PLANILHA DE CÁLCULO DO DIMENSIONAMENTO DA DRENAGEM DA RUA PONTA GROSSA E RUA LAURA LOPES LATUF EM SÃO JOSÉ
DOS PINHAIS
PV3 PV4 01+0,00 00+5,00 0.0019 0.0019 15.00 0.0150 0.20 0.20 0.01333 0.82864 10.00000 5 2.2816 0.80 0.06 3.650 0.10 66.50 2.74 0.13 0.34 0.40
LANÇAMENTO NA RUA CASTRO EM TRAVESSIA EXISTENTE 0.500 0.15 66.50 1.33 0.28 0.38 0.60
CL7 PV6 04+10,00 06+05,00 0.0053 0.0053 36.50 0.0365 0.30 0.30 0.00822 1.97985 10.00000 5 2.2816 0.80 0.16 1.990 0.10 66.50 2.02 0.13 0.25 0.40
LANÇAMENTO EM EMISSÁRIO FINAL EXISTENTE NA RUA RUBENS HUERGO
DIMENSIONAMENTO MÍNIMO NECESSÁRIO P/EMISSÁRIO EXISTENTE NA RUA RUBENS HUERGO 1.41 1.800 0.20 66.50 3.05 0.50 1.53 0.80
CL8 PV9 01+10,00 00+05,00 0.0014 0.0014 25.50 0.0255 0.70 0.70 0.02745 0.94420 10.00000 5 2.2816 0.80 0.04 1.620 0.10 66.50 1.82 0.13 0.23 0.40
LANÇAMENTO EM EMISSÁRIO FINAL EXISTENTE NA RUA PONTA GROSSA
PV12 CL13 10+10,00 08+10,00 0.0033 0.0033 49.00 0.0490 0.04 0.04 0.00082 6.04308 10.00000 5 2.2816 0.80 0.10 0.170 0.15 66.50 0.77 0.28 0.22 0.60
CL13 CL14 08+10,00 07+00,00 0.0033 0.0066 30.00 0.0790 0.03 0.07 0.00089 8.45807 10.00000 5 2.2816 0.80 0.20 0.170 0.15 66.50 0.77 0.28 0.22 0.60
CL14 PV16 07+00,00 04+16,00 0.0032 0.0098 43.50 0.1225 0.03 0.10 0.00082 12.23692 12.23692 5 2.1288 0.80 0.28 0.120 0.20 66.50 0.79 0.50 0.40 0.80
LANÇAMENTO EM EMISSÁRIO FINAL NÃO EXISTENTE NA RUA FROF.MARIA LENITA DUNA (FAZER TRAVESSIA) 0.500 0.20 66.50 1.61 0.50 0.81 0.80
PV12 CL13 10+10,00 08+10,00 0.0033 0.0033 49.00 0.0490 0.04 0.04 0.00082 6.04308 10.00000 5 2.2816 0.80 0.10 0.170 0.15 66.50 0.77 0.28 0.22 0.60
CL13 PVQ14 08+10,00 07+00,00 0.0033 0.0066 30.00 0.0790 0.03 0.07 0.00089 8.45807 10.00000 5 2.2816 0.80 0.20 0.170 0.15 66.50 0.77 0.28 0.22 0.60
PVQ14 PV16 07+00,00 04+16,50 0.0032 0.0098 43.50 0.1225 0.03 0.10 0.00082 12.23692 12.23692 5 2.1288 0.80 0.28 0.120 0.20 66.50 0.79 0.50 0.40 0.80
LANÇAMENTO EM EMISSÁRIO FINAL NÃO EXISTENTE NA RUA FROF.MARIA LENITA DUNA (FAZER TRAVESSIA) 0.500 0.20 66.50 1.61 0.50 0.81 0.80
PV18 CL19 04+00,00 03+00,00 0.0020 0.0020 36.50 0.0365 0.04 0.04 0.00110 4.30061 10.00000 5 2.2816 0.80 0.06 0.170 0.15 66.50 0.77 0.28 0.22 0.60
CL19 CL20 03+00,00 01+10,00 0.0017 0.0037 30.00 0.0665 0.03 0.07 0.00105 6.93220 10.00000 5 2.2816 0.80 0.11 0.170 0.15 66.50 0.77 0.28 0.22 0.60
CL20 PV22 01+10,00 00+04,50 0.0020 0.0057 25.50 0.0920 0.03 0.10 0.00109 8.79123 10.00000 5 2.2816 0.80 0.17 0.170 0.15 66.50 0.77 0.28 0.22 0.60
LANÇAMENTO EM EMISSÁRIO FINAL NÃO EXISTENTE NA RUA ALCIONEI R.DA ROSA 0.500 0.15 66.50 1.33 0.28 0.38 0.60
* Veloc.mínima = 0,75m/s -- Veloc.máxima = 5,00m/s
GUATUPÊ Miguel Grassi Entre Avenida Rui Barbosa até o final da rua
GUATUPÊ Sleyman Fayad Entre Salomão M. Nasser até o final
GR Consultoria e
Planejamento Urbano
PLANILHA DE CÁLCULO DO DIMENSIONAMENTO DA DRENAGEM DA RUA JOÃO BATISTA DE CAMARGO EM SÃO JOSÉ DOS PINHAIS
CL8 PV9 22+10,00 18+08,00 0.0063 0.0063 112.00 0.1120 3.00 3.00 0.02679 2.97872 10.00000 5 2.2816 0.80 0.19 4.150 0.10 66.50 2.92 0.13 0.37 0.40
CL13 PVQ11 13+10,00 17+00,00 0.0040 0.0040 80.00 0.0800 0.30 0.30 0.00375 4.90063 10.00000 5 2.2816 0.80 0.12 0.820 0.10 66.50 1.30 0.13 0.16 0.40
PVQ11 PV9 17+00,00 18+08,00 0.0026 0.0066 28.00 0.1080 0.10 0.40 0.00370 6.20421 10.00000 5 2.2816 0.80 0.20 0.350 0.15 66.50 1.11 0.28 0.31 0.60
LANÇAMENTO NA RUA CLÁUDIO PEREIRA DA CRUZ EM TUBULAÇÃO EXISTENTE 0.39 0.500 0.20 66.50 1.61 0.50 0.81 0.80
PV16 CL15 10+00,00 12+00,00 0.0040 0.0040 80.00 0.0800 2.40 2.40 0.03000 2.20071 10.00000 5 2.2816 0.80 0.12 4.940 0.10 66.50 3.18 0.13 0.40 0.40
CL15 PV14 12+00,00 13+05,50 0.0021 0.0061 25.00 0.1050 0.35 2.75 0.02619 2.85894 10.00000 5 2.2816 0.80 0.19 0.820 0.15 66.50 1.70 0.28 0.48 0.60
LANÇAMENTO NA RUA ALFREDO M. FILHO EM TUBULAÇÃO EXISTENTE
PV20 CL19 03+10,00 05+00,00 0.0030 0.0030 50.00 0.0500 0.50 0.50 0.01000 2.33928 10.00000 5 2.2816 0.80 0.09 0.350 0.10 66.50 0.85 0.13 0.11 0.40
CL19 PV17 05+00,00 07+04,50 0.0030 0.0060 44.50 0.0945 0.25 0.75 0.00794 4.17446 10.00000 5 2.2816 0.80 0.18 0.350 0.15 66.50 1.11 0.28 0.31 0.60
LANÇAMENTO NA RUA ELZA S.CORDEIRO EM EMISSÁRIO FINAL NÃO EXISTENTE (TRAVESSIA) 1.000 0.15 66.50 1.88 0.28 0.53 0.60
AC2 PV2 03+00,00 04+10,00 0.0018 0.0018 45.00 0.0450 0.70 0.70 0.01556 1.81959 10.00000 5 2.2816 0.80 0.05
PV2 CL3 04+10,00 07+10,00 0.0050 0.0068 60.00 0.1050 1.20 1.90 0.01810 3.29631 10.00000 5 2.2816 0.80 0.21 2.700 0.10 66.50 2.35 0.13 0.30 0.40
CL3 CL4 07+10,00 11+00,00 0.0042 0.0110 50.00 0.1550 0.40 2.30 0.01484 4.80223 10.00000 5 2.2816 0.80 0.34 0.500 0.15 66.50 1.33 0.28 0.38 0.60
CL4 PV5 11+00,00 13+00,00 0.0043 0.0153 40.00 0.1950 2.00 4.30 0.02205 4.92016 10.00000 5 2.2816 0.80 0.47 5.190 0.15 66.50 4.28 0.28 1.21 0.60
PV5 CL6 13+00,00 16+05,00 0.0025 0.0178 70.00 0.2650 1.20 5.50 0.02075 6.37800 10.00000 5 2.2816 0.80 0.54 1.830 0.15 66.50 2.54 0.28 0.72 0.60
CL6 CL7 16+05,00 17+15,00 0.0025 0.0203 25.00 0.2900 1.30 6.80 0.02345 6.52272 10.00000 5 2.2816 0.80 0.62 3.590 0.15 66.50 3.56 0.28 1.01 0.60
CL7 PV8 17+15,00 21+05,00 0.0048 0.0252 70.00 0.3600 1.50 8.30 0.02306 7.75460 10.00000 5 2.2816 0.80 0.77 2.340 0.15 66.50 2.87 0.28 0.81 0.60
PV8 CL9 21+05,00 24+00,00 0.0054 0.0306 55.00 0.4150 1.40 9.70 0.02337 8.60624 10.00000 5 2.2816 0.80 0.93 3.200 0.15 66.50 3.36 0.28 0.95 0.60
CL9 PV11 24+00,00 29+10,00 0.0050 0.0356 110.00 0.5250 6.65 16.35 0.03114 9.23537 10.00000 5 2.2816 0.80 1.08 6.070 0.15 66.50 4.63 0.28 1.31 0.60
PV11 CL12 29+10,00 31+10,00 0.0050 0.0406 40.00 0.5650 0.96 17.31 0.03064 9.83437 10.00000 5 2.2816 0.80 1.23 1.200 0.20 66.50 2.49 0.50 1.25 0.80
CL12 PV14 31+10,00 37+00,00 0.0082 0.0388 110.00 0.5250 3.70 13.40 0.02552 9.97065 10.00000 5 2.2816 0.80 1.18 3.800 0.20 66.50 4.43 0.50 2.23 0.80
PV14 DISSIP 37+00,00 37+05,00 LANÇAMENTO NO CÓRREGO COM INSTALAÇÃO DE DISSIPADOR PARA TUBO D=0,80M 2.000 0.20 66.50 3.22 0.50 1.62 0.80
AC2 PV7 03+00,00 0.0264 0.0264 344.74 0.3447 1.60 1.60 0.00464 13.90246 13.90246 5 2.0269 0.80 0.71
PV7 ALA 03+00,00 LANÇAMENTO NO CÓRREGO (INCLUSIVE TRAVESSIA) 0.71 2.000 0.15 66.50 2.65 0.28 0.75 0.60
TRECHO COTA TALVEGUE ÁREA A.C A.C EXTEN- L(ac) H (m) d tc(calc.) tc(adotado) T i Cm Q I P1 P2 Rh 1/η η1 η2 V* S Q B b h f* Ø
(mont.) (jus.) (mont.) (jus.) (km2) acum. ÇÃO (m) (Km) trecho acum (m/m) (min) (min) (anos) (mm/min) (m3/s) (%) (m) (m) (m) * parede fundo (m/s) (m2) (m3/s) (m) (m) (m) (m) (m)
03+00,00LE 05+10,00LE 915.900 911.800 0.0079 0.01 0.01 185.00 0.1850 4.10 4.10 ### 4.71559 10.00000 25 3.2353 0.80 0.34 6.150 0.600 0.707 0.16 66.67 0.015 0.015 4.92 0.21 1.05 1.10 0.60 0.25 0.05
05+10,00LE 09+05,00LE 1.520 0.600 0.707 0.16 66.67 0.015 0.015 2.45 0.21 0.52 1.10 0.60 0.25 0.05
03+00,00LD 05+10,00LD 915.900 911.800 0.0086 0.01 0.01 185.00 0.1850 4.10 4.10 ### 4.71559 10.00000 25 3.2353 0.80 0.37 6.150 0.600 0.707 0.16 66.67 0.015 0.015 4.92 0.21 1.05 1.10 0.60 0.25 0.05
05+10,00LD 09+05,00LD 1.520 0.600 0.707 0.16 66.67 0.015 0.015 2.45 0.21 0.52 1.10 0.60 0.25 0.05
10+10,00LE 09+05,00LE 911.900 911.800 0.0023 0.00 0.00 25.00 0.0250 0.10 0.10 ### 1.95207 10.00000 25 3.2353 0.80 0.10 1.530 0.600 0.707 0.16 66.67 0.015 0.015 2.46 0.21 0.52 1.10 0.60 0.25 0.05
10+10,00LD 09+05,00LD 911.900 911.800 0.0019 0.00 0.00 25.00 0.0250 0.10 0.10 ### 1.95207 10.00000 25 3.2353 0.80 0.08 1.530 0.600 0.707 0.16 66.67 0.015 0.015 2.46 0.21 0.52 1.10 0.60 0.25 0.05
09+05,00LD 09+05,00LE BUEIRO DE GREIDE COLETOR CC3 E CONDUZIDO ATÉ CC4 0.45 0.500 0.23 66.67 0.015 1.78 0.49 0.87 0.80
EMISSÁRIO FINAL COLETOR CC3 E CC4, CONDUZIDO ATÉ BB3 C/ LANÇAM. VALA A CEU ABERTO 0.89 1.000 0.23 66.67 0.015 2.51 0.49 1.23 0.80
0.350 0.800 2.121 0.40 28.57 0.035 0.035 0.91 1.16 1.06 2.30 0.80 0.75 0.15
11+10,00LE 14+00,00LE 911.900 909.400 0.0027 0.00 0.00 60.00 0.0600 2.50 2.50 ### 1.55393 10.00000 25 3.2353 0.80 0.12 6.000 0.600 0.707 0.16 66.67 0.015 0.015 4.86 0.21 1.03 1.10 0.60 0.25 0.05
14+00,00LE 17+08,90LE 909.400 905.000 0.0035 0.00 0.00 68.90 0.1289 4.40 6.90 ### 2.54249 10.00000 25 3.2353 0.80 0.15 6.000 0.600 0.707 0.16 66.67 0.015 0.015 4.86 0.21 1.03 1.10 0.60 0.25 0.05
11+10,00LD 14+00,00LD 911.900 909.400 0.0026 0.00 0.00 60.00 0.0600 2.50 2.50 ### 1.55393 10.00000 25 3.2353 0.80 0.11 6.000 0.600 0.707 0.16 66.67 0.015 0.015 4.86 0.21 1.03 1.10 0.60 0.25 0.05
14+00,00LD 17+08,90LD 909.400 905.000 0.0034 0.00 0.00 68.90 0.1289 4.40 6.90 ### 2.54249 10.00000 25 3.2353 0.80 0.15 6.000 0.600 0.707 0.16 66.67 0.015 0.015 4.86 0.21 1.03 1.10 0.60 0.25 0.05
17+08,90LE 17+08,90LD BUEIRO DE GREIDE COLETOR CC4 E CONDUZIDO ATÉ CC5 0.15 0.500 0.23 66.67 0.015 1.78 0.49 0.87 0.80
0.320 0.800 2.121 0.40 28.57 0.035 0.035 0.87 1.16 1.02 2.30 0.80 0.75 0.15
* Veloc.mínima = 0,75m/s -- Veloc.máxima = 2,00m/s (TERRA); =2,5m/s (GABIÃO); =3,0m/s (PEDRA ARGAMASSADA); =5,00m/s (CONCRETO)
OBS:
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm)
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm)
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm)
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm)
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm)
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm)
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm) PREVER CAIXA DE
QUEDA
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm)
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm) PREVER CAIXA DE
QUEDA
CANALETA TRAPEZOIDAL(bxBxh)
(60x120x30cm)
PROBLEMAS ENCONTRADOS