Data Center Thermal Assessment (DCTA)

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com
Data Center Thermal Assessment (DCTA)

Case Study: Problem Statement


. To study the Effectiveness of Cooling System
in the Data Center .
. To improve the efficiency of the Data Center.

Approach
. Establish the Flow-field and Thermal-interactions
through CFD Simulations
. Identify the regions of By-pass, Re-circulation &
Hot-spots
. Optimize the Containment-strategy for both Hot
and Cold Aisles through multiple CFD Iterations.
. Obtain the most efficient Cooling System for the
Data Center

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com
Data Center Thermal Assessment (DCTA)
Server Board &
Components

Model Geometry
Model Details

1. This case study involves a Data Center of System Geometry


8 Servers-racks in 4 x 4m room.

2. Each Server-rack consists of 42U with CPUs, memory


and motherboard components of known Heat Dissipation
Rate.

3. Each Server has a set of fans of known flow-rate (CFM)


which would force air to flow within the System over
the surface of the components to provide cooling.
Server Rack Geometry

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com
Data Center Thermal Assessment (DCTA)

Air-Domain Geometry

CFD Model of Data Center

Detailed Thermal & Flow Boundaries

Advanced Hex-Mesh with 2.5 M cells

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com
Data Center Thermal Assessment (DCTA)

System-level Analysis

Flow & Thermal Mapping of the Server


. Flow patterns simulated.
. Thermal interactions established.
. Hot-spots identified.
. Thermal loads and pressure gradients
0.042841 1.1517
Velocity: Magnitude (m/s)
2.2606 3.3695 4.4784 5.5873
necessary for effective cooling estimated.

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com
Data Center Thermal Assessment (DCTA)

Room-level Analysis – Flow Optimization

Flow Mapping using CFD

. Flow patterns simulated for the


Baseline model using CFD.

. Bye-pass and Re-circulation regions


identified.

Optimization of Flow
. Flow patterns simulated.
. Thermal interactions established.
. Hot-spots identified. Result: Flow patterns in data center
. Thermal loads and pressure gradients optimized through iterative CFD runs.

necessary for effective cooling estimated.

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com
Data Center Thermal Assessment (DCTA)

Room-level Analysis – Thermal Optimization

Thermal Mapping using CFD


. Hot-spots identified through CFD Analysis.
. Regions prone to thermal-losses identified.
. PUE and DCE obtained for the baseline
and optimized models.

Optimization of Flow
. Thermal-losses minimized.
. Hot-spots eliminated
Result: Result: Flow & Thermal optimization achieved.

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com
Data Center Thermal Assessment (DCTA)

Benefits

. Maximize . Optimize
- Uptime & Efficiency - Cooling Infrastructure

. Minimize . Identify
- Utilization of Power - Hot-Spots
- CAPEX & OPEX - Sources of Downtime

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com
Data Center Thermal Assessment (DCTA)

Conclusion

Through CFD Analysis of the Data Center


ü
14% Energy savings achieved.
ü
OPEX minimized.

)
+91 7760 854854 / 9916 296131 | Email: info@fexilon.com | www.fexilon.com