Você está na página 1de 6

DRAFT IN

WIDE CIRCULATION
DOCUMENT DESPATCH ADVICE

Reference Date
CED 50/T- 2, 74, 77 01 05 2006
TECHNICAL COMMITTEE:

Plastic Piping System Sectional Committee, CED 50


ADDRESSED TO :

1. Interested Members of Civil Engineering Division Council, CEDC


2. All Members of CED 50 & CED 50:1
3. All others interested

Dear Sir (s),

Please find enclosed the following draft amendments:

Doc No. Title

CED 50 (7386) Draft Amendment No. 5 to IS 4984:1995 `Specification for High


Density Polyethylene Pipes for Potable Water Supplies’
CED 50 (7396) Draft Amendment No. 2 to IS 14885:2001 Specification for
Polyethylene pipes for supply of gaseous fuel
CED 50 (7395) Draft Amendment No. 1 to IS 15450:2004 `Specification for
Polyethylene/aluminium/polyethylene composite pressure pipes
for hot and cold water supplies’

Kindly examine the draft amendments and forward your views stating any difficulties which you are likely
to experience in your business or profession, if these are finally adopted as amendments to National Standards.

Last Date for comments : 31 05 2006

Comments if any, may please be made in the format as given overleaf and mailed to the undersigned at the
above address.

In case no comments are received or comments received are of editorial nature, you will kindly
permit us to presume your approval for the above documents as finalized. However, in case of
comments of technical in nature are received then these may be finalized either in consultation with the
Chairman, Sectional Committee or referred to the Sectional Committee for further necessary action if so
desired by the Chairman, Sectional Committee.

The document is also hosted on BIS website www.bis.org.in.

Thanking you, Yours faithfully,

(J.C. Arora)
Sc `E’ & Head (Civil Engg.)
Encl: as above email : ced@bis.org.in
¾µÖ֯֍ú ¯Ö׸ü“ÖÖ»Ö−Ö ´ÖÃÖÖî¤üÖ

Æü´ÖÖ¸üÖ ÃÖÓ¤ü³ÖÔ : ÃÖ߇ԛüß 50/™üß - 2, 74, 77 01 05 2006


ŸÖú−Öߍúß ÃÖ×´Ö×ŸÖ : ¯»ÖÖÛÙüú ¯ÖÖ‡Ø¯ÖÖ ¯Ö¨ü×ŸÖ ×¾ÖÂÖµÖ ÃÖ×´ÖןÖ, ÃÖ߇ԛüß 50
____________________________________________________
¯ÖÏÖ¯ŸÖúŸÖÖÔ :

… ×ÃÖ×¾Ö»Ö ‡Ó•Öß×−ÖµÖ¸üß ×¾Ö³ÖÖÖ ¯Ö׸üÂÖ¤ü êú ºþ×“Ö ¸üÖ−Öê ¾ÖÖ»Öê ÃÖ¤üõÖ


2 ÃÖ߇ԛüß 50 ‹¾ÖÓ ÃÖ߇ԛüß 50:1 êú ÃÖ³Öß ÃÖ¤üõÖ
3 ºþ×“Ö ¸üÖ−Öê ¾ÖÖ»Öê †−µÖ ×−֍úÖµÖ

´ÖÆüÖê¤üµÖ (µÖÖë),

×−Ö´−Ö×»Ö×ÖŸÖ ÃÖÓ¿ÖÖê¬Ö−Ö ÃÖ»ÖӐ−Ö Æîü :

ÃÖ߇ԛüß 50 (7386) IS 4984:1995 êú ×»Ö‹ ÃÖÓ¿ÖÖê¬Ö−Ö ÃÖӏµÖÖ 5 úÖ ´ÖÃÖÖî¤üÖ


ÃÖ߇ԛüß 50 (7396) IS 14885:2001 êú ×»Ö‹ ÃÖÓ¿ÖÖê¬Ö−Ö ÃÖӏµÖÖ 2 úÖ ´ÖÃÖÖî¤üÖ
ÃÖ߇ԛüß 50 (7395) IS 15450:2004 êú ×»Ö‹ ÃÖÓ¿ÖÖê¬Ö−Ö ÃÖӏµÖÖ 1 úÖ ´ÖÃÖÖî¤üÖ

éú¯ÖµÖÖ ‡−Ö ´ÖÃÖÖî¤ÖêÓ ü úÖ †¾Ö»ÖÖêú−Ö ú¸ëü †Öî¸ü †¯Ö−Öß ÃÖ´´ÖןֵÖÖÑ µÖÆü ²ÖŸÖÖŸÖê Æãü‹ ³Öê•Öë ׍ú µÖפü µÖê ´ÖÃÖÖî¤üê ´ÖÖ−֍ú êú ÃÖÓ¿ÖÖê¬Ö−Ö êú ºþ¯Ö
´Öë ¯ÖύúÖ×¿ÖŸÖ ÆüÖê ŸÖÖê ‡−Ö ¯Ö¸ü †´Ö»Ö ú¸ü−Öê ´Öë †Ö¯Öêú ¾µÖ¾ÖÃÖÖµÖ †£Ö¾ÖÖ úÖ¸üÖê²ÖÖ¸ü ´Öë ŒµÖÖ úךü−ÖÖ‡µÖÖÑ †Ö Ã֍úŸÖß Æïü …

ÃÖ´´ÖןֵÖÖÑ ³Öê•Ö−Öê úß †Ó×ŸÖ´Ö ×ŸÖ×£Ö 31 05 2006

ÃÖ´´Ö×ŸÖ µÖפü úÖê‡Ô ÆüÖê ŸÖÖê éú¯ÖµÖÖ †¬ÖÖêÆüßÖցָüß úÖê ˆ¯Ö¸ü×»Ö×ÖŸÖ ¯ÖŸÖê ¯Ö¸ü ÃÖ»ÖӐ−Ö ±úÖê´Öì™ü ´Öë ³Öê•Öë …

µÖפü úÖê‡Ô ÃÖ´´Ö×ŸÖ ¯ÖÏÖ¯ŸÖ −ÖÆüà ÆüÖêŸÖß Æîü †£Ö¾ÖÖ ÃÖ´´Ö×ŸÖ ´Öë êú¾Ö»Ö ³ÖÖÂÖÖ ÃÖ´²Ö−¬Öß ¡Öã×™ü Æãü‡Ô ŸÖÖê ˆ¯Ö¸üÖêŒŸÖ ¯ÖÏ»ÖêÖ úÖê µÖ£ÖÖ¾ÖŸÖ †Ó×ŸÖ´Ö ºþ¯Ö
¤êü פüµÖÖ •ÖÖ‹ÖÖ … µÖפü ÃÖ´´Ö×ŸÖ ŸÖú−Öߍúß ¯Öύéú×ŸÖ úß Æãü‡Ô ŸÖÖê ×¾ÖÂÖµÖ ÃÖ×´Ö×ŸÖ êú †¬µÖÖ êú ¯Ö¸üÖ´Ö¿ÖÔ ÃÖê †£Ö¾ÖÖ ˆ−֍úß ‡“”ûÖ ¯Ö¸ü †ÖÖê úß
úÖµÖÔ¾ÖÖÆüß êú ×»Ö‹ ×¾ÖÂÖµÖ ÃÖ×´Ö×ŸÖ úÖê ³Öê•Öê •ÖÖ−Öê êú ²ÖÖ¤ü ¯ÖÏ»ÖêÖ úÖê †Ó×ŸÖ´Ö ºþ¯Ö ¤êü פüµÖÖ •ÖÖ‹ÖÖ …

µÖÆü ¯ÖÏ»ÖêÖ ³ÖÖ¸üŸÖßµÖ ´ÖÖ−֍ú ²µÖæ¸üÖê úß ¾Öî²ÖÃÖÖ‡™ü ¯Ö¸ü ³Öß Æîü …

¬Ö−µÖ¾ÖÖ¤ü …

(•Öê. ÃÖß. †¸üÖê›ÍüÖ)


×−Ö¤êü¿Öú ‹¾ÖÓ ¯ÖÏ´ÖãÖ( (×ÃÖ×¾Ö»Ö ‡Ó•Öß×−ÖµÖ¸üß)
email : ced@bis.org.in

ÃÖ»ÖӐ−Ö : ˆ¯Ö׸ü×»Ö׏֟Ö
Doc: CED 50( 7396)

DRAFT FOR COMMENTS ONLY


(Not to be reproduced without the permission of BIS or used as an AMENDMENT)

________________________________________________________________
Plastic Piping Systems Last date for receipt of
Sectional Committee, CED 50 Comments is 31 May 2006
________________________________________________________________

DRAFT AMENDMENT NO. 2


TO
IS 14885:2001 POLYETHYLENE PIPES FOR THE SUPPLY OF GASEOUS FUELS –
SPECIFICATION

[Page 15, Clause G-2.3 a)] – Substitute the following for the existing:

`size of mandrel shall be as given in Table 11A.’

Table 11A Mandrel Size


[Clause G-2.3 a)]

Sl.No. Nominal Outside Diameter Minimum Radius of


of Pipe, mm Mandrel, mm
(1) (2) (3)
i) 16-20 12 mm
ii) 25-50 16 mm
iii) 63-110 19 mm
iv) 125-200 25 mm
v) 225-315 25 mm
vi) 355-400 32 mm

(CED 50)
Doc: CED 50( 7395 )

DRAFT FOR COMMENTS ONLY


(Not to be reproduced without the permission of BIS or used as an AMENDMENT)

________________________________________________________________
Plastic Piping Systems Last date for receipt of
Sectional Committee, CED 50 Comments is 31 May 2006
________________________________________________________________

DRAFT AMENDMENT NO. 1


TO
IS 15450:2004 POLYETHYLENE/ALUMINIUM/POLYETHYLENE
COMPOSITE PRESSURE PIPES FOR HOT AND COLD
WATER SUPPLIES – SPECIFICATION

[Page 4, Table 5, sl.no. ii) and iii), col. (1) to ( 5] – Substitute the following for the
existing:

(1) (2) (3) (4) (5)

ii) 1014 20 3.00 1.00


60 2.50 10.00

iii) 1216 20 3.00 1.00


60 2.50 10.00

(Page 10, Clause E-2, line 1) – Insert `individually’ after `samples’.

(Page 10, Fig. 3) – Substitute the following Fig. for the existing:

----------------
Fig. 3
--------------

(CED 50)
'" '-

""
'"
""

""

"'"

Fig 3 Schematic presentation of the pipe ring test showing the Aluminium weld
at 90° to the tensile axis
Doc: CED 50 (7386)

DRAFT FOR COMMENTS ONLY


(Not to be reproduced without the permission of BIS or used as an AMENDMENT)

____________________________________________________________________
Plastic Piping Systems Last date for receipt of
Sectional Committee, CED 50 Comments is 31 May 2006
____________________________________________________________________

DRAFT AMENDMENT NO. 5


TO
IS 4984:1995 HIGH DENSITY POLYETHYLENE PIPES FOR WATER SUPPLY –
SPECIFICATION

(Fourth Revision)

(Page 7, Table 6, Col (4).Title) – Insert ‘h’ at the end.

(CED 50)

Você também pode gostar