12
2 8 .2 .1 3 15
1.5 10 .1 2 0 2 off
x Ir on I t off x In
setting delay
test
I∆n ∆t
(A) 5 (ms)
3 7 230 350
2 10
1 20
140
.5 30 60 800

earth leakage

7.0 P 7.0 H

Compact NS Masterpact Compact NS Masterpact Masterpact

*IT = to add Vigilohm


Combine safety and performance
Masterpact and Compact Micrologic trip units provide outstanding
protection as well as an integrated measurement unit to help you monitor
power conditions and manage energy consumption.

Building & Infrastructure


Power management and monitoring
>> Optimize power consumption
>> Cost allocation
>> Integration in a Building Management System
through communication.

Industry
Power metering and control
>> Advanced protection
>> Alarming and programmable contact
>> Cost allocation
>> Diagnostic and maintenance
>> Continuity of service
>> Load trend monitoring
>> Integration in a supervision and control system
through communication (SCADA, DCS, etc.)
>> Management of energy quality.

IT
Critical Power
>> Power availability
>> Suitable for specific and advanced protection
>> Diagnostic and maintenance
>> Load trend monitoring
>> Integration in a supervision and control system
through communication
>> Management of energy quality.

Marine
High current protection
>> Specific motor protection
>> Total discrimination
>> Diagnostic and maintenance
>> Optimized size solution
>> Integration in a supervision and control system
through communication (SCADA, DCS, etc.)
>> Continuity of service.
Micrologic offer for Masterpact & Compact NS
Micrologic 2.0 Micrologic 5.0 A Micrologic 6.0 E Micrologic 7.0 P Micrologic 5.0 H

Micrologic 5.0 E
2100A MWh
4260A 4200A
_ _5.678
Type of measurement N 1 2 3
100
N 1 2 3
100

Version 100 % 100 % 50 50

Type of current protection


0 0
40 % 40 %

menu menu

long time long time long time long time


Ir .8 tr 8
alarm Ir .8 tr alarm Ir .8 tr 8
alarm Ir tr alarm
.7 .9 (s) 4 12 .7 .9 (s) 4 8 12 .7 .9 (s) 4 12 .8 (s) 4
8
.7 .9 12
.6 .95 2 16 .6 .95 2 16 .6 .95 2 16 .6 .95 2 16
.5 .98 1 20 .5 .98 1 20 .5 .98 1 20 .5 .98 1 20
.4 1 .5 24 .4 1 .5 24 .4 1 .5 24 .4 1 .5 24
x In at 6 Ir x In at 6 Ir x In at 6 Ir x In @ 6 Ir
instantaneous short time instantaneous short time instantaneous short time instantaneous
Isd tsd Ii Isd tsd Ii
3
4 5 Isd 4
3 5 (s) .4 .4 .3 6
8 10 3
4 5 (s) .4 .4 .3 6
8 10 Isd
3
4
5
tsd
(s) .4 .4 .3
Ii
6 8 10
2.5 6 2.5 6 .3 .2 4 12 2.5 6 .3 .2 4 12 2.5 6 .3 .2 4 12
2 8 2 8 .2 .1 3 15 2 8 .2 .1 3 15 2 8 .2 .1 3 15
1.5 10 1.5 10 .1 2 0 2 off 1.5 10 .1 2 0 2 off 1.5 10 .1 2 0 2 off
x Ir on I t on I t x In
x Ir x In x Ir x Ir on I t off x In
setting setting delay setting delay
test setting delay
test
tg I∆n ∆t
Ig
D E F (s) .4 .4 .3 (A)
3
5
7
(ms)
230
C G .3 .2 2 10
350
B H .2 .1 1 20
140
A I .1 2 0 .5 30 60 800
on I t off
ground fault earth leakage

without A E P H

2: Distribution L, I 2.0 2.0 2.0

5: Selective L, S, I 5.0 5.0 5.0 5.0 5.0

6: Selective and earth-fault protection L, S, I, G 6.0 6.0 6.0 6.0 6.0

7: Selective protection with earth-leakage protection L, S, I, V 7.0 7.0 7.0

Micrologic offer for Compact NSX


Micrologic 5.3 E
Type of measurement
Basic Frame Size
Type of current protection

M without A E

1: Motors I 1.3

2: Distribution L, I 2.2** – 2.3*

5: Selective L, S, I 5.2 – 5.3 5.2 – 5.3

6: Selective and earth-fault protection L, S, I, G 6.2 – 6.3 6.2* – 6.3*

* Motor protection available – ** Generator and motor protection available

A= Current measurement L= Long time protection


E= Energy measurement S= Short time protection
P= Power measurement I= Instantaneous protection
ART.056274 © 2012 Schneider Electric Industries - All rights reserved.

H= Harmonic measurement G= Ground fault protection


M= Motor protection V= Earth Leakage protection
Without = No measurement

Make the most of your energy™


www.schneider-electric.com

Schneider Electric Industries SAS


35, rue Joseph Monier As standards, specifications and designs change from time to time, please ask for confirmation
CS 30323 of the information given in this publication.
F- 92506 Rueil Malmaison Cedex
Printed on ecological paper
RCS Nanterre 954 503 439
Capital social 896 313 776 e Publishing: Schneider Electric Industries SAS
www.schneider-electric.com Design - Layout: SEDOC
Printing: Altavia Connexion
EDCED112019EN 07-2012