Rupture Disc Calculation Sheet

General
Name Tag Number Engineer Last Revised EXXON DISK 465 Pablo Sosa 2/17/2011 1:02:45 PM

Design Basis
Code Purpose Case Vessel/System MAWP Overpressure Allowance Discharge Coefficient Fluid State Required Capacity API RP520 Primary Tube rupture 1.95 barg 3 psi 0.62 Vapor 27,280.000 kg/hr

Fluid Properties
Fluid Ratio of Specific Heats Molecular Weight Density Compressibility 1 Air 1.401 28.966

Specifications
Specified Burst Pressure Relieving Temperature Superimposed Exit Pressure Notes 1.95 barg 30 C

Calculations
Calculated Area Calculated Capacity Recommended Nominal Disc Size Minimum Net Flow Area Calculated Reaction Force Flow Type Kd Capacity Formula
Notice: Calculation result is based on the conditions specifically applicable to the Kd method.

25.712 in2 45,940.887 kg/hr 8 in 43.3 in2 2,142.062 lbf Critical