Escolar Documentos
Profissional Documentos
Cultura Documentos
Notice
The purchased products, services and features are stipulated by the contract made between Huawei
and the customer. All or part of the products, services and features described in this document may
not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all
statements, information, and recommendations in this document are provided "AS IS" without
warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in
the preparation of this document to ensure accuracy of the contents, but all statements, information,
and recommendations in this document do not constitute a warranty of any kind, express or implied.
Address: Cra 68 B # 24B-10 Plaza Claro, Tower 2, 10th floor, Bogotá - Colombia
Website: http://www.huawei.com
Email: support@huawei.com
2
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Contenido
Procedimientos adicionales…………………………………………………………………..40
3
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
1. Introducción.
Este documento explica el procedimiento detallado para realizar la configuración y comisionamiento
de los equipos de la serie OptiX RTN380 versión V100R019 usando el software Web LCT.
Específicamente detalla el proceso para el comisionamiento requerido por WOM en su proyecto de
instalación de redes de transmisión.
2. Preparación.
El software compartido corresponde a una carpeta comprimida que debe alojarse y descomprimirse
en la raíz de una de las particiones del computador.
4
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Debe confirmarse la existencia de la carpeta jre, conf, bin, engineering, etc, logs, var weblct,
web_app; además de los ejecutables startweblct y stopweblct. También debe confirmarse la
existencia del ejecutable dc_StandAlone dentro del directorio weblct:
En caso que no existan las carpetas y ejecutables enunciados será necesario descomprimir
nuevamente el archivo comprimido.
Confirmar que el explorador corresponde a Internet Explorer 11, varias de las funcionalidades como
la creación de puertos, creación de servicios, entre otras, no son ejecutables en Chrome:
5
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
6
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
1.
2.
5.
4
6. .
7.
Una vez creado el equipo hay que loggearlo, para ello su “communication status” debe estar como
“Normal”. De no ser así se debe verificar la conexión física al equipo, la IP iniciada al computador o
que haya sido creado como SSL Gateway. Posteriormente se inicia el usuario “lct” o “root” ambos
con password: Changeme_123
7
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Una vez esto un doble click (o hacer click derecho sobre él y elegir la opción “NE Explorer”) abre
el equipo en la ventana Slot Layout, la ODU tiene que aparecer en el slot layout en color verde oscuro
lo que indica su correcto reconocimiento:
Alarmas
Slot Layout
Funciones
3. Comisionamiento
3.1 Atributos de identificación.
Se procede a dar al radio un nombre y ID para su identificación, esto se hace en el menú
“Configuration > NE Attributes del árbol de funciones.
8
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Estos IDs, nombres y parámetros de acuerdo al requerimiento (tabla) suministrado por WOM:
Una advertencia indicará que una vez cambiados estos parámetros el NE se “desloggeará” y será
necesario volver a loggear. Dar click en “Yes”
10
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Se configura ancho de banda y modulación que son valores consignados en la tabla de Excel y
dependiendo si al sitio le corresponde frecuencias altas o frecuencias bajas:
11
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
- XPIC: Deshabilitado a menos que la OT lo indique
- Link ID: De acuerdo con la solicitud de la OT
- IF Channel Bandwidth: De acuerdo con la solicitud de la OT
- Modulation Mode: De acuerdo a la solicitud de la OT
- AMAC Status: De acuerdo a la OT
- TX Frecuency (MHz): De acuerdo a la solicitud de la OT (Tener en cuenta el rango de
frecuencias de las ODU mostradas en las marquillas del equipo)
- T/R Spacing (MHz): De acuerdo a la solicitud de la OT
- TX Power (dBm): De acuerdo a la solicitud de la OT
- TX Status: Unmute
- Antenna Polarization: V
Tener en cuenta que una vez exista comunicación con el lado remoto. La variación de uno de los
parámetros en un solo lado del enlace. Causará la pérdida de conexión entre los mismos. Por tanto, si
usted se encuentra en el sitio A, debe asegurarse que el cambio se realice primero en el radio remoto
(Sitio B).
Algunas sugerencias:
A continuación, algunas sugerencias que no son requerimientos necesarios para apuntamiento, pero
pueden ayudarles. Algunos de estos apartes y varios adicionales los encontrarán en las guías de
instalación del equipo:
1) Una vez se configuren las opciones en ambos radios, se procede con el apuntamiento de las
antenas para obtener el nivel de potencia RX solicitado. Se recomienda apuntar con la
modulación adaptativa (AM) deshabilitada. Con modulación baja, QPSK por ejemplo; y la
máxima potencia de transmisión que permita dicha modulación.
12
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
confirmado éste nivel de recepción se puede proceder a cambiar el estado de TX Status a
“Unmute”.
13
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Luego de obtener niveles es posible ver la configuración del radio remoto haciendo click en el botón
“Get Links”.
Por defecto, todos los puertos del radio vienen habilitados y por ende con alarma de desconexión. Por
tanto, primero se pueden deshabilitar los que no se van a usar y dejar habilitado el puerto COMBO 1
que es el que corresponde al servicio. Esto seleccionándolos y dándoles clic derecho sobre la columna
“Port enabled”:
14
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
En caso que luego de aplicada la configuración el radio no tome el cambio a 1000M Full Duplex. Es
necesario borrar el puerto y volverlo a crear:
Para ello vamos al Slot Layout y damos click derecho sobre la única tarjeta del radio. Abrimos el Path
view de la tarjeta, damos click derecho sobre el puerto COMBO 1 y borramos:
15
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
1) Tiene creado un servicio (Poco probable si el equipo no ha sido precomisionado). En ese caso hay
que ir a borrar el servicio:
2) Tiene asociada una política de calidad de servicio. En ese caso hay que desasociarla:
16
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
2
..
4
1 .
5
.
.
3
6. ..
Una vez borrado el puerto se vuelve a crear. Esto dando click derecho en el espacio en azul de la
ventana emergente y dando click en add port
Vamos a la función de creación del servicio (1). (2) Y dejamos solo seleccionado el puerto COMBO
1 y el puerto IF para la crosconexión. (3) Se inicializa el ID de servicio:1. El nombre de servicio como
les indique la nomenclatura. Tag Type se inicializa como Tag Transparent. L2 protocol Control se
17
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
inicializa como Not Transparent. Self Learning MAC en Enable. Se garantiza que el puerto COMBO
1 quede en Enabled y se aplican los cambios
18
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
2
4
3
1
5
La plantilla de alarmas que se tendrá en cuenta es la que viene por defecto. La única alarma que debe
quedar en los equipos es:
19
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
La alarma refiere al cambio de contraseña al usuario lct para ingreso al radio. Huawei recomienda
NO hacer el cambio de la contraseña para evitar problemas en la operación y mantenimiento de los
equipos. De manera que es la única alarma que Huawei puede autorizar para suprimir:
Alarmas de propagación:
Deben tratarse de acuerdo con la descripción de cada una y de acuerdo a la configuración y diseño
del enlace.
20
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Por defecto el uso horario de los defectos viene de Beijín, entonces hay que cambiarlo a Bogotá.
Para sincronizar el equipo con la hora local, en Configuration > NE Time Localization” escoger la
zona: Bogotá, Colombia como se muestra en la imagen a continuación.:
3
1
Además, para que el radio sincronice con el gestor NCE debemos indicarle: cambiando de NULL a
NM y aplicando el cambio. Adicionalmente, en la opción Configuration > NE Time syncronization
y elegir como Synchronous Mode NM.
Cambial de NULL a NM
4. Carga de la licencia.
21
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
El ESN corresponde al serial de los equipos y puede obtenerse de la placa del equipo:
También por software en el menú Report >Board Information Report del Web LCT.
Una vez descargadas las licencias tienen la siguiente estructura. Pueden confirmar que el serial es
abriéndolas (Nota: ¡solo confirmar, si modifican algo la dañan!):
22
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Cuando se va a ingresar a un radio por primera vez mediante el DC Stand Alone, el password que se
debe ingresar es “Changeme_123”. Luego de ingresar este password y el código de verificación, el
programa DC Stand Alone solicitará cambiar de password, por lo que se debe registrar un nuevo
password que queda almacenado para los próximos ingresos al DC Stand Alone (ejemplo de
password: Changeme_1234 o Huawei_123). Se recomienda no olvidar el password porque de ser así
se requerirá volver a iniciar desde la descompresión del programa. Una vez esto la interfaz debe ser
igual a la mostrada a continuación:
23
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Entonces vamos a confirmar esa información: vamos al menú System> FTP Settings y se confirma
que la configuración es single NIC (única IP) y que la IP por la que vamos a conectar es la IP que le
pusimos al puerto del computador. Se aplican los cambios.
24
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Si lo guardaron en la partición D del computador se pone “D:”. el usuario para la transferencia de
archivos con el protocolo ftp es ftpuser y su contraseña es Changeme_123. Dar OK a los cambios y
asegurarse que queden aplicados.
4.3 Creación de los equipos en el DC Stand Alone.
NE_Explorer > Create NE: Con la información de Extended ID, ID, IP de Gateway mostradas en
el WEB LCT es posible crear los radios en el datacenter:
El usuario con permisos para hacer la carga es el usuario szhw y el password es Changeme_123.
Dar click en create NE. El software avisa cuando quede creado:
25
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Cerrar esa ventana de creación. El radio aparecerá en la ventana principal del DC:
Abrir la ventana NE License Management:
26
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
27
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Se da click en License information query para ver la licencia actual del radio:
28
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
29
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
30
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
31
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
32
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Buscar el directorio en el que tiene guardada la licencia, filtrar por tipo de archivo XML y
seleccionarla
33
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
34
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
35
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
36
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
Esta información también se puede validar a través del WEB LCT en el menú
Configuration>License Management.
37
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
El usuario con permisos para hacer la carga es el usuario szhw y el password es Changeme_123.
Dar click en create NE. El software avisa cuando quede creado:
39
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co.
Manual de configuración y comisionamiento de equipos OptiX RTN 380AX Proyecto WOM
5.3 Generación del back up.
Cerrar esa ventana de creación. El radio aparecerá en la ventana principal del DC. Se selecciona el
radio al que se va a descargar el Back up. Click derecho> back up:
Y cuando llegue la barra de progreso a 100% abrá terminado de generarse. Quedará guardado en el
repositorio de la herramienta. Solo deben buscar que corresponda al radio que acaban de comisionar