Você está na página 1de 2

XG Category 6a F/UTP Cable Cut Sheet

1499389-X, 1499416-X

Ripcord (under jacket)

Jacket

Drain Wire

Foil Shield

Polyester Film

Insulation Filler Conductor

Description
AMP NETCONNECT Category 6a F/UTP cables meet or exceed channel specifications of ANSI/TIA/EIA-568-C Category 6a and ISO/IEC 11801:2002/Amd 1:2008 Class EA up to 500 MHz when used as a component in a properly installed AMP NETCONNECT XG F/UTP channel. The AMP NETCONNECT XG Category 6a F/UTP System complies with all of the performance requirements for current and proposed applications such as Gigabit Ethernet (1000BASE-Tx), 10/100BASE-Tx, token ring, 155 Mbps ATM, 100 Mbps TP-PMD, ISDN, analog and digital video, analog and digital voice (VoIP), and exceeds all requirements for IEEE 802.3an 10 Gigabit Ethernet on all parameters. AMP NETCONNECT XG Category 6a F/UTP cables are available in both plenum and non-plenum, and are packaged in bulk on wooden reels. Standard jacket colors are white, gray, blue and yellow.

Specification (text in brackets [ ] requires a choice)


Horizontal cabling shall be 23 AWG, 4-pair FTP, NEC/NFPA [CMP or CMR] rated and shall be independently tested for compliance. Cable jacketing shall be [white, gray, blue or yellow (if plenum) or white (if non-plenum)]. Cable shall meet all the requirements of EIA/TIA-568-C as well as the performance requirements listed in the following table: [include Channel Performance Characteristics tables from page 2]. Cable shall be independently tested for performance to the following specifications: 1. ANSI/TIA/EIA-568-B.2-10:2008 2. ISO/IEC 11801:2002/Amd 1:2008 3. IEEE 802.3an Independent verification for flammability compliance shall be to NEC article 800 and NFPA 70; [CMP (NFPA 262, UL 910) or CMR (ANSI/UL 1581, CSA C22.2)]. Cable shall be supplied on wooden reels. Horizontal cable shall be AMP NETCONNECT part number [1499389-X or 1499416-X (X denotes jacket color)]. Part Number
Description AMP NETCONNECT XG Category 6a F/UTP Cable, 4-Pair X denotes jacket color: 4- -1 = White, 4- -3 = Gray, 4- -5 = Blue, 4- -7 = Yellow Copyright 2008 by Tyco Electronics Corporation. All Rights Reserved. AMP, AMP NETCONNECT, NETCONNECT, and Tyco are trademarks. Specifications subject to change without notice. UL/NEC Rating CMR CMP Packaging 1000ft (305m) WR 1000ft (305m) WR Part Numbers 1499389-X 1499416-X

XG Category 6a F/UTP Cable Cut Sheet


1499389-X, 1499416-X
Channel Performance Characteristics (meet or exceed ANSI/EIA/TIA, ISO/IEC and IEEE requirements)

ELTCL / TCTL (dB)

Return Loss (dB)

0.772 1 4 8 10 16 20 25 31.25 62.5 100 200 250 300 400 500

2.1 2.3 4.2 5.8 6.5 8.2 9.2 10.2 11.5 16.4 20.9 30.1 33.9 37.4 43.6 49.3

65.0 65.0 63.0 58.2 56.6 53.2 51.6 50.0 48.4 43.4 39.9 34.8 33.1 31.7 28.7 26.1

62.0 62.0 60.5 55.6 54.0 50.6 49.0 47.3 45.7 40.6 37.1 31.9 30.2 28.8 25.8 23.2

65.5 63.3 51.2 45.2 43.3 39.2 37.2 35.3 33.4 27.3 23.3 17.2 15.3 13.7 11.2 9.28

62.5 60.3 48.2 42.2 40.3 36.2 34.2 32.3 30.4 24.3 20.3 14.2 12.3 10.7 8.2 6.3

19.0 19.0 19.0 19.0 19.0 18.0 17.5 17.0 16.5 14.0 12.0 9.0 8.0 7.2 6 6

585.0 580.0 562.0 556.7 555.4 553.0 552.0 551.2 550.4 548.6 547.6 546.5 546.3 546.1 545.8 545.6

50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50 50

40.0 40.0 40.0 39.5 38.0 34.9 33.5 32.0 30.4 24.4 20.3 14.3 12.3 10.8 8.3 6.3

32.2 30.0 18.0 11.9 10.0 5.9 4.0 2.0 N/A N/A N/A N/A N/A N/A N/A N/A

67.0 67.0 67.0 67.0 67.0 67.0 67.0 66.0 65.1 62.0 60.0 55.5 54.0 52.8 51.0 49.5

Technical Details
Mutual Capacitance Characteristic Impedance Conductor DC Resistance Voltage Nominal Velocity of Propagation Operating Temperature Bend Radius Conductors Insulation Materials: Jacket Filler Safety Approvals: Performance CMR 5.6 nF/100 m nominal 100 , 1 - 500 MHZ 20.3 /mft maximum @ 20 C 300 VRMS 72% -20 C 60 C (-4 F 140 F) (4 cable diameter) 2 23 AWG, Solid Copper, (.0225 .0001) 0.010 in (.044 .001), Polyethylene 0.022 in nominal (.300 nominal), PVC FEP ETL LISTED for safety: CMR (UL 1666, IEC 332-1) CMP (NFPA 262, UL 910) ETL Tested to: Channel specifications of TIA/EIA-568-C CMP 5.6 nF/100 m nominal 100 15%, 1 - 250 MHZ 20.3 /mft maximum @ 20 C 300 VRMS 72% -10 C 60 C (-4 F 140 F) (4 cable diameter) 2 23 AWG, Solid Copper, (.0225 .0001) 0.0110 in (.044 .001), FEP 0.018 in nominal (.300 nominal), FR PVC FEP

In the U.S.A 1-800-553-0938 Last Updated - 11/19/2008 Canada 905-475-6222 Mexico 525-729-0400 South and Central Americas 54-11-4733-2200 web: http://www.ampnetconnect.com/ e-mail: networking.help@tycoelectronis.com Copyright 2008 by Tyco Electronics Corporation. All Rights Reserved. AMP, AMP NETCONNECT, NETCONNECT, and Tyco are trademarks. Specifications subject to change without notice.

PSAACRF / PSAFEXT (dB) 67.0 67.0 65.0 58.9 57.0 52.9 51.0 49.0 47.1 41.1 37.0 31.0 29.0 27.5 24.9 23.0

Prop Delay (ns/100m)

Prop Delay Skew (ns)

Frequency (MHz)

PSANEXT (dB)

Insertion Loss (dB)

PSACRF (dB)

PSNEXT (dB)

ACRF (dB)

NEXT (dB)

TCL (dB)

Você também pode gostar