Você está na página 1de 8

Installation and Service Guide | V1.

Lucid arena | LED lamp

Read these instructions before installing the device, putting it into


operation, storage or handling it in any other manner

This Installation and Service Instructions, Edition 01-2010 is, for the LED
lighting arena Lucid 60 ° / 120 °

IP66
Lucid Arena Installations and Service Guide | V1.1 • Page 1
Introduction

This installation and service manual is for people (Electricians, service technicians),
which are responsible for the installation and maintenance of the LED light "Lucid
arena”. These people must be familiar with all the relevant electrical regulations and
adhere to them in all cases. This guide is not suitable for users without special
knowledge.

Intended Application
The LED light series „Lucid arena“ is a luminaire for professional use in industrial
buildings and outdoor applications. They are used to illumination of work, storage,
corridors and footpaths.

The installation and maintenance of the device is reserved exclusively for electrical
engineering technicians.
For questions about the handling of the lights that are not answered in this manual,
please contact us at:

LEiDs GmbH & Co. KG


Donaustr. 22-24
71522 Backnang
Germany
Phone +49 7191 323020
Telefax +49 7191 323029
Email: leds@led-ideas.eu

EU-Directives
LED lamp series Lucid arena was approved by the German Certification body VDE and
satisfies the requirements of the European Union Directives.

Name plate
For precise identification, you will find information on model / item number on the
nameplate of the lamp. Write down this information when you have questions or when
spare parts need to be ordered.

Page 2 • Lucid Arena Installations and Service Guide | V1.1


Safety Precautions

Risk of elecrticity
• Connect the „power supply“ (transformer) to the appropriate power source
from the mains supply.
• Use only the integrated „power supply“ to supply power to the lamp.
• Unplug the lamp from the mains and from any other device if a malfunction
occurs.
• Do not open the Lucid Arena as a replacement of the light source is not
planned and is not provided!
• Make sure, that only qualified personnel (electricians) are responsible for
installation and maintenance of the lamp.
• If the safe operation of a device is not ensured according to the safety
regulations. Then you should turn off the lamp and ensure that no accidental
operation of the lamp is possible.

Safe operation is for example no longer possible,


– if the lamp power supply or cables are visibly damaged
– if foreign materials have entered into the lamp.

Please note: A terminal clamp is not in the scope of supply of the lamp. Please use an
adequate terminal clamp that corresponds to the safety standard for installation.

Installation
• The installation steps described in this manual should only be carried out
by trained personnel. And should be carried out, according to the local
electrical safety standards.
• Perform only the maintenance work described in this manual. Any further
attempts to repair or adjustment of the lamp could lead to physical injury,
property damage and damage to the lamp.
• For all work carried out on ceilings, high poles or any other high mounted
lamps, the adequate safety ladders or the appropriate installation machinery
should be used in accordance with the safety standards.
• If necessary a safety net should be mounted.

Lucid Arena Installations and Service Guide | V1.1 • Page 3


Production Description

Models
The LED lamp series “Lucid arena” comes complete with matching power supply for
driving the light source. The connection of the lamp is done via a 3-wire jacketed
connection cable that suits the operation demands of the lamp. The series “Lucid arena”
are maintenance free. All lamps can be mounted with the bracket construction, which
allows for mounting on walls and ceilings. The reliable “Lucid arena” lamp has an
average life span of 60,000 hours.

Luminous
The luminosity of the model Lucid arena compares to a 500 watt Halogen flood light,
but at a significantly lower power consumption. The lamp is designed for applications in
warehouses and commercial properties.

Pre-assembly
After unpacking the lamp , the screws of the bracket clamp should be loosened with an
“Allen key” 5mm and the bracket should be placed in vertical position. Please make sure
that the cable is not pinched between the bracket and heat sinks. Tighten the screws
securely when the bracket is vertical.

Bracket in packing position Bracket in vertical position

Temperature control point (tc)


The maximum temperature of 80 ° C may not be exceeded at the mark shown on the
picture. By complying with the maximum temperature control at the tc point, this
ensures that no components over heat and effect the performance of the lamp. At high
temperatures sufficient cooling should be provided. In case this temperature are
reached the lamp has to be cut-off from the power immediately.

Temperature control point (tc)

Page 4 • Lucid Arena Installations and Service Guide | V1.1


Installation
• LED light should be mounted horizontally at the desired position.
• Minimum of 2 mounting-screws with a diameter of 6mm should be used for
the mounting of the mounting bracket on the surface(wall/ceiling).
• The power connection is via a 1m long flexible cable.
The cable has loose ends and must have an additional terminal box (not
included). If necessary, the cable ends should be safe guarded with ferrules.
• The „earthing“ of the lamp is done via the green and yellow cable.
• When the ideal angle of orientation of the LED lamp has been approved, all
screws should be tightened and should be checked at least once a year, and if
necessary tightened again.
• When adjusting the LED light, precaution should be taken, that no damage
is done to the power cable.

Cleaning - Maintenance- Information


• All parts of the device are maintenance free.
• Use only with supplied „power supply“!
• The LED module should not be opened!
• For cleaning we recommend a damp cloth.
• No cleaning agents should be used.
• Damaged cable should be replaced immediately with new cable.

Technical data
Power supply voltage input 100 V - 240V
Power supply voltage output 24V constant current 3,85A
Operating voltage for module LED 24V direct current
Permitted ambient Temp -30° to +50°
Protection Class I
Type of Protection IP 66
No. of LEDs/Type 1120 leds / ALDER AS-3528WCA2
Total power consumption 100 Watt
Total Weight / Light field app. 5,8 kg / app. 500 g
Dimensions LxBxH 322 x 220 x 160mm

Item-no. Colour Angle of Luminous flux Light intensity


Temperature Radiation (Lumen) (Candela)
18010 col d whi te 120° 8050 l m 2562
18013 col d whi te 60° 7645 l m 9080
18020 da yl i ght whi te 120° 8050 l m 2562
18023 da yl i ght whi te 60° 7645 l m 9080
18030 norma l whi te 120° 8050 l m 2562
18033 norma l whi te 60° 7645 l m 9080
18040 wa rm whi te 120° 7245 l m 2306
18043 wa rm whi te 60° 6880 l m 8170

Lucid Arena Installations and Service Guide | V1.1 • Page 5


Warrenty

1. The warranty is valid for 2 years, unless an additional warranty extension was
agreed at the time of purchase. The warranty extension is an additional service
with a cost factor.
The warranty starts on the date of delivery to the end customer.
2. To assert a warranty claim, the purchase receipt showing date of delivery and
date of purchase has to be submitted. When warranty claim is filed, the
defective unit has to be returned to your dealer or directly to: LEiDs GmbH &
Co.KG, Donau Str. 22-24, D-71522 Backnang, Email: leds@led-ideas.eu
3. The warranty covers all material and construction errors.
4. The warranty excludes all the errors and defects occurring due to the following
points:
a) Not following the instruction manual.
b) Natural wear and tear.
c) External influences for example, transport damage, damage due to
shock impact, overheating, damage caused by chemicals, damage caused
by electrochemical reactions, eg. trough water, acids and improper use.
d) Repairing and modification done by unauthorized personal.
e) Use of inappropriate accessories.
f) Furthermore, excluded are:
Damage caused by improper handling, incorrect installation and improper
maintenance (see installation instruction), damage due to force majeure,
fire, vandalism and any further accidents
5. Within the warranty period. LEiDs will eliminate any errors that occur, this will
be done after consultation with the dealer. The malfunctioning parts will be
repaired or replaced. Exchanged parts will automatically become the property
of LEiDs GmbH& Co.KG. Further claims, of whatever kind, in particular claims
for financial damages are not included.
6. Excluded from the guarantee:
a) Costs for demounting and remounting of the lamp.
b) Costs for sending the defect lamp to LEiDs.
7. LEiDS LED-Lamps are subject to continuous development according to the
technical development of the LEDs and Power Supply. For this reason, in case of
a warranty repair claim, the situation could arise that the original parts or the
original lamp is no longer available, in such cases LEiDs reserves the right to
provide parts or lamps that for fill the same function or provide parts and
lamps that perform better then the originals.
LEiDs, legally reserves the rights to change the warranty period, the fixed price
conditions without any prior notice.
Warranties, with valid registration are not effected, when the new
amendments are introduced. LEiDs reserve the legal rights to make the final
decision if a warranty case is valid or not.

Page 6 • Lucid Arena Installations and Service Guide | V1.1


Legal Notice

This manual contains the necessary legal information explaining how to use the LEiDs
LED Lamp.
Understanding and following the instructions in this manual are a prerequisite for the
safe implementation and operation of the lamp.
This manual does not and cannot cover all conceivable applications. The LED lamp is
designed for indoor, in sheltered out door areas and outdoor areas. Further more we
would like to point out this manual is not a part of any prior or existing legal agreement
or commitment or any other legal relationship.
The manual contains information that is protected by copyright. Photocopying or
translation into any other language is not allowed without the prior written consent of
LEiDs Germany. This manual is containing the necessary information for the intended
use.

LEiDs LED-lamps are subject to the continuous improvement due to the continuous
developments in the LED industry.

Lucid Arena Installations and Service Guide | V1.1 • Page 7


Page 8 • Lucid Arena Installations and Service Guide | V1.1

Você também pode gostar