Você está na página 1de 6

OCMR

Optical Communications Mainframe with Redundant power supplies

About the Product


The OCMR with redundant power supply capability is the second generation Optical Communications Mainframe Chassis which forms the backbone of the Light Link Series 3 product range. The OCMR chassis is fully backward compatible with PBNs complete range of optical, RF and data modules to suit CATV, Ethernet, FTTC, FTTH, HFC and telecommunication applications. The new design employs the same form factor as its predecessor, the OCMC, still 5 RU high, 19 rack mountable, but now with 10 slots for high-density applications and full power redundancy. Comprehensive control and monitoring of the OCM is included in the chassis itself, with a 4-line LCD and keypad to navigate through any of the modules various monitoring and control features. As a crucial element in any small or large city optical network, the OCMR is designed with fully modular and hot-swappable active parts that allow for continuous system operation, providing uninterrupted services to the end subscriber. The OCMR can be optioned with an integrated SNMP agent and Ethernet port. This makes it possible to monitor and control an OCMR chassis through an IP network with PBNs NMS3-NetCraft software or an SNMP manager.

Downloaded 26.04.2011 by Jbartha@fibersecurity.com.ar. Reproduction without consent is prohibited. Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4f - Released 04 Aug 10

1/6

OCMR
Optical Communications Mainframe with Redundant power supplies

Features
5 RU high, 19" wide, 10-slot chassis for PBN designed plug-in modules. Can be equipped with dual, hot-swappable power supplies for redundant power applications. Large LCD panel for easy setup of modules and system monitoring. IEC297 compatible 19" rack. Space below modules for optical fibre patch-cords and RF cable access. Mountable at RU intervals allowing maximum use of rack space in communications cabinets. Horizontal, fan-forced airflow permits the mounting of multiple OCMR without the need for rack space clearance between chassis. Local monitoring of system and modules via USB port. Remote monitoring via optional integrated SNMP agent and web server (HTTP) through 10Base-T Ethernet port for system wide, NMS3 network management. Hot-swappable front-panel display and micro-controller assembly.

Remote monitoring and control features with the SNMP option


During normal operation the OCM user interface runs in status-monitoring mode where it continuously checks the entire OCMR chassis for urgent alarm conditions. If any of the plug-in modules report an urgent failure, the LCD display will flash and the alarm condition is made available via the software for remote monitoring computers. The OCMR also monitors various other module parameters for non-urgent alarm conditions. The OCMR employs an optional NMS3 network element manager, which acts as a Simple Network Management Protocol (SNMP) agent and a web server for monitoring via a web browser. The SNMP agent and web server are available through a rear-mounted, RJ45 (10Base-T) Ethernet port. The SNMP option is supplied with a PBN Management Information Base (MIB), as well as PBNs NMS3NetCraft software for Windows XP workstations. The PBN MIB is complementary to the Society of Cable Telecommunications Engineers (SCTE) published HMS standard MIB's. The OCMR is fully compatible with PBN NMS3-Enterprise II and NMS3-EPSM, with BarcoNet ROSA, with HP Open View, with CA Unicenter, with Castle Rock, with NuDesign and with many other standards-based SNMP monitoring packages. Please refer to our datasheets for NMS3-NetCraft, Enterprise II and NMS3-EPSM for more details on the comprehensive network management features, the operational support systems, the provisioning systems and the billing systems.

Downloaded 26.04.2011 by Jbartha@fibersecurity.com.ar. Reproduction without consent is prohibited. Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4f - Released 04 Aug 10

2/6

OCMR
Optical Communications Mainframe with Redundant power supplies

NMS3 Network Management System Components


NMS3 - Netcraft NMS3 - EPSM NMS3 - Enterprise II

SNMP

Light Link Series 2

Light Link Series 3

Specifications
OCMR Chasis Module slots Alarms Monitoring and control 10 x OCM plug-and-play module capable. Directly to front-panel LCD, remotely to, NO and NC alarm relay contact. Integrated 4-line LCD display and keypad, USB port for local monitoring via laptop, SNMP network option with Ethernet port for remote monitoring and control via NMS3-NetCraft and NMS3-Enterprise-II systems. 10Base-T, RJ45 socket. (Only with SNMP option) Automatically via DHCP, or use static address through frontpanel keypad and LCD. (Only with SNMP option) Configuration software on CD. (Supplied as a free inclusion to
OCMR with SNMP option)

Ethernet port IP address setting NMS3-NetCraft-CD

Downloaded 26.04.2011 by Jbartha@fibersecurity.com.ar. Reproduction without consent is prohibited. Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4f - Released 04 Aug 10

3/6

OCMR
Optical Communications Mainframe with Redundant power supplies

OCMPS Electrical Performance Power supply modules Up to 2 hot-swappable modules in the top tray of OCMR. One power supply can power a fully-loaded chassis. 2 power supplies provide redundancy in case of single power supply failure. 90 Vac to 264 Vac, 50/60 Hz 90 Vac to 264 Vac, 50/60 Hz -45 Vdc to -62 Vdc 2.5 A max. 10 A max. In-built, thermistor-controlled cooling fans. Two fans per power supply module. 26.0 V, 4.0 A max., 14.5 V, 3.0 A max., -14.5 V, 1.0 A max. 7.5 V, 7.0 A max. 26.5 V, 9.5 A max., 14.5 V, 9.0 A max., -14.5 V, 1.0 A max. 7.5 V, 10.0 A max. 0 C to 45 C Via cooling fans in OCMPS** and OCMFAN modules. 870 BTU/h for a fully-loaded chassis. 225 x 485 x 440 mm 50 x 210 x 350 mm 400 x 600 x 600 mm 70 x 280 x 570 mm 6.5 kg 2.2 kg 2.0 kg 2.0 kg 1.0 kg 13 kg 3.2 kg 2.6 kg 2.6 kg 1.6 kg

Power input OCMPS-230 OCMPS-HP-230 OCMPS-48 Inrush current OCMPS-230 OCMPS-48 Cooling General Power rails OCMPS OCMPS-HP Operating temperature Cooling Maximum heat generation Dimensions (HxWxD) OCMR OCMPS-[*] / OCMFAN Ship size (HxWxD) OCMR OCMPS-[*] / OCMFAN Weight OCMR OCMPS-230 OCMPS-48 OCMPS-HP-230 OCMFAN Ship weight OCMR OCMPS-230 OCMPS-48 OCMPS-HP-230 OCMFAN

Downloaded 26.04.2011 by Jbartha@fibersecurity.com.ar. Reproduction without consent is prohibited. Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4f - Released 04 Aug 10

4/6

OCMR
Optical Communications Mainframe with Redundant power supplies

Order Details
OCMR-0 OCMR-SNMP OCMR-SNMP-2B Chassis, empty. Chassis with SNMP module. Chassis with SNMP module, with 2 x 48 V battery power supply modules.

OCMR-SNMP-ARC Chassis with SNMP module, with Alarm Relay Connection (ARC) providing relay output triggered by urgent alarms. No power supplies. OCMR-SNMP-AU OCMR-SNMP-CN OCMR-SNMP-EU OCMR-SNMP-HP OCMR-SNMP-UK OCMR-SNMP-US Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for Australia GPO. Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for mainland China GPO. Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for continental Europe GPO. Chassis with SNMP module, with 2 x 470 W mains power supply modules, with 2 x mains cables for each AU/CN/EU/UK/US. Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for United Kingdom GPO. Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for USA GPO.

Power and cooling modules for OCMR chassis


OCMPS-230 OCMPS-48 OCMPS-HP-230 OCMFAN Power supply module with fans for 90~264 Vac 50/60 Hz. 300 W Power supply module with fans for -48 Vdc. 300 W Power supply module with fans for 90~264 Vac 50/60 Hz. 472 W
Required for QOLTM deployments

Fan module for OCMR **

** Note: If more than 5 modules are loaded in a chassis, for the purpose of adequate cooling, either a second OCMPS-[X] power supply module or an OCMFAN module must be installed. The fan module is powered from the chassis rails and does not need a power cord.

Downloaded 26.04.2011 by Jbartha@fibersecurity.com.ar. Reproduction without consent is prohibited. Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4f - Released 04 Aug 10

5/6

OCMR
Optical Communications Mainframe with Redundant power supplies

Light Link Series 3 modules to suit OCMR chassis


AGC3 EDFAM FPRM LTM13 LTM15 LTM802 OLTM OPSAB OPSC OSLAM OSMS OWDM QOLTM RFABM RPQRM SCMM RF Laser Drive Module with automatic gain control
45~1000 MHz forward path or 5~200 MHz return path

Erbium Doped Fibre Amplifier Module


From 20 mW to 250 mW with up to 8 outputs

Forward Path Receiver Module


45~1000 MHz forward path, with automatic gain control

Laser Transmitter Module 1310 nm


45~1000 MHz forward path or 5~200 MHz return path, 1 mW to 32 mW.

Laser Transmitter Module 1550 nm for ITU DWDM grid


45~1000 MHz forward path or 5~200 MHz return path, 6, 8 or 10 mW

Line Terminal Module for Fast Ethernet or Gigabit Ethernet


Up to 110 km bi-directional over one fibre core

Optical Line Terminal Module


For IEEE802.3ah compliant Gigabit Ethernet PONs with up to 32/64 nodes per fibre

Optical Protection Switch AB Module


With optional internal optical input sensing

Optical Switching Coupler Module


With optional internal optical input sensing

Optical Subscriber Line Access Multiplexer


With 8 line ports for CATV and Fast Ethernet over one fibre core

Optical Splitter Module


Up to 8 ports

Optical Wavelength Division Multiplexer


For CWDM or DWDM up to 8 ports

Quad Optical Line Terminal Module


For IEEE802.3ah compliant Gigabit Ethernet PONs with up to 128/256 nodes per module

RF Protection Switch Module


5~1000 MHz with optional pilot detection

Return Path Quad Receiver Module


5~200 MHz return path with 4.5 MHz pilot for AGC and FSK monitoring

System Control and Monitoring Module


For OLTM and QOLTM modules. Requires one SCMM per OCMR.

For more information


Contact PBN for further information. 8-10 Keith Campbell Court Scoresby, Victoria 3179, Australia Phone: +61-3-9780-5100 Fax: +61-3-9763-5522 Email: info@pbn.com.au www.pbnglobal.com PBN is an ISO 9001:2008 Quality certified and C-Tick compliant company.

Downloaded 26.04.2011 by Jbartha@fibersecurity.com.ar. Reproduction without consent is prohibited. Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4f - Released 04 Aug 10

6/6

Você também pode gostar