Você está na página 1de 4

Firmware

Note that most of the modules supported by RSLogix 5000 software utilize
Flash-ROM for the storage of firmware. If you possess a module that
RSLogix 5000
requires a firmware change, the ControlFLASH software tool can be used to V17.00.00 Release Notes
perform an update to this Flash-ROM. This software tool and the firmware Hardware Requirements
images for most of the supported modules are contained on a CD-ROM
shipped with RSLogix 5000 software. Starting with RSLogix 5000 V10.00.00 To use RSLogix 5000 software effectively, your personal computer must
software, you can access the ControlFLASH tool from within RSLogix 5000 meet these minimum requirements.
software (from the Tools menu), or you can automatically update your Characteristic Minimum Required Recommended
firmware as part of the project download process. For additional information
Processor Pentium 3 or better Pentium 4 or better
and assistance in performing a Flash-ROM update, please review the
ControlFLASH Firmware Upgrade Kit User Manual. Speed 733 MHz 2.8 GHz
In addition, Rockwell Automation Services & Support has created a web site RAM Memory 256 MB 1 GB
from which you can download firmware images for ControlLogix products.
Go to http://support.rockwellautomation.com/ControlFlash for a matrix Hard Disk Space 3.0 GB free 3.0 GB free
detailing the versions of firmware that were released with each of the Optical Drive DVD-ROM Drive DVD-ROM Drive
versions of RSLogix 5000 software, and to download the ControlFLASH
firmware kits and release notes. Note that you need your RSLogix 5000 Video 1024x768 pixels True 1280x1024 pixels True
software serial number to complete the download. Colors Color
Pointing Device Any Windows-compatible pointing device
Electronic Data Sheets
The version of RSLinx Classic provided with this version of RSLogix 5000
Software Requirements
software includes an updated set of Electronic Data Sheets (EDS) files for ƒ This version has been tested on these operating systems:
Rockwell Automation products. Installing this software ensures that ƒ Microsoft Windows Vista Business and Home Basic Service Pack 1
RSLinx Classic and RSNetWorx will be able to work with the new versions and User Account Control (UAC) turned off
of firmware. These EDS files are also available separately by contacting ƒ Microsoft Windows XP Professional Service Packs 2 and 3
Technical Support: (phone +1 440-646-3434), or via the Internet: ƒ Microsoft Windows Server 2003 R2 Standard Edition Service Pack 2
http://rockwellautomation.com/resources/eds/. You can install them using ƒ Microsoft Windows 2000 Professional Service Pack 4
the EDS Hardware Installation Tool, located in the ƒ This version is expected to operate correctly on all editions and service
Rockwell Software>RSLinx>Tools menu in the Windows Start Menu. packs of these operating systems, but has not been tested:
ƒ Microsoft Windows Vista
ƒ Microsoft Windows XP
ƒ Microsoft Windows Server 2003
ƒ Microsoft Windows 2000
ƒ RSLogix 5000 software is supported for 32-bit operating systems
(x86). RSLogix 5000 software is not supported for 64-bit operating
systems (x64) and has not been tested in that configuration.
ƒ RSLogix 5000 software versions earlier than version 17 are not
supported on Microsoft Windows Vista operating systems at this time
and have not been tested on those operation systems.

Doc ID RSL5KRN-07.25.08
ƒ Note that the Chinese, Japanese, and Korean editions of * RSLogix 5000 software is also expected to be compatible with RSNetWorx
RSLogix 5000 software are only supported on Microsoft Windows software, version 8.00.00. However, to use the RSLogix 5000 software
Vista, Microsoft Windows XP, and Microsoft Windows Server 2003. version 17 Produced/Consumed Tag Structures Status enhancement, you
ƒ RSLogix 5000 software also does not support Windows Vista with User must have RSNetWorx for ControlNet software, version 9.00.00 or later.
Account Control (UAC) turned on, Windows NT 3.51, Windows NT ** To use the RSLogix 5000 software version 17 Runtime Partial Import
3.50, Windows Me, Windows 98SE, Windows 98, Windows 95, or feature, you must have RSLinx Classic software version 2.54.00 or later.
Windows 3.x operating systems. Starting with version 14, Also note that in a system using Runtime Partial Import with FactoryTalk
RSLogix 5000 software does not support Microsoft Windows NT View, you must have RSLinx Enterprise software version 5.17.00 or later.
Workstation version 4.0. Hardware
RSLogix 5000 Version
Revision Information V17.00 V16.03/ V15.03/ V14.01/
While RSLogix 5000 software continues to extend its functionality with each V16.00 V15.02/ V14.00
release, the physical controllers that it supports vary. New controllers are V15.01/
added and, in some cases, support for existing controllers may be removed. V15.00
While a specific controller may not be supported by the current release, the Controllers
side-by-side installation of multiple versions of RSLogix 5000 software, in ControlLogix L61 – Ser. A & L55 – Ser. A L55 – Ser. A L61 – Ser. A
most cases, provides a means to support the older hardware. If you decide 1756-L1, -L53, B V17.02 V16.21 V15.03 & B V14.2
to migrate from one controller to another, a project created for one controller -L55, -L61, L62 – Ser. A & L61 – Ser. A L62 – Ser. A
L61 – Ser. A &
can be easily converted to another controller via the Controller Properties -L62, -L63, B V17.02 & B V16.21 & B V14.2
B V15.03
configuration dialog box within RSLogix 5000 software. Additionally, if you -L64, L63 – Ser. A & L62 – Ser. A L63 – Ser. A
open a project that is configured for a controller that is no longer supported L62 – Ser. A &
-L60M03SE B V17.02 & B V16.21 & B V14.2
and the older version of RSLogix 5000 software is not installed, B V15.03
L64 – Ser. B L63 – Ser. A
RSLogix 5000 software versions 13 and later provides an appropriate V17.02 & B V16.21 L63 – Ser. A &
warning and automatically provides the option to convert the project to one L65 – Ser. B L64 – Ser. B B V15.03
of the controllers supported by the release. V17.02 V16.21 L60M03SE –
Software L60M03SE– L60M03SE– Ser. A V15.03
RSLogix RSLinx RSNetWorx RSNetWorx RSNetWorx Ser. A V17.02 Ser. A V16.21
5000 Classic for for DeviceNet for GuardLogix L61S – Ser. B L61S – Ser. B N/A L61S – Ser. B
Version Version* ControlNet Version EtherNet/IP 1756-L61S, V17.06 V16.21 V14.33
Version Version -L62S, -L63S L62S – Ser. B L62S – Ser. B L62S – Ser. B
V17.00 2.54.00.11 9.00.00 9.00.00 9.00.00 V17.06 V16.21 V14.33
(CPR 9 (Build 24) (Build 24) (Build 24)
L63S – Ser. B
SR 1)** (CPR 9 (CPR 9 (CPR 9
V17.06
SR 1)* SR 1) SR 1)
FlexLogix N/A L34 – Ser. A L34 – Ser. A & N/A
V16.03/ 2.51.00.21 8.00.00 8.00.01 8.00.00
1794-L33, -L34 & B V16.21 B V15.03
V16.00 (CPR 7) (Build 15) (Build 01) (Build 15)
(CPR 7) (CPR 7) (CPR 7) CompactLogix L43 – Ser. A L43 – Ser. A L43 – Ser. A N/A
V15.03/ 2.50.00.20 6.00.00 6.00.00 6.00.00 1768-L43, L45 V17.02 V16.21 V15.03
V15.02/ (CPR 7) (Build 97) (Build 97) (Build 97) L45 – Ser. A L45 – Ser. A
V15.01/ (CPR 6) (CPR 6) (CPR 6) V17.02 V16.21
V15.00
V14.01/ 2.43.01.23 5.11.00 5.11.00 5.11.00
V14.00 (CPR 6) (Build 31) (Build 31) (Build 31)
(CPR 6) (CPR 6) (CPR 6)
CompactLogix L23E-QB1 – N/A N/A N/A 1756-CNB, Ser. E V11.02 Ser. E V11.02 Ser. D V5.46 Ser D. V5.45
1769-L23E-QB1, Ser. A V17.02 -CNBR Ser. D V5.50 Ser. D V5.51 Ser. B V2.30 Ser B. V2.30
-L23E-QBFC1, L23E-QBFC1 Ser. B V2.30 Ser. B V2.30 Ser. A V1.19 Ser A. V1.19
L23-QBFC1 Ser. A V17.02
Ser. A V1.19 Ser. A V1.19
L23-QBFC1-
Ser. A V17.02 1756-DH485 Ser. A V1.2 N/A N/A N/A
CompactLogix L31 – Ser. A L31 – Ser. A L31 – Ser. A N/A 1756-DHRIO Ser. D V6.2 Ser. D V6.2 Ser. D V6.1 Ser. C V5.3
1769-L20, V17.02 V16.21 V15.03 Ser. C V5.4 Ser. C V5.4 Ser. C V5.3 Ser. B V2.21
-L30, -L31, L32C – Ser. A L32C – Ser. A L32C – Ser. A Ser. B V2.21 Ser. B V2.21 Ser. B V2.21
-L32C, -L32E, V17.02 V16.21 V15.03 1756-DNB Ser. C V10.005 Ser. B V7.002 Ser. B V6.002 Ser. A V6.002
-L35CR, -L35E L32E – Ser. A L32E – Ser. A Ser. B V7.002 Ser. A V7.002 Ser. A V6.002
L32E – Ser. A
V17.02 V16.21 V15.03 Ser. A V7.002
L35CR – Ser. L35CR – Ser. A
A V17.02 V16.21 L35CR – Ser. 1756-ENBT Ser. A V4.007 Ser. A V4.006 Ser. A V3.6 Ser. A V3.6
L35E – Ser. A L35E – Ser. A A V15.03 1756-ENET Ser. B V2.7 Ser. B V2.7 Ser. B V2.7 Ser. B V2.7
V17.02 V16.21 L35E – Ser. A Ser. A V1.18 Ser. A V1.18 Ser. A V1.18 Ser. A V1.18
V15.03
1756-EWEB Ser. A V4.006 Ser. A V4.006 Ser. A V2.2 Ser. A V2.2
DriveLogix5720 N/A N/A N/A N/A
PowerFlex 700S 1756-EN2T Ser. A V1.003 Ser. A V1.003 N/A N/A
DriveLogix5730 Ser. A V17.02 Ser. A V16.21 Ser. A V15.03 N/A 1757-FFLD Ser. A V1.6 Ser. A V1.1 Ser. A V1.1 Ser. A V1.1
PowerFlex 1768-CNB Ser. V1.001 N/A N/A N/A
700S 2 1768-ENBT Ser. A V1.3 Ser. A V1.3 Ser. A V1.1 N/A
SoftLogix Ser. A V17.00 Ser. A V16.03 Ser. A V15.00 N/A 1768-EWEB Ser. A V1.002 N/A N/A N/A
1789-L60 1769-ADN Ser. B V2.5 N/A N/A N/A
RSLogix V17.00 V16.03 V15.00 N/A 1769-SDN Ser. B V3.009 Ser B V2.002 Ser B V2.002 Ser. B V2.1
Emulate 5000
1784-PCIC, Ser. B V4.10 Ser. B V4.10 Ser. B V4.08 Ser. B V4.08
Communication Modules
-PCICS Ser. A V3.10 Ser. A V3.10
1734-ACNR Ser. A V1.082 Ser. A V1.081 Ser. A V1.079 Ser. A V1.078
1784-PCIDS Ser. B V3.016 Ser. B V3.016 Ser. A V2.008 Ser. A V2.008
1734-AENT Ser. A V2.004 Ser. A V2.3 Ser. A V1.033 Ser. A V1.032
Ser. A V2.008 Ser. A V2.008
1734-ADN Ser. B V3.003 N/A N/A N/A
Ser. A V3.003 1784-PKTCS Ser. B V4.10 Ser. B V4.10 Ser. B V4.08 Ser. B V4.08
1734-ADNX Ser. A V2.002 N/A N/A N/A 1788-CN2DN Ser. A V1.024 Ser. A V1.024 Ser. A V1.023 Ser. A V1.023
1738-ACNR Ser. A V1.082 Ser. A V1.081 Ser. A V1.079 Ser. A V1.078 1788-CNC, Ser. A V1.6 Ser. A V1.6 Ser. A V1.5 Ser. A V1.5
-CNCR
1738-ADN Ser. B V3.003 N/A N/A N/A
Ser. A V3.003 1788-CNF, Ser. A V1.6 Ser. A V1.6 Ser. A V1.6 Ser. A V1.5
-CNFR
1738-ADNX Ser. A V2.002 N/A N/A N/A
1788-DNBO Ser. A V2.002 Ser. A V2.002 Ser. A V2.002 Ser. A V2.002
1738-AENT Ser. A V2.004 Ser. A V2.3 Ser. A V1.033 Ser. A V1.032
1788-EN2DN Ser. A V2.005 Ser. A V2.002 Ser. A V2.002 Ser. A V1.05
1756-CN2, Ser. B 20.009 Ser. A V12.01 Ser. A V10.08 N/A
-CN2R Ser. A V12.01 1788-ENBT Ser. A V2.3 Ser. A V2.3 Ser. A V2.1 Ser. A V2.1
1794-ACN15, Ser. C V4.3 Ser. C V4.3 Ser. A V4.3 Ser. A V4.3
-ACNR15
1794-AENT Ser. B V4.1 Ser. A V3.1 Ser. A V2.12 Ser. A V2.12
Ser. A V3.1 Rockwell Automation
1794-ADN Ser. B V2.004 N/A N/A N/A For more information on the latest pricing or a demonstration of any
Rockwell Automation package, please contact your local Rockwell
56AMXN Ser. B V2.1 Ser. B V2.1 Ser. B V2.1 Ser. B V2.1
Automation sales office or Allen-Bradley distributor.
Motion Modules Corporate Headquarters
1756-HYD02 Ser. A V17.02 Ser. A V16.01 Ser. A V15.01 N/A Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI 53202-5302 USA,
Tel: (1) 414.212.5200, Fax: (1) 414.212.5201
1756-M02AE Ser. A V17.03 Ser. A V16.01 Ser. A V15.01 N/A Headquarters for Allen-Bradley Products, Rockwell Software Products, and Global
Manufacturing Solutions
1756-M02AS Ser. A V17.02 Ser. A V16.01 Ser. A V15.01 N/A Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA,
1756-M03SE Ser. A V17.10 Ser. A V16.20 Ser. A V15.05 N/A Tel: (1) 414.382.2000, Fax: (1) 414.382.4444
Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36,
1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640
1756-M08SE Ser. B V17.10 Ser. B V16.20 Ser. B V15.05 N/A Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay,
Ser. A V17.10 Ser. A V16.20 Ser. A V15.05 Hong Kong, Tel: (852) 2887 4788, Fax: (32) 2508 1846
Headquarters for Dodge and Reliance Electric Products
1756-M08SEG Ser. A V17.10 Ser. A V16.20 Ser. B V15.03 N/A Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA,
Tel: (1) 864.297.4800, Fax: (1) 864.281.2433
1756-M16SE Ser. A V17.10 Ser. A V16.20 Ser. A V15.05 N/A Europe/Middle East/Africa: Rockwell Automation, Bruhlstrabe 22, D-74834 Elztal-Dallau, Germany,
1768-M04SE Ser. A V17.10 Ser. A V16.20 Ser. A V15.05 N/A Tel: (49) 6261 9410, Fax: (49) 6261 17741
Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987,
1784-PM02AE Ser. A V17.03 Ser. A V16.01 Ser. A V15.01 N/A Tel: (65) 6356-9077, Fax: (65) 6356-9011
1784-PM16SE Ser. A V17.10 Ser. A V16.20 Ser. A V15.05 N/A ©2008 Rockwell Automation Inc. RSLogix 5000, RSLinx, and RSNetWorx
SERCOS Drives are trademarks of Rockwell Automation, Inc. Microsoft is a registered
Kinetix7000 V1.097 V1.97 V1.85 N/A trademark of the Microsoft Corporation. Windows 95, Windows NT,
(2099 Series) Windows 2000, and Windows XP are trademarks of the Microsoft
Corporation.
Kinetix6000 V1.99 V1.95 V1.85 N/A
(2094 Series)
Kinetix2000 V1.099 V1.97 N/A N/A
(2093 Series)
Ultra3000 V1.52 V1.52 V1.50 N/A
(2098 Series)
8720MC Series V3.85 V3.85 V3.85 N/A
1394C Series V1.87 V1.85 V1.85 N/A
Other Products
DriveTools N/A N/A V3.01 V3.01
Software
ControlLogix N/A Revision Revision 15.6x N/A