Você está na página 1de 38

Company Business

Zamil Air Conditioners was founded in 1974, and is the first major business venture in manufacturing sector for the Al
Zamil group of Companies. It is also the first manufacturing unit for air conditioners to be established in Saudi Arabia.
Zamil Air conditioners manufactures both consumer and central range of air conditioners and has sales operations in
over 55 countries in the Middle East, Europe, America, Africa, Australia and the Far East.
The companys operations are structured into four Strategic Business Units (SBUs) supporting six in - house product and
service brands as well as a number of international brands under the OEM sales.
The six in-house brands are Classic, Cooline, CoolCare, Clima Tech, Geoclima and Kessler Clima Tech.
The four SBUs are:
1. Consumer Business unit supporting Classic, Cooline, GE and OEM brands for consumer range of air conditioners.
2. Unitary & Applied Business unit supporting Classic, Cooline, GE and OEM brands for commercial range of air
conditioners.
3. Zamil CoolCare - service and maintenance provider.
4. Geoclima srl - independent business and supporting other SBUs for their requirement of Chillers & Double skin
AHUs.
The first three SBUs - Consumer Products, Unitary & Applied Products and Zamil CoolCare direct their business operations from the corporate headquarters at Dammam, Saudi Arabia.
The production facilities at Dammam are shared by Consumer Products and Unitary & Applied Products. Geoclima has
its own production and functional departments located at Monfalcone, Italy.
All the four SBUs, while operating independently, supplement each others activities in a way that makes synergy work at
its best and achieve the corporate goals of increased productivity and efficiently.
Factories and Productions
Zamil Air Conditioners has its prime manufacturing base at Dammam, Saudi Arabia and has one speciality production
facility in Italy operated by Geoclima.
The company can produce up to 440,000 room air conditioners, 60,000 mini-split systems and 36,500 central air-conditioning systems per year.
Quality & Product Certificates
The Quality systems and policies at Zamil Air Conditioners comply with the required ISO 9001:2000 certification.
Zamil Air Conditioners is the first company in Saudi Arabia to receive the SASO (Saudi Arabias Standard Organization)
certificate for room air conditioners. Its products and services are also certified with:
1.
2.
3.
4.
5.
6.

CE (Council of European Community)


UL (Underwriters Laboratory)
AHAM certificate (Association of Home Appliance Manufacturers)
Eurovent
DEMKO
ETL

Other awards include the prestigious Engineering Excellence Award of General Electric, and the inaugural Prince
Mohammed bin Fahd Al Saud Award for Factory Safety.
Our Products
In addition to the consumer products such as the Room Air Conditioners (RAC) and the Mini Splits, Zamil Air Conditioners manufacturers a host of residential and commercial air conditioners. This board range extends from the concealed
units up to 5 ton, the ducted splits up to 30 tons, the packaged units up to 70 tons. The single and double skin air handling
units up to 130,000 CFM and the water chillers up to 487 ton cooling capacity.

INDEX
Contents

Page

Model decoding ........................................................................................................................................ 2


Blower drive options ................................................................................................................................. 3
Standard specifications/options/accessories ......................................................................................... 3-5
Physical data ......................................................................................................................................... 6-7
Selection procedure ................................................................................................................................. 8
Cooling capacities ............................................................................................................................... 9-12
Electrical data .................................................................................................................................... 13-14
Fan performance data ....................................................................................................................... 15-19
Sound level data ................................................................................................................................ 20-24
Pressure drop/blower motor efficiency ................................................................................................... 25
Unit dimensions ................................................................................................................................. 26-30
Controls and sequence of operation .................................................................................................. 31-32
Typical high and low voltage field wiring connections ............................................................................. 32
Typical schematic wiring diagram ...................................................................................................... 33-34

CONTINUING RESEARCH RESULTS IN STEADY IMPROVEMENTS.


THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Y : 1 HP ODP

060

PT

360

300

240

215

180

**
***

3 HP motor only available for PT120.

Applicable for models PT180 & above only.

P : 15 HP TEFC

N : 15 HP ODP

M : 10 HP TEFC

L : 10 HP ODP

M : 10 HP TEFC

L : 10 HP ODP

K : 7.5 HP TEFC

J : 7.5 HP ODP

K : 7.5 HP TEFC

J : 7.5 HP ODP

H : 5 HP TEFC

G : 5 HP ODP

F : 3 HP TEFC

D : 2 HP ODP

D : 2 HP ODP

C : 1.5 HP ODP

E : 3 HP ODP

D : DUAL

S : SINGLE

8
BLOWER
MOTOR

100

L : 380/415-3-50
(4 WIRE)

7
REFRIGERATION CIRCUIT

120***

090

075

6
ELECTRICAL
SUPPLY
( V-Ph-Hz )

NOTE: * Applicable for PT075 models only.

COOLINE
PACKAGED
UNIT

3, 4 & 5
NOMINAL
COOLING
CAPACITY
(MBH)

MODELS: PT075 - PT360 (BELT DRIVEN MOTOR)

W : 0.75 HP ODP

1& 2
BASIC

9
DRIVE
OPTIONS

10
HEATER
OPTIONS
(kW/STAGE)
11
EVAPORATOR
COIL
12
CONDENSER
COIL

13
PDS
OPTION

K : ALT. II

J : ALT. I

9
DRIVE
OPTIONS
N
A
B
C
D
E
F
G
C
D
E
F
G
H
J

:
:
:
:
:
:
:
:
:
:
:
:
:
:
:

11
EVAPORATOR
COIL

L : IGT + CORRUGATED CU. FINS

12
CONDENSER
COIL

L : IGT + CORRUGATED CU. FINS

13
PDS
OPTION

K : IGT + ENHANCED K : IGT + ENHANCED P : PDS OPTION


MHG. FINS
MHG. FINS

NO HEATER J : IGT + ENHANCED J : IGT + ENHANCED N : NO PDS


5/1*
OPTION
AL. FINS
AL. FINS
6/1*
7.5/1
K : IGT + ENHANCED K : IGT + ENHANCED P : PDS OPTION
10 /2
MHG. FINS
12/2
MHG. FINS
15 /2
20 /2
L : IGT + CORRUL : IGT + CORRU7.5/1
GATED CU. FINS
GATED CU. FINS
10 /2
12/2
15 /2
20 /2
25/2
30/2**

10
HEATER
OPTIONS
(kW/STAGE)

E : 12/2

D : 10 /2

C : 7.5/1

B : 6/1

W : 0.75 HP ODP N : DIRECT N : NO HEATER J : IGT + ENHANCED J : IGT + ENHANCED N : NO PDS


OPTION
AL. FINS
AL. FINS
DRIVE
A : 5/1

8
BLOWER
MOTOR

048

S : SINGLE

7
REFRIGERATION CIRCUIT

036

L : 380/415-3-50
(4 WIRE)

6
ELECTRICAL
SUPPLY
( V-Ph-Hz )

PT

3, 4 & 5
NOMINAL
COOLING
CAPACITY
(MBH)

COOLINE
PACKAGED
UNIT

1& 2
BASIC

MODELS: PT036 - PT060 (DIRECT DRIVE MOTOR)

MODEL DECODING
15
UNIT
ACCESSORIES

15
UNIT
ACCESSORIES

C : FRESH AIR
MANUAL
DAMPER

V : VOLT FREE
CONTACT

U : UVM

I : ANTI-ICE

C : FRESH AIR
MANUAL
DAMPER

N : STANDARD UNIT N : STANDARD UNIT

14
OTHER
OPTIONS

V : VOLT FREE
CONTACT

U : UVM

I : ANTI-ICE

N : STANDARD UNIT N : STANDARD UNIT

14
OTHER
OPTIONS

BLOWER DRIVE OPTIONS


MOTOR
MODEL
NUMBER

OPTION

PT075
PT090
PT100
PT120
PT180
PT215
PT240
PT300
PT360

ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II

BLOWER

HP

RPM

1.5
2

1450
1450
1450
1450
1450
1450
1450
1450
1450
1450

PULLEY
PITCH DIA.
(INCH)
2.7 - 3.7
2.7 - 3.7
2.7 - 3.7
2.7 - 3.7
2.7 - 3.7
2.7 - 3.7
3.1 - 4.1
3.1 - 4.1
3.7 - 4.7
4.3 - 5.5

1450
1450
1450

2/3
2/3
3
5
7.5
5
7.5
7.5/10
7.5/10

SPEED RANGE (RPM)

PULLEY
PITCH DIA.
(INCH)
4.6
4.1
6.1
4.6
6.1
4.6
6.1
5.1
7
7
9.4

APPROX. SPEED
CHANGE PER
PULLEY TURN
(RPM)

MINIMUM

MAXIMUM

4.3 - 5.5

851
955
642
851
642
851
737
881
766
891
663

1166
1309
880
1166
880
1166
975
1166
974
1139
848

4.3 - 5.5

779

997

36

4.3 - 5.5

663

848

9.4

31

1450

4.3 - 5.5

779

997

36

1450

4.8 - 6.0

740

926

9.4

31

1450

4.8 - 6.0

870

1088

36

53
59
40
53
40
53
40
47
35
41
31

ALT. I

10

1450

4.8 - 6.0

740

926

9.4

31

ALT. II

15

1450

4.8 - 6.0

870

1088

36

STANDARD SPECIFICATIONS
A. General
Packaged cooling or combination heating and cooling units suitable for mounting on the roof or ground. The packaged
unit consists of hermetic compressors, cooling coil, condenser coil, control wiring and interconnecting piping - all factory
assembled and mounted on heavy gauge G-90 galvanized steel sheet press formed base, ready for field connection to
utilities and ducts. The packaged unit is of rigid construction with holes provided in the base rails for overhead rigging.
The unit is provided with an integral weather resistant control panel.
These units are rated and tested in accordance with ARI standard 210/ ARI 360.

B. Unit Enclosure
Panels are of heavy gauge, G-90 galvanized steel sheet with removable access panels, completely weatherized for
outdoor installation and properly reinforced and brazed. Panels and access doors are provided for inspection and access
for all internal parts. Enclosures are provided with adequately reinforced points of support for setting the unit. Steel sheet
panels are zinc-coated and galvanized by the hot dip process of lock forming quality conforming to ASTM A 653 commercial weight G-90, followed by baked on electrostatic polyester dry powder coat paint, on all external panels.

C. Compressor
Compressors are hermetic reciprocating for PT036 - PT060 & PT090 - PT120 (dual) and hermetic scroll for all other
models as standard. They are provided with all the standard controls and accessories necessary for safe operation.
These are equipped with internal motor protector, factory installed crank case heater and rubber vibration isolator for
quiet and efficient operation.

D. Air Cooled Condensing Section


1. The air-cooled condensing section is enclosed within the unit housing and consists of condenser coil, fan(s), electric
motor(s) and inherently protected compressor(s). Inner grooved copper tubes with wall thickness of 0.0175 inches
(0.445 mm), mechanically bonded to enhanced louvered aluminum fins are standard for all condenser coils. Return
bends have 0.022 inch thickness (0.56 mm). As an option, corrugated copper fins or enhanced coated aluminum
fins may be provided. Tube support sheets are galvanized steel, formed to provide structural strength.
2. Fans are propeller type, direct driven, upward discharge and provided with fan grille mounted on the casing.
3. Motors are totally enclosed air-over type with class F insulation. Inherent thermal protection is automatic reset type.

E. Evaporator Coil Section


1. All cooling coils are of enhanced fins and inner grooved copper tubes with wall thickness of 0.0175 inches (0.445mm),
mechanically bonded to aluminum fins. Return bend has 0.022 inch thickness (0.56 mm). As option, enhanced
coated aluminum fins or corrugated copper fins may be provided. Tube support sheets are galvanized steel,
formed to provide structural strength.
2. Drain Pan: An insulated drain Pan made of G-90 galvanized steel is provided, for additional corrosion protection,
mastic coated lining is provided as the surface.
3. Insulation: Insulation is supplied in adequate density and thickness for all units to prevent condensation from forming
on the unit casing. Insulation meets the requirements of NFPA 90A and is protected against deterioration and erosion
from air currents.

F. Evaporator Fan
PT036 - PT060: Evaporator fan is of a centrifugal forward-curved blade design and sized to meet system airflow/pressure
using direct drive motors. These fans are statically / dynamically balanced in the fan housing during final assembly. Fan
motors have ball bearings and conform to NEMA MG-1 & MG-2. Motor starters are magnetic contactor, across-the-line type.
PT075 - PT360: Evaporator fan is of centrifugal forward-curved blade design capable of handling total required CFM and
static pressure in the low and the medium ranges. Casings are made of galvanized steel. Blower motors are of the open drip
proof type (totally enclosed types are optional) and conform to NEMA MG-1 and MG-2. Fan drive is through adjustable
pitch pulleys and belt driven. Blower motor is mounted on adjustable base and secured by locking device. Fan wheels shafts
and bearing are selected to operate at 25% below first critical speed. Pillow block bearings are selected for at 200,000 hours
average life at design operating conditions. Shaft is turned, ground and polished from solid steel. Fans and pulleys are keyed
to shaft and designed for continuous operation at maximum motor horse power and fan speed. All rotating components and
assemblies are statically and dynamically balanced and every unit is vibration tested before shipment from the factory.

G. Performex-1TM Controller Electronic Control Board


The COOLINE Packaged units are provided with technologically advanced new Performex-1TM Controller Microprocessor Based Electronic Control Board, incorporating the following benefits and features:
- COMPLETE UNIT CONTROL: Provides complete unit control for heating and cooling application whether single
stage or two stage utilizing the input from sensor that measure temperatures during unit operation.
- COMPRESSOR LOCKOUT: If any of the units safety controls trip due to abnormal conditions the Electronic Control
locks out the compressor, preventing restart, unless attended by qualified service technicians. The unit can be restarted only by reset the thermostat after ensuring safe system conditions.
- LEAD LAG OPERATION: The unit electronic controls automatically alternate lead and lag the compressors for even
operation. Compressor #1 can be set always lead as an option.
- ANTI-RECYCLE TIMER: For compressor safety in case of accidental manual reset or immediate recycling of thermostat due to load demand. This considerably improves compressor life.
- PUMP DOWN OPTION: In units equipped with pump down system the time delay creates the required time gap between
the solenoid opening and compressor start to equalize the pressure in the system prior to compressor start up.
- AUTO/MANUAL RESET OF THE ALARM SIGNALS.
- FULL CONTROL OF THE INDOOR FAN: Fan operation can be selected either to run continuously or stage with the
compressor/heaters.

H. Electronic Thermostats
General information: A dedicated electronic thermostat is supplied with the unit controls as standard. This thermostat
controls one or two stage heating and cooling applications. The thermostat normally displays room temperature and
mode of operation.
The temperature can be set by up/down buttons for both cooling and heating cycles. The thermostat also allows you to
select continuous fan operation, or have the fan on intermittent operation with the equipment. It also displays the status
of the unit, thus providing maximum information for the end user. As this is a dedicated thermostat supplied with the unit
controller, the said controls can not be connected to any other BMS or DDC controller.
Special controller to be used, if required, for BMS or DDC controller connections.
4

OPTIONS AND ACCESSORIES


A. Electric Heaters
Electric heaters are of the resistance open coil type and conform to the requirements of UL 573 or equivalent. Electrical
characteristics, kW capacities and number of stages are as indicated. Airflow switches, fusible links and overheat limit thermostats are provided to shut-off power in case of airflow failure/overheat. Electric heater kit is installed as an externally
mounted kit at the supply opening.

B. UV FlowTM Light Emitters:


The damp & dark environment inside the unit could contribute for the growth and development of hazardous bacteria and
TM
fungi. The UV flow concept uses emitter of Ultra Violet to simulate the effect of healthy sun radiation. This will inhibit the
TM
growth of these microorganism reducing in this manner mold related allergies and diseases. Breath safely with UV flow .
TM

To order UV flow use the kit number in tables below:


MODEL No.

PT036 - 060

PT075

PT090 - 120

PT180

PT215 - 240

PT300 -360

KIT PART No.

700-393-00

700-393-01

700-393-02

700-393-03

700-393-04

700-393-05

STANDARD FEATURES/OPTIONS/ACCESSORIES
STANDARD
FEATURES

DESCRIPTION
Horizontal discharge
Compressor crankcase heaters
Evaporator fanbelt driven(1)
Evaporator fan motor ODP type (TEFC type optional)(2)
Condenser fan direct drive, propeller type
Condenser fan motor totally enclosed air-over type
Electric heaters
Filter drier
Return air filter
Compressor overload protection
Low pressure switch
High pressure switch
Cooling & heating thermostat
Condenser fan guard
Condenser coil guard
Manual outside air damper
NOTES:
(1) Direct drive motors for PT036 to PT060.
(2) TEFC motors are available for PT090 to PT360.

OPTION
(FACTORY
INSTALLED)

ACCESSORY
(FIELD
INSTALLED)

PHYSICAL DATA
(DIRECT DRIVE MOTOR)
MODEL NUMBER

PT036

PT048

PT060

NOMINAL CAPACITY, TONS (kW)

3 (10.5)

4 (14)

5 (17.5)

Quantity

Oil (oz)

40

70

70

COMPRESSOR

Refrigerant

R-22

Operating Charge (oz)


CONDENSER FAN

81

Type/Drive

Nominal CFM (L/S)


Motor HP RPM

1 24

1 24

1 24

3500 (1652)

3500 (1652)

3500 (1652)

1/3 1075

1/3 1075

1/3 1075

Inner Grooved Tubes and Enhanced Fins

Type
Tube dia. - Rows - Fins per inch
Total face area, Sq. ft. (Sq. m.)

EVAPORATOR BLOWER

3/8-1-14

3/8-2-14

3/8-2-16

10.4 (0.97)

8.33 (0.774)

10.4 (0.97)

Type

Centrifugal

Size (inch)

10 x 10

10 x 10

Drive type

10 x 10

Direct Drive

Nominal CFM (L/S)


Motor HP (Standard)
EVAPORATOR COIL

134

Propeller/Direct

Quantity Diameter (inch)

CONDENSER COIL

95

1200 (566)

1600 (755)

1800 (850)

0.5

0.75

0.75

Type

Inner Grooved Tubes and Enhanced Fins

Tube dia. - Rows - Fins per inch

3/8-2-16

Total face area, Sq. ft. (Sq. m.)

3.82 (0.35)

3/8-2-16

3/8-3-14

3.82 (0.35)

4.86 (0.45)

LOW PRESSURE
SWITCH

Open

25 5 PSIG

Close

50 5 PSIG

RETURN AIR FILTERS


(1'' THICK)

Quantity

SHIPPING WEIGHT

Kgs.

Size (inch)

20 x 12.75

20 x 12.75

20 x 12.75

182

190

198

PHYSICAL DATA
MODEL NUMBER

PT075

PT090

PT100

PT120

PT180

PT215

PT240

PT300 PT360

6 (21)

7.5 (26)

8.5 (30)

10 (35)

15 (53)

18 (63)

20 (71)

25 (88) 30 (105)

Quantity

Oil (oz)

60

45 x 2

70 x 2

60 x 2

110 x 2

140 x 2

140 x 2

282 x 2

388 x 2

425 x 2

2 26

4 24

4 24

NOMINAL CAPACITY, TONS (kW)


COMPRESSOR

Refrigerant
Operating Charge per system (oz)
CONDENSER FAN

R-22
159

99 x 2

126 x 2

134 x 2

Type/Drive
Qty. Diameter (inch)
Nominal CFM (L/S)

81 & 110 110 x 2

195 & 210 278 x 2

Propeller/Direct
1 24

1 26

1 26

5100(2410)

6600(3115)

6600(3115)

1 26

2 24

2 26

6600(3115) 11500(5430) 13400(6330) 13400(6330) 22300(10535)22300(10535)

Motor HP RPM

3/4 950

CONDENSER COIL Type

Inner Grooved Tubes and Enhanced Fins

Tube dia. - Rows - Fins per inch 3/8-2-16 3/8-1-16 3/8-2-14 3/8-2-14 3/8-2-14 3/8-2-16 3/8-2-16 3/8-2-14 3/8-2-14
Total face area, Sq. ft. (Sq. m.) 11.66 (1.08) 22.5 (2.1) 22.5 (2.1) 22.5 (2.1) 36 (3.36) 48 (4.5)
EVAPORATOR
BLOWER

Type
Size (inch)

48 (4.5) 72 (6.71) 72 (6.71)

Centrifugal
12 x 12

15 x 15

15 x 15

15 x 15

Drive type

15 x 15

18 x 18

18 x 18

18 x 18

18 x 18

9600(4535) 11250(5315)

Belt

Nominal CFM (L/S)

2400(1135)

3000(1415)

3400(1605)

4000(1890)

6000(2835)

7000(3305)

7500(3540)

Motor HP - Std. / Alt

1.5/2

2/3

2/3

5/7.5

5/7.5

7.5/10

Motor Frame (NEMA) Std. / Alt.

56 / 56

56 / 56

56 / 56

56

750-1200

700-1200

700-1200

700-1200

700-1150

700-1150

700-1150

700-1250

700-1250

4.6

6.1

6.1

6.1

7.0

9.4

9.4

9.4

9.4

Fan RPM range


Factory setting full turns open
Fan pulley pitch dia.
EVAPORATOR COIL Type

7.5/10

10/15

184T/213T 184T/213T 213T/215T 213T/215T 213T/254T

Inner Grooved Tubes and Enhanced Fins

Tube dia. - Rows - Fins per inch 3/8-3-14 3/8-2-16 3/8-3-14 3/8-3-14 3/8-3-14 3/8-3-14 3/8-3-14 3/8-3-14 3/8-4-14
Total face area, Sq. ft. (Sq. m.) 5.47 (0.51) 8.94 (0.83)
LOW PRESSURE
SWITCH

8.94 (0.83)

8.94 (0.83) 13.33 (1.24)

Open

25 5 PSIG

Close

50 5 PSIG

RETURN AIR
Qty.
FILTERS (1'' THICK)
Size (inch)
SHIPPING WEIGHT Kgs.

22.5x12.8

27.5x17

27.5x17

27.5x17

246

367

383

384

16 (1.48)

17.67 (1.64) 20.67 (1.92) 20.67 (1.92)

26.5x38.6 24.75x 23 24.75x 23 27x 26.6


695

742

760

1060

4
27x 26.6
1176

SELECTION PROCEDURE
1. Determine cooling and heating capacity requirements at design conditions
Data:
Condenser entering air temperature
Evaporator entering air temperature
Evaporator airflow
Required cooling capacity
Sensible heat capacity
Required heating capacity
External static pressure
Power supply (V-Ph-Hz)

: 1150F
: 800F DB / 670F WB
: 7500 CFM
: 196,000 BTUH
: 145,000 BTUH
: 20 kW
: 0.8 INCH WG.
: 380/415-3-50

2. Unit selection based on required cooling capacity


Enter cooling capacity performance data at condenser entering air temp. at 1150F and evaporator entering air temp.
800F DB, 670F WB, 7500 CFM airflow. The PT240 unit will give 212,660 BTUH cooling capacity (gross) and 160,310 BTUH
sensible heat capacity (gross).

3. Electric heater selection


Heating capacity required =20 kW.
Enter electric heating table for PT240 at 380/415-3-50 power supply.
20 kW heater at 380/415 volts satisfies the required heating.

4. Determine fan speed and power requirements at design conditions


Before entering the fan performance tables, calculate the summation of external static pressure for the required components as follows.
External static pressure
Electric heater

: 0.8 INCH WG.


: 0.14 INCH WG.
0.94 INCH WG.

Enter fan performance table for PT240 model. For 7500 CFM and external static pressure of 0.94 INCH WG, it require
830 RPM and 4.58 brake horse power (BHP) wherein the standard motor will meet job requirements.

5. Determine input power to motor


Use fan motor efficiency table.
BHP x 746 watts
Blower motor watts =
=
Motor efficiency

4.58 x 746
0.81

= 4218 watts.

6. Determine net capacities


Above capacities are gross and do not include blower motor heat gain.
Determine net capacities as follows:
Net cooling capacity
= Gross cooling capacity blower motor heat
= 212,660 (4218 WATTS x 3.413 BTUH/WATTS) = 198,264 BTUH
Net sensible capacity = 160,310 (4218 WATTS x 3.413 BTUH/WATTS) = 145,914 BTUH

7. Altitude correction factors for cooling capacity


ALTITUDE, FT.
FACTOR

2000

4000

6000

8000 10000

Total capacity

0.98

0.96

0.93

0.90

0.88

Sensible capacity

0.93

0.86

0.80

0.75

0.70

COOLING CAPACITIES
Model No.: PT036
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

1135/0.235
62
32.34
30.66
3.44
31.29
30.25
3.49
30.09
29.76
3.67
27.94
27.58
3.88
25.86
25.79
4.07

67
35.63
25.47
3.61
34.52
25.09
3.67
33.22
24.61
3.87
30.89
23.53
4.09
28.62
22.93
4.3

72
39.16
20.21
3.78
37.96
19.83
3.85
36.56
19.37
4.06
34.06
18.39
4.31
31.59
17.76
4.54

EVAPORATOR AIRFLOW, CFM/DR


1250/0.248
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
32.97
36.31
39.87
32.12
26.55
20.9
3.53
3.7
3.87
31.87
35.15
38.67
31.57
26.15
20.53
3.58
3.76
3.93
30.6
33.84
37.24
30.32
25.67
20.07
3.76
3.96
4.15
28.48
31.47
34.68
28.12
24.59
19.07
3.96
4.19
4.39
26.3
29.14
32.13
26.24
23.98
18.43
4.17
4.4
4.64

1370/0.260
62
33.47
33.11
3.6
32.39
32.09
3.65
31.07
30.78
3.85
28.9
28.53
4.06
26.7
26.63
4.26

67
36.89
27.56
3.77
35.76
27.2
3.83
34.38
26.69
4.04
31.99
25.6
4.26
29.62
25.01
4.49

72
40.57
21.59
3.94
39.3
21.2
4.01
37.87
20.74
4.24
35.28
19.75
4.49
32.68
19.09
4.73

Model No.: PT048


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

1275/0.250
62
41.69
37.75
5.11
40.6
37.18
5.16
38.62
36.45
5.26
36.45
35.73
5.46
34.32
33.64
5.54

67
45.76
32.22
5.44
44.58
31.65
5.49
42.46
30.92
5.6
40.05
30.12
5.81
37.79
29.04
5.91

72
50.05
26.53
5.74
48.82
26
5.8
46.53
25.24
5.93
43.93
24.43
6.15
41.49
23.38
6.28

EVAPORATOR AIRFLOW, CFM/DR


1450/0.268
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
45.49
49.94
54.62
45.04
37.67
30.12
5.41
5.67
5.93
44.24
48.62
53.22
43.35
37.08
29.57
5.6
5.88
6.15
42.04
46.2
50.66
41.2
36.32
28.82
5.69
5.98
6.27
39.61
43.62
47.87
38.82
35.62
28.06
5.87
6.18
6.5
37.33
41.12
45.23
36.59
34.5
27.03
5.96
6.28
6.61

1650/0.280
62
46.19
45.26
5.74
44.97
44.07
5.66
42.7
41.85
5.74
40.26
39.46
5.93
37.91
37.15
6.02

67
50.72
38.69
6.02
49.42
38.13
5.93
46.99
37.41
6.04
44.31
36.67
6.24
41.79
35.56
6.34

72
55.52
30.81
6.29
54.14
30.29
6.21
51.55
29.55
6.32
48.71
28.8
6.56
45.95
27.72
6.67

Model No.: PT060


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

1600/0.120
62
55.49
48.13
6.22
52.34
45.81
6.68
49.61
43.41
6.97
44.36
38.13
7.19
41.29
35.85
7.45

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
60.71
41.44
6.5
57.44
40.62
7.0
54.47
39.8
7.3
48.82
36.13
7.56
45.42
35.2
7.84

72
66.41
32.7
6.74
62.86
31.86
7.28
59.74
31.05
7.62
53.51
27.96
7.91
49.93
27.1
8.22

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


1800/0.135
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
56.01
61.37
67.06
48.58
42.67
33.46
6.4
6.66
6.91
52.88
58.03
63.52
46.27
41.83
32.64
6.88
7.18
7.46
50.15
55.05
60.39
43.89
41.03
31.85
7.15
7.48
7.8
44.81
49.3
54.11
38.52
37.24
28.72
7.38
7.74
8.1
41.67
45.88
50.43
36.16
36.34
27.81
7.65
8.02
8.41
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

2000/0.150
62
57.01
49.45
6.46
53.87
47.14
6.93
51.05
44.67
7.2
45.63
39.23
7.44
42.46
36.85
7.7

67
62.51
45.03
6.72
59.04
44.15
7.23
56.13
43.46
7.53
50.18
39.45
7.79
46.7
38.55
8.08

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input at 0.15 ESP for PT036 & 0.2 ESP for PT048/PT060.

72
68.38
35.01
6.96
64.69
34.15
7.52
61.49
33.38
7.86
55.09
30.13
8.15
51.41
29.27
8.48

COOLING CAPACITIES
Model No.: PT075
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

1900/0.13
62
66.53
57.17
7.17
65.28
56.4
7.56
58.9
52.68
7.72
55.98
51.84
8.68
53.47
51.04
9.3

67
72.72
47.83
7.34
71.49
47.04
7.73
64.58
43.88
7.87
61.43
43.0
8.86
58.77
42.21
9.48

72
79.47
38.42
7.51
78.2
37.56
7.9
70.79
35.0
8.04
67.34
34.06
9.03
64.52
33.28
9.7

EVAPORATOR AIRFLOW, CFM/DR


2400/0.16
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
69.83
76.44
83.56
65.32
53.91
42.38
7.55
7.7
7.89
65.87
72.22
79.17
63.53
53.15
41.61
7.91
8.08
8.25
61.8
67.81
74.41
58.6
49.65
38.77
8.04
8.19
8.37
58.62
64.44
70.86
55.98
48.76
37.9
9.02
9.2
9.4
56.06
61.69
67.83
53.81
48.04
37.09
9.63
9.82
10.06

2900/0.18
62
72.16
68.25
8.06
67.99
65.58
8.4
63.78
60.48
8.5
60.55
57.82
9.5
57.83
55.51
10.12

67
79.05
59.46
8.21
74.71
58.78
8.55
70.11
54.95
8.66
66.66
54.13
9.67
63.7
53.35
10.3

72
86.56
45.99
8.41
81.92
45.22
8.76
77.06
42.22
8.86
73.26
41.3
9.91
70.19
40.56
10.56

Model No.: PT090


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

2400/0.20
62
80.31
70.32
8.37
77.8
69.86
8.97
73.31
67.87
9.44
69.75
66.94
9.98
65.05
64.9
10.65

67
88.23
59.41
8.79
85.53
58.87
9.44
80.64
56.9
9.97
76.79
55.88
10.56
71.69
53.89
11.29

72
96.52
48.19
9.2
93.62
47.59
9.88
88.34
45.66
10.46
84.21
44.59
11.11
78.72
42.66
11.9

EVAPORATOR AIRFLOW, CFM/DR


3000/0.23
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
83.79
92.08
100.73
77.74
64.93
51.81
8.93
9.34
9.72
81.05
89.22
97.63
77.27
64.44
51.2
9.55
10.02
10.46
76.34
84.02
92.07
75.29
62.41
49.26
10.04
10.56
11.04
72.55
79.86
87.67
71.1
61.35
48.19
10.58
11.16
11.71
67.71
74.65
81.98
66.36
59.45
46.28
11.28
11.9
12.52

3600/0.26
62
86.27
83.8
9.61
83.45
83.41
10.27
78.59
77.02
10.77
74.67
73.17
11.32
69.65
68.25
12.01

67
94.73
69.35
10.02
91.77
68.9
10.72
86.46
66.92
11.28
82.25
65.96
11.89
76.79
63.99
12.64

72
103.66
54.67
10.4
100.55
54.15
11.17
94.81
52.21
11.77
90.31
51.18
12.44
84.41
49.25
13.27

Model No.: PT100


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

2700/0.115
62
94.47
85.68
9.43
90.24
84.18
9.85
86.35
82.19
10.14
82.24
80.2
10.61
76.94
75.4
10.84

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
103.36
71.97
9.93
98.99
70.83
10.38
94.81
68.64
10.72
90.36
66.71
11.25
84.75
64.71
11.51

72
112.89
58.05
10.39
108.25
57.17
10.89
103.81
54.83
11.27
99.04
52.98
11.85
92.99
51.0
12.15

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


3400/0.135
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
98.96
108.49
118.56
97.23
80.64
63.73
9.86
10.34
10.79
94.57
103.86
113.67
95.63
79.37
62.76
10.29
10.81
11.32
90.37
99.35
108.89
88.56
77.24
60.46
10.6
11.16
11.72
86.07
94.63
103.91
84.35
75.25
58.61
11.09
11.71
12.31
80.59
88.73
97.46
78.98
73.28
56.59
11.32
11.98
12.62
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

4100/0.165
62
102.19
100.14
10.48
97.58
99.62
10.91
93.25
91.39
11.23
88.79
87.01
11.74
83.07
81.41
11.98

67
112.16
88.55
10.95
107.32
87.14
11.43
102.56
85.07
11.8
97.76
83.13
12.37
91.72
81.24
12.63

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.25 ESP.

10

72
122.65
68.84
11.38
117.57
67.79
11.94
112.57
65.56
12.35
107.27
63.62
12.99
100.73
61.68
13.3

COOLING CAPACITIES
Model No.: PT120
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

3200/0.128
62
112.23
96.8
11.99
106.3
94.65
12.78
100.76
90.91
13.75
96.17
89.2
14.17
91.43
89.27
14.72

67
122.24
81.3
12.3
115.99
79.39
13.1
109.94
75.87
14.09
104.96
74.15
14.52
99.85
74.9
15.12

72
133
65.3
12.55
126.17
63.77
13.36
119.61
60.52
14.37
114.26
58.82
14.81
108.91
59.36
15.46

EVAPORATOR AIRFLOW, CFM/DR


4000/0.160
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
116.99
127.55
138.77
108.8
90.2
71.3
12.6
12.85
13.09
110.74
120.94
131.62
106.48
88.17
69.44
13.38
13.65
13.91
104.82
114.55
124.76
102.49
84.5
66.13
14.35
14.64
14.91
100.08
109.34
119.24
99.0
82.81
64.49
14.75
15.06
15.35
95.19
103.95
113.39
94.24
82.75
64.03
15.3
15.7
16.05

4800/0.180
62
120.3
118.5
13.38
114.01
113.1
14.16
107.93
106.42
15.12
102.86
101.75
15.52
97.79
96.81
16.18

67
131.43
98.3
13.63
124.54
96.15
14.43
117.88
92.32
15.41
112.43
90.6
15.8
106.98
90.83
16.48

72
143.17
76.6
13.85
135.66
74.59
14.67
128.64
71.24
15.66
122.82
69.56
16.09
116.8
69.24
16.76

Model No.: PT180


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

4800/0.130
62
164.27
146.19
18.02
158.28
141.45
19.19
149.87
136.78
20.22
142.32
132.02
22.11
133.51
124.6
23.41

67
178.45
121.58
18.39
172.27
117.42
19.57
163.45
113.19
20.61
155.29
108.74
22.53
145.96
104.65
23.85

72
193.87
96.83
18.75
187.29
93.13
19.94
177.64
89.1
20.99
169.09
85.16
22.93
159.02
81.42
24.29

EVAPORATOR AIRFLOW, CFM/DR


6000/0.160
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
170.42
185.28
201.49
164.71
135.21
105.61
19.4
19.75
20.14
164.33
178.94
194.63
157.04
130.94
101.79
20.56
20.93
21.32
155.47
169.56
184.76
147.32
126.46
97.78
21.57
21.94
22.37
147.71
161.3
175.72
138.21
122.01
93.67
23.45
23.85
24.31
138.63
151.57
165.37
129.41
117.74
89.89
24.75
25.16
25.66

7200/0.180
62
174.92
169.67
21.16
168.6
161.13
22.32
159.62
151.27
23.32
151.64
141.89
25.19
142.3
132.84
26.5

67
190.57
147.91
21.52
183.96
143.38
22.69
174.03
138.59
23.7
165.43
133.91
25.58
155.68
129.69
26.91

72
207.25
113.66
21.91
200.01
109.62
23.12
189.81
105.54
24.14
180.6
101.38
26.09
169.77
97.4
27.45

Model No.: PT215


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

5800/0.140
62
198.66
174.67
20.41
190.22
167.28
21.74
177.47
158.3
22.98
165.64
156.27
23.91
154.37
152.46
26.04

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
215.61
147.05
21.17
206.28
140.16
22.5
192.5
131.98
23.73
179.82
129.56
24.65
167.76
125.88
26.81

72
232.9
118.6
21.76
222.94
112.46
23.07
208.39
105.25
24.31
194.62
102.4
25.21
181.57
98.72
27.39

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


7000/0.160
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
206.4
223.64
241.38
192.5
160.05
126.91
21.82
22.5
23.05
197.36
213.8
231.02
184.59
152.84
120.63
23.11
23.8
24.33
183.96
199.46
215.76
175.06
144.32
113.17
24.33
25.0
25.54
171.64
186.36
201.64
168.84
142.26
110.58
25.21
25.89
26.41
159.97
173.78
188.14
155.65
138.56
106.94
27.32
28.01
28.55
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

8200/0.180
62
211.97
208.69
23.22
202.7
200.53
24.49
188.92
186.86
25.68
176.13
173.26
26.52
164.34
159.9
28.62

67
229.69
171.99
23.85
219.47
164.5
25.12
204.94
155.86
26.3
191.23
153.86
27.14
178.37
150.25
29.24

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.35 ESP.

11

72
248.02
134.61
24.37
237.22
128.11
25.63
221.61
120.53
26.82
207.01
118.05
27.65
193.08
114.41
29.78

COOLING CAPACITIES
Model No.: PT240
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

6000/0.125
62
221.76
190.52
23.85
212.58
181.68
25.48
196.86
175.75
27.34
187.98
172.73
29.25
174.73
170.96
30.32

67
240.16
159.58
24.62
230.52
152.31
26.24
213.7
146.56
28.12
204.15
143.67
30.04
189.99
140.59
31.1

72
259.52
128.19
25.2
249.37
122.44
26.83
231.2
116.79
28.73
221.28
114.16
30.67
205.96
110.66
31.74

EVAPORATOR AIRFLOW, CFM/DR


7500/0.150
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
231.18
250.39
270.57
214.06
177.02
139.41
25.03
25.71
26.28
221.49
240.28
259.66
204.14
168.94
132.99
26.65
27.32
27.89
205.12
222.54
240.88
198.33
163.14
127.5
28.49
29.17
29.78
195.7
212.66
230.23
195.2
160.31
124.73
30.37
31.09
31.72
181.95
197.75
214.49
179.62
157.45
121.55
31.42
32.14
32.78

9000/0.175
62
237.89
234.05
26.56
227.82
222.76
28.15
210.8
208.24
29.99
201.39
200.17
31.86
187.15
184.75
32.9

67
257.55
192.74
27.18
247.09
183.95
28.77
228.85
178.22
30.62
218.9
175.59
32.52
203.23
172.78
33.57

72
278.41
149.47
27.77
267.53
142.78
29.38
247.67
137.06
31.26
237.19
134.56
33.18
220.89
131.54
34.26

Model No.: PT300


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

8000/0.140
62
271.43
244.87
28.43
262.81
242.0
31.4
247.49
239.16
33.37
234.6
232.24
35.9
215.56
213.4
37.71

67
293.99
204.24
29.17
285.06
201.55
32.15
268.44
198.59
34.16
254.57
192.0
36.73
234.18
186.16
38.6

72
317.52
162.83
29.72
307.93
160.09
32.71
290.34
157.29
34.76
275.52
151.11
37.37
254.12
145.68
39.28

EVAPORATOR AIRFLOW, CFM/DR


9600/0.160
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
279.62
302.64
327.32
268.1
221.12
173.8
30.17
30.82
31.35
270.57
293.21
317.09
257.44
218.43
170.98
33.12
33.78
34.32
254.75
276.35
298.76
249.65
215.75
168.13
35.08
35.78
36.37
241.36
261.78
283.86
234.16
208.9
162.14
37.6
38.35
38.98
221.77
241.05
261.56
219.55
203.34
156.62
39.41
40.21
40.87

11200/0.180
62
285.5
271.65
32.33
276.46
263.04
35.25
260.11
254.91
37.22
246.45
239.1
39.71
226.69
224.42
41.53

67
309.56
236.69
32.93
299.56
233.87
35.87
282.1
231.1
37.87
267.54
224.46
40.43
246.01
218.67
42.28

72
334.64
183.57
33.46
324.2
180.87
36.41
305.59
178.14
38.45
290.14
172.01
41.07
267.3
166.51
42.96

Model No.: PT360


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

9600/0.090
62
301.59
284.01
31.6
295.14
266.77
33.4
286.72
275.48
35.0
279.27
262.84
37.14
271.48
252.75
38.8

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
327.51
233.45
32.05
320.65
226.14
33.88
312.02
235.86
35.51
304.33
227.13
37.7
295.91
220.42
39.39

72
355.45
182.42
32.62
348.21
176.28
34.52
339.34
183.69
36.2
331.0
176.49
38.44
321.93
170.89
40.19

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


11250/0.10
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
309
336.07
365.1
285.18
254.19
195.66
33.04
33.49
34.17
302.44
329.03
357.62
278.95
246.51
189.26
34.86
35.35
36.09
294
320.37
348.7
282.47
257.48
197.48
36.46
36.98
37.78
286.16
312.3
339.9
274.83
247.99
189.76
38.65
39.22
40.08
278.43
303.36
330.71
264.51
240.64
183.97
40.32
40.93
41.83
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

12500/0.110
62
313.6
289.43
34.24
306.87
277.37
36.06
298.33
286.63
37.68
290.46
273.38
39.89
282.14
262.67
41.58

67
341.6
269.61
34.71
334.34
261.56
36.58
325.01
272.92
38.23
316.9
263.05
40.5
307.8
255.38
42.22

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.35 ESP.

12

72
371.26
205.43
35.45
363.5
198.77
37.38
353.92
207.22
39.09
345.55
199.54
41.42
336.21
193.56
43.21

ELECTRICAL DATA
MODELS: PT036 - PT060
POWER
SUPPLY
(V-Ph-Hz)

MODEL
NUMBER

VOLTAGE
RANGE
MIN.

380/415-3-50
(4 WIRE)

PT036

380/415-3-50
(4 WIRE)

PT048

342

342

MAX.

457

457

FM

FLA

2.3

2.3

COMPRESSOR

BLOWER
MOTOR

RLA

HP

LRA

5.9

42

10.4

FLA

0.75

55

5.5

0.75

5.5

380/415-3-50
(4 WIRE)

342

457

2.3

9.6

65

7.8

MCA

MOCP

kW

FLA

15.2

20

5/6

7.6/9.1

16.4/18.3

20/20

7.5/10* 11.4/15.2 21.1/25.9

25/30

12*

18.2

29.6

30

20.8

30

5/6

7.6/9.1

20.8/20.8

30/30

7.5/10* 11.4/15.2 21.1/25.9

35/30

12*

PT060

LEGEND:

ELECTRIC
HEATER

18.2

29.6

30

22.1

30

5/6

7.6/9.1

22.1/22.1

30/30

24/28.8

30/30

32.5

35

7.5/10* 11.4/15.2
12*

18.2

FLA

- Full Load Amps

HP

- Horse Power

BM

- Blower Motor

LRA

- Locked Rotor Amps

RLA

- Rated Load Amps

MCA

- Minimum Circuit Amps

MOCP - Maximum Over Current Protection


FM

- Fan Motor (Condenser)

*Combination of heater

modules

MODELS: PT075 & PT090


MODEL NUMBER

DESCRIPTION

PT075

VOLTAGE
RANGE

POWER
SUPPLY
(V-Ph-Hz)

Min.

Max.

FM
(each)
FLA

COMPRESSOR
(each)

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

5/6

*
12*/15*
7.5/10

380/415-3-50 (4 WIRE)

342

457

2.3
(1.9 FOR
PT090)

12

101

3.6

MCA

MOCP

20.7

30

FLA

1.5 3.4

PT090

7.6/9.1

20.7/20.7

30/30

11.4/15.2

20.7/23.3

30/30

18.2/22.8

27/32.8

30/35

20.9

30

5/6

7.6/9.1

20.9/20.9

30/30

*
12*/15*

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

7.5/10

COMPRESSOR
(each)

11.4/15.2

20.9/23.5

30/30

18.2/22.8

27.3/33

30/35

8.2

3.6

50

FLA

24

30

5/6

7.6/9.1

24/24

30/30

*
* *
20*

7.5/10

11.4/15.2

24/24

30/30

12 /15

18.2/22.8

27.3/33

30/35

30.4

42.5

45

25.1

30

5/6
4.7

MOCP

MCA

*
12*/15*
20*
7.5/10

7.6/9.1

25.1/25.1

30/30

11.4/15.2

25.1/25.1

30/30

18.2/22.8

28.6/34.4

30/35

30.4

43.9

45

MCA

MOCP

MODELS: PT100 & PT120


MODEL NUMBER

DESCRIPTION
POWER
SUPPLY
(V-Ph-Hz)

PT100

VOLTAGE
RANGE
Min.

Max.

FM
(each)
FLA

COMPRESSOR
(each)

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

3.6

7.5/10

* *
15*/20*

10 /12

380/415-3-50 (4 WIRE)

342

457

1.9

10.4 55

4.7

PT120

7.5/10

* *
15*/20*

10 /12

MCA

MOCP

28.9

35

FLA

11.4/15.2

28.9/28.9

35/35

28.9/28.9

35/35

22.8/30.4

33/42.5

35/45

30

10

4.7

74

40

11.4/15.2

30/30

40/40

15.2/18.2

30/30

40/40

22.8/30.4

34.4/43.9

40/45

13

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

15.2/18.2

COMPRESSOR
(each)

9.2

FLA

29.1

35

7.5/10

11.4/15.2

29.1/29.1

35/35

10 /12

15.2/18.2

29.1/29.1

35/35

15 /20

22.8/30.4

34.4/43.9

35/45
60

* *
* *
25*

38

53.4

33.6

40

7.5/10

11.4/15.2

33.6/33.6

40/40

10 /12

15.2/18.2

33.6/34.3

40/40

15 /20

22.8/30.4

40/49.5

40/50

38

59

60

* *
* *
25*

ELECTRICAL DATA
MODELS: PT180 & PT215
MODEL NUMBER

DESCRIPTION

PT180

VOLTAGE
RANGE

POWER
SUPPLY
(V-Ph-Hz)

Min.

Max.

FM
(each)
FLA

COMPRESSOR
(each)

380/415-3-50 (4 WIRE)

342

457

1.9

ELECTRIC
HEATER

BM

RLA LRA HP FLA Nom. kW

9.2

17.3 111
&
&
16.4 95

7.5

PT215

13

MCA

MOCP

FLA

COMPRESSOR
(each)

ELECTRIC
HEATER

BM

RLA LRA HP FLA Nom. kW

MCA

MOCP

FLA

51

60

56.2

70

7.5/10

11.4/15.2

51/51

60/60

7.5/10

11.4/15.2

56.2/56.2

70/70

10 /12

15.2/18.2

51/51

60/60

10 /12

15.2/18.2

56.2/56.2

70/70

15 /20

22.8/30.4

51/51

60/60

15 /20

22.8/30.4

56.2/56.2

70/70
70/70

* *
* *
25* /30*

38/45.6

59/68.5

60/70

54.8

70

7.5/10

11.4/15.2

54.8/54.8

70/70

* *
* *
25* /30*

10 /12

15.2/18.2

54.8/54.8

70/70

15 /20

22.8/30.4

54.8/54.8

70/70

38/45.6

63.8/73.3

70/80

9.2

19.2 125

7.5

13

* *
* *
25*/30*

38/45.6

59/68.5

60

70

7.5/10

11.4/15.2

60/60

7070

* *
* *
25*/30*

10 /12

15.2/18.2

60/60

70/70

15 /20

22.8/30.4

60/60

70/70

38/45.6

63.8/73.3

70/80

MCA

MOCP

MODELS: PT240 & PT300


MODEL NUMBER

DESCRIPTION

PT240

VOLTAGE
RANGE

POWER
SUPPLY
(V-Ph-Hz)

Min.

Max.

FM
(each)
FLA

COMPRESSOR
(each)

380/415-3-50 (4 WIRE)

342

457

1.9

ELECTRIC
HEATER

BM

RLA LRA HP FLA Nom. kW

7.5

PT300

13

19.6 118

10 15.1

MCA

MOCP

60.9

80

7.5/10

11.4/15.2

60.9/60.9

80/80

10 /12

15.2/18.2

60.9/60.9

80/80

15 /20

22.8/30.4

60.9/60.9

80/80

38/45.6

63.8/73.3

80/80

63

80

7.5/10

11.4/15.2

63/63

80/80

10 /12

15.2/18.2

63/63

80/80

15 /20

22.8/30.4

63/63

80/80

38/45.6

66.4/75.9

80/80

* *
* *
25* /30*

ELECTRIC
HEATER

BM

RLA LRA HP FLA Nom. kW

FLA

* *
* *
25* /30*

COMPRESSOR
(each)

* *
15*/20*
25*/30*
35*/40*

10 /12
7.5

13

25.6 167

* *
15*/20*
25*/30*
35*/40*

10 /12
10 15.1

FLA

78.2

100

15.2/18.2

78.2/78.2

100/100

22.8/30.4

78.2/78.2

100/100

38/45.6

78.2/78.2

100/100

53.2/60.8

82.8/92.3

100/100

80.3

100

15.2/18.2

80.3/80.3

100/100

22.8/30.4

80.3/80.3

100/100

38/45.6

80.3/80.3 100/100

53.2/60.8

85.4/94.9

100/100

MODEL: PT360
MODEL NUMBER

DESCRIPTION

POWER
SUPPLY
(V-Ph-Hz)

VOLTAGE
RANGE
Min.

Max.

FM
(each)
FLA

COMPRESSOR
(each)

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

* *
15*/20*
25*/30*
35*/40*

10 /12
10 15.1

380/415-3-50 (4 WIRE)

342

LEGEND:

PT360

457

1.9

27.8 198

15

MCA

MOCP

FLA

85.3

110

15.2/18.2

85.3/85.3

110/110

22.8/30.4

85.3/85.3

110/110

38/45.6

85.3/85.3

110/110

53.2/60.8

85.4/94.9

110/110

92.8

10 /12

15.2/18.2

92.8/92.8

110/110

22.6 15 /20

22.8/30.4

92.8/92.8

110/110

38/45.6

92.8/92.8

110/110

* *
* *
25*/30*
35*/40*

53.2/60.8

14

FLA

- Full Load Amps

HP

- Horse Power

BM

- Blower Motor

LRA

- Locked Rotor Amps

RLA

- Rated Load Amps

MCA

- Minimum Circuit Amps

110

94.8/104.3 110/110

MOCP - Maximum Over Current Protection


FM

- Fan Motor (Condenser)

*Combination of heater

modules

FAN PERFORMANCE DATA


(DIRECT DRIVE MOTOR)
Model No.: PT036
EXTERNAL STATIC PRESSURE (inch wg.)

BLOWER MOTOR
SPEED
0.1

0.2

0.3

0.4

0.5

0.6

CFM

1400

1340

1300

1280

1265

1250

BHP

0.78

0.75

0.73

0.7

0.69

0.67

CFM

1280

1220

1200

1180

1160

1150

BHP

0.7

0.69

0.69

0.67

0.65

0.64

CFM

1150

1120

1100

1080

1040

1000

BHP

0.65

0.6

0.6

0.58

0.57

0.56

HIGH

MEDIUM

LOW

Model No.: PT048


EXTERNAL STATIC PRESSURE (inch wg.)

BLOWER MOTOR
SPEED
0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

CFM

1680

1620

1550

1500

1480

1440

1410

1380

1340

1300

BHP

1.0

0.96

0.95

0.9

0.87

0.86

0.84

0.82

0.81

0.78

CFM

1500

1405

1385

1360

1300

1280

1240

1190

1160

1140

BHP

0.82

0.81

0.8

0.79

0.77

0.75

0.74

0.72

0.7

0.68

CFM

1300

1250

1220

1180

1160

1140

1100

1040

1000

950

BHP

0.71

0.7

0.68

0.66

0.64

0.61

0.58

0.56

0.54

0.53

HIGH

MEDIUM

LOW

Model No.: PT060


EXTERNAL STATIC PRESSURE (inch wg.)

BLOWER MOTOR
SPEED
0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

CFM

2055

2000

1980

1950

1940

1910

1880

1850

1800

1770

BHP

1.52

1.48

1.4

1.36

1.32

1.28

1.28

1.25

1.25

1.21

CFM

1850

1800

1750

1730

1710

1690

1680

1650

1640

1610

BHP

1.48

1.45

1.41

1.39

1.35

1.31

1.26

1.2

1.18

1.15

CFM

1650

1600

1558

1550

1542

1534

1526

1517

1495

1475

BHP

1.29

1.24

1.22

1.20

1.17

1.14

1.11

1.10

1.09

1.04

HIGH

MEDIUM

LOW

NOTE: Values include losses for dry coil, 1" thick filters & unit casing.

15

FAN PERFORMANCE DATA


Model No.: PT075
External Static Pressure (inch wg.)

Airflow,
CFM (L/S)

0.2

0.4

RPM

BHP

1800 (849)

761*

2000 (944)

0.6

0.8

1.0

1.2

1.4

1.6

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

0.42*

865

0.51

940

0.64

1016

0.76

1084

0.91

1148

1.02

1236

1.06

1264

1.18

808*

0.51*

886

0.64

965

0.77

1044

0.88

1106

1.04

1169

1.17

1242

1.31

1296

1.39

2200 (1038)

849*

0.65*

916

0.76

990

0.89

1066

1.08

1134

1.18

1191

1.32

1254

1.51

1312*

1.52*

2400 (1133)

864

0.74

942

0.89

1020

1.02

1084

1.18

1151

1.32

1212

1.49

1266

1.62

1324*

1.68*

2600 (1227)

894

0.92

968

1.10

1041

1.21

1120

1.35

1174

1.52

1228

1.72

1275

1.76

1332*

1.79*

2800 (1321)

925

1.08

995

1.25

1072

1.40

1138

1.48

1188

1.65

1254

1.82

1282

1.86

3000 (1416)

958

1.21

1039

1.40

1096

1.59

1164

1.69

1192

1.76

3200 (1510)

991

1.40

1075

1.71

1121

1.76

1173

1.82

II

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 1.5 HP motor to be used for the unshaded portion.
3. Alt. 2 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PT090


Airflow,
CFM (L/S)
2400 (1133)
2600 (1227)
2800 (1321)
3000 (1416)
3200 (1510)
3400 (1605)
3600 (1699)
3800 (1793)

0.2
RPM BHP
620*
660
672
700
705
719
735
755

0.65*
0.71
0.76
0.84
0.96
1.10
1.29
1.45

0.4
RPM BHP
680
720
741
765
771
795
804
810

0.71
0.82
0.91
1.10
1.25
1.41
1.49
1.61

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP
752
785
801
821
834
842
854
875

0.85
0.98
1.14
1.32
1.44
1.57
1.71
1.82

815
835
849
875
890
899
910
915

0.96
1.15
1.38
1.51
1.62
1.84
1.98
2.05

865
884
895
915
928
945
957
970

1.10
1.38
1.54
1.63
1.79
1.94
2.08
2.21

930
945
960
976
985
1000
1010
1021

1.38
1.51
1.62
1.76
1.87
1.98
2.21
2.35

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

990
1005
1012
1022
1029
1037
1045
1052

1090
1100
1109
1115
1124
1133
1137

1.45
1.61
1.73
1.84
2.01
2.18
2.31
2.55

1054
1065
1072
1084
1090
1095
1101
1105

1.68
1.76
1.88
1.99
2.18
2.31
2.48
2.62

1.78
1.91
2.00
2.15
2.33
2.54
2.67

1150
1161
1168*
1179*
1184*
1190*

1.92
2.05
2.21*
2.42*
2.62*
2.83*

II

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 2 HP motor to be used for the unshaded portion.
3. Alt. 3 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PT100


Airflow,
CFM (L/S)

0.2
RPM BHP

0.4
RPM BHP

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP
1080
1095
1100
1105
1109
1115
1122

2700 (1274
2800 (1321)
3000 (1416)
3200 (1510)
3400 (1605
3600 (1699)
3800 (1793)

610*
633*
650
665
685
700
720

0.73*
0.79*
0.85
0.92
1.01
1.10
1.25

690
700
708
725
750
765
787

0.75
0.85
0.97
1.12
1.35
1.48
1.65

750
762
781
796
805
816
835

0.87
0.95
1.10
1.28
1.44
1.56
1.70

805
810
832
841
855
871
895

1.09
1.17
1.32
1.43
1.52
1.65
1.82

864
875
890
900
911
921
938

1.41
1.47
1.59
1.67
1.75
1.84
1.98

925
934
951
959
978
986
995

1.65
1.72
1.82
1.91
1.98
2.08
2.21

975
987
998
1008
1016
1024
1035

1.71
1.84
1.93
2.06
2.17
2.29
2.41

1022
1.31
1045
1056
1065
1074
1081

1.79
1.88
1.99
2.10
2.22
2.46
2.61

4000 (1888)

745

1.40

805

1.78

859

1.92

907

1.97

951

2.18

1005

2.38

1048

2.55

1089

2.72

4100(1935)

765

1.51

815

1.91

881

2.01

921

2.16

967

2.35

1020

2.49

1056

2.66

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 2 HP motor to be used for the unshaded portion.
3. Alt. 3 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

16

1.91
2.02
2.11
2.25
2.54
2.61
2.74

1120
1135
1145
1152
1161

II

2.10
2.18
2.49
2.61
2.71

FAN PERFORMANCE DATA


Model No.: PT120
Airflow,
CFM (L/S)

0.2
RPM BHP

0.4
RPM BHP

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP
1074
1098
1115
1128
1141

3200 (1510)
3400 (1605)
3600 (1699)
3800 (1793)
4000 (1888)
4200 (1982)
4400 (2076)

685*
715*
735*
745
765
780
800

0.80*
1.02*
1.16*
1.24
1.32
1.44
1.56

750
760
790
805
820
835
845

1.03
1.16
1.22
1.37
1.52
1.64
1.77

795
825
835
850
865
890
905

1.09
1.26
1.36
1.51
1.66
1.84
1.99

850
880
895
905
925
935
955

1.24
1.39
1.56
1.69
1.84
2.06
2.31

890
910
930
945
955
975
995

1.44
1.54
1.71
1.87
2.12
2.24
2.39

950
970
985
995
1010
1025
1035

1.56
1.79
1.92
2.12
2.32
2.46
2.62

1008
1024
1036
1044
1061
1079
1091

1.71
2.01
2.12
2.26
2.40
2.61
2.82

1049
1062
1085
1105
1114
1121
1134

4600 (2170)

825

1.85

870

1.98

915

2.14

970

2.49

1005

2.54

1050

2.79

1105

2.92

4800 (2265)

835

2.07

885

2.13

930

2.28

985

2.62

1020

2.79

1070

2.98

II

1.99
2.11
2.26
2.39
2.69
2.79
2.93

2.15
2.34
2.46
2.64
2.85

1105
1128
1143
1165

2.36
2.47
2.62
2.81

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 3 HP motor to be used.
3. Bordered regions indicate alternative drives I & II.

Model No.: PT180


Airflow,
CFM (L/S)
4800 (2265
5000 (2360
5200 (2454)
5400 (2548)
5600 (2643)
5800 (2737)
6000 (2832)
6200 (2926)
6400 (3020)
6600 (3115)
6800 (3209)
7000 (3303)
7200 (3398)

0.2
RPM BHP

0.4
RPM BHP

698*
714*
718*
742*
758*
795
802
822
840
861
874
890
905

755*
768
781
802
809
831
845
864
879
891
904
930
942

1.45*
1.58*
1.85*
2.01*
2.18*
2.40
2.60
2.75
3.10
3.20
3.35
3.60
4.10

1.72*
1.79
2.03
2.20
2.35
2.64
2.83
3.01
3.25
3.61
3.65
3.98
4.25

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
1.4
1.6
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

790
805
818
845
865
890
910
915
921
935
948
956
985

1.91
2.05
2.30
2.50
2.70
2.80
2.91
3.14
3.50
3.62
3.91
4.21
4.55

845
871
880
895
905
928
941
956
968
980
998
1011
1025

2.17
2.20
2.39
2.49
2.74
2.91
3.20
3.40
3.60
3.95
4.22
4.61
4.88

880
895
914
921
938
961
975
994
1011
1025
1041
1052
1065

2.19
2.40
2.65
2.84
3.00
3.21
3.45
3.60
3.80
4.10
4.34
4.68
5.28

930
940
955
981
995
1012
1025
1032
1048
1060
1071
1085
1098

2.50
2.74
2.98
3.22
3.35
3.60
3.81
3.90
4.12
4.35
4.85
5.24
5.58

971
985
995
1011
1030
1050
1061
1075
1092
1100
1110
1120
1135

1.8
RPM BHP

II

2.60 1020 2.91 1060


2.80 1031 3.05 1070
3.12 1039 3.28 1081
3.20 1055 3.50 1096
3.50 1068 3.75 1110
3.70 1080 4.00 1121
3.92 1096 4.19 1135
4.20 1112 4.48 1142*
4.50 1119 4.79 1157*
4.81 1127 4.98 1169*
5.40 1145* 5.60* 1178*
5.65 1158* 6.10* 1198*
5.95 1170* 6.21* 1210*

3.20
3.40
3.65
3.91
4.09
4.40
4.60
4.90*
5.21*
5.50*
6.10*
6.32*
6.66*

2.0
RPM BHP
1095
1110
1121
1135
1144*
1155*
1169*
1181*
1190*
1199*
1208*
1219*
1228*

3.55
3.74
4.01
4.19
4.39*
4.68*
4.91*
5.22*
5.55*
5.79*
6.35*
6.60*
7.05*

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 5 HP motor to be used for the unshaded portion.
3. Alt. 7.5 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PT215


Airflow,
CFM (L/S)
5800 (2737)
6000 (2832)
6200 (2926)
6400 (3020)
6600 (3115)
6800 (3209)
7000 (3303)
7200 (3398)
7400 (3492)
7600 (3587)
7800 (3681)
8000 (3775)
8200 (3870)

0.2
RPM BHP
601
617
630
647
662
689
705
720
734
755
786
798
808

1.98
2.08
2.20
2.45
2.86
3.02
3.24
3.65
3.84
4.02
4.31
4.64
4.84

0.4
RPM BHP
649
661
674
691
703
711
722
735
746
762
792
806
822

2.26
2.45
2.55
2.66
2.91
3.12
3.34
3.78
3.91
4.14
4.44
4.61
4.98

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
1.4
1.6
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

678
692
710
721
734
741
768
782
795
812
831
855
876

2.69
2.76
2.84
2.96
3.07
3.24
3.41
3.84
3.98
4.21
4.54
4.72
5.09

728
741
754
762
778
790
808
821
839
855
869
892
904

2.89
2.98
3.07
3.21
3.44
3.61
3.78
3.90
4.08
4.34
4.65
4.82
5.21

772
784
802
816
832
844
852
865
875
884
892
906
914

3.10
3.21
3.34
3.46
3.68
3.81
3.92
4.10
4.24
4.46
4.84
5.09
5.44

816
834
846
854
868
881
894
902
912
921
928
936
948

3.42
3.52
3.60
3.84
3.98
4.22
4.41
4.62
4.78
5.00.
5.40
5.61
5.82

853
866
880
891
904
912
920
929
938
946
954
963
970

3.62
3.75
4.10
4.21
4.34
4.52
4.71
4.95
5.14
5.34
5.50
5.64
5.85

886
898
910
921
930
939
950
959
968
979
991
999
1012

3.92
4.12
4.21
4.38
4.55
4.74
4.96
5.20
5.36
5.72
5.96
6.10
6.22

1.8
RPM BHP

2.0
RPM BHP

928
939
950
962
975
984
993*
1004*
1015*
1023*
1034*
1042*
1051*

964
978
990
997
1008*
1017*
1024*
1032*
1040*
1048*
1055*
1062*

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 5 HP motor to be used for the unshaded portion.
3. Alt. 7.5 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.
17

4.23
4.38
4.51
4.62
4.73
4.89
5.20*
5.48*
5.67*
5.98*
6.38*
6.60*
6.82*

4.72
4.81
4.90
5.14
5.32*
5.48*
5.62*
5.94*
6.32*
6.71*
7.20*
7.50*

II

FAN PERFORMANCE DATA


Model No.: PT240
Airflow,
CFM (L/S)
6000 (2832)
6200 (2926
6400 (3020)
6600 (3115)
6800 (3209)
7000 (3303)
7200 (3398)
7400 (3492)
7600 (3587)
7800 (3681)
8000 (3775)
8200 (3870)
8400 (3964)
8600 (4058)
8800 (4152)
9000 (4247)

0.2
RPM BHP

0.4
RPM BHP

600*
615*
625*
650*
665
678
689
700
712
732
748
767
778
799
812
828

640*
665*
684
698
709
717
730
748
762
783
791
805
810
825
840
865

2.15*
2.30*
2.51*
2.82*
2.98
3.22
3.45
3.64
3.84
4.10
4.45
4.80
5.10
5.40
5.59
5.82

2.40*
2.65*
2.95
3.10
3.28
3.45
3.62
3.89
4.21
4.62
4.89
5.01
5.35
5.64
6.12
6.35

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP
700
710
718
735
745
758
767
778
792
805
818
835
850
865
882
895

2.82
2.95
3.15
3.40
3.58
3.69
4.01
4.35
4.61
4.85
5.10
5.51
5.72
5.95
6.21
6.48

730
745
760
778
792
800
810
822
839
852
861
874
891
900
909
924

2.95
3.15
3.30
3.52
3.84
4.05
4.21
4.44
4.72
5.10
5.46
5.73
6.02
6.31
6.64
6.97

780
790
800
808
815
820
835
854
868
884
895
905
915
927
940
970

3.20
3.40
3.57
3.79
3.92
4.15
4.48
4.89
5.25
5.52
5.91
6.22
6.48
6.90
7.20
7.40

815
825
833
840
851
865
880
892
905
915
922
934
946
960
974
990

3.65
3.81
4.04
4.25
4.48
4.72
5.01
5.34
5.56
5.84
6.10
6.40
6.70
7.10
7.30
7.70

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

850
859
862
874
891
908
916
925
934
948
960
971
984
996
1008
1118

920
918
928
935
948
958
969
978
988
999*
1010*
1017*
1023*
1029*

3.91 900
4.50
4.30 912
4.91
4.69 919
5.25
4.95 926
5.48
5.32 933
5.82
5.51 940
6.10
5.80 947
6.38
6.12 958
6.52
6.28 970
6.68
6.41 981
6.74
6.50 990
6.94
6.82 997
7.31
7.10 1010* 7.52*
7.40 1018* 7.89*
7.64 1024* 8.20*
7.92

4.98
5.28
5.46
5.81
6.21
6.42
6.67
6.94
7.18
7.37*
7.51*
7.85*
8.11*
8.38*

970
979
994
1008*
1019*
1028*
1040*
1052*
1059*
1066*
1074*
1079*

5.30
5.52
5.86
6.24*
6.56*
6.84*
7.10*
7.40*
7.73*
8.10*
8.31*
8.52*

II

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 7.5 HP motor to be used for the unshaded portion.
3. Alt. 10 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PT300


Airflow,
CFM (L/S)
8000 (3775
8200 (3870)
8400 (3964)
8600 (4058)
8800 (4152)
9000 (4247)
9200 (4341)
9400 (4436)
9600 (4530)
9800 (4624)
10000 (4719)
10200 (4813)
10400 (4907)
10600 (5002)
10800 (5096)
11000 (5191)
11200 (5286)

0.2
RPM BHP

0.4
RPM BHP

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP

641*
650*
664*
679*
696*
714*
729*
746
765
779
791
802
812
821
833
841
849

695*
710*
726*
735*
744
756
764
779
789
799
812
824
839
851
867
880
891

735*
748
765
777
784
790
801
821
834
848
860
871
882
895
902
910
917

3.24*
3.40*
3.51*
3.65*
3.78*
4.10*
4.32*
4.56
4.78
4.97
5.20
5.47
5.83
5.95
6.10
6.30
6.49

3.63*
3.85*
4.13*
4.28*
4.44
4.59
4.72
4.88
5.10
5.33
5.51
5.74
5.95
6.32
6.64
6.95
7.29

3.84*
4.10
4.32
4.47
4.64
4.91
5.20
5.49
5.72
5.97
6.22
6.41
6.66
6.95
7.29
7.52
7.89

764
781
804
821
832
841
852
865
878
887
895
904
912
918
925
934
941

4.18
4.36
4.48
4.62
4.85
5.13
5.28
5.51
5.84
5.95
6.31
6.54
6.78
6.96
7.34
7.69
7.98

795
814
831
848
862
875
888
897
906
913
921
928
934
941
949
951
955

4.48
4.70
4.81
4.95
5.12
5.48
5.75
5.95
6.32
6.62
6.95
7.24
7.39
7.64
7.95
8.21
8.61

839
862
874
888
900
911
919
928
936
944
952
959
966
972
978
984
991

4.85
5.21
5.36
5.49
5.78
5.94
6.21
6.39
6.61
6.88
7.14
7.39
7.62
7.88
8.03
8.36
8.68

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

865
895
921
928
937
948
958
966
978
989
996
1004
1009
1014
1021
1028

942
965
977
989
1000
1010
1016
1024
1031
1036
1044
1051
1056

5.10
5.42
5.63
5.89
6.24
6.63
6.85
7.12
7.20
7.38
7.76
7.91
8.13
8.38
8.76
9.05

905
939
955
967
975
984
991
998
1008
1015
1022
1029
1038
1045
1051

5.55
5.69
5.87
5.99
6.41
6.73
7.10
7.24
7.44
7.66
7.92
8.18
8.41
8.72
9.10

II

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 7.5 HP motor to be used for the unshaded portion.
3. Alt. 10 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

18

5.91 992
6.30
6.18 1015 6.55
6.32 1026 6.78
6.52 1034 6.92
6.79 1046 7.14
7.05 1055 7.34
7.29 1065 7.55
7.62 1076 7.71
7.88 1084 7.96
8.18 1096* 8.28*
8.39 1105* 8.52*
8.79 1112* 9.10*
9.10

FAN PERFORMANCE DATA


Model No.: PT360
Airflow,
CFM (L/S)
9600 (4530)
9800 (4624)
10000 (4719)
10200 (4813)
10400 (4907)
10600 (5002)
10800 (5096)
11000 (5191)
11200 (5286)
11400 (5380)
11600 (5474)
11800 (5569)
12000 (5663)
12200 (5757)
12400 (5852)
12500 (5899)

0.2
RPM BHP
745
757
770
778
785
793
802
810
829
851
868
885
900
911
919
930

5.61
5.72
5.84
6.10
6.29
6.64
6.92
7.30
7.51
7.77
7.99
8.22
8.54
8.92
9.42
9.86

0.4
RPM BHP
765
777
794
814
835
849
864
878
888
897
905
914
925
938
949
960

5.95
6.11
6.20
6.36
6.58
6.79
7.10
7.46
7.77
8.08
8.42
8.74
9.20
9.65
10.10
10.70

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP
792
806
820
834
846
861
875
890
902
918
929
938
951
962
977
985

6.32 819
6.51 836
6.70 855
6.95 866
7.30 878
7.62 891
8.10 904
8.41 918
8.78 931
9.10 946
9.38 957
9.65 968
9.98 977
10.40 988
10.72 1000
11.30 1010

6.87
6.99
7.10
7.34
7.61
7.98
8.42
8.88
9.21
9.64
9.94
10.32
10.76
11.10
11.61
12.20

852
867
895
908
921
942
955
965
974
983
992
1004
1015
1024
1032
1040

7.35
7.52
7.70
7.86
8.11
8.42
8.78
9.14
9.48
9.82
10.18
10.62
10.98
11.44
11.87
12.60

879
7.72
894
7.94
915
8.10
927
8.41
939
8.78
951
9.10
966
9.54
985
9.92
998 10.22
1011 10.51
1021 10.94
1032 11.21
1042 11.58
1051 11.84
1059 12.45

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

911
936
955
976
994
1000
1008
1015
1023
1041
1057
1061
1080

981
998
1018
1027
1039
1048
1061
1070
1081
1092*
1102*

8.19
8.34
8.52
8.79
9.12
9.45
9.72
10.10
10.41
10.73
11.18
11.62
12.16

952
976
995
1015
1029
1040
1049
1058
1067
1076
1084
1092*

8.61
8.82
9.00
9.24
9.56
9.77
10.10
10.68
10.99
11.40
11.92
12.34*

II

Notes: 1. Values include losses for filters, unit casing and wet coils.
2. Standard 10 HP motor to be used for the unshaded portion.
3. Alt. 15 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

19

8.92
9.18
9.30
9.45
9.68
9.96
10.38
10.84
11.25
11.64*
12.25*

1010
1028
1046
1064
1073
1084
1091*
1100*
1111*
1121*

9.30
9.42
9.80
10.34
10.76
11.10
11.84*
12.32*
12.67*
12.98*

SOUND LEVEL DATA


To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP (see step 4 & table below).
2. Read dBA level from respective graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from sound power factor table and add dBA level to each values in the row to obtain
Sound Power Level (dB re 10-12 watts).
4. Calculate TSP (Total Static Pressure) as follows:
TSP = ISP + ESP
ESP (External Static Pressure) from Job Specification.
ISP (Internal Static Pressure) Calculate from table below.
FACE VELOCITY

INTERNAL STATIC PRESSURE (inch wg.)

(FPM)
2 ROW

3 ROW

4 ROW

200

0.42

0.44

0.47

300

0.67

0.73

0.78

400

0.88

0.95

1.05

450

1.02

1.13

1.23

500

1.16

1.29

1.49

NOTE:
Pressure drop across filter, coil and casing are included in ISP.

20

SOUND LEVEL DATA


MODELS: PT036 - PT060

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

493-887 RPM

7.5

+ 0.5

+ 7.5

+ 10.5

+ 5.5

+2

6.5

887-1750 RPM

+ 0.5

+7

+7

+8

+ 1.5

1.5

6.5

1750-2500 RPM

+ 0.5

+7

+7

+5

+ 4.5

1.5

6.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).

21

SOUND LEVEL DATA


MODEL: PT075

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

251-495 RPM

+2

+ 11.5

+8

+ 5.5

+2

6.5

495-990 RPM

6.5

+ 1.5

+8

+ 10.5

+5

+ 1.5

1.5

990-1953 RPM

+ 1.5

+8

+7

+8

+ 1.5

7.5

1953-2050 RPM

+ 1.5

+8

+7

+5

+ 4.5

7.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
22

SOUND LEVEL DATA


MODELS: PT090 - PT180

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

211-417 RPM

4.5

+3

+ 12

+8

+5

+2

1.5

417-835 RPM

5.5

+ 2.5

+ 8.5

+ 10.5

+ 4.5

+ 1.5

7.5

835-1647 RPM

5.5

+ 2.5

+8

+7

+7

+1

2.5

7.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
23

SOUND LEVEL DATA


MODELS: PT215 - PT360

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

255-443 RPM

3.5

+4

+ 12.5

+8

+ 4.5

+ 1.5

7.5

443-887 RPM

+ 3.5

+9

+ 10

+4

+1

2.5

887-1750 RPM

+ 3.5

+ 8.5

+7

+7

+ 0.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
24

STATIC PRESSURE DROP (inch wg.)


MODELS: PT036 - PT060
CFM

COMPONENT

900
0.12
0.19

1 HEATER MODULE
2 HEATER MODULE

1200
0.12
0.19

1400
0.12
0.19

1600
0.13
0.20

1800
0.14
0.21

2000
0.15
0.21

MODELS: PT075
COMPONENT
1 HEATER MODULE
2 HEATER MODULE

CFM
1600
0.11
0.18

1800
0.12
0.19

2000
0.13
0.19

2200
0.13
0.19

2400
0.14
0.20

2600
0.15
0.21

3000
0.16
0.21

3200
0.16
0.21

3400
0.17
0.22

3600
0.18
0.23

3800
0.18
0.23

3600
0.09
0.11

3800
0.10
0.12

4000
0.11
0.14

4400
0.13
0.16

4800
0.14
0.18

7400
0.10
0.16

7800
0.11
0.17

8200
0.11
0.17

8600
0.12
0.18

9000
0.13
0.18

MODELS: PT090 - PT120


COMPONENT
1 HEATER MODULE
2 HEATER MODULE

CFM
2400
0.04
0.05

2600
0.04
0.06

2800
0.04
0.06

3000
0.05
0.07

3200
0.07
0.09

3400
0.08
0.10

MODELS: PT180 - PT240


COMPONENT
1 HEATER MODULE
2 HEATER MODULE

CFM
4800
0.08
0.14

5200
0.08
0.14

5600
0.08
0.14

6200
0.08
0.14

6600
0.09
0.15

7000
0.10
0.16

MODELS: PT300 - PT360


COMPONENT
1 HEATER MODULE
2 HEATER MODULE

CFM
8000
0.09
0.16

8400
0.09
0.16

8800
0.10
0.17

9200
0.10
0.18

9600 10000 10400 10800 11200 11600 12000 12500


0.11 0.12 0.12 0.13 0.13 0.14 0.15 0.16
0.18 0.19 0.19 0.20 0.21 0.22 0.23 0.24

BLOWER MOTOR EFFICIENCY


MOTOR HP

0.75

1.0

1.5

2.0

3.0

5.0

7.5

10.0

EFFICIENCY (%)

0.81

0.81

0.80

0.81

0.81

0.80

0.81

0.80

NOTE: Convert BHP to watts using following formula


746 x BHP
Watts =
Motor Efficiency

25

UNIT DIMENSIONS

AIR IN

PT036 - PT075

COMPRESSOR/CONTROL
COMPARTMENT

POWER SUPPLY INLET

AIR IN
CONDENSER COIL

CONDENSATE DRAIN OUTLET [BOTH ENDS]

TOP VIEW

SUPPLY
AIR
OPENING

FILTER ACCESS
PANEL [BOTH ENDS]

SUPPLY AIR

ACCESS PANEL
FOR BLOWER
AND MOTOR

CONDENSER COIL

RETURN AIR
OPENING

FRESH AIR
OPENING

COMPRESSOR/CONTROLS
ACCESS PANEL

DRAIN OUTLET
[BOTH ENDS]

51 [2.00]

15 [0.59]
61 [2.41]

286 [11.27]

SIDE VIEW

90 [3.53]

RETURN AIR

FRONT VIEW

SIDE VIEW

DIMENSIONS
MODEL
A

PT036 - PT060

1460(57.48)

PT075

1775(69.88)

1025(40.35)

1430(56.3)

700(27.56)

163(6.42) 373(14.68) 250(9.84) 500(19.69) 57(2.24) 304(11.96) 343(13.49) 340(13.39)

1150(45.28)

1745(68.7)

800(31.5)

175(6.89) 480(18.9) 325(12.8) 672(26.46) 80(3.15) 280(11.02) 275(10.83) 600(23.62)

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).
2. Service clearance should be 1200mm (4 feet) on all sides.

26

850 [33.46]

AIR OUT

MOUNTING HOLES
13 [0.5] [ 4 EACH]

UNIT DIMENSIONS
PT090 - PT120

TOP VIEW

SIDE VIEW

FRONT VIEW

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).
2. Service clearance should be 1200mm (4 feet) on all sides.

27

SIDE VIEW

UNIT DIMENSIONS
PT180

TOP VIEW

SIDE VIEW

FRONT VIEW

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).
2. Service clearance should be 1200mm (4 feet) on all sides.

28

SIDE VIEW

UNIT DIMENSIONS
PT215 - PT240

TOP VIEW

SIDE VIEW

FRONT VIEW

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).
2. Service clearance should be 1200mm (4 feet) on all sides.

29

SIDE VIEW

UNIT DIMENSIONS
PT300 - PT360

TOP VIEW

SIDE VIEW

FRONT VIEW

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).
2. Service clearance should be 1200mm (4 feet) on all sides.

30

SIDE VIEW

Performex-1TM CONTROLLER: OPERATION & FUNCTIONS

LCD display: a) Room temperature display


b) Mode of operation (Cool/Heat/Auto/Fan system control)
c) Set temperature
d) Compressor Status - ON/OFF/FAULT
e) Error Codes
1. ON/OFF: Press the ON/OFF button & the unit shall be switched ON. A status Led adjacent to this button shall light up
indicating the unit is switched ON. To shut off the unit, press this button again.
2. MODE: Press the mode button to select the desired mode. On selection the corresponding icon shall be displayed on
the LCD display panel.
3. TEMPERATURE RANGE AND SETTING: The operating temperature range is 160C to 300C (610F to 860F), both
inclusive. Press the UP or DN button to select the desired temperature. The temperature setting is effective only for
the Cool, Heat and Auto modes.
4. INDOOR (EVAPORATOR) FAN: There is one indoor fan with single fan speed. When fan speed on LCD panel is
HIGH, indoor fan will always turns on. Indoor fan can be set off, when the compressor is cut off by setting the fan
speed to AUTO on the LCD panel by pressing Fan button. By pressing the Fan button again the fan speed can resume
to HIGH.
5. COOL MODE: Whenever the unit is started in cool mode (without Pump Down Solenoid-PDS), the compressors will
be turned on one by one depending on the load requirement of the unit.
6. HEAT MODE (HEATER MODEL): Whenever the unit is started in heat mode, the heaters shall be switched ON one
by one to meet the load requirement.
31

7. LEAD/LAG OPERATION: Whenever a compressor needs to be on, the controller will turn on the compressor with the
shorter accumulated run time provided its 3 minutes minimum off time has lapsed. Otherwise the other compressor
will on first. Similarly, the compressor with the longer accumulated run time will be the first one to be cut off. This is to
load the compressors evenly over long run period. Balance loading is enabled when compressor #1 lead option is
disabled.
8. AUTO MODE: In Auto mode, operating mode will be selected automatically between Heat and Cool mode, depending
on the Room Temperature and Set Temperature.

PROTECTION
The following safeties are provided for the system:
1. Compressor high pressure protection (option)
2. Compressor low pressure protection

TYPICAL HIGH AND LOW VOLTAGE FIELD WIRING CONNECTIONS


L1

L2

L3

N (FOR 380V ONLY)

FUSED DISCONNECT SWITCH


OR CIRCUIT BREAKER
PACKAGE UNIT
CONTROL PANEL

HVTB

L1
LEGEND

L2

ECB - ELECTRONIC CONTROL BOARD


HVTB - HIGH VOLTAGE TERMINAL BLOCK
LI - LINE1
L2 - LINE2
L3 - LINE3

NTB

L3
N
G

N - NEUTRAL TERMINAL BLOCK


G - GROUND

+5V
B
A

ECB

GND

FIELD WIRING

CONTROL WIRES-INTERCONNECTING
( USE 16 TO 22 AWG WIRE)

+5V GND

INDOOR THERMOSTAT

32

TYPICAL SCHEMATIC WIRING DIAGRAM

NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items.
2. Refer to unit control box (inside panel) for exact wiring diagram.

33

TYPICAL SCHEMATIC WIRING DIAGRAM


LEGEND
AR
AFS
ATB
BM
BMC
CC
CCA
CB
C. HTR
COMP
ECB
FCS
F
FL
FM
FMC
FR
HC
HPS
HVTB
HTR

AUXILIARY RELAY
AIRFLOW SWITCH
AUXILIARY TERMINAL BLOCK
BLOWER MOTOR
BLOWER MOTOR CONTACTOR
COMPRESSOR CONTACTOR
AUXILIARY CONTACT
CIRCUIT BREAKER
CRANKCASE HEATER
COMPRESSOR
ELECTRONIC CONTROL BOARD
FAN CYCLING SWITCH
FUSE
FUSE LINK
FAN MOTOR (CONDENSER)
FAN MOTOR CONTACTOR
FAULT RELAY
HEATER CONTACTOR
HIGH PRESSURE SWITCH
HIGH VOLTAGE TERMINAL BLOCK
HEATER

JP
L1
L2
L3
LPS
LUG
NTB
O/L
OHT
PDS

JUMPER
LINE 1
LINE 2
LINE 3
LOW PRESSURE SWITCH
LUG GROUND
NEUTRAL TERMINAL BLOCK
OVER LOAD
OVER HEAT THERMOSTAT
PUMP DOWN SOLENOID

SSPS

SOLID STATE PROTECTIVE SYSTEM

SD

SMOKE DETECTOR

TRANS TRANSFORMER
T'STAT

THERMOSTAT

UVM

UNDER VOLTAGE MONITOR

___
+

FIELD WIRING
DISCONNECT TAB - 1/4"
SPLICE-CLOSED END
TERMINAL BLOCK OR TERMINATION POINT

NOTES
1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.
2. ANY WIRE REPLACEMENT SHOULD BE OF 900C OR ITS
EQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY.
3. IF PDS & HEATERS ARE FACTORY INSTALLED, PLEASE
READ BROKEN LINES AS CONTINUOUS LINES.
4. POWER MUST BE SUPPLIED TO CRANKCASE HEATER
FOR MINIMUM OF 12 HOURS PRIOR TO SYSTEM START
UP.
IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE
HEATER MUST BE ON FOR 12 HOURS BEFORE OPERATING THE SYSTEM.
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN COMPRESSOR DAMAGE.
5. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER
TO BE PROVIDED BY CONSUMER WITH RATING AS
RECOMMENDED BY COOLINE.
6. COMPRESSORS ARE PROVIDED WITH INTERNAL OVERLOAD.
7. IF COMPRESSOR IS SUPPLIED WITH SSPS, CONNECT AS
SHOWN. PLEASE ALLOW 2-3 MINUTES FOR SSPS SWITCH
TO CLOSE, BEFORE STARTING THE UNIT.
8. IF ANY CHANGE IN DIP SWITCH SETTING IS REQUIRED,
TURN OFF POWER FIRST & SET REQUIRED SETTING.

34

PARTS LIST
MODEL NUMBER

PT036L PT048L PT060L PT075L

PT090 PT100L PT120L PT180L PT215L

COMPRESSOR

800-684-08 800-672-52 800-643-01 800-674-78 800-684-09 800-672-52 800-674-25 800-674-67/81 800-674-38

FAN MOTOR

800-555-26 800-555-26 800-555-26 800-555-26 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68

FAN MOTOR CAPACITOR

800-353-15 800-353-15 800-353-15 800-353-15

BlOWER MOTOR (STANDARD)

800-546-94 800-546-94 800-546-95 800-544-13 800-544-16 800-544-16 800-544-17 800-544-72 800-544-72

BLOWER WHEEL

800-707-10 800-707-10 800-707-10 800-707-46 800-707-02 800-707-02 800-707-02 800-707-02 800-707-23

CONDENSER FAN PROPELLER

800-225-02 800-225-02 800-225-02 800-225-02 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23

COMPRESSOR CONTACTOR

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-736-22

BL0WER MOTOR CONTACTOR

800-736-27 800-736-27 800-736-27 800-095-01 800-095-01 800-095-01 800-095-01 800-098-55 800-098-55

AIRFLOW SWITCH

800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE

800-195-16 800-195-20 800-195-22 800-181-00 800-183-01 800-181-00 800-181-00 800-182-00 800-182-00

DISTRIBUTOR

800-194-13 800-194-13 800-194-17 800-191-01 800-191-00 800-191-00 800-191-00 800-196-00 800-194-01

LOW PRESSURE SWITCH

800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

N.A.

N.A.

N.A.

N.A.

N.A.

HIGH PRESSURE SWITCH (OPTION) 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00
FAN GRILLE

800-625-46 800-625-46 800-625-46 800-625-46 800-625-29 800-625-29 800-625-29 800-625-74 800-625-74

FILTER DRIER

800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-05 800-531-05

SIGHT GLASS (OPTION)

800-201-00 800-201-00 800-201-00 800-201-00 800-201-00 800-201-00 800-200-00 800-200-00 800-200-00

MODEL NUMBER

PT240L PT300L PT360L

COMPRESSOR

800-674-19 800-674-12 800-674-72

FAN MOTOR

800-545-68 800-545-68 800-545-68

BlOWER MOTOR (STANDARD)

800-544-73 800-544-73 800-544-74

BLOWER WHEEL

800-707-23 800-707-23 800-707-23

CONDENSER FAN PROPELLER

800-224-23 800-225-02 800-225-02

COMPRESSOR CONTACTOR

800-736-22 800-736-22 800-736-22

BL0WER MOTOR CONTACTOR

800-098-55 800-098-55 800-098-57

AIRFLOW SWITCH

800-005-02 800-005-02 800-005-02

EXPANSION VALVE

800-185-00 800-186-00 800-186-00

DISTRIBUTOR

800-194-01 800-196-10 800-191-34

LOW PRESSURE SWITCH

800-557-00 800-557-00 800-557-00

HIGH PRESSURE SWITCH (OPTION) 800-558-00 800-558-00 800-558-00


FAN GRILLE

800-625-74 800-625-46 800-625-46

FILTER DRIER

800-531-05 800-531-05 800-531-01

SIGHT GLASS (OPTION)

800-200-00 800-200-00 800-200-01

OPTIONAL ITEMS:
ANTI ICE THERMOSTAT : 800-644-22 (COMMON TO ALL MODELS)
RETURN AIR FILTERS
Aluminum filter (1 Thick) : 800-254-10 (2 Each) for PT036 - PT060, 800-254-11 (2 Each) for PT075, 800-254-12 (2 Each) for PT090 - PT120,
800-254-13 (2 Each) for PT180, 800-254-14 (4 Each) for PT215 - PT240 & 800-254-15 (4 Each) for PT300 - PT360.
Aluminum filter (2 Thick) : 800-254-16 (2 Each) for PT036 - PT060, 800-254-17 (2 Each) for PT075, 800-254-18 (2 Each) for PT090 - PT120,
800-254-19 (2 Each) for PT180, 800-254-20 (4 Each) for PT215 - PT240 & 800-254-21 (4 Each) for PT300 - PT360.

35

Você também pode gostar