Você está na página 1de 4

Dynabolt Sleeve Anchors

Solid Concrete Anchoring

Function
The Dynabolt anchor is a general purpose all steel medium duty through xing, torque controlled, sleeve type expansion anchor for masonry and concrete.

Installation

Features and Benets


Improved security Patented sleeve crushes to close gaps up to 5mm and pulls down to induce clamp load. Fast installation Through xing eliminates marking out and repositioning of xtures. Versatile Choice of head styles. Superior corrosion resistance From AISI 316(A4) Stainless Steel. Outstanding exterior durability 42 micron Hot Dip Galvanised coating. Principal Applications Batten xing Formwork support Electrical junction boxes Installing signs, handrails and gates Installing duct work, pipe brackets, cable trays and suspended ceilings Stadium seating Raking angles and corner guards 1. Use xture as a template, drill a hole to the correct diameter and depth. Clean hole thoroughly with brush. 2. Remove debris by way of vacuum or hand pump, compressed air, etc. Insert anchor tightly against xture. 3. Tighten with a spanner. 4. Continue tightening, allowing the sleeve to twist and pull down the xture rmly onto the base material.

16

Dynabolt Sleeve Anchors

Solid Concrete Anchoring


Installation and Performance Details
Installation details Anchor size, dh (mm) Drilled hole , dh (mm) Fixture hole , dF (mm) Anchor effective depth, h (mm) 20 30 30 40 35 50 40 M12 12 15 50 60 55 M16 16 19 70 80 70 M20 20 24 85 100 165 85 55 Tightening torque, Tr (Nm) Minimum Dimensions* Edge distance, ec (mm) 30 55 50 75 50 85 65 90 105 75 105 135 90 130 195 Anchor spacing, ac (mm) 60 105 95 150 100 165 125 180 210 145 210 270 180 255 390 Substrate thickness, bm (mm) 40 70 65 100 70 110 85 120 140 95 140 180 120 170 260 Shear Va (kN) 20 MPa 3.4 3.4 6.0 6.0 10.9 10.9 15.8 15.8 15.8 20.9 20.9 20.9 31.1 31.1 31.1 20 MPa 3.0 5.4 5.4 8.3 6.8 11.7 8.3 11.7 15.3 13.5 19.3 23.6 19.3 25.9 33.0 Reduced Characteristic Capacity Tension Na (kN) Concrete strength (MPa) 32 MPa 3.7 5.4 6.9 9.6 8.6 14.8 10.6 14.8 19.4 17.0 24.4 29.9 24.4 32.7 41.7 40 MPa 4.2 5.4 7.7 9.6 9.7 16.5 11.8 16.5 21.7 19.0 27.3 33.4 27.3 36.6 46.7

M6

10

M8

10

15

M10

10

12

35

* For shear loads acting towards an edge or where these minimum dimensions are not achievable, please use the simplied strength limit state design process to verify capacity. * For details on Reduced Characteristic capacities refer page 3.

Reduced Characteristic

Dynabolt Sleeve Anchors

17

Dynabolt Sleeve Anchors continued


Solid Concrete Anchoring

Description and Part Numbers


Anchor size, db (mm) Length, L (mm) 26 M6 40 60 40 45 M8 65 70 90 40 50 M10 55 75 80 100 60 65 70 M12 75 100 110 125 65 70 M16 110 140 80 M20 115 160 DP16110 DP16140 DP20080 DP20115 DP20160 DP16110GH Nut Head Part No. Zn D6026 DP06040 DP06060 DP08040 DP08065 DP08090 DP10040 DP10050 DP10075 DP10100 DP12060 DP12070 DP12100 DP12125 DP16065 Gal DP10050GH DP10075GH DP10100GH DP12060GH DP12070GH DP12100GH DP12125GH DP16065GH S/S DP06040SS DP06060SS DP08040SS DP08065SS DP10050SS DP10075SS DP10100SS DP12060SS DP12070SS Zn DP08045H DP08070H DP10055H DP10080H DP12065H DP12075H DP12105H DP16070H Hex Bolt S/S DP08070HSS DP10080HSS DP12075HSS -

18

Dynabolt Accessories

Dynabolt Accessories
Solid Concrete Anchoring
These anchors are not recommended for structure critical applications and are typically used for simple xing and nishing applications. Their capacity information is therefore presented in simple Working Load Limit format. Flat

Dynabolt Post Head Anchors:


Decorative nish
d Anchor size (mm) L Anchor length (mm) 34 M6 60 75 100 M8 60 85 75 100 db Thread size M4.5 M4.5 M4.5 M4.5 M6 M6 M8 M8 do Hole x hL Hole depth (mm) 6 x 34 6 x 45 6 x 70 8 x 70 8 x 55 8 x 65 10 x 30 10 x 65 df Fixture Hole x t Nom. Fixt. Thickness 8 x 18 8 x 25 8 x 40 8 x 50 10 x 25 10 x 50 12 x 40 12 x 65 Bolt Style Performance (kN) 32 MPa Tensile Flat Flat Flat Flat Flat Flat Flat Flat 1.8 1.8 1.8 1.8 2.7 2.7 3.8 3.8 Shear 2.5 2.5 2.5 2.5 4.0 4.0 6.4 6.4 Order No. Zn D6034F DP06060F DP06075F DP06100F DP08060F DP08085F DP10075F DP10100F

M10

* For shear loads acting towards an edge or where these minimum dimensions are not achievable, please use the simplied strength limit state design process to verify capacity. * For details on Working Load Limit and Reduced Characteristic capacities refer page 3.

Working Load Limit

Component Set

Eye Bolt

Hook

Set Lock

Tie Wire

Dynabolt Specials:
d Anchor size (mm) L Anchor length (mm) 26 28 31 M8 31 40 M12 db Thread size M4.5 M4.5 M6 M6 M6 M10 do Hole x hL Hole depth (mm) 6 x 30 6 x 41 8 x 40 8 x 40 8 x 45 12 x 50 Bolt Style Set Lok Set Lok Tire Wire Hook Bolt Eye Bolt Component Set Performance (kN) 32 MPa Tensile 0.49 0.74 2.45 0.59 0.59 Order No. Zn D06026S D06038S D08042E D08045K D08045X DC12060 Working Load Limit

M6

* For shear loads acting towards an edge or where these minimum dimensions are not achievable, please use the simplied strength limit state design process to verify capacity. * For details on Working Load Limit and Reduced Characteristic capacities refer page 3.

Round

Flat

Tie Wire

Dynabolt Post Screws:


d Anchor size (mm) M6 L Anchor length (mm) 19 19 23 44 27 52 db Thread size M4.5 M4.5 M6 M6 M8 M10 df Fixture Hole 8 8 10 10 12 15 Head Style Round Flat Flat Tie Wire Flat Tie Wire Order No. Zn REM06 RFM08 REM10 S/S. DR045SS DF045SS DF06SS DF08SS -

M8 M10 M12

19

Você também pode gostar