Você está na página 1de 8

EMCP 3

EMCP 3.3
GENERATOR SET
CONTROLLER

GENERAL DESCRIPTION FEATURES/BENEFITS


The Cat ® EMCP 3.3 places fully featured power ● A 64 x 240 pixel, 28 mm x 100 mm, white backlit
metering, protective relaying and engine and graphical display denotes text alarm/event
generator control and monitoring at your descriptions and is visible in all lighting conditions.
fingertips. Engine and generator controls, ● Textual display with multiple language capability,
diagnostics, and operating information are including character languages such as Arabic,
accessible via the control panel keypads; diagnostics Chinese, and Japanese.
● Advanced engine monitoring is available on
from the EMCP 3 optional modules can be viewed
systems with an electronic engine control module.
and reset through the EMCP 3.3. The EMCP 3.3
● Integration with the CDVR provides enhanced
features a graphical display with a white backlight
system performance.
visible in all types of light as well as an advanced ● Ability to view and reset diagnostics on EMCP 3
engine monitoring system. These features add to optional modules via the control panel removes
the sense of value and dependability that comes the need for a separate service tool for
with your purchase of Caterpillar products. troubleshooting.
● Fully featured power metering, protective relaying,
OPERATOR INTERFACE engine and generator parameter viewing, and
● Graphical display with positive image, expanded AC metering are all integrated into
transflective LCD, adjustable white this controller.
backlight/contrast ● Real-time clock allows for date and time stamping
● Two LED status indicators (1 red, 1 amber) of diagnostics and events in the control’s logs
● Three Engine Control Keys and Status as well as service maintenance reminders based
Indicators (Run/Auto/Stop) on engine operating hours or calendar days.
● ● Customer programmable protective relaying,
Lamp Test Key
● Alarm Acknowledgement Key available as alarm and shutdown, protects
● against undervoltage, overvoltage,
Display Navigation Keys
underfrequency, overfrequency,
● Two Shortcut Keys: Engine Operating Parameters overcurrent, and reverse power.
and Generator Operating Parameters ● Digital, 32-bit microprocessor-based system
eliminates the need for multiple switches, meters,
transducers, relays, and sending units, which
translates to less wiring and fewer opportunities
for mechanical failures.

LEHE4748-02
EMCP 3.3
GENERATOR SET CONTROLLER

FEATURES/BENEFITS (CONT’D) STANDARDS


● Expanded remote customer communications ● UL 508 Listed
are supported by MODBUS RTU (1/2 duplex) ● CSA C22.2 No.100,14, 94
protocol using RS-485, which easily interfaces ● Complies with all necessary standards for
with existing plant systems and equipment. CE Certification
● Simultaneous viewing of all AC L-L voltages, 98/37/EC Machinery Directive
all AC L-N voltages, or all AC line currents. – BS EN 60204-1 Safety of Machinery
● User-friendly, convenient, customer 89/336/EEC EMC Directive
programmability directs the customer to logical – BS EN 50081-1 Emissions Standard
parameter groups (Ex. AC metering, protective – BS EN 50082-2 Immunity Standard
relaying, engine monitoring) for quick keypad
73/23/EEC Low Voltage Directive
access.
● – EN 50178 LVD Standard
Set points and software are stored in nonvolatile
● ISO3046, ISO8528
memory, preventing loss during a power outage.
● IEC529, IEC60034-5, IEC61131-3
● Compatibility with both mechanical and electronic
● MIL STND 461
engines makes it versatile.
● True RMS sensing ensures AC metering accuracy
to within ± 1% of rated AC voltage (L-L and L-N)
and current. STANDARD FEATURES
● kW and kVA metering to within ± 5% of rating
CONTROLS
● Three levels of security allow for configurable
● Auto/Start/Stop
operator privileges.
● Engine Cool-Down Timer
● Single, standard 70-pin connector
● Emergency Stop
● Engine Cycle Cranking
COMMUNICATION
● Lamp Test
● J1939 (Primary Data Link) ● Generator Voltage
● J1939 #2 (Accessory Data Link) ● Engine Speed/Generator Frequency
● MODBUS RTU (1/2 duplex); RS-485 (Electronic Engines Only)
(Customer Communication) DIGITAL (LCD) INDICATION
● Generator AC Voltage – 3 phase (L-L and L-N)
● Generator AC Current (per phase and average)
ENVIRONMENTAL SPECIFICATIONS ● Generator Power (kW) (total and per phase)
● Environmentally sealed front face rated for IP56. ● Generator kVAR (total and per phase)
Resistant to chemical splash, including: diesel ● Generator kVAR-hr (total)
fuel, engine oil and machine oil. ● Generator % of rated power (total)
● Protection level IP22 for rear of controller (kW, kWA, kVAR)
● Resistant to salt spray ● Generator kVA (total and per phase)
● Vibration: withstands 4.3G @ 24-1000 Hz ● Generator kW-hr (total)
● Shock: withstands 15G ● Generator Power Factor (PF)
● Monitoring Functionality and Controls Operational (average and per phase)
from –40° C to 70° C (–40° F to 158° F) ● Generator Frequency
● Display Operational from –20° C to 70° C (–4° F ● Engine RPM
to 158° F) ● Battery Voltage
● Storable from –40° C to 85° C (–40° F to 185° F) ● Engine Hours
● 0 to 95% Humidity, non-condensing from 30° C ● Engine Successful Start Counter
to 60° C (86° F to 140° F) ● Engine Oil Pressure
● Engine Coolant Temperature
● Engine Crank Attempt Counter
● Service Maintenance Interval (Engine
Operating Hours or Calendar Days)
● Real Time Clock
● Twenty (20) Event Fault Log

LEHE4748-02 2

2
EMCP 3.3
GENERATOR SET CONTROLLER

STANDARD FEATURES (CONT’D)


Also available with Electronic Engines*: DIGITAL INPUTS (8 TOTAL)
● Air Filter Differential Pressure ● Emergency Stop
● Boost Pressure ● Remote Start
● Engine Crankcase Pressure ● 6 Programmable
● Engine Exhaust Temperature (L & R) Digital inputs can be programmed for various alarm,
● Engine Intake Manifold Temperature shutdown, and status conditions including:
● Engine Oil Temperature ● Low Fuel Level
● Fuel Consumption (US/Imperial gal/hr or Liters/hr) ● High Fuel Level
● Fuel Filter Differential Pressure ● Fuel Leak Detected
● Fuel Pressure ● High Exhaust Temperature
● Oil Filter Differential Pressure ● Air Damper Closed
● Oil Temperature ● Circuit Breaker Open/Closed
● Total Fuel Consumed ● Low Engine Oil Level
● Low Coolant Level
Notes: ● Low Starting Air Pressure
1. Temperature indications are viewable in either ● Low/High Ambient Air Temperature
°C or °F (operator selectable) ● Spare Fault #1-6
2. Pressure indications are viewable in psi, kPa, Inputs can be programmed for either high or low
or bar activation using programmable Normally Open
3. Fuel Consumption viewable in US/Imperial or Normally Closed contacts.
gal/hr or Liters/hr
Note: The number of programmable Digital Inputs
WARNING/SHUTDOWN INDICATION may vary based on specific package configuration.
● Overcrank Refer to Engine Installation Guide for specific
● Low Coolant Temperature Warning engine application.
● High Coolant Temperature Warning/Shutdown
PROTECTIVE RELAYING
● Loss of Coolant Warning/Shutdown
● Generator Over/Under Voltage
● Low Oil Pressure Warning/Shutdown
● Generator Over/Under Frequency
● Overspeed
● Generator Reverse Power
● Control Switch Not In Auto
● Generator Overcurrent
● High/Low Battery Voltage
● Emergency Stop Activated RELAY OUTPUTS (8 TOTAL)
● Starter Motor
Also available with Electronic Engines*:
● Fuel Control
● Low Fuel Pressure Warning/Shutdown
● 6 Programmable
● High Fuel Pressure Warning/Shutdown
● Fuel Filter Restriction Warning/Shutdown Relay outputs can be programmed for various
● High Intake Manifold Air Temperature operating conditions including: Air Shut-off, or
Warning/Shutdown Pre-lube, Common Alarm, Common Shutdown,
● High Oil Temperature Warning/Shutdown Common Warning, Engine Running, Crank Alert,
Notes: and Idle/Rated.
● Warning condition activates common alarm Relays are rated for 2A @ 30 VDC and consist of
output signal and common flashing yellow 6 Form A (Normally Open) contacts. Two of the
indicating lamp. programmable outputs are Form C (Normally
● Shutdown condition activates common alarm Open and Normally Closed) contacts.
output signal and common flashing red Notes:
indicating lamp. 1. These are only rated for DC.
● Warning/Shutdown conditions result in text 2. The number of programmable Relay Outputs
message on EMCP 3 display. may vary based on specific package configuration.
* Engine information obtained from electronic engine controller Refer to Engine Installation Guide for specific
over J1939 data link when available. Refer to Engine Installation
Guide for specific engine application. engine application.

LEHE4748-02 3
EMCP 3.3
GENERATOR SET CONTROLLER

STANDARD FEATURES (CONT’D) EMCP 3.3 GENSET CONTROLLER


DISCRETE OUTPUTS (2 TOTAL) 308 mm
● 2 Programmable
Discrete outputs can be programmed for various
operating conditions including: Air Shut-off,
Pre-lube, Common Alarm, Common Shutdown,
Common Warning, Engine Running, Crank Alert,
and Idle/Rated.
Discrete outputs can sink up to 300mA and are 247 mm
suitable for driving relay coils or incandescent
lamps.
SENSOR INPUTS
● Engine Speed (Magnetic Pick-up)
● Engine Oil Pressure (0-2 k Ω resistive sender,
1 or 2-wire) – MUI Engines only
● Engine Coolant Temperature (0-2 k Ω resistive
sender, 1 or 2-wire) – MUI Engines only
● Configurable Input (0-2 k Ω resistive sender)
(for engine oil temperature, etc.) 57 mm

AVAILABLE LOCAL DISPLAY LANGUAGES

• Arabic • Italian
• Chinese • Japanese
• Czech • Latvian
• Danish • Lithuanian
• Dutch • Norwegian
• Estonian • Polish
• Finnish • Portuguese
• French • Russian
• German • Spanish
• Greek • Slovak
• Hungarian • Slovene
• Icelandic • Swedish
• Turkish
Note: Displays contain 2 languages
(English and Local)

LEHE4748-02 4
EMCP 3.3
GENERATOR SET CONTROLLER

OPTIONS

REMOTE MONITORING SOFTWARE


The EMCP 3 Remote Monitoring Software Package
is a PC based program which allows the user to
ANNUNCIATOR monitor and control a generator set, and is capable
The EMCP 3 Annunciator serves to display Genset of running on a Windows based operating system.
system alarm conditions and status indications. The Remote Monitoring software allows the user
The Annunciator has been designed for use on to configure data monitoring and data acquisition
the EMCP 3 Communication Network and may be processes for monitoring, graphing, and logging
used in either Local (package mounted) or Remote of genset data.
(up to 800 feet) application. A maximum of three (3)
Annunciators may be used with a single EMCP 3.3.

LEHE4748-02 5
EMCP 3.3
GENERATOR SET CONTROLLER

RTD MODULE
The RTD module serves to provide expandable
engine and generator temperature monitoring
capability of the EMCP 3 and is capable of reading
up to eight (8) type 2-wire, 3-wire and 4-wire RTD
inputs. The RTD Module has been designed for
use on the EMCP 3 Communication Network and
may be used in either Local (package mounted) or
Remote (up to 800 feet) application. A maximum
of one (1) RTD Module may be used with a single
EMCP 3.3.
THERMOCOUPLE MODULE
DISCRETE INPUT/OUTPUT MODULE The Thermocouple module serves to provide
expandable engine and generator temperature
The Discrete Input/Output (DI/O) module serves to
monitoring capability of the EMCP 3 and is
provide expandable Input and Output capability
capable of reading up to twenty (20) Type J
of the EMCP 3 and is capable of reading 12 discrete
or K Thermocouple inputs. The Thermocouple
inputs and setting 8 relay outputs. The DI/O
Module has been designed for use on the EMCP 3
Module has been designed for use on the J1939
Communication Network and may be used in either
Communication Network and may be used in
Local (package mounted) or Remote (up to 800 feet)
either Local (package mounted) or Remote
application. A maximum of two (2) Thermocouple
(up to 800 feet) application. A maximum of
Modules may be used with a single EMCP 3.3.
four (4) DI/O Modules may be used with a
single EMCP 3.3.

LEHE4748-02 6
EMCP 3.3
GENERATOR SET CONTROLLER

This page intentionally left blank.

LEHE4748-02 7
EMCP 3.3
GENERATOR SET CONTROLLER

This page intentionally left blank.

Information contained in this publication may be considered confidential. www.cat-ElectricPower.com


Discretion is recommended when distributing.
Materials and specifications are subject to change without notice. © 2005 Caterpillar
LEHE4748-02 (09-05) CAT, CATERPILLAR, their respective logos and “Caterpillar Yellow,” as well as corporate and product All Rights Reserved.
identity used herein, are trademarks of Caterpillar and may not be used without permission. Printed in U.S.A.

Você também pode gostar