Ref. No.

: VAP/MF/095
Date : 27.5.2010

M/s Business Combines Ltd


16 MIDC Satpur
NASHIK 422 007.

Attn: Mr. Y.G. Thombare

Dear Sirs,

Sub: Your requirement of VAP Medium Frequency


Induction Furnace for melting Cast Iron
-----------

We refer to the visit our Mr. S.M. Joshi and the discussions he had with
you, we are enclosing our quote for VAP MK 7 1000 kgs/700 KW/300 Hz
Medium Frequency Induction Furnace for melting Iron.

This will provide you the good stirring (h/d) close to 0.21 which is almost
similar to the existing 350 KW/50 Hz 1000 kgs Mains Frequency Coreless
Crucible Induction Furnace.

Two systems will give you an output of 680 T/month, whereas your
requirement is 650 T only.

We shall thank you review our BUDGETARY and PREMILIMINARY


offer to examine that this will suit your requirement. In case if you require
further discussion, please call Mr. S.M. Joshi, who is located at Pune -
09420482941

He will be very happy to meet and have further discussion.

Thanking you,

Yours faithfully,
For VAP INDUCTION (INDIA) PVT LTD

D.G. SASTRY
MANAGING DIRECTOR

Encl: As above
QUOTE NO: VAP/QUO/112
DATE : 27.5.2010

TECHNICAL DATA

A. MEDIUM FREQUENCY POWER SUPPLY:

Type : VAP MK 7
Rated Power : 700 KW
Maximum Power : 770 KW
Nominal Frequency : 300 Hz
Input Voltage : 415 V, 3 ph., 50 Hz
Input Power Factor : Better than 0.93
Demand at Rated Power : 795 KVA
Demand at Max. Power : 875 KVA

B. FURNACE:

Type : Shuntless (Box)


Metal to be melted : Iron
Crucible Capacity : 1000 kgs
Pouring Temperature : 1500 Deg C
Type of lining : Silica
Output at RATED POWER with100%
Utilisation with lid : 1334 kgs/Hr
+/-5%
Energy Consumption : 552 KWH/T
+/-5%
Tilting : Hydraulic

C. COOLING WATER REQUIREMENT:

DM Water for Power Supply

Flow Rate : 160 lpm


Temperature rise : 10 Deg.C.

SOFT Water for Furnaces

Flow Rate : 360 lpm


Temperature rise : 15 Deg.C
PRICE SCHEDULE

1. VAP SCOPE PRICE SCHEDULE: (BUDGETARY)


1 No. 700 KW/300 Hz VAP Mk 7 V Power Supply
1 No. Leak Detector
2 Nos Furnace Selector Switches
2 Nos. 1000 kgs Shuntless (Box) Furnaces
2 Sets Busbar Runs 3 m. length
2 Sets Water Cooled leads
1 No. Hydraulic Power Pack

PRICE FOR THE ABOVE : Rs.52,75,000/-


(RUPEES FIFTY TWO LAKHS SEVENTY FIVE THOUSAND
ONLY)

2. OPTIONAL:

1 No. Remote Panel : Rs.55,000/-

1 No. Metering Panel : Rs.55,000/-

3. ERECTION AND COMMISSIONING:

We have considered Erection and Commissioning on supervisory basis.


Labour, tools and tackles will have to be provided by you. We will provide
you Engineers for this purpose.

LUMPSUM CHARGES FOR THE ABOVE: Rs.40,000/-


(RS FORTY THOUSAND ONLY)

In addition to the above, you will have to provide To and fro first class train
fare, free Board and Lodging in an appropriate Hotel as also local conveyance
for our Engineers during their stay at your site.
..2

:2:

4. AUXILIARIES:
To be arranged by you directly as per our ordering Specifications and
recommended suppliers. Estimated prices are given below:

WATER COOLING SYSTEM CONSISTING OF:

1 No. Plate type Heat Exchanger for DM Water


1 No. Plate type Heat Exchanger for Furnace Water
1 No. Cooling Tower
2 Nos DM Water Pumps
2 Nos Furnace Water Pumps
2 Nos Raw Water Pumps
1 No DM Plant CA 20 U
1 No Softening Plant S 200 U

ESTIMATED PRICE FOR THE ABOVE : Rs.6,75,000/-


(RS SIX LAKHS SEVENTY FIVE THOUSAND ONLY)

1 LOT PIPES AND FITTINGS TO BE ARRANGED BY YOU

for VAP INDUCTION (INDIA) PVT LTD

D.G. SASTRY
ANNEXURE I
DESCRIPTION OF VAP MK 7 POWER SUPPLY

VAP Mk – 7 is a highly advanced current fed system, having the highest


efficiency and excellent reliability. It has many salient features making it more
versatile and flexible than the traditional current fed system. It is completely self
contained and compact, having all the components housed in a sturdy cabinet, and
it consists of:

a. An Air circuit breaker, interlocked with the panel doors as a safety


measure

b. A controlled rectifier with thyristors of adequate rating and RC net


work, to provide electronic tripping.

c. A free wheeling diode

d. A DC filter choke (air cored)

e. Inverter modules consisting of fast acting special duty thyristors, RC


net works and saturable ferrite reactors.

f. Coupling capacitors to step up inverter voltage and will have tappings


for varying the tank voltage to meet different load conditions.

g. Capacitor contactors

h. Tank capacitors

i. Current sensor to measure power

j. Set of printed circuit boards for the control functions.

k. Control, feed back and phase reference transformers and are housed in
a separate dry compartment.

l. Set of indicating meters for coil voltage. DC voltage, power


frequency, ground leakage current and water conductivity.

m. Diagnostic board for fault memory and monitoring limits


..2

:2:

n. Water distribution system with pressure switches and thermostats

o. Set of push buttons and lamps and a knob for power selection.

All the above items are housed in a sturdy sheet metal cabinet provided with
doors and suitable for floor mounting.
ANNEXURE II

DESCRIPTION OF FURNACE CRUCIBLE

1. SHUNTLESS (BOX) FURNACE

SHUNTLESS (BOX) FURNACE is constructed of an aluminium frame. Its


inherent simplicity makes it suitable for a wide range of melting applications,
covering sizes from 25 kgs capacity to 2000 kg capacity in design frequencies of
200 Hz to 10000 Hz. Each Shuntless (Box) furnace will consists of the following.

FURNACE FRAME:

The furnace frame is made of aluminium section, given rigidity to the box and is
welded in a prescribed manner to avoid inductive loops which could cause
excessive heat and power loss. The sides of the Box is covered with removable
type fibre glass reinforced polyester sheets.

INDUCTION COIL:

The coil is made of high efficiency electrolytic copper sections. The coil turns are
spread and insulated with special type of insulating material. The gaps between
the turns are filled with spacers to give rigidity and the coil is head in position
solidly with studs. The coil terminals are taken out to accept water cooled power
leads. The induction coil is in two parts – one active section connected to
medium frequency power and a lower cooling coil to cool the bottom refractory.

CAST REFRACTORY BOTTOM:

The furnace bottom is cast refractory of high strength laminated construction and
have centered pedestal for locating the induction coil, providing maximum
thermal insulation and strength provided by stainless steel wire reinforcement.

CAST REFRACTORY TOP:

The furnace top is cast refractory block of high strength refractory material,
providing protection for the induction coil. This block also cast with stainless
steel wire reinforcement providing strength.

TILTING FRAME:
The tilting frame is support for the removable furnace Box and is made of rolled
steel sections to give rigidity. The hydraulic cylinder is connected to this frame
and this frame is tilted along with the Box frame.

..2

:2:

STATIONARY STRUCTURE:

The tilting frame is supported fabricated steel column type structure with dual
hydraulic cylinders. The cylinders are fitted with flow control valves for tilt and
descent control.

II. HYDRAULIC POWER PACK:

One Hydraulic power pack consisting of pump, motor, oil reservoir, pressure
relief valve, flow control valves, filter and pressure gauge.

III. BUSBARS FOR FURNACE CONNECTION:

One set of busbars for connecting the power supply to the flexible water-cooled
power leads of the furnace. Completely pre-fabricated and despatched in sections
convenient for transport.

The offer includes the price of the above busbars based on a distance of 3 m.
between the power supply and the furnace. The exact price will however depend
on the final layout.

IV. FURNACE SELECTOR SWITCHES (OPTIONAL)

Modular furnace switches mounted in the power supply cubicle permit selection
of alternative furnace listed in this offer. Features include

Safety interlocks
Front access for ease of servicing
Single throw cost aluminium handle
Stand off insulators

Both the fixed contacts and the moving contacts are water cooled. Hence are
capable of carrying high currents in a compact package.
The selector switches are provided with spring loaded contacts to ensure correct
contact pressures.

ANNEXURE -IIII

SPECIAL FEATURES OF PILLAR DESIGN VAP MK 7 POWER SUPPLY

1. CIRCUIT BREAKER:

Reliable standard circuit breaker used. No special circuit breaker required


because of the use of ‘Controlled Rectifier’. Current limiting reactors
resulting in additional losses are also not required,

2. CONTROLLED RECTIFIER:

Use of SCR’s (Thyristors) for the rectifier of simple diodes, provide


smooth output level control and circuit protection.

The rectifier electronically turns off in the event of short circuit or


disturbances in the power supply or load.

Back up protection using high speed semiconductor fuses are used to limit
currents to safe levels.

3. FILTER CHOKE:

Replaces the need for a large bank of filter capacitors (a common source
of problem on other designs). An exclusive designs for greater efficiency
and reliability.

4. INVERTER;

Least number of components per kw, means higher availability. Best


power factor and efficiency achieved at all power levels by keeping the
inverter frequency slightly above the natural resonant frequency of the
load.

Better stability because ‘Turn-off-time’ for the SCR becomes longer when fresh
charge is dropped into the crucible.

5. COUPLING CAPACITORS:

Lower and safe working voltages for the power semiconductor devices
and higher voltages for the furnaces, for higher efficiencies, are matched
by coupling capacitors. Inherently more efficient and readily replaceable
in the event of a failure, as compared to large special output transformers.
..2

:2:

6. PARALLEL CONNECTED OUTPUT:

More efficient than series connected outputs requiring special matching


transformers. The heavy series current passing through the matching
transformer results in high losses and lower efficiency.

7. WATER COOLING IN POWER SUPPLY:

All water tubes are of minimum 12 mm dia. Electrolytic erosion is


prevented by non-sacrificial targets. System is designed for 45oC water
inlet.

8. CONTROL ELECTRONICS:

Control boards hard wired for withstanding vibration and adverse service
environments. Circuits specially designed for high noise immunity.

LED’s in the diagnostic board display controlling mode and malfunctions.


Memory fault circuits help in diagnosing intermittent faults.

9. EARTH LEAKAGE DETECTION::

Ground current leakage detectors with furnace profile monitor provides


safe operation.

10. POWER FACTOR:

Power factor of furnace offered is 0.93 – 0.95 as long as furnace is not run
at low power levels. System incorporates facility for altering the ratio
between coil voltage and inverter output voltage. Hence, even at low
power levels say upto 40% it is possible to run the phase controlled
rectifier in full condition, thereby keeping a good input power factor.
11. We employ a constant current source parallel resonant system. Phase
controlled rectifier using thyristors instead of plain diodes used for
variable DC voltage for the inverter. Furnace power is varied by varying
DC voltage. This permits electronic tripping in case of any fault in the
furnace or inverter. At the first signs of any fault, the rectifier is totally,
phased back. Other manufacturers employing diodes for the rectifier have
to rely on moulded case circuit breaker to trip the power in case of such
faults. These mechanical breakers have much poorer life and replacement
costs are much heavy.

12. The inverter voltage and the furnace voltage are matched by a set of
coupling capacitors in Pillar design. Other manufacturers use water cooled
matching transformer where the losses can be as high on 4-5% (about 20
time the losses of the capacitors)
ANNEXURE IV

OTHER TERMS AND CONDITIONS

PRICE:
EX WORKS CHENNAI

EXCISE DUTY:
The rate applicable at the time of dispatch shall be to your account. Present rate of
Excise duty is 10% will be charged extra. Another 2% on Excise duty as CESS and S&H
EC @1% on ED will be charged

SALES TAX:
Sales-tax, Octroi and other levies will be charged extra to your account at the rate
prevailing at the time of dispatch.

SERVICE TAX:
Service Tax for Erection and Commissioning @10.3% shall be charged extra to your
account.

TRANSIT INSURANCE:

This is to be arranged by you. As soon as dispatches are made, we will send you the
particulars by cable to arrange for insurance.

PAYMENT:
30% of the value of the order as advance along with the order.
Balance against Proforma on readiness of the equipment, before dispatch.

DELIVERY:
Materials will be ready for dispatch from our works / sub-suppliers within 12 WEEKS
from the date of receipt of your technically and commercially clear order along with
advance and is subject to Force majeure clause.
MAKE:
Indigenous make
..2

:2:

PRICE VARIATION:
The above prices are subject to following price variation clauses.

a. IEMA price variation clause will be applicable to transformer, capacitors,


reactors, switch-gear items including circuit-breaker and laminations.

The base date for the application of IEMA Clause is 1st of this month. The break-
up of the prices for computing this shall be furnished to you at the time of
finalisation of order.

b. For products manufactured by us, Aluminium, Copper and Aluminium /


Copper cables etc. the rates published by HCL as on 1st of this month has been
considered. Any adjustment in these rates on date of supply with respect to the
date of our offer shall be to your account.

CHANGE IN THE EXCHANGE RATE AND CUSTOMS DUTY:


In the above quoted prices some of the components have been considered for import.
Therefore, any change in the exchange rate of Dollar to Rupee and the customs duty from
the date of Quotation to the date of despatch shall be to your account.

CANCELLATION CLAUSE:
The order once placed cannot be cancelled by you except with our written consent and
subject to cancellation charges which shall be as under

a. 10% order value if cancelled within 30 days from the date of placement
b. 20% order value if cancelled within 45 days from the date of placement
c. 50% order value if cancelled within 100 days from the date of placement.

VALIDITY:
Our offer is valid for 30 days from this date and thereafter subject to our confirmation of
price and delivery.

For VAP INDUCTION (INDIA) PVT LTD


ANNEXURE V

WARRANTY

We warranty the equipment covered by this Quotation against defects in workmanship


and materials under normal use and services, for a period of one (1) year. The one year
period commences on the start up or eighteen (18) months from the date of dispatch,
whichever event occurs first. We make no warranty (expressed or implied) of any other
kind with respect to the equipment.

OUR LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES TO PURCHASER
RESULTING FROM DEFECTIVE EQUIPMENT SHALL IN NO EVENT EXCEED
THE COST OF REPAIR OR REPLACEMENT FOR MADRAS OF DEFECTIVE
PARTS. IN NO EVENT SHALL WE BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL LOSSES

This warranty further excludes all parts subject to wear and tear, items such as indicating
bulbs, hydraulic seals, all fuses including semi conductor fuses, coils of contactors,
hydraulic hoses, refractory and lining materials.

For VAP INDUCTION (INDIA) PVT LTD


ANNEXURE VI

LIST OF EXCLUSIONS FROM OUR SCOPE OF SUPPLY

1. Civil Work

2. Illumination

3. Hydraulic Oil

4. Starters for water pumps and associated cabling

5. Ramming mass

6. L.T. Cable upto Distrtibution Board

7. H.T. cable upto breaker and transformer

8. L.T. Bus duct / LT cable up to Power Supply

9. Emergency cooling water system (Overhead tank, structure, pipeline and


fittings valve, diesel pump etc.)

10. Refractory material forming part of the civil work that is for the safety pit
in front of the furnace and below the furnace.

11. Hand rails, staircase, ladders, steps, grills, ducts, louvers, duct covers,
covers for erection openings, inserts in the civil works etc.

12. Cranes, hoists, monorails, charge and metal handling arrangements.

13. Pipes and Fittings


For VAP INDUCTION (INDIA) PVT LTD
ANNEXURE VII

QUALITY OF WATER

1. FURNACE WATER:
PH Value 7.2 TO 9

Total hardness as CaCO3 less than 100 ppm

Chloride content less than 20 ppm

Nitrate content less than 10 ppm

Sulphate content less than 100 ppm

Total dissolved solids content


Less than 250 ppm

Conductivity less than 400micromho per Cm

2. RAW WATER:
As available but with reasonably low hardness

DM WATER FOR POWER SUPPLY:


Conductivity less than 50 micromho per Cm.
ANNEXURE VIII

COOLING WATER SYSTEM FOR 700 KW SYSTEM

A PLATE TYPE HEAT EXCHANGER FOR POWER SUPPLY:


PHE to cool 160 lpm DM Water from 50 Deg.C. to 40 Deg.C. with the help of 200
lpm of Raw water getting heated to 40 Deg.C.from 32 Deg.C. The pressure drop at
primary side and secondary side should be within 6 mwc to 10 mwc respectively.

B PLATE TYPE HEAT EXCHANGER FOR FURNACE:


PHE to Cool 360 lpm of Furnace Water from 55 Degree C. to 40 Degree C. with
the help of 540 lpm, Raw water getting heated to 42 Deg. C from 32 Deg.C. The
pressure drop at primary side and secondary side should be within 6 mwc and 10
mwc respectively.

SUPPLIER: UNIWAY ENGINEERS P LTD


NEW NO. 29, 48th STREET
9TH AVENUE, ASHOK NAGAR
CHENNAI – 600 083
PHONE: 24714248, FAX : 24714989
E-mail: uniway@md3.vsnl.net.in

C COOLING TOWER:
Cooling tower to cool 740 lpm water from 42 Deg.C to 32 Deg. C The prevailing
wet bulb temperature at site may be considered.

SUPPLIER: Gem Cooling Towers P Ltd Paltech Cooling Towers &


B-2 Varshii Apartments Equipments Ltd
10/11 Eswaran Koil Street G-5 I Floor, G Block Market
West Mambalam Hauz Khas
CHENNAI – 600 033. NEW DELHI 110 016.
Phone: 23715625 / 790 Phone: 011- 26864351/52
Fax: 011- 26863737
E-mail: paltechcoolingtowers@vsnl.com

M/s Composite Aqua Systems & Equipments P Ltd


B-34, 3rd Stage
Peenya Industrial Area
BANGALORE – 560 058.
Phone: 080-51171788
Fax: 080 51171767
E-mail: case@compositeaqua.com
..2

:2:

D DM WATER PUMPS:
S.S./Bronze Pumps to deliver 160 lpm DM water at 3.5 kg/cm square pressure.

SUPPLIER: M/s Ajay Engineers


L-52 GIDC Odhav
AHMEDABAD – 382 415.
Phone: 079 2870333

E FURNACE WATER PUMPS:


Pump to circulate 360 lpm Soft water at 5 kg/cm square pressure

MAKE Beacon / Kirloskar

F RAW WATER PUMPS:


Pumps to circulate 740 lpm, at 3 kg/cm square pressure

MAKE: Beacon / Kirloskar

G DM PLANT AND SOFTENING PLANT:

We are enclosing water quality required for DM Plant and Softening Plant. Only
after knowing the quality of water we can recommend suitable DM Plant and
Softening Plant.

H PIPES AND FITTINGS:


1 Lot of Pipes and fittings as per our standard layout.