Você está na página 1de 4

Weight of Roof:

Wr = Weight of Roof x T.A.R

Wr = 0.077 KN/m2 x 1.07m2

Wr = 0.082 KN

Weight of Purlins, (assume 75mm x 150mm)

Wp = (5.945 KN/m3) (0.075m) (0.15m) (2.0m)

Wp = 0.134 KN

Total Normal Load:

Wn = WL + (Wr + Wp) cosθ

Wn = 1.74 + (0.082 + 0.134) cos 26.5650

Wn = 1.93 KN

Total Tangential Load:

Wt = (Wr + Wp) sinθ

Wt = (0.082 + 0.134) sin 26.5650

Wt = 0.097 KN

Maximum Normal Shear:

Vn = (Wn/2)

Vn = 1.93/2

Vn = 0.97 KN

Maximum Tangential Shear:

Vt = (Wt/2)

Vt = 0.097/2

Vt = 0.049 KN
CHECK FOR BENDING:

Normal Moment
WnL
Mn =
8

1.93 (2.0)
Mn = 8

Mn = 0.483 KN-m

Tangential Moment
WtL
Mt = 8

0.097 (2.0)
Mt = 8

Mt = 0.024 KN-m

Normal flexure
6𝑀𝑛
ƒn =
𝑏𝑑 2
6 (0.483)(1000)2
ƒn = (75𝑥1502 )

ƒn = 1.72 MPa

Tangential flexure
6𝑀𝑡
ƒt =
𝑏𝑑 2
6 (0.024)(1000)2
ƒt = (150𝑥752 )

ƒt = 0.171 MPa

Total Bending, f:

FT = fn + ft

FT = 1.72 + 0.171

FT = 1.891 MPa < 19.30 MPa (SAFE IN FLEXURE)


CHECK FOR SHEAR:
3𝑉𝑛 3𝑉𝑡
Vn = Vt =
2𝑏𝑑 2𝑏𝑑
3(0.97)(1000) 3(0.049)(1000)
Vn = Vt =
2(75)(150) 2(75)(150)

Vn = 0.129 MPa Vt = 0.007 MPa

Total Shear:

V = √𝑉𝑛 2 + 𝑉𝑡 2

V = √0.1292 + 0.0072
V = 0.129 MPa < 1.96 MPa (SAFE IN SHEAR)

CHECK FOR DEFLECTION:

ϒallow = L/360 = 2000/360


ϒallow = 5.56 mm

5𝑊𝑛 𝐿3
ϒactual =
384𝐸𝐼
5(1.93)(2.0)3 (1000)4 (12)
ϒactual =
384(7580)(75)(150)3

ϒactual = 1.257 mm < 5.56 mm (SAFE IN DEFLECTION)

USE 75mm x 175mm for purlins