Você está na página 1de 4

T1= 100 C

T2= 60 C
t1= 30 C
t2= 60 C
Dt1= 40 C
Dt2= 30 C
DTML= 34.76059 C

ho= 4000 W/m2K


hi= 10000 W/m2K
do= 19.05 mm
di= 17.05 mm
rdo= 0.0004 m2K/W
rdi= 0.0004 m2K/W
k= 50 W/mK
U= 822.7901 W/m2K

M= 40 kg/s
CP= 3 J/g.K
Q= 4800000 W

A= 167.8282 m2
L tubo= 5m
a tubo= 0.299237 m2
N tubos= 560.8544
D casco= 29 in 31 in
N tubos = 553 657
L/D= 6.787945 6.350013
T1= 100 C
T2= 60 C
t1= 30 C
t2= 60 C
Dt1= 40 C
Dt2= 30 C
DTML= 34.76059 C

ho= 4000 W/m2K


hi= 10000 W/m2K
do= 19.05 mm
di= 17.05 mm
rdo= 0.0004 m2K/W
rdi= 0.0004 m2K/W
k= 50 W/mK
U= 822.7901 W/m2K

M= 40 kg/s
CP= 3 J/g.K
Q= 4800000 W

A= 167.8282 m2
L tubo= 4m
a tubo= 0.239389 m2
N tubos= 701.068
D casco= 33 in 32 in 31 in
N tubos = 749 703 657
L/D= 4.772131 4.92126 5.08001
T1= 100 C
T2= 60 C
t1= 30 C
t2= 60 C
Dt1= 40 C
Dt2= 30 C
DTML= 34.76059 C

R= 1.333333
S= 0.428571
FT= 0.83

COMO FT >0,75 , A TROCA É POSSÍVEL.


NO ENTANTO, ESTA ALTERAÇÃO SERVE PARA AUMENTAR O COEFICIENTE D TROCA DOS TUBOS, O QUE NÃO SE FAZ NECESSÁRIO
TERIA AINDA COMO CONSEQUÊNCIA UMA PERDA DE CARGA 8 VEZES MAIOR, SEM NENHUM GANHO NA TROCA TÉRMICA
E FAZ NECESSÁRIO POIS O MESMO NÃO É O CONTROLADOR
CA TÉRMICA