Welcome to (n)Procure Tender Management System Page 1 of 11

DashBoard Document New Tenders Past Profile Archived LogOut


Library Tenders InProcess Tenders Data

WelCome Transrail ! (Transrail Lighting Limited )

Bid Submission Form

Current Tender Details


IFB / Tender Notice No : GETCO /Turnkey/400/220/66KV & 33KV Dholera GIS S/S/172 Tender ID: 381081
1) Package – 1 : Design, Engineering, manufacturing, Supply, erection, testing
and commissioning of 220/33KV GIS Equipment & material on Turnkey basis
including all civil works at Dholera GIS S/S. ( GPCL Scope) 2) Package – 2 :
Name of Work : ECV (INR): 0
Design, Engineering, manufacturing, Supply, erection, testing and commissioning
of 400/220/66KV GIS Equipment & material on Turnkey basis including all civil
works at Dholera GIS S/S. ( GETCO Scope for GUVNL)
Last Date & Time For Submission of Bid: 30/12/2019 16:00:00 Type Of Tender: open

SUPPLY-1
SUPPLY SCHEDULE

SUPPLY

Unit Freight, Packing


Sr. HSN Code for reference UNit Insurance Charges
Description Unit Qty. Unit Ex-Works rate and Forwarding F.O.R.Unit rate Total F.O.R.Cost in Rs.
No. only in Rs.
Charges
Supply and Erection of 220kV Switch Yard GIS Equipments considering 31mm/KV creepage distance due to marine atmosphere of site (as per respective Technical Specifications and relevant
special conditions ) suitable for 2 Bus system
220 KV Indoor GIS Equipment (Separate Enclosure for Each Phase shall be considered)
3- Ø 220 kV, 3150 A, 50
kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - Bus bar
Module comprising 1. 3 X
Single phase Voltage
transformer 220KV/ SQRT
3//110V/ SQRT 3 -( no. of
1.1 Sets 2 0 0
cores as per TS)
sagrigated from bus bar
unit 2. High speed/Fast
Acting Earthing switch 3.
Bus Disconnector with
Earthing switch 4. All other
items as per technical
specification

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 2 of 11

3- Ø 220 kV, 3150 A, 50


kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - Bus Coupler
bay Module comprising 1.
Circuit breaker 2. Current
transformer 3000-2000-
1.2 Set 1 0 0
1000/1A ( no. of cores as
per TS) -1 no for each
phase 3. Bus Disconnector
with one Earthing switch -
2 nos. 4. LCC Panel 5. All
other items as per
technical specification
3- Ø 220 kV, 3150 A, 50
kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - Bus
Sectionalizer bay Module
comprising 1.Circuit
breaker 2.Current
transformer 3000-2000-
1000/1A ( no. of cores as
per TS) -1 no for each
phase 3. Metering Current
transformer 3000-2000-
1.3 Set 1 0 0
1000/1A ( no. of cores as
per TS) -1 no for each
phase 4. 3 X Single phase
Metering Voltage
transformer 220KV/ SQRT
3//110V/ SQRT 3 -( no. of
cores as per TS) 5. Bus
Disconnector with one
Earthing switch -2 nos. 6.
LCC Panel 7. All other
items as per technical
specification

3- Ø 220 kV, 2000 A, 50


kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - 400/220 KV
Transformer bay Module
comprising 1. Circuit
breaker 2. Current
transformer 1500-1200-
600/1A ( no. of cores as
1.4 per TS)-1 no for each Sets 3 0 0
phase 3. Earthing Switch
4. Transformer side
Disconnector with one
maintenance earthing
switch 5. Bus Disconnector
with Earthing switch (Bus
side common earthing
switch for two bus) 6. Bus
Disconnector without
Earthing switch 7. SF6 Gas

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 3 of 11

Insulated Bus Duct (GIB)


from respective GIS bay
module up to SF6 to Air
insulated polymer housed
bushings including
required support
structures and other
accessories 8. LCC Panel
9. All other items as per
technical specification
3- Ø 220 kV, 2000 A, 50
kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - 220/33 KV
Transformer bay Module
comprising 1. Circuit
breaker 2. Current
transformer 1500-1200-
600/1A ( no. of cores as
per TS)-1 no for each
phase 3. Earthing Switch
4. Transformer side
Disconnector with one
maintenance earthing
switch 5. Bus Disconnector
1.5 Sets 8 0 0
with Earthing switch (Bus
side common earthing
switch for two bus) 6. Bus
Disconnector without
Earthing switch 7. SF6 Gas
Insulated Bus Duct (GIB)
from respective GIS bay
module up to SF6 to Air
insulated polymer housed
bushings including
required support
structures and other
accessories 8. LCC Panel
9. All other items as per
technical specification
220 KV Outdoor Equipments
Polymer housed Surge
Arrester 198kV, 10kA, Cl-3
2.1 Nos. 33 0 0
with structure and clamp
connectors
220kV High Bus Post
polymer housed Insulator
2.2 Nos. 33 0 0
with structure and clamp
connectors
220kV SF6 to Air insulated
polymer housed bushing
2.3 Nos. 33 0 0
1- Phase with structure
and clamp connectors
Metering Current
transformer 1500-1200-
2.4 Nos. 9 0 0
600/1A ( no. of cores as
per TS) -1 no for each

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 4 of 11

phase
3 X Single phase Metering
Voltage transformer
2.5 220KV/ SQRT 3//110V/ Nos. 9 0 0
SQRT 3 -( no. of cores as
per TS)
Supply and Erection of Galvanised Structure /Material for 220kV Switch Yard suitable to marine atmosphere (as per respective Technical Specifications and relevant special conditions ) suitable
for 2 Bus scheme. Only structure drawings of gantry structures shall be issued by GETCO. However, other details required for fabrication of gantry structures shall be developed by bidder at no
extra cost.
Gantry structures GI as
1 per BOM, Steel and A/B MT 65.6 0 0
part
Gantry structures GI as
- MT 4.2 0 0
per BOM, Bolt nut part
Lighting Mast structure -
2 MT 20.30208 0 0
Steel and A/B part
Lighting Mast structure -
- MT 0.81348 0 0
Bolt nut part
Note: The weight of LM structure may vary as per actual requirement of LMs.
Stringing of Flyover bus with Following Conductor for all the three phases with required Silicon Rubber Insulators, hardwares and accessories, spacers provided at every 5.0 mtr. interval
(Suitable for 350mm spacing)etc. complete as per relevant standards and approved drawings with Jumpers for continuous Bus Arrangement.
Break Up of Supply Items
for Erection of above work
4-B Rmtr. 787.5 0 0
1. AL59(61/3.50)
Conductor
Silicon Rubber Insulator
- No. 36 0 0
string-120KN
Double Tension H/W and
Acc with Sag Plate.suitable
- No. 9 0 0
for Twin AL59(61/3.50)
cond. and 120kN SRI
Double Tension H/W and
Acc without Sag
- Plate.suitable for Twin No. 9 0 0
AL59(61/3.50) cond. and
120kN SRI
Droppers (including required suspension string with hardware and accessories, if any) and Jumpers (including Equipment to Equipment) with Following conductor as per standards and
approved drawings with provision of required spacers (Suitable for 350mm spacing) at every 5.0 mtr. interval.
Break Up of Supply Items
for Erection of above work
5-B RMtr 330 0 0
1. AL59(61/3.50)
Conductor
Silicon Rubber Insulator
- No. 9 0 0
string-120KN
Single Suspension H/W
- and Acc. Twin AL59 No. 9 0 0
(61/3.50) Cond.
Spacers suitable for Twin
- AL59(61/3.50) Cond. No. 33 0 0
(350mm Spacing)
Fire Wedge Connectors
suitable for AL59(61/3.50)

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 5 of 11

Conductor to AL59
- No. 18 0 0
(61/3.50) conductor
Break Up of Supply Items
for Erection of above work
5-D RMtr 90 0 0
1. AL59(61/3.50)
Conductor
Fire Wedge Connectors
suitable for AL59(61/3.50)
- No. 99 0 0
Conductor to AL59
(61/3.50) conductor
Stringing of Earth Wire
with 7/3.15 GS wire with
required hardwares
accessories etc. complete
as per standards and
approved drawings (It
includes cost of Earthwire, Lump
6 1 0 0
hardwares and accessories sum
etc. all items required for
satisfactory functioning.
Any variation in quantities
shall be absorbed by
contractor.)- As per DSLP
requirement.
Supply and Erection of 33kV Switch Yard Equipments considering 31mm/KV creepage distance due to marine atmosphere of site (as per respective Technical Specifications and relevant special
conditions ) suitable for 2 Bus system
33kV Indoor GIS (Without vaccum interupter) Equipments
3- Ø 33 kV, 2500 A, 40
kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - Line bay
Module comprising 1.
Surge Arrester 30kV,
10kAp, Class II (To be
provided at Outside GIS
building) 2. Cable sealing
end with termination
arrangement/kit suitable
for connection of 3 Run
3CX500sq.mm Power
Cable (To be provided at
Outside GIS building) 3.
1.1 Sets 24 0 0
Circuit breaker 4. Current
transformer 1200-800-
400/1A ( no. of cores as
per TS) 5. Line side
Disconnector with one
maintenance earthing
switch 6. High speed/Fast
Acting Line Earthing switch
7. Metering Voltage
Transformer,
33KV/v3//110V/v3, ( no.
of cores as per TS) 8.
Metering Current
transformer 1200-800-
400/1A,( no. of cores as

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 6 of 11

per TS) 9. Bus


Disconnector with
Earthing switch (Bus side
common earthing switch
for two bus) 10. Bus
Disconnector without
Earthing Switch 11.LCC
Panel 12.All other items as
per technical specification
3- Ø 33 kV, 3150 A, 40
kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - Bus bar
Module comprising 1. 3 X
Single phase Voltage
transformer 33KV/ SQRT
3//110V/ SQRT 3C ( no. of
1.2 Sets 8 0 0
cores as per TS) -
segregated from bus bar
unit 2. High speed/Fast
Acting Earthing switch 3.
Bus Disconnector with
Earthing switch 4. All other
items as per technical
specification
3- Ø 33 kV, 3150 A, 40
kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - Bus Coupler
bay and Bus Sectionalizer
Module comprising 1.
Circuit breaker 2. Current
1.3 Sets 10 0 0
transformer 2500-1500/1A
( no. of cores as per TS) 3.
Bus Disconnector with one
Earthing switch -2 nos. 4.
LCC Panel 5. All other
items as per technical
specification

3- Ø 33 kV, 2500 A, 40
kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - 220/33 KV
Transformer bay Module
comprising 1. Surge
Arrester 30kV, 10kAp,
Class II (To be provided at
Outside GIS building) 2.
1.4 Circuit breaker 3. Current Sets 8 0 0
transformer 2500-1500/1A
( no. of cores as per TS) 4.
Transformer side
Disconnector with one
maintenance earthing
switch 5. Earthing switch
6.Bus Disconnector with
Earthing switch (Bus side
common earthing switch

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 7 of 11

for two bus) 7. Bus


Disconnector without
Earthing Switch 8. SF6
Gas Insulated Bus Duct
(GIB) from respective GIS
bay module up to SF6 to
Air insulated polymer
housed bushings including
required support
structures and other
accessories 9. LCC Panel
10. All other items as per
technical specification
3- Ø 33 kV, 2500 A, 40
kA-3 sec, metal enclosed
SF6 Gas Insulated
Switchgear - 33/11 KV
Transformer (5 MVA) bay
Module comprising 1.
Surge Arrester 30kV,
10kAp, Class II (To be
provided at Outside GIS
building) 2. Cable sealing
end with termination
arrangement/kit suitable
for connection of 1 Run
3CX185sq.mm Power
Cable (To be provided at
1.5 Outside GIS building) 3. Set 2 0 0
Circuit breaker 4. Current
transformer 200-100/1A
( no. of cores as per TS)
5.Transformer side
Disconnector with one
maintenance earthing
switch 6.Earthing switch 7.
Bus Disconnector with
Earthing switch (Bus side
common earthing switch
for two bus) 8. Bus
Disconnector without
Earthing Switch 9. LCC
Panel 10.All other items as
per technical specification
2 : 33kV Outdoor Equipments
66kV composite solid core
station post insulator with
2.1 Nos. 24 0 0
high level structure and
clamp connectors
66kV composite solid core
station post insulator with
2.2 Nos. 30 0 0
structure and clamp
connectors
Polymer housed Surge
Arrester 30kV, 10kAp,
2.3 Nos. 30 0 0
Class 3 with structure and
clamp connectors

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 8 of 11

33kV SF6 to Air insulated


polymer housed bushing
2.4 Nos. 24 0 0
1- Phase with structure
and clamp connectors
Supply and Erection of Galvanised Structure /Material for 33kV Switch Yard suitable to marine atmosphere (as per respective Technical Specifications and relevant special conditions ) suitable
for 2 Bus scheme. Only structure drawings of gantry structures shall be issued by GETCO. However, other details required for fabrication of gantry structures shall be developed by bidder at no
extra cost.
Gantry structures GI as
1 per BOM, Steel and A/B MT 25.6 0 0
part
Gantry structures GI as
- MT 1.8 0 0
per BOM, Bolt nut part
Stringing of Flyover bus with Following Conductor for all the three phases with required Silicon Rubber Insulators, hardwares and accessories, spacers provided at every 5.0 mtr. interval
(Suitable for 350mm spacing)etc. complete as per relevant standards and approved drawings with Jumpers for continuous Bus Arrangement.
Break Up of Supply Items
3.1 for Erection of above work
Rmtr. 1680 0 0
B 1. AL59(61/3.50)
Conductor
Silicon Rubber Insulator
- No. 96 0 0
string-120KN
Double Tension H/W and
Acc with Sag Plate.suitable
- No. 24 0 0
for Twin AL59(61/3.50)
cond. and 120kN SRI
Double Tension H/W and
Acc without Sag
- Plate.suitable for Twin No. 24 0 0
AL59(61/3.50) cond. and
120kN SRI
Spacers suitable for Twin
- AL59(61/3.50) Cond. No. 168 0 0
(350mm Spacing)
4. Droppers (including required suspension string with hardware and accessories, if any) and Jumpers (including Equipment to Equipment) with Following conductor as per standards and
approved drawings with provision of required spacers (Suitable for 350mm spacing) at every 5.0 mtr. interval.
Break Up of Supply Items
for Erection of above work
4-B RMtr 960 0 0
1. AL59(61/3.50)
Conductor
Silicon Rubber Insulator
- No. 24 0 0
string-120KN
Single Suspension H/W
- and Acc. Twin AL59 No. 24 0 0
(61/3.50) Cond.
Spacers suitable for Twin
- AL59(61/3.50) Cond. No. 96 0 0
(350mm Spacing)
Fire Wedge Connectors
suitable for AL59(61/3.50)
- No. 48 0 0
Conductor to AL59
(61/3.50) conductor

4-D Break Up of Supply Items RMtr 288 0 0


for Erection of above work

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 9 of 11

1. AL59(61/3.50)
Conductor
Fire Wedge Connectors
suitable for AL59(61/3.50)
- No. 72 0 0
Conductor to AL59
(61/3.50) conductor
Stringing of Earth Wire
with 7/3.15 GS wire with
required hardwares
accessories etc. complete
as per standards and
approved drawings (It
includes cost of Earthwire, Lump
5 1 0 0
hardwares and accessories sum
etc. all items required for
satisfactory functioning.
Any variation in quantities
shall be absorbed by
contractor.)- As per DSLP
requirement.
Supply and Laying of 3C X
185sq.mm 33kv
Aluminium XLPE power
cable with end termination
kit and three phase earth
link without SVL in ground
as per approved drawings
with providing and fixing
of brick and sand layer
covering the cable in any
6 Rmtr. 460 0 0
type of soil and Terminal
connection, clamp and
connectors, support
structure arrangement for
satisfactory functioning
Including required
terminations. Job includes
excavation of all type of
soils, Backfilling and
necessary civil work.

EOT Crane (For 220kV and


33KV and66kV GIS Hall) of
suitable capacity
(minimum 5T safe working
load) with single hook and
double girder
arrangement. Contractor
shall submit the capacity
7
calculation of the crane.
Nos. 2 0 0
There shall be provision
for lifting arrangement of
EOT crane for
maintenance purpose.
However, Contractor shall
submit the capacity
calculation of the crane
considering erection and

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 10 of 11

maintenance of largest
GIS component /
assembly.
EOT Crane of suitable
capacity (minimum 3T safe
working load) with single
hook and double girder
arrangement for Store
building. Contractor shall
8 Nos. 1 0 0
submit the capacity
calculation of the crane.
There shall be provision
for lifting arrangement of
EOT crane for
maintenance purpose.
Visual Monitoring System
(VMS) as per technical
Lump
9 specification. (For Total 1 0 0
sum
scope of Project i.e Part-1
and 2 scope)
Ventilation system (for maintaining positive pressure) shall be provided for following building as per Technical Specifications
Lump
1 220KV GIS Hall 1 0 0
sum
Lump
2 33KV-66KV GIS Hall 1 0 0
sum
Fire Detection and Alarm
System as per Technical
Lump
10 Specification (For Total 1 0 0
sum
scope of Project i.e Part-1
and 2 scope)
Supply and installation of
Portable and wheel/trolley
mounted fire extinguishers
for Control room, 220 and
33kV GIS Hall, Relay panel
room of GIS
11 No. 10 0 0
Hall,Transformers,Reactors
and other Strategic
locations as per Technical
Specification. 1) Dry
chemical powder type of 9
Kg. capacity.
2) Dry chemical powder
- No. 6 0 0
type of 25 Kg. capacity.
3) Dry chemical powder
- No. 6 0 0
type of 50 Kg. capacity.
4) Carbon dioxide ( CO2)
- gas type of capacity 6.5 No. 15 0 0
Kg. capacity
5) Carbon dioxide (CO2)
- gas type of capacity 22.5 No. 10 0 0
Kg. capacity
6) Mechanical Foam type
- No. 6 0 0
of capacity 9 LT.

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019
Welcome to (n)Procure Tender Management System Page 11 of 11

7) Mechanical Foam type


- No. 6 0 0
of capacity 50 LT.
Supply and installation of Tower/Split Air Conditioner Machine at following Locations.
3 Ton Capacity Split AC (5
star rating and reputed
1 Nos. 7 0 0
make) 1. 1) LCC Room of
220kV GIS

- 2) LCC Room of 33kV GIS Nos. 7 0 0


1.5 Ton Capacity Split AC
2 (5 star rating and reputed Nos. 2 0 0
make) 1. 1) Testing Lab

- 2) Admin. Offices Nos. 7 0 0


3) Reception cum Waiting
- Nos. 3 0 0
Room

- 4) Security Officer Cabin Nos. 1 0 0


3 Ton Capacity Tower AC
(3 star rating and reputed
3 Nos. 2 0 0
make) 1) SCADA Control
Room

- 2) Conference Room Nos. 2 0 0

- 3) Meeting room Nos. 1 0 0

0
zero

Previous Edit Verify Data Encryption Save and Submit

Create secondary partner | View secondary partners | Joint Venture Tenders | Registration For SAP | Accept Joint Venture

Server Time : 22/11/2019 18:14:24

https://getco.nprocure.com/asp/tms/SubmitForm.aspx 22-11-2019