MULTI-HEAT

STOKER BOILER FOR BIO-FUEL


WOOD PELLETS, WOOD CHIPS, GRAIN/CORN

Easy
to operate

Unusually
high
I Environmentally

j
I friendly heating

Certified in
H accordance with I
efficiency • DS/EN ISO 90011

BAXI
Make yourself independent of carbon taxes, oil price increases and fossil fuels:
Fully automatic stoker boiler with hopper
for detached houses - agriculture - trade and business
The MULTI-HEAT type is especially suit- Construction and function The hopper must typically be filled up once
able for effective and environmentally or twice a week during cold weather,
The construction of the boiler gives high
friendly firing with bio-fuels such as wood however, this will depend on the heat requi-
operational security, significant durability,
pellets, wood chips and grain/corn. Please rement, hopper size and fuel. The possibility
good stoking economy, environmentally
consult the importer (or the factory) regar- of automatic feeding of fuel is also avail-
friendly combustion and simple operation.
ding possible use of other fuels. able. Ash is removed as required.
Depending on the heating requirement, the
feeder mechanism automatically leads a
Significant savings suitable quantity of fuel into the combustion A heat storage tank
chamber. Here the build-in blower produces
on your heat bills a precise mixture of primary and secondary
is unnecessary
The stoker boiler is especially applicable for air, resulting in a very high efficiency at The boiler output can be regulated from
owners of detached houses and the agricul- 89-91%. 100% down to 30% during continuous ope-
tural sector outside of the collective grid The temperature is regulated by a two-step ration and - by stoking at intervals - as low
energy systems (i.e. areas without district control. This means that the boiler is run- as approx. 1 kW. In order to maintain the
heating and natural gas). Firing with wood ning at full output until the set temperature boiler outside the heating season, at least
pellets, wood chips or grain/corn in MULTI- is close to being achieved - then the control one hot water tank (100-300 litres) as well
HEAT can achieve considerable savings in switches over to reduced output and conti- as 1-2 radiators or under-floor heating must
comparison to oil. Such savings depend, nues at this rate. If the boiler temperature be connected (open), but as such no large
amongst other things, on the type of fuel, drops slightly below the set temperature heat storage tank of 1.000-1.500 litres is >^/
purchase prices and the annual efficiency of again, the control will once again switch necessary. Whilst firing at intervals, the use-
the old oil boiler. Furthermore many local over to full output. This control ensures con- ful effect is lower.
governments, and possibly yours, are giving stant heat - almost like an oil-fired furnace. In order to obtain the best possible yield as
grants or subsidies for the installation of With regard to the efficiency of the pre- far as the firing economy, the environment
Multi Heat boilers using renewable energy combustion, the boiler size and adjustment and comfort are concerned, it is important
fuel. of the output ought to be only slightly that the boiler is correctly installed and ad-
greater than the building's requirement. justed.

Some advantages in short


• For economical, environmentally friend-
ly combustion of various fuels such as
wood pellets, grain/corn and wood chips.
• Constant heating gives optimum building
comfort. Very high efficiency: 89-91%.
• Multifunctional digital control provides
simple operation with continuously
variable heat output from 30-100%. The
boiler does not require a storage tank.
• Exposed parts of the combustion cham-
ber are constructed in acid-proof,
stainless steel (AISI316L). Remaining
steel plates exposed to flue gas are 6 mm
thick.
• With automatic shut-off to prevent fuel
hopper burn back.
• Convenient top flue exit location.
• Delivered completely assembled and
ready-mounted with hopper, casing and
control.
• Oxygen control and automated refilling
of hopper available as optional extras.
MULTI-HEAT: Fully automatic stoker boiler with hopper.

For 75 years BAXIA/S - with it's approxi- based on strict requirements for material Reliability of operation, unique firing
mately 200 member Danish workforce - and technical construction design. economy and, not least, consideration of the
has been a pioneer in the development It has always been a part of the company's environment are factors which have been in-
and production of central heating objective that the products from BAXI A/S strumental in placing BAXI A/S as an inter-
boilers. should satisfy the users' requirements nationally recognised supplier of central
BAXI A/S has grown to be Denmark's regarding both the functional quality and heating boilers.
leading producer of central heating systems good taste. Currently, BAXI A/S carries out To maintain its leadership position, BAXI
used to supply the space heating and quality control in accordance with DS/EN A/S constantly looks to develop and
domestic hot water needs of private dwel- ISO-9001, which is an extensive, internatio- improve its products. There is never a
lings. nally recognised standard for quality control compromise of principle, solid quality, high
The production of BAXI A/S products are systems. output or timeless design.
Solid quality Control panel
Flue gas-affected, water-cooled steel This is placed above the doors and is
plates in the interior of the boiler are 6 operated from the front.
mm thick and especially exposed parts Easy to place in the room
of the combustion chamber are of acid- where it is to be set up Cleaning the boiler
free stainless steel. The flue-gas exit is from the top Removing ash and cleaning the fire
of the boiler and can easily be led
tubes can easily be carried out from
to the chimney. The doors are re-
versible and can be opened the front.
towards the left or the right.

MULTI-HEAT
Can be supplied with various sizes of
fuel hoppers (see technical details). The
door for the hopper is reversible so that
it is possible to fill up fuel either from
Wood pellets,
the back, or from the right or left side.
wood chips and
grain/corn
These are renewable, environmentally
friendly, inexpensive and often
domestic fuels which can replace
imported, more expensive and environ-
MULTI-HEAT
mentally straining fossil fuels (oil). A boiler for the future.
When firing with wood chips, a stirring
device must be mounted in the hopper,
as shown in the illustration.
Wood chips consist of wood which has been mechanical-
ly chopped to a suitably small size. Fine wood chips
must be used, 15-30 mm, or 5-50 mm with a maximum
water content of 25%.
15 cubic meters of coniferous or soft wood can substitute
approx. 1000 litres of oil. *
11 cubic meters of deciduous or hard wood can substitute
approx. 1000 litres of oil. *

MULTI-HEAT is delivered as an assembled unit. The


hopper is fastened with bolts. The boiler and the hopper
can be separated so that internal transport is made easier.
The gear motor draws or turns the worm conveyor/auger
round and feeds the fuel into the combustion chamber at
the proper rate.
Wood pellets are produced as by-products from the wood
industry, e.g. from chips and sawdust which are pressed
into pellets. 2.2 kilograms of wood pellets can substitute
approx. 1 litre of heating oil.

The stoker boiler is delivered with an electronic control


unit which regulates the flow of fuel and air for the com-
bustion. Continuously variable output can be set from
100% to 30% during continuous operation. When the set
temperature has been achieved, the blower must be
switched off and the control will switch over to firing at The sturdy and steady cover of the fuel hopper closes
intervals. In the interval setting, the fire is maintained by tightly so that burn back is avoided. Grain/corn, for example from fallow fields or set-aside
filling a small quantity of fuel at long intervals into the land (energy crops) can well be used as fuel.
combustion chamber and by connecting the blower 2.5 kilograms of grain/corn can substitute approx. f litre
briefly. of boiler oil.
Furthermore, the control makes it possible to produce di- Grain/corn can form clinker which must be removed
gital readings of the boiler temperature, return tempera- from the combustion chamber as required. The co-
ture and smoke temperature. delivered worm conveyor extension must be fitted in the
event of grain/corn stoking.

BAXI External Feeding Unit. You can obtain maximum


operating comforts and time-saving through installation
of a BAXI External Feeding Unit for wood pellets and
When the covering plate between the boiler and the hop- grain/corn. By means of a gear motor incl. a worm con-
per is removed, it is possible to see the ventilator which veyor in a pipe system the solid fuel is automatically
ensures the air necessary for combustion. Here, it is also conveyed from a silo to the hopper of the boiler, if requi-
possible to see the thermostat valve for the sprinkler red. Please see special leaflet for rurther information.
Behind the heavily insulated doors, it is possible to see which prevents retrograde combustion. Uppermost, it is
the horizontal heat exchange tubes with turbulators or re- possible to see the opening for easy access for cleaning * The calorific values indicated are for guidance only
tarders designed for maximum heat exchange efficiency. the flue chamber. since the comparison is dependent on several condi-
Behind the lowest door, the combustion chamber with tions, such as the composition and water contents of
the ceramic combustion zone can be seen. the bio-fuel.
There is plenty of room for cleaning and removing ash.

VBF hot water tank

Draft stabiliser - extra equipment. Strong wind or a very


high chimney can cause excessive and fluctuating chim-
ney draft. In such cases, the solution is building in a draft
stabiliser, since the best combustion is achieved with a MULTI-HEAT can be installed as shown in this diagram. The separate hot water tank (for example the BAXI type VBF
suitable and stable chimney draft of 1.0-2.5 mm water 150 MK II overleaf) must be connected prior to the shunt valve. By means of correct adjustment, this installation will
column. give the possibility of firing at intervals outside of the firing season. It is possible to install the MULTI-HEAT with either
closed or open expansion.
Technical Data
//
0

o • ©

Seen from the front

Seen from the side

MULTI-HEAT Model 1,5 Model 2,5 Model 4,0


1. Boiler control X X X
9. Smoke pipe branch, external diameter mm 130 150 150
1 0. Hopper door, reversible X X X
18. Flow and expansion inches 1 1 1
19. Return inches 1 1 1
20. Connection of retrograde fire safety sprinkler inches >/2 '/2 '/2
H1 Height mm 1010 1280 1280
H2 Height mm 1165 1475 1475
LI Depth of boiler mm 581 585 700
L2 Measurement mm 197 217 217
L3 Hopper depth mm 497 615 615
L4 Measurement mm 1435 1578 1693
L5 Measurement mm 360 294 403
L6 Measurement mm 125 125 125
L7 Measurement mm 165 248 245
B4 Hopper width, vol. 200 litres mm 504 - -
B4 Hopper width, vol. 350 litres mm 904 - -
B4 Hopper width, vol. 360 litres mm - 600 600
B4 Hopper width, vol. 600 litres mm - 1000 1000
Bl Measurement mm 252 300 300
B2 Measurement mm 252 300 300
B3 Boiler width mm 504 600 600
B5 Measurement mm 215 225 225
Gear motor, effect kW 0,12 0,37 0,37
Blower motor W 90 90 90
Electricity consumption kW 0,3 0,46 0,46
Electricity connection / circuit breaker 3x400 V + zero + earth - 50 Hz / 10 A X X X
Pipe branches for electrical elements (2) inches 2*) 2*) -
*) Extra equipment.
Output Hopper Weight
Type designation Fuel
kW size kg
MULTI-HEAT 1 ,5 - 200 15 200 Wood pellets 340
MULTI-HEAT 1,5 -350 15 350 Wood pellets 400
MULTI-HEAT 2.5 -360 25 360 Wood pellets 530
MULTI-HEAT 2.5 -600 25 600 Wood pellets 600
MULTI-HEAT 2,5 -360 23 360 Grain/corn 530
MULTI-HEAT 2.5 - 600 23 600 Grain/corn 600
MULTI-HEAT 2.5 F- 600 23 600 Wood chips 630
MULTI-HEAT 4.0 -360 43 360 Wood pellets 580
MULTI-HEAT 4.0 - 600 43 600 Wood pellets 650
MULTI-HEAT 4,0 -360 37 360 Grain/corn 580
MULTI-HEAT 4.0 -600 37 600 Grain/corn 650
MULTI-HEAT 4.0 F- 600 37 600 Wood chips 680
* Oxygen control to be ordered separately and mounted at the installation address
Oxygen control for Multi-Heat, please order Baxi-No. 089200
Equipment package:
Complete stoker boiler consisting of boiler, casing
with insulation, fuel hopper, worm conveyor and
gear motor for conveying the fuel, blower, turbo-
lators, ceramic insert, boiler control, micro-switch
for hopper and thermostatic retrograde combustion
cut-out as well as internal electrical installation and
cleaning tools.

Extra accessories:
Pressure vessel set for automatic water sprinkling
Oxygen control for Multi-Heat
Shunt valve
VBF 100-200 MK II wall-hung hot water tank
VBF-S 150-200-333 floor sited hot water tank
Copper spiral for hot water for types 1.5 and 2.5
Cover with 2 inch socket for electrical element
for types 1.5 and 2.5
Draft stabiliser for chimney/boiler flue outlet
Automatic shunt control
External Feeding Unit
Fuel:
Suitable fuels: wood pellets, grain/corn and wood
chips. During combustion of wood chips a stirrer or
agitator must be fitted in the hopper (implementa-
tion F). Model 1.5 is principally developed for Technical data:
firing with wood pellets. If other forms of fuel are
desired, please contact the importer (or the factory). MULTI-HEAT Model 1,5 Model 2,5 Model 4,0
Operating temperature °C 60-85 60-85 60-85
Arrangement conditions: Output (nominal) with wood pellets kW 15 25 43
MULTI-HEAT must be set up in a room with a suf- Output (nominal) with grain/corn kW - 23 37
ficient supply of air. The magnitude of the air- Output (nominal) with wood chips) kW - 23 37
intake must correspond to the inside diameter of the
Output (minimum) with wood pellets kW 4,5 7,5 8
chimney, however at least 0.02 m2.
• The chimney draft must be at least 1.0-2.5 mm Output (minimum) with grain/corn kW - 6,8 9
water column. Output (minimum) with wood chips kW - 6,8 10
• Furthermore, the local building regulations in the Output (stand-by) recommended ** approx. kW 0,5 0,8 1,0
area of the installation must be followed.
• Request, if necessary, further installation and Smoke temperature at nom. output, wood pellets °C 130 170 158
operational guidelines with further information Smoke temperature at nom. output, grain/corn °C - 167 152
from the importer. Smoke temperature at nom. output, wood chips °C - 178 183
Smoke temperature at min. output, wood pellets *** °C 60 80 75
Our assortment of solid fuel boilers also
comprises the following: Smoke temperature at min. output, grain/corn *** °C - 85 80
Smoke temperature at min. output, wood chips °C 85 80
• MB-SOLO MK II (for wood, coal, coke and oil)
• SOLO INNOVA with induced draft (for forest Fuel consumption at nom. output, wood pellets kg/h 3,4 5,7 10
wood products - connected to the storage tank) Fuel consumption at nom. output, grain/corn kg/h - 6,0 11
• DUO PLUS COMPACT, double chamber boiler Fuel consumption at nom. output, wood chips kg/h 7,2 11
(for oil/gas and wood).
Test pressure, boiler bar 4,0 4,0 4.0
Guarantee: DTI-approved fuel types: wood pellets, approx. 8% water X X X
Fully effective guarantee as in accordance with gu- grain/corn (barley and wheat), approx. 15% water - X X
arantee conditions from the importer/dealer. wood chips, approx. 25% water X X
NB: Type MULTI-HEAT is supplied without built-
in hot water supply.
Installation data:
** Least recommended stand-by output whilst
firing at intervals so that the fire can be main- MULTI-HEAT Model 1,5 Model 2,5 Model 4,0
tained. ADepth - total mm 1435 1578 1693
*** This is the minimum smoke temperature BWidth - boiler mm 504 600 600
which is achieved by approval of the mini-
mum output. This smoke temperature is too C Height mm 1165 1475 1475
low for normal operation with ordinary chim- D Width - hopper * mm 504/904 600/1000 600/1000
neys. We consider a smoke temperature of Hopper volume litre 200/350 360/600 360/600
100°C to be the absolute minimum for ordina- Height to smoke pipe branch mm 1110 1455 1455
ry chimneys. We have therefore built in an
alarm on the smoke temperature at 100°C. Smoke pipe branch - external diameter mm 130 150 150
This is to say that if the smoke temperature Weight - empty kg 340-380 530-630 580-680
has been below 100°C for half an hour, the Water contents liter 50 125 150
boiler will stop. This alarm also ensures
against continually filling up with fuel if the Necessary door opening: Width D + 30 mm
fire has gone out.

BAX1
>ATTDN FTRF.WOOD
DISTRIBUTED BY 39B Park Farm Industrial Estate
Buntingford
Hertfordshire SG9 9AZ Smedevej, DK 6880 Tarm
Tlf. +45 97 37 1511 • Fax +45 97 37 24 34
Tel No: 01763 271271 E-mail: baxi@baxi.dk • www.baxi.dk
Fax No: 01763 271270
www.fbcgroup.co.uk
Publ. nr. 10420/0202 BAXI-katalog afsnit 5