SC15G

Universal Compressor
R134a
115V 60Hz

Compressors

Data Sheet (Replaces CG.44.A2.22)


General
SC15G

Codenumber

104G7550

Codenumber

104G7551

Codenumber compressor with oil cooler

104G7560

104G

SC15G
Application

R134a

Blue stripe

7550

Barcode on
white background

Application
LBP/HBP
F (C)

Voltage range

-31 to 50 (-35 to 10)

V/Hz

SC15G
115V-60Hz
1PH

103 - 127 /60

Motor type

CSIR

Max. ambient temperature

F (C)

110 (43)
S
O
F1

Comp. cooling at
110F (43C)

O/F1

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temp.
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

8319-4

Evaporating temperature range

max. ambient temperature

DANFOSS COMPRESSORS

Green background

Application

8319-3

Compressor (CU-plated steel connectors)

THERMALLY
PROTECTED

Approval mark

Design
cu.in. (cm3)

Maximum refrigerant charge

20.3 (600)

oz. (g)

45.5 (1300)

Free gas vol. in compressor housing fl.oz. (cm3)

49.4 (1460)

Weight without electrical equipment

27.7 (12.6)

lbs. (kg)

37

37

4.21"(107)

Motor
LRA (rated after 4 sec.UL984) HST

42.0

Cut-in current HST

42.0

Resistance, main and start winding (77F)

1.0/4.3
UL984/CSA-C22.2

Dimensions

104G7550/60
mm

104G7551

8.23 (209)

8.00 (203)

B1

7.20 (183)

B2

3.94 (100)

Suction connector

location/I.D. mm

C 0.320-0.327 (8.20.09) 0.378-0.385 (9.70.09)

Process connector

location/I.D. mm

D 0.252-0.259 (6.50.09) 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. mm

E 0.252-0.259 (6.50.09) 0.252-0.259 (6.50.09)

Oil cooler

location/I.D. mm

F 0.252-0.259 (6.50.09)

September 2003

pcs.

1.18"

0.59"

(30)

(15)

0.12"(3)

Approvals

B A

B1

80

CG.44.A3.22

0.63"(16)

10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)

B2

F
0.75"(19)
0.38"(9.7)

2.76"(70)
5.91"(150)

540

5"(127)
4"(101.6)
1.38"(35)

watt

Compressors on a pallet

8.58"(218)

Motor size

Height

4.21"(107)
4.53"(115)

2.48"(63)

fl.oz. (cm )

Oil quantity

2.48"(63)
2.17"(55)

0.93 (15.30)

5.94"(151)
2.17"(55)

Displacement

5"(127)
6.50"(165)
7.32"(186)

8256

Capacity at LBP conditions (ASHRAE)

Btu/h

Comp.\F -30
-20
-13
-10
0
10
20
30
40
45
50
Comp.\C -34.4 -28.9 -25 -23.3 -17.8 -12.2 -6.7
-1.1
4.4
7.2
10
SC15G
455
780 1088 1241 1837 2570 3440 4448 5595 6222 6884

Capacity at HBP conditions (ASHRAE)


Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC15G
403
692

-13
-25
965

-10
0
10
20
30
40
45
50
-23.3 -17.8 -12.2 -6.7
-1.1
4.4
7.2
10
1100 1628 2276 3045 3934 4945 5496 6078

Capacity (EN 12900/CECOMAF)


Comp.\C -34.4 -28.9
Comp.\F -30
-20
SC15G
109
187

-23.3 -17.8 -12.2


-10
0
10
297
439
614

-6.7
20
821

-1.1
30
106 0

4.4
7.2
10
40
45
50
1331 1479 1635

-13
-25
306

-10
0
10
-23.3 -17.8 -12.2
329 408
486

20
-6.7
566

30
-1.1
645

40
4.4
72 6

45
7.2
766

8222

50
10
807

-13
-10
0
10
-25 -23.3 -17.8 -12.2
4.91 5.02 5.40 5.85

20
-6.7
6.35

30
-1.1
6.91

40
4.4
7.52

45
7.2
7.84

50
10
8.1 8

a2
d

watt

Current consumption
Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC15G
4.45 4.70

watt

-25
-13
260

Power consumption
Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC15G
175 252

Btu/h

c
11

10

12

13
14

Start winding

EER at LBP conditions (ASHRAE)


Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC15G
2.60 3.10

-13
-25
3.56

Btu/Wh

-10
0
10
-23.3 -17.8 -12.2
3.77 4.51 5.28

20
-6.7
6.08

30
-1.1
6.89

40
4.4
7.71

45
7.2
8.12

-10
0
10
-23.3 -17.8 -12.2
3.34 3.99 4.68

20
-6.7
5.38

30
-1.1
6.10

40
4.4
6.81

45
7.2
7.17

-23.3 -17.8 -12.2


-10
0
10
0.90 1.08 1.26

-6.7
20
1.45

-1.1
30
1.64

4.4
40
1.83

7.2
45
1.93

EER at HBP conditions (ASHRAE)


Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC15G
2.31 2.75

-13
-25
3.15

-25
-13
0.85

Winding protector

Btu/Wh

COP (EN 12900/CECOMAF)


Comp.\C -34.4 -28.9
Comp.\F -30
-20
SC15G
0.62 0.74

50
10
8.5 3

Main winding

50
10
7.54

W/W
10
50
2.0 3

Accessories
Devices

Fig.

SC15G

Star ting relay

a2

117U6020

Cover

103N2008

Star ting capacitor 240 F

117U5023

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)

118-1917
118-1918
118-1919

Test conditions
1. Condensing temperature
2. Ambient and suction gas temp.
3. Liquid temperature
Fan cooling F1, 115V 60Hz
ASHRAE
EN 12900/CECOMAF
1. LBP 130F (54,4C) 55C (131F)
2.
90F (32C)
32C (90F)
3.
90F (32C)
55C (131F)
1. HBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)