SmB-15 Fishing History

May 05
- Cycle control line 10 times. No indication of piston movement (100 ml
hydraulic returns)
- RIH slowly with 1-7/8" sinker bar tagged 162.1mRKB. Tool hung-up
(potential flapper partially open).
- Pressure up control line to 4000 psi, pumping @ 1bpm for 30 min.
Increase pumping to 2 bpm and pull sinker bar weight at 650 lbs - able to free
sinker bar.
- Recommend not to use toolstring with 90o shoulder.

June 05 (Lock-open SCSSV Attempt)


- Suspect control line pressure still not holding (not sure if control line is
connected to SCSSV or SVLN)
- RIH SLOT to TRM-4A SCSSV. Jar down 30 times - no movement of the
valve.
- Observed SITHP drops 300 psi. Pulling weight drops by 70 lbs. POOH.
- Left SLOT in hole.
- 2.75" LIB tagged top of fish (Suspect upper body - item #3 of the SLOT)
@ 159.1 mRKB.

Oct 05 (Fishing SLOT)


- RIH 2.75" OD BDK Releasable Spear w/dummy slips into SLOT upper
body - connected and able to shear pin.
- RIH with 0.95" - 1.06" slip - able to latched on fish. Jar up for 45 minutes.
POOH.
- Found top of releasable spear attached to the tool string. (Refer pic)
- Tagged TOF @ 158.8 mRKB. Need to jar down to release spear.
- Set plug @ SVLN.

Feb 07 (Injectivity Test)


- Attempted to bullhead SW to establish injectivity - fail due to SITHP
increases from 300 psi to 1000 psi at 0.25 bpm for 0.5 bbls.
- Total SW pumped 9.5 bbls. Leak-off rate from 1000 psi to 300 psi in 6
minutes. Reset plug @ SVLN.
SmB-15st1 Forward Plan Discussion

Attendees:

1) Iman Sunhaji EMEPMI


2) Dennie Stephen Masulah EMEPMI
3) Sies Hussain EMEPMI
4) Roziman Ab. Rahman CAMCO SLB
5) Yunus Sudiana GEOWELL
6) Roman Kucbel BAKER HUGHES
7) Zamani Ab. Rani BAKER HUGHES

Venue: 28.85 (2.00 pm - 4.00 pm)

A) Condition of SLOT @ TRM-4A SCSSV

• Suspect lower no-go dogs (Item 4) and upper no-go dogs (Item 26) are in
expanded position and might be wedged inside the polished bore.
• Top rope socket/ top sub of the SLOT was backed-off / has been parted
during lock-open job.
Possibility of hydraulic ram / cylinder rod (Item 2) is dropped in hole due to
aggressive jarring action during the lock-open job. Bottom section (Item 21,
22, 25, and 23) is possible dropped in hole as well.
-
- B) Condition of the BDK Releasable Spear inside SLOT
-
• Top sub was retrieved and spear is attached inside the SLOT causing the
upper no-go dogs (Item 26) to be expanded.
• Need to have a cylinder rod to be jarred down on the top of the BDK upper
portion to release spear.
• Once spear is released, to RIH overshot to fish out the whole BDK
Releasable Spear.
-
-
- OPTIONS AVAILABLE
A) To attempt to kill D-90 sand from the annulus (through gas lift valves).
If D-90 can be killed from the annulus, proceed with blind back-off tubing
during workover. If well cannot be killed through annulus, proceed to Step B.
- (Tentatively 2nd week of April) - EMEPMI
-
B) To run in hole wireline fishing tools to retrieve the spear (To plan job by
2nd week of April) - Geowell to submit proposal.
a. To RIH cylindrical rod/6 ft length sinker bar to jar down on the spear
to release into locked position.
b. To fish BDK spear with overshot -> Use hard material / releasable
overshot.
- Will be manufactured based on the size of the top body of the
BDK spear. (Geowell/Asep)
- Once spear is retrieved, test the tubing injectivity.
c. If no injectivity, run in hole long rod (OD = hydraulic ram inside
SLOT) to tag top of hydraulic ram inside the SLOT.
d. Mill SLOT up to upper no-go dogs (Item 26). [Run burn shoe may
not be feasible due to limited clearance from tubing ID to OD of SLOT].
Then RIH overshot to retrieve SLOT (evaluating COS) - (Baker) Targeted
first week of May.
-
C) To proceed with milling overall SLOT, will need to consider cementing
top of fish (unlikely due to extended duration required based on hard
materials).
-
D) To go with workover rig and to perform straight pull on the tubing (36
kips). D-90 estimated BHP = 900 psi.