Run Name: Alternative +0 rotation

Energy and Carbon US EPA Energy Water Photovoltaic LEED 3D VRML Export and Download Design
Weather
Results Star Usage Analysis Daylight View Data Files Alternatives

LEED Daylight * Update your glass performance using Design Alternatives.

Percentage of building area with glazing factor over 2%: 72.0% - No LEED Credit
LEED requires your project achieve a minimum glazing factor of 2% in a minimum of 75% of all regularly occupied areas.

LEED Daylight Space Analysis


Sidelighting Toplighting Toplighting Toplighting
Sidelighting Daylight Glazing Sawtooth Monitor Vertical Monitor Horizontal Skylight
Vision Glazing
Space Type Space Glazing
Space ID Area (ft²) Area (ft²) VT Area (ft²) VT Area (ft²) VT Area (ft²) VT Area (ft²) VT Factor

sp-102-Corridor Unspecified 568 243 0.68 425 0.68 0 N/A 0 N/A 0 N/A 16%

sp-101-Reception Unspecified 508 72 0.68 268 0.68 43 0.50 0 N/A 0 N/A 12.6%

sp-201-Corridor Unspecified 506 20 0.68 12 0.68 0 N/A 0 N/A 0 N/A 0.9%

sp-103-Corridor Unspecified 488 20 0.68 0 N/A 0 N/A 0 N/A 0 N/A 0.6%

sp-202-
Unspecified 407 100 0.68 24 0.68 0 N/A 0 N/A 0 N/A 4.1%
Conference_Room

sp-110-
Unspecified 407 92 0.68 0 N/A 0 N/A 0 N/A 0 N/A 3.1%
Conference_Room

sp-205-Office Unspecified 165 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-113-Office Unspecified 165 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-203-Office Unspecified 165 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-111-Office Unspecified 165 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-108-Office Unspecified 164 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-206-Office Unspecified 163 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-114-Office Unspecified 163 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-112-Office Unspecified 163 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-204-Office Unspecified 163 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-109-Office Unspecified 163 27 0.68 3 0.68 0 N/A 0 N/A 0 N/A 2.5%

sp-105-Men Unspecified 150 0 N/A 0 N/A 0 N/A 0 N/A 0 N/A 0%

sp-106-Women Unspecified 150 0 N/A 0 N/A 0 N/A 0 N/A 0 N/A 0%

sp-104-Stair Unspecified 146 94 0.68 74 0.68 0 N/A 5 0.68 0 N/A 16.8%

sp-107-Break_Rm Unspecified 138 12 0.68 0 N/A 0 N/A 0 N/A 0 N/A 1.2%

Note: Please refer to U.S. Green Building Council LEED Credit 8.1 documentation for more information (www.usgbc.org).