Premier 48/88/168
Issue 6
Contents Premier 48, 88 & 168 Installation Manual
Contents
Contents .................................................................. 2 5. Programming the Control Panel ...................... 31
1. History.................................................................. 4 Introduction ............................................................ 31
Copying and Pasting.............................................. 33
2. System Overview ................................................ 5
Log Off Engineer .................................................... 33
System Architecture ................................................. 5
Resetting the Engineers Code (User 00)............... 33
Control Panels .......................................................... 5
Remote Keypads ...................................................... 6 5.1 Zone Setup ...................................................... 34
Zone Expanders........................................................ 6 Zone Types ............................................................. 35
Output Expanders..................................................... 6 Zone Attributes 1 .................................................... 36
Communicators ........................................................ 6 Zone Attributes 2 .................................................... 36
Other Devices ........................................................... 7 Attributes for Moment or Latch Keys..................... 37
Attributes for Custom Zones.................................. 37
3. Installation ........................................................... 8
Zone Areas.............................................................. 37
Installation Sequence............................................... 8
Zone Text ................................................................ 37
Control Panel............................................................ 8
Zone Chime ............................................................ 37
Power Supply Ratings ............................................ 12
Remote Test Enable ............................................... 37
Connecting AC Mains............................................. 12
Zone Wiring ............................................................ 38
Connecting Batteries.............................................. 12
DD 243 .................................................................... 38
Connecting Devices to the Network ...................... 13
Remote Keypads .................................................... 15 5.2 Area Programming.......................................... 39
8XP Zone Expander ................................................ 16 Timers ..................................................................... 39
4 XP Zone Expander ............................................... 17 Arming Modes ........................................................ 40
iProx Module........................................................... 17 Area Arm Suites...................................................... 40
60IXD Zone Expander ............................................. 18 Area Suite Text ....................................................... 41
OP16 Output Expander........................................... 19 Suite Arm Modes .................................................... 41
Zone and Output Numbering ................................. 20 Area Options........................................................... 42
Zone Connections .................................................. 21 Time Arm Area ........................................................ 45
Auxiliary Tamper Connections............................... 22 Area Text................................................................. 46
Speaker Connections ............................................. 22 5.3 Global Options ................................................ 47
External Sounder Connections .............................. 22 System Timers........................................................ 47
Panel Outputs 1 - 5 ................................................. 23 System Config. ....................................................... 48
Digicom Outputs 1 - 8............................................. 23 System Options ...................................................... 51
2-Wire Smoke Detector .......................................... 24 Monitor Hardware................................................... 52
Expander Auxiliary Input ........................................ 24 Control Timers........................................................ 52
Plug-on Communicators ........................................ 25 System Text ............................................................ 53
RP9 Radio-Pad........................................................ 26 Part Arm Text .......................................................... 53
GSM Module ........................................................... 26 Holiday Dates ......................................................... 54
AV Module ............................................................... 26 Speaker Tones........................................................ 54
ComIP Module ........................................................ 26 PC Output Text ....................................................... 55
PC-Com................................................................... 27 Custom O/P Text .................................................... 55
UNI-Com ................................................................. 27
5.4 Keypad Setup .................................................. 56
PRINT-Com ............................................................. 27
Keypad Areas ......................................................... 57
RPD-Com ................................................................ 27
Keypad Zone Mapping ........................................... 57
GSM-Com................................................................ 27
Keypad Options...................................................... 57
Connecting a Computer ......................................... 27
Keypad Speaker Volume........................................ 57
Connecting a Printer .............................................. 27
Keypad Sounder Options....................................... 57
4. Commissioning and Troubleshooting ............. 28
5.5 Expander Setup............................................... 58
Commissioning....................................................... 28
Expander Areas ...................................................... 59
Trouble-Shooting.................................................... 28
Expander Location Text ......................................... 59
Reset and Service Messages................................. 30
Expander Auxiliary Input ........................................ 59
Expander Speaker Volume..................................... 59
Expander Sounder Options.................................... 59
2 INS176
Contents Premier 48, 88 & 168 Installation Manual
INS176 3
System Overview Premier 48, 88 & 168 Installation Manual
1. History
This section shows the key milestones in the product development history, helping to identify when particular features were
implemented.
4 INS176
Premier 88 & 168 Installation Manual System Overview
2. System Overview
System Architecture
8 to 48 Zones (Premier 48) 4 Keypads (Premier 48) 2 Output Modules (Premier 48) 4 Expanders (Premier 48)
8 to 88 Zones (Premier 88) 8 Keypads (Premier 88) 4 Output Modules (Premier 88) 8 Expanders (Premier 88)
8 to 168 Zones (Premier 168) 16 Keypads (Premier 168) 8 Output Modules (Premier 168) 16 Expanders (Premier 168)
16 Programmable
100mA Outputs 8 Zone Inputs
2 Zone 1Programmable 2 Zone 1Programmable
8 Zone Inputs Inputs 100mA Output Inputs 100mA Output
Power Power
Network No
Address
Zones
Network No
Address
Zones
8 Programmable
Premier
Power Power
100mA Outputs
Premier
Info. Info.
Ready Ready
Omi Service Omit Service
8 Programmable Speaker
48/88/168
1 2 abc 3 def Omit Reset 1 2 abc 3 def Omit Reset
Modem
Control Panels
Premier 48 Premier 168
• 8 fully programmable Double Pole or End Of Line zones • 8 fully programmable Double Pole or End Of Line zones
• Expandable to 48 zones via keypads and zone expanders • Expandable to 168 zones via keypads and zone expanders
• 1 x 4-wire data network (standard 7/0.2 alarm cable) • 2 x 4-wire data network (standard 7/0.2 alarm cable)
• Up to 4 keypads and 4 zone expanders • Up to 16 keypads and 16 zone expanders (8 per network)
• Up to 2 output modules • Up to 8 output modules (4 per network)
• 4 independent areas each with 3 part arms • 16 independent areas each with 3 part arms
• 4 area arm suites • 16 area arm suites
• 25 programmable User codes • 200 programmable User codes
• 500 Event Log (time & date stamped) • 2000 Event Log (time & date stamped)
• 2 programmable panel outputs (2 x 1A ) • 5 programmable panel outputs (4 x 1A & 3A relay)
• 1.5 Amp power supply • 2.0 Amp power supply
INS176 5
System Overview Premier 48, 88 & 168 Installation Manual
GSM Module
• Provides a GSM telephone path for Premier Digital
Communicators
• Sends SMS text messages to mobile phones
• Arm, Disarm, Reset the alarm, turn outputs on and off,
omit zones and send messages to the control panel
using SMS text messages
• 9600-baud modem for remote uploading and
downloading using the Wintex UDL software and a PC
6 INS176
Premier 48, 88 & 168 Installation Manual System Overview
Other Devices
PC-Com
• For connecting a PC to the control panel via an RS232
Serial port allowing local uploading and downloading using
Wintex UDL software
USB-Com
• For connecting a PC to the control panel via a USB 1.0 or
2.0 port allowing local uploading and downloading using
Wintex UDL software
UNI-Com
• For connecting a serial device i.e. PC modem or mobile
phone to the control panel
PRINT-Com
• For connecting a serial printer to the control panel
RPD-Com
• For connecting a RP9 Radio-Pad to the control panel
GSM-Com
• For connecting a ComGSM to the control panel
X10-Com
• For controlling X10 enabled devices on the ring main.
External Sounders
Texecom supply a range of external sounders
INS176 7
Installation Premier 48, 88 & 168 Installation Manual
3. Installation
Installation Sequence Control Panel
Before attempting to install the alarm system, read this
Mounting
section. Once you have an overall understanding of the
installation sequence, carefully work through each step. Mount the control panel on a flat, plumb wall using at least
three screws of appropriate size.
1: Design the Layout
Make a rough sketch of the premises to get an idea of where
the alarm detection devices, keypads, zone expanders etc.
! It is essential to ensure that none of the fixing slots or
cable entries are accessible after fixing.
are to be located. Mains cabling must be secured (e.g. with a cable tie) to
2: Mounting the Panel one of the anchor points provided.
The control panel should be mounted in a dry area close to
an unswitched AC power source and the incoming telephone Wiring the Control Panel
line (if using a communicator).
WARNING: ELECTRICITY CAN KILL
! You must complete all wiring before connecting the
battery or applying AC mains to the control panel. BEFORE connecting the control panel ALWAYS
disconnect the supply at the consumer unit.
3: Install the Keypads and Zone Expanders
Mount and connect the keypads, zone expanders and output If in ANY doubt consult a qualified electrician.
modules to the control panel (see page 13 for wiring details).
4: Install the Alarm Detection Devices
Install the detection devices, PIR’s, Contacts, PA Buttons etc.
" IMPORTANT SAFETY INFORMATION. HAZARDOUS
VOLTAGES INSIDE, NO USER SERVICEABLE PARTS,
and connect them to the control panel (see page 21 for wiring NO USER ACCESS.
details).
5: Install the External Sounder ! ONLY connect the mains supply to the mains terminal
block, NEVER connect the mains supply directly to the
Install the external sounder and connect to the control panel PCB.
(see page 22 for wiring details).
ALWAYS refer to National Wiring Regulations when
6: Other Wiring conducting installation.
Complete all other wiring including speakers, telephone line
and output connections etc. (see pages 22 - 23 for details). An appropriate and readily accessible disconnection
device (e.g. an unswitched fused spur) MUST be
7: Applying Power to the Control Panel provided as part of the installation.
Once steps 1 to 6 are completed, power can be applied to
the control panel. The disconnection device must NOT be fitted in a
flexible cord.
When applying power for the first time, the factory default
settings must be loaded (see page 28 for details). Power Where identification of the neutral in the mains supply
should always be connected in the following order: is NOT possible a two-pole disconnection device
• Connect the red battery lead to the positive terminal of MUST be used.
the battery and then connect the black battery lead to The building mains supply MUST incorporate
the negative terminal appropriate short-circuit backup protection (e.g. a fuse
or circuit breaker) of High Breaking Capacity (HBC, at
! The panel will only become ‘live’ when the AC
Mains is connected or the ‘Battery Kick-start’
least 1500A).
button is pressed. Use mains cable of adequate carrying capacity for the
rated current (i.e. at least 0.75mm2).
• Connect the AC mains
For a complete list of factory default settings, see the Premier
Quick Reference supplied with your panel.
8: Programming the Control Panel
Please refer to section 5 for instruction on programming the
control panel.
9: Testing the System
Test the system thoroughly to ensure that all features and
functions operate as required (see page 89 for details).
8 INS176
Premier 48, 88 & 168 Installation Manual Installation
BT
Cable
1.5 Amp Mains Entry
T
Transformer R
T1
R1
Plug-on
Digimodem
(Com300,
Com2400 or
Box
Tamp
ComISDN)
A.C.
OP5
BATT
L/M OP4+
Kick
Start
R/R OP3+
DC+ OP2-
DC- OP1-
-
1 Spk
Com 1
2 JP6 Spk+
DIGICOM OUTPUTS
Com 2
3 Aux
4 JP2 Tamp
Network 2
1Amp
1Amp
6 Bell -
Circuit Board 7
8
F3 F5 F1 Tamp
0v
Aux 12v
1Amp
Load Strb -
Jp9 Defaults
Expansion
Heartbeat
Engineer Tx1 Rx1 Tx2 Rx2 JP7
Remote
Bell/Strb - 1Amp
V
100mA =
1 Amp
F4
+ - T R + - T R + - A T A T A T A T A T A T A T A T
NETWORK 1 NETWORK 2 Aux 12v Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
Cable
Entries
Cable
Space for
Entries
1 x 7Ah Battery
2 x 7Ah Batteries
or 1 x 17Ah Battery
INS176 9
Installation Premier 48, 88 & 168 Installation Manual
14 13
Box
1 Tamp
A.C.
OP5
BATT
2
L/M
Kick
OP4+ 12
Start
R/R OP3+
3 DC+ 16 OP2-
DC- OP1-
-
1 Spk
Com 1
11
2 Spk+
JP6
17
DIGICOM OUTPUTS
Com 2
3 Aux
4 JP2 Tamp 10
4
5 +12v
Network 1
Network 2
23
1Amp
1Amp
6 Bell -
7 F3 F5 F1 Tamp 9
8 19 20 0v
Aux 12v
1Amp
Load
Defaults
21 Strb -
Expansion
5 Tx1 Rx1 Tx2 Rx2 JP7
Heartbeat
Engineer
18
Bell/Strb - 1Amp
V
Remote
100mA = 22
1 Amp
F4
+ - T R + - T R + - A T A T A T A T A T A T A T A T
NETWORK 1 NETWORK 2 Aux 12v Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
6 7 8
10 INS176
Premier 48, 88 & 168 Installation Manual Installation
INS176 11
Installation Premier 48, 88 & 168 Installation Manual
7 Ah Standby Battery + +
_ Battery
Max Power Grade 2 – Grade 3 – Grade 3 –
Available Rating Rating Rating 12V 17Ah Battery
-
from control AC Fail AC Fail
panel signalled as signalled as OR
AC Fail Fault
2A 580mA 580mA 290mA + +
_ Battery
17 Ah Standby Battery 12V 7Ah Battery
Max Power Grade 2 – Grade 3 – Grade 3 – -
Available Rating Rating Rating
from control AC Fail AC Fail
panel OR
signalled as signalled as
If not installing to PD6662: 2004
AC Fail Fault
2A 1.25A 1.25A 710mA + +
_ Battery
When calculating the current consumption of the system you 12V 7Ah Battery
must include the current taken by the control panel and all -
the devices that it powers. If the total current exceeds the
“Rated Output” for the grade you are installing to then an +
additional power supply is required.
12V 7Ah Battery
-
Connecting AC Mains
The AC Mains supply is connected to a 3 way ‘Euro Type’
fused terminal block, which is fitted with a 125mA or 500mA
fuse.
L
E
To transformer
N
12 INS176
Premier 48, 88 & 168 Installation Manual Installation
Keypads, zone expanders and output modules are all connected Distances of up to 1km can be achieved between the control
to the same network terminals located at the bottom left hand panel and a device. However, a power supply must be installed
corner of the control panel and may be connected serially (daisy close to the device to power it locally, this will help to
chain), in parallel (star) or any combination of the two (see overcome voltage drop caused by the long cable run.
Figure 1, page 14 for details).
Devices can be connected using 4-core cable. However, it is LED Status ‘T’ Wire OUT ‘T’ Wire IN
recommended that 6 or 8-core cable is used as the spare cores can
Red LED Flashing Normal Normal
be used to ‘Double Up’ on the power connections if needed.
Red LED On Panel Fault Cable Short
! Standard 7/0.2 alarm cable can be used for most
installations. However, under certain conditions it may
Red LED Off Panel Fault Panel Fault
INS176 13
Installation Premier 48, 88 & 168 Installation Manual
14 INS176
Premier 48, 88 & 168 Installation Manual Installation
Switch 1 2 3 4
Piezo
4 Unmapped Unmapped
SPK O/P
+ -
T R
Sounder 5* Unmapped Unmapped
NETWORK
6* Unmapped Unmapped
T
Zone 1
7* Unmapped Unmapped
A
Zones
8* Unmapped Unmapped
T
Zone 2
A
5* On Off Off On 1 2 3 4
loudspeakers (see page 22 for details).
6* Off On Off On
7* Off Off On On
1 2
1 2 3 4
3 4
INS176 15
Installation Premier 48, 88 & 168 Installation Manual
4 33 - 40 97 - 104
Remote Disable
5* 41 - 48 105 - 112
T
A
Zone 5
Zone 1
D S
6* 49 - 56 113 - 120
Power
A
T
Zones Zones
5&6
1&2 7* 57 - 64 121 - 128
T
A
Zone 6
Zone 2
8* 65 - 72 129 - 136
ON
A
T
1 2 3 4
Aux
-
Aux 12v
Aux
Aux 12v
+
12V 12V
!
-
T
A
Zone 7
Zone 3
Zones
T
Zones
3&4 7&8
T
A
Zone 8
Zone 4
5* On Off Off On 1 2 3 4
Expander Speaker Output
6* Off On Off On 1 2 3 4
The expander has an output that can be used for driving up to
7* Off Off On On one 16Ω or two 8Ω loudspeakers (see page 22 for details).
1 2 3 4
8* On Off On On 1 2 3 4
16 INS176
Premier 48, 88 & 168 Installation Manual Installation
keypad 5).
D S
Tamper Switch
A
JP2
Power LED
Zone 1
Zones
1&2 The Com Port can be used to connect a RadioPlus
Inteligent Receiver.
A
Zone 2
ON
Address Switch
T
1 2 3 4
Aux 12v
+
Aux 12V
iProx Module
-
A
iProx Layout
Zone 3
T
Off
T
JP4
Com Port On
ON
Spk
Relay 1
Terminals 1 2 3 4 Door Strike
Address Relay
+
ON
L+
Remote LED’s
the bottom of the control panel (see pages 13 & 14 for
D1
L1- L2-
details).
Remote
Prox Coil
Connections
C1 C2
Ext Coil
Network
Terminals
T
Addressing
R
INS176 17
Installation Premier 48, 88 & 168 Installation Manual
2. Connect the iD devices to the expander module, see The wiring for the system’s internal sounders (loudspeakers)
“iD Connections”. should not be connected in the same multi-core as the iD
loop.
3. Reapply power to the control panel and program the
necessary options on the panel see 60IXD
installation manual (INS261) for details.
Biscuit Connections
Each iD biscuit is identified by its own number 01 to 30 and
iD Connections contains its own internal sensor that is continuously
Each iD biscuit is connected across a two-wire detector loop. monitored by the expander module. The diagram below
Apart from observing the correct polarity, any wiring shows the connections to the biscuit for monitoring both
configuration can be used, as shown in the diagram below: tamper and alarm contacts.
60iXD LOOP +
LOOP 1
-
LOOP 2
- iD Biscuit
+ +
As LOOP 1
Tamper 01 Biscuit iD
09 10 11 12 13 14 Yellow White
08
Blue
Alarm
07
LOOP -
When the tamper switch is opened, the iD biscuit is taken
01 02 03 04 05 06
offline and a tamper condition is generated by the control
panel. If the alarm switch is opened the biscuit's internal
sensor changes state and the control panel will see this as an
* The 60iXD expander module is supplied with 4 off 10nF
active condition and will respond as appropriate.
capacitors in the spares pack. It is recommended that you
connect a 10nF capacitor approximately at the half way The diagram below shows the typical wiring of a biscuit to a
point of each iD spur. It is especially important to do this on standard PIR.
iD spurs that are less than 30 metres.
Cabling Considerations
White
Yellow
Blue
connected at the end of a single cable run using standard 4- From Expander To next detector
core alarm cable:
“iD” is a registered trade mark of Chloride Safety System Limited.
18 INS176
Premier 48, 88 & 168 Installation Manual Installation
Aux 12V
Outputs Outputs
Network and Tamper Network Address (Network 1) (Network 2) **
Terminals Output Terminals
1 Expander 1, 1 - 8 Expander 1, 1 - 8
2 Expander 2, 1 - 8 Expander 2, 1 - 8
Remote NETWORK IN Aux 12V NETWORK OUT
3* Expander 3, 1 - 8 Expander 3, 1 - 8
Engineers + - T R Tmp - - + + + - T R
2
5 ** Expander 5, 1 - 8 Expander 5, 1 - 8
Power
Bank 1 3 1 2 3 4 1 2 3 4 3
Bank 2 6 ** Expander 6, 1 - 8 Expander 6, 1 - 8
4
Outputs 4
BANK 1 BANK 2
Outputs
5 5
1 to 8 6 6
1 to 8 7 ** Expander 7, 1 - 8 Expander 7, 1 - 8
7 7
8 8 8 ** Expander 8, 1 - 8 Expander 8, 1 - 8
Tamper
Switch
Power LED
! Network 2 can only be used on the Premier 168.
* Premier 88 and 168 only
** Premier 168 only
Outputs
The output module has 16 programmable outputs, which can
be used to drive auxiliary devices such as LED’s, sounders or
relays etc. Wire as per Panel Outputs shown on page 23 (see
page 60 for details). The electrical characteristics for the
outputs are shown below:
Connecting Output Modules
Output modules are connected to the network terminals Bank Outputs Max Current Type
located at the bottom left hand corner of the control panel
(see pages 13 & 14 for details). 1 1 to 8 100mA Switched -ve
2 1 to 8 100mA Switched -ve
Output Module Addressing
Each output module must be assigned a different address Tamper Output
using the DIL switches located in the centre of the PCB.
The tamper switch on the output module is connected to the
The table below shows the expander addressing: tamper output at the top of the module. If monitoring of the lid
tamper is required, this output must be connected to a
Address DIL 1 DIL 2 DIL 3 DIL 4 suitable input on the control panel or zone expander.
1 On or off Off Off Off 1 2 3 4
5 ** On Off Off On 1 2 3 4
6 ** Off On Off On 1 2 3 4
7 ** Off Off On On 1 2 3 4
8 ** On Off On On 1 2 3 4
INS176 19
Installation Premier 48, 88 & 168 Installation Manual
Keypad Zones
Zones Zones Zones Zones Zones Zones Zones Zones
Address Network 1 Network 2 Network 3 Network 4 Network 5 Network 6 Network 7 Network 8
1 Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped
2 Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped
3 Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped
4 Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped
5 Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped
6 Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped
7 Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped
8 Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped Unmapped
Expander/OP16 Outputs
Outputs Outputs Outputs Outputs Outputs Outputs Outputs Outputs
Address Network 1 Network 2 Network 3 Network 4 Network 5 Network 6 Network 7 Network 8
1 Exp. 1, 1-8 Exp. 1, 1-8 Exp. 1, 1-8 Exp. 1, 1-8 Exp. 1, 1-8 Exp. 1, 1-8 Exp. 1, 1-8 Exp. 1, 1-8
2 Exp. 2, 1-8 Exp. 2, 1-8 Exp. 2, 1-8 Exp. 2, 1-8 Exp. 2, 1-8 Exp. 2, 1-8 Exp. 2, 1-8 Exp. 2, 1-8
3 Exp. 3, 1-8 Exp. 3, 1-8 Exp. 3, 1-8 Exp. 3, 1-8 Exp. 3, 1-8 Exp. 3, 1-8 Exp. 3, 1-8 Exp. 3, 1-8
4 Exp. 4, 1-8 Exp. 4, 1-8 Exp. 4, 1-8 Exp. 4, 1-8 Exp. 4, 1-8 Exp. 4, 1-8 Exp. 4, 1-8 Exp. 4, 1-8
5 Exp. 5, 1-8 Exp. 5, 1-8 Exp. 5, 1-8 Exp. 5, 1-8 Exp. 5, 1-8 Exp. 5, 1-8 Exp. 5, 1-8 Exp. 5, 1-8
6 Exp. 6, 1-8 Exp. 6, 1-8 Exp. 6, 1-8 Exp. 6, 1-8 Exp. 6, 1-8 Exp. 6, 1-8 Exp. 6, 1-8 Exp. 6, 1-8
7 Exp. 7, 1-8 Exp. 7, 1-8 Exp. 7, 1-8 Exp. 7, 1-8 Exp. 7, 1-8 Exp. 7, 1-8 Exp. 7, 1-8 Exp. 7, 1-8
8 Exp. 8, 1-8 Exp. 8, 1-8 Exp. 8, 1-8 Exp. 8, 1-8 Exp. 8, 1-8 Exp. 8, 1-8 Exp. 8, 1-8 Exp. 8, 1-8
20 INS176
Premier 48, 88 & 168 Installation Manual Installation
4k7W
Alarm
Fault contact resistor = 2K2
A T A T
Zone 1 Zone 1
2k2W
Fault Tamper
4k7W
E.O.L
1 Normally Closed Device
with Fault and Mask
(Mask = Fault + Alarm)
4k7W
1 Normally
E.O.L
Closed Device
2k2W
A T A T
Zone 1 Zone 1
A T A T
Zone 1 Zone 1
INS176 21
Installation Premier 48, 88 & 168 Installation Manual
22 INS176
Premier 48, 88 & 168 Installation Manual Installation
3 3
Channel Inputs
Programmed 4 4 Digicom
as Positive 5 5 Outputs
Removed 6 6
7 7
8 8
INS176 23
Installation Premier 48, 88 & 168 Installation Manual
Remote LED
Control (Optional)
Panel
+V In +V In
1k EOL
OV OV OV
To enable 2-Wire smoke detection on panel output 1, a jumper link must be fitted across the bottom two pins of JP10. The Area
Option ‘2-Wire Smoke’ also needs to be enabled (see page 45).
Aux
Input
When the Auxiliary Input is programmed as ‘PSU Monitor’ the system will respond as follows:
24 INS176
Premier 48, 88 & 168 Installation Manual Installation
T1
R1
RJ45
Lead
Box ComISDN
Tamp
N/O COM N/C
OP5
OP4+
! For details on testing the communicators, see page 67.
OP3+
OP2-
OP1-
-
Spk
INS176 25
Installation Premier 48, 88 & 168 Installation Manual
• Connect the Molex connector of the RPD-Com lead to • Connect the Molex connector of the GSM-Com lead to
Com2 on the control panel Com2 on the control panel
• Connect the 25-Way D-Type connector of the RPD-Com • Connect the RJ45 connector of the GSM-Com to the
to the Radio-Pad GSM Module
• Locate the power lead connector into the socket at the • Locate the power Jack Plug into the socket at the bottom
bottom of the Radio-Pad of the GSM Module
• Connect the Black lead to the DC- terminal on the control • Insert a SIM card into the bottom of the GSM Module
panel
• Connect power to the control panel
• Connect the lead with the White stripe to the DC+
terminal on the control panel Programming the GSM Module
• Follow the procedure for Registering the Radio-Pad • Program Com 2 for GSM Module operation (see page 77
for details)
Registering the Radio-Pad • Refer to the GSM Module installation guide for full
Whenever a Paknet Radio-Pad is installed or moved, it must programming details.
be registered onto the network. To do this:
• Press and hold the test button on the front of the Paknet AV Module
Radio-Pad
Before connecting the AV Module, isolate ALL power from the
• With the test button still pressed, connect power to the control panel (AC mains and battery), do not continue if there
control panel and wait for the yellow service light on the is still power present on the control panel.
Radio-Pad to flash
To install the AV Module onto the control panel:
• Release the test button
• Connect one end of the patch lead on to the Expansion
Within 2 minutes the yellow service light should stop flashing
Port of the AV Module
and remain steady. This means that the Paknet Radio-Pad
has now selected and locked on to the Base Station with the • Connect one other end of the patch lead on to the
strongest signal. Expansion Port of the control panel
The Paknet Radio-Pad should be re-registered on every site
visit, this is to ensure that any new Vodafone Packet Radio Programming the AV Module
Service Base Stations in the vicinity are recorded by the • Program the Expansion Port for AV Module operation
Paknet Radio-Pad. (see page 77 for details)
• Refer to the AV Module installation guide for full
Programming the Radio-Pad programming details.
• Program Com 2 for Radio-Pad operation (see page 77
for details)
ComIP Module
• Refer to the Radio-Pad installation guide for full
programming details. Before connecting the ComIP Module, isolate ALL power from
the control panel (AC mains and battery), do not continue if
there is still power present on the control panel.
To install the ComIP onto the control panel:
26 INS176
Premier 48, 88 & 168 Installation Manual Installation
F2
Load
Defaults
Com 2 C om 1
JP6
JP2
Network 1
Network 2
1Amp
1Amp
PC-Com
F4
PRINT-Com
The PRINT-Com has two connectors. The 25-way D-type
connector connects to a Serial Printer and the Molex
connector plugs onto Com 1 on the control panel. Connecting a Printer
The Premier 48, 88 and 168 all support printer facilities. The
printer is connected to the Com 1 connector located on the
control panel and can be used to print the control panel event
log.
In order for the printer to work correctly, ensure that it is set to
the following:
RPD-Com • Baud Rate = 4800
The RPD-Com has two connectors. The 25-way D-type • Parity = None
connector connects to a Paknet Radio-Pad and the Molex • Start Bits =1
connector plugs onto Com 2 on the control panel. • Stop Bits =2
• Data Bits =8
• DTR = Normal
• Columns = 40 or 80 (see page 50)
GSM-Com
The GSM-Com has two connectors. The RJ45 connector connects
to a GSM Module, the Molex connector plugs onto Com 2 on the PRINT-Com
RS232 Data
control panel.
Connect to
COM1
INS176 27
Commissioning and Troubleshooting Premier 48, 88 & 168 Installation Manual
• Connect the black battery lead to the negative (–) • Check that the battery wires are connected correctly; red
terminal of the standby battery and the red battery lead from BATT+ to the battery positive (+), black from
to the positive (+) terminal of the standby battery BATT- to the battery negative (-)
• Press and hold the Factory Default button Heartbeat LED is not flashing
• Press the battery kick-start button to connect the battery • Remove ALL power (AC Mains and Battery) and then
and ensure that the green heartbeat light illuminates reapply power again
• After the heartbeat light has illuminated, let go of the Network Data LED’s are not flashing
Factory Default button (the heartbeat light will continue • Remove ALL power (AC Mains and Battery) and remove
to flash whilst the factory default settings are being ALL wires from the network terminals. Then
loaded, this can take up to 30 seconds) re-apply power again before referring to the Network
• If the system goes into alarm, enter the default Diagnostics table on page 13
Engineer code #$%" , and the alarm
tone will stop Keypads
• To access the Engineer Programming Menu, enter the Keypad does not operate
default Engineer code #$%" • Check that the keypad is wired correctly from the control
• Program the system as described in section 5 panel (see page 13 for wiring details)
(Programming the Control Panel) • Check the network fuses F3 and F5 and replace if blown
• Perform a zone test as described on 92. Remember that • Use the network diagnostics (see page 13 for details)
some powered detectors (e.g. PIR’s and combined
technology detectors) take several minutes to warm up Keypad does not accept codes
and become operational • If the system has more than one keypad check that each
• Test the internal sounder, external sounder and strobe as keypad is addressed differently, see page 15 for details
described on page 93 • If the keypad is on a long cable run, check the voltage
• Replace the lid and secure with the lid screw supplied between the ‘+’ and ‘–’ terminals at the keypad and
ensure that it measures no less than 10.0V
• Press ' followed by YES to leave the programming
menu, the system will return to normal • Check that you are using the correct User codes. The
default Engineer code is #$%" and the
• The display will be showing that there is a ‘Mains Power
default Master User code is ()*+,
Off’ condition. Switch on the AC mains supply to the
control panel • Check that the User code you are using is not ‘Time
Locked’, if the User code is time locked then the access
• The normal banner message (if programmed) will now
code will only be accepted when Control Timer 1 is off
be displayed
(see pages 52 and 88 for details)
Installation is now complete and the system is Keypad zones do not operate
ready for use. • Each keypad zone has to be mapped onto the system
before it can be used (see page 57 for details)
• The zone is not programmed (see page 34 for details)
Keypad emergency keys do not operate
• Each keypad can be configured so that the emergency
keys PA, FIRE and MEDICAL can be enabled or
disabled. Check that the keypad has been programmed
correctly (see page 57 for details)
28 INS176
Premier 48, 88 & 168 Installation Manual Commissioning and Troubleshooting
Expander Operation
Expander does not operate at all The system will not allow me to arm
• Check that the expander is wired correctly from the • Check that there are no outstanding problems (see page
control panel (see page 13 for wiring details) 30 for details)
• Check the network fuses F3 and F5 and replace if blown • Check that there are no outstanding alarms that require
resetting
System does not recognise zones
• Check that the User code has been programmed to
• If the expander is on a long cable run, check the voltage allow arming (see page 87 for details)
between the + and – terminals at the expander and
ensure that it measures no less than 10.0V • Check that the User code has been assigned to the
correct areas (see page 85 for details)
The speaker output does not work
• If a ‘Local’ User code is being used (see page 87 for
• The expander can be configured so that Alarm, Entry, details) ensure that the keypad being used is assigned
Exit, Chime tones etc. can be enabled or disabled. to the correct area (see page 56 for details)
Check that the expander has been programmed
correctly (see page 59 for details) The system will not allow me to disarm
• The speaker volume on the expander is electronically • Check that the User code has been programmed to
adjustable. Check the volume is set to the desired level allow disarming (see page 87 for details)
(see page 59 for details) • Check that the User code has been assigned to the
correct area(s) (see page 85 for details)
Zones • If a ‘Local’ User code is being used (see page 87 for
One or more zones show an alarm details) ensure that the keypad being used is assigned
to the correct area (see page 56 for details)
• Check that the zone is wired correctly (see page 21 for
wiring details)
Communicator
The Communicator will not dial
• By default the communicator is disabled, check that the
communicator is enabled (see page 71 for details)
• Check that the telephone line has been correctly wired to
the communicator (see page 25 for wiring details)
• Check that the telephone numbers are programmed
correctly (see page 70 for details)
• Check that the account numbers are programmed
correctly (see page 70 for details)
• Check that the dial attempts are not programmed as zero
(see page 70 for details)
• Check that the reporting areas have been programmed
correctly (see page 70 for details)
• Check that the reporting options have been programmed
correctly (see page 70 for details)
Communicator dials but does not communicate
• Check that the telephone numbers are programmed
correctly (see page 70 for details)
• Check that the correct protocol is programmed (see
page 70 for details)
INS176 29
Factory Defaults Premier 48, 88 & 168 Installation Manual
When the system requires attention because of a potential There is a fault with the ATS (Alarm
."3!I(:K!2(#-:
problem, the display will show one of three service !"#$!%&!'()!*%%+ Transmission System).
messages. These messages can also be accessed at any
time, allowing the user to view installer information. L0!I(:K!.4(5-(E-$ There are no ATS (Alarm Transmission
!"#$!%&!'()!*%%+ System) paths available.
! These messages would normally be programmed with
the telephone numbers of the installer or the Alarm !M!LH!N.""7;>!M The Standby Battery has not been
!"#$!%&!'()!*%%+ connected,
Receiving Centre (see page 53 for details).
There is a fault with the control panel
To display the service messages, proceed as follows: N(::$)=!2(#-:
!"#$!%&!'()!*%%+ standby battery or it is not connected.
The display will normally show the time and date:
.)$(!2(5-$D!"$<: Zones that have been placed on test
!!!! !"#$!%&!'()!*%%+ have failed the test.
!"#$!%&!'()!*%%+
I(8$-!?5D!"(/O$) There is a fault with the control panel lid
Press ! followed by # for the Service message: !"#$!%&!'()!*%%+ tamper.
Press ! followed by $ for the Reset message: .#P5-5()=!"(/O$) There is a fault with the auxiliary tamper
!"#$!%&!'()!*%%+ on the control panel.
,(--!78958$$)!:0
!!;$<$:!3=<:$/ N$--!2#<$!N-0J8 The bell fuse on the control panel has
!"#$!%&!'()!*%%+ blown.
Press ! followed by % for the Anti-code message:
.#P1!2#<$!N-0J8 The Auxiliary fuse on the control panel
,(--!.;,!:0 !"#$!%&!'()!*%%+ has blown.
;$<$:!3=<:$/
;QI!RSR!"(/O$) There is a fault with the lid tamper of
Press - to exit from the message, the display will then !"#$!%&!'()!*%%+ Keypad X,X.
return to normal.
;QI!RSR!?0<: Keypad X,X has been lost off of the
When alarm information is being displayed, pressing the !"#$!%&!'()!*%%+ system.
SCROLL key will slow down the display and also allow
7RI!RSR!"(/O$) There is a fault with the lid tamper of
manual scrolling through the events. !"#$!%&!'()!*%%+ Expander X,X
Fault Warning Tones 7RI!RSR!?0<: Expander X,X has been lost off of the
When a fault condition occurs i.e. mains fail, line fault etc. the
!"#$!%&!'()!*%%+ system.
internal sounders will chime every 30 seconds for 3 minutes. The voltage at expander X,X is very low.
7RI!RSR!?0!T0-:<
The chiming will automatically stop when a valid User code is !"#$!%&!'()!*%%+
entered, when - is pressed or after 3 minutes (whichever
occurs first). The fault indication will only be cleared from the 7RI!N$--!"(/O!RR The expander’s Auxiliary input (that is
display when the fault has been rectified i.e. power, !"#$!%&!'()!*%%+ programmed as bell tamper) is in fault.
telephone line has been restored.
7RI!.#P!"(/O!RR The expander’s Auxiliary input (that is
Fault Messages !"#$!%&!'()!*%%+ programmed as aux tamper) is in fault.
!3>3"7'!.?7;"3@ There are system faults waiting to be 3$)456$!;$U#5)$D The service timer has expired indicating
!"#$!%&!'()!*%%A viewed, enter a valid user code to view !"#$!%&!'()!*%%+ that the system requires a service (the
the faults. After entering a code faults will system can normally still be used).
be displayed for 30 seconds. If the fault is
not reset within 30 seconds, this 30))=S!,0D$!80: The user code is locked out (normally
message will be displayed again. (--0J$D!#<$!".V during entry). The system must be
disarmed using a Prox TAG.
,08B5)/!C$456$< The number of devices connected to the
!"#$!%&!'()!*%%+ networks has changed from the last time ;$/0:$!Q$=O(D!5< To many invalid code attempts have
a ‘Confirm Devices’ was done. 80J!?H,Q7C!0#: caused the keypad to lock out. The
keypad will remain like this for 5 minutes.
>0#!8$$D!(!#<$) Engineer access is programmed for
:0!$8(E-$!(66$<< Engineer code + User code (see page M!.)$(!3$6#)$D!M The keypad has been disabled to prevent
49 for details). !"#$!%&!'()!*%%+ unauthorised access. The display will
automatically clear when it is re-enabled.
>0#!8$$D!(!#<$) The Engineers code was entered when the
:0!#8()/!<=<:$/ system was fully armed (access to the "5/$!.)/589!W Areas are being armed using one of the
programming menu can only be gained !!!!.1111111 control timers (enter a valid User code to
when the system is not fully armed. defer the arming for 30 minutes).
30 INS176
Premier 48, 88 & 168 Installation Manual The Programming Menu
Part
C0!=0#!J(8:!:0
.-:$)!I():!.)/<`
A menu option can then be selected by pressing one of the
keys shown or by using the & key to search. Once Menu
C0!=0#!J(8:
.)/589!'$8#!`
selected, press YES to access that option.
Menu
C0!=0#!J(8:
To leave the selected menu option and return to the main \<$)!'$8#!`
programming menu, press -.
0_ >73!:0!3$-$6:Z[ Yes
?09!0BB!7LV_L77;
To exit from the Main Programming menu but still remain
‘Logged’ onto the system (zones and tampers still disabled), !.-()/!78958$$)
Reset
press - and the display will show ‘Alarm Engineer F0)G589!H8!35:$1
Working On Site’.
Out of Programming Menu
To log the Engineer off the system, press ' followed by (Engineer Still Logged On)
YES and the system will revert to its normal condition.
The table below shows the menu options available:
INS176 31
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
+, Setup Users 0 User Code - Exit programming menu (engineer still logged on)#
, 0 User Areas ' Log Off Engineer
, 0 User Type
, (not always available) 0 User Options
, (not always available) 0 User Config.
, 0 User Time Lock
, 0 User Text
, (not always available) 0 Door Control
, 0 Add TAG
32 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
+, T U V 8 t u V
., W X Y Z 9 w x y z
Press 0 to return to normal, the display will look
something like this:
&, Move Cursor !!!!
!"#$!%&!'()!*%%+
-, Backspace (delete)
2, Copy Text The Engineer is now logged out of the Programming menu.
/, Paste Text
1, Predictive Text
3, Upper/Lowercase, Predictive text and Clear Screen
! The Engineer will be automatically logged out when the
Engineer Logoff Delay Timer Expires (See Page 48)
The control panel also features Predictive text. This can be Resetting the Engineers Code (User 00)
used to make inserting words easier, i.e. when spelling the
If the Engineer code (User 00) has been lost or forgotten, it
word PIR, instead of typing 7444777, all that you need to do
is type 747 and the word is automatically selected. can normally be reset back to the factory default of
#$%" . However, this can only be done if the
! This feature can be turned on and off as required by
pressing the 1 key and can also be automatically
NVM has not been locked (see page 49 for details).
To Reset the Engineer code (User 00):
selected every time text mode is entered (see page 50
for details).
ENSURE THAT THE LID TAMPER IS CLOSED
Copying and Pasting Hold down the ‘Factory Default’ button for 6 seconds (with
the control panel still powered), after 6 seconds, the
When programming any items i.e. Zones, Timers, Options sounders/keypads will bleep to indicate that the Engineer
etc. pressing CHIME at any point will ‘Copy’ the information code has been reset.
that has just been programmed into memory. To program
another item using the information in memory, select the item
and press PART to ‘Paste’ the information.
! NO other codes/programming will be affected, it is just
the User 00 Engineer code that will be reset.
INS176 33
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
Yes
Zone 004 N1,E1,4 No Zone 004 N1,E1,4 3 def Zone 004 N1,E1,4
Entry/Exit 1 Entry/Exit 1 < Guard <
Yes
Reset
Press NO to Use keys 1 - 8 to select Press NO to
edit the zone an attribute or use the select/deselect
Yes
attributes 1 SCROLL key to search the attribute
Yes
Reset
Yes Press NO to Use keys 1 - 8 to select Press NO to
edit the zone an attribute or use the select/deselect
attributes 2 SCROLL key to search the attribute
Yes
Zone 004 Areas: No Zone 004 Areas: 2 abc Zone 004 Areas:
A....... > A******* < > AB****** <
Yes
Reset
Use keys 0 - 9 to program
Yes Press NO to text the same way that a
edit the mobile phone works
zone text e.g. 7, 444, 777 = PIR
Yes
Reset
Press NO
Yes to Change the
Chime type
Zone 004 Chime: No Zone 004 Chime: No Zone 004 Chime: No Zone 004 Chime:
Silent Chime 1
^ Chime 2
^ Chime 3
^
Reset
Yes
Yes Yes
Reset
Zone 004 Wiring: No Zone 004 Wiring: Zone 004 Wiring: Zone 004 Wiring:
Double Pole/EOL Double Pole/EOL< 1K/1K/(3K) < 4K7/6K8/(12K) <
Yes Yes Yes
Yes
34 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
7 - PA Audible
Zone Types Normally used for monitoring Panic or hold-up alarms. This
Each zone must be programmed before it is recognised by zone type will cause a Panic alarm if it is activated when the
the system. system/area is armed or disarmed.
Zone numbers are entered as a three digit number i.e. Zone 1 8 - PA Silent
would be entered as 001. Each zone consists of a zone type, Normally used for monitoring Panic or hold-up alarms. This
attributes, areas and zone text. zone type will cause a silent Panic alarm if it is activated when
the system/area is armed or disarmed.
When programming zones, first select a zone type then select
any required attributes, assign the zone to an area and then 9 - Fire
program any required zone text. Normally used for monitoring smoke detectors. This zone
type will cause a Fire alarm with distinctive fire tone if it is
Zone Type + Zone Attributes + Zone Areas + Zone Text = activated when the system/area is armed or disarmed. In
Zone Programmed. addition, the bell output will pulse.
The following zone types are available: 10 - Medical
0 - Not used This zone type will cause a Silent alarm if it is activated when
A zone that is not monitored by the system, unused zones the system/area is armed or disarmed. The panel will also
should be programmed as ‘Not Used’ or linked out. report a Medical alarm to the Alarm Receiving Centre when
using ‘Contact ID’ reporting.
1 - Entry/Exit 1
Normally used for the main entry/exit door i.e. Front Door. The 11 - 24Hr Gas
zone can be activated during the exit mode without causing a This zone type will cause an Audible alarm if it is activated
‘Fault’. Once the system/area is armed, activation of the zone when the system/area is armed or disarmed. The panel will
will start the ‘Entry 1 Delay’ timer for the selected area. also report a 24-Hour Gas alarm to the Alarm Receiving
Centre when using ‘Contact ID’ reporting.
2 - Entry/Exit 2
Normally used for another entry/exit door that requires a 12 - Auxiliary
different entry delay i.e. Back Door, Garage Door etc. The This zone type will cause a Silent alarm if it is activated when
zone can be activated during the exit mode without causing a the system/area is armed or disarmed. The panel will also
‘Fault’. Once the system/area is armed, activation of the zone report an Auxiliary alarm to the Alarm Receiving Centre when
will start the ‘Entry 2 Delay’ timer for the selected area. using ‘Contact ID’ reporting.
13 - Tamper
! If any Entry/Exit zone remains active at the end of the entry time, it will
automatically be omitted until the system has been unset and re-set.
This zone type will cause an Internal alarm if it is activated
when the system/area is disarmed and will cause an Intruder
If an Entry/Exit zone type is locked out, ‘Guard Access’ zones in the alarm when the system/area is armed.
same area as the omitted Entry/Exit zone will automatically become
‘Entry/Exit 1’ zones to allow access into the premises without causing 14 - Exit Terminator
an alarm. This zone type is used to finalise the arming procedure when
If an ‘Entry/Exit 1 or 2’ zone type is assigned the ‘Entry/Exit 2’ attribute (see
arming the system/area (see page 40 for details).
page 36), when a zone with the ‘Guard’ attribute activates and causes an
alarm (when the area is fully armed), the zone will become a ‘Guard’ zone
15 - Moment Key
for the duration of the ‘Abort’ timer. This zone type can be used to arm and disarm one or more
areas. When the zone is activated and then secured the areas
3 - Guard assigned to the zone will arm. When the zone is subsequently
Normally used for detection devices such as PIR’s, Door activated and then secured the system will disarm the areas
Contacts etc. This zone type will cause an Intruder alarm if it is assigned to the zone. Tamper faults will not arm or disarm
activated when the system/area is armed. This zone type will anything, but will cause a Tamper alarm.
also activate any output programmed as ‘Guard Alarm’.
16 - Latch Key
4 - Guard Access This zone type can be used to arm and disarm one or more
Normally used for detection devices along the entry/exit route. areas. When the zone is activated, the areas assigned to the
This zone type will allow the user to walk past the detector zone will arm. When the zone is secured, areas assigned to
without causing a ‘Fault’ during the exit mode or an Intruder the zone will disarm. Tamper faults will not arm or disarm
alarm during the entry mode, however, the zone will cause an anything, but will cause a Tamper alarm.
immediate Intruder alarm if activated at any other time. This
zone type will also start the entry mode when the system/area 17 - Security
is part armed and activate any output programmed as ‘Guard This zone type can be used to Lockout keypads. When the
Access Alarm’. zone is activated, keypads assigned to the same area will not
accept any key presses. When the zone is secured, all
5 - 24Hr Audible keypads respond as normal.
This zone type will cause an internal alarm if it is activated
when the system/area is disarmed and will cause an Intruder 18 - Omit Key
alarm when the system/area is armed. The panel will also This zone type will isolate any zone assigned to the same
report a ‘24-Hour’ alarm to the Alarm Receiving Centre when area as long as it has the ‘Omit’ attribute.
using ‘Contact ID’ reporting.
19 - Custom
6 - 24Hr Silent This zone type can be programmed to operate as required
This zone type will cause a silent alarm if it is activated when using its own set of attributes (see page 37 for details).
the system/area is disarmed and will cause an Intruder alarm
when the system/area is armed. The panel will also report a
‘24-Hour’ Alarm to the Alarm Receiving Centre when using
‘Contact ID’ reporting.
INS176 35
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
Zones without this attribute will respond as normal. Zones without this attribute will not cause an Intruder alarm
when activated if the engineer arms the system/area.
36 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
A key switch zone type with this attribute will log when the
zone is activated and also when the zone is restored. Zone Chime
Each zone can be programmed to chime the internal sounders
Attributes for Custom Zones using one of the available chime tones when activated.
INS176 37
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
38 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
INS176 39
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
.)$(!I)09)(//589 .)$(!I)09)(//589
Yes Yes
.)$(!I)09)(//589 .)$(!I)09)(//589
"5/$)< "5/$)<
1_ 2 abc
.)$(!I)09)(//589 .)$(!I)09)(//589
.)/589!'0D$< .)$(!.)/!3#5:$<
Yes Yes
.)$(!.!.)/!E=Z .)$(!.)/!3#5:$!+
!!!"5/$D!$P5: !!!!.1111111
Use keys 1 - 8 to select an
Use the SCROLL key Area Arm Suite or use the
4 ghi
to select an area SCROLL key to search e.g. 4
40 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
.)$(!I)09)(//589 .)$(!I)09)(//589
Yes Yes
.)$(!I)09)(//589 .)$(!I)09)(//589
"5/$)< "5/$)<
3 def 4 ghi
.)$(!I)09)(//589 .)$(!I)09)(//589
.)$(!3#5:$!"$P: 3#5:$!.)/!'0D$<
Yes Yes
3\_"7!+ 3#5:$!+!.)/!E=Z
.)$(!.)/!3#5:$!+ !!!"5/$D!$P5:
Use keys 1 - 8 to select
an Area Arm Suite or use the Use the SCROLL key
4 ghi
SCROLL key to search e.g. 4 to select a suite
3\_"7!d 3#5:$!*!.)/!E=Z
.)$(!.)/!3#5:$!d !!!"5/$D!$P5:
Use keys 1 - 5 to select
Press NO to edit the
No 1 an arming mode
Area Arm Suite text
e.g. 1 = Entry/Exit
3\_"7!+ 3#5:$!*!.)/!E=Z
f7D5:!"$P:!!W.N, !W!78:)=]7P5:
Use keys 0 - 9 to program
???? text the same way that a Yes
mobile phone works
N$D:5/$!3$::589
!7D5:!"$P:!!W.f,
The way that an Area Arm Suite arms when selected, can be
Yes configured for any of the following options:
1 - Entry/Exit
Text may be assigned to the Area Arm Suites to allow the user The suite will arm after the ‘Entry/Exit’ door has been closed
to select the suites by description instead of number. Up to 16 and the ‘Exit Settle’ timer has expired.
characters of text can be programmed for each suite. 2 - Exit Term.
Example The suite will arm after the ‘Entry/Exit’ door has been closed,
Text descriptions for the Area Arm Suites could be useful the ‘Exit Terminator’ button has been pressed and the ‘Exit
where more than one suite has been defined. The user Settle’ timer has expired.
wishes to arm areas A and B at night but is not too sure 3 - Timed Exit (Default for All Areas)
which suite to select. The suite will arm after the programmed ‘Exit Time’ has
• Areas ‘A and B’ would be assigned to ‘Area Arm Suite 1’ expired.
•
(see page 40 for details)
When the user wants to arm the system at night, ‘Area
! If an ‘Exit Terminator’ zone is activated at any point
during the exit mode, any remaining exit time is
Arm Suite 1’ would be selected cancelled and the area will arm immediately.
• Text will be displayed to confirm that the selected suite is 4 - Instant
correct i.e. ‘Bedtime Setting’ The suite will arm instantly.
• Areas A and B are automatically selected for armed 5 - Deferred
Text is programmed in a similar way to mobile phones. Select The suite will arm after the programmed ‘Exit Time’ has
characters by pressing the corresponding key the expired. However, if any zones not on the exit route are
appropriate number of times (to select a character on the activated during the exit mode, the ‘Exit Time’ is restarted.
same key, press & to move the cursor along).
INS176 41
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
7 - Bell Tamper
Area Options Areas assigned to ‘Bell Tamper’ will cause a Tamper alarm
when the Bell tamper loop is broken.
>73!:0!3$-$6:Z[ Areas not assigned to ‘Bell Tamper’ will never cause a
.)$(!I)09)(//589
Tamper alarm when the bell tamper loop is broken.
Yes
8 - Auxiliary Tamper
.)$(!I)09)(//589 Areas assigned to ‘Auxiliary Tamper’ will cause a Tamper
"5/$)< alarm when the Auxiliary tamper loop is broken.
5 jkl Areas not assigned to ‘Auxiliary Tamper’ will never cause a
Tamper alarm when the auxiliary tamper loop is broken.
.)$(!I)09)(//589
.)$(!HO:508< 9 - Panel Speaker
Yes Areas assigned to ‘Panel Speaker’ will cause the control
panel speaker to activate when those areas are in alarm,
.#:0!I():!.)/ entry and exit etc.
!!!!.1111111!!
Use the SCROLL Areas not assigned to ‘Panel Speaker’ will never cause the
key to select an control panel speaker to activate when those areas are in
area option
alarm, entry and exit etc.
;$/0:$!.)/
!!!!.1111111!! 10 - Bell & Strobe op
No
Press NO to change Areas assigned to ‘Bell & Strobe op’ will cause the
the area option
‘Bell/Strobe’ output on the control panel to activate when an
;$/0:$!.)/ alarm occurs in those areas.
!!W!.MMMMMMM!e
Use keys 1 - 8 Areas not assigned to ‘Bell & Strobe op’ will never cause the
4 ghi to select an area ‘Bell/Strobe’ output on the control panel to activate when an
e.g. 4 = D
alarm occurs in those areas.
;$/0:$!.)/
!!W!.MMCMMMM!e 11 - Alarms Eng Reset
Yes Each area can be programmed for Engineer or User reset
following an Intruder alarm. Areas Assigned to ‘Alarms Eng
Reset’ will respond as follows:
These options control how various features affect each area.
• The assigned areas can only be reset using an Engineer
Any number of areas can be assigned to each option.
code
1 - Auto Part Arm If ‘Anti-code Reset’ is enabled (option 14) the assigned
Areas assigned to ‘Auto Part Arm’ will fully arm if an areas can also be reset using the Anti-code
‘Entry/Exit’ zone is activated during the exit mode and will
‘Part Arm 1’ if an ‘Entry/Exit’ zone is not activated during the Areas not assigned to ‘Alarms Eng Reset’ can be reset with
exit mode. any User code that is valid for those areas.
Areas not assigned to ‘Auto Part’ will always fully arm. 12 - Confirmed Reset
Each area can be programmed for Engineer or User reset
2 - Part Arm Instant
following a Confirmed alarm. Areas Assigned to ‘Confirmed
Areas assigned to ‘Part Arm Instant’ will arm instantly when
Reset’ will respond as follows:
part arming.
Areas not assigned to ‘Part Arm Instant’ will use the area exit • The assigned areas can only be reset using an Engineer
timer when part arming. code
If ‘Anti-code Reset’ is enabled (option 14) the assigned
3 - Part Arm Silent areas can also be reset using the Anti-code
Areas assigned to ‘Part Arm Silent’ will never generate Exit
tones when part arming. Areas not assigned to ‘Confirmed Reset’ can only be reset
Areas not assigned to ‘Part Arm Silent’ will always generate with any User code that is valid for those areas providing that
Exit tones when part arming. ‘Alarms Eng Reset’ (option 14) is also programmed for user
reset.
4 - Remote Arm
Areas assigned to ‘Remote Arm’ can be armed remotely 13 - Tamper Eng Reset
using the Wintex UDL software and a PC. Each area can be programmed for Engineer or User reset
following a Tamper alarm (when the area is unarmed). Areas
Areas not assigned cannot be armed remotely. assigned to ‘Tamper Eng Reset’ will respond as follows:
5 - Remote Disarm • The assigned areas can only be reset using an Engineer
Areas assigned to ‘Remote Disarm’ can be disarmed code
remotely using the Wintex UDL software and a PC.
• If ‘Anti-code Reset’ is enabled (option 14) the assigned
Areas not assigned to ‘Remote Arming’ cannot be disarmed areas can also be reset using the Anti-code
remotely.
Areas not assigned to ‘Tamper Eng Reset’ can be reset with
6 - Panel Tamper any User code that is valid for those areas.
Areas assigned to ‘Panel Tamper’ will cause a Tamper alarm
when the control panel cover is removed.
Areas not assigned to ‘Panel Tamper’ will never cause a
Tamper alarm when the control panel cover is removed.
42 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
INS176 43
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
44 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
34 - Armed = Coms
When Areas are assigned to ‘Armed = Coms’ the system will
Time Arm Area
respond as follows:
• Communications and outputs (Alarm, Confirmed etc.) for >73!:0!3$-$6:Z[
.)$(!I)09)(//589
ALL areas will only operate when all of the assigned areas
Yes
are armed.
When No Areas are assigned to ‘Armed = Coms’ the system .)$(!I)09)(//589
will respond as follows: "5/$)<
INS176 45
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
Area Text
>73!:0!3$-$6:Z[
.)$(!I)09)(//589
Yes
.)$(!I)09)(//589
"5/$)<
7 pqrs
.)$(!I)09)(//589
.)$(!"$P:
Yes
!
"$P:!B0)!.)$(!.
Use keys 1 - 8 to select
4 ghi an Area or use the
SCROLL key to search e.g. 4
!
"$P:!B0)!.)$(!C
Press NO to edit
No
the Area text
!
f7D5:!"$P:!!W.N,
Use keys 0 - 9 to program
???? text the same way that a
mobile phone works
;$6$O:508
!7D5:!"$Pf!!W.N,
Yes
46 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
26 - Keypad PA Delay
When keypad ‘option 6’ is programmed as ‘PA Delayed’ (see
System Config.
page 57 for details), and a keypad PA alarm (1 & 3) is
activated, this timer starts. If a User code is entered before >73!:0!3$-$6:Z[
this timer expires, no PA alarm will occur. However, if a User V-0E(-!HO:508<
code is not entered before this timer expires, a PA alarm will Yes
occur.
V-0E(-!HO:508<
27 - Confirmation Dly 3=<:$/!"5/$)<
When an Intruder alarm occurs, this timer starts. If a second
1
(different) zone is activated within this time window, the
‘Confirmed’ output will activate. When this timer V-0E(-!HO:508<
expires, the ‘Confirmed’ output will no longer activate. 3=<:$/!,08B591
48 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
INS176 49
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
50 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
Panel Grade 2
All options relating to PD6662: 2004/EN 50131-1 Grade 3 that
System Options
are not required for Grade 2 are disabled automatically. Also, the
Premier Anti-code reset becomes the standard 4 digit number >73!:0!3$-$6:Z[
and all user and engineer codes can be 4, 5 or 6 digits. V-0E(-!HO:508<
Yes
38 - Disable FOB PA
When a ‘RadioPlus’ Transmitter FOB is being used with the
V-0E(-!HO:508<
alarm system, the Panic Alarm (PA) function i.e. Pressing 3=<:$/!"5/$)<
buttons 1 and 2 together, is disabled.
2 abc
Enable RF FOB PA
When a ‘RadioPlus’ Transmitter FOB is being used with the V-0E(-!HO:508<
3=<:$/!HO:508<
alarm system, the Panic Alarm (PA) function i.e. Pressing
buttons 1 and 2 together, is enabled. Yes
,K5/$!T0-#/$
!!!!?$4$-!hW*
Enter a value or use the
SCROLL key to increase
7 pqrs
or decrease the value
e.g. 8 = Full Volume
,K5/$!T0-#/$
!!!!?$4$-!h!X
Yes
INS176 51
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
V-0E(-!HO:508< V-0E(-!HO:508<
Yes Yes
V-0E(-!HO:508< V-0E(-!HO:508<
3=<:$/!"5/$)< 3=<:$/!"5/$)<
3 def 4 ghi
V-0E(-!HO:508< V-0E(-!HO:508<
'085:0)!i()DJ()$ ,08:)0-!"5/$)<
Yes Yes
'085:0)!i()DJ()$ ,08:)0-!"5/$)!+(
!.!.!2!N!.!?!M 5<!H8!(:!W+aZ%%
Press NO to edit Use the SCROLL key to
No
the options select control timer 1 - 8
."3!I(:K!2(#-:< ,08:)0-!"5/$)!*(
W.!.!2!N!.!?!M 5<!H8!(:!W+aZ%%
Use keys 1 - 8 to select
Enter the ‘a’ On time
an attribute or use the ????
for e.g. 1152 = 11:52 am
SCROLL key to search
N$--!"(/O$) ,08:)0-!"5/$)!*(
!I!.!2WN!.!?!M 5<!H8!(:!W++ZA*
Press NO to Press YES to select
No select/deselect Yes the ‘a’ On Time
the option ‘DAYS OF OPERATION’
N$--!"(/O$) "5/$)!*(!H8!C(=<
!I!.!2WM!.!?!M 1111111111111111 Use keys 1 - 8 to select
the days 1 = Sunday
Yes 1 through to 7 = Saturday
(8 = Holiday Date)
e.g. 1 = Sunday
"5/$)!*(!H8!C(=<
The control panel monitors many inputs for fault conditions 3#11111111111111
i.e. the panel lid tamper, bell tamper, aux fuse etc. Yes
Press YES to select
the ‘a’ Off Time
Each one of these options can be disabled to overcome
,08:)0-!"5/$)!*(
problems related to the devices being monitored. 5<!HBB!(:!W+*Z%%
52 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
Yes Yes
5 jkl 6 mno
Yes Yes
Bedtime Arm 2
f7D5:!"$P:!!W.N, ^Edit Text >TXT Press NO followed by YES
Use keys 0 - 9 to program to clear the screen then keep
???? text the same way that a No pressing NO to change between
mobile phone works Yes
upper case, lower case,
numerical and predictive text
!!!.N,!.
!7D5:!"fP:!!f.N, Press NO followed by YES
to clear the screen or keep ^Edit Text >ABC
No pressing NO to change between Use keys 0 - 9 to program
upper case, lower case,
Yes ???? text the same way that a
numerical and predictive text mobile phone works
! Nightime setting
!7D5:!"$P:!!W,?; Edit Text >ab^
???? Yes
.N,!.-()/<!*%%+
!7D5:!"$P:!!W+*f
Text may be assigned to Part Arm 1, 2 or 3 to allow the user
Yes to select the correct Part Arm by description instead of
number. A maximum of 16 characters can be programmed
for each of the Part Arms.
The system has 7 programmable messages.
1 - Reset Message
This 32-character message is displayed whenever the control
! The 3 Part Arm messages are global messages and will
appear whenever one of the part arms are selected
panel requires an Engineer reset. regardless of which area is being part armed.
2 - Anti-code Msg. Text is programmed in a similar way to mobile phones.
This 32-character message is displayed whenever the control Select characters by pressing the corresponding key the
panel requires a Anti-code Reset. appropriate number of times (to select a character on the
3 - Service Message same key, press & to move the cursor along).
This 32-character message is displayed whenever the control
panel requires Daytime reset.
4 - Location Text
This 32-character message is displayed whenever the
engineer views the location text in ‘Engineer Utils’.
5 - Banner Message
This 16-character message is displayed above the time and
date whenever the control panel is unarmed or fully armed.
6 - Part Arm Banner
This 16-character message is displayed above the time and
date whenever the control panel is part armed.
7 - Printer Header
This 16-character header will be printed whenever a log
printout is taken from the control panel or a Short Message
Service (SMS) text message is sent to a mobile phone.
INS176 53
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
V-0E(-!HO:508< V-0E(-!HO:508<
Yes Yes
V-0E(-!HO:508< V-0E(-!HO:508<
3=<:$/!"5/$)< 3=<:$/!"5/$)<
7 pqrs 8 tuv
V-0E(-!HO:508< V-0E(-!HO:508<
i0-5D(=!C(:$< 3O$(G$)!"08$<
Yes Yes
i0-5D(=!C(:$!+W 3O$(G$)!"08$<
!!!!%%]%%]%% 2!.!2!3!7!R!,
Use the SCROLL key Press No to edit
No
to select a Holiday Date the sounder option
i0-5D(=!C(:$!aW 25)$!"08$<
!!!!%%]%%]%% W2!.!2!3!7!R!,
Use keys 1 - 8 to select/deselect
Yes the sounder option or use the
SCROLL key to search
i0-5D(=!C(:$!aW 78:)=!"08$<
!!W!%%]%%]%% 2!.!2!3W7!R!,
Use keys 0 - 9 to enter the Press No to
?????? new date DD/MM/YY No select/deselect
e.g. 030501 = 3rd May 2001 the sounder option
78:$)!8$J!D(:$!W 78:)=!"08$<
!!!!%a]%A]%+ 2!.!2!3WM!R!,
Yes Yes
The system has 8 programmable holiday dates. The speaker output on the control panel can be programmed
so that certain types of tones are not generated. When
The holiday dates are pre-defined dates on which the Control deselected, Fire, Alarms, Fault, Service, Entry, Exit and
Timers will not operate. Chime tones will not be heard.
Example Select tones by pressing keys 1 to 8 (a letter on the display
Control Timer 1 is programmed to operate between the hours means the tone is selected, a Dot on the display means the
of 8pm and 8am on Monday through to Friday (for the tone is not selected).
purpose of arming the control panel).
F - Fire Tones On
Because Bank Holidays normally fall on Mondays the panel Fire alarm tones will be generated by the control panel
would disarm itself leaving the premises unprotected. sounder/speaker.
• Christmas day 2001 falls on a Tuesday
A - Alarm Tones On
• Under normal conditions the Control Timer will operate Intruder alarm, Tamper alarm and PA alarm tones will be
on a Tuesday generated by the control panel sounder/speaker.
• The 25/12/01 is programmed as a Holiday Date F - Fault Tones On
• The Control Timer does not operate on Tuesday 25th Fault tones will be generated by the control panel
December 2001 and the premises remains protected at sounder/speaker.
all times S - Service Tone On
Service and Warning tones will be generated by the control
panel sounder/speaker.
E - Entry Tones On
Entry tones will be generated by the control panel
sounder/speaker.
X - Exit Tones On
Exit tones will be generated by the control panel
sounder/speaker.
C - Chime Tones On
Chime 1, 2 and 3 tones will be generated by the control panel
sounder/speaker.
54 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
V-0E(-!HO:508< V-0E(-!HO:508<
Yes Yes
V-0E(-!HO:508< V-0E(-!HO:508<
3=<:$/!"5/$)< 3=<:$/!"5/$)<
9 wxyz 9 wxyz
V-0E(-!HO:508< V-0E(-!HO:508<
I,!H#:O#:!"$P: ,#<:0/!H]I!"$P:
Yes Yes
! !
I,!H#:O#:!+!"$P: Use keys 1 - 8 to select
,#<:0/!H]I+!"$P: Use keys 1 - 4 to select
a text option or use the a text option or use the
4 ghi SCROLL key to search 3 def SCROLL key to search
i.e. 4 = PC Output 4 Text i.e. 3 = Custom O/P 3 Text
! !
I,!H#:O#:!d!"$P: ,#<:0/!H]Ia!"$P:
Press NO to Press NO to
No edit the text No edit the text
f7D5:!"$P:!!W.N, f7D5:!"$P:!!W.N,
Use keys 0 - 9 to program Use keys 0 - 9 to program
???? text the same way that a ???? text the same way that a
mobile phone works mobile phone works
,$8:)(-!i$(:589 ,0//j<!.6:54$
!7D5:!"$P:!!f.Nf Press NO followed by YES 7D5:!"$P:!!f.Nf
to clear the screen or keep
No pressing NO to change between Yes
upper case, lower case,
Yes
numerical and predictive text
,$8:)(-!i$(:589
!7D5:!"$P:!!W+*f
! Outputs 1 & 2 are silent and outputs 3 & 4 give an
audible warning every 30 seconds for 3 minutes or until
Yes a code is entered or RESET is pressed.
Text is programmed in a similar way to mobile phones.
Select characters by pressing the corresponding key the
Text may be assigned to PC Control Outputs 1 to 8 to allow
appropriate number of times (to select a character on the
the user to select the correct Output by description instead of
number. A maximum of 16 characters can be programmed same key, press & to move the cursor along).
for each of the PC Outputs.
INS176 55
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
??
Use keys 1 - 8 to select an
Press NO area e.g. 2 = B. Use the
to edit the area key to toggle between
keypad areas areas A to H and I to P
Yes
Reset
;QIM*Sa!!'(OO589 No
;QIM*Sa!!'(OO589 Yes ;QIM*Sa!!'(OO589 ???
;QIM*Sa!!'(OO589
^+[!%%%S!^*[!%%% ^+[W%%%S!^*[!%%% ^+[!%%%S!^*[W%%% ^+[!%%%S!^*[W%++
Yes
Reset
;QIM*Sa!HO:508<Z No
I.!C5<(E-$D I.!5<!35-$8: No I.!5<!35-$8:
!M!M!M!"!M!M!M!M WM!M!M!"!M!M!M!M M!M!M!"WM!M!M!M !M!M!M!"W3!M!M!M
Yes
Reset
Yes
Reset
Yes
56 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
• Which areas the sounder and speaker output in the O - Info.LED> Output
keypad will generate tones for i.e. if the keypad is The ‘Info.’ LED on the keypad comes on when the keypad
assigned to areas A and C, the sounder/speaker will only output activates and goes off when the keypad output
operate when areas A or C are in alarm, entry, exit etc. deactivates.
INS176 57
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
3 def
Use keys 1 - 8 to select an
Press NO area e.g. 2 = B. Use the
to edit the area key to toggle between
expander areas areas A to H and I to P
Yes
Reset
Yes
Reset
Yes
Reset
Yes
Reset
Yes
58 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
• Which areas will cause a Tamper alarm when the Expander Sounder Options
expander cover is removed
The speaker output on the expander can be programmed so
that certain types of tones are not generated. When
Expander Location Text deselected, Fire, Alarms, Fault, Service, Entry, Exit and
Each expander can be assigned up to 16 characters of text. Chime tones will not be heard.
This text can be used to describe where the expander is Select tones by pressing keys 1 to 8 (a letter on the display
located within the building. means the tone is selected, a Dot on the display means the
Text is programmed in a similar way to mobile phones. Select tone is not selected).
characters by pressing the corresponding key the F - Fire Tones On
appropriate number of times (to select a character on the Fire alarm tones will be generated by the expander
same key, press the & key to move the cursor along). sounder/speaker.
A - Alarm Tones On
Expander Auxiliary Input Intruder alarm, Tamper alarm and PA alarm tones will be
generated by the expander speaker.
Each expander has an input that can be programmed for one
of the following options. If not being used, the input must be F - Fault Tones On
programmed as ‘Not Used’ (Default = Not Used). Fault tones will be generated by the expander speaker.
Not Used S - Service Tone On
Never monitored by the system. Service and Warning tones will be generated by the expander
Auxiliary Tamper speaker.
Normally used for monitoring the box tamper of auxiliary E - Entry Tones On
devices such as power supplies etc (remove 0V for Tamper Entry tones will be generated by the expander speaker.
alarm).
X - Exit Tones On
Bell Tamper
Exit tones will be generated by the expander speaker.
Normally used for monitoring Bell Tamper returns (remove 0V
for Tamper alarm). C - Chime Tones On
Remote Reset Chime 1, 2 and 3 tones will be generated by the expander
Normally used to reset the system/area following an Intruder speaker.
alarm (the area must also be programmed for Anti-code
reset) see page 43 for details (apply 0V to reset).
Line Fault +ve
Normally used to indicate a telephone line fault (remove 0V
for Line Fault).
Line Fault -ve
Normally used to indicate a telephone line fault (apply 0V for
Line Fault).
Silence Sounders
Normally used to silence the Internal sounders following an
Intruder alarm and would be used in conjunction with Audio
Verification units (apply 0V to silence).
Global Omit Key
Normally wired to a key switch. When the key switch is activated,
all zones (with the ‘Omit’ attribute) assigned to the same area as
the expander, will be omitted (0V removed for omit).
Local Omit Key
Normally wired to a key switch. When the key switch is
activated, all zones (with the ‘Omit’ attribute) wired to the
expander, will be omitted (0V removed for omit).
PSU Monitor
Normally used to monitor a Power Supply for faults, see page
24 for wiring details.
Defer Auto Arming
Normally used to defer the automatic arming of an area
(apply 0V to defer).
INS176 59
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
Yes
System Outputs
Panel Outputs Use keys 1 - 8 to select an
output type or use the
1 SCROLL key to search
e.g. 1 = Digi Outputs
System Outputs
Digi Outputs
Yes
Digi Output 1
Not Used (off)
3 def Enter Output Number e.g. 3
Digi Output 3
Not Used (off)
No
Digi Output 3
> Not Used Press YES to edit
the selected option
1
Digi Output Yes
Enter Output System output>13
> System Type Type e.g. 13 System Open Yes
Digi Output 3 Enter Zone Digi Output 3 Enter Zone Type Digi Output 3 Yes
3 def
> Zone Type
Yes
Number e.g. 011 Zone011<Mimic Yes e.g. 2 (alarm) Zone011>alarm
6 mno
Digi Output 3 Yes
Enter PC Control Digi Output 3
> PC Control Yes
Number e.g. 4 PC Control 4<
6 mno
Digi Output 3 Yes
Enter Door Control Digi Output 3
> Door Control Yes
Number e.g. 4 Door Control>1,4
Digi Output 3
System Open
Yes
Press YES to Accept and move to
If X-10 Outputs are Press NO to Use keys 0 - 9 to select the Unit Number, Then use keys 0 - 9
being programmed edit the House a House Number or use the to select a House Number or use the
& Unit Numbers SCROLL key to search SCROLL key to search
Yes
Yes
60 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
INS176 61
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
INS176 63
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
timer (see page 48 for details) and deactivates when the zone
activity is cleared.
Output Group - Zone
55 - Arm Fail Warning Any zone can be assigned to this output type. Select a zone
This output type activates when the selected area fails to arm number from 1 to 48 (Premier 48), 1 to 88 (Premier 88) or 1 to
after a period of time (controlled by the area exit time) when 168 (Premier 168).then select an output type from the following
using ‘Entry/Exit’ or ‘Exit Term.’ arming and deactivates when options:
the area arms. Mimic
56 - Forced Entry This output type activates when the selected zone is activated
This output type activates for the duration of the ‘Forced and deactivates when the zone is secure. This output will
Entry’ timer (see page 48 for details) when any ‘Guard’ or work if the zone is armed or disarmed.
‘Custom’ zone with the ‘Guard’ attribute is activated (see MimicArm
page 36 for details),. This output type activates when the selected zone is activated
57 - Zones Locked Out and deactivates when the zone is secured. This output will
This output type activates when any zone is locked out only work if the zone is armed.
following an Intruder Alarm activation and deactivates when Alarm
all zones are clear and reinstated. This output type activates when the selected zone causes an
58 - All Areas Armed alarm and deactivates when the alarm is reset. This output
This output type activates when all of the selected areas are will only work if the zone is armed.
armed and deactivates when any one of those areas is Tamper
disarmed. This output type activates when the selected zone causes a
59 - Time Arm Disabled Tamper alarm and deactivates when the tamper is reset. This
This output type activates when the timed arming procedure output will work if the zone is armed or disarmed.
is disabled (see page 37 for details) and deactivates when MimicLat
timed arming is reinstated. This output type activates when the selected zone is activated
60 - Armed/Alarm and deactivates when the next time the zone is activated. This
This output type activates when the selected area is armed output will work if the zone is armed or disarmed.
and deactivates when the selected area is disarmed Omitted
This output type also pulses when an Intruder alarm occurs in the This output type activates when the selected zone is omitted
selected area, and deactivates when the selected area is and deactivates when the zone is reinstated.
disarmed.
61 - Intruder Alarm Output Group - User Code Entered
This output type activates when an Intruder alarm occurs, and
Any user can be assigned to this output type. Select a user
deactivates when the Intruder alarm is cancelled.
number from 1 to 25 (Premier 48), 1 to 50 (Premier 88) or 1 to 99
! Tamper alarms will not activate this output (Premier 168).
This output type activates for 5 seconds when the selected
62 - Speaker Mimic
This output type activates whenever the internal speaker User code is entered.
output is on, and deactivates when the speaker output is off.
63 - Full Armed/Exit Output Group - Control Timer
This output type activates when the selected area is in the full arm
Select a Control Timer from 1 to 4 (Premier 48) or 1 to 8
exit mode and then arms and deactivates when the area is
(Premier 88/168).
disarmed.
These output types activate when the respective control timer
64 - Detector Fault
turns on and deactivate when the timer turns off.
This output type activates when a detector fault occurs and
deactivates when the fault is reset.
65 - Detector Masked
Output Group - PC Control
This output type activates when a detector mask occurs and Select a PC Control from 1 to 4 (Premier 48), 1 to 8 (Premier
deactivates when the mask is reset. 88/168).
66 - Fault Present These output types can be activated and deactivated using a
This output type activates when a general fault occurs i.e. PC running the Wintex UDL software.
Line Fault, AC Mains Fail, Detector Fault etc. and deactivates
when the fault is cleared.
Output Group - Door Control
67 - LED Control
This output type is always activate and deactivates when a Select a Door Control from 1,1 to 1,4 (Premier 48), 1,1 to 1,8
User or Engineers code is entered to gain access to a menu. (Premier 88), 1,1 to 2,8 (Premier 168).
The output activates again 30 seconds after the
These output types activate for the duration of the ‘Door
user/engineer exits the menu. This output type is for use with
Strike’ timer when a valid User code (assigned to the same
detectors that require 0V applied to disable their LED’s.
door) is entered and deactivates when the timer expires.
68 - Full Arm Entry
These output types are used in conjunction with the ‘Door
This output type activates when the entry mode is started and
Control’ User option (see page 88 for details).
deactivates when the entry mode finishes whenever the
system in Full Armed.
INS176 65
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
66 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
\C?]C595!HO:508< \C?]C595!HO:508<
Yes Yes
\C?]C595!HO:508< \C?]C595!HO:508<
;$<$:!C595 ;$<$:!C595
Press RESET to reset the
Yes digimodem - a confimation 2 abc
tone will be heard
\C?]C595!HO:508<
This option should be used whenever a Premier plug-on '3L]I)$[C5(-!L01
communicator is plugged on or removed from the control Yes
panel.
!
f!!!!!!!!!!!W+*a Use keys 0 - 9 to
Start Test Call ????
enter numbers,
Omit = *, Chime = #
Part = 3 second Pause
Area = 10 Second Pause
>73!:0!3$-$6:Z[ Mddk!
\C?]C595!HO:508< !!f!!!!!!!!W+*a
Yes Yes
\C?]C595!HO:508<
;$<$:!C595 When a ComISDN is connected to an extension of an ISDN line
with more than 1 number, the direct dial number should be
1
programmed in here, this ensures that the ComISDN will only
\C?]C595!HO:508<
answer a call when the direct dial number is dialled. This
3:():!"$<:!,(-- number can be up to 24 digits.
Yes
! The Use MSN/Pre-Dial option must also be enabled
(see page 71 for details).
C0!"$<:!,(--!h!%!
,(--!I,h+S*!0)!a!!
Press 0 to send a test call When entering the telephone number the following extra keys
0_ or 1, 2 or 3 to initiate an can be used:
upload to a remote computer
,0/a%%!!5<!_D-$
F(5:!C5(-!"08$
F(5:!C5(-!"08$
C5(--589!L01!+I
C5(--589!L01!+I
?00G589!+<:!i]3
?00G589!+<:!i]3
3$8D589!C(:(
3$8D589!C(:(
F(5:!,-$()!C$-(=
F(5:!,-$()!C$-(=
,0/a%%!5<!_D-$
Menu
INS176 67
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
Program Digi
>73!:0!3$-$6:Z[
\C?]C595!HO:508<
Yes
\C?]C595!HO:508<
;$<$:!C595
3 def
\C?]C595!HO:508<
I)09)(/!C595
Yes
.;,!+!I)0:060-Z
!!C5<(E-$D
Start Use keys 0 - 4 to
Select the required Alarm Press NO to select select a protocol or use
2 abc
Receiving Centre ‘Set’ the protocol the SCROLL key to search
e.g. 2 = ‘Set’ 2
Yes
Yes
Yes
Yes
Yes
Yes
68 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
Yes
Yes
HO$8]6-0<$!08Z No
HO$8]6-0<$!08Z HO$8]6-0<$!08Z
4 ghi
!!!!11111111 !!W!11111111 !!W!111d1111
Yes
Yes
Yes
Yes
Yes
Yes
Yes
INS176 69
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
The plug-on communicator can be programmed to dial up to The following option is only displayed if Contact ID,
3 sets of Alarm Receiving Centre (ARC) information. Each ‘Set’
SIA Level II or EasyCom Pager protocols are selected
consists of the following options:
Reports
Protocol
This option defines which events report to the Alarm
This is the reporting protocol that is used to communicate
Receiving Centre when using Contact ID or SIA Level II.
with the Alarm Receiving Centre. The following 4 protocols
are supported: P - Priority Alarm and Cancel Events
The system will report Priority alarm and cancel events to
• Fast Format: The panel will report using Fast Format. If the selected Alarm Receiving Centre.
this option is selected the ‘Reporting Channels’ must be
programmed (see below) A - Normal Alarm and Cancel Events
The system will report alarm and cancel events to the
• Contact ID: The panel will report using Contact ID. If this selected Alarm Receiving Centre.
option is selected, the ‘Reporting Areas’ must be
programmed (see below) O - Open and Close Events
The system will report open and close events to the
• SIA Level II: The panel will report using SIA Level II selected Alarm Receiving Centre.
• EasyCom Pager: The panel will report to an EasyCom
B - Omit and Reinstate Events
type pager
The system will report omit and reinstate events to the
• SMS Messaging: The panel will send Short Message selected Alarm Receiving Centre.
Service (SMS) text messages to a mobile phone M - Maintenance Alarm Events
Primary Telephone Number The system will report maintenance alarm events to the
This is the first telephone number that the communicator will selected Alarm Receiving Centre.
dial for the Alarm Receiving Centre or the first mobile T - Tamper Alarm Events
telephone number to send SMS to. Each telephone number The system will report tamper alarm events to the
can be up to 24 digits. selected Alarm Receiving Centre.
Secondary Telephone Number C - Test Call Events
This is the second telephone number that the communicator The system will report test call events to the selected
will dial for the Alarm Receiving Centre or the second mobile Alarm Receiving Centre.
telephone number to send SMS to. Each telephone number
can be up to 24 digits. R - Restore Events
The system will report restore events to the selected
Account Number Alarm Receiving Centre.
This is the account number that will be reported to the Alarm
Receiving Centre. Each account number can be up to 6 digits.
! Each area can also have its own account number (see
page 71 for details).
The following option is only displayed if Fast Format
Contact ID or SIA Level II protocols are selected
Dialling Attempts Config.
This is the number of times the communicator will try to dial the This option defines which secondary options are enabled.
Alarm Receiving Centre or Pager telephone number. A - Area Account
Events are reported to the Alarm Receiving Centre using
! The number of dialling attempts is limited to 9. If this value
is set to 0, the communicator will never dial out.
the area account numbers (see page 71 for details).
S - SIA Level I / UCP
Events are reported to the Alarm Receiving Centre using
The following option is only displayed if the
SIA Level I or or to an SMS Messaging Server using UCP.
Fast Format protocol is selected
R - Enable Radio-Pad
Reporting on
The system will use the Paknet radio-pad to report events
This option defines which channels report to the selected
to the selected Alarm Receiving Centre.
Alarm Receiving Centre.
G - Enable GSM Module
Restoring on
The system will use the GSM Module to report events to
This option defines which channels report a restore to the
the selected Alarm Receiving Centre.
selected Alarm Receiving Centre.
A - AV Module
Open/Close on
The AV Module will dial the Alarm Receiving Centre.
This option defines which channels report Open/Close to the
selected Alarm Receiving Centre. F - Use GSM First
The GSM module is the primary path when this is enabled
I - Connect Via IP
The following option is only displayed if Contact ID The system will use the IP Module to report events to the
or SIA Level II protocols are selected selected Alarm Receiving Centre.
70 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
\C?]C595!HO:508< \C?]C595!HO:508<
Yes Yes
\C?]C595!HO:508< \C?]C595!HO:508<
;$<$:!C595 ;$<$:!C595
4 ghi 6 mno
\C?]C595!HO:508< \C?]C595!HO:508<
C595!HO:508< .)$(!.660#8:<
Yes Yes
C595!HO:508< .)$(!.!.660#8:Z
!1!1!1!1!1!1 !!!!![[[[[[
Use keys 1 - 8 to select an
Press NO to edit
No 2 def area or use the SCROLL key
the Digi option
to search e.g. 2 = Area B.
C595!5<!78(E-$D .)$(!N!.660#8:Z
W1!1!1!1!1!1 !!!!![[[[[[
Use keys 1 - 8 to select Press NO to edit
an option or use the No the account number
SCROLL key to search
N-58D!C5(--589 !
!1!1!1W1!1!1! f!!!!!!!!!!!W+*a
Press NO to Use keys 0 - 9 to enter
No select/deselect ???? the account number
the option e.g. 1234 = Account 1234
N-58D!C5(--589 .)$(!N!.660#8:Z
!1!1!1WN!1!1! !!!!![[+*ad
Yes Yes
There are 6 options that control how the plug-on When using Fast Format, Contact ID or SIA, each area can
communicator works. have its own account number to identify events.
Select options by pressing keys 1 to 8 (a letter on the display Account Numbers A to H (I to P)
means the option is selected, a Dot on the display means the This is the account number that will be reported to the Alarm
option is not selected). Receiving Centre. Each account number can be up to 6
digits.
E - Digi is Enabled
The plug-on communicator will report all system events to the
Alarm Receiving Centre. ! In order for the control panel to use the area account
numbers, the area account Config. option must be
P - Pulse Dialling enabled (see page 70 for details).
The plug-on communicator will always dial telephone
numbers using pulse dialling.
3 - Pulse After 3
The plug-on communicator will always dial telephone
numbers using tone dialling. However, if the Communicator
fails to dial the number three times in a row, it will revert to
pulse dialling for the remaining attempts.
B - Blind Dialling
The plug-on communicator will not look for a dial tone before
dialling a telephone number.
U - Use MSN/Pre-Dial
The ComISDN will only answer a call when the programmed
MSN/Pre-Dial telephone number is dialled.
A - Dial All Numbers
If the communicator is acknowledged by the first ARC, it will
continue to dial any other programmed ARC. This is normally
used when a second or third ARC is programmed with SMS
Messaging.
INS176 71
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
UDL Options
>73!:0!3$-$6:Z[
\C?]C595!HO:508<
Yes
\C?]C595!HO:508<
;$<$:!C595
5 jkl
,(--!N(6G!L01!+ No ????
gS%Xl%+*adA&l!
!! f!!!!!!!!!!!W+*a !!!f!!!!!!!!W+*a
Yes
Yes
Yes
Yes
Yes
Yes
Yes
72 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
The system has the following UDL download options: D - Call Defeat
The modem will answer incoming calls as follows:
Download Call Back Number 1
This is the telephone number that is dialled by the modem • The modem must detect one or more rings and the
when ‘Call-back Number 1’ is requested by the remote UDL number of rings must NOT exceed the value set up in
computer. This telephone number can be up to 24 digits. ‘Rings Required’
Download Call Back Number 2 • When the ringing stops, the panel will start a 30
This is the telephone number that is dialled by the modem second delay timer
when ‘Call-back Number 2’ is requested by the remote UDL • If the modem detects ringing before the timer expires
computer. This telephone number can be up to 24 digits. it will answer the call immediately
Download Call Back Number 3 L - Armed DL Limited
This is the telephone number that is dialled by the modem The panel will not allow download access when the system is
when ‘Call-back Number 3’ is requested by the remote UDL armed (also see below).
computer. This telephone number can be up to 24 digits.
A - Any Area Armed
UDL Password is: The panel will not allow download access when any areas are
When the remote downloading computer dials into the system, armed.
the control panel compares the UDL password sent by the
computer with UDL password stored in the control panel. If the K - Online RKP = Off
passwords match, access to the control panel is granted, if The control panel cannot be accessed using the ‘On-line’
they don’t match, access is denied. keypad feature of the Wintex UDL software.
The UDL password programmed in this option must UDL Dial Attempt
also be programmed in the customer account on the If a ‘Call-Back’ is started, this option controls how many times
remote downloading computer. This password can be the modem will try to call the remote downloading computer
up to 16 characters (numbers and letters). before giving up (Default = 003).
INS176 73
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
Radio/SMS Options
>73!:0!3$-$6:Z[
\C?]C595!HO:508<
Yes
\C?]C595!HO:508<
;$<$:!C595
7 pqrs
\C?]C595!HO:508<
;(D50]3'3!HO:508 Use keys 0 - 9 to enter
the telephone number
Use keys 0 - 9 to select Press NO to edit the ARC Omit = *, Chime = #
Yes Press YES to setup an option or use the Primary Radio-Pad Part = 3 second Pause
the Radio-Pad SCROLL key to search telephone number Area = 10 Second Pause
Yes
Menu
Yes
Menu
Yes
Menu
Use keys 0 - 9 to enter
the telephone number
Press NO to edit the Omit = *, Chime = #
SMS Centre Primary Part = 3 second Pause
telephone number Area = 10 Second Pause
The following 6 options
3'3!,$8:)$!I)51! No ???? %lXg%+*adA& will only be seen is a
f!!!!!!!!!!!W+*a !!!!!!!!!!f!W+*a Radio-Pad or GSM
Module is fitted
Yes
I(D!3$)5(-!L01Z
Use keys 0 - 9 to enter !!!%%%%%+*adA&
the telephone number
Press NO to edit the Omit = *, Chime = #
SMS Centre Secondary Part = 3 second Pause
telephone number Area = 10 Second Pause
I(D!L\.Z!+*adA&l
3'3!,$8:)$!3$61 No ???? %lXg%+*adA&
f!!!!!!!!!!!W+*a !!!!!!!!!f!W+*a
Yes
?(<:!,(--!2)0/Z
!!!!(((((((
Press NO to
edit the Modem Use keys 0 - 9 to program text the
setup string same way that a mobile phone works
233Z%+&!bWh%ac
;33Z%Xg!bWhA%c
Yes ,;,Z%%%!beh+%c
N7;Z%%a!beh+%c
Press RESET !
to reset Com 2 !!!!!!!!!!!!,0/*
74 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
The following options are used when a Paknet Radio-Pad is Setup IP Module
connected to the control panel in order to achieve DUAL
SIGNALLING to an Alarm Receiving Centre, when a MODEM ComIP Address
(External PC or Com2400) is used to connect to the control This is the IP Address of the IP Module.
panel or send SMS messages to mobile phones, when an AV ComIP Port
Module is connected to the control panel in order to achieve This is the Port number of the IP Module.
AUDIO VERIFICATION to an Alarm Receiving Centre or when
a TCP/IP Module is connected for communications over a ComIP Gateway
Broadband/ADSL/DSL Line. This is the Gateway IP Address that the IP Module
communicates through.
Setup Radio-Pad ComIP Mask
This is the Subnet Mask number for the IP Module.
Pad ARC 1 Pri No
This is the first number that is used by the Radio-Pad for Polling/SMG Address
reporting events to ARC 1. This is the IP address of a dedicated Polling or SMG Server
that the IP Module might need to connect to.
Pad ARC 1 Sec No
This is the second number that is used by the Radio-Pad for Name/SMG Port
reporting events to ARC 1. This is a descriptive name for the IP Module or SMG Port and
might be used for authentication purposes.
Pad ARC 1 Prefix
This number will prefix the account number for ARC 1.
Pad ARC 2 Pri No SMS Centre Pri.
This is the first number that is used by the Radio-Pad for This is the first SMS centre telephone number that is used by
reporting events to ARC 2. for sending SMS to mobile phones. (Default = 07860
980480).
Pad ARC 2 Sec No
This is the second number that is used by the Radio-Pad for SMS Centre Sec.
reporting events to ARC 2. This is the second SMS centre telephone number that is used
by for sending SMS to mobile phones.
Pad ARC 2 Prefix
This number will prefix the account number for ARC 2. Modem Setup Stg.
If a standard PC modem is connected to Com1 or Com2, it
Pad ARC 3 Pri No may require a configuration string to make it work properly
This is the first number that is used by the Radio-Pad for (please refer to instruction manual of modem being used for
reporting events to ARC 3. details of required AT commands).
Pad ARC 3 Sec No
This is the second number that is used by the Radio-Pad for ! The Setup string is programmed the same way that
TEXT would be programmed and has a maximum
reporting events to ARC 3. length of 16 characters.
Pad ARC 3 Prefix The setup string does NOT require AT to be entered at
This number will prefix the account number for ARC 3. the beginning as this is done automatically.
Radio-Pad Attempts Modem Speed
This is the number of times the Radio-Pad will try to dial the This option allows the speed of a standard PC modem
Alarm Receiving Centre telephone number before giving up. connected to Com1 or Com2 to be adjusted.
INS176 75
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
76 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
Com1
Com Port Setup This option determines what type of device is connected to
the Com1 connector on the left hand side of the control
>73!:0!3$-$6:Z[ panel. (Default = No Module Fitted).
\C?]C595!HO:508<
The following devices are available from the above list:
Yes
0 / 2 / 3 / 4 / 5 / 7 / 8 / 9 / 10 / 12 / 13 / 14
\C?]C595!HO:508<
;$<$:!C595
8 tuv
! If any of the above devices are connected to the
control panel on Com1 and a PC needs to be
connected (for uploading/downloading) the device
\C?]C595!HO:508< must be disconnected from Com 1 and the ‘Factory
,0/!I0):!3$:#O
Default’ button pressed for 3 seconds to allow the PC
Yes to talk to the control panel.
,0/!I0):!+ Com2
L0!'0D#-$!25::$D This option determines what type of device is connected to
Press NO to edit the Com2 connector on the left hand side of the control
No
the Com Port panel. (Default = No Module Fitted).
,0/!I0):!+ The following devices are available from the above list:
L0!'0D#-$!25::$e
Use keys 0 - 8 to select
an device or use the
0 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 11 / 12 / 13 / 14
7 pqrs
SCROLL key to search
e.g. 7 = GSM Module
Expansion Port
,0/!I0):!+
V3'!'0D#-$!!!!!e This option determines what type of device is connected to the
Expansion Port connector (Default = No Module Fitted).
Yes
Available Device Types:
The control panel must be programmed with the type of 0: No Module Fitted - No Devices
device that are connected to each of its coms ports. 1: AV Module - Premier Audio Verification Module
2: iD Module - Premier 60IXD iD Module
Onboard Digicom, Com Port 1 and 2 3: X10 Module - X10 Controller
The following devices are available for fitting to the various 4: Premier OP8 - Premier Output Module (8 Outputs)
ports: 5:Memory Module – Premier Memory Module
0: No Module Fitted - No Devices/PC-Com/ USB-Com
1: Com300 - Com300 Communicator.
2: Com2400 - Com2400 Communicator.
! Selecting memory module when none is fitted will
prevent events being recorded to the log.
3: ComISDN - ComISDN Communicator.
4: ComIP - ComIP TCP/IP Communication Module.
5: Modem Unit - Standard Serial PC Modem.
6: Radio Pad - Paknet RP9 Radio-Pad.
7: GSM Module - GSM Module/Mobile Phone.
8: Crestron System - Crestron Home Automation System.
9: SIP - Serial IP Protocol.
10: RadioPlus - Premier Serial Wireless Receiver.
11: Inovonics Radio - Inovonics Serial Wireless Receiver.
12: WebWayOne - WebWayOne UDP Module.
13: X-10 Control - X-10 Home Automation Module.
14: IRIS IP - Chiron IRIS Serial TCP/IP Module.
Onboard Digicom
This option determines what type of device is connected to
the plug-on digmodem connector on the top right hand
corner of the control panel. (Default = Com300).
The following devices are available from the above list:
0/1/2/3
INS176 77
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
78 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
INS176 79
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
80 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
INS176 81
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
82 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
Device ID Device ID
Panel 000 Panel 00
RedCARE 01
Keypad ID is transmitted as follows: Com300 03
Network
RKP 1 2 3 4 5 6 7 8 Expander ID is transmitted as follows:
1 11 21 31 41 51 61 71 81 Network
2 12 22 32 42 52 62 72 82 EXP 1 2 3 4 5 6 7 8
3 13 23 33 43 53 63 73 83 1 11 21 31 41 51 61 71 81
4 14 24 34 44 54 64 74 84 2 12 22 32 42 52 62 72 82
5 15 25 35 45 55 65 75 85 3 13 23 33 43 53 63 73 83
6 16 26 36 46 56 66 76 86 4 14 24 34 44 54 64 74 84
7 17 27 37 47 57 67 77 87 5 15 25 35 45 55 65 75 85
8 18 28 38 48 58 68 78 88 6 16 26 36 46 56 66 76 86
7 17 27 37 47 57 67 77 87
8 18 28 38 48 58 68 78 88
Expander ID is transmitted as follows:
Network
Reset ID ****
EXP 1 2 3 4 5 6 7 8
Reset ID is transmitted as follows:
1 11 21 31 41 51 61 71 81
2 12 22 32 42 52 62 72 82 Device ID
3 13 23 33 43 53 63 73 83 Panel (RR) 00
4 14 24 34 44 54 64 74 84 Engineer 01
5 15 25 35 45 55 65 75 85 Anti-Code 02
6 16 26 36 46 56 66 76 86 RedCARE 03
7 17 27 37 47 57 67 77 87 Keyswitch 04
8 18 28 38 48 58 68 78 88 User 05
Wintex 07
Network
EXP 1 2 3 4 5 6 7 8
1 11 21 31 41 51 61 71 81
2 12 22 32 42 52 62 72 82
3 13 23 33 43 53 63 73 83
4 14 24 34 44 54 64 74 84
5 15 25 35 45 55 65 75 85
6 16 26 36 46 56 66 76 86
7 17 27 37 47 57 67 77 87
8 18 28 38 48 58 68 78 88
INS176 83
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
1 ASSIGNING TAG
YES to Select:- Present TAG Now! Present TAG to
Setup Users
assign it to user
Area Add TAG to User? 2 IMPORTING TAG
1=New, 2=Import Present TAG Now!
Yes
Enter User Number Press NO to exit ‘Add TAG’
i.e. 10 = User 10 Routine
Setup Users ??
Setup Users Reset Do You Want to Press YES to delete the
User002: Enter User010: DELETE User 010? User from ths system
Yes Yes
Allow Arming
Enter User code number >A D O . . . . F
4, 5 or 6 digits long Use keys 1 - 8 to select
e.g. 1234 = 1234 a User option or use the
SCROLL key to search
Enter User Code> Enter User Code>
------ ???? --1234 Auto ?Yes?
A D O . . .>. F
Press NO to
Yes Yes No select/deselect
the User option
User 10 Areas > 2 abc User 10 Areas > If the User If the User Menu option is
> A******* < > AB****** < menu option selected, the ‘User Config’
is not selected menu will be displayed
Yes Yes
Yes
Yes
Yes Press NO to Use the keypad to program
edit the User text the same way that a
name text mobile phone works
Yes OPTIONAL
Yes
1 ASSIGNING TAG
Present TAG Now! Present the Proximity TAG
Add TAG to User? to the ‘Prox’ symbol on the
1=New, 2=Import keypad and a beep will be heard
2 IMPORTING TAG
Present TAG Now!
No
84 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
INS176 85
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
5: Duress 8: Vacation
Duress users behave the same way as Standard users. Vacation users behave the same way as Standard users.
However, Duress users will activate any outputs programmed However, Vacation users will automatically be deleted the first
as ‘Panic Alarm’ or ‘Duress’ whenever their code is entered. time that the Master User code (User 01) is used to disarm
the system.
! Duress users can only be set up by an Engineer if system
is set to Grade 3 – see configuration option 37. ! Vacation user can only be deleted by the Master user
after it has been used to disarm the system at least
once.
6: Arm Only
Arm Only users can only arm or reset their assigned areas
9: Custom
and view the event log.
Custom users can access any functions and User menu
7: Door Strike options that have been assigned to them in ‘User Options 1
Door Strike users have no access to User functions or Menu or 2’ and ‘User Config’. This flexibility allows new User types
options. However, Door Strike users will activate any outputs to be created that have their own unique set of
programmed as ‘Door Strike’ whenever their code is entered characteristics. Any number of Custom users can be
(see page 64 for details). assigned to the system and each one will respond differently,
depending on the functions and features that have been
assigned to them.
! All users that have access to the ‘Arming Menu’ have the ability to ‘View Zone Status’, ‘Set Chime Areas’, ‘View Act.
Faults’ and ‘View Act. Counts’.
All users have access to the ‘User Menu’ have the ability to ‘View Event Log’, ‘Adjust Volumes’ and ‘Print Event Log’.
User Options 1
Engineer Master Manager Standard Local Duress Arm Only Door Strike Vacation Custom
Eng. Reset - - - - - - - - -
- - - - Local Arming - - - - -
- - - - Local Disarm - - - - -
- - - - - - - - - -
Disarm First Disarm First Disarm First Disarm First Disarm First Disarm First - - Disarm First -
User Options 2
User Menu User Menu User Menu User Menu User Menu - User Menu - User Menu -
Eng. Program - - - - - - - - -
- - - - - - - - - -
- - - - - - - - Vacation -
- - - - - Duress Code - - - -
Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close - Open/Close -
User Config.
Engineer Master Manager Standard Local Duress Arm Only Door Strike Vacation Not Used
Change Code Change Code Change Code Change Code Change Code - - - - -
Chime Zones Chime Zones Chime Zones Chime Zones Chime Zones - - - - -
Eng. Access Eng. Access Eng. Access Eng. Access Eng. Access - Eng. Access - Eng. Access -
NVM Locking - - - - - - - - -
86 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
Press & to scroll through the options and press 3 to This menu defines which options are available to the user
select them or use keys # - + (‘Letter’ = option IS when their code is entered.
selected, ‘Star’ = option is NOT selected).
Press & to scroll through the options and press 3 to
The following options are available: select them or use keys # - + (‘Letter’ = option IS
selected, ‘Star’ = option is NOT selected).
A - Arming
Areas assigned to the selected user can be armed. The following options are available:
D - Disarming U - User Menu
Areas assigned to the selected user can be disarmed. The selected user has access to the User menu. However,
the selected user will only have access to options assigned in
O - Omitting
‘User Config.’ (see page 88 for details).
Zones assigned to the same areas as the selected user can
be omitted, providing that they have the ‘omit’ attribute E - Eng. Program (Engineers only)
assigned to them. Only Available to Engineers.
R - Eng. Reset (Engineers only) D - Dual Code
Areas programmed as ‘Engineer reset’ can be reset after an The selected user can only access an area when a second
Alarm has occurred. User code (with the ‘Dual Code’ attribute and also assigned
to the same area) is entered. Dual Code users will also
a - Local Arming
activate the ‘1st and 2nd Code’ output type.
The User can only arm areas that the keypad is assigned to.
V - Vacation
d - Local Disarm
The selected user is enabled the first time it is used to disarm
The User can only disarm areas that the keypad is assigned to,
the system and can be used as many times as required.
or areas that are in entry or alarm (provided that the code has
However, it will be automatically deleted the first time that the
that area assigned to it).
User 01 code is used to disarm. Vacation users will only be
Y - Auto ‘YES’ deleted by the Master user, once they have been used on the
After a User code has been entered, pressing the 0 key to system.
confirm the next action is not required. S - Door Strike
F - Disarm First The selected user will activate any outputs programmed as
If an area is already armed and the selected user enters their ‘Door Strike’, whenever their codes are entered.
code, the ‘Disarm’ option is displayed. R - Call Rem. PC
The selected user has access to the ‘Call Remote PC’ option,
allowing them to initiate a call to a remote upload/download
PC.
C - Duress Code
The selected user will activate any outputs programmed as
‘Duress’, whenever their codes are entered.
O - Open/Close
The selected user will report open (disarm) and close (arm)
events to an Alarm Receiving Centre every time they arm or
disarm.
INS176 87
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
This allows conditions to be set up in the custom outputs and Press 0 to confirm deletion of the selected User code
then the TAG or Code to be locked out during those
Press ! to exit from Setup Users
conditions i.e. Custom Output 2 Stage B could be
programmed to activate during entry, resulting in the code
being disabled during the entry period.
88 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
1=Event,2=Alarm
3=Mandatory Log
Use keys 1, 2 or 3 to select the The System Log records the last 500 (Premier 48), 1000
1 System, Alarm or Madatory
log i.e. 1= System Log
(Premier 88) or 2000 (Premier 168) events.
PROG. START The Alarm Log records the last 32 alarm events.
12:28.04 06/03 Use the SCROLL key to move up and
down through the log. DOWN moves to The Mandatory Log records the last 500 mandatory events.
the previous event (backwards in time)
and UP moves forwards again. Or
use one of the available hotkeys Event Log Hotkeys
Code 01 David
12:28.04 06/03 When viewing the system log there are 9 hotkeys available.
Press CHIME. to find any
preceding events relating to These hotkeys allow certain events to be found easier without
Chime
the displayed event i.e. the need for searching.
User codes being entered
Code 12 John The following hotkeys are available:
12:28.04 06/03
Area
Press AREA. to toggle the
display between the Area # = Priority Alarms (PA, Fire etc.)
information and the time/date
$ = Normal Alarms (Guard, 24hr, Entry/Exit etc.)
Code 01 David
Area: A.......
% = Opens and Closings (Arm, Disarm etc.)
Press PART to display any " = Omits and Reinstates (Zone Omits etc.)
Part
programmed zone text etc. ( = Maintenance (System Tests, Engineer Program etc.)
Code 01 David ) = Tampers (Zone, Bell, Aux etc.)
Area: A....... * = Test Calls (Communicator Active, successful etc.)
Menu + = Entry/Exit (Entry and Exit Procedures)
' = User Codes (User codes being used)
INS176 89
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
90 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
INS176 91
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
78958$$)!\:5-< 78958$$)!\:5-<
Yes Yes
78958$$)!\:5-< 78958$$)!\:5-<
T5$J!74$8:!?09 T5$J!74$8:!?09
2 abc 2 abc
78958$$)!\:5-< 78958$$)!\:5-<
C0!N$--!"$<: C0!J(-G!:$<:`
Yes Yes
I#<K!>73!:0!:$<: F(-G!:$<:!.)$(<W
N$--!5<!!!!!WHBB !!W!.N,C72Vi!e
Press OMIT to invoke the Press YES to walk test all
Omit Engineers Hold Off mode Yes areas or use keys 1 - 8
of a Texecom Bellbox to select/deselect areas
I#<K!>73!:0!:$<: !!!M!LHL7!M
N$--!C5<(E-$D
Press CHIME to select:
Use the SCROLL key to Chime Once then lockout zone
Chime
select the required test Chime on every activation
or No Chime at all
I#<K!>73!:0!:$<: ^08$!%%A
C595!W!!MMMMMMMM ?0#89$!I_;!!!!
Press YES to test ALL Press AREA. to toggle the
channels or use keys 0 - 8 display between the zones
3 def Area
to select individual channels that have been tested and
e.g. 3 = Channel 3 the zones that still need testing
I#<K!>73!:0!:$<: ^08$<!:K(:!8$$D
C595!W!!MMMMMMMM Press YES again to clear ALL
:$<:589!()$!Z To view zones that have not
channels or use keys 0 - 8 activated recently, enter the
3 def ??? number of days required
to clear individual channels
e.g. 3 = Channel 3 i.e. 007 will show zones that have
not activated in the last 7 days
I#<K!>73!:0!:$<: ^08$!%%+!!!!W%%l
C595!W!!MMMMMMMM 2)08:!C00)
Menu Menu
This option allows Allows the Bell, Speaker and various Any of the zones on the system can be walk tested to ensure
control panel outputs to be tested. that they operate correctly. A walk test can only be performed
when the system or area is disarmed.
The following outputs can be individually tested:
Test Bell The Bell output ! Once a zone has been activated it will not generate a
chime tone again. If however the 2 key is pressed, a
Test Strobe The Strobe output zone will chime every time it is activated.
Test Speaker The Speaker output
The Walk test menu also includes a last activation log that
Test Digi The Hardwired digicom outputs
can be recalled when doing a walk test. This log shows zones
Test Panel The panel outputs that have NOT been activated over a period of days.
Test RedCARE The plug on RedCARE outputs
Pressing the 6 key will firstly show the zones that still need
Test Com???? The plug on Com 300/2400 digi
testing, pressing the 6 key a second time will display the
channels
zones that have not been activated that day, to view zones
LCD Display The LCD keypad display that have not been activated for 3 days, type in 003 the
User Outputs Any outputs that have the ‘User Test’ maximum number of days that can be recalled is 255,
attribute (see page 66 for details). pressing the 6 key a third time will revert back to the
standard walk test display.
! Pressing OMIT at the Bell or Strobe Test will cause the
Strobe output to pulse 3 times, invoking Engineers
Hold Off mode if a Texecom bell box is connected.
92 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
78958$$)!\:5-< 78958$$)!\:5-<
Yes Yes
78958$$)!\:5-< 78958$$)!\:5-<
T5$J!74$8:!?09 T5$J!74$8:!?09
3 def 4 ghi
78958$$)!\:5-< 78958$$)!\:5-<
T5$J!^08$!3:(:#< 3=<:$/!"$<:<
Yes Yes
^08$!%%+!I(8$-!+ C0!=0#!J(8:!:0
3$6#)$!!!!!!!*G* T5$J!3=<1!3:(:#<
Use keys 0 - 9 to enter the Use keys 1 - 4 to select
required zone number or an option or use the
??? Yes
use the SCROLL key to search SCROLL key to search
e.g. 064 = Zone 64 e.g. YES = View Sys. Status
^08$!%&d!L+S7lSX 3=<!T0-:(9$W+a1l
3$6#)$!!!!!!!*G* 3=<!,#))$8:W%&Xg
^08$!%&d!L+S7lSX Menu
.6:54$!!!!!!!&Gg To disable the zone,
Press OMIT.
To make the zone Chime,
Omit
Press CHIME
To view the zone text,
This option allows various control panel features to be tested
^08$R%&d!L+S7lSX Press AREA or reviewed.
^08$!C5<(E-$D
1 - View Sys. Status
Menu Allows the system voltage and current to be viewed.
2 - View Batt Status
This option can be used to view the status of any zone on the Allows the battery voltage and charging status to be viewed.
system to see whether it is ‘Active’, ‘Secure’, ‘Tampered’ or
‘Shorted’. The selected zone can also be temporarily disabled 3 - Test Outputs
(zone and tamper) to allow the zone to be worked on or made Allows the Bell, Speaker and system outputs to be tested.
to chime every time it is activated. 4 - View Version No.
This option allows the control panel software version and
! When leaving the View Zone Status menu, all zones
will be automatically reinstated and cleared of Chime.
serial number to be viewed.
INS176 93
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
78958$$)!\:5-< 78958$$)!\:5-<
Yes Yes
78958$$)!\:5-< 78958$$)!\:5-<
T5$J!74$8:!?09 T5$J!74$8:!?09
5 jkl 6 mno
78958$$)!\:5-< 78958$$)!\:5-<
,08B5)/!C$456$< T5$J!;QI!3:(:#<
Yes Yes
Menu
78958$$)!\:5-<
T5$J!7PO1!3:(:#<
Yes
This option allows the networks to be viewed to see what
devices are connected and whether there are any problems. L+S7+!!!+*adA&lX
Whenever new devices are added to the system, the !!ML0:!25::$DM
Use keys 1 - 8 to select an
networks must be checked and confirmed. ??
expander and press 0 to
toggle between networks e.g.
Menu
94 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
78958$$)!\:5-< 78958$$)!\:5-<
Yes Yes
78958$$)!\:5-< 78958$$)!\:5-<
T5$J!74$8:!?09 T5$J!74$8:!?09
8 tuv
78958$$)!\:5-< 78958$$)!\:5-<
3$:!3=<:$/!"5/$` ,K(89$!7891!,0D$
Yes Yes
78:$)!8$J!:5/$!W 78:$)!L$J!,0D$!W
!!!!!%%Z%% !!!!![[[[[[
Use keys 0 - 9 to enter the Enter User code number
???? new time (24-Hour format) ???? 4, 5 or 6 digits long
e.g. 1645 = 4:45 pm e.g. 1234 = 1234
78:$)!8$J!:5/$!W 78:$)!L$J!,0D$!W
!!!!!+&ZdA !!!!![[+*ad
Yes Yes
The control panel has a real time clock that is used to date This option allows the Engineer code (User 00) to be changed.
and time stamp events that are recorded within the system This code can be 4, 5 or 6 digits in length. The system will
log. The option allows you to set the control panel time. allow a mixture of different length User codes.
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
78958$$)!\:5-< 78958$$)!\:5-<
Yes Yes
78958$$)!\:5-< 78958$$)!\:5-<
T5$J!74$8:!?09 T5$J!74$8:!?09
9 wxyz
78958$$)!\:5-< 78958$$)!\:5-<
3$:!3=<:$/!C(:$` .Dn#<:!T0-#/$<
Yes Yes
78:$)!8$J!D(:$!W I(8$-!T0-#/$
!!!!%+]%+]%+ !!?$4$-!h!&
Use keys 0 - 9 to enter the Use the SCROLL key
?????? new date DD/MM/YY to select a Panel, Keypad
e.g. 030501 = 3rd May 2001 or Expander Speaker
78:$)!8$J!D(:$!W Q$=O(D!%a!T0-#/$
!!!!%a]%A]%+ !!!?$4$-!h!d
Yes No
Q$=O(D!%a!T0-#/$
The control panel has a real time clock that is used to date !!!?$4$-!hWd
Enter a value or use the
and time stamp events that are recorded within the system 8 tuv
SCROLL key to increase
or decrease the value
log. The option allows you to set the control panel date. e.g. 8 = Full Volume
Q$=O(D!%a!T0-#/$
!!!?$4$-!hWl
Menu
INS176 95
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
>73!:0!3$-$6:Z[ >73!:0!3$-$6:Z[
78958$$)!\:5-< 78958$$)!\:5-<
3 def Yes
78958$$)!\:5-< 78958$$)!\:5-<
T5$J!74$8:!?09 T5$J!74$8:!?09
78958$$)!\:5-< 78958$$)!\:5-<
C$B(#-:!LT'!C(:( I)58:!?09!C(:(
Yes Yes
I)$<<!>73!;$<$:Z L#/E$)!0B!74$8:<Z
I(8$-!H#:O#:< !!!!!W!%%%% Enter a value or use the
Use keys 0 - 9 to select
an option or use the SCROLL key to increase
3 def ????
SCROLL key to search or decrease the value
e.g. 3 = Keypad Outputs e.g. 50 = Last 50 Events
I)$<<!>73!;$<$:Z L#/E$)!0B!74$8:<Z
Q$=O(D!H#:O#:< !!!!!W!%%A%
Press YES to default Press YES
Yes Yes
the option to print
Q$=O(D!H#:O#:<
M!I-$(<$!F(5:@!M This option allows the ‘Event Log’ to be printed to a standard
Menu
RS232 printer (see page 27 for details).
Yes
Location Text
78958$$)!\:5-<
T5$J!74$8:!?09
>73!:0!3$-$6:Z[
78958$$)!\:5-<
Yes
78958$$)!\:5-<
30(G!"$<:!.)$(<
78958$$)!\:5-<
T5$J!74$8:!?09 Yes
30(G!"$<:!.)$(<Z
!!W!.M111111!e!
Use keys 1 - 8 to select
78958$$)!\:5-< areas e.g. 2 = B. Use the
?06(:508!"$P: 2 abc
area key to toggle between
areas A to H and I to P
Yes
30(G!"$<:!.)$(<Z
!!W!.N111111!e!
L0!?06(:508!"$P:
!i(<!N$$8!3$:#O Press YES to default
Yes
the option
Yes
96 INS176
Premier 48, 88 & 168 Installation Manual Programming the Control Panel
Yes Yes
1111101010100011 %+Z!_C%%%%%%!!HQ
..............1N 3?Z%%%!!^08$!%%%
Use keys 0 - 9 to enter the
Press 0 to toggle between
required device number or
0 iD Loop 1 and 2 ??
use the SCROLL key to search
The status of the zones
e.g. 23 = Device 23
will be displayed
0000111001100111 *aZ!_C%%%%%%!!HQ
..............2N 3?Z%%%!!^08$!%%%
Press Area to toggle
between Normal loop scan Press YES to learn
Area Yes
Quick loop scan and Radio Device
Biscuit Mapping
0000111001100111 *aZ!_C111111!".'I
..............2Q .6:54(:$!C$456$
Area Activate the Tamper
on the Device
iD Loop 1,01
Mapped Zone 000
Press 0 to toggle between *aZ!_C*d*g%%!!HQ
iD Loop 1 and 2. 3?Z%XA!!^08$!%%%
Use Scroll keys to select the
Press NO to map the
required iD biscuit. No
device to a zone/user
Press No to edit
the zone mapping and
*aZ!_C*d*g%%!!HQ
No 3?Z%XA!!^08$W%%%
wiring options. Use keys 0 - 9 to enter the
required zone/user number or
iD Loop 1,01 ???
use the SCROLL key to search
Mapped Zone>000 e.g. 64 = Zone 64
Use keys 0 - 9 to enter *aZ!_C*d*g%%!!HQ
???? 3?Z%XA!!^08$W%&d
the zone number
Yes
Configuring Radio devices
iD Loop 1,01 Up to 32 wireless devices can be learnt on to the system this
Mapped Zone 010*
can be any combination of detectors, mag contacts and
Menu remote FOBs. The number of remote FOBs is limited to the
maximum number of users (ie 24 0n the Premier 48).
Wireless devices can then be mapped on to the system along
Viewing the iD Data with conventional detectors.
This option allows the 60IXD expander the iD biscuit data to The top line on the display shows the serial number of the
be viewed to diagnostic purposes. There are two way of device and also the status i.e. Active, Tamper etc.
viewing the data from the expander:
The bottom line of the display shows the signal strength and
Normal Scan Mode also which zone/user the device is mapped to.
This is the normal operation mode of the expander and the
data being displayed is the average result of 4 successive ! Signal strength should be greater than 30.
scans of the iD loop. The signal range is between 0 and 90
Quick Scan Mode See Radio-Plus installation manual for full details.
In this mode the data being displayed is the result of each
scan of the iD loop. This mode is useful for identifying
problems with biscuits due to interference, high resistance
connections etc.
“iD” is a registered trade mark of Chloride Safety System Limited.
INS176 97
Programming the Control Panel Premier 48, 88 & 168 Installation Manual
>73!:0!3$-$6:Z[
^08$!3$:#O
Part
>73!:0!3$-$6:Z[
.-:$)!I():!.)/<
Yes
20)!I():!.)/!+
^08$!%%+!5<!W!HL Press OMIT to select Part Arm 1
Press CHIME to select Part Arm 2
Chime Press PART to select Part Arm 3
e.g. CHIME = Part Arm 2
20)!I():!.)/!*
^08$!%%+!5<!W!HL Use keys 0 - 9 to enter the
required zone number or
??? use the SCROLL key to search
e.g. 064 = Zone 10
20)!I():!.)/!*
^08$!%+%!5<!W!HL
Press NO to turn the
No zone On or Off for the
selected Part Arm
20)!I():!.)/!*
^08$!%+%!5<!WH22
Yes
98 INS176
Premier 48, 88 & 168 Installation Manual Specifications
6. Specifications
Control Panel EOL Resistor Values (Alternatives Available)
EOL Resistor 2k2 (3k3)
Power supply Contact Resistor 4k7 (3k3)
Mains Supply Voltage: 230VAC (±10%) Fault Resistor 2k2
0 - 1k Zone Short
Maximum Total Current Rating
1k1 to 4k Zone Secure
16.5VAC, 40VA transformer: 2.0ADC
4k1 to 5k6 Zone Fault
Ripple <5% 5k7 to 8k Zone Active
Power Supply 2A 8k1 to 20k (30k) Zone Mask
21k+ (30k+) Zone Tamper
Battery Charging Current 750mA
Digicom Outputs
Maximum Available Current 1.25A
Outputs 1 to 8 100mA switched to 0V
PD6662 Rated Output See Page 12
Panel Outputs
Standby Battery Capacity 7Ah to 18Ah Outputs 1 & 2 (48/88/168) 500mA switched to 0V
Recharge Time <24Hrs Outputs 3 & 4 (88/168) 500mA switched to 12V
Output 5 (88/168) 3 Amp Relay
Low Battery Fault 10.5V
Siren Outputs
Deep Discharge Protection 9.5V
Bell Trigger 1A switched to 0V
Strobe Trigger 1A switched to 0V
Electrical
Speaker Output Minimum load 8Ω
Current Consumption 48/88/168
Quiescent 70mA Environmental
Alarm (Nothing Connected) 70mA
Operating Temperature -10°C (+14°F) to
Fuses +55°C (+131°F)
Mains (2.0ADC) 500mA, 250V, 20mm
Storage Temperature -20°C (-4°F) to
Battery 1.6 Amp, 250V, PTC +60°C (+140°F)
Auxiliary 1 Amp, 250V, 20mm
Maximum Humidity 95% non-condensing
Bell 1 Amp, 250V, 20mm
Network 1 (48/88/168) 1 Amp, 250V, 20mm EMC Environment Residential
Network 2 (168) 1 Amp, 250V, 20mm Commercial
Light Industrial
Data Network 4-wire standard 7/0.2
alarm cable up to 500m Industrial
Star, Daisy Chain or any
combination of the two Physical
Remote Keypads Housing Metal
Premier 48 Up to 4 Dimensions (W x H x D) 305mm x 405mm x
Premier 88 Up to 8 100mm x 2mm Steel
Premier 168 Up to 16 Battery Compartment Up to two 12V 7.0Ah
batteries or one 12V 18Ah
Expanders battery
Premier 48 Up to 4 Packed Weight 5.5 Kg
Premier 88 Up to 8
Premier 168 Up to 16
Output Modules
Premier 48 Up to 2
Premier 88 Up to 4
Premier 168 Up to 8
Zones
Premier 48 8 expandable to 48
Premier 88 8 expandable to 88
Premier 168 8 expandable to 168
INS176 99
Specifications Premier 48, 88 & 168 Installation Manual
Physical
Environmental
Dimensions (W x H x D) 170mm x 140mm x 35mm
Operating Temperature -10°C (+14°F) to
+55°C (+131°F) Packed Weight 200g Approx.
Physical
Dimensions (W x H x D) 145mm x 115mm x 30mm
Packed Weight 260g Approx.
100 INS176
Premier 48, 88 & 168 Installation Manual Specifications
INS176 101
Specifications Premier 48, 88 & 168 Installation Manual
Declaration of Conformity
(D0247-99 Rev04)
This is to confirm that this product meets all essential protection requirements relating to:
The assessment of this product has been based on the following standards:
Texecom Ltd.
Bradwood Court
St. Crispin Way
Haslingdon
BB4 4PW
R J Austen
Vice Chairman
12 July 2007
102 INS176
Premier 48, 88 & 168 Installation Manual Notes
INS176 103
Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW,
England.
Technical Support:
UK Customers Tel: 08456 300 600
(Calls charged at 3.36 pence per minute from a BT landline. Calls from other networks may vary.)
International Customers Tel: +44 1278 411707
Email: techsupport@texe.com