Error
Code Description Solution
Fo Jeena seman aut ar ato ot modo and tat ye problem pats,
replace Main Control Board
[E11 | Checksum (intemal processor check) | Clear code, exit mode and stat dryer. If problem persists,
error replace Main Control Board
:12_| Non fatal reading or writing to the ‘Gear code, exit mode and start drver. If problem persists,
‘memory error replace Main Control Board
fear | Contiol nTC short circuit Measure resistance of control thermistor. If reading is not 50k
‘ohms (10%), replace thermistor. I reading is within 50k
‘ohms (210%), check wiring between the thermistor and Main
‘Contol Board. IF good, replace Main Control Board
fe2s | control wr open circurt Measure resistance of control thermistor. If reading is not 50k
‘ohms (10%), replace thermistor. If reading is within 5Ok
‘ohms (10%), check wiring between the thermistor and Main
‘Convo Board. If good, replace Main Contol Board
fest | Contact sensor frequency too high ‘Check the contact sensor and wing. If no problems ave found
swith contact sensor, replace Main Contol Board.
fe22 | Contact sonsor frequency too low ‘Check the contact sensor and wing. If no problems are found
with contact sensor, replace Main Contol Board.
fea2 | Deor sensing failure ‘Chock door switch and wiring, IFcomect, replace Main Control
Board.
fest | Motor ray faire ‘Tf motor runs continuously with power applied, check for short
crcuit across motor relay (RL2), oF L1 applied to motor relay
‘output (23-1) with cycle stoned. If motor does not start when.
‘Sart key is pressed, check for open circuit between Lt and
rotor relay connection (12-2). Ifno wiring problems found,
replace Main Control Board.
2
Motor fault- motor stopped or not
starting
Remove ary load from dryer and check if drum turns freely
by hand, Check L1 power supoly votage, motor windings,
and motor thermal protector (if motor thermal protector has
‘tipped, it may take up to 30 minutes to reset).
se
Motor centipetal swech fallure
‘Check wiring. Check ff motor centripetal switches are stuck in
‘open or closed positions. Repiace motor. Replace Main Control
Board.
es
Motor sensing failure
Replace Main Contiol Board.Error
Code Description Solution
fest | Heater relay failure, (Check for short circuit across heater ratay(s) (RLS, RL6, RL7)
or L1 applied to heater relay outnut(s) (5-2, 17-1, 17-3) with
‘oye stoped. Check for open circuit between L1 and heater
relay connection(s) (05-1, 15-3, 7-2). IF no witing problems
are found, replace the Main Control Board.
less | Heater to eath ground (Check heater coils and connections for short circuits to the
‘cbinet. Reslace heater and/or wirna and retest
lesa | Heater open circuit (Check heater coils and connections for open circuits, Replace
heater andjor wiring and retest.
less | High limit thermostat trip count too For electric model, check inlet therrral imier for continuity. IF
high
‘thermal imteris open, check for evidence of hich temperature
‘event ard any resulting damage. If no further damage is
‘evident, replace thermal miter. IF no problems are found
with the thermal limiter, chack exhaust vent system for air
blockages. If no problems with vent restictions, check/replace
high ime thermostat, and retest.
Thermal mer open circutt
‘Check outlet thermal limiter for contnutty. For g3s model, also
‘check inlet thermal miter for contnutty. If thermal lmter is
‘open, check for evidence of high temperature event ard any
resulting damage. If no further damage Is evident, replace
thermal limter and retest.
ks7
Heaters sensing faiure
(Check heater end wiring. If correct, replace Main Contol
Board.
Koy( button) stuck fault
Enter function test mode and perform key test to determine:
‘which button is at fault. Free the key(button) and perform test
‘again. If key stuck code stil exist, replace Main Control Board
utlet control thermistor open circuit
‘Check resistance of eutlet control thermistor, and check wiring
for open circuit. Resistanco should be botwoon 4.9K ohms and
{6.2K ohms at room temperature (68-77°F or 20-25°c). Replace
‘outlet control thermistor and/or wiring and retest.
Outlet control thermistor short circuit
‘Check resistance of cutlet control thermistor, and check wiring
for short circuit across thermistor connections. Resistance
‘should be between 4.9K ohms and 6.2K ohms at room
‘temperature (68-77% ar 20-25°c). Replace outlet control
thermistor and/or wiring and retest.
Inlet control thermistor open circuit
(Check resistance of inlet contro thermistor, and check wiring
for open circuit. Resistance should be between 47k ohms and
‘66k chm at room temperature (68-77°F oF 20-25%). Replace
inl control thermistor and/or wiring and retest.Error
Code Description Solution
le74 | Inlet contol thermister short crcut | Check resistance of inlet control thermistor, and check wiring
for short circuit across thermistor connections. Resistance
should be between 47k ohms and 66k ohms at room
temperature (68-77°F of 20-25%). Replace inlet contol
thermistor and/or wiring and retest.
lear | Communication error (Check connections between Main Control Board and User
Interface Board. In wiring problems, replace Main Control
Board or User Interface Board,
les2 | ancompatible protocol (Check if correct User Interface Boar and Main Cortrol Board
are installed, Replace appropriate hardware.
leas | machine configuration checksum error | Check ifcomect User Interface Board and console are installed.
Replace User Interface Board andor console.
leoa | cycle configuration checksum error Replace Main Control Board.
le27_ | Program mismatch Replace Main Control Board.
lear | Main supply freauency out of range Check frequency of Ine voltage.
lex2 | Vottage too high Check amplitude of line voltage,
leas | Voltage too low (Check amplitude of line votace.
les4 | improper home wiring (Check wiring at terminal block for LI-N-L2 wired incorrectly.
leas | Main Vottage sensing failure Replace Main Control Board.
le. | vent biockea (Check vent restrictions and resistance values of exaust control
thermistor and inl control thermistor.
les | max timeout timer (Check ventrestiction, contact sensor, and resistance values of
‘exaust control thermistor and inet control thermistor.
les | Key stuck ‘check buttons for activation wen pressed. Replace console oF
User Interface Board as appropriate
lesa | Program timeout foul (Check for anything that would exterd dry times such 25: no
(max. time oxceoded for that cycle) heat, restricted vent, bower fan blade broken or loose, dryer
intalledin closet with solid door, bad connection in moisture
‘sensor bar circuit or dirty tare-if dryer operates normally and
code returns, replace Main Control Board
[eB
Hester fault temperature reading of
the contra thermistor has not changed
ina set amount of time
(Check heater relay on Main Control Board, thermostats in
heater circuit, heater, and cortrol thermistorError
Code Description Solution
Esc [Tooman tine ofthe sty Check for Backed In er, locked exhaust, a eis around
thermostat in 2 period oF time air duct, broken or clogged fan blades, wom or loose drum
‘seals, and doar seal
E98 | External EEPROM communication or Replace User Interface Board.
data comuption
F2€__| Low or intermittent voltage to board | House wiring/ power supply problem
Ear | watchdog reset (Char code, exit mode and stat dryer. IF problem persists,
replace Main Control Board