Você está na página 1de 3

Audio Measurement Description http://wireless.agilent.com/rfcomms/refdocs/gsmgprs/meas_aaudio_top...

Home | Product Web Site | Contact Us

Search this guide for


8960 GSM/GPRS/EGPRS Online User's
search tips
Guide
E1968A, E6701F, E6704A

Contents
Call Processing
Measurements Analog Audio Measurement Description
Manual Operation
Programming Last updated: December 3, 2008
GPIB Commands
Protocol Logging This measurement is not applicable to GPRS or EGPRS.
Data Channel
Troubleshooting How is an analog audio measurement made?
Configuration
Fast Switching The analog audio measurement can measure Audio Level (V), SINAD (dB), Distortion
Release Notes
(%), and Audio Frequency. Measurements are made through the test set's front panel
Downloadable Manual
AUDIO IN connectors. When measuring a mobile's audio output, the audio signal may
come from either an acoustic coupler or from a test interface connection to the
mobile's audio circuitry.
Feedback
Did the information on SINAD is one of four measurements available from the Analog Audio measurement.
this web page help However, SINAD measurements are not typically made when testing GSM mobiles but
answer your question
or solve a problem? are more common when testing AMPS or analog mobiles.

Yes See Analog Audio Measurement Block Diagram .


No
The AUDIO IN connectors feed the inputs to a floating-input differential amplifier,
Did not apply
with each input having an impedance of about 100,000 ohms to chassis ground. For
Please provide best noise immunity, connect the audio signal and its ground reference to the two input
additional comments
about this page.
ports through shielded coaxial cables, or input the signal to the AUDIO IN HI
(Optional, 255 connector and ground the AUDIO IN LO connector's center contact.
character max)

SINAD/Distortion State

Select On or Off to enable or disable the SINAD and Distortion measurements. This
can be done remotely using the SETup:AAUDio:SDIStortion:STATe . When On, these
Email address
(optional): measurement results are displayed on the screen below the Audio Level measurement.
The SINAD/Distortion Fundamental Frequency must be entered to specify the audio
frequency for the measurement (range: 100 Hz to 10 kHz).
Privacy Notice: We
will not sell or give
Audio Frequency State
away your email
address to any third
party.
Select On or Off to enable or disable the analog audio frequency measurement.

Filter Type

None - no filtering is provided (default).


100 Hz BW BPF - The 100 Hz BW Band Pass Filter (Tunable) setting is
available when this filter is selected, and can be set in the range of 200 Hz to 20
kHz.
C-Message - This type of filter is typically used when testing AMPS or other

1 of 3 3/3/2010 9:33 AM
Audio Measurement Description http://wireless.agilent.com/rfcomms/refdocs/gsmgprs/meas_aaudio_top...

analog mobiles, and not GSM mobiles.


50 Hz to 15 kHz
300 Hz to 15 kHz

Detector Type

Select either Peak or RMS (default) for making and displaying an analog audio level
measurement (does not affect other measurements). The type of detector selected is
displayed next to the Audio Level measurement results. A 1-volt rms sinewave input
signal would measure 1.414 V Peak when the Peak detector is used. A 1-volt peak input
signal would measure 0.707 V RMS when the RMS detector is used.

Expected Peak Voltage

The Expected Peak Voltage sets the analog audio clipping level and must be set. This
voltage is always the absolute peak audio input signal voltage expected at the AUDIO
IN connectors, and must be in the range of 7.07 mV peak (5 mVrms) to 20 V peak .
Remember, measuring a 1-volt rms sinewave input signal would require a 1.414 V peak
expected voltage value to avoid clipping (over-driving) the input.

De-Emphasis State

Set to On or Off (default) to enable or disable 750 microsecond de-emphasis.

Expandor Reference Level

Set value from 10 mV/kHz to 10 V/kHz, or Off (default). Entering a numeric value
automatically turns the state to On. Entering Off disables the expandor (state = Off).

Trigger Source

Analog audio measurements use immediate triggering and are continuously re-triggered
each time the Trigger Arm parameter is set to Continuous. Trigger timing is
independent of any mobile protocol signaling.

Related Topics

Analog Audio Measurement Block Diagram

Analog Audio Troubleshooting

Audio Level Measurement Description

Audio Frequency Measurement Description

SINAD Measurement Description

Distortion Measurement Description

Programming an Audio Frequency Measurement

Programming an Audio Level Measurement

Programming a SINAD Measurement

Programming a Distortion Measurement

2 of 3 3/3/2010 9:33 AM
Audio Measurement Description http://wireless.agilent.com/rfcomms/refdocs/gsmgprs/meas_aaudio_top...

Statistical Measurement Results (Multi-measurements)

Triggering of Measurements

Measurement Timeouts

top of page

Privacy Statement | Terms of Use | Webmaster + © Agilent 2000-2008

3 of 3 3/3/2010 9:33 AM