SET 3A

RADIOGRAPHIC INTERPRETATION – REPORT

Radiographic Identification: - A-B-C-D

Inspector: - _______________________________

Date: - ______________ Course: ________

Material: Carbon Steel Plate Thickness: 16 mm

Weld Thickness: 19 mm

Welding Process: MMA Edge Preparation: Single V

KV/ Source: Ir 192/ 1.5 X 1.5 mm Screens: Pb

Film Type: D7 (AGFA) FFD/SFD: 300 mm

Type of IQI used: _______________________ Technique:300 mm

Number of wire visible: ____________________________________________________

Film Density: a) Weld Zone _______________________________________


b) Parent Plate _______________________________________

________________________________________________________________________

Report
1. Calculate the sensitivity level for this radiograph?

2. Calculate the geometric unsharpness (Ug) based on the parameters given?

3. Comments on Radiographic Quality

a. Sensitivity: ________________ b. Density: ________________

c. Technique: __________________________________________________
RADIOGRPHIC REPORT (Set 3A)

1. SINGLE WALL SINGLE IMAGE (SWSI)

0 150

1 1

List of defects:
1. Lack of root penetration (+68mm from datum, 8mm long)
(+ 180mm from datum, 174 mm long)

2. Scattered porosity (+137 mm from datum, throughout the length)

150 300
3
2
5

1
List of defects:
3. External Undercut (+282 from datum, 8mm long) 3
(+325 from datum, 8mm long)

4. Cluster porosity (+271 from datum, 18mm long)

SET 3B
RADIOGRAPHIC INTERPRETATION – REPORT
Radiographic Identification: - TP 30

Inspector: - _______________________________

Date: - ______________ Course: ________

Material: Carbon Steel Plate Thickness: 12 mm

Weld Thickness: 15 mm

Welding Process: MMA Edge Preparation: Single V

KV/ Source: 140 KV Screens: Pb

Film Type: D7 (AGFA) FFD/SFD:

Type of IQI used: _______________________ Technique: SWSI

Number of wire visible: ____________________________________________________

Film Density: a) Weld Zone _______________________________________


b) Parent Plate _______________________________________

________________________________________________________________________

Report
1.Calculate the sensitivity level for this radiograph?

2. Calculate the geometric unsharpness (Ug) based on the parameters given?

Not Required

3.Comments on Radiographic Quality

a. Sensitivity: ________________ b. Density: ________________

c. Technique: __________________________________________________
RADIOGRPHIC REPORT
Set 3B
1. SINGLE WALL SINGLE IMAGE (SWSI)

0 150

1 2 1

List of defects:
1. Lack of Root Penetration (+72 from datum, 32mm long)
(+164 from datum, 10mm long)
(+263 from datum, 9 mm long)

2. Slag line (Wagon Track) (+ 105 from datum, 191mm long)

3. Slag inclusion (+300 mm from datum, 12 mm long)

150 300

2 1 3

4
List of defects:

4. Excessive weld (at the edge of weld, 4 mm long)