Escolar Documentos
Profissional Documentos
Cultura Documentos
CH, CHN
Horizontal multistage end-suction pumps
Contents
General description
Product description Applications Pumped liquids Operating conditions Pump Motor Performance range 3 3 3 3 3 4 4
Identification
Type key CH and CHN 5
Construction
CH, CHN 2-50 CH, CHN 4-60 CH 8-50 CH 12-50 Material specification 6 7 8 9 10
Curve conditions
Curve conditions How to read the curve charts 12 13
Performance curves
CH 2, CHN 2 CH 4, CHN 4 CH 8 CH 12 14 15 16 17
Electrical data
CH, CHN 2 CH, CHN 4 CH 8 CH 12 18 18 18 19
General description
Product description
The Grundfos CH and CHN pumps are non-self-priming, horizontal, multistage, centrifugal pumps. Pump and motor are integrated in a compact and userfriendly design making the pumps suitable for installation in compact systems. The pump is fitted with a maintenance-free, mechanical shaft seal and through-going pump-motor shaft. CH: Chambers as well as all moving parts in contact with the pumped liquid are made of stainless steel. Discharge chamber, suction chamber and base plate are made of cast iron/iron and painted non-gloss black. CHN: Discharge chamber, suction chamber, base plate as well as all parts in contact with the pumped liquid are made of stainless steel. The motor is painted non-gloss black. The pump is UL Listed to US and Canadian safety standards.
CH, CHN
Operating conditions
Liquid temperature range: Max. ambient temperature: 32F to +176F +131F.
The maximum operating pressure depends on the temperature of the pumped liquid, see table:
Max. operating pressure CH 2, CHN 2 CH 4, CHN 4 CH 8 CH 12 145 psi (10 bar) 32F to +104F 32F to +131F 87 psi (6 bar) +105F to +176F +132F to +176F
According to the NPSH curve plus a safety margin of 2 feet. Limited by the max. operating pressure.
Pump
The CH, CHN pumps are non-self-priming, horizontal, multistage, centrifugal pumps with mechanical shaft seal and through-going pump-motor shaft. The pumps have axial suction port and radial discharge port and are mounted on a base plate. All movable parts in contact with the pumped liquid are made of stainless steel. EPDM or FKM O-rings are available as standard. For pipe connections, see the table:
Connections Axial suction port Radial discharge port Drain hole, priming hole CH 2, CHN 2 NPT 1 NPT 1 Rp 3/8 CH 4, CHN 4 NPT 1 NPT 1 Rp 3/8 CH 8 NPT 1 NPT 1 Rp CH 12 NPT 1 NPT 1 Rp
Applications
The CH and CHN pumps are designed for small domestic and industrial systems. Applications include Liquid transfer and circulation of liquids within light industry and farming Pressure boosting in single-pump and multi-pump booster systems Domestic water supply Cooling systems Air-conditioning systems.
Pumped liquids
CH Thin, clean, non-aggressive and non-explosive liquids without solid particles or fibers. CHN Thin, clean, slightly aggressive and non-explosive liquids without solid particles or fibers.
Fig. 1 CH pump
General description
Motor
The pump is fitted with a totally enclosed, fan-cooled, squirrel-cage Grundfos motor. Rated speed: Enclosure class: Insulation class: Standard voltages: 3500 min-1 IP 54 F 1 x 115-230 V, 3 x 208-230/460 3 x 575 V
CH, CHN
Single-phase motors have built-in thermal overload protection. Three-phase motors must be connected to a motor starter according to local regulations.
Performance range
CH, CHN, 60 Hz
H [m] H [ft]
280 80 260 240 70 220 60 200 180 50 160 140 40 120 30 100 80 20 CH 2 60 40 20
TM03 3377 0306.
CH, CHN
60 Hz
ISO 9906 Annex A
CH 4 CHN 4
CH 8
CH 12
CHN 2
10
0 0 0 5 1 10 2 3 15 4 20 5 25 6 30 7 35 8 40 9 45 10 50 11 12 55 13 60 14 65 15
Q [US GPM]
16
Q [m/h]
Identification
Type key CH and CHN
Example Type range CH(N) 4 -30 A -B -A -AQQE
CH, CHN
Code for pipe connection Code for materials, excluding plastic and rubber parts Code for shaft seal*
Construction
CH, CHN 2-50
Sectional drawings
CH, CHN
25
37
62
65 4
45
66
67
150a
28
56
28g
79
Components
Pos. 2 4 6 25 28 28g 37 45 49 Component Discharge chamber Chamber Suction chamber Plug Screw Hexagon head screw Gasket Neck ring Impeller Pos. 56 62 64 65 66 67 79 105 150a Component Base plate Stop ring Spacing pipe Retainer for neck ring Clamp Lock nut Diverting disc Shaft seal Stator housing Pos. 151 153,154 155 156 158 159 164 164a 172 Component Fan cover Ball bearing Bearing cover plate Fan Corrugated spring O-ring Terminal box cover Terminal box Shaft
Construction
CH, CHN 4-60
Sectional drawing
CH, CHN
62
37
4a 47a
66
67
150a
28
56
28g
Components
Pos. 2 4 4a 6 25 28 28g 37 47a 49 Component Discharge chamber Chamber Chamber with bearing Suction chamber Plug Screw Hexagon head screw Gasket Bearing Impeller Pos. 56 62 64 64a 66 67 79 105 150a 151 Component Base plate Stop ring Spacing pipe Spacing pipe Clamp Lock nut Diverting disc Shaft seal Stator housing Fan cover Pos. 153,154 155 156 158 159 164 164a 172 Component Ball bearing Bearing cover plate Fan Corrugated spring O-ring Terminal box cover Terminal box Shaft
Construction
CH 8-50
Sectional drawing
158 159 150a 154 172 164 164a 41 156 151 25 2 1a 105 37a 49 49a 37
CH, CHN
65 45 6
25
153
155 41a
79
28h
28g
56 45 65 4
26
64
66
67
Components
Pos. 1a 4 6 25 26 28 28g 28h 37 37a 41 Component Pump housing Chamber Suction chamber Plug Staybolt Screw Hexagon head screw Serrated lock washer Gasket Gasket Bearing plate Pos. 45 49 49a 56 64 65 66 67 79 105 150a Component Neck ring Impeller Impeller Base plate Spacing pipe Retainer for neck ring Clamp Lock nut Diverting disc Shaft seal Stator housing Pos. 151 153,154 155 156 158 159 164 164a 172 Component Fan cover Ball bearing Bearing cover plate Fan Corrugated spring O-ring Terminal box cover Terminal box Shaft
Construction
CH 12-50
Sectional drawing
CH, CHN
154
159
172
164
153
2 41 1a
105
37a
49
49a
37
151
25
65 45 6
25
181
150a
155
79
41a
28h 28g
56
45 65 4
26
64
66
67
Components
Pos. 1a 4 6 25 26 28 28g 28h 37 37a 41 Component Pump housing Chamber Suction chamber Plug Staybolt Screw Hexagon head screw Serrated lock washer Gasket Gasket Bearing plate Pos. 45 49 49a 56 64 65 66 67 79 105 150a Component Neck ring Impeller Impeller Base plate Spacing pipe Retainer for neck ring Clamp Lock nut Diverting disc Shaft seal Stator housing Pos. 151 153,154 155 156 156a 157a 158 159 164 172 181 Component Fan cover Ball bearing Bearing cover plate Fan Non-drive end shield Lip seal Corrugated spring O-ring Terminal box cover Shaft Staybolt
Construction
Material specification
Pos. 105 62 150 150a 151 Description Shaft seal Stop ring Stator housing complete with terminal box Stator housing Fan cover Stainless steel Silumin/composite (ML 71 and ML 80) Silumin (ML 90) Silumin/composite (ML 71 and ML 80) Silumin (ML 90) Steel (ML 71 and ML 80) Composite PBT/PC (ML 90) Stainless steel Composite PA 66 30% GF Silumin 1.0330.3 1.0330.3 1.4401 AISI 316 1.4401 Material CH DIN W.-Nr. ISO/AISI/ASTM DIN W.-Nr. CHN
CH, CHN
ISO/AISI/ASTM
153, 154 Ball bearing 155 156 156a 157a 158 159 159a 164 164a 172 172a 181 1a 2 4 4a 6 25 26 28 28g 28h 37, 37a 41 45 47a Bearing cover plate Fan Non-drive end shield (ML 90) Lip seal (ML 90) Corrugated spring O-ring Gasket Terminal box cover Terminal box Shaft: pump Shaft: motor Shaft, complete Staybolt (only ML 90) Pump housing Discharge chamber Chamber Chamber with bearing (CH 4) Suction chamber, compl. Plug Staybolt Screw Hexagon head screw Serrated lock washer Gasket Bearing plate Neck ring Bearing (shaft) (CH 4-60) Impeller CH 8 and 12: 130 CH, CHN 4: 95 CH, CHN 2: 90 Impeller CH 8 and 12: 98 Base plate Spacing pipe Retainer for neck ring Clamp Lock nut Diverting disc Synthetic-fibre-reinforced rubber (NBR) Cast iron/stainless steel PTFE Chromium-nickel-molybdenumcemented tungsten carbide Stainless steel Stainless steel Iron/stainless steel Stainless steel Stainless steel Stainless steel Stainless steel NR rubber 1.4301 1.4301 1.0330.3 1.4401 1.4301 1.4401 1.4301 AISI 316 AISI 304 AISI 316 AISI 304 AISI 304 AISI 304 1.4301 1.4301 1.4301 1.4401 1.4301 1.4401 1.4301 AISI 304 AISI 304 AISI 304 AISI 316 AISI 304 AISI 316 AISI 304 0.6020 ASTM 30 B 1.4308 CF 81) Stainless steel Steel Stainless steel/steel Steel Cast iron/stainless steel Cast iron/stainless steel Stainless steel Stainless steel + aluminium oxide Al2O3 (ceramic) Cast iron/stainless steel Free-cutting steel/stainless steel Galvanized steel 0.6020 0.6020 1.4301 1.4301 0.6020 1.0718 ASTM 30 B ASTM 30 B AISI 304 AISI 304 ASTM 30 B 1.4308 1.4308 1.4301 1.4301 1.4308 1.4301 CF 81) CF 8 1) AISI 304 AISI 304 CF 8 1) AISI 304 1.4057 1.0531 1.4057/ 1.0531 AISI 431 AISI 431 1.4057 1.0531 1.4057 1.0531 AISI 431 AISI 431 NBR rubber 1.4301 AISI 304 1.4301 AISI 304
Pump parts
10
11
Curve conditions
Curve conditions
The guidelines below apply to the curves on the following pages: Tolerances according to ISO 9906, Annex A. The bold curves state the recommended performance range. The thin curves are only intended as a guide. The curves must not be used as guarantee curves. All curves are based on measurements at: 1 x 220 V, 60 Hz 3 x 380 V, 60 Hz. When the motor is running at the lowest or highest rated voltage, the pump performance will usually vary by 1.5 - 3 feet at a given duty point. Specific minimum performance requirements necessitate individual measurements. The measurements have been made with airless water at a temperature of 70F (~20C). The curves apply to a kinematic viscosity of = 1 mm/s (1 cSt)
CH, CHN
12
Curve conditions
How to read the curve charts
Curves QH: P2: Eff: Pump performance at actual speed. Pump input, i.e. pump without motor.
CH, CHN
Total efficiency, i.e. pump with motor, is shown in the curve charts as Eff. NPSH: Average values for all variants shown in chart 1. When sizing, make a safety allowance of at least 2 feet.
H [m]
H [ft]
280 CH(N) 2-60 260 240
CH 2, CHN 2
60 Hz
ISO 9906 Annex A
80
Pump type
70 220 60 200 180 50 160 140 40 120 30 100 80 20 60 40 10 20 0 0 0 2 4 6 8 10 12 14 16 CH(N) 2-30 CH(N) 2-40 CH(N) 2-50
QH curve for the individual pump. The bold curve indicates the recommended performance range.
Q [US GPM]
4.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Q [m/h]
The power curve indicates pump input power [P2]
P2 [kW]
1.0
P2 [hp]
1.5 1.0 -60 -50 -40 -30
Q [US GPM]
Eff
H [m]
12 8 4 0
H [ft]
40 30 20 10 0 0 2 4 6 8 10 12 14 16
NPSH
10 0
Q [US GPM]
Eff The NPSH curve is [%] an average curve for all variants shown. 40 When sizing the 30 pumps, add a safety margin of at least 2 20 feet.
13
Performance curves
CH 2, CHN 2
H [m] H [ft]
280 80 CH(N) 2-60 260 240 70 220 60 200 180 50 160 140 40 120 30 100 80 20 60 40 10 20 0 0 0 2 4 6 8 10 12 14 16 CH(N) 2-30 CH(N) 2-40 CH(N) 2-50
CH, CHN
CH 2, CHN 2
60 Hz
ISO 9906 Annex A
Q [US GPM]
4.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Q [m/h]
P2 [kW]
1.0
P2 [hp]
1.5 1.0 -60 -50 -40 -30
Q [US GPM]
Eff
H [m]
12 8 4 0
H [ft]
40 30 20 10 0 0 2 4 6 8 10 12 14 16
Eff [%]
40 30
NPSH
20 10 0
TM03 3103 0306
Q [US GPM]
14
Performance curves
CH 4, CHN 4
H [m]
70 220 200 180 CH(N) 4-40 50 160 140 40 120 100 CH(N) 4-20 80 20 60 40 10 20 0 0 0 5 10 15 20 25 30 35 CH(N) 4-30
CH, CHN
H [ft]
240 CH(N) 4-50
CH 4, CHN 4
60 Hz
ISO 9906 Annex A
60
30
Q [US GPM]
9
Q [m/h]
-50 -40 -30 -20
P2 [kW]
1.0 0.5 0.0
P2 [hp]
2.0 1.5 1.0 0.5 0.0 0 5 10 15 20 25 30 35
Q [US GPM]
Eff
H [m]
6 4 2 0
H [ft]
20 15 10 5 0 0 5 10 15 20 25 30 35 NPSH
Eff [%]
40 30 20 10 0
TM03 3103 0306
Q [US GPM]
15
Performance curves
CH 8
H [m] H [ft]
180 50 CH 8-40
CH, CHN
CH 8
60 Hz
ISO 9906 Annex A
160
140 40 120
CH 8-30
30
100
CH 8-25 CH 8-20
80 20 60
40 10 20
0 0 5 10 15 20 25 30 35 40 45 50
Q [US GPM]
12
10
Q [m/h]
P2 [kW]
1.0 0.5 0.0
P2 [hp]
2.0 1.5 1.0 0.5 0.0 0 5 10 15 20 25 30 35 40 45 50
Q [US GPM]
H [m]
3
H [ft]
12 8 Eff NPSH
Eff [%]
60 40
TM03 3104 0506
2 1 0 4 0 0 5 10 15 20 25 30 35 40 45 50 20 0
Q [US GPM]
16
Performance curves
CH 12
p [kPa]
450
CH, CHN
H [ft]
160 150 140 CH 12-30
CH 12
60 Hz
ISO 9906 Annex A
400 130 350 120 110 300 100 90 250 80 200 70 60 CH 12-10 150 50 40 100 30 20 10 0 0 0 5 10 15 20 25 30 35 40 45 50 55 60 CH 12-20
50
Q [US GPM]
15
10
11
12
13
14
Q [m/h]
P2 [kW]
2
P2 [hp]
3 2 -30 -20 -10
1 1 0 0
H [m]
8
H [ft]
24 16
10
15
20
25
30
35
40
45
50
55
60
Q [US GPM]
Eff [%]
60 40
TM03 3105 0306
Eff NPSH
4 8 0 0 0 5 10 15 20 25 30 35 40 45 50 55 60 20 0
Q [US GPM]
17
Electrical data
CH, CHN I1/1 indicates maximum rated current within the voltage range. Ist indicates maximum locked rotor current within the voltage range.
CH, CHN
CH, CHN 2
Voltage [V] Frequency [Hz] Pump type CH, CHN 2-30 CH, CHN 2-40 CH, CHN 2-50 CH, CHN 2-60 CH, CHN 2-30 CH, CHN 2-40 CH, CHN 2-50 CH, CHN 2-60 CH, CHN 2-30 CH, CHN 2-40 CH, CHN 2-50 CH, CHN 2-60 Motor type ML 71 ML 71 ML 71 ML 80 ML 71 ML 80 ML 80 ML 80 ML 71 ML 71 ML 71 ML 80 SF 1.70 1.70 1.70 1.60 1.60 1.50 1.50 1.50 1.70 1.70 1.70 1.60 I1/1 [A] 2.90/1.45 4.0/2.10 4.0/2.10 5.20/2.60 9.00/4.50 11.5/5.70 11.5/5.70 15.0/7.50 1.16 1.68 1.68 2.08 Ist [A] 15.7 20.7 20.7 32.0 24.9 34.0 34.0 48.0 15.7 8.0 8.0 11.2 Motor P2 [HP] 0.50 0.75 0.75 1.00 0.50 0.75 0.75 1.00 0.50 0.75 0.75 1.00 40/400 40/400 40/400 50/400 C [F/V]
3 x 208-230/440-480
60
1 x 115/230
60
3 x 575 (Canada)
60
CH, CHN 4
Voltage [V] Frequency [Hz] Pump type CH, CHN 4-20 CH, CHN 4-30 CH, CHN 4-40 CH, CHN 4-50 CH, CHN 4-20 CH, CHN 4-30 CH, CHN 4-40 CH, CHN 4-50 CH, CHN 4-20 CH, CHN 4-30 CH, CHN 4-40 CH, CHN 4-50 Motor type ML 71 ML 71 ML 80 ML 80 ML 71 ML 71 ML 80 ML 90 ML 71 ML 71 ML 80 ML 80 SF 1.70 1.70 1.60 1.47 1.60 1.50 1.50 1.40 1.70 1.70 1.60 1.47 I1/1 [A] 2.90/1.45 4.0/2.10 5.20/2.60 6.90/3.50 9.00/4.50 11.5/5.70 15.0/7.50 21.5/10.7 1.16 1.68 2.08 2.80 Ist [A] 15.7 20.7 33.9 42.0 24.9 34.0 33.9 33.9 5.1 8.0 11.2 15.3 Motor P2 [HP] 0.50 0.75 1.00 1.50 0.50 0.75 1.00 1.50 0.50 0.75 1.00 1.50 40/400 40/400 50/400 60/400 C [F/V]
3 x 208-230/440-480
60
1 x 115/230
60
3 x 575 (Canada)
60
CH 8
Voltage [V] Frequency [Hz] Pump type CH 8-20 CH 8-25 CH 8-30 CH 8-40 CH 8-20 CH 8-25 CH 8-30 CH 8-40 CH 8-20 CH 8-25 CH 8-30 CH 8-40 Motor type ML 71 ML 80 ML 80 ML 80 ML 80 ML 80 ML 90 ML 90 ML 71 ML 80 ML 80 ML 80 SF 1.70 1.60 1.47 1.47 1.50 1.50 1.40 1.40 1.70 1.60 1.47 1.47 I1/1 [A] 4.0/2.10 5.20/2.60 6.90/3.50 6.90/3.50 11.5/5.70 15.0/7.50 21.5/10.7 21.4/10.6 1.68 2.08 2.80 2.80 Ist [A] 15.6 20.4 32.0 32.0 34.0 48.0 83.0 32.0 8.0 11.2 15.3 15.3 Motor P2 [HP] 0.75 1.00 1.50 1.50 0.75 1.00 1.50 1.50 0.50 1.00 1.50 1.50 40/400 50/400 60/400 60/400 C [F/V]
3 x 208-230/440-480
60
1 x 115/230
60
3 x 575 (Canada)
60
18
Electrical data
CH 12
Voltage [V] 3 x 208-230/440-480 1 x 115/230 3 x 575 (Canada) Frequency [Hz] 60 60 60 Pump type CH 12-10 CH 12-20 CH 12-30 CH 12-10 CH 12-20 CH 12-10 CH 12-20 CH 12-30 Motor type ML 71 ML 80 ML 90 ML 71 ML 90 ML 71 ML 80 ML 90 SF 1.70 1.47 1.50 1.60 1.40 1.70 1.47 1.50 I1/1 [A] 2.90/1.45 6.90/3.50 9.10/4.75 9.00/4.50 21.5/10.7 1.16 2.80 3.80 Ist [A] 15.7 32.0 46.0 24.9 83.0 5.1 15.3 28.0 Motor P2 [HP] 0.50 1.50 2.00 0.50 1.50 0.50 1.50 2.00
CH, CHN
C [F/V]
40/400 60/400
19
CH, CHN
NPT 1 Rp 1
B1 B2
0.33 8.5
Rp 3/8
TM00 1491 4900
L2 L3
L1
CH, CHN 2
Voltage [V] Frequency [Hz] Pump type CH, CHN 2-30 CH, CHN 2-40 CH, CHN 2-50 CH, CHN 2-60 CH, CHN 2-30 CH, CHN 2-40 CH, CHN 2-50 CH, CHN 2-60 CH, CHN 2-30 CH, CHN 2-40 CH, CHN 2-50 CH, CHN 2-60 Motor type ML 71 ML 71 ML 71 ML 80 ML 71 ML 80 ML 80 ML 90 ML 71 ML 71 ML 71 ML 80 L1 [Inch] 12.68 15.04 15.75 16.42 12.68 15.00 15.71 16.38 12.68 15.04 15.75 16.42 L2 [Inch] 3.62 4.33 5.04 5.75 3.62 4.33 5.04 5.75 3.62 4.33 5.04 5.75 L3 [Inch] 3.19 3.90 4.61 5.32 3.19 3.90 4.61 5.32 3.19 3.90 4.61 5.32 L4 [Inch] 4.61 5.32 6.06 6.77 4.61 5.32 6.06 6.77 4.61 5.32 6.06 6.77 B1 [Inch] 5.75 5.75 5.75 5.57 5.75 5.57 5.57 5.57 5.75 5.75 5.75 5.57 B2 [Inch] 4.33 4.33 4.33 4.53 5.71 5.71 5.71 5.71 4.33 4.33 4.33 4.53 H [Inch] 7.87 7.87 7.87 7.87 8.90 8.90 8.90 8.90 8.86 8.86 8.86 8.86
3 x 208-230/440-480
60
1 x 115/230
60
3 x 575 (Canada)
60
CH, CHN 4
Voltage [V] Frequency [Hz] Pump type CH, CHN 4-20 CH, CHN 4-30 CH, CHN 4-40 CH, CHN 4-50 CH, CHN 4-20 CH, CHN 4-30 CH, CHN 4-40 CH, CHN 4-50 CH, CHN 4-20 CH, CHN 4-30 CH, CHN 4-40 CH, CHN 4-50 Motor type ML 71 ML 71 ML 80 ML 80 ML 71 ML 71 ML 80 ML 80 ML 71 ML 71 ML 71 ML 80 L1 [Inch] 12.36 15.04 16.18 17.28 12.36 13.47 16.18 17.28 12.36 13.47 14.57 17.28 L2 [Inch] 3.27 4.33 5.39 6.46 3.27 3.27 4.33 5.39 3.27 3.27 4.33 5.39 L3 [Inch] 2.84 3.90 4.96 6.02 2.84 2.84 3.90 4.96 2.84 2.84 3.90 4.96 L4 [Inch] 4.25 5.32 6.42 7.48 4.25 4.25 5.32 6.42 4.25 4.25 5.32 6.42 B1 [Inch] 5.75 5.75 5.57 5.57 5.75 5.75 5.57 5.57 5.75 5.75 5.75 5.57 B2 [Inch] 4.33 4.33 4.53 4.53 4.33 5.71 5.71 5.71 4.33 4.33 4.33 4.53 H [Inch] 7.87 7.87 7.87 7.87 8.90 8.90 8.90 8.90 7.87 7.87 7.87 7.87
3 x 208-230/440-480
60
1 x 115/230
60
3 x 575 (Canada)
60
20
3.54 90
6.10 155
CH, CHN
CH 8 Rp 1 1/4 B2
CH 12 NPT 1 CH 12 Rp 1 1/2
B1
9.45 240
0.33 8.5
Rp 1/2 L2 L3
5.43 138 6.30 160 4.25 108 5.12 130
TM00 1189 3505
L1
Fig. 7 Dimensional sketches CH, CHN 8and 12 with ML 71/80 motors
CH 8
Voltage [V] Frequency [Hz] Pump type CH 8-20 CH 8-25 CH 8-30 CH 8-40 CH 8-20 CH 8-25 CH 8-20 CH 8-25 CH 8-30 CH 8-40 Motor type ML 71 ML 80 ML 80 ML 80 ML 80 ML 80 ML 71 ML 80 ML 80 ML 80 L1 [Inch] 12.24 15.00 15.00 15.00 13.82 15.00 12.24 15.00 15.00 15.00 L2 [Inch] 2.72 3.90 3.90 3.90 2.72 3.90 2.72 3.90 3.90 3.90 L3 [Inch] 2.28 3.47 3.47 3.47 2.28 3.47 2.28 3.47 3.47 3.47 L4 [Inch] 3.03 4.21 4.21 4.21 3.03 4.21 3.03 4.21 4.21 4.21 B1 [Inch] 6.97 6.97 6.97 6.97 6.97 6.97 6.97 6.97 6.97 6.97 B2 [Inch] 4.29 4.29 4.29 4.29 4.88 4.88 4.29 4.29 4.29 4.29 H [Inch] 7.87 7.87 7.87 7.87 8.90 8.90 9.45 9.45 9.45 9.45
3 x 208-230/440-480
60
60
60
CH 12
Voltage [V] 3 x 208-230/440-480 1 x 115/230 3 x 575 (Canada) Frequency [Hz] 60 60 60 Pump type CH 12-10 CH 12-20 CH 12-10 CH 12-10 CH 12-20 Motor type ML 71 ML 80 ML 71 ML 71 ML 80 L1 [Inch] 12.24 13.82 12.24 12.24 13.82 L2 [Inch] 2.72 2.72 2.72 2.72 2.72 L3 [Inch] 2.28 2.28 2.28 2.28 2.28 L4 [Inch] 3.03 3.03 3.03 3.03 3.03 B1 [Inch] 6.97 6.97 6.97 6.97 6.97 4.29 4.29 B2 [Inch] 4.29 4.29 H [Inch] 9.45 9.45 8.90 9.45 9.45
4.33 110
7.40 188
21
CH, CHN
CH 8 Rp 1 1/4 CH 12 Rp CH 12 NPT111/2
CH 8 NPT 1 1/4
B1
0.33 8.5
L2 L3
L1
CH 8
Voltage [V] 1 x 115/230 Frequency [Hz] 60 Pump type CH 8-30 CH 8-40 Motor type ML 90 ML 90 L1 [Inch] 16.89 16.89 L2 [Inch] 3.90 3.90 L3 [Inch] 3.47 3.47 L4 [Inch] 4.21 4.21 B1 [Inch] 7.52 7.52 B2 [Inch] 5.20 5.20 H [Inch] 8.66 8.66
CH 12
Voltage [V] 3 x 208-230/440-480 1 x 115/230 3 x 575 (Canada) Frequency [Hz] 60 60 60 Pump type CH 12-30 CH 12-20 CH 12-30 Motor type ML 90 ML 90 ML 90 L1 [Inch] 16.89 15.71 16.89 L2 [Inch] 3.90 2.72 3.90 L3 [Inch] 3.47 2.28 3.47 L4 [Inch] 4.21 3.03 4.21 B1 [Inch] 7.32 7.52 7.32 B2 [Inch] 4.88 5.20 4.88 H [Inch] 8.66 8.66 8.66
22
Rp 1/2
4.33 110
7.40 188
CH, CHN
CH, CHN 2-20 CH, CHN 2-30 CH, CHN 2-40 CH, CHN 2-50 CH, CHN 2-60 CH, CHN 4-20 CH, CHN 4-30 CH, CHN 4-40 CH, CHN 4-50 CH, CHN 4-60 CH 8-20 CH 8-25 CH 8-30 CH 8-40 CH 8-50 CH 8-60 CH 12-10 CH 12-20 CH 12-30 CH 12-40 CH 12-50 CH 12-60
CH, CHN 2-20 CH, CHN 2-30 CH, CHN 2-40 CH, CHN 2-50 CH, CHN 2-60 CH, CHN 4-20 CH, CHN 4-30 CH, CHN 4-40 CH, CHN 4-50 CH, CHN 4-60 CH 8-20 CH 8-25 CH 8-30 CH 8-40 CH 8-50 CH 8-60 CH 12-10 CH 12-20 CH 12-30 CH 12-40 CH 12-50 CH 12-60
23
CH, CHN
WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 22 languages. In WebCAPS, all information is divided into 6 sections: Catalog Literature Service Sizing Replacement CAD drawings.
Catalog This section is based on fields of application and pump types, and contains technical data curves (QH, Eff, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc.
Literature In this section you can access all the latest documents of a given pump, such as product guides installation and operating instructions service documentation, such as Service kit catalog and Service kit instructions quick guides product brochures, etc.
Service This section contains an easy-to-use interactive service catalog. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts.
24
CH, CHN
Sizing
This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc.
Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.
CAD drawings In this section it is possible to download 2-dimensional (2D) and 3dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings: .dxf, wireframe drawings .dwg, wireframe drawings. 3-dimensional drawings: .dwg, wireframe drawings (without surfaces) .stp, solid drawings (with surfaces) .eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 22 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year.
Fig. 9 WinCAPS CD-ROM
25
26
27
Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence
L-CH-PG-001
0506
US
Subject to alterations.
GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500
GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Canada Phone: +1-905 829 9533 Telefax: +1-905 829 9512
Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. Mexico 66600 Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010
www.grundfos.com