The Miniature UV-Vis Light Source

FOR NEW OPTICAL AND ANALYTICAL SOLUTIONS

Heraeus Noblelight GmbH


F I B E R L I G H T F O R I N N O V A T I V E S O L U T I O N S

FiberLight is a miniature UV-Vis light FiberLight is a complete UV-Vis light


source with a continuous spectrum source with a shine-through design
covering the whole range from vacuum deuterium lamp, a 0.25 Watt tungsten
UV to near Infrared. This light source lamp, shutter, optical system and SMA
was developed in response to customer 905 connector. All elements are mounted
requests for a small UV-Light source on a printed circuit board driven by an
with negligible heat generation. external 12 Vdc/600 mA power supply.
The features of this light source open Both lamps and the shutter can be
the way for new solutions in small controlled by a TTL signal.
spectroscopy equipment and UV optics.
FiberLight Lamp Modules
Features are A lamp module consists of the
■ small size Deuterium lamp, the tungsten lamp
■ low power consumption (6 W) and the prealigned mounting ring.
■ low heat generation There are 4 modules available with
■ easy coupling to optical fibers, different spectral and optical features.
measuring cells and capillaries The lamp modules are interchangeable:
■ lifetime up to 3 years
■ robust mode of operation 1. DTM 6/10 UV-Vis Lamp Module,
spectral range 200 – 1100 nm,
Current applications FiberLight is a complete system consisting aperture 1.0 mm,
of interchangeable lamp modules and the
■ Modular Miniature UV-Spectrometers for fibers of 400 – 600 µm diameter
power supply
■ Handheld equipment for outdoor 2. DTM 6/50 UV-Vis Lamp Module,
spectroscopy spectral range 200 – 1100 nm,
■ for analysis in waters and waste water aperture 0.5 mm,
■ for oil-in-water analysis for fibers of 200 – 600 µm diameter
■ for deep sea water analysis 3. DTM 6/10S UV-Vis Lamp Module,
■ Sealed equipment for process control spectral range 185 – 1100 nm,
■ Measurements in the vacuum aperture 1.0 mm,
UV spectral range for fibers of 400 – 600 µm diameter
■ Measurements under hyper- and 4. DTM 6/50S UV-Vis Lamp Module,
zero-gravity spectral range 185 – 1100 nm,
aperture 0.5 mm,
Miniature Deuterium Lamp for fibers of 200 – 600 µm diameter
FiberLight incorporates a miniature 4
4 different lamp modules are available: Deuterium lamps with 1.0 mm or 0.5 mm aperture
Deuterium Lamp – an electrode-less
Standard Quartz as well as Suprasil Deuterium lamps with spectra ranging from 200 nm to
high frequency excited gas discharge 1100 nm and 160 nm to 1100 nm respectively. The fiber limits the spectral output to 185 nm
lamp. The Deuterium Lamp features at short UV wavelength.
small size, 3 Watt power consumption,
and negligible heat generation.
Spectral Distribution of FiberLight Spectral Distribution (Vacuum UV range)
– measured with optical fiber 400 µm. – measured under vacuum without optical fiber.
5 5
100 120
with Suprasil window
100
80

80
Rel. Intensity (%)
Light intensity (%)

60
60
40
40
with fused silica window
20
20

0 0
200 300 400 500 600 700 800 900 1000 1100 150 190 230 270 310
Wavelength (nm) Wavelength (nm)
The high frequency excited 102
Deuterium lamp 100
The high frequency excitation provides 98 37

immediate ignition of the Deuterium lamp. 96


11.85

Light Intensity (%)


55
94
The lamp can be switched on and off at LED (green) 51
92
any time and can be operated in cycles. 4

9.5
90

3
A A
88
Lamp
Life 86 unit

The continuous operating life of the 84


FiberLight Deuterium lamp is more than 82

157

141
1000 hours. As the lamp can be switched 80
0 2 4 6 8 10 12
on and off on demand or operated in
Cycles
cycles the lifetime can be extended con-
siderably. The number of ignitions affect 4 Control Power
Cyclic Operation measured at 230 nm, board supply
the operating life only insignificantly. measuring time: 15 sec; off = 75 sec. circuit
board
For example in nitrate measurements in

2
A A
waste water FiberLight is switched on Terminal strip X1
A = Mounting holes
every 30 seconds for just 1 second. The
measurement is started after a delay of
0.5 seconds. After this delay FiberLight
has a very good pulse-to-pulse-stability 4
Dimensional Outline of FiberLight.
of approx. 0.1 % in the UV spectral range.
Lamp Life Characteristic FiberLight DTM 6/10
– measured at 250 nm.
A
5
120

10.8
100
B
Relative Intensity (%)

80
11.2

60
C
40
D
20
E
0
0 200 400 600 800 1000 1200
Operating Time (h)
A = Fiber
B = Optical Lens
C = Aperture
FiberLight with Suprasil window,
D = Deuterium Lamp
spectral distribution measured under vacuum
E = Tungsten Lamp
with optical fibers of different lengths.
5 4
120 100 Cross section of the FiberLight lamp module
showing: the tungsten lamp, the rf excited
100 Deuterium lamp and the optical system which
Fiber 20 cm / 400 µm 80 projects the UV and visible light output into
80 the fiber.
Rel. Intensity (%)

Rel. Intensity (%)

60
± 20°
60 (FWHM)
40
40
Fiber 50 cm / 400 µm
20
20

0 0
150 190 230 270 310 -50 -30 -10 0 10 30 50
3 Spatial Intensity Distribution of the Deuterium
Wavelength (nm) Angle (deg)
lamp – measured without lens.
General Specifications UV-Vis Light Source FiberLight
Spectral Distribution 200 – 1100 nm, Options: 185 – 1100 nm, 160 – 1100 nm
Power Consumption Approx. 6 Watt (both lamps in operation)
Power Requirements 12 Vdc/0.6 Adc
Ambient Temperature 5 – 35 °C
Relative Humidity Max. 90 %, non-condensing
Dimensions (LxWxH) 157 x 55 x 37 mm
Shutter Lamp off/dark current measurement, TTL controlled
Functions Deuterium and tungsten lamp can be triggered separately by a TTL signal
Light exit SMA 905 connector for coupling to optical fibers
Optical Fiber Fiber diamater 200 µm, 400 µm, 600 µm
Numerical aperture Deuterium Lamp 0.245, Tungsten Lamp 0.057
Cooling Not required

Deuterium Lamp US Patent No. 5801.495, US Patent No. 5814 951


Spectral Distribution 200 – 400 nm line free, Option 160 – 400 nm
Window material Fused silica, Synthetic silica
Light output (radiant intensity) > 5 x 10–8 W/nm sr @ 240 nm
Stability < 1 x 10–3 AU
Drift < 0.25 %/h
Exciting frequency 250 kHz
Ignition voltage Approx.1 kV
Life ≥1000 h @ 240 nm (50 % intensity loss)
Power consumption Approx. 3 W

Tungsten Lamp
Spectral Distribution 400 – 1100 nm
Voltage 5 Vdc
Current 45 mAdc
Life > 2000 h

Replacement Lamp Module DTM 6/10


Part No. 45006253

Options
FiberLight Type DTM 6/10 DTM 6/50 DTM 6/10S DTM 6/50S
Part No. 45006280 45006281 80000755 80001017
Aperture size 1.0 mm 0.5 mm 1.0 mm 0.5 mm
Window material Fused silica Fused silica Synthetic silica Synthetic silica
Spectral distribution with optical fiber 200 – 1100 nm 200 – 1100 nm 185 – 1100 nm 185 – 1100 nm
Spectral distribution at operation under vacuum:
without opical fiber 185 – 1100 nm 185 – 1100 nm 160 – 1100 nm 160 – 1100 nm
Recommended Fiber Diameter 400 – 600 µm 200 – 600 µm 400 – 600 µm 200 – 600 µm
Replacement Lamp Module DTM 6/10 DTM 6/50 DTM 6/10S DTM 6/50S

Part No. 45006253 45006266 80000756 80001018

Products as supplied may differ from the illustrations and descriptions in this brochure. HNG - B 154 E · D 2C 01.02/M+T
Printed in Germany

Heraeus Noblelight GmbH Heraeus Noblelight Ltd. Heraeus Noblelight, Inc.


P.O.Box 15 63 8, Caldbeck Road 2150 Northmont Parkway
D-63405 Hanau Bromborough, Wirral USA-Duluth, GA 30096
Germany Merseyside CH62 3PL/England Phone (770) 418 0707 REG. NO. 39254
Phone +49 (6181) 35-50 86 Phone +44 (151) 343 0545 Telefax (770) 418 0688
Telefax +49 (6181) 35-79 70 Telefax +44 (151) 343 9883
E-Mail: hng-analyticallamps@ E-Mail: E-Mail:
heraeus.com hnl-bromborough@heraeus.com analytical@heraeusnoblelight.com
Internet: www.heraeus-noblelight.com Internet: www.heraeus-noblelight.com Internet: www.heraeusnoblelight.com

Você também pode gostar