Catalog HY10-1630/US

Piston Accumulators Series 3000

Series 3000 Piston Accumulators


Heavy Duty Service with 3000 PSI Operating Pressure 2" thru 12" Bores with Over 50 Standard Capacities Patented V-O-ring Piston Seals Serviceable Threaded End Construction Five Standard Seal Options to Handle a Variety of Fluids and Temperatures ASME Certification and CE Marking Available

22

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Specifications Materials
Shell high strength alloy steel Caps steel Pistons aluminum (2" thru 8"), ductile iron (9" & 12") Gas Valve Cartridge steel Gas Valve Protector steel Piston Glide Rings PTFE Piston & End Seals various polymers Piston Seal Backups PTFE

Piston Accumulators Series 3000 Standard Ports


The following ports are supplied as standard on all fluid ends and on the gas end of accumulators ordered for use with gas bottles:
Notes: 1) For flange dimensions, see tables below. 2) On standard 7", 8" & 9" bore accumulators, both SAE Straight Thread and Flange ports are available as standard. Omit port code for SAE #32 Straight Thread, specify PL port code for 2" Code 61 Flange when ordering. Flange ports are recommended at operating pressures above 2000 PSI due to pressure limitations of most #32 SAE Straight Thread fittings. Standard Ports Standard Models Metric Models BSPP Metric SAE SAE Port SAE Flange1 Port (in) Flange1 #12 3/4 #12 1 #20 1 #24 1-1/2 #32 2" Code 61 2" Code 61 #32 2" Code 61 2" Code 61 #32 2" Code 61 2" Code 61 3" Code 61 3" Code 61

Actual Bore Sizes & Maximum Flow Rates Pressure Ratings


Nominal Bore Size (in.) 2 3 4 6 7 8 9 12 Actual Bore Size (in.) (mm) 2.02 51.44 3.00 76.20 4.03 102.4 5.78 146.9 7.00 177.8 7.87 200 9.00 228.6 11.88 301.6 Max. Recommended Flow* GPM LPM 100 380 220 834 397 1504 818 3096 1199 4538 1199 4538 1982 7502 3450 13061

Bore Size 2 3 4 6 7 8 9 12

*Note: Based on 120 in/sec maximum piston speed, port & fitting size will become limiting factors for most applications.

1) See flange dimensions in Port Options.

Gas Valves
Parker Series 3000 piston accumulators are rated at 3000 psi and a minimum 4 to 1 design factor. For pressures over 3000 psi, see Series 4000 and Series 5000 accumulators. Two types of gas valves are available on Series 3000 piston accumulators and gas bottles. Units with 2" thru 6" bores, are offered with a cored gas valve cartridge (ISO-4570-8V1) as standard. All 7" thru 12" bore units are supplied with a heavy duty (military) poppet-type gas valve cartridge (MS28889-2) as standard.
Note: The Parker standard gas cap will accept either style gas valve.

Fluids
Parkers piston accumulators are compatible with a wide variety of fluids. Standard accumulators (with nitrile seals) may be used with petroleum-based industrial oils or water-based flame resistant fluids. Optional seals compatible with most industrial fluids are available with temperature ranges from -45F to 325F (-43C to 162C).

Precharge
Units are shipped with a nominal nitrogen precharge as standard. For specific precharge pressures, specify at the time of order.
#5 SAE THREAD 1/220 UNF-2A
1/220 UNF-2A

Auxiliary Gas Bottles


When space does not permit the installation of the required piston accumulator, a smaller accumulator may be used by connecting it to an auxiliary gas bottle(s) that can be located in a nearby spot where space is available. In some cases, a piston accumulator and gas bottle combination may be more economical, especially large capacity sizes. Piston travel, confined to the accumulator, must be calculated with ample margins to store the required fluid.

Available Options
If your application requires a piston accumulator, gas bottle, or special option that falls outside of Parkers broad offering, consult your local distributor, Parker representative, or the factory with your specific requirements. Parker has the manufacturing and engineering expertise to design and build piston accumulators to your exacting requirements, from simple modifications of standard units to complete designs. Some example of Parkers past special designs include: Special and Stainless Steel Materials Piston Position and Velocity Sensors and Switches Water Service Non-Standard Capacities
Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

23

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Small Bore

3000 PSI Piston Accumulators for Oil and Water Service


3 Mounting Holes E Thread G Depth Cored Gas Valve (see note)

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No.1 Oil Service A2N0005D1K A2N0010D1K A2N0015D1K A2N0029D1K A2N0058D1K A3N0029D1K A3N0058D1K A3N0090D1K A3N0116D1K A3N0183D1K A4N0058D1K A4N0116D1K A4N0231D1K A4N0347D1K A4N0578D1K A6N0231D1K A6N0347D1K A6N0578D1K A6N0924D1K A6N1155D1K A6N1733D1K A6N2310D1K

Fluid Volume (gal) 1 Pint 1 Quart 1 Pint 1 Quart 1.5 Liter 1/2 Gal. 3 Liter 1 Quart 1/2 Gal. 1 Gal. 1-1/2 Gal. 2-1/2 Gal. 1 Gal. 1-1/2 Gal. 2-1/2 Gal. 4 Gal. 5 Gal. 7-1/2 Gal. 10 Gal. (cu in) 5 10 15 29 58 29 58 90 116 183 58 116 231 347 578 231 347 578 924 1155 1733 2310

Gas Volume (cu in) 6 11 16 30 59 34 63 95 121 188 68 126 241 357 588 266 382 613 959 1190 1768 2345

D-Hydraulic Port A (in) B (in) 6.76 8.31 9.78 14.19 23.19 10.25 14.34 18.94 22.56 32.06 11.63 16.19 25.19 34.31 52.38 17.38 21.81 30.63 43.81 52.63 74.63 96.63 C (in) SAE No. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 5 5 6 7 10 14 18 22 25 32 29 35 48 61 87 83 97 124 165 192 260 327

2.38

1.06

12

1-1/16 - 12

3/4

3.56

1.13

12

1-1/16 - 12

3/4

3/8 - 24

2.25

0.56

4.75

1.13

20

1-5/8 - 12

1-1/4 1/2 - 20

3.25

0.75

6.88

1.13

24

1-7/8 - 12

1-1/2 1/2 - 20

4.38

0.75

Notes: 1) For Water Service add W after construction code, see How to Order information. 2) See Port Options for complete listing of optional ports. 3) ASME Certified and CE marked accumulators and gas bottles are available. 4) When accumulators are to be used with gas bottles, order Accumulators for Use with Gas Bottles." 5) 2", 3", 4" & 6" bores standard with cored gas valves. Poppet type (MS28889-2) gas valve available as an option.

24

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Small Bore

3000 PSI Accumulators for Use with Gas Bottles


Typical Both Ends
3 Mounting Holes E Thread G Depth D Gas Port

F Dia. Bolt Circle

Threaded Port Configuration

Flange Port Configuration

D Hydraulic Port

Accumulator Model No. A4N0058D3KTFTF A4N0116D3KTFTF A4N0231D3KTFTF A4N0347D3KTFTF A4N0578D3KTFTF A6N0231D3KTGTG A6N0347D3KTGTG A6N0578D3KTGTG A6N0924D3KTGTG A6N1155D3KTGTG A6N1733D3KTGTG A6N2310D3KTGTG

Fluid Volume (gal) 1 Quart 1/2 Gal. 1 Gal. 1-1/2 Gal. 2-1/2 Gal. 1 Gal. 1-1/2 Gal. 2-1/2 Gal. 4 Gal. 5 Gal. 7-1/2 Gal. 10 Gal. (cu in) 58 116 231 347 578 231 347 578 924 1155 1733 2310

Gas Volume (cu in) 68 126 241 357 588 266 382 613 959 1190 1768 2345

D Port (Both Ends) A (in) B (in) 10.50 15.06 24.06 33.19 51.25 16.25 20.68 29.50 42.68 51.50 73.50 95.50 SAE No. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 29 35 48 61 87 83 97 124 165 192 260 327

4.75

20

1-5/8 - 12

1-1/4

1/2 - 20

3.25

0.75

6.88

24

1-7/8 - 12

1-1/2

1/2 - 20

4.38

0.75

3000 PSI Auxiliary Gas Bottles


3 Mounting Holes E Thread G Depth Gas Valve Type (see note)

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No. Gas Bottle B4N0058D1K B4N0116D1K B4N0231D1K B4N0347D1K B4N0578D1K B6N0231D1K B6N0347D1K B6N0578D1K B6N0924D1K B6N1155D1K B6N1733D1K B6N2310D1K

Gas Volume Nominal (gal) 1 Quart 1/2 Gal. 1 Gal. 1-1/2 Gal. 2-1/2 Gal. 1 Gal. 1-1/2 Gal. 2-1/2 Gal. 4 Gal. 5 Gal. 7-1/2 Gal. 10 Gal. Actual (cu in) 86 144 259 375 606 319 435 666 1012 1243 1821 2398 A (in) B (in) 11.63 16.19 25.19 34.31 52.38 17.38 21.81 30.63 43.81 52.63 74.63 96.63 C (in) SAE No.

D Port Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 27 33 46 59 85 68 82 111 154 182 254 325

4.75

1.13

20

1-5/8 - 12

1-1/4

1/2 - 20

3.25

0.75

6.88

1.13

24

1-7/8 - 12

1-1/2

1/2 - 20

4.38

0.75

25

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Small Bore

207 Bar Metric Accumulators for Oil and Water Service


3 Mounting Holes E Thread G Depth Cored Gas Valve (see note)

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No.1 Oil Service A2N0005D2K A2N0010D2K A2N0015D2K A2N0029D2K A2N0058D2K A3N0029D2K A3N0058D2K A3N0090D2K A3N0116D2K A3N0183D2K A4N0058D2K A4N0116D2K A4N0231D2K A4N0347D2K A4N0578D2K A6N0231D2K A6N0347D2K A6N0578D2K A6N0924D2K A6N1155D2K A6N1733D2K A6N2310D2K

Fluid Volume (Liters) 0.08 0.16 0.25 0.48 0.95 0.48 0.95 1.47 1.90 3.00 0.95 1.90 3.79 5.69 9.47 3.79 5.69 9.47 15.1 18.9 28.4 37.9 (cu in) 5 10 15 29 58 29 58 90 116 183 58 116 231 347 578 231 347 578 924 1155 1733 2310

Gas Volume (Liters) 0.11 0.19 0.24 0.50 0.98 0.56 1.03 1.56 1.98 3.08 1.11 2.06 3.95 5.85 9.64 4.36 6.26 10.0 15.7 19.5 29.0 38.4

D-Hydraulic Port A (mm) B (mm) 172 211 250 360 589 260 364 481 573 814 295 411 640 871 1330 441 554 778 1113 1337 1896 2454 C (mm) BSPP/G (in) SAE Flange E (mm) F (mm) G Weight (mm) (Kg) 2.1 2.3 2.6 3.3 4.7 6.5 8.1 9.8 11.1 14.6 13.0 15.9 21.8 27.6 39.3 37.8 44.0 56.3 74.7 87.0 117.8 148.5

60

27

3/4

90

29

M10

60

15

121

29

M12

82

18

175

29

1-1/2

M12

110

18

Notes: 1) 2) 3) 4) 5) For Water Service add W after construction code, see How to Order information. See Port Options for complete listing of port options. ASME Certified and CE marked accumulators and gas bottles are available. When accumulators are to be used with gas bottles, order "Accumulators for Use with Gas Bottles." 2", 3", 4" & 6" bores standard with cored gas valves. Poppet type (MS28889-2) gas valves available as an option.

26

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Small Bore

207 Bar Metric Accumulators for Use with Gas Bottles


Typical Both Ends
3 Mounting Holes E Thread G Depth D Gas Port

F Dia. Bolt Circle

Threaded Port Configuration

Flange Port Configuration

D Hydraulic Port

Accumulator Model No. A4N0058D2KRDRD A4N0116D2KRDRD A4N0231D2KRDRD A4N0347D2KRDRD A4N0578D2KRDRD A6N0231D2KRFRF A6N0347D2KRFRF A6N0578D2KRFRF A6N0924D2KRFRF A6N1155D2KRFRF A6N1733D2KRFRF A6N2310D2KRFRF

Fluid Volume (Liters) 0.95 1.90 3.79 5.69 9.47 3.79 5.69 9.47 15.1 18.9 28.4 37.9 (cu in) 58 116 231 347 578 231 347 578 924 1155 1733 2310

Gas Volume (Liters) 1.11 2.06 3.95 5.85 9.64 4.36 6.26 10.0 15.7 19.5 29.0 38.4

D - Port (Both Ends) A (mm) B (mm) 267 383 611 843 1302 413 525 749 1084 1308 1867 2426 BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 13 16 22 28 39 38 44 56 75 87 118 149

121

M12

82

18

175

1-1/2

M12

110

18

207 Bar Metric Auxiliary Gas Bottles


3 Mounting Holes E Thread G Depth Gas Valve Type (see note)

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No. Gas Bottle B4N0058D2K B4N0116D2K B4N0231D2K B4N0347D2K B4N0578D2K B6N0231D2K B6N0347D2K B6N0578D2K B6N0924D2K B6N1155D2K B6N1733D2K B6N2310D2K

Gas Volume Nominal (gal) 1 Quart 1/2 Gal. 1 Gal. 1-1/2 Gal. 2-1/2 Gal. 1 Gal. 1-1/2 Gal. 2-1/2 Gal. 4 Gal. 5 Gal. 7-1/2 Gal. 10 Gal. Actual (liters) 1.41 2.36 4.24 6.15 9.93 5.23 7.13 10.9 16.6 20.4 29.8 39.3 A (mm) B (mm) 295 411 640 871 1330 441 554 778 1113 1337 1896 2454 C (mm)

D-Hydraulic Port BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 12 15 21 27 39 36 42 54 72 85 116 146

121

29

M12

82

18

175

29

1-1/2

M12

110

18

27

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Large Bore

3000 PSI Piston Accumulators for Oil and Water Service

3 Mounting Holes E Thread G Depth

High Pressure MS28889-2 Gas Valve

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No.1 Oil Service A7K0578D3KPL A7K1155D3KPL A7K1733D3KPL A7K2310D3KPL A7K3465D3KPL A7K5775D3KPL A9K2310D3KPL A9K3465D3KPL A9K4620D3KPL A9K5775D3KPL A9K6930D3KPL A12K5775D1K A12K6930D1K A12K9240D1K A12K11550D1K

Fluid Volume (gal) 2-1/2 Gal 5 Gal. 7-1/2 Gal. 10 Gal. 15 Gal. 25 Gal. 10 Gal. 15 Gal. 20 Gal. 25 Gal. 30 Gal. 25 Gal. 30 Gal. 40 Gal. 50 Gal. (cu in) 578 1155 1733 2310 3465 5775 2310 3465 4620 5775 6930 5775 6930 9240 11550

Gas Volume (cu in) 633 1210 1788 2365 3520 5830 2400 3555 4710 5865 7020 5975 7130 9440 11750

D-Hydraulic Port A (in) B (in) 27.25 42.25 57.25 72.25 102.25 162.25 48.75 66.94 85.06 103.18 121.37 67.50 76.31 98.88 119.62 C (in) SAE No. 32 1.63 Thread Size (in) 2-1/2 - 12 or 2 Code 61 Flange (PL)2 32 1.63 2-1/2 - 12 or 2 Code 61 Flange (PL)2 3" SAE Flange Ports (Code 61) See Port Options for Dimensions 2 3/4 - 16 7.00 1.13 Tube Size 2 5/8 - 18 5.75 0.94 E (in) F (in) G (in) Weight (lbs) 170 226 283 340 454 682 595 758 920 1083 1246 1336 1490 1799 2108

8.13 0.06

11.02 0.09

14.41 0.09

1.63

7/8-9 (6X)

9.00

1.50

The Minimum Design Metal Temperature (MDMT) for ASME certified 7 and 9 piston accumulators presented in this section is 20F (-7C). The Minimum Design Metal Temperature (MDMT) for ASME certified 12 piston accumulators presented in this section is 32F (0C).

Notes: 1) For Water Service add W after construction code, see How to Order information. 2) Most SAE #32 fittings are rated for 2000 PSI. If 2000 to 3000 PSI service is required, two options are available; order accumulator with optional standard 2" SAE Code 61 4-bolt flange port by specifying PL code when ordering or order the accumulator with a SAE #24 port or smaller, see Port Options for dimensions and How to Order. 3) See Port Options for complete listing of optional ports. 4) ASME Certified and CE marked accumulators and gas bottles are available. 5) When accumulators are to be used with gas bottles, order Accumulators for Use with Gas Bottles. 6) Poppet type (MS28889-2) gas valve standard.

28

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Large Bore

3000 PSI Accumulators for Use with Gas Bottles


Typical Both Ends
3 Mounting Holes E Thread G Depth D Gas Port

F Dia. Bolt Circle

Threaded Port Configuration

Flange Port Configuration

D Hydraulic Port

Accumulator Model No. A7K0578D3KPLPL A7K1155D3KPLPL A7K1733D3KPLPL A7K2310D3KPLPL A7K3465D3KPLPL A9K2310D3KPLPL A9K3465D3KPLPL A9K4620D3KPLPL A9K5775D3KPLPL A9K6930D3KPLPL A12K5775D3KPNPN A12K6930D3KPNPN A12K9240D3KPNPN A12K11550D3KPNPN

Fluid Volume (gal) 2-1/2 Gal. 5 Gal. 7-1/2 Gal. 10 Gal. 15 Gal. 10 Gal. 15 Gal. 20 Gal. 25 Gal. 30 Gal. 25 Gal. 30 Gal. 40 Gal. 50 Gal. (cu in) 578 1155 1733 2310 3465 2310 3465 4620 5775 6930 5775 6930 9240 11550

Gas Volume (cu in) 633 1210 1788 2365 3520 2400 3555 4710 5865 7020 5975 7130 9440 11750

A (in)

B (in) 25.63 40.63 55.63 70.63 100.63 47.00 65.25 101.50 119.62 137.75 65.88 74.69 97.25 118.00

D Port (Both Ends)(in) 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread

E (in)

F (in)

G (lbs)

Weight 170 226 283 340 454 595 758 920 1083 1246 1336 1490 1799 2108

8.13 0.06

5/8 - 18

5.75

0.94

11.02 0.09

2" Code 61 Flange (PL)2 or #32 SAE Straight Thread 3" SAE Flange Ports (Code 61) See Port Options for Dimensions

3/4 - 16

7.00

1.13

14.41 0.09

7/8 - 9 (6X)

9.00

1.50

3000 PSI Auxiliary Gas Bottles


3 Mounting Holes E Thread G Depth High Pressure MS 28889-2 Gas Valve

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No. Gas Bottle B7K0578D3K(PL) B7K1155D3K(PL) B7K1733D3K(PL) B7K2310D3K(PL) B7K3465D3K(PL) B9K2310D3K(PL) B9K3465D3K(PL) B9K4620D3K(PL) B9K5775D3K(PL) B9K6930D3K(PL) B12K5775D1K B12K6930D1K B12K9240D1K B12K11550D1K

Gas Volume Nominal (gal) 2-1/2 Gal. 5 Gal. 7-1/2 Gal. 10 Gal. 15 Gal. 10 Gal. 15 Gal. 20 Gal. 25 Gal. 30 Gal. 25 Gal. 30 Gal. 40 Gal. 50 Gal. Actual (cu in) 677 1254 1832 2401 3556 2474 3629 4620 5775 6930 6288 7443 9783 12093 A (in) B (in) 27.25 42.25 57.25 72.25 102.25 48.75 66.94 85.06 103.25 121.37 67.50 76.31 98.88 119.62 C (in) D Port 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread E (in) F (in) G (in) Weight (lbs) 160 217 274 331 445 546 709 872 1035 1197 1246 1400 1709 2017

8.13 0.06

1.63

5/8 - 18

5.75

0.94

11.02 0.09

1.63

2" Code 61 Flange (PL)2 or #32 SAE Straight Thread 3" SAE Flange Ports (Code 61) See Port Options for Dimensions

3/4 - 16

7.00

1.13

14.41 0.09

1.63

7/8 - 9 (6X)

9.00

1.50

29

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Large Bore

207 Bar Metric Accumulators for Oil and Water Service

3 Mounting Holes E Thread G Depth

High Pressure MS28889-2 Gas Valve

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No.1 Oil Service A7K0578D2K A7K1155D2K A7K1733D2K A7K2310D2K A7K3465D2K A9K2310D2K A9K3465D2K A9K4620D2K A9K5775D2K A9K6930D2K A12K5775D2K A12K6930D2K A12K9240D2K A12K11550D2K

Fluid Volume (Liters) 9.47 18.9 28.4 37.9 56.8 37.9 56.8 75.7 94.7 113.6 94.6 114 151 189 (cu in) 578 1155 1733 2310 3465 2310 3465 4620 5775 6930 5775 6930 9240 11550

Gas Volume (Liters) 10.4 19.8 29.3 38.8 57.7 39.3 58.3 77.2 96.2 115.1 97.9 117 155 193

D-Hydraulic Port A (mm) B (mm) 692 1073 1454 1835 2597 1238 1700 2161 2622 3083 1715 1938 2512 3038 C (mm) BSPP/G (in) SAE Flange 2" Metric Code 61 Flange E (mm) F (mm) G Weight (mm) (Kg) 76.9 103 129 154 206 270 344 417 491 565 606 676 816 956

206.5 1.52

41

M16

150

24

279.9 2.29

41

2"Metric Code 61 Flange 3" Metric Code 61 Flange

M20

182

30

365.9 2.29

41

M20 (6X)

230

30

Notes: 1) For Water Service add W after construction code, see How to Order information. 2) Most SAE #32 fittings are rated for 2000 PSI. If 2000 to 3000 PSI service is required, two options are available; order accumulator with optional standard 2" SAE Code 61 4-bolt flange port by specifying PL code when ordering or order the accumulator with a SAE #24 port or smaller, see Port Options for dimensions and How to Order. 3) See Port Options for complete listing of optional ports. 4) ASME Certified and CE marked accumulators and gas bottles are available. 5) When accumulators are to be used with gas bottles, order Accumulators for Use with Gas Bottles. 6) Poppet type (MS28889-2) gas valve standard.

30

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Large Bore

207 Bar Metric Accumulators for Use with Gas Bottles


Typical Both Ends
3 Mounting Holes E Thread G Depth D Gas Port

F Dia. Bolt Circle

Threaded Port Configuration

Flange Port Configuration

D Hydraulic Port

Accumulator Model No. A7K0578D2KMLML A7K1155D2KMLML A7K1733D2KMLML A7K2310D2KMLML A7K3465D2KMLML A9K2310D2KMLML A9K3465D2KMLML A9K4620D2KMLML A9K3465D2KMLML A9K4620D2KMLML A12K5775D2KMNMN A12K6930D2KMNMN A12K9240D2KMNMN A12K11550D2KMNMN

Fluid Volume (Liters) 9.47 18.9 28.4 37.9 56.8 37.9 56.8 75.7 94.6 113.6 94.6 114 151 189 (cu in) 578 1155 1733 2310 3465 2310 3465 4620 5775 6930 5775 6930 9240 11550

Gas Volume (Liters) 10.4 19.8 29.3 38.8 57.7 39.3 58.3 77.2 96.1 115.1 97.9 117 155 193

D-Port (Both Ends) A (mm) B (mm) 651 1032 1413 1794 2556 1194 1657 2118 2581 3044 1673 1897 2470 2997 BSPP/G (in) SAE Flange 2" Metric Code 61 Flange E (mm) F (mm) G (mm) Weight (Kg) 77 103 129 154 206 270 344 417 419 565 606 676 816 956

206.5 1.52

M16

150

24

279.9 2.29

2" Metric Code 61 Flange 3" Metric Code 61 Flange

M20

182

30

365.9 2.29

M20 (6X)

230

30

207 Bar Metric Auxiliary Gas Bottles


3 Mounting Holes E Thread G Depth

High Pressure MS 28889-2 Gas Valve

Threaded Port Configuration


Model No. Gas Bottle B7K0578D2K B7K1155D2K B7K1733D2K B7K2310D2K B7K3465D2K B9K2310D2K B9K3465D2K B9K4620D2K B9K5775D2K B9K6930D2K B12K5775D2K B12K6930D2K B12K9240D2K B12K11550D2K

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Gas Volume Nominal (gal) 2-1/2 Gal. 5 Gal. 7-1/2 Gal. 10 Gal. 15 Gal. 10 Gal. 15 Gal. 20 Gal. 25 Gal. 30 Gal. 25 Gal. 30 Gal. 40 Gal. 50 Gal. Actual (liters) 11.1 20.5 30.0 39.3 58.3 40.5 59.5 78.4 98.0 117.6 103 122 160 198 A (mm) B (mm) 692 1073 1454 1835 2597 1238 1700 2161 2623 3085 1715 1938 2512 3038 C (mm)

D-Hydraulic Port BSPP/G (in) SAE Flange 2" Metric Code 61 Flange E (mm) F (mm) G (mm) Weight (Kg) 73 99 125 150 202 248 322 396 469 543 565 635 775 915

206.5 1.52

41

M16

150

24

279.9 2.29

41

2" Metric Code 61 Flange 3" Metric Code 61 Flange

M20

182

30

365.9 2.29

41

M20 (6X)

230

30

31

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Non-ASME

3000 PSI Non-ASME Piston Accumulators for Oil and Water Service
ASME certification is a requirement of strength and material traceability (see page 4). Many states require ASME certification, but not all. It is the function of the system designer to specify whether ASME is or is not required. We now offer true non-ASME accumulators in 7 and 8 bore sizes which carry a full 4:1 design factor and utilize industry standard materials. When ASME certification is not required, specifying these accumulators can result in significant savings. Local rules and regulations should be followed. However, the accumulators listed on these two pages can be used with confidence when ASME certification is not required.

3 Mounting Holes E Thread G Depth

High Pressure MS28889-2 Gas Valve

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No.1 Oil Service A7N0578D3KPL A7N1155D3KPL A7N1733D3KPL A7N2310D3KPL A7N3465D3KPL A7N5775D3KPL A8N0578D3KPL A8N1155D3KPL A8N1733D3KPL A8N2310D3KPL A8N3465D3KPL A8N5775D3KPL

Fluid Volume (gal) 2 5 7 10 15 25 2 5 7 10 15 25 (cu in) 578 1155 1733 2310 3465 5775 578 1155 1733 2310 3465 5775

Gas Volume (cu in) 633 1210 1788 2365 3520 5830 655 1232 1810 2387 3542 5852

D-Hydraulic Port A (in) B (in) 27.25 42.25 57.25 72.25 102.25 162.25 22.94 34.81 46.68 58.50 82.28 129.68 C (in) SAE No. 32 1.63 Thread Size (in) 2 - 12 or 2 Code 61 Flange (PL)2 32 1.63 2-12 or 2 Code 61 Flange (PL)2 2 5/8-18 6.75 0.94 Tube Size 2 5/8 - 18 5.75 0.94 E (in) F (in) G (in) Weight (lbs) 170 226 283 340 454 682 216 268 321 374 479 690

8.13 0.06

9.06 0.06

Notes: 1) For Water Service add W after construction code, see How to Order information. 2) Most SAE #32 fittings are rated for 2000 PSI. If 2000 to 3000 PSI service is required, two options are available; order accumulator with optional standard 2" SAE Code 61 4-bolt flange port by specifying PL code when ordering or order the accumulator with a SAE #24 port or smaller, see Port Options for dimensions and How to Order. 3) See Port Options for complete listing of optional ports. 4) ASME Certified and CE marked accumulators and gas bottles are available. 5) When accumulators are to be used with gas bottles, order Accumulators for Use with Gas Bottles. 6) Poppet type (MS28889-2) gas valve standard.

32

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators Series 3000 Non-ASME

3000 PSI Non-ASME Accumulators for Use with Gas Bottles


Typical Both Ends
3 Mounting Holes E Thread G Depth D Gas Port

F Dia. Bolt Circle

Threaded Port Configuration

Flange Port Configuration

D Hydraulic Port

Accumulator Model No. A7N0578D3KPLPL A7N1155D3KPLPL A7N1733D3KPLPL A7N2310D3KPLPL A7N3465D3KPLPL A7N5775D3KPLPL A8N0578D3KPLPL A8N1155D3KPLPL A8N1733D3KPLPL A8N2310D3KPLPL A8N3465D3KPLPL A8N5775D3KPLPL

Fluid Volume (gal) 2 5 7 10 15 25 2 5 7 10 15 25 (cu in) 578 1155 1733 2310 3465 5775 578 1155 1733 2310 3465 5775

Gas Volume (cu in) 633 1210 1788 2365 3520 5830 650 1228 1806 2381 3537 5847

A (in)

B (in) 25.63 40.63 55.63 70.63 100.63 160.50 21.31 33.18 45.06 56.88 80.63 128.06

D Port (Both Ends)(in) 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread

E (in)

F (in)

G (lbs)

Weight 170 226 283 340 454 682 216 268 321 374 479 690

8.13 0.06

5/8 - 18

5.75

0.94

9.06 0.06

2" Code 61 Flange (PL)2 or #32 SAE Straight Thread

5/8 - 18

6.75

0.94

3000 PSI Non-ASME Auxiliary Gas Bottles


3 Mounting Holes E Thread G Depth High Pressure MS 28889-2 Gas Valve

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No. Gas Bottle B7N0578D3K(PL) B7N1155D3K(PL) B7N1733D3K(PL) B7N2310D3K(PL) B7N3465D3K(PL) B7N5775D3K(PL) B8N0578D3K(PL) B8N1155D3K(PL) B8N1733D3K(PL) B8N2310D3K(PL) B8N3465D3K(PL) B8N5775D3K(PL)

Gas Volume Nominal (gal) 2 5 7 10 15 25 2 5 7 10 15 25 Actual (cu in) 787 1309 1942 2464 3619 5929 772 1350 1928 2503 3659 5969 A (in) B (in) 27.25 42.25 57.25 72.25 102.25 162.13 22.94 34.81 46.68 58.50 82.25 129.68 C (in) D Port 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread E (in) F (in) G (in) Weight (lbs) 160 217 274 331 445 673 205 257 310 363 468 679

8.13 0.06

1.63

5/8 - 18

5.75

0.94

9.06 0.06

1.63

2" Code 61 Flange (PL)2 or #32 SAE Straight Thread

5/8 - 18

6.75

0.94

33

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators 2000 PSI Series 3000

2000 PSI Piston Accumulators for Oil and Water Service


The aluminum die casting industry has been the primary user of our 2000 PSI accumulators. We offer a 2000 PSI accumulator in 12 bore size and a variety of capacities for industries where lower pressure ratings can be used.

3 Mounting Holes E Thread G Depth

High Pressure MS28889-2 Gas Valve

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No.1 Oil Service A12K4620K1K A12K5775K1K A12K6930K1K A12K9240K1K A12K11550K1K

Fluid Volume (gal) 20 25 30 40 50 (cu in) 4620 5775 6930 9240 11550

Gas Volume (cu in) 4820 5975 7130 9440 11750

D-Hydraulic Port A (in) B (in) 55.75 66.19 76.62 97.50 118.37 C (in) SAE No. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 1048 1193 1338 1628 1918

14.02 0.09

1.62

3" SAE Flange Ports (Code 61) See Port Options for Dimensions

7/8-9 (6X)

9.00

1.50

Notes: 1) For Water Service add W after construction code, see How to Order information. 2) Most SAE #32 fittings are rated for 2000 PSI. If 2000 to 3000 PSI service is required, two options are available; order accumulator with optional standard 2" SAE Code 61 4-bolt flange port by specifying PL code when ordering or order the accumulator with a SAE #24 port or smaller, see Port Options for dimensions and How to Order. 3) See Port Options for complete listing of optional ports. 4) ASME Certified and CE marked accumulators and gas bottles are available. 5) When accumulators are to be used with gas bottles, order Accumulators for Use with Gas Bottles. 6) Poppet type (MS28889-2) gas valve standard.

34

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Models, Capacities and Dimensions

Piston Accumulators 2000 PSI Series 3000

2000 PSI Accumulators for Use with Gas Bottles


Typical Both Ends
3 Mounting Holes E Thread G Depth

F Dia. Bolt Circle

Threaded Port Configuration

Flange Port Configuration

D Hydraulic Port

Accumulator Model No. A12K4620K3KPNPN A12K5775K3KPNPN A12K6930K3KPNPN A12K9240K3KPNPN A12K11550K3KPNPN

Fluid Volume (gal) 20 25 30 40 50 (cu in) 4620 5775 6930 9240 11550

Gas Volume (cu in) 4820 5975 7130 9440 11750

A (in)

B (in) 54.13 64.56 75.00 95.88 116.75

D Port (Both Ends)(in) 3" SAE Flange Ports (Code 61) See Port Options for Dimensions

E (in)

F (in)

G (lbs)

Weight 1048 1193 1338 1628 1918

14.02 0.09

7/8 - 9 (6X)

9.00

1.50

2000 PSI Auxiliary Gas Bottles


3 Mounting Holes E Thread G Depth High Pressure MS 28889-2 Gas Valve

Threaded Port Configuration

F Dia. Bolt Circle

Flange Port Configuration

D Hydraulic Port

C B

Model No. Gas Bottle B12K4620K1K B12K5775K1K B12K6930K1K B12K9240K1K B12K11550K1K

Gas Volume Nominal (gal) 20 25 30 40 50 Actual (cu in) 4620 6288 7443 9783 12093 A (in) B (in) 55.75 66.19 76.62 97.50 118.37 C (in) D Port 3" SAE Flange Ports (Code 61) See Port Options for Dimensions E (in) F (in) G (in) Weight (lbs) 957 1167 1312 1606 1896

14.02 0.09

1.62

7/8 - 9 (6X)

9.00

1.50

35

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Options Water Service Option (W)

Piston Accumulators Series 3000

Piston accumulators are available for use with water as the fluid media. Modifications include electroless nickel plating all surfaces and metal parts. Consult factory for details.

Seals
Seal Code K E D H Polymer BunaNitrile Fluorocarbon Elastomer Ethylene Propylene Hydrogenated Nitrile Low Temp. Nitrile Operating Temperature Range -20F to 165F -29C to 74C -10F to 250F -23C to 121C -40F to 250F -40C to 121C -45F to 325F -43C to 162C -45F to 160F -43C to 71C

**Recommended

Maximum Temperature with Reduced Life 200F 93C 400F 204C 300F 149C 350F 177C 200F 93C

General Application and Compatibility* Parker's Standard Compound Compatible with most mineral oil-based fluids Compatible with most mineral oil-based fluids at higher temperatures and some exotic fluids Compatible with most phosphate ester fluids and some synthetic fluids Compatible with most oil-based and biodegradable fluids, maintains sealing effectiveness at a wide range of temperatures Compatible with most mineral oil-based fluids and maintains sealing effectiveness at low temperatures

*Note: Consult local distributor or factory for fluid compatibility information. ** The temperatures listed indicate the operating temperature range of the seals, not the accumulator. For the Minimum Design Metal Temperature (MDMT) of ASME certified accumulators, refer to page 28.

Gas Valve Option (M)


The military style (MS) gas valve is available on 2" thru 6" bores as an option (M). Specify when ordering.

1/220 UNF-2A

Safety Fuse Options (F)


Safety Fuses are used as a safety device on accumulators and gas bottles to prevent over-pressurization of gas due to external heat or hydraulic pressure (set at 140% of maximum system pressure to avoid rupture disk fatigue and premature failure). The rupture disks are calibrated to rupture at a predetermined pressure. Safety fuses are available on most sizes of piston and bladder accumulators and gas bottles. Safety fuses can be installed on all piston accumulators by using the Fuse Adapter as shown to the right. 4" bore units and above can be equipped with a fuse port machined in the gas cap by specifying the Safety Fuse Option (F) at the time of order in the model code, see How to Order. The safety fuse assembly and/or fuse adapter must be ordered separately.
Description Safety Fuse Assembly1 Replacement Rupture Disks Fuse Adapter Part Number 086471xxxx 756003xxxx 1468970002

Fuse
1.55

#8 SAE 3/4-16 UNF-2A

1.25

#8 SAE Straight Port Thd

0.70

0.95
#5 SAE Straight Port Thd

3.77

1.44

0.48

#5 SAE Straight Port Thd

1) Assembly includes housing and rupture disk, xxxx = pressure setting in 100 psi increments, i.e., for an assembly with a 2000 PSI setting, order P/N 0864712000.

Fuse Adapter

36

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Port Options Optional Ports

Piston Accumulators Series 3000

The following ports are available as options on all Series 3000 piston accumulators
SAE Straight Thd. Port Port Min. Size Code Bore #5 TA 2" #6 TB 2" #8 TC 2" #10 TI 2" #12 TD 2" #16 TE 3" #20 TF 3" #24 TG 4" Port Size 1/2" 3/4" 1" 1" 1" 2" 2" 3" Code 61 Flange Port Code Min. Inch Metric Bore PT MT 3" PU MU 3" PV MV 3" PW MW 3" PJ MJ 4" PL ML 6" PM MM 6" PN MN 7" NPT Port Port Size Code 3/8" UT 1/2" UU 3/4" UV 1" UW 1" UX 1" UY 2" UZ Min. Bore 2" 2" 2" 3" 3" 4" 4" BSPP Port Port Min. Size Code Bore 3/8" RA 2" 1/2" RB 2" 3/4" RC 2" 1" RD 3" 1" RE 3" 1" RF 4" 2" RG 4" ISO 6149-1 Port Port Min. Size Code Bore M14 YA 2" M18 YB 2" M22 YC 2" M27 YD 2" M33 YE 3" M42 YF 3"

Note: 1) 3000 PSI SAE Code 61 (ISO 6162) Flange dimensions are shown below. 2) BSPT and Metric ports available, consult factory.

SAE 4-Bolt Flange Port Dimensions


Standard Pressure 3000 PSI (207 Bar)

Flange Size in 1" 2" 2" 3"

SAE Code 61 Flange Dimensions (in.) A B C F G 1/2 - 13 1.406 2.750 1 1.062 1/2 - 13 1.688 3.062 2 1.062 1/2 - 13 2.000 3.500 2 1.188 5/8 -11 2.438 4.188 3 1.188

Note: Some flanges using this bolt pattern are not rated for 3000 PSI.
B

A (4 places) x G Min. Depth

Flange Size mm 38 51 64 76

Metric ISO6162 Flange Dimensions (mm) A B C F G M12 35.7 69.9 38 26.9 M12 42.9 77.8 51 26.9 M12 50.8 88.9 64 30.1 M16 61.9 106.4 76 30.1

Note: Some flanges using this bolt pattern are not rated for 3000 PSI.

Port Adapters
A wide variety of port adapters are offered for those that wish to convert Parkers standard SAE port offerings to NPTF or smaller SAE port sizes. For a complete listing, see Accumulator Accessories.

37

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Parts and Accessories Seal Kits


Seal Kits are available for all piston accumulator models. When ordering seal kits, please supply the complete model and serial numbers from the name plate and specify fluid type and operating temperature.

Piston Accumulators Series 3000

Parts List
1 2 3 4 5 5A 6 7 7A 8 8A 9 Body Hydraulic Cap Gas Cap Piston V-O-ring Piston Seal V-O-ring Backups PTFE Glide Rings O-ring O-ring Backup Gas Valve Gas Valve O-ring Gas Valve Guard

9A Screw

3000 PSI Seal Kit Numbers (Includes items 5, 5A, 6, 7, 7A, 8A)
Material Buna-Nitrile (Std.) Fluorocarbon EPR Hydrogenated Nitrile Low Temp Nitrile *CF = Consult Factory 2" RK0200K000 RK0200E000 RK0200D000 RK0200H000 RK0200Q000 3" RK0300K000 RK0300E000 RK0300D000 RK0300H000 RK0300Q000 4" RK0400K000 RK0400E000 RK0400D000 RK0400H000 RK0400Q000 Bore Size 6" RK0600K000 RK0600E000 RK0600D000 RK0600H000 RK0600Q000 7 RK0700K000 RK0700E000 RK0700D000 RK0700H000 RK0700Q000 9 RK0900K000 RK0900E000 RK0900D000 CF* RK0900Q000 12 RK1200K000 RK1200E000 CF* CF* CF*

Mounting, Charging & Gauging Accessories


Parker offers a wide variety of mounting, charging and gauging accessories. See Accumulator Accessories.

Special Options
If your application requires a piston accumulator, gas bottle, or special option that falls outside of Parkers broad offering, consult your local distributor, Parker representative, or the factory with your specific requirements. Parker has the manufacturing and engineering expertise to design and build piston accumulators to your exacting requirements, from simple modifications of standard units to complete designs. Some example of Parkers past special designs include: Special and Stainless Steel Materials Piston Position and Velocity Sensors and Switches Special Seals Non-Standard Capacities Tie Rod Construction Special Certifications Spring & Weight Loaded

Consult the experts at Parker with your next piston accumulator requirement!
38
Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Catalog HY10-1630/US

Ordering Information How to Order Piston Accumulators

Piston Accumulators Series 3000

Piston accumulators and gas bottles can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart. Nominal Bore Type of Size Construction Options Design Pressure Design Number Seal Compound Hyd. Port Modification Gas Port Modification

Series

Capacity

2310

Series A B Accumulator Gas Bottle 0005 0010 0029 0058 0029 0058 0090 0116 0183 0058 0116 0231 0347 0578 0231 0347 0578 0924 1155 1733 2310 0578 1155 1733 2310 3465 5775 0578 1155 1733 2310 3465 5755 2310 3465 4620 5775 6930 5775 6930 9240 11550

Bore Size/Capacity 2 5 cu. in. (0.08 liters) 10 cu. in. (0.16 liters) 29 cu. in. (0.48 liters) 58 cu. in. (0.95 liters) 29 cu. in. (0.48 liters) 58 cu. in. (0.95 liters) 90 cu. in. (1.47 liters) 116 cu. in. (1.90 liters) 183 cu. in. (3.00 liters) 58 cu. in. (0.95 liters) 116 cu. in. (1.90 liters) 1 gal. (3.79 liters) 1 gal. (5.69 liters) 2 gal. (9.47 liters) 1 gal. (3.79 liters) 1 gal. (5.69 liters) 2 gal. (9.47 liters) 4 gal. (15.1 liters) 5 gal. (18.9 liters) 7 gal. (28.4 liters) 10 gal. (37.9 liters) 2 gal. (9.47 liters) 5 gal. (18.9 liters) 7 gal. (28.4 liters) 10 gal. (37.9 liters) 15 gal. (56.8 liters) 25 gal. (94.6 liters) 2 gal. (9.47 liters) 5 gal. (18.9 liters) 7 gal. (28.4 liters) 10 gal. (37.9 liters) 15 gal. (56.8 liters) 25 gal. (94.6 liters) 10 gal. (37.9 liters) 15 gal. (56.8 liters) 20 gal. (75.7 liters) 25 gal. (94.6 liters) 30 gal. (113.6 liters) 25 gal. (94.6 liters) 30 gal. (114 liters) 40 gal. (151 liters) 50 gal. (189 liters)

Hydraulic and Gas Port Modifications Designated by 2 Digits 1st Digit Style Std. 2nd Digit Blank A B C D E F G H I Description Std. 2 2 2 2 3 3 4 7 2 Min. Bore 4 6 6 7 3 3 3 3 2 2 2 2 2 4 4 Metric/ISO 6149-1 A M14 x 1.5 B M18 x 1.5 C M22 x 1.5 D M27 x 2 E M33 x 2 F M42 x 2 G M48 x 2 Min. Bore Size

Nominal Bore Size 2 3 4 6 7 8 9 12 2 inches 3 inches 4 inches 6 inches 7 inches 8 inches 9 inches 12 inches

Blank

T SAE Straight Thread Ports

SAE #5 (1/2 - 20) SAE #6 (9/16 - 18) SAE #8 (3/4 - 16) SAE #12 (1 1/16 - 12) SAE #16 (1 5/16 - 12) SAE #20 (1 5/8 - 12) SAE #24 (1 7/8 - 12) SAE #32 (2 1/2 - 12) SAE #10 (7/8 - 14)

Type of Construction N Threaded both ends non-ASME matl standard on 2", 4", 6", 7" & 8" (3000 PSI fatigue design tested) Threaded both ends A.S.M.E. matl standard on 7 & up Same as K with A.S.M.E. approval stamp 7 & up. Available as special on smaller sizes Threaded both ends, CE marked (1 liter and above) or SEP marked (under 1 liter)

P Flange (Code 61) M Metric Flange per ISO 6162

U NPTF (Not Recommended)

R BSPP Parallel B BSPT Taper Port G Metric Y ISO 6149-1

J 1 1/2 L 2 M 2 1/2 N 3 T 1/2 U 3/4 V 1 W 1 1/4 T 3/8 U 1/2 V 3/4 W 1 X 1 1/4 Y 1 1/2 Z 2 BSPP/BSPT A 3/8 - 19 B 1/2 - 14 C 3/4 - 14 D 1 - 11 E 1 1/4 - 11 F 1 1/2 - 11 G 2 - 11

Options Blank W F G M L P R Standard Gas Cap Water Service SAE Fuse Port * SAE Fuse Port *, Water Service MS28889-2 Gas Valve MS28889-2 Gas Valve, Water Service Fuse* and MS28889-2 Fuse* and MS28889-2, Water Service

12

Example of Optional Port Accumulator


A 4 N 0231 D 3
Non-std. Port

Consult factory for other available sizes.

SAE #8 Hyd. Port

NPT 3/4 Gas Port

Design Pressure D K X L H 3000 PSI (All Bore Sizes) 2000 PSI (12" Bore only) Other For CE Marked Only 250 Bar (All Bore Sizes) 350 Bar (See page 63) Standard Ports Available (See Port Modifications Table if Using Other Than Standard Ports Shown Below) Bore Size 2 3 4 6 7 8 9 12 Standard Port Sizes SAE #12 SAE #12 SAE #20 SAE #24 SAE #32 SAE #32 SAE #32 3 SAE Flange Code 61 Metric Port Sizes 3/4 3/4 1 1 ISO 6162 ISO 6162 ISO 6162 ISO 6162 Seal Compound (See Catalog for Temperature Settings) K E D H Q S Buna-Nitrile (Std) Fluoroelastomer EPR Hydrogenated Nitrile Low Temp. Special (to be specified)

* Safety fuse assembly not included. Order fuse assembly separately.

Design Number 1 2 3 *** Standard Metric Mounting Holes & Hyd. Port (BSPP Standard) Specify Optional Ports Optional Port (Hyd. or Gas, See Port Table) Special Design

39

Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA

Você também pode gostar