Você está na página 1de 1

Unit 25 / 205-213 DRAWN BY

Port Hacking Rd Michael Bussani


Miranda, NSW, 2228 DATE

AUSTRALIA 25 July 2010 WCCS-1 Residential Water Cooled Air Conditioning System
REVISION
T: +61 2 9522 0334 A with Zone Control
F: +61 2 9522 0337 SCALE Sheet 1 of 1
www.mjbcontrols.com.au N.T.S.

Low Water Temp Sensor

240VAC Sump Heater


1~
50Hz
Fuse
Zone N
A Active
NC
Zone 1
N Neutral NO
NC
Fan Neutral Zone 2
Evap Fan NO
E Fan High +12V
Fuse +12V
Fan Mid
GND
Fan Low 485A
AUX A/C 485B
LP
LP
HP
AUX Out HP
Pump SW
Note 2 Heat/RV A/C Safeties
Over Temp SW
Heater Element / RV Aux
Heat/RV Out

Comp A/C Legend:


Zone motor wired
dependant on zone
configuration.
Comp Run
e.g. motor open spring
close, spring open motor
R Start Cap close or motor open and
S motor close.
M
C
Compressor Note 2:
Programmable output to
customer specs.
(Voltage Free)

Copyright 2010 MJB Controls Pty Ltd. MJB Controls reserve the right to make alterations to this specification without written permission or notice.