Você está na página 1de 2

Mission Critical Site Facilities Training

Certified
Data Centre
Specialist
Introduction
With few exceptions, enterprises today rely on IT for the
delivery of business-critical services - often directly to the
end consumer. It is therefore vital that the mission critical Would you like to join the elite group of
data center is designed, maintained and operated with hi- Certified Data Center Professionals?
availability and efficiency in mind. Fact is however that most
data center's do not meet the full availability, capacity, safety
World-Wide accredited by:
or efficiency requirements often demanded.
CDCSTM will further specialize attendees to a level where by
they will be a compatible sparring partner with suppliers and
will be able to verify offers provided by vendors for
correctness, effectiveness and efficiency. CDCSTM is a must
have certification for professional data centre managers and
Benefits realized
personnel. CDCSTM is a pre-requisite for persons wishing to
After completion of the course the you will be able to:
achieve the CDCETM status.
 Understand the design life cycle of data centers and
the stages involved
Certified Data Center Courses  Discuss in great level of detail requirements with
There are three levels of certification for Mission Critical Site vendors, suppliers and contractors and ensure that
Facilities courses: they do the right thing for the customers business
 CDCPTM: Certified Data Center Professional and not what is right for the vendor
 CDCSTM: Certified Data Center Specialist  Verify on the technical level design plans, quotes
 CDCETM: Certified Data Center Expert and offers proposed by vendors/contractors
 Understand Tier-levels for both the data center
For data center operations we have developed the course: design/setup as well as maintenance tier levels
 CDOMTM: Certified Data Center Operations Manager  Understand the various building considerations such
as bullet proofing, mitigation of seismic activity, fire
Audience ratings and thermal stability
The primary audience for this course is an IT, Facilities or  Understand how to build up a raised floor and
Data Center Operations professional working in and around making sure it is done properly to avoid
the data center and having responsibility to achieve and misalignment, level differences and leakage
improve hi-availability and manageability of the data center.  Understand how to read Single Line Electrical
Diagram and taking out the most common design
Prerequisites issues made.
Participants must hold a valid CDCPTM certificate in order to  Choose the right UPS and parallel configuration,
be able to register for the CDCSTM class. learn how to make sure that classic mistakes when
installing parallel systems can be avoided
 Understand how to calculate battery banks enabling
Delivery Structure you to double check offered configurations ensuring
This is an instructor-led course that uses a combination of they meet your requirements
presentation lectures and question and answer sessions to  Understand what distance to keep to avoid EMF
discuss attendees specific needs and issues experienced in issues for human safety and equipment disturbances
their own environment. Attendees are able to tap on the  Understand all about cooling setup and CFM, Delta-
trainer‟s extensive experience to solve practical problems in T and other important factors
their current environment adding tremendous value.  Understand contamination factors and limitations
 Understand full details of fire suppression options,
The Trainer how to calculate gas content and verify installations
This course will be delivered by a data center veteran with  Understand how to measure data center energy
many years of experience in designing and auditing of data efficiency and how to improve it
center's world wide.  And much, much more...
With many audits performed world-wide you can be assured
that the trainer has done it all and seen it all and provides
excellent practical experience and insights in what works and
what doesn't work when it comes to setting up, maintaining
Course Syllabus

Mission Critical Site Facilities Training


 Advanced Cooling
Day 1  Environmental class definitions and thermal specifications
 Data center design/life cycle overview
 Equipment airflow and Delta-T definitions and limits
 Overview of the phases of a data center life cycle
 Planning for floor, rack and cooling equipment
 Planning, re-alignment and continuous improvement
 CFM requirement calculations and conversions
 Tier levels
 Air-conditioner specifications and how to select the right air
 History of ‘tier level’ definitions
-conditioner with the right capacity and flow
 Tier level definitions, categories and measure points
 Techniques for optimization of air flow
 Redundancy options
 Redundancy guidelines for air-conditioners (no, it is not just
 Tiered Infrastructure Maintenance Standards (TIMS)
N+1….)
 Building considerations & standards
 Liquid cooling guidelines for data centers
 Floor loading requirements
 Advanced fire protection
 Fire rating for walls and glass
 Fire triangle and elements to stop a fire
 Blast protection
 Detection systems in detail (VESDA, VIEW, Smoke
 Bullet proofing
sensors)
 Forced entry protection
 Considerations for installation of sensors
 Advanced raised floor & suspended ceiling
 Difference in water based systems i.e. dry-pipe, pre-action
 Raised floor installation guidelines to ensure contractors
and why most of them don't work and how to detect this
install a proper closed and leveled raised access floor
 Details on Inert, Halocarbon, fluorinated systems and how
 Choosing the right tiles and their locations
to select the right gas for your data center
 Seismic mitigating floor constructions
 How to calculate the gas content ensuring the appropriate
 Choosing the right suspended ceiling
level is installed to suppress the fire
 Advanced Power
 Other requirements for gas systems (release times, hold
 Power infrastructure layout;
times, pipe install requirements and other important factors
 Formulas which you should know for the data center
 Requirements for the fire panel
 Single Line Electrical diagrams; how to read them and
 Installation verification, what to check and how
ensuring key components are present for protection
 New fire suppression techniques which prevents fires from
 Over current protection devices (MCB/MCCB/VCB/ACB/
even starting….. No more fire suppression gas cylinders...
Fuses) definitions and what to use where
 Cable management
 Earth Leakage devices (RCB/RCD/ELCB/GFCI/ALCI/
 Data center infrastructure cabling
RCBO), definitions and what to use where
 In rack power and network cabling
 Lightning strikes and surge protection devices (TVSS/
 Labeling based on TIA-606
SPD), how they work and where to use and how to
install
 Power cabling and cable run considerations Day 3
 PDU/DB setup and minimum requirements  Environmental specifications
 Generators;  Acoustic noise regulations, specifications, effects and limits
 component make up,  Data center contaminations and classifications
 choosing the right one,  Measurements, standards and limits
 calculate required fuel storage tank capacity,  Preventive measures and avoidance
 Paralleling of gen-sets  Electro Static Discharge (ESD)
 meeting regulatory requirements  Data center efficiency
 UPS systems;  Power efficiency indicators
 Required specifications for UPS systems  How to measure it and what are acceptable numbers
 How to read data sheets and select the right UPS compared to the general industry
 Requirements for parallel configurations and avoid  How to achieve power savings in the data center; various
pitfalls such as single point of failures techniques to save energy in all parts of the data center i.e.
 How parallel installation should be done, classic application/system level, cooling, power distribution
mistakes which installers make and how to avoid them
 Harmonic filters;  Question and Answers and exam preparation (if time
 Type of filters available and which one to select permits)
depending on the application
 Battery banks;  EXAM: Certified Data Center Professional
 Designing battery banks, how to calculate, and double
check, the battery bank to be installed
 Battery charging pitfalls and ensuring the right charger is Certification & Accreditation
being installed and used Certification exams will be administered at the end of the last
 Using parallel battery banks; how to properly install day of the course. The exam is a one and half hour, 60
them, limitations and risk when using batteries in parallel
questions, closed book exam. Results of the exam pass/fail
 How to test batteries correctly and make decisions on
cell/block or string replacement will be communicated to the attendee within four weeks after
 Battery casing choices; ABS, V0,V1,V2 the examination. Attendees who pass the exam will receive
 Alternative energy storage; flywheel, re-useable cell etc. the official “Certified Data Center Specialist” Certificate.
This world-wide recognized certificate is accredited by „The
Day 2 ICOR Group‟. ICOR operates world-wide and is a not-for-
 Advanced Electro Magnetic Fields profit education and credentialing organization that provides
 Differences between single, three phase and bus-bar EMF
 Options available to measure EMF and how to interpret the professional development, certification, thought-leadership,
results from single axe and composite measurements and the latest in research
 Guidance on safe distance for equipment and humans and industry trends in the
 Calculation of EMF attenuation factor for shielding area of organizational
 Material permeability and saturation factors
Asia/Pacific Headquarters:
Enterprise Product Integration Pte Ltd
37th Floor, Singapore Land Tower, 50 Raffles Place, Singapore 048623.
Tel: + (65) 6733-5900 Fax: + (65) 6735-6400,
e-mail: sales@epi-certification.com http:// www.epi-certification.com
Local offices in ; Malaysia, China, Vietnam, India, UK, France, Canada
Partner offices in ; China, Hong Kong SAR, Taiwan, Malaysia, Singapore, Indonesia, Philippines, Thailand, India, Pakistan,
Vietnam, Trinidad Tobago, Hungary, Ukraine, The Netherlands, Spain, United States of America, Canada

Você também pode gostar