Você está na página 1de 25

Introduction to

Testing Services
© Schlumberger 2003
Schlumberger
225 Schlumberger Drive
Sugar Land, Texas 77478
All rights reserved. No part of this book may be reproduced,
stored in a retrieval system, or transcribed in any form or
by any means, electronic or mechanical, including photo-
copying and recording, without prior written permission
of the publisher.
SMP-7086-1
This book contains excerpts from the Schlumberger publication
Modern Reservoir Testing (SMP-7055). © Schlumberger 1994

An asterisk (*) is used throughout this document to denote a mark of Schlumberger.


Other trademarks or registered trademarks and their respective owners
are listed in “Other Marks.”
Contents

Book 1 Introduction to Testing Services


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Productivity well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Descriptive well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Test design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Marks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Book 2 Downhole Testing Services


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Schlumberger Reservoir Completions Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Flopetrol Johnston–Schlumberger downhole tools history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Seal Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Downhole environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Recommended elastomer compounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Typical Downhole Test String Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Packers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FlexPac system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FlexPac packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
FlexPac hold-down tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
PosiTest packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Long-stroke PosiTest packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Compression-set PosiTest packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Positrieve packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
IRIS Pulse-Operated Test System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Benefits of the IRIS system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Flexible command system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
IRIS dual-valve tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Pressure Controlled Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
PCT valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Hold-open module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
PORT Pressure Operated Reference Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Formation Protector Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Hydrostatic reference tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Single-shot hydrostatic overpressure reverse valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Single-shot hydrostatic overpressure reverse valve (internal/external) . . . . . . . . . . . . . . . . . 44
Multiple-opening, internally operated reversing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Multicycle circulating valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Multicycle circulating valve with lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Pump-through flapper safety valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Introduction to Testing Services ■ Contents iii


Tubing fill/test valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Tubing test valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Single-ball safety valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Pipe tester valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Pump-through safety valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Slip joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Slip joint and TCP gun correlation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Depth control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Jar tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Safety joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Dual-Action Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Fullbore Annular Sample Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
DST String Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
10k IRIS string with DataLatch recorder and TCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
10k IRIS string for shoot and pull . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
IRIS big-bore string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
10k PCT string with DataLatch recorder and TCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
15k PCT HPHT string with TCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
17.5k extreme HPHT string with single-shot tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
17.5k ultra HPHT string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
15k slimhole PCT string with TCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Tapered string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
10k PERFPAC string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

Book 3A Safety Systems


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Riser Sealing Mandrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SenTREE 3 Test Tree System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SenTREE 3 components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Valve assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Latch assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Retainer valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Spanner joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Subsea Control Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Disconnect times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Standard system features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Deep-sea hydraulic system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Deep-sea electrohydraulic system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Drift-off analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Subsea pressure and temperature carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Lubricator Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
E-Z Valve Retrievable Well Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Book 3B Well Testing Services


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Surface testing equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Standard set of equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Equipment layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

iv
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Classified zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Zone 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Zone 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Zone 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Clean zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety standards for equipment layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
H2S service requirements and safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operation guidance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Equipment safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Heat radiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Advanced Well Test Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
General standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Well test design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Equipment safety barriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Surface safety systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Emergency shutdown system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Surface safety valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
21⁄8-in. lightweight flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
21⁄4-in. flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
31⁄8- and 31⁄16-in. flowheads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
61⁄8-in. flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Data Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Sand-Handling Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Dual-pot sand filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Sand separator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Cyclonic desander . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Choke Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Heater types and applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Hydrate prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Viscosity reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Emulsion breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Steam-heat exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Indirect-fired heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Plate-steam exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Test Separator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Separator vessel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Type N test separator (48 in. × 12.5 ft, 1440 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Horizontal test separator (42 in. × 10 ft, 1440 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Type G test separator (42 in. × 15 ft, 720 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Vertical gas separator (2200 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Oil and Gas Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Oil manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Gas manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Surge tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

Introduction to Testing Services ■ Contents v


Atmospheric gauge tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Transfer Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Centrifugal transfer pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Screw-type transfer pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Gear-type transfer pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Oil Burners and Booms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Benefits and features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
EverGreen burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Green Dragon high-efficiency burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Mud burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Burner boom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Standard burner boom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Heavy-duty burner boom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

Book 4 Data Acquisition Services


Laboratory and Acquisition Cabin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Environmental parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Laboratory area description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Gauge Metrology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Static parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dynamic parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Transient response during temperature variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Transient response during pressure variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dynamic response during pressure and temperature shock . . . . . . . . . . . . . . . . . . . . . . . 12
Multiphase Flowmeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operating envelope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Surface testing acquisition network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
SMART system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
STAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Absolute pressure sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
STPS-A pressure transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
STPS-C/D pressure transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Differential pressure sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Temperature sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Flowmeter pulse sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Enhanced liquid measurement flowmeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Universal Pressure Platform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Gauge requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Reliability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Data quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Flexibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
UPP versatility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
UNIGAGE recorder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

vi
UNIGAGE CQG pressure gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Single-point measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Benefits and features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
UNIGAGE quartz pressure gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Benefits and features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
UNIGAGE H-Sapphire pressure gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Unique construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Test performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
UNIGAGE Sapphire pressure gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Monolithic recorder and sensor section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Test performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
UPP setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Memory guard feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Complete history log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Communication through battery feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Reporting and data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Gauge calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
DataLatch System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
DST gauge adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
DGA with downhole LINC wireline adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
LINC downhole coupler assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
LINC running tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Downhole Shut-In Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Multislickline downhole shut-in tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Explosive-free shut-in tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Book 5 Well Test Interpretation


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Fundamentals of Transient Well Test Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Diffusivity equation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Sidebar: Modeling radial flow to a well . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wellbore storage and skin effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Type curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Changing wellbore storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Control of Downhole Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Downhole shut-in techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Downhole flow rate measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Wellsite Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Interpretation Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Interpretation methodology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Data processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Flow regime identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Sidebar: Derivative computation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Use of type curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Introduction to Testing Services ■ Contents vii


Use of numerical simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Three stages of modeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Model identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Parameter estimation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Results verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Use of downhole flow rate measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Description of the problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Model identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Parameter estimation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Model and parameter verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Gas well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Specialized Test Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Layered reservoir testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Selective inflow performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Transient layered testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Interpretation of layered reservoir testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Horizontal wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Multiple-well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Interference testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Pulse testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Vertical interference testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Measurements while perforating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Impulse testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Closed-chamber DST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Water injection wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Pumping wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Permanent monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Pressure Transient and System Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Appendix: Type Curve Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

Book 6 Large-Bore Subsea Services


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Conventional Christmas tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Horizontal Christmas tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SenTREE* 7 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SenTREE 7 Basic String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Modular configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Lubricator valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Bleedoff valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Retainer valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Helical latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Flapper valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Ball valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

viii
Accessories and Project-Specific Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Saver and crossover sub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Packoff sub and space-out sub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Spacer sub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Ported slick joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Fishing Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Post-shear retrieval tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Post-unlatch retrieval tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Commander* Control Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Commander hydraulic control system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Commander telemetry control and monitoring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Emergency shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Design and philosophy requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Operational philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Shutdown philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Valve position indication philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Subsea accumulator module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Subsea control module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Subsea spanner joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Subsea umbilical cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Subsea-controlled functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Surface control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Introduction to Testing Services ■ Contents ix


Introduction

This first book in the Schlumberger Testing Services set introduces productivity and descriptive
well testing and summarizes test types and design principles. These techniques are the ground-
work for the other books on downhole testing services, safety systems and well testing services,
and data acquisition services. This book also includes marks lists and nomenclature for the set.

Well testing
Tests on oil and gas wells are performed at various stages of well construction, completion and
production. The test objectives at each stage range from simple identification of produced fluids
and determination of reservoir deliverability to the characterization of complex reservoir fea-
tures. Most well tests can be grouped as productivity testing or descriptive testing.
Productivity well tests are conducted to
■ identify produced fluids and determine their respective volume ratios

■ measure reservoir pressure and temperature

■ obtain samples suitable for pressure-volume-temperature (PVT) analysis

■ determine well deliverability

■ evaluate completion efficiency

■ characterize well damage

■ evaluate workover or stimulation treatment.

Descriptive tests seek to


■ evaluate reservoir parameters
■ characterize reservoir heterogenities
■ assess reservoir extent and geometry
■ determine hydraulic communication between wells.
Whatever the objectives, well test data are essential for the analysis, prediction and improve-
ment of reservoir performance. These in turn are vital to optimizing reservoir development and
efficient asset management.
Well testing technology is evolving rapidly. Integration with data from other reservoir-related
disciplines, constant evolution of interactive software for transient analysis, improvements in
downhole sensors and better control of the downhole environment have all significantly increased
the importance and capabilities of well testing.

Productivity well testing


Productivity well testing, the simplest form of testing, provides identification of productive
fluids, collection of representative samples and determination of reservoir deliverability.
Formation fluid samples are used for PVT analysis, which reveals how hydrocarbon phases coex-
ist at different pressures and temperatures. PVT analysis also provides the fluid physical
properties required for well test analysis and fluid flow simulation. Reservoir deliverability is a
key concern for commercial exploitation.

Introduction to Testing Services ■ Introduction 1


Estimating a reservoir’s productivity requires relating flow rates to drawdown pressures.
This can be achieved by flowing the well at several flow rates using different choke sizes (Fig. 1a)
while measuring the stabilized bottomhole pressure and temperature for each corresponding
choke (Fig. 1b).

(a)
q4

q3

q2
Wellhead
flow rate
q1

(b)

p0

p1
Bottomhole
pressure
p2

p3
p4

Time

Figure 1. Relationship between flow rates (q) and drawdown pressures (p).

The plot of flow data versus drawdown pressure is known as the inflow performance relation-
ship (IPR). For monophasic oil conditions, the IPR is a straight line and its intersection with the
vertical axis yields the static reservoir pressure. The inverse of the slope represents the produc-
tivity index of the well. The IPR is governed by properties of the rock-fluid system and near-
wellbore conditions.

2
Examples of IPR curves for low (A) and high (B) productivity are shown in Fig. 2. The steeper
line corresponds to poor productivity, which could be caused either by poor formation flow prop-
erties (low mobility-thickness product) or by damage caused while drilling or completing the well
(high skin factor). For gas wells, IPR curves exhibit a certain curvature (C) caused by extra pres-
sure drops resulting from inertial and turbulent flow effects in the vicinity of the wellbore and
changes of gas properties with pressure. Oil wells that flow below the bubblepoint also display
similar curvature, but this is due to changes in relative permeability created by variations in satu-
ration distributions.

4200

3800

Sandface pressure
3400
(psia)
C

3000
A B

2600
0 20,000 40,000 60,000 80,000
Flow rate at surface conditions (B/D)

Figure 2. Typical inflow performance curves.

Descriptive well testing


Estimation of the formation’s flow capacity, characterization of wellbore damage, and evaluation
of a workover or stimulation treatment all require a transient test because a stabilized test is
unable to provide unique values for mobility-thickness and skin effect. Transient tests are per-
formed by introducing abrupt changes in surface production rates and recording the associated
changes in bottomhole pressure. The pressure disturbance penetrates much farther than in the
near-wellbore region, to such an extent that pressure transient tests have evolved into one of the
most powerful reservoir characterization tools. This form of testing is often called descriptive or
reservoir testing.
Production changes during a transient well test induce pressure disturbances in the wellbore
and surrounding rock. These pressure disturbances extend into the formation and are affected in
various ways by rock features. For example, a pressure disturbance will have difficulty entering a
tight reservoir zone but will pass unhindered through an area of high permeability. It may dimin-
ish or even vanish upon entering a gas cap. Therefore, a record of the wellbore pressure response
over time produces a curve for which the shape is defined by the reservoir’s unique characteristics.

Introduction to Testing Services ■ Introduction 3


Unlocking the information contained in pressure transient curves is the fundamental objective of
well test interpretation. To achieve this objective, analysts display pressure transient data in
three different coordinate systems:
■ log-log (for model recognition of reservoir response)

■ semilog (for parameter computation)

■ Cartesian (for model and parameter verification).

Typical pressure responses that might be observed with different formation characteristics are
shown in Fig. 3. Each plot consists of two curves presented as log-log graphs. The top curve rep-
resents the pressure changes associated with an abrupt production rate perturbation, and the
bottom curve (termed the derivative curve) indicates the rate of pressure change with respect to
time. Its sensitivity to transient features resulting from well and reservoir geometries (which are
too subtle to recognize in the pressure change response) makes the derivative curve the single
most effective interpretation tool. However, it is always viewed together with the pressure change
curve to quantify skin effects that are not recognized in the derivative response alone.

Homogeneous reservoir

Double-porosity reservoir

Pressure – pressure
derivative (psi)

Impermeable boundary

Elapsed time (hr)

Figure 3. Pressure transient log-log plots.

4
Pressure transient curve analysis probably provides more information about reservoir charac-
teristics than any other technique. Horizontal and vertical permeability, formation pressure, well
damage, fracture length, storativity ratio and interporosity flow coefficient are just a few of the
characteristics that can be determined. In addition, pressure transient curves can indicate the
reservoir’s areal extent and boundary geometry. Figure 4 shows the features of outer boundary
effects and the effects of damage removal.
The shape of the pressure transient curve, however, is also affected by the reservoir’s produc-
tion history. Each change in production rate generates a new pressure transient that passes into
the reservoir and merges with the previous pressure effects. The observed pressures at the well-
bore are a result of the superposition of all these pressure changes.
Different types of well tests can be achieved by altering production rates. Whereas a buildup
test is performed by closing a valve (shut-in) on a producing well, a drawdown test is performed
by putting a well into production. Other well tests, such as multirate, multiwell, isochronal and
injection well falloff, are also possible.
Mathematical models are used to simulate the reservoir’s response to production rate
changes. The observed and simulated reservoir responses are compared during well test inter-
pretation to verify the accuracy of the model. For example, by altering model parameters such
as permeability or the distance from the well to a fault, a good match can be reached between
the real and modeled data. The model parameters are then regarded as a good representation of
those of the actual reservoir.
Today’s computer-generated models provide much greater flexibility and improve the accuracy
of the match between real and simulated data. It is now possible to compare an almost unlimited
number of reservoir models with the observed data.

101

100

Before acid buildup


Pressure – pressure
derivative (psi)

10–1

After acid buildup

10–2
10–3 10–2 10–1 100 101 102

Elapsed time (hr)

Figure 4. Outer boundary effects and effects of damage removal in pressure response curves.

Introduction to Testing Services ■ Introduction 5


Test design
Design and implementation of a well testing program can no longer be conducted under standard
or traditional rule-of-thumb guidelines. Increasingly sophisticated reservoir development and
management practices, stringent safety requirements, environmental concerns and a greater
need for cost efficiency require that the entire testing sequence, from program design to data
evaluation, be conducted intelligently. Proper test design, correct handling of surface effluents,
high-performance gauges, flexible downhole tools and perforating systems, wellsite validation
and comprehensive interpretation are key to successful well testing.
The importance of clearly defined objectives and careful planning cannot be overstated.
Design of a well test includes development of a dynamic measurement sequence and selection of
hardware that can acquire data at the wellsite in a cost-effective manner. Test design is best
accomplished in a software environment where interpreted openhole logs, production optimiza-
tion analysis, well perforation and completion design, and reservoir test interpretation modules
are simultaneously accessible to the analyst.
The first step in test design involves dividing the reservoir into vertical zones using openhole
logs and geological data. The types of well or reservoir data that should be collected during the
test are then specified. The data to be collected determine the type of well test to be run (Table 1).

6
Table 1. Summary of Different Test Types
Test Type Measurement Conditions Distinguishing Design
Characteristics Consideration
Flowing Shut-in Pulse Slug
Closed-chamber test † ‡ ‡ Downhole shut-in Chamber and cushion lengths;
valve open/shut sequence

Constant-pressure ‡ ‡ Requires transient flow Flow rate sensitivity


flow test rate measurement

Drillstem test † ‡ Downhole shut-in; Flowing and shut-in sequence/


openhole or cased hole duration

Formation test ‡ ‡ Test conducted on Tool module sizing/selection;


borehole wall; formation pressure sensitivity
fluid sampling

Horizontal well test ‡ ‡ Testing hardware usually Minimize wellbore storage effects;
located in vertical part requires long-duration test
of hole

Impulse test ‡ ‡ Transients initiated by Trade-off between impulse


short-rate impulse duration and pressure sensitivity

Multilayer transient test ‡ ‡ Multirate test; pressure Flow rate/pressure sensitivity; test
and rate measured at sequence; measurement depths
several depths

Multiwell interference test ‡ ‡ † Transient induced in Test duration; pressure sensitivity


active well, measured
in observation well

Pumped-well test ‡ Downhole pressure Downhole pressure sensor versus


measured or computed surface acoustic device
from liquid-level soundings

Stabilized-flow test ‡ Includes isochronal, flow- Time to reach stabilization


after-flow, inflow perfor-
mance, production logs

Step-rate test ‡ Flow test to determine Flowing pressure range must


injection well parting include parting pressure
pressure

Testing while perforating ‡ ‡ ‡ Testing hardware and Underbalance determination


perforation guns on the
same string

Transient rate and ‡ ‡ Downhole measurement Flow rate/pressure sensitivity


pressure test of pressure, flow rate,
temperature and (usually)
density

Vertical interference test † ‡ † Transient induced at one Test duration; pressure sensitivity
depth and measured at
another
† = Under certain conditions
‡ = Commonly conducted

Introduction to Testing Services ■ Introduction 7


Once the type of test is determined, the sequence changes in surface flow rate that should
occur during the test are calculated. The changes in flow rate and their duration should be real-
istic and practical so they generate the expected interpretation patterns in the test data. This is
best achieved by selecting an appropriate reservoir model and simulating the entire test
sequence in advance (Figs. 5 and 6). Test sequence simulation allows exploring the entire range
of possible pressure and flow rate measurements. Simulation also helps identify the types of
sensors capable of measuring the expected ranges. Diagnostic plots of simulated data should be
examined to determine when essential features will appear, such as the end of wellbore storage
effects, duration of infinite-acting radial flow and start of total system response in fissured
systems. The plots can also help anticipate the emergence of external boundary effects, includ-
ing sealed or partially sealed faults and constant-pressure boundaries.
The next step is to generate sensitivity plots to determine the effects of reservoir parameters
on the duration of different flow regimes.
The final step of the test design process is to select the instrumentation and equipment for
data acquisition. Surface and downhole equipment should be versatile to support safe, flexible
operations. Key factors to consider include
■ controlling the downhole environment to minimize wellbore storage

■ using combined perforating and testing techniques to minimize rig time

■ running ultra-high-precision gauges when test objectives call for a detailed reservoir description

■ choosing reliable downhole recorders to ensure that the expected data will be retrieved when
pulling the tools out of hole
■ selecting surface equipment to safely handle expected rates and pressures

■ disposing of produced fluids in an environmentally acceptable manner.

Whatever the test design, it is important to ensure that all data are acquired with the utmost
precision. To do this, it is necessary to have a good understanding of the available hardware
options and any prospective impact on data quality.

8
10,000

8000

Pressure (psia)

6000

4000
0 1 2 3 4
Elapsed time (hr)

Figure 5. Simulated pressure response.

106
Pressure
Derivative
105

104
Pressure – pressure Wellbore
derivative (psi) storage
Limits
103
Radial flow

102
Double-porosity behavior

101
10–4 10–2 100 102 104
Elapsed time (hr)

Figure 6. Test design flow identification plot.

Introduction to Testing Services ■ Introduction 9


Marks

Marks of Schlumberger
Mark Spelled-Out Version or Description
Commander control systems for subsea well control

CQG Crystal Quartz Gauge

DataLatch electrical wireline downhole recorder/transmitter

EverGreen minimal environmental impact well effluent burner

E-Z Tree retrievable well control tree

E-Z Valve retrievable well control valve

Green Dragon high-efficiency burner

HPR Hostile Environment Pressure Recorder

HSD High Shot Density gun system

IRIS Intelligent Remote Implementation System

LINC Latched Inductive Coupling tool

MFE Multiflow Evaluator tool

NODAL production system analysis

PCT Pressure Controlled Tester

PERFPAC sand control method

PhaseTester portable multiphase periodic well testing equipment

PORT Pressure Operated Reference Tool

PosiTest retrievable compression packer

Positrieve retrievable compression packer with hold-down section

QUANTUM gravel-pack packer family

RFT Repeat Formation Tester

Sandec sand-flow detection equipment

Sapphire pressure gauge

SenTREE subsea well control systems

SMART Schlumberger Modular Acquisition Recording Terminal

UNIGAGE pressure gauge system

Vx multiphase well testing technology

Introduction to Testing Services ■ Marks 11


Other Marks
Mark Company
Aflas® Registered trademark of Asahi Glass Co., Ltd.

Barton® Registered trademark of Barton Instrument Systems, LLC

Daniel® Registered trademark of Daniel Industries, Inc.

Floco® Registered trademark of Barton Instrument Systems, LLC

HASTELLOY® Registered trademark of Haynes International, Inc.

HP® Registered trademark of Hewlett-Packard Company

Kimray® Registered trademark of Kimray, Inc.

Lee Jeva® Registered trademark of Lee Company

Quartzdyne® Registered trademark of Quartzdyne Inc.

Ranarex® Registered trademark of EG&G Chandler Engineering Company

Rotron™ Trademark of Ametek, Inc.

Transaqua® Registered trademark of Castrol Limited

Unix® Registered trademark of The Open Group

Viton® Registered trademark of DuPont Dow Elastomers L.L.C.

Windows® Registered trademark of Microsoft Corporation

Windows NT® Registered trademark of Microsoft Corporation

12
Nomenclature

A area CaBr calcium bromide

Ag gas cross-sectional area CCL casing collar log

a location of discontinuity in a composite CEC Commission for Environmental Cooperation


reservoir
CENELEC Comité Européen de Normalisation
a pumping well hydrodynamic constant Electrotechnique

aD dimensionless location of discontinuity in the CO2 carbon dioxide


composite reservoir
CT coiled tubing
ADC analog-to-digital converter
CTC convolution type curve
ANSI American National Standards Institute
CTS cable telemetry system
AOF absolute open flow
CTU cumulative tool usage
API American Petroleum Institute
CV circulating valve
ASCII American Standard Code for Information
Interchange D non-Darcy coefficient

ASIC application-specific integrated circuit dc casing diameter

ASME American Society of Mechanical Engineers dt tubing diameter

ASTM American Society for Testing and Materials DAC digital-to-analog converter

B formation volume factor DAV Dual-Action Valve

BHA bottomhole assembly DGA DST gauge adapter

BHP bottomhole pressure DHSIT downhole shut-in tool

BOP blowout preventer dm droplet diameter

BOST Battery-Operated Shut-In Tool DNV Det Norske Veritas

BOV bleedoff valve DST drillstem test

BWPD barrels of water per day DWLA DST LINC wireline adapter

C concentration DWT deadweight tester

C performance coefficient EEPROM electrically erasable (user) programmable


read-only memory
C wellbore storage coefficient
EFST explosive-free shut-in tool
CD dimensionless wellbore storage coefficient
ELMF enhanced liquid measurement flowmeter
CDf dimensionless fracture storage coefficient
EMC electromagnetic compatability
Cd drag coefficient
EN European standards
ct total compressibility
EOP extreme overbalanced perforating

Introduction to Testing Services ■ Nomenclature 13


ERS Easy Record Software HF hydrofluoric acid

ESD emergency shutdown HOOP hold-open

ESFA EFST actuator HP high pressure

EZGC subsea pressure and temperature carrier HPHT high pressure, high temperature

EZTH latch assembly of SenTREE 3 system HPU hydraulic power unit

EZTM SenTREE 3 system HSE health, safety and environment

EZTV valve assembly of SenTREE 3 system ID inside diameter

EZV E-Z Valve IEC International Electrotechnical Commission

F number of flow steps IRDV IRIS dual-valve tool

FCD dimensionless fracture conductivity IPR inflow performance ratio

fg gas void fraction ISO International Standards Organization

FASC Fullbore Annular Sample Chamber k permeability

FCP flowhead control panel kf fracture permeability

FHH data header flowline tool kh horizontal permeability

FLXH FlexPac hydraulic hold-down kro relative permeability to oil

FLXP FlexPac retrievable packer krw relative permeability to water

FPM Formation Protection Module kv vertical permeability

GFI ground fault interruption kx directional permeability

GLR gas/liquid ratio ky directional permeability

GOR gas/oil ratio kz directional permeability

GR gamma ray kh permeability-thickness product (flow capacity)

GUI graphical user interface khave average permeability-thickness product

GVF gas volume fraction L length

H2S hydrogen sulfide L number of layers

h height or thickness Lp horizontal well perforated interval

hb bottom nonopen interval length LCD liquid crystal display

hD dimensionless reservoir thickness LDCA DLWA/LINC downhole coupler assembly

hL height of liquid level LP low pressure

hLF height of gas column LRT layered reservoir testing

hp perforation interval LRT LINC running tool

ht reservoir thickness excluding gas cap LRTC LINC running tool cartridge

hw well open interval length LRTL LINC running tool latch

hwd penetration ratio (hw /rw) LSCI LINC surface computer interface

HAZOP Hazard and Operability LUBV lubricator valve

HCl hydrochloric acid M number of flow steps preceding the transient

14
M mobility ratio pwf wellbore flowing pressure at a constant
flow rate
m (p) gas pseudopressure function
pwi initial wellbore pressure
max maximum
pws bottomhole shut-in pressure
MCCV multicycle circulating valve
p0 arbitrary reference pressure
MCS master control station
PC personal computer
MCVL multicycle circulating valve with lock
PCTV PCT valve
min minimum
PFSV pump-through flapper safety valve
MIRV multiple-opening, internally operated
reversing valve PIPK Positrieve packer

MQD mean quadratic deviation PowerLINC power-latched inductive coupling

MSDST multislickline downhole shut-in tool PSPC compression-set PosiTest packer

MWPT measurements-while-perforating tool PSPK PosiTest cased hole packer

n inertial effect exponent PTSV pump-through safety valve

NACE National Association of Corrosion PTV pipe tester valve


Engineers
PVT pressure-volume-temperature
NACE NACE specifications for oilfield equipment
MR-01-75 material requirements Q capacity

NAS National Aerospace Standard Qo oil capacity

NEC National Electrical Code q flow rate

NPD Norwegian Petroleum Directorate qD dimensionless flow rate

NPT National Pipe Thread qg flow rate of gas

OD outside diameter qin flow rate into a closed chamber

p pressure qout flow rate out of a closed chamber

p* extrapolated pressure at infinite qr constant surface flow rate


shut-in time
qs sandface flow rate
pa applied pressure
qt total flow rate
pc casing head pressure
qwbf wellbore flow rate
pc computed pressure
r radial distance
pD dimensionless pressure
rD dimensionless radial distance
pDD drawdown pressure
reD dimensionless reservoir outer radius
pi initial pressure
reH dimensionless inner radius of horizontal
pmax maximum pressure flow region

pR reservoir pressure reV dimensionless outer radius of vertical


flow region
pwbD dimensionless wellbore pressure
rf radial distance to the fluid front
pwbf wellbore flowing pressure
rtD dimensionless radial distance to the
pwD dimensionless wellbore pressure fluid front

pwDC convolved dimensionless wellbore rw wellbore radius


pressure

Introduction to Testing Services ■ Nomenclature 15


RA radioactive SSV surface safety valve

Re Reynolds number STAF surface testing acquisition front end

RETV retainer valve in SenTREE 3 system STAN surface testing acquisition network

RIH running in hole SXAR explosive automatic gun release sub

RSM riser sealing mandrel T temperature

S saturation T time starting with the first flow rate

s skin factor t time

s′ pseudoskin factor ta gas pseudotime function

S.A. Stub Acme tD dimensionless time

SAM subsea accumulator module tDf dimensionless time for fractured well

S.A.T. Safety Analysis Table ti interval time

SBSA SMART Basic Services Acquisition tp production time before shut-in

SBSV single-ball safety valve t0 starting time

SCM subsea control module t0 time corresponding to the arbitrary


reference pressure p 0
SCPU SMART Central Processing Unit
TCP tubing-conveyed perforating
SCSSV surface-controlled subsurface safety
valve TFTV tubing fill/test valve

SCTT subsea completion and test tree THRT tubing hanger running tool

SCU surface control unit TTP through-tubing perforation

SFRCT sandface rate-convolution type function TTV tubing test valve

SHORT single-shot hydrostatic overpressure UPP universal pressure platform


reverse tool
UPS uninterruptible power supply
SHRT hydrostatic reference tool
V volume
SHRV single-shot hydrostatic overpressure
reverse tool Vc critical velocity

SHRV-T single-shot hydrostatic overpressure Vs settling velocity


reverse valve (internal/external)
w width
SIP selective inflow performance
wD dimensionless width
SJB safety joint
WCQR UNIGAGE CQG sensor
SLPJ slip joint
WP working pressure
Sn sensor output
WT working temperature
SORTIE single-shot hydrostatic overpressure
reverse valve (internal/external) xD dimensionless distance

SPV shear pin valve xe reservoir length

SRC Schlumberger Reservoir Completions xw distance from a boundary to the well


Center
yD dimensionless distance
SRO surface readout
ye reservoir length
SSJ subsea spanner joint

16
yw distance from a boundary to the well

Z gas compressibility factor

z gas deviation factor

zw distance from a boundary to the well

ZnBr zinc bromide

α characteristic front constant in a two-


bank model system

α fault barrier parameter

γ total compressibility ratio in a two-bank


model system

γ pressure gradient

γL pressure gradient of liquid

γg pressure gradient of gas

Δ difference

Δp change in pressure

Δp/Δq rate-normalized pressure

Δq change in rate

Δt elapsed time

Δti elapsed time interval

η diffusivity constant (k /φct μ)

θ angle between two intersecting boundaries

κ permeability ratio (k1h1/[k1h1 + k 2h 2 ])

λ interporosity pseudosteady-state flow parameter

μ viscosity

μg gas viscosity

μl liquid viscosity

μo oil viscosity

μw water viscosity

ρg gas density

ρl liquid density

τ superposition time

φ porosity

ω storativity ratio

Introduction to Testing Services ■ Introduction 17

Você também pode gostar