Escolar Documentos
Profissional Documentos
Cultura Documentos
PVsyst TRIAL
Simulation variant :
Simulation parameters
New simulation variant
System type
Azimuth
30/11/19 20h24
PVsyst TRIAL
PV Array Characteristics
PV module
Original PVsyst database
Number of PV modules
Total number of PV modules
Si-mono Model
Manufacturer
In series
Nb. modules
Somera VSM.72.370.05
Vikram Solar
6 modules
18
In parallel
Unit Nom. Power
3 strings
370 Wp
Array global power Nominal (STC) 6.66 kWp At operating cond. 6.07 kWp (50°C)
Array operating characteristics (50°C) U mpp 214 V I mpp 28 A
Total area Module area 34.9 m²
PVsyst TRIAL
Manufacturer Exide Classic
Battery Pack Characteristics Nb. of units 8 in series x 8 in parallel
Voltage 96 V Nominal Capacity 1408 Ah
Discharging min. SOC 20.0 % Stored energy 108.1 kWh
Temperature Fixed (24°C)
Controller Model Universal controller with MPPT converter
Technology MPPT converter Temp coeff. -5.0 mV/°C/elem.
Converter Maxi and EURO efficiencies 97.0 / 95.0 %
Battery Management control Threshold commands as SOC calculation
Charging SOC = 0.92 / 0.75 i.e. approx. 106.5 / 99.1 V
Discharging SOC = 0.20 / 0.45 i.e. approx. 93.0 / 96.5 V
PVsyst TRIAL
PV Array loss factors
Thermal Loss factor Uc (const) 20.0 W/m²K Uv (wind) 0.0 W/m²K / m/s
Wiring Ohmic Loss Global array res. 42 mOhm Loss Fraction 0.5 % at STC
Serie Diode Loss Voltage Drop 0.7 V Loss Fraction 0.3 % at STC
Module Quality Loss Loss Fraction -0.8 %
Module Mismatch Losses Loss Fraction 1.0 % at MPP
Strings Mismatch loss Loss Fraction 0.10 %
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.85 30/11/19 Page 3/7
PVsyst TRIAL
PV Array Nb. of modules 18 Pnom total 6.66 kWp
Battery Model Enersol 250 Technology Lead-acid, vented, plates
Battery Pack Nb. of units 64 Voltage / Capacity 96 V / 1408 Ah
User's needs Daily household consumers Constant over the year Global 9149 kWh/year
PVsyst TRIAL
PVsyst TRIAL 90
75
Shading loss: 1 %
Shading loss: 5 %
11h
Shading loss: 10 %
Shading loss: 20 %
Shading loss: 40 %
Iso-shadings diagram
Bokaro
Beam shading factor (linear calculation) : Iso-shadings curves
9h 5
Sun height [[°]]
15h
6
45
7
8h
PVsyst TRIAL
16h
30
7h
17h
15 6h
Behind Behind
the plane the plane
0
-120 -90 -60 -30 0 30 60 90 120
Azimuth [[°]]
PVsyst TRIAL
PV Array Nb. of modules 18 Pnom total 6.66 kWp
Battery Model Enersol 250 Technology Lead-acid, vented, plates
Battery Pack Nb. of units 64 Voltage / Capacity 96 V / 1408 Ah
User's needs Daily household consumers Constant over the year Global 9149 kWh/year
Daily household consumers, Constant over the year, average = 25.1 kWh/day
Annual values
PVsyst TRIAL
Fridge / Deep-freeze 1 22 Wh/day 1505 Wh/day
Washing Machine 1 2 Wh/day 1200 Wh/day
Fans 1 500 W tot 8 h/day 4000 Wh/day
Stand-by consumers 24 h/day 24 Wh/day
Total daily energy 25067 Wh/day
Hourly profile
3500
[%]
3000
enegy
2500
2000
daily
1500
of
1000
Fraction
500
PVsyst TRIAL
0
0 3 6 9 12 15 18 21 24
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.85 30/11/19 Page 5/7
PVsyst TRIAL
PV Array Nb. of modules 18 Pnom total 6.66 kWp
Battery Model Enersol 250 Technology Lead-acid, vented, plates
Battery Pack Nb. of units 64 Voltage / Capacity 96 V / 1408 Ah
User's needs Daily household consumers Constant over the year Global 9149 kWh/year
Normalized productions (per installed kWp): Nominal power 6.66 kWp Performance Ratio PR and Solar Fraction SF
PVsyst TRIAL
8 1.2
Lu : Unused energy (battery full) 0.3 kWh/kWp/day PR : Performance Ratio (Yf / Yr) : 0.649
1.1
7 Lc : Collection Loss (PV-array losses) 1.27 kWh/kWp/day SF : Solar Fraction (ESol / ELoad) : 0.976
Ls : System losses and battery charging 0.41 kWh/kWp/day 1.0
[kWh/kWp/day]
0.8
5
0.7
Energy
4 0.6
0.5
Normalized
3
0.4
2 0.3
0.2
1
0.1
0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
E_Avail
kWh
EUnused
kWh
E_Miss
kWh
E_User
kWh
E_Load
kWh
SolFrac
PVsyst TRIAL
September 130.4 118.9 669.5 0.0 90.8 661.2 752.0 0.879
October 142.2 143.9 806.9 0.0 26.0 751.1 777.1 0.967
November 129.7 148.2 841.5 13.6 0.0 752.0 752.0 1.000
December 127.9 155.4 895.3 43.9 0.0 777.1 777.1 1.000
PVsyst TRIAL
PV Array Nb. of modules 18 Pnom total 6.66 kWp
Battery Model Enersol 250 Technology Lead-acid, vented, plates
Battery Pack Nb. of units 64 Voltage / Capacity 96 V / 1408 Ah
User's needs Daily household consumers Constant over the year Global 9149 kWh/year
50
Effective energy at the output of the array [kWh/day]
40
PVsyst TRIAL
30
20
10
0
0 1 2 3 4 5 6 7 8
Global incident in coll. plane [kWh/m².day]
PVsyst TRIAL
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.85 30/11/19 Page 7/7
PVsyst TRIAL
PV Array Nb. of modules 18 Pnom total 6.66 kWp
Battery Model Enersol 250 Technology Lead-acid, vented, plates
Battery Pack Nb. of units 64 Voltage / Capacity 96 V / 1408 Ah
User's needs Daily household consumers Constant over the year Global 9149 kWh/year
12154 kWh
-2.59%
-0.60%
IAM factor on global
PV conversion
-5.47%
-0.04%
0.00%
0.00%
Effective energy at the output of the array
PVsyst TRIAL
-1.03% Battery Self-discharge Current
8929 kWh Energy supplied to the user