Você está na página 1de 68

Table of Contents

Fuse Holder Selection Chart Surface Mount Fuses Axial and Radial Leaded Fuses 5 x 15mm Fuses 5 x 20mm Fuses 6.3 x 32mm Fuses Automotive Fuses Miscellaneous Fuses Fuse Clips for 5mm dia. Fuses Fuse Clips for 6.3mm dia. Fuses Fuse Clips Miscellaneous Sizes Fuse Clips Automotive Fuse Holders Fuse Holders In-Line Fuse Holders In-Line Automotive Fuse Blocks Fuse Technology and Glossary of Terms Parts Index 2 3 8 12 18 36 46 47 51 53 55 56 57 63 64 65 67 68

Bussmann

Useful Telephone Numbers UK Sales Export Sales Application Engineers Phone: Fax: Phone: Fax: Phone: Fax: Catalogue Requests Phone: Fax: e-mail: 01509 882606 01509 882788 +44 1509 882700 +44 1509 882789 +44 (0)1509 882766 +44 (0)1509 882760 +44 (0)1509 882786 +44 (0)1509 882715 +44 (0)1509 882794 micht@bussmann.co.uk

Sales on e-mail: World Wide Web Site

sales@bussmann.co.uk www.bussmann.com

Our World Wide Web site has information on all Bussmann products, together with catalogues and Data Sheets and useful application information.

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

Fuse Holder Selection Chart

Bussmann

P a n el Mo u n t F u se Ty pe an d Holders S ize S crewdriver S lot Carrier 5 x 20mm S500 to S508 GDA, GDB and GDC GMA, GMC and GMD C640 and C641 HTB3*M HTB5*M HTB9*M HTC35M HTC40M HTC55M HTC70M

P a n el Mo u n t Holders F in gergrip S crew or Bay on et Carrier

P C Board Holders en closed

P C Board Holders o p en

F u se Blocks

In -lin e F u se Holders

F u se Clips

HTB2*M Series HTB4*M Series HTB6*M Series

HBV-M HBW-M HBH-M

HTC15M HTC15MS

HTC10M

HTC200M HTC210M HTC220M 1A3399 1A5108 1A5601 1A5602

5 x 15mm C519 C520

HTC200M HTC210M HTC220M 1A3399 1A5108 1A5601 1A5602

6.3 x 32mm TDC10 TDA304 TDC455 ABC AGC MDQ GBB TDC11 TDC436 TDC459 MDL MDA HTB2*I HTB4*I HTB6*I HTB8*I HKP Series HK L HM R 1A3398 1A4533 1A1907 1A4534 1A1119 1A1120 5681 5682

HTB3*I HTB5*I HTB9*I

HBV-I HBW-I HBH-I

S8000 Series 2499 4574 4405 4406

HFB HHB HFA

6.3 x 32mm GBA and GLD

S8000 Series HLD 2499 4574 4405 4406

1A3398 1A4533 1A1907 1A4534 1A1119 1A1120 5681 5682 1A3398 1A4533 1A1907 1A4534 1A1119 1A1120 5681 5682

6.3 x 25.4mm AGX TDC180

HJL HJM HM S

4520 4393 3828

HHB HRK

Application Engineers +44 (0)1509 882766 or 882760

Surface Mount Fuses

Bussmann

1608FF
Agency Approvals: General Description: Bussmann SMT Chip Fuses utilise thick and thin metal film technologies for superior fusing action and enhanced reliability. The fuse element is bonded to a ceramic substrate and encapsulated with glass, providing excellent short circuit performance and environmental integrity. Predicted reliability of the 1608FF chip fuse is 30 times greater than that of the typical chip capacitor (consult Bussmann for details). Substrate and coating thermal expansion coefficients are closely matched to that of FR-4 epoxy glass circuit board for superior solder joint reliability. The end terminations are over-plated with nickel and tin base. Breaking Capacity: 100% rated current: 250% rated current: Dimensions (mm): 35 A @ rated voltage 4 hours minimum carry. open within 5 seconds. Time Current Characteristics:
v

Order Code: Packing Code + 1608FF + Rating Type: Rated Voltage: Very Fast Acting Ratings (A): 250mA to 4A 24V dc

Packing Code Prefix:

TR = 3,000 pieces on 8mm tape on a 178mm reel TR1 = 15,000 pieces on 8mm tape on a 330mm reel SP = 50 pieces on tape in a plastic box

Performance Data
P art Nu mber xx = P ackin g Co de xx/1608F F -250mA xx/1608F F -375mA xx/1608F F -500mA xx/1608F F -750mA xx/1608F F -1A xx/1608F F -1. 5A xx/1608F F -2A xx/1608F F -2. 5A xx/1608F F -3A xx/1608F F -3. 5A xx/1608F F -4A Cu rren t Ratin g (A) 0.25 0.375 0.5 0.75 1 1.5 2 2.5 3 3.5 4 Colou r Code (Cover/S tripe) Green Green/White Blue Blue/White Brown Brown/White Black Black/White Violet Violet/White Yellow Ty p. Resistan ce Ty p. Voltage D rop Ty p. P re-arcin g @ 10% Rated @ Rated Cu rren t I 2t @ 3 5 A Cu rren t (O h ms) (Volts) ( A 2 s ec ) 3.0 0.90 .000067 2.0 0.80 .00015 0.9 0.54 .00055 0.51 0.45 .00132 0.15 0.18 .0022 0.068 0.12 .014 0.042 0.11 .037 0.029 0.09 .070 0.022 0.087 .095 0.018 0.08 .185 0.014 0.08 .270 Ty p. O peratin g I2t @ 3 5 A ( A 2 s ec ) .000082 .00017 .00058 .00137 .0026 .015 .038 .078 .107 .190 .272

Notes: 1 AC interrupting rating, melting integral and total clearing integral measured at 32V, unity power factor. 2 3 4 5 DC interrupting rating, melting integral measured at 63V (250mA-3A) and 32V (4-5A) with battery source. It is recommended that fuses be mounted with ceramic (white) side facing up. Contact Bussmann if higher ampere ratings are needed. For long term reliability, operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

Surface Mount Fuses 3216LV/3216CP/3216FF


Agency Approvals: General Description:
v

Bussmann

Order Code: Type: Ratings (A): Rated Voltage:

Packing Code + 3216LV + Rating Fast Acting 250mA to 1.5A 125V ac/dc

Bussmann SMT Chip Fuses utilise a combination of metal film and ultrasonic wire bond technologies for superior fusing action and enhanced reliability. The fuse element is bonded to the substrate and encapsulated with coloured glass, providing excellent short circuit performance and environmental integrity. The end terminations are over-plated with nickel and tin base. Breaking Capacity: 3216FF & 3216LV - 50A @ rated voltage 3216CP - 35A @ rated voltage Time-Current Characteristics: 3216FF & 3216CP - both will carry 100% of rated current for a minimum of 4 hours and will open within 5 seconds at 250% of rated current. The 4A to 5A fuses of the 3216FF will open within 1 second at 350% of rated current. Dimensions (mm):
7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321
3.2

Order Code: Type: Ratings :

Packing Code + 3216CP + Rating Fast Acting 250mA to 5A

Packing Code Prefix:

Rated Voltage: 24V dc Order Code: Type: Ratings : Rated Voltage: Packing Code + 3216FF + Rating Fast Acting 250mA to 6.5A 32V ac / 63V dc (250mA - 3A); 32V dc (4 - 5A)

TR = 3,000 pieces on 8 mm tape on a 178mm reel. TR1 = 15,000 pieces on 8mm tape on a 330mm reel. SP = 50 pieces on tape in a plastic box.

Application Engineers +44 (0)1509 882766 or 882760

7654321 7654321 7654321 7654321 7654321

7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321

1.6

0.9

Surface Mount Fuses

Bussmann
3216FF
Ty p. P re-arcin g @ Ty p. O peratin g I2t @ 5 0 A ( A 2 s ec ) 3 5 A ( A 2 s ec . ) ac .00016 .001 .0014 .0033 .012 .047 .116 .208 .426 .187 .546 .663 2.18 dc .000084 .0002 .0019 .00095 .007 .029 .081 .171 .359 .164 .463 .619 3.21 ac .00017 .0010 .0016 .0033 .014 .048 .136 .210 .507 .208 .550 .668 2.21 dc .0001 .0009 .0026 .0042 .009 .034 .092 .198 .369 .168 .47 .623 3.23 I 2t

Performance data for the 3216 range


P art Nu mber Cu rren t xx = P ackin g Code Ratin g (A) xx/3216F F -250mA xx/3216F F -375mA xx/3216F F -500mA xx/3216F F -750mA xx/3216F F -1A xx/3216F F -1. 5A xx/3216F F -2A xx/3216F F -2. 5A xx/3216F F -3A xx/3216F F -4A xx/3216F F -4. 5A xx/3216F F -5A xx/3216F F -6. 5A 250mA 375mA 500mA 750mA 1A 1.5A 2A 2.5A 3A 4A 4.5A 5A 6.5A P art Markin g .25 White Dot 0.5 .75 1 1.5 2 2.5 3 4 4.5 5 6.5 Ty p. Resistan ce @ 10% Rated Cu rren t (O h ms) 4.5 1.8 1.15 .75 .168 .098 .063 .046 .037 .019 .014 .013 .0085 Ty p. Voltage D rop @ Rated Cu rren t (Volts) 1.4 .73 .66 .63 .20 .18 .16 .14 .13 .11 .10 .09 .076

3216LV
xx/3216LV-250mA xx/3216LV-375mA xx/3216LV-500mA xx/3216LV-750mA xx/3216LV-1A xx/3216LV-1. 25A xx/3216LV-1. 5A 250mA 375mA 500mA 750mA 1A 1.25A 1.5A .25 White Dot 0.5 .75 1 White D 1.5 4.50 1.80 1.15 .75 .52 .40 .26 1.4 .73 .66 .63 .63 .62 .49 .00016 .001 .0014 .0033 .020 .035 .038 .000084 .0002 .0019 .00095 .0084 .021 .024 .00017 .0010 .0016 .0033 .022 .038 .044 .0001 .0009 .0026 .0042 .0098 .027 .033

3216C P
xx/3216CP-250mA xx/3216CP-375mA xx/3216CP-500mA xx/3216CP-750mA xx/3216CP-1A xx/3216CP-1. 5A xx/3216CP-2A xx/3216CP-2. 5A xx/3216CP-3A xx/3216CP-4A xx/3216CP-4. 5A xx/3216CP-5A 250mA 375mA 500mA 750mA 1A 1.5A 2A 2.5A 3A 4A 4.5A 5A 4.5 1.8 1.15 .75 .168 .098 .063 .046 .037 .019 .014 .013 1.4 .73 .66 .63 .20 .18 .16 .14 .13 .11 .10 .09

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

Surface Mount Fuses 6125T


Agency Approvals: Designed to comply with IEC127-4. General Description:
Order Code: Type: Ratings : Rated Voltage: Packing Code + 6125T + Rating Time Delay 250mA to 5A 125V ac/dc

Bussmann

Bussmann surge resistant time delay fuse with brazed sealed body and end plates, compatible with wave soldering. The fuse has excellent environmental integrity. Breaking Capacity: 50A ac @ rated voltage, power factor = 1.0 50A dc @ rated voltage battery source

Time Current Characteristics: 125% of rating: 1 hour minimum carry. 200%: open within 2 minutes. 1000%: open within 0.01 to 0.1 seconds. Dimensions (mm):

2.5

6.1

2.5

Packing Code Prefix:

TR = 1,000 pieces on 12mm tape on a 178mm reel SP = 50 pieces on 12mm tape in plastic box

Performance Data
P art Nu mber xx = P ackin g code xx/6125T-250mA xx/6125T-500mA xx/6125T-1A xx/6125T-1. 5A xx/6125T-2A xx/6125T-3A xx/6125T-4A xx/6125T-5A Cu rren t Ratin g 250mA 500mA 1A 1.5A 2A 3A 4A 5A Markin g B.25 B0.5 B1A B1.5 B2A B3A B4A B5A Ty p. Resistan ce Max. P ower Loss @ @ 10% Rated 125% of Rated Cu rren t (O h ms) Cu rren t (mW) 4.5 500 1.0 500 0.25 500 0.10 500 0.06 500 0.04 1000 0.03 1200 0.02 1200

Application Engineers +44 (0)1509 882766 or 882760

Surface Mount Fuses


Agency Approvals: General Information: The Bussmann SMD Tron is designed to EIA-PD-100, DWG SOPM-7243. A high temperature body material is capable of surviving a 60 second exposure to a temperature of 215 degrees centigrade in a flourinert FC5311 environment. Because the SMD Tron is totally sealed, it can be subjected to cleaning by a wide variety of aggressive solvents. Dimensions (mm):

Bussmann

SFT

7.5

Order Code: Packing Code + SFT + Rating 4.3 Type: Fast Acting, Current Limiting 63mA to 12.5A 63mA to 5A -125V ac/dc 7A to 10A - 60V ac/ 90V dc 1000 = 0.54kg

Construction:Solid Matrix 3.05 1.27 2.3 Ratings: Rated Voltage:

Packing Code Prefix:

TR/SFT - 500 pcs on a 178mm reel, 16mm tape. TR1/SFT - 2000 pcs on a 330.2mm reel, 16mm tape, (also available on a 12mm tape).

Weight:

Time current characteristics: 63mA to 10A at 100% of rating - 4 hours minimum, 63mA to 10A at 250% of rated current - 5 seconds maximum. 12.5A - consult Bussmann.

Performance Data
P art Nu mber xx = P ackin g code xx/S F T-63mA xx/S F T-125mA xx/S F T-250mA xx/S F T-375mA xx/S F T-500mA xx/S F T-750mA xx/S F T-1A xx/S F T-1. 5A xx/S F T-2A xx/S F T-2. 5A xx/S F T-3A xx/S F T-3. 5A xx/S F T-4A xx/S F T-5A xx/S F T-7A xx/S F T-10A xx/S F T-12. 5A Rated Cu rren t D 63mA 125mA 250mA 375mA 500mA 750mA 1A 1.5A 2A 2.5A 3A 3.5A 4A 5A 7A 10A 12.5A Rated Voltage (V) ac (max) dc (max) 125 125 125 125 125 125 125 125 125 125 125 125 125 125 60 60 48 125 125 125 125 125 125 125 125 125 125 125 125 125 125 90 90 Breakin g Capacity A ac 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A dc 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A Ty p. P re-arcin g I2t ( A 2 s ec ) ac TBA TBA 7.49 x 10 - 5 3.17 x 10 - 4 4.46 x 10 - 4 1.72 x 10 - 3 .01 .03 .08 .18 .34 .50 .89 1.73 TBA TBA 15 dc TBA TBA 5.1 x 10 - 6 2.18 x 10 - 5 3.8 x 10 - 5 2.27 x 10 - 4 .007 .020 .07 .14 .24 .38 .68 1.29 TBA TBA TBA Ty pical O peratin g I 2 t ( A 2 s ec ) ac TBA TBA 2.0 x 10 - 4 4.18 x 10 - 4 5.74 x 10 - 4 2.59 x 10 - 3 .011 .035 .089 .238 .44 .636 1.07 2.38 TBA TBA 20 dc TBA TBA 6.29 x 10 - 6 2.67 x 10 - 5 4.63 x 10 - 5 2.77 x 10 - 4 .008 .025 .081 .16 .27 .47 .78 1.36 TBA TBA TBA
C

Ty pical Voltage D ropB Volts at Rated Cu rren t

A g en c y Approvals 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

0.8 0.75 0.66 0.525 0.12 0.2 0.17 0.145 0.13 0.155 0.135 0.125 0.114 0.13 0.09

Notes: A. Breaking Capacity was measured at 1.0 power factor on AC and a time constant less than 1ms on DC. B. Voltage drop was measured at 25 deg. C 3 deg. C ambient temperature at rated current with device mounted on a circuit trace. C. I2t measured at 50 amp, 125V AC , .95PF, random closing angle; 300 amps, 125V DC, TC <1ms. D. Device designed to carry 125% of rated current for one hour minimum. For long term reliability an operating current of 80% or less of rated current is recommended, with further derating at elevated ambient temperatures.

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

Axial and Radial Leaded Fuses MCR


Agency Approvals: Designed to UL248-14. General Information:

Bussmann

Order Code: Packing Code + MCR + Rating Type: Fast Acting, Current Limiting

Ratings : 63mA to 10A Rated Voltage: 0.0625 to 5A - 125V ac/dc 7 & 10A - 60V ac/90V dc

The Microtron subminiature fuse is designed to safely interrupt 50 amperes at 125V ac. This excellent performance is achieved at power factors as low as 97%. Competitive components claim similar short circuit interrupting ratings, but at 100% power factor - a condition that rarely exists in real world applications. In addition, the Microtron is capable of interrupting a 300 ampere fault at 125V dc. Dimensions (mm):

Packing Code Prefix: Blank = TR/ = TR1/ = TR6/ = 10s BK = 500s Tape/Reel 2,500 units, 52.4mm spacing Tape/Reel 5,000 units, 52.4mm spacing Tape/Reel 1,000 units, 52.4mm spacing

Radial leaded versions available 10.16mm & 15.24mm lead spacing.

Perfomance Data
P art Nu mber xx = P ackin g Co de xx/MCR-63mA xx/MCR-125mA xx/MCR-250mA xx/MCR-375mA xx/MCR-500mA xx/MCR-750mA xx/MCR-1A xx/MCR-1. 5A xx/MCR-2A xx/MCR-2. 5A xx/MCR-3A xx/MCR-3. 5A xx/MCR-4A xx/MCR-5A xx/MCR-7A xx/MCR-10A Notes: 1 2 Breaking Capacity was measured at 100% (0.0625 to 7A) power factors on ac and a time constant less than 1ms on dc. I2t was measured at 50 amps 125V ac 0.95 PF (random closing angle) and 300 amps 125V dc, TC <1ms for 0.0625A to 5A and 50A 60V ac, 0.95PF (random closing angle) and 300 amps 90V dc, TC <1ms for the 7 and 10A fuses. All values shown above are typical. Rated Cu rren t 63mA 125mA 250mA 375mA 500mA 750mA 1A 1.5A 2A 2.5A 3A 3.5A 4A 5A 7A 10A Breakin g Capacity 1 ac 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A dc 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A 300A P re-arcin g I2t (A2 sec)2 ac 1.1 x 10 - 6 4.3 x 10 - 6 8.0 x 10 - 5 9.7 x 10 - 5 7.4 x 10 - 4 1.3 x 10 - 3 0.01 0.03 0.09 0.09 0.35 0.56 0.96 1.82 1.48 3.62 dc 1.0 x 10 - 7 7.1 x 10 - 7 1.0 x 10 - 6 6.7 x 10 - 6 5.4 x 10 - 5 7.4 x 10 - 5 0.01 0.02 0.07 0.14 0.28 0.37 0.67 1.34 0.49 1.16 Ty pical O peratin g I 2 t ( A 2 s ec ) ac 1.8 x 10 - 6 7.3 x 10 - 6 1.2 x 10 - 4 1.1 x 10 - 4 6.2 x 10 - 3 7.5 x 10 - 2 0.02 0.04 0.11 0.25 0.45 0.83 1.37 2.53 2.02 4.41 dc 1.5 x 10 - 7 8.7 x 10 - 7 1.3 x 10 - 6 8.3 x 10 - 6 6.8 x 10 - 5 9.2 x 10 - 5 0.01 0.03 0.08 0.17 0.32 0.43 0.77 1.51 0.58 1.38
2

Ty pical Voltage D rop Volts at 100% Rated Cu rren t 2.33 1.52 0.76 0.73 0.65 0.55 0.24 0.20 0.16 0.15 0.15 0.14 0.13 0.11 0.10 0.08

Agen cy Approvals

8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Application Engineers +44 (0)1509 882766 or 882760

Axial and Radial Leaded Fuses

Bussmann

ETF and EFF Radial Lead Micro Fuse


Agency Approvals:
v

SEMKO and VDE approved except 5A and 6.3A which are not included in the standard. All are UL recognised and have CSA acceptance. General Information: ETF Time Delay radial leaded micro fuse in accordance with the specifications of IEC60127-3, standard sheet 4 (Type T). EFF Fast Acting radial leaded micro fuse in accordance with the specifications of IEC60127-3, standard sheet 3 (Type F) Dimensions (mm):
Short Lead A B C D E F Lead 8.35 0.1 7.7 0.1 4.3 0.3 0.5 min 5.08 0.1 0.6 0.1 Long Lead 8.35 0.1 7.7 0.1 18.8 0.3 0.5 min 5.08 0.1 0.6 0.1 Order Code: Packing Code + ETF + Rating Type: Ratings: Rated Voltage: Time Delay 80mA to 6.3A 250V ac

Order Code: Packing Code + EFF + Rating Type: Ratings: Rated Voltage: Fast Acting 250mA to 1.5A 250V ac

Breaking Capacity:

35A or 10 times rated current (whichever is the greater).

Markings: ETF marked as dimension drawing above, EFF marked with an F in place of the letter T. Packing Codes: AP = Ammo packed 1000 per box; BK = in bulk 100 per bag (short leaded only). Weight is 573 grams per 1000 pieces.

ETF Operating Characteristics


Rated Current 1.5In M in 80mA to 6.3A 1 hr. 2.1In M ax 2.75In M in M ax M in 4In M ax 3 sec M in 20ms 10In M ax 150ms

2 min 400ms 10 sec 150ms

EFF Operating Characteristics


Rated Current 1.5In M in 250mA to 5A 1 hr. 2.1In M ax 2.75In M in M ax 3 sec M in 3 ms 4In M ax 10In M ax

30 min 10 ms

300ms 20 ms

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

Axial and Radial Leaded Fuses ETF and EFF Radial Lead Micro Fuse
ETF Performance Data
P art Nu mber xx = P ackin g Co de xx/ET F 80 xx/ET F 100 xx/ET F 125 xx/ET F 160 xx/ET F 200 xx/ET F 250 xx/ET F 315 xx/ET F 400 xx/ET F 500 xx/ET F 630 Ratin g Cold Resistan ce O h ms 20% 3.3 2.2 1.5 1.0 0.7 0.5 0.38 0.28 0.21 0.16 Max. mV Ty p. P reD rop P art Nu mber arcin g I2t measu red xx = P ackin g @ 10 I n at In n ormal 2 s ec ) C o d e (A ambien t 400 350 300 280 250 220 190 160 150 130 0.01 0.02 0.04 0.06 0.11 0.41 0.66 1.05 1.66 2.60 xx/ET F 800 xx/ET F 1 xx/ET F 1. 25 xx/ET F 1. 6 xx/ET F 2 xx/ET F 2. 5 xx/ET F 3. 15 xx/ET F 4 xx/ET F 5 xx/ET F 6. 3 Ratin g Cold Resistan ce O h ms 20% 0.12 0.09 0.06 0.047 0.035 0.026 0.019 0.014 0.010 0.008

Bussmann

Max. mV Ty p. P reD rop arcin g I2t measu red @ 10 I n at In n ormal ( A 2 s ec ) ambien t 120 110 100 95 90 87 83 80 77 73 4.2 6.7 11 17 27 43 69 110 175 281

80mA 100mA 125mA 160mA 200mA 250mA 315mA 400mA 500mA 630mA

800mA 1.0 1.25 1.6 2.0 2.5 3.15 4.0 5.0 6.3

Contact Bussmann for availability

EFF Performance Data


P art Nu mber xx = P ackin g Co de xx/EF F 250 xx/EF F 315 xx/EF F 400 xx/EF F 500 xx/EF F 630 xx/EF F 800 xx/EF F 1 Ratin g Cold Resistan ce O h ms 20% 0.45 0.34 0.25 0.19 0.091 0.071 0.055 M ax mV Ty p. P reP art Nu mber D rop arcin g I2t xx = P ackin g measu red at @10 In Co de In ( A 2 s ec ) 260 250 240 235 110 105 100 0.29 0.05 0.08 0.15 0.12 0.21 0.36 xx/EF F 1. 25 xx/EF F 1. 6 xx/EF F 2 xx/EF F 2. 5 xx/EF F 3. 15 xx/EF F 4 xx/EF F 5 Ratin g Cold Resistan ce O h ms 20% 0.043 0.034 0.026 0.020 0.016 0.012 0.010 M ax mV Ty p. P reD rop arcin g I2t measu red at @10 In In ( A 2 s ec ) 100 95 95 90 90 85 85 0.61 1.1 1.8 3.1 5.3 9.0 16.0

250mA 315mA 400mA 500mA 630mA 800mA 1A

1.25A 1.6A 2A 2.5A 3.15A 4A 5A

10

Application Engineers +44 (0)1509 882766 or 882760

Axial and Radial Leaded Fuses

Bussmann

Subminiature PC-TRON Radial Lead Fuse


Agency Approvals:

General Information: At 250V ac, the 0.5 to 3A PC-TRON can safely interrupt 50 amperes; at 125V ac, the 0.5 to 5A versions can interrupt 10,000 amperes. This high breaking capacity makes the PC-TRON subminiature fuse ideal for line-side protection of power supplies.

Order Code: Packing Code + PC + Catalogue Symbol (see below) + Rating Type: Fast Acting PCB, PCC, PCF & PCH 500mA to 2.5A PCB, PCC, PCF & PCH 2.6A to 3.0A PCD, PCE, PCG & PCI 5.0A Rated Voltage: PCB, PCC, PCF & PCH 250V ac, 450V dc PCB, PCC, PCF & PCH 250V ac, 350V dc PCD, PCE, PCG & PCI 125V ac, 250V dc Ratings:

Dimensions (mm):

Catalogue Symbols: PCB = Full lead length (250V) 0.5 to 3A PCC = Short lead length* (250V) 0.5 to 3A PCD = Full lead length (125V) 5A PCE = Short lead length* (125V) 5A PCF = 10.16mm lead spacing 0.5 to 3A PCG = 10.16mm lead spacing 5A PCH = 0.5 to 3A PCI = 5A * Short lead length not available in Tape & Reel Packing Code Prefix: Blank = BK = TR = Characteristics: Carry 100% of rating for 4 hrs. minimum. Open at 200% of rating in 10 sec. maximum. Standard pack of 5 Bulk Packed 100 Tape & Reel 500

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

11

5 x 15mm Fuses C515 (Axial Leads) and C519


Agency Approvals: General Information:

Bussmann

5 x 15mm glass fuse available with (C515) or without (C519) axial leads. The fuse is available with an optional sleeve of flexible fluoropolymer (UL flammability rating VW-1). The tube will self-extinguish within one minute.
Order Code: Packing Code + C519 + Rating Type: Size: Time Delay 5 x 15mm

Dimensional Data (mm):

Construction: Glass Tube, silver plated brass end caps. Ratings: Rated Voltage: 125mA to 5A 125mA to 3A - 250V ac 3.5A to 7A - 125V ac

Packing Code Prefix: BK - bulk package (100 pcs.); TR - Tape & Reel (500 pcs.) TR1 - Tape & Reel (1000 pcs.); TR2 - Tape & Reel (1500 pcs.) Tape & Reel packaging (C518 only) per EIA 296-E (10.2mm component pitch and 52.4mm tape-to-tape spacing). Only type C515 is available in tape and reel format. Insert S after the product reference if you want the sleeve. For example BK/C515S750.

Performance Data
P art Nu mber xx = P ackin g Co de Ratin g Breakin g Capacity M ax mV @ In 1300 670 550 510 35A/250V ac 10kA/125V ac p.f. = 0.7 - 0.8 430 320 310 250 250 230 100A/250V ac 10kA/125V ac p.f. = 0.7 - 0.8 220 180 210 190 170 170 400A/125V ac p.f. = 1.0 160 150 130 Max. Min I2t power @ Loss (W) 10In ( A 2s ) @ In 0.16 0.17 0.19 0.19 0.22 0.19 0.23 0.25 0.31 0.35 0.35 0.36 0.47 0.48 0.51 0.60 0.64 0.75 0.91 0.084 0.26 1.2 1.3 1.6 2.5 2.5 6.5 10.0 12.0 15.0 27.0 30.0 47.0 51.0 64.0 123.0 175.0 426.0 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

xx/C519-125mA 125mA 35A/250V 10kA/125V ac p.f. = 0.7 - 0.8 xx/C519-250mA 250mA 35A/250V 10kA/125V ac xx/C519-350mA 350mA 25A/600V only p.f. =1.0 xx/C519-375mA 375mA xx/C519-500mA 500mA xx/C519-600mA 600mA xx/C519-750mA 750mA xx/C519-1A xx/C519/1. 25A 1A 1.25A 1.5A 1.6A 2A 2.25A 2.5A 3A 3.5A 4A 5A 7A*

Order Code: Packing Code + C515 + Rating Specification as C519 but with 33.5mm Axial Leads Ratings: 125mA to 7A

xx/C519-1. 5A xx/C519-1. 6A xx/C519-2A xx/C519-2. 25A xx/C519-2. 5A xx/C519-3A xx/C519-3. 5A xx/C519-4A xx/C519-5A xx/C515-7A

* C515 only.

12

Application Engineers +44 (0)1509 882766 or 882760

5 x 15mm Fuses

Bussmann

Time Current Characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

13

5 x 15mm Fuses C518 (Axial Leaded) and C520


Agency Approvals:

Bussmann

General Information: 5 x 15mm glass fuse available with (C518) and without (C520) axial leads. The fuse is available with an optional sleeve of flexible fluoropolymer (UL flammability rating VW-1). The tube will self extinguish within one minute. Dimensional Data (mm):

Order Code: Packing Code + C520 + Rating Type: Size: Fast Acting 5 x 15mm

Construction: Glass tube, electroplated brass end caps. Ratings: Rated Voltage: 100mA to 5A 250V ac

Packing Code Prefix: BK - bulk package (100 pcs.); TR - Tape & Reel (500 pcs.); TR1 - Tape & Reel (1000 pcs.); TR2 - Tape & Reel (1500 pcs.) Tape and Reel packaging (for C518 only) per EIA 296-E (10.2mm component pitch and 52.4mm tape-to-tape spacing). Only the C518 is available in tape and reel format. Insert S after the product reference if you want the sleeve. For example BK/C518S250.

Performance Data
P art Nu mber xx = P ackin g Co de xx/C518-100mA Ratin g 100mA 125mA 250mA 375mA 500mA 750mA 2A 2.5A 3A 3.5A 4A 5A 200A/250V 10kA/125V ac p.f. = 0.7 - 0.8 100A/250V ac 10kA/125V ac p.f. = 0.7 - 0.8 35A/250V ac 10kA/125V ac p.f. = 0.7 - 0.8 Breakin g Capacity Max. mV @ In 3100 2800 2200 1500 1300 1000 190 180 160 140 TBA 130 Max. P ower Loss (W) @ In 0.31 0.35 0.55 0.56 0.65 0.75 0.38 0.45 0.48 0.49 TBA 0.65 Max. I2t @ 10I n ( A 2s ) 0.0010 0.0022 0.016 0.053 0.13 0.37 2.3 4.1 6.8 11.0 TBA 13.0 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

Order Code: Packing Code + C518 + Rating Specification as C519 but with 33.5mm Axial Leads

xx/C518-125mA xx/C518-250mA xx/C518-375mA xx/C518-500mA xx/C518-750mA xx/C518-2A xx/C518-2. 5A xx/C518-3A xx/C518-3. 5A xx/C518-4A xx/C518-5A

14

Application Engineers +44 (0)1509 882766 or 882760

5 x 15mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

15

5 x 15mm Fuses C517 (Axial Leads)


Agency Approvals:
v

Bussmann

General Information: 5 x 15mm glass fuse only available with axial leads, used as lighting ballast protection. An optional sleeve of flexible fluoropolymer (UL flammability rating VW-1) is available. The tube will self extinguish within one minute.

Dimensional Data (mm):

Order Code: Packing Code + C517 + Rating Type: Size: Fast Acting, lighting ballast protection. 5 x 15mm

Construction:Ceramic tube, electro plated brass end caps. Ratings: Rated Voltage: 2A to 5A 350V ac

Packing Code Prefix: BK - bulk package (100 pcs.); TR - Tape & Reel (500 pcs.); TR1 - Tape & Reel (1000 pcs.); TR2 - Tape & Reel (1500 pcs.) Tape and reel packaging per EIA296-E (10.2mm component pitch and 52.4mm tape-to-tape spacing. Insert S after the product reference if you want the sleeve. For example BK/C517S3.

Performance Data
Ratin g 2A 3A 5A 10kA p.f. = 0.7 - 0.8 Breakin g Capacity at 125V Breakin g Capacity at 250V 100A p.f. = 0.7 - 0.8 200A p.f. = 0.7 - 0.8 Breakin g Capacity at 350V Max. mV @ In 190 100A p.f. = 1.0 160 130 Max. P ower Loss (W) @ In 0.38 0.48 0.65 Min . I2t @ 10I n ( A 2s ) 1.2 4.05 8.0 6 6 6 6 6 6 6 6 6 6
v

16

Application Engineers +44 (0)1509 882766 or 882760

5 x 15mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

17

5 x 20mm Fuses S501 (GDA and GDA-V Axial Leads)


Agency Approvals: Designed to IEC 60127-2-1

Bussmann

Dimensions (mm):
Order Code: S501 + Rating GDA + Rating (USA) GDA-V + Rating Type: Size: Fast Acting, High Breaking Capacity. 5 x 20mm

Construction: Ceramic Tube, electroplated end caps. Ratings: Rated Voltage: Packing: Weight: 50mA to 10A 250V ac 10s, 100s, 1000s 1000 = 1 kg

Breaking Capacity: 1500A 250V, 50Hz pf 0.7 - 0.8

Performance Data
Ratin g 50m A 63m A 80m A 100m A 125m A 160m A 200m A 250m A 315m A 400m A 500m A 630m A 800m A 1. 0A 1. 25A 1. 6A 2. 0A 2. 5A 3. 15A 4. 0A 5. 0A 6. 3A 8. 0A 10. 0A M ax mV @ In 10000 3200 3000 2600 2000 1700 1600 1500 1500 1300 360 340 300 240 230 190 220 200 170 160 140 130 130 130 Max. P ower Loss (W) @ 1. 5 I n 1.2 0.57 0.65 0.65 0.65 0.67 0.72 0.84 1.2 1.3 0.53 0.67 0.73 0.86 1.0 1.0 1.6 1.7 1.8 2.0 2.6 2.7 Min . P rearcin g I2t @ 1 0 I n ( A 2s ) 0.000250 0.000635 0.00146 0.00290 0.00391 0.00717 0.0108 0.0356 0.0149 0.0240 0.238 0.456 0.832 0.330 0.906 1.280 1.6 3.0 5.56 11.04 20.5 36.9 64.0 100.0 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

18

Application Engineers +44 (0)1509 882766 or 882760

5 x 20mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

19

5 x 20mm Fuses S500 (GDB and GDB-V Axial Leads)


Agency Approvals: Designed to IEC60127-2-2 Dimensions (mm):

Bussmann

Order Code:

S500 + Rating GDB + Rating (USA) GDB-V + Rating Fast Acting, Low Breaking Capacity. 5 x 20mm Glass Tube, electroplated end caps. 32mA to 10A 250V ac 10s, 100s, 1000s 1000 = 0.62 kg

Type: Size: Construction: Ratings: Rated Voltage: Packing: Weight:

Breaking Capacity: 32mA to 3.15A - 35A @ 250V, 50Hz pf 1.0 4A to 10A - 10 x In 250V, 50Hz pf 1.0

Performance Data
Ratin g 32m A 40m A 50m A 63m A 80m A 100m A 125m A 160m A 200m A 250m A 315m A 400m A 500m A 630m A 800m A 1. 0A 1. 25A 1. 6A 2. 0A 2. 5A 3. 15A 4. 0A 5. 0A 6. 3A 8. 0A 10. 0A M ax mV @ In 3200 2500 2400 2000 1200 1100 1000 2000 1700 1400 1300 1100 220 220 190 200 200 190 150 150 130 130 120 120 120 110 Max. P ower Loss (W) @ 1. 5 I n 0.21 0.21 0.25 0.26 0.27 0.30 0.35 0.79 0.82 0.82 1.0 1.0 0.31 0.44 0.46 0.73 1.0 1.2 1.2 1.3 1.7 1.7 1.9 2.4 Min . P rearcin g I2t @ 1 0 I n ( A 2s ) 0.0000307 0.000058 0.000100 0.000167 0.000448 0.00110 0.00266 0.00614 0.00640 0.0250 0.0367 0.0880 0.0120 0.0159 0.0256 0.450 0.656 1.19 3.32 5.31 9.92 20.0 32.5 59.5 134.4 230.0 Application Engineers +44 (0)1509 882766 or 882760 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

20

5 x 20mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

21

5 x 20mm Fuses

Bussmann

S504 and S504-V (Axial Leads) GDC and GDC-V (Axial Leads)
Agency Approvals: Designed to IEC60127-2-3 Dimensions (mm):

Order Code: S504 + Rating S504-V + Rating GDC + Rating (USA) GDC-V + Rating (USA) Type: Size: Time-delay, Low Breaking Capacity. 5 x 20mm

Construction:Glass tube, electroplated brass end caps. Ratings: Rated Voltage: Packing: Weight: 32mA to 6.3A (S504) 32mA to 400mA (GDC) 250V ac 10s, 100s, 1000s 1000 = 0.785kgs
Ratin g 32m A 40m A 50m A 63m A 80m A 100m A 125m A 160m A 200m A 250m A 315m A 400m A 500m A 630m A 800m A 1. 0A 1. 25A 1. 6A 2. 0A 2. 5A 3. 15A 4. 0A 5. 0A 6. 3A M ax mV @ In 1100 960 860 800 610 520 420 340 360 290 270 230 200 180 180 140 120 120 115 110 100 95 95 95 Max. P ower Min . P re-arcin g Loss (W) @ 2 I t @ 1 0I n ( A 2s ) 1. 5 I n 0.14 0.17 0.17 0.17 0.18 0.18 0.18 0.21 0.33 0.33 0.33 0.33 0.36 0.36 0.55 0.55 0.55 0.59 0.74 0.84 0.93 1.1 1.5 1.6 0.0038 0.0054 0.0072 0.017 0.030 0.035 0.050 0.076 0.10 0.20 0.53 0.80 1.2 1.7 3.7 4.7 6.8 15 24 37 65 62 140 215 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

Breaking Capacity: 32mA to 3.15A - 35A @ 250V ac 50Hz pf 1.0 4A to 6.3A - 250V ac, 50Hz pf 1.0

Performance Data

N.B. GDC and GDC-V only available from 32mA to 400mA inclusive.

22

Application Engineers +44 (0)1509 882766 or 882760

5 x 20mm Fuses

Bussmann

Time current characteristics

GDC and GDC-V only available up to 400mA

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

23

5 x 20mm Fuses S505 and S505-V (Axial Leads)


Agency Approvals: Designed to IEC60127-2-5 Dimensions (mm):

Bussmann

Order Code: Type: Size: Construction:

S505 + Rating Time-Delay, High Breaking Capacity. 5 x 20mm Ceramic Tube, electro-plated brass end caps. 500mA to 10A 250V ac 10s, 100s, 1000s 1000 = 1.2kgs

Ratings: Rated Voltage: Packing: Weight:

Breaking Capacity: 1500A at 250V, 50Hz, pf 0.7 - 0.8

Performance Data
Ratin g 500m A 800m A 1. 0A 1. 25A 1. 6A 2. 0A 2. 5A 3. 15A 4. 0A 5. 0A 6. 3A 8. 0A 10. 0A M ax mV @ In 360 280 170 150 130 110 100 90 85 80 75 75 80 Max. P ower Loss (W) @ 1. 5 I n 0.62 0.72 0.48 0.49 0.52 0.56 0.59 0.71 0.90 1.0 1.1 1.6 3.6 Min . P rearcin g I2t @ 10I n ( A 2s ) 0.14 0.46 1.0 1.6 3.0 5.6 12 21 43 72 135 230 290 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

24

Application Engineers +44 (0)1509 882766 or 882760

5 x 20mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

25

5 x 20mm Fuses S506 (GDC, GDC-V Axial Leads)


Agency Approvals:

Bussmann

Designed to IEC60127-2-3 Dimensions (mm):

Order Code:

S506 + Rating GDC + Rating (USA) GDC-V + Rating Time-Delay, Low Breaking Capacity 5 x 20mm Glass Tube, electroplated end caps 500mA to 12.5A 250V ac 10s, 100s, 1000s 1000 = 0.81kgs

Type: Size: Construction: Ratings: Rated Voltage: Packing: Weight:

Breaking Capacity: 35A at 250V (500mA to 3.15A), 10 x In at 250V (4A to 12.5A). Power factor 1.0

Performance Data
Ratin g 500m A 630m A 800m A 1. 0A 1. 25A 1. 6A 2. 0A 2. 5A 3. 15A 4. 0A 5. 0A 6. 3A 8. 0A 10. 0A 12. 5A Max. P ower M ax mV Loss (W) @ @ In 1. 5 I n 190 170 150 90 85 85 85 85 80 80 75 75 80 75 75 0.27 0.32 0.36 0.23 0.27 0.33 0.44 0.46 0.57 0.79 0.97 1.1 Min . P rearcin g I2t @ 10I n ( A 2s ) 0.67 1.0 2.2 2.7 6.7 9.7 15 25 51 88 150 214 192 420 812 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

26

Application Engineers +44 (0)1509 882766 or 882760

5 x 20mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

27

5 x 20mm Fuses S508


Agency Approvals:

Bussmann

Designed to IEC60127-2-6 Dimensions (mm):

Order Code: Type:

S508 + Rating Time Delay, Enhanced Breaking Capacity 5 x 20mm Glass Tube, electroplated end caps 32mA to 3.15A 250V ac

Breaking Capacity:

150A @ 250V ac pf 1

Size: Construction: Ratings: Rated Voltage:

Performance Data
Ratin g 32m A 40m A 50m A 63m A 80m A 100m A 125m A 160m A 200m A 250m A 315m A 400m A 500m A 630m A 800m A 1. 0A 1. 25A 1. 6A 2. 0A 2. 5A 3. 15A M ax mV @ In 1100 960 860 800 610 520 420 340 360 290 270 230 190 170 150 90 85 85 85 85 80 Max. P ower Loss (W) @ 1. 5 I n 0.14 0.17 0.17 0.17 0.18 0.18 0.18 0.21 0.33 0.33 0.33 0.33 0.27 0.32 0.36 0.23 0.27 0.33 0.44 0.46 0.57 Min . P rearcin g I2t @ 1 0 I n ( A 2s ) 0.0038 0.0054 0.0072 0.017 0.030 0.035 0.050 0.076 0.10 0.20 0.53 0.80 0.67 1.0 2.2 2.7 6.7 9.7 15 25 51 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

28

Application Engineers +44 (0)1509 882766 or 882760

5 x 20mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

29

5 x 20mm Fuses GMA and GMA-V (Axial Leads)


Agency Approvals: Designed to UL248-14

Bussmann

Dimensions (mm):
Order Code: GMA or GMA-V + Rating (GMA-V fitted with Axial Leads) Type: Size: Fast Acting 5 x 20mm

Construction:Glass Tube, electroplated brass end caps. Ratings: Rated Voltage: Packing: Weight: 63mA to 15A 63mA-3A - 250V ac 3.15A-15A - 125V ac 10s, 100s, 1000s 1000 = 0.73kg

Performance Data
Ratin g 63m A 100m A 125m A 200m A 250m A 300m A 315m A 500m A 600m A 750m A 800m A 1. 0A 1. 2A 1. 25A 1. 5A 1. 6A 2. 0A 2. 5A 3. 0A 3. 15A 3. 5A 4. 0A 5. 0A 6. 0A 7. 0A 8. 0A 10. 0A 15. 0A 200A/125V ac p.f. = 1.0 150A/125V ac p.f. = 1.0 10kA/125V ac p.f. = 0.7 - 0.8 100A/250V ac 10kA/125V ac p.f. = 0.7 - 0.8 35A/250V ac 10kA/125V ac p.f. =0.7 - 0.8 Breakin g Capacity M ax mV @ In 4900 4300 3700 3600 2300 500 500 230 210 210 200 300 300 300 270 260 240 220 220 220 210 210 200 170 120 110 110 100 Max. P ower Min . P reLoss (W) arcin g I2t @ @ In 1 0 I n ( A 2s ) 0.31 0.43 0.46 0.72 0.58 0.15 0.16 0.12 0.13 0.16 0.16 0.30 0.36 0.38 0.41 0.42 0.48 0.55 0.66 0.69 0.74 0.84 1.0 1.0 0.84 0.88 1.1 1.5 0.000833 0.00180 0.00359 0.00800 0.0150 0.0198 0.0218 0.103 0.180 0.456 0.518 0.520 0.720 0.766 1.35 1.28 2.40 4.63 7.20 7.94 10.2 14.4 25.0 39.6 93.1 141 270 630 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

30

Application Engineers +44 (0)1509 882766 or 882760

5 x 20mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

31

5 x 20mm Fuses GMC and GMC-V (Axial Leads)


Agency Approvals: Designed to UL 248-14. Dimensions (mm):

Bussmann

Order Code: GMC or GMC-V + Rating Type: Size: Medium Time Delay 5 x 20mm

Construction: Glass Tube, electroplated brass end caps. Ratings: Rated Voltage: Packing: Weight: 50mA to 10A
Ratin g Breakin g Capacity Max. mV @ In 1600 1400 1400 1200 1000 800 730 650 35A/125V ac 10kA/125V ac p.f. = 0.7 - 0.8 490 580 480 510 370 360 360 340 320 290 250 200 190 100A/250V ac 10kA/125V ac p.f. = 0.7 - 0.8 160 130 130 130 130 130 10kA/125V ac p.f. = 0.7 - 0.8 120 120 120 120 200A/125V ac p.f. =1.0 120 110 110 Min . P reMax. P ower arcin g I2t Loss (W) @ 10I n @ In ( A 2s ) 0.080 0.088 0.11 0.12 0.13 0.12 0.12 0.13 0.12 0.17 0.15 0.20 0.19 0.22 0.23 0.24 0.24 0.23 0.25 0.25 0.29 0.26 0.26 0.33 0.39 0.41 0.46 0.48 0.60 0.72 0.76 0.84 0.88 1.10 0.0032 0.0040 0.0064 0.010 0.016 0.023 0.026 0.040 0.063 0.090 0.099 0.16 0.37 0.50 0.55 0.88 0.9 0.9 1.0 2.5 3.6 4.8 6.0 6.8 10 16 19 28 45 79 79 93 154 270 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

50mA to 3.15A - 250V ac 3.5A to 10A - 125V ac 10s, 100s, 1000s 1000 = 0.74kg

50m A 63m A 80m A 100m A 125m A 150m A 160m A 200m A 250m A 300m A 315m A 400m A 500m A 600m A 630m A 700m A 750m A 800m A 1. 0A 1. 25A 1. 5A 1. 6A 2. 0A 2. 5A 3. 0A 3. 15A 3. 5A 4. 0A 5. 0A 6. 0A 6. 3A 7. 0A 8. 0A 10. 0A

Performance Data

32

Application Engineers +44 (0)1509 882766 or 882760

5 x 20mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

33

5 x 20mm Fuses GMD and GMD-V (Axial Leads)


Agency Approvals: Designed to UL 248-14

Bussmann

Dimensions (mm):
Order Code: GMD or GMD-V + Rating Type: Size: Construction: Time Delay 5 x 20mm Glass Tube, electroplated brass end caps. 125mA to 4A 250V ac 10s, 100s, 1000s 1000 = 0.79kgs

Ratings: Rated Voltage: Packing: Weight:

Performance Data
Ratin g 125m A 150m A 160m A 187m A 200m A 250m A 300m A 315m A 375m A 400m A 500m A 600m A 630m A 750m A 800m A 1. 0A 1. 2A 1. 25A 1. 5A 1. 6A 2. 0A 2. 5A 3. 0A 4. 0A 200A/250V ac 10kA/125V p.f. = 1 100A/250V ac 10kA/125V ac p.f. = 0.7 - 0.8 35A/250V ac 10kA/125V ac p.f. = 0.7 - 0.8 Breakin g Capacity M ax mV @ In 1600 1300 1300 1200 1100 900 760 700 660 580 540 400 400 400 330 300 330 250 250 220 190 190 170 160 Min . P reMax. P ower arcin g I2t Loss (W) @ 10I n @ In ( A 2s ) 0.20 0.20 0.21 0.22 0.22 0.23 0.23 0.22 0.25 0.23 0.27 0.24 0.25 0.30 0.26 0.30 0.40 0.31 0.38 0.35 0.38 0.48 0.51 0.64 0.078 0.11 0.17 0.31 0.36 0.56 0.93 0.94 1.2 1.2 2.2 4.6 7.1 8.4 9.6 14 17 14 27 30 68 113 153 224 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

34

Application Engineers +44 (0)1509 882766 or 882760

5 x 20mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

35

6.3 x 32mm Fuses TDC10


Designed to British Standard BS2950A Breaking Capacity:

Bussmann

10 times rated current @ rated voltage


Rating 50mA Rated Voltage V ac Rating 2A 3A 1000 5A 7A 10A 750 500 350 250 12A 15A 20A 25A 32 150 100 250 Rated Voltage V ac

Order Code: Type: Size: Construction:

TDC10 + -Rating Fast Acting 6.3 x 32mm Glass Tube, electroplated brass end caps 50mA to 25A Bulk quantities only

60mA 100mA 150mA 250mA 500mA 750mA 1A 1.5A

Ratings: Packing:

C387
Ordering Code: C387 + Rating Type: Construction: Fast Acting Glass Tube with electro-plated brass end caps 50mA to 25A 50mA to 6.3A - 250V 8A & 10A 100V 12A - 25A 32V

Dimensions (mm):

Ratings: Rated Voltage:

Performance Data:
Rated Current Total Operating Time M in 1000 hours In M ax M in 2.0In M ax 10 seconds

Breaking Capacity: 10In at rated voltage or 63A whichever is greater Available Ratings
Rating 50mA 63mA 80mA 100mA 125mA 160mA 200mA 250mA 315mA 400mA 250 Rated Voltage V ac Rating 500mA 630mA 800mA 1A 1.25A 1.6A 2A 2.5A 3.15A 4A
Application Engineers +44 (0)1509 882766 or 882760

Rated Voltage V ac

Rating 5A 6.3A 8A 10A

Rated Voltage V ac 250

100

250

12A 15A 16A 20A 25A 32

36

6.3 x 32mm Fuses

Bussmann

Time current characteristics

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

37

6.3 x 32mm Fuses AGC and AGC-V (Axial Leads)


Agency Approvals: Designed to UL 248-14 specifications. Dimensions (mm):

Bussmann

Order Code: Type: Construction:

Packing Code + AGC + Rating Fast Acting Glass tube, electroplated brass end caps 50mA to 30A 50mA to 10A - 250V ac 15A to 30A - 32V ac 5s and 100s

Packing Codes:
1. 2. 3. 4. 5. 6.

BK/ bulk pack in 100s; blank - packed in standard 5s.

Notes on Performance Data in the table below.


Breaking capacity 0.7 - 0.8 power factor on AC Voltage drop was measured at 25 deg. C 3 deg. C ambient temperature. I2t was measured at listed breaking capacity and rated voltage. Breaking capacity for AGC 2 to 10A @ 125V is 10,000A. Breaking capacity listed corresponds to maximum rated voltage. Other available ratings - 2mA, 5mA, 10mA, 20mA, 31.25mA, 150mA, 175mA, 333.3mA 400mA, 600mA, 800mA, 1.2A, 1.3A, 1.6A, 1.75A, 1.8A, 3.2A, 4.5A, 6.25A, 7.5A, 12A, 14A. 1 to 10A UL recognised for 125V DC and 500A breaking capacity. Other DC ratings are self certified.

Ratings: Rated Voltage: Packing:

Performance Data
Rated Cu rren t 50m A 63m A 100m A 125m A 190m A 200m A 250m A 300m A 375m A 450m A 500m A 750m A 1A 1. 25A 1. 5A 2A 2. 25A 2. 5A 3A 4A 5A 6A 7A 8A 9A 10A 15A 20A 25A 30A

Rated Breakin g P re-arcin g Voltage Capacity 1 I2t (A2 sec)3 (V) ac (max) ac ac 2.6 x 10 - 4 2.4 x 10 - 4 5.5 x 10 - 4 .003 .008 .011 35A .015 .044 .091 .12 .28 .82 1.5 250V 1.95 3.44 5.4 100A 6.0 5.3 12 25 7 10 200A 13 24 211 240 577 1241 32V 1000A 2276 3812

Ty pical O peratin g 3 Ty pical Voltage D rop2 Volts at 2 t ( A 2 s ec ) I Rated Cu rren t ac 6.5 x 10 - 4 0.67 3.4 x 10 - 4 10.41 1.01 x 10 - 3 6.0 .69 4.67 .84 4.12 .74 4.51 .38 0.89 1.57 2.88 2.59 4.59 2.78 2.67 2.75 0.59 3.69 0.37 5.21 0.31 11 0.35 16 0.27 22 0.28 19 0.26 19 0.31 27 0.25 75 0.22 40 0.23 60 0.23 68 0.23 104 0.19 238 0.18 315 0.20 691 0.14 1450 0.12 2588 0.11 4098 0.12

Agen cy Approvals

6 8 6 8 8 8 6 8 8 6 6 6 8 6 8 8 6 8 8 8 8 6 8 6 6 8 6 6 6 6

6 6 6 6 6 6 6 6 6 6 6 6 8 6 8 8 6 8 8 8 8 6 6 6 6 6 6 6 6 6

38

Application Engineers +44 (0)1509 882766 or 882760

6.3 x 32mm Fuses

Bussmann

ABC and ABC-V (Axial Leads)


Agency Approvals: Design Specification to UL248-14 Dimensions (mm):

Order Code: Type: Construction:

Packing Code + ABC + Rating Fast Acting Ceramic body, electro-plated brass end caps 250mA to 30A 250mA to 20A - 250V; 25 & 30A - 125V ac 5s and 100s

Notes on Performance Data in the table below.


1. 2. 3. 4. 5. 6. Breaking capacity was measured at 0.7 - 0.8 power factor on AC. Voltage drop was measured at 25 deg. C 3 deg. C ambient temperature at rated current. I2t was measured at listed breaking capacity and rated voltage. Breaking capacity for ABC 250mA to 15A @ 125V is 10,000A. Breaking capacity listed corresponds to maximum rated voltage. Other available ratings - 62.5mA, 100mA, 125mA, 375mA, 1.25A, 9A and 12A DC ratings are self certified.

Ratings: Voltage: Packing:

Performance Data
Rated Cu rren t 250m A 500m A 750m A 1A 1. 5A 2A 2. 5A 3A 4A 5A 6A 7A 8A 10A 15A 20A 25A 30A Rated Breakin g P re-arcin g Voltage Capacity 1 I2t (A2 sec) (V) ac (max) ac ac .02 .26 35A .60 1.47 2.8 4.98 100A 8.56 12.3 250V 30.63 19.53 25.52 200A 65.23 115.2 209.6 750A 484.3 400A 497.0 830.0 125V 1000A 1220.0 Ty pical Ty pical O peratin g 3 Voltage D rop2 2 t ( A 2 s ec ) I Volts at Rated Cu rren t ac 1.42 3.25 1.45 0.51 2.31 0.42 3.27 0.35 13 0.35 16 0.25 20 0.26 27 0.25 76 0.25 46 0.23 56 0.24 113 0.20 168 0.17 293 0.15 515 0.12 616 0.13 1078 0.12 1438 0.14 Agen cy Approvals

6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

39

6.3 x 32mm Fuses FWH High Speed Fuse Link for the Protection of Semiconductor Devices
Agency Approvals: Designed to UL standard 248-14 Dimensions (mm):

Bussmann

Order Code: Type: Construction:

FWH-+Rating+A6F Fast Acting Semiconductor Fuse Ceramic Tube, electro-plated brass end caps 250mA to 30A 500V ac 10s

Breaking Capacity at rated voltage: 250mA to 20A - 50kA at pf 0.2 25A to 30A - 20kA at pf 0.2

Ratings: Rated Voltage: Packing:

Performance Data
P art Nu mber F WH-. 250A6F F WH-. 500A6F F WH-001A6F F WH-002A6F F WH-3. 15A6F F WH-005A6F F WH-6. 3A6F F WH-007A6F F WH-010A6F F WH-12. 5A6F F WH-015A6F F WH-016A6F F WH-020A6F F WH-025A6F F WH-030A6F Cu rren t Ratin g 250mA 500mA 1A 2A 3.15A 5A 6.3A 7A 10A 12.5A 15A 16A 20A 25A 30A O peratin g P re-arcin g 2 I t @ 500V 2t ( A 2s ) I ( A 2s ) 0.01 0.05 0.05 0.25 0.4 2 1.3 3.5 3.1 7.7 15 40 36 90 50 125 TBA TBA 20 TBA 44 146 48 177 75 259 TBA TBA TBA TBA P ower Loss @ Rated Cu rren t (W ) 2.7 1.2 1.7 3.2 2.9 2.1 2.3 2.5 TBA 3.53 3.08 4.48 4.26 TBA TBA

40

Application Engineers +44 (0)1509 882766 or 882760

6.3 x 32mm Fuses

Bussmann

GBB and GBB-V (Axial Leads)


Agency Approvals: Designed to UL 248-14 Dimensions (mm):

Order Code: Type: Size: Construction:

Packing Code + GBB + Rating Very Fast Acting 6.3 x 32mm Ceramic Tube, electro-plated end caps 1, 1.25, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 15, 20, 25, 30 250V ac; 125V dc 5s & 100s (BK/) HTB, HFB and Series 8000 fuse blocks

Ratings (A):

Rated Voltage: Packing: Fuse Holders:

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

41

6.3 x 32mm Fuses MDL and MDL-V (Axial Leads)


Agency Approvals: Design Standard UL248-14 Dimensions (mm):

Bussmann

Order Code: Type: Size: Construction: Ratings: Rated Voltage: Packing:

Packing Code + MDL + Rating Time Delay 6.3 x 32mm Glass Tube, electroplated end caps 63mA to 30A 63mA to 8A - 250V ac 9A to 30A - 32V ac 5s and 10s Notes on Characteristic figures in the table below.
1. 2. 3. 4. 5. 6. Breaking capacity was measured at 0.7 - 0.8 power factor on AC. Voltage drop was measured at 25 deg. C 3 deg. C ambient temperature at rated current. I2t was measured at listed breaking capacity and rated voltage. Breaking capacity for MDL 62.5mA to 8A @ 125V ac is 10,000A. Breaking capacity listed corresponds to maximum rated voltage. Other available ratings - 10mA, 31.25mA, 150mA, 175mA, 400mA, 600mA, 700mA, 800mA 1.2A, 1.6A, 1.8A, 2.8A, 3.2A, 3.5A, 6.25A, 7.5A, 12A. 1 to 10A UL recognised for 125V DC and 500A breaking capacity. Other DC ratings are self certified.

Performance Data
Rated Cu rren t 63m A 100m A 125m A 190m A 200m A 250m A 300m A 375m A 500m A 750m A 1A 1. 25A 1. 5A 2A 2. 25A 2. 5A 3A 4A 5A 6A 7A 8A 9A 10A 15A 20A 25A 30A Rated Voltage (V) ac (max) Breakin g Capacity 1 ac P re-arcin g Ty pical I 2t O peratin g 3 ( A 2 s ec ) I 2 t ( A 2 s ec ) ac .21 .04 .05 .08 .08 .43 .41 .72 1.48 3.75 10 11 19 68 55 63 43 181 311 368 457 280 568 671 1931 5652 15356 28033 ac .51 .11 .06 .52 .68 .96 1.13 1.86 2.52 5.11 12.65 21.40 30.90 79.70 78.20 77.10 68.60 203.50 374.00 427.50 507.60 455.20 685.00 874.00 2296.00 5992.00 15789.00 28499.00 Ty pical Voltage D rop2 Volts at Rated Cu rren t 5.56 2.02 1.68 1.12 1.00 1.02 1.48 0.85 1.26 1.01 0.98 0.77 0.74 0.59 0.27 0.42 0.35 0.20 0.19 0.17 0.15 0.12 0.14 0.12 0.14 0.05 0.07 0.07 Agen cy Approvals

35A

250V

100A

200A

6 8 6 8 8 8 6 8 6 6 8 6 6 6 8 6 8 8 6 8 8 8 6 6 6 6 6 6

6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 6 8 8 8

32V

1000A

42

Application Engineers +44 (0)1509 882766 or 882760

6.3 x 32mm Fuses

Bussmann

MDQ and MDQ-V (Axial Leads)


Agency Approvals: Design Sprecification UL248.14 Dimensions (mm):

Order Code: Packing Code + MDQ + Rating Type: Size: Dual Element, Time Delay 6.3 x 32mm

Construction: Glass tube, electroplated brass end caps Ratings: Rated Voltage: Packing: Fuse Holders: 10mA to 1.6A 10mA to 7A - 250V ac 7.5A to 30A - 32V ac 5s & 100s (BK/) HTB, HB series and series 8000 fuse blocks

Performance Data
Ratin g 10m A 32m A 63m A 100m A 125m A 150m A 175m A 190m A 200m A 250m A 300m A 375m A 400m A 500m A 600m A 750m A 800m A 1A 1. 2A 1. 25A 1. 5A 1. 6A 2 50 V Voltage 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Ratin g 1. 8A 2A 2. 25A 2. 5A 2. 8A 3A 3. 2A 4A 5A 6A 6. 25A 7A 7. 5A 8A 9A 10A 12A 15A 20A 25A 30A 32 V 2 50 V Voltage 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

43

6.3 x 32mm Fuses MDA and MDA-V (Axial Leads)


Agency Approvals: Design Specification UL248-14 Dimensions (mm):

Bussmann

Order Code: Type: Size: Construction:

Packing Code + MDA + Rating Time Delay 6.3 x 32mm Ceramic Tube with electro-plated brass end caps 200mA to 30A 250V ac 5s and 100s (BK/)

Ratings: Rated Voltage: Packing:

Performance Data
Notes on Performance Data.
1. 2. 3. 4. Breaking capacity was measured at 0.7 - 0.8 power factor on AC. Voltage drop was measured at 25 deg. C 3 deg. C ambient temperature at rated current.

Rated Cu rren t

Rated Breakin g Voltage Capacity 1,4 (V) ac (max) ac

P re-arcin g I 2 t ( A 2 s ec ) ac .4 4 .0 5 1. 7 6 5. 1 2 10 24 36 27 35 141 31 0 53 4 591 8 98 8 43 2 38 58 2 1 0 97 1 56 5

5.

6.

200m A 250m A I2t was measured at listed breaking capacity and 500mA rated voltage. 750m A Breaking capacity for MDA 31.25mA to 15A @ 1A 125V ac is 10,000A. Breaking capacity listed 1. 5A corresponds to maximum rated voltage. 2A Other available ratings - 31.25mA, 62.5mA, 100mA, 125mA, 150mA, 300mA, 400mA, 600mA, 2. 5A 3A 800mA, 1.25A, 1.6A, 2.8A, 3.2A, 4.5A, 6.25A, 12A. 4A All DC ratings are self-certified. 5A 6A 7A 8A 10A 15A 20A 25A 30A

3 5A

1 00A 2 50 V 200A

1 50 0 A 400A 1 000A 1 000A

Ty pical O peratin g 3 I 2 t ( A 2 s ec ) ac .8 2 .0 7 2. 5 2 6. 0 8 12 30 73 36 144 16 5 36 8 56 7 36 4 90 6 92 4 3 59 761 1410 206 4

Ty pical Voltage D rop2 Volts at Rated Cu rren t 1. 8 7 3. 1 4 1. 1 5 1. 2 0 0. 6 9 0. 0 7 0. 8 5 0. 3 2 0. 2 2 0. 8 1 0. 7 1 0. 6 1 0. 5 1 0. 3 1 0. 2 1 0. 3 1 0. 3 1 0. 3 1 0. 4 1

A g en c y Approvals

8 8 6 8 6 6 8 6 6 6 8 6 8 8 6 8 8

6 6 6 6 6 6 6 6 6 6 8 6 8 8 6 8

44

Application Engineers +44 (0)1509 882766 or 882760

6.3 x 32mm Fuses

Bussmann

TDC11
Agency Approvals: Breaking Capacity: There are no agency approvals for this fuse. 10 times rated current

Rating 50mA 60mA 100mA 150mA 250mA 500mA 750mA

Rated Voltage V ac

Rating 1A 1.5A

Rated Voltage V ac 350

Order Code: Type: Size: Construction:

TDC11 + Rating Time Delay 6.3 x 32mm Glass Tube, electro plated brass end caps 50mA to 10A 100s & 1000s HTB, HB, HHB, HFB and Series 8000 fuse

1000

2A 3A 5A

250

Ratings: Packing: Fuse Holders:

750 500

7A 10A

150 100

Dimensions (mm):

C436
Order Code: C436 + Rating Type: Size: Time Delay 6.3 x 32mm

Construction: Glass Tube, electro plated brass end caps Ratings: 800mA, 1A, 1.25A, 1.6A, 2A, 2.5A, 3.15A, 4A, 5A, 6.3A 250V ac

Performance Data:
Rated Current Total Operating Time M in 2 In M ax 10 Seconds M in 20 m/seconds 10 In M ax 70 m/seconds

Rated Voltage:

Breaking Capacity:

50A @ rated voltage

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

45

Automotive Fuses ATC


Agency Approvals: Dimensions (mm): 3 to 40A

Bussmann

Ratings and Colour Codes


Order Code: Type: Ratings: Rated Voltage: ATC + Rating Fast Acting 1A to 40A 32V
Rating (A) 1 2 3 4 5 7.5 Colour Code Black Grey Violet Pink Tan Brown Rating (A) 10 15 20 25 30 40 Colour Code Red Blue Yellow Clear Green Amber

ATM
Agency Approvals: Dimensions (mm): 3 to 30A

Ratings and Colour Codes


Order Code: Type: Ratings: Rated Voltage: ATM + Rating Fast Acting 2A to 30A 32V dc
Rating (A) 2 3 4 5 7.5 Colour Code Grey Violet Pink Tan Brown Rating (A) 10 15 20 25 30 Colour Code Red Light Blue Yellow Natural White Green

MAX
Dimensions (mm):

Ratings and Colour Codes


Rating (A) Colour Code Yellow Green Orange Rating (A) 50 60 Colour Code Red Blue

Order Code: Type: Ratings : Rated Voltage:

MAX + Rating Time Delay 20A to 60A 32V dc

20 30 40

46

Application Engineers +44 (0)1509 882766 or 882760

Miscellaneous Fuses

Bussmann

AGA and AGA-V (Axial Leads)


Agency Approvals: UL standard 248-14. Dimensions (mm):

Order Code: Packing Code + AGA + Rating Type: Size: Fast Acting 6.35 x 15.9mm Glass tube, albaloy coated brass end caps

Construction:

Ratings: Rated Voltage: Packing:

63mA to 30A 62.5mA to 1.5A - 125V 2A to 30A - 32V ac 5s and 100s (BK/)

Ratin g 63mA 100mA 125mA 250mA 375mA 500mA 600mA 750mA 1A 1.5A

Rated Voltage 6 6 6 6 6 125V ac 6 6 6 6 6

Ratin g 2A 2. 5 3A 5A 6A 7A 7. 5A 10A 15A 20A 25A 30A

Rated Voltage 6 6 6 6 6 32V ac 6 6 6 6 6 6 6

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

47

Miscellaneous Fuses AGX and AGX-V (Axial Leads)


Agency Approvals: UL standard 248-14 Dimensions (mm):
Order Code: Packing Code + AGX + Rating Type: Size: Fast Acting 6.4 x 25.4mm

Bussmann

Construction: Glass tube, albaloy coated brass end caps Ratings: Packing: 2mA to 30A 5s and 100s (BK/)

Ratin g 2m A 5m A 10m A 32m A 63m A 100m A 125m A 190m A 200m A 250m A 300m A 375m A 400m A 500m A 750m A 1A

Rated Voltage 6 6 6 6 6 6 6 250V ac 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

Ratin g 1. 25A 1. 5A 2A 2. 5A 3A 4A 5A 6A 7A 8A 10A 15A 20A 25A 30A

Rated Voltage 6 250V ac 6 6 6 125V ac 6 6 6 6 6 6 6 32V ac 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

48

Application Engineers +44 (0)1509 882766 or 882760

Miscellaneous Fuses

Bussmann

GLD and GBA


Agency Approvals: Complies with UL standard 248-14 Type GLD has an electro-plated pin for positive electrical signal circuit activation. Type GBA has a red pin for high visibility.
Order Code: GLD or GBA + Rating

Dimensions (mm):

Type: Size:

Fast Acting, pin indicating fuse. 6.3 x 31.8mm

Construction: Fibre tube, electro plated brass end caps Ratings: 500mA, 750mA,1A, 1.5A, 2A, 3A, 4A, 5A, 6A, 10A, 12A, 15A 125V ac

Rated Voltage:

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

49

Miscellaneous Fuses TDC17 (C17)


Agency Approvals: Conforms to BS646 For use in plugs and socket outlet adaptors to BS546 Dimensions (mm): Breaking Capacity:
Order Code: Type: Construction: Ratings (A): Rated Voltage: Packing: TDC17- + Rating Fast Acting, high breaking capacity Ceramic cartridge, silvered end caps 1, 2, 3, 5 250V ac 10s, 100s, 1000s
Rating (A) 1 2 3 5 Colour Code Green Yellow Black Red

Bussmann

5 x 19 1000A at 0.6 lagging power factor - 250V


Max. mV drop @ In 500 300 235 160

TDC180 (C180)
Agency Approvals: The British Standard plug top fuse carries ASTA accreditation for 2 to 13A, all fuses comply with BS1362 and carry the BSI Kite Mark. Dimensions (mm):
Order Code: TDC180 + Rating or C180 + Rating Type: Fast Acting Construction: Ceramic cartridge, silvered end caps Ratings (A): 1, 2, 3, 5, 7, 10, 13 Rated Voltage: Packing: 240V ac 10s, 100s and 1000s

6.4 x 25.4 6000A/250V @ 0.3 - 0.4 p.f.


Colour Code Black Black Brown

Breaking Capacity:
Rating (A) 1 2 3 5 Colour Code Black Black Red Black

Rating (A) 7 10 13

50

Application Engineers +44 (0)1509 882766 or 882760

Fuse Clips for 5mm dia. Fuses

Bussmann

HTC-200M
For 5mm diameter fuses, tape and fanfold packed. Contacts - tin plated bronze. Ammo packed 1000s Dimensions (mm)

Dimensions (mm)

PC Board mounted fuse clips with end stops, for 5mm fuses.

HTC-210M

Fuse Clips with end stops and straight leads.


C a t l g ue ao N um b e r 1 A 3 3 99-0 1 1 A 3 3 99-0 4 1 A 3 3 99-1 0 C lp M a t ra l i e i * Fi i h ns

1A3399

Dimensions (mm)

B e r li m C oppe r S ive r y lu l B e r li m C oppe r B rg htT i y lu i n S prng B r nze i o B rg htT i i n

* Beryllium Copper recommended for currents higher than 15 amps.

High Profile
Catalogue Number 1A5018-7 1A5018-10 Clip Material* Spring Bronze Spring Bronze Finish Silver Bright Tin

Dimensions (mm)

Fuse Clips with end stops and straight leads.

1A5018

* Beryllium Copper recommended for currents higher than 15 amps.

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

51

Fuse Clips for 5mm dia. Fuses 1A5601


Fuse Clips for currents up to 7A. Dimensions (mm)
Catalogue Number 1A5601

Bussmann

Clip Material Brass

Finish Bright Tin

1A5602

Fuse Clips for currents up to 7A.

Catalogue Number 1A5602

Clip Material Brass

Finish Bright Tin

Dimensions (mm)

52

Application Engineers +44 (0)1509 882766 or 882760

Fuse Clips for 6.3mm dia. Fuses

Bussmann

1A3398
Fuse Clips without end stops, with straight leads.

Catalogue Number 1A3398-07

Clip Material* Spring Bronze

Finish Bright Tin

* Beryllium Copper recommended for currents higher than 15A.

Dimensions (mm) Dimensions (mm)

Fuse Clips without end stops, with angled out leads.


Catalogue Number 1A4533-01 1A4533-06 Clip Material* Beryllium Copper Spring Bronze Finish Bright Tin Bright Tin

1A4533

* Beryllium Copper recommended for currents higher than 15A.

Catalogue Number 1A1907-03 1A1907-02 1A1907-05 1A1907-06

Clip Material* Beryllium Copper Spring Bronze Beryllium Copper Spring Bronze

Finish Bright Tin None/Bright Dipped Silver Bright Tin

Fuse Clips with end stops and straight leads.

1A1907

* Beryllium Copper recommended for currents higher than 15A.

Dimensions (mm)

Fuse Clips with end stops and angled-in leads.


Catalogue Number 1A1119-04 1A1119-05 1A1119-10 Clip Material* Beryllium Copper Beryllium Copper Spring Bronze Finish Bright Tin Silver Bright Tin

1A1119

Dimensions (mm)

* Beryllium Copper recommended for currents higher than 15A.

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

53

Fuse Clips for 6.3mm dia. Fuses 1A4534


Fuse Clips with end stops and angled-out leads. For 6.3mm dia. fuses.

Bussmann

Catalogue Number 1A4534-01 1A4534-06

Clip Material* Beryllium Copper Spring Bronze

Finish Bright Tin Bright Tin

Dimensions (mm)

* Beryllium Copper recommended for currents higher than 15A.

1A1120

Fuse Clips without end stops, angled-in leads. For 6.3mm dia. fuses.
Catalogue Number 1A1120-02 1A1120-05 1A1120-06 1A1120-09

Dimensions (mm)

Clip Material* Spring Bronze Beryllium Copper Beryllium Copper Spring Bronze

Finish None/ Bright Dipped Silver Bright Tin Bright Tin

* Beryllium Copper recommended for currents higher than 15A.

54

Application Engineers +44 (0)1509 882766 or 882760

Fuse Clips Miscellaneous Sizes

Bussmann

Fuse clips with mounting holes for 6.35mm dia. fuses. All dimensions in mm
Catalogue Reference 5681-01 5681-08 5681-15 5682-01 5682-02 5682-11 5682-41 5682-44 Yes No End Stop Clip Material BeCu Spg. Br. Spg. Br. BeCu BeCu BeCu Spg. Br. Spg. Br. Finish Silver Nickel Bright Tin Silver Silver Bright Tin Bright Tin Bright Tin 3.3 6.6 10.4 8.13 3.35 1 3.56 6.73 10.4 8.13 3.35 2 B (to end stop) C (contact) D (Height) E (Width) Hole Dia. Fig. Ref.

5681 and 5682


Figure 1

3.56 3.3

Notes BeCu = Beryllium Copper Spg. Br. = Spring Bronze

5956 and 5960


Fuse clips with mounting holes for 10.3mm fuses. Figure 2
Finish Bright Tin Silver Silver Albaloy Nickel Bright Dip Bright Dip Bright Tin Bright Tin Bright Tin Bright Tin B (to end stop) 4.3 5.08 4.3 5.08 4.3 5.08 4.3 4.3 5.08 5.08 9.72 18.0 11.9 C (contact) 7.8 D (Height) 18.0 E (Width) 11.9 Hole Dia. 4.4 5.0 4.4 5.0 5.0 5.0 4.4 5.0 3.4 4.4 3.25 1 Fig. Ref. 2

All dimensions in mm
Catalogue Reference 5956-16 5960-07 5960-09 5960-23 5960-44 5960-51 5960-53 5960-61 5960-62 5960-63 5960-64
Notes BeCu = Beryllium Copper Spg. Br. = Spring Bronze

End Stop No

Clip Material Spg. Br. BeCu BeCu BeCu Spg. Br.

Yes

Spg. Br. Spg. Br. Spg. Br. Spg. Br. Spg. Br. Spg. Br.

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

55

Fuse Clips Automotive 1A5600


Fuse clips for ATC Fuses (0 - 20A).

Bussmann
Dimensions (mm)

Catalogue Number 1A5600

Clip Material Brass

Finish Satin Finish Tin

1A5778

PCB fuse clip for ATM fuse, made from nickel plated brass. Packed and sold in 1000s only.

Dimensions (mm)

1A5779

Fuse clip for ATM automotive fuse, made from nickel plated brass, base material glass filled nylon. Current rating 15A, voltage 500V ac. Dimensions (mm)

1A5780

Fuse clip for ATC automotive fuses, made of nickel plated brass with glassed filled nylon base. Current rating 15A, voltage 500V ac. Dimensions (mm)

56

Application Engineers +44 (0)1509 882766 or 882760

Fuse Holders
HTC-45M - PCB Vertical Mount for 5 x 20mm fuses HTC-50M - PCB Horizontal Mount for 5 x 20mm fuses
Dimensions (mm):

Bussmann

HTC Series

HTC-45M

HTC-50M

Specification: Terminals: Moulded Materials: Solderability: Electrical:

250V ac, 6.3A, 2.5W, Bayonet Cap/Carrier. Tin Plated High temperature thermoplastic that meets the flammability ratings of UL 94VO; glow wire test at 960 degrees C per IEC 695-2-1. In accordance with IEC 68-2-20 Contact resistance - 10m Insulation resistance - 10M Dielectric strength - 2000V PC2 (fuse holders) UL recognised, CSA Certified, Semko. Standard quantity - 10 (no prefix); Bulk quantity - 100 (prefix catalogue number BK).

Shock Safety: Agency Approvals: Packaging:

HTC-60M, HTC-65M for 5 x 20mm fuse links


PC Board mount, 250V ac 6.3A Dimensions (mm)

Order Code:

HTC-15M, HTC-140M, HTC-150M for 5 x 20mm fuse links


PCB Fuse block and snap-on cover Dimensions (mm)

HTC-60M (2 legs) HTC-65M (4 legs) 6.3 250V ac 10s, 100s HTC-15M, HTC-140M and HTC-150M PCB Fuse block & snap-on cover. 6.3 250V ac 10s, 100s

Rating (A): Rated Voltage: Packing: Order Code: Type: Rating (A):

Further details of all these products can be found on Data sheet number 2110 available from our Application Engineers

Rated Voltage: Packing:

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

57

Fuse Holders HTC Series


Specifications: Terminals : Moulded Materials : for 5 x 20mm fuse links Brass, tin plated

Bussmann

High temperature thermoplastic that meets the flammability rating of UL94VO; glow wire test 960 degrees Centigrade per IEC 695-2-1. in accordance with IEC 68-2-20 (SEMKO not HTC30) Contact Resistance - 10m; Insulation Resistance - 10M; Dielectric Strength - 2000V 250V ac PC2 (fuse holders). Standard quantity 10 (no prefix), Bulk quantity 100 (prefix BK in catalogue number).

Order Code: Type: Ratings:

HTC-30M Screwdriver Slot 6.3A, 2.5W

Solderability: Agency Approvals: Electrical:

Rated Voltage: Shock Safety:


Order Code: Type: Ratings: HTC-35M Threaded Cap 6.3A, 2.5W

Packaging: Dimensions (mm)

HTC-30M

Order Code: Type: Ratings:

HTC-40M Screwdriver Slot 6.3A, 2.5W

HTC-35M

HTC-40M
Order Code: Type: Ratings: HTC-55M Bayonet Cap/Carrier 6.3A, 2.5W

HTC-55M

Order Code: Type: Ratings:

HTC-70M Bayonet Cap/Carrier 10A, 2.5W

HTC-70M

58

Application Engineers +44 (0)1509 882766 or 882760

Fuse Holders
Horizontal Mount HBH-I for 6.35 x 31.75mm fuses Horizontal Mount HBH-M for 5 x 20mm fuses Agency Approvals: Dimensions(mm):

Bussmann

HBH-I and HBH-M

HBV
Vertical Mount with Stability Pins
HBV-I for 6.35 x 31.75mm fuses, HBV-M for 5 x 20mm fuses Agency Approvals: Stability pins are integral to the holder body giving additional stability to holders for wave soldering, reducing stress on the contact pins. Dimensions(mm):

HBW
Vertical Mount without Stability Pins
HBW-I for 6.35 x 31.75mm fuse, HBW-M for 5 x 20mm fuse Agency Approvals: Dimensions (mm):

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

59

Fuse Holders HKP Series for 6.35 x 31.2 fuse links


Agency Approvals: Order Codes:

Bussmann

HKP - standard fuse holder HKP-L - with 2250V stand-off barrier HKP-W - with drip proof knob. HKP-CC - with .094mm shorter body (not shown)

Dimensions (mm):
Order Code: HKP HKP-L, HKP-W, , HKP-CC Type: Rating: Rated Voltage: Packing: Standard Fuse Holders 30A 250V ac 100s

Agency Approvals: Order Codes: HKP-BBHH - standard fuse holder with 6.35mm quick connects, nut and washer assembly. HKP-HH - standard fuse holder with 6.35mm quick connect. HKP-LW-HH - standard fuse holder with drip proof knob, 2250V stand-off barrier and quick connects.

Order Code: HKP-BBHH, HKP-HH, HKP-LW-HH Type: Rating: Rated Voltage: Packing: Fuse Holders with 6.35mm quick connects 15A 250V ac 100s

Dimensions (mm):

Agency Approvals: Order Code: Dimensions(mm): HPK-OO - standard fuse holder with snap lock.

Order Code: HKP-OO Type: Rating: Rated Voltage: Packing: Snap-lock fuse holder 30A 250V ac 100s

60

Application Engineers +44 (0)1509 882766 or 882760

Fuse Holders
Agency Approvals: For 6.35 x 31.2mm and 5 x 20mm fuse links Electrical Data: Insulation resistance to IEC257, 10,000 ohms @ 500V dc; contact resistance to IEC257, 0.005 ohms maximum @ 1A; stand-off voltage as IEC257, 480V mil @ 3.175mm thickness. Mounting: Maximum thickness of mounting panel 7.62mm See over the page for order code information.
Terminal Options Common dimensional data: length (finger grip) - 42.9mm plus in-line terminal (screwdriver slotted) 44.5mm Max. Panel Thickness Solder/4.8mm Quick Connect In-line Right Angle 6.35 Quick Connect Right Angle

Bussmann

HTB Series

Finger Grip Carrier

Carrier Options

6.35 x 31.75 Finger Grip Screwdriver

5 x 20 Finger Grip Screwdriver

In-line

HTB-22I HTB-24I HTB-26I HTB-28I K N O B T Y P E C A R R I E R 7.62 HTB-22M HTB-24M HTB-26M HTB-38M HTB-42I HTB-44I HTB-46I HTB-48I 3.175 HTB-42M HTB-44M HTB-46M HTB-48M HTB-62I HTB-64I HTB-66I HTB-68I 7.62 HTB-62M HTB-64M HTB-66M HTB-68M HTB-82I HTB-84I HTB-86I HTB-88I 3.175 HTB-82M HTB-84M HTB-86M HTB-88M S C R E W D R I V E R S L O T HTB-32I HTB-34I HTB-36I HTB-38I 7.62 HTB-32M HTB-34M HTB-36M HTB-38M HTB-52I HTB-54I HTB-56I HTB-58I 3.175 HTB-52M HTB-54M HTB-56M HTB-58M HTB-92I HTB-94I HTB-96I HTB-98I 3.175 HTB-92M HTB-94M HTB-96M HTB-98M

[ \ [ \ [ \ [ \ \ \ \ \ \ \

\ \ \ \ \ \ \ \ [ \ [ \ [ \

\ [ \ [ \ [ \ [ \ \ \ \ \ \

\ \ \ \ \ \ \ \ \ [ \ [ \ [

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

61

Fuse Holders HTB Series


Fuse carriers can be order separately BK/ = Bulk Packed. FT = Knob type for 20, 40, 60 and 80 series.

Bussmann

ST = Screwdriver slotted for 30, 50 and 90 series only. I = 6.35 x 31.75mm M = 5 x 20mm
Screwdriver Slotted Carrier

62

Application Engineers +44 (0)1509 882766 or 882760

Fuse Holders In-Line


Universal In-Line Fuse Holder for 6.35 x 22.2, 25.4 and 31.75mm, fuses supplied without leads as standard. Variations Holder with pre-attached lead wires Wire Colour Yellow Red Black 482.6mm length BK/HHB-Y419 BK/HHB-R419 BK/HHB-B419 203.2mm length BK/HHB-Y408 BK/HHB-R408 BK/HHB-B408

Bussmann

HHB

Order Code: Material: Rating: Rated Voltage: Packing:

HHB or BK/HHB Body - nylon, contact plated copper 32A 30V ac Standard pack - 10s Bulk Pack (BK/)100s

Dimensions (mm):

L = 53.34 max with 22.2mm fuse fitted L = 57.15 max with 25.4mm fuse fitted L = 61.50 max with 31.75mm fuse fitted

HFB
Waterproof In-Line Fuse Holder for 6.35 x 31.75mm fuses. Suitable for outdoor use in harsh environments. Material will withstand many organic solvents. Dimensions (mm):

Order Code: Material:

HFB Body - Thermoplastic rubber, contacts plated copper 30A 32V ac Standard - 10s Bulk (BK/) - 20s

Rating: Rated Voltage: Packing:

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

63

Fuse Holders In-Line Automotive HHC and HHD


Types Available:

Bussmann

HHC = Yellow fuse holder, to take 3 - 20A fuse, supplied with 1.31mm2 black wire HHD = Black fuse holder, to take 3 - 30A fuse, supplied with 3.31mm2 yellow wire HHD-C = Cover for both of the above fuse holders. Dimensions:
Order Code: Type: HHC or HHD In-line fuse holders for ATC blade type fuses 3A to 30A 32V dc

Rating: Rated Voltage:

HHL and HHM


Types Available: HHL = Fuse holder with cover for 2 - 20A fuses, supplied with 1.31mm2 101.6mm length of wire. HHM = Fuse holder with cover for 2 - 30A fuses, supplied with 3.31mm2 101.6mm length of wire.
Order Code: Type: Rating: Rated Voltage: HHL or HHM In-line fuse holder for MINI fuses 30A 32V dc

Bodies and covers can be ordered separately.

HHX
Types Available: HHX = Fuse holder with cover for 20 - 60A fuses, supplied with 13.3mm2, 127mm long lead wire. Bodies and covers can be supplied separately
Order Code: Type: Rating: Rated Voltage: HHX In-line fuse holder for MAXI fuses 60A 32V dc

64

Application Engineers +44 (0)1509 882766 or 882760

Fuse Blocks
Agency Approvals: Fuse blocks for mounting 6.35 x 31.75 fuses, available in screw mount or snap-in mount format. Can be used as single pole or ganged up to 12 pole. Type Variations for Bolt-in Mounting.
Part Number S-8001 S-8002 S-8101 S-8102 S-8201 S-8202 S-8203 S-8301 8300 8200 Series 8000 8100 Terminal Solder 4.76mm Quick Connect 6.35mm Quick Connect Screw Angle in degrees 0 40 0 40 0 40 Side 1 to 12 Poles (suffix)

Bussmann

8000 Series

Order Code: Packing Code + S + Item Code + Number of Poles Rating: Rated Voltage: Packing: Up to 30A max. depending on type of terminals 300V ac 10s, 100s & 1000s (BK/)

Type variations for Snap-in Mounting.


Part Number S-8001-1-SNP S-8002-1-SNP S-8101-1-SNP S-8102-1-SNP S-8201-1-SNP S-8202-1-SNP Series 8000 8100 8200 Terminal Solder 4.76mm Quick Connect 6.35mm Quick Connect Angle in degrees 0 40 0 40 0 Side

Dimensions (mm)

www.bussmann.com

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

65

Fuse Blocks 4405 and 4406

Bussmann
Fuse block for 6.35 x 31.75mm fuses. The base width is 12.7mm. Reference 4405 has parallel solder terminals and reference 4406 has side solder terminals (at right angles to the base). Dimensions (mm):

Order Code: Rating: Rated Voltage:

4405 or 4406 30A 250V ac

4406

2499
Agency Approvals:

4405

Fuse block for 6.35 x 31.75mm fuses with side quick-connect 6.35mm terminals. Dimensions (mm):
Order Code: Rating: Rated Voltage: 2499 15A 250V ac

Spare fuse blocks to hold spare fuses, which can be screwed to your base, are available (without any terminals) under order reference 4574.

3828 Series

Fuse block for 6.35 x 25.4mm fuses with parallel solder terminals. Available from 1 pole to 12 pole, order code 3828 + number of poles. Base width is 12.7mm. Dimensions (mm):

4520 and 4393

Single Pole Fuse Block for 6.35 x 25.4mm fuses. Width of base 12.7mm with parallel solder terminals. A spare fuse block for holding spare fuses, mountable on your base, is available, order code 4393. Dimensions (mm):

Order Code: Rating: Rated Voltage:

4520 or 4393 for spare fuse block 30A 250V ac

4520

4393

66

Application Engineers +44 (0)1509 882766 or 882760

Fuse Technology and Glossary of Terms


Basic Fuse Technology
Miniature fuses serve two main purposes: a. To protect components, equipment and people from risk of fire and shock risk caused by overcurrents. To isolate sub systems from the main system once a fault has occurred. greater than or equal to the circuit voltage. Because the fuse has such low resistance, the voltage rating becomes critical only when the fuse is trying to open. The fuse must be able to open quickly, extinguish the arc after the fuse element has melted and prevent the system open-circuit voltage from re-striking across the open fuse element.

Bussmann
Glossary of Terms

b.

Overcurrents
Overcurrents exist when the normal load for a circuit is exceeded. It can be either an overload or short circuit. An overload is any current flowing within the normal circuit path that is higher than the normal circuit full load current. A short circuit is an overcurrent which greatly exceeds the normal full load current of the circuit. Components and equipment can be damaged by both types of overcurrents.

Current Ratings
Each fuse is marked with a nominal current rating. Several factors can affect the ability of the fuse to carry this rated current. First the base material of the clip in which the fuse is mounted may greatly affect the performance of the fuse. Another important factor is the conductor size used to connect the fuse to other circuit components. If the conductor is too small, it will generate heat. That extra heat will be seen by the fuse, causing the fuse to open before it should. It is also important that the fuse be installed with clean and tight connections. If the connections are dirty or loose, they will cause increased resistance, generating extra heat. That heat will lead to a shortened fuse life.

Selecting Overcurrent Protection


During normal load current conditions, the fuse must carry the normal load current of the circuit without nuisance opening. However, when an overcurrent occurs the fuse must interrupt the overcurrent and withstand the voltage across the fuse after arcing. To properly select a fuse the following items must be considered:

Breaking Capacity
A fuse must be able to open the circuit under a short circuit without endangering its surroundings. The breaking capacity of a protective device is the maximum available current, at the rated voltage, that the device can safely open without the possibility of rupturing.

Voltage rating (ac or dc voltage) Full load currents (RMS Amperes) Available short circuit current In-rush characteristics Characteristics of equipment or components to be protected Ambient conditions Standards requirements

Fuse Resistance
In most applications, the voltage drop across the fuse due to its internal and contact resistances is negligible. There are, however, certain critical applications where the fuse resistance must be considered and it is important that the circuit designer understands the fuse characteristics in order to select the proper fuse.

In addition, consideration must be given to: Available board space Type of mounting Automatic or manual insertion Reliability Ease of field service.

Physical Sizes
There are numerous physical sizes of electronic fuses, including subminiature fuses. The most common cylindrical designs are 5x20mm and 6.3x32mm. Subminiature fuses are often used when board space is limited. For applications of this type there are both through-hole and surface mount devices available. Standard package sizes for surface mount fuses are 1608, 3216 & 6125. These sizes are standard throughout the electronic industry. Through-hole axial and radial leaded products allow fuses to be PCB mounted. Standard 5x15mm & 5x20mm fuses fitted with leads can also be mounted in this way. Our surface mount range will continue to be expanded allowing them to be designed into an even wider range of applications.

Electronic circuits frequently exhibit surges, caused by capacitors charging, motors being momentarily stalled, or high voltage components sparking over. It is important that designers take account of these temporary conditions during fuse selection. The ability to resist surges is a function of the fuse design relative to the surge pulse, duration, frequency etc. Comparison of a manufacturers I2t value alone is not sufficient and Bussmann would be pleased to advise on specific applications.

Voltage Ratings
The voltage rating of the fuse must be www.bussmann.com

Ampere squared seconds I2t A measure of heat energy supplied to a circuit while the fuse is clearing a fault. It can be expressed as melting I2t, arcing I2t or the sum of them clearing I2t. This is usually used as a measure of short circuit performance. Arcing time The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared. Clearing time The total time between the beginning of the overcurrent and the final opening of the circuit at rated voltage by an overcurrent protective device. Clearing time is the total of the melting time and the arcing time. Fast acting fuse A fuse which opens on overload and short circuits very quickly. This type of fuse is not designed to withstand temporary overload currents with some electrical loads. Fuse An overcurrent protective device with a fusible link that operates and opens the circuit on an overcurrent condition. Overcurrent A condition which exists on an electrical circuit when the normal load current is exceeded. Overcurrents take on two separate characteristics - overloads and short circuits. Overload Can be classified as an overcurrent which exceeds the normal full load current of a circuit. Resistive load An electrical load which is characterised by not having any significant inrush current. When a resistive load is energised, the current rises instantly to its steady state value, without first rising to a higher value. RMS Current The R.M.S. (root mean square) value of any periodic current is equal to the value of the direct current which, flowing through a resistance, produces the same heating effect in the resistance as the periodic current does. Short circuit Can be classified as an overcurrent which exceeds the normal full load current of a circuit by a factor many times (tens, hundreds or thousands greater). Time delay fuse A fuse with a built-in time delay that allows temporary and harmless inrush current to pass without operating, but is so designed to open on sustained overloads and short circuits. Time lag (surge proof) A fuse which can withstand short high current pulses and is particularly suitable for television sets, amplifiers etc. Voltage rating A maximum open circuit voltage in which a fuse can be used, yet safely interrupt an over-current. Exceeding the voltage rating of a fuse impairs its ability to clear an overload or short circuit safely.

e-mail: sales@bussmann.co.uk

Sales Fax: +44 (0)1509 882788

67

Parts Index
1608FF 1A1119 1A1120 1A1907 1A3398 1A3399 1A3400 1A4533 1A4534 1A5018 1A5600 1A5601 1A5602 1A5778 1A5779 1A5780 2499 3216LV/3216CP/3216FF 3828 Series 4393 4405 4406 4520 5681 5682 5956 5960 6125T 8000 Series 3 53 54 53 53 51 54 53 54 51 54 52 52 56 56 56 66 4 66 66 66 66 66 55 55 55 55 6 65 GDC GDC-V GLD GMA GMA-V GMC GMC-V GMD GMD-V 22, 26 22, 26 49 30 30 32 32 34 34

Bussmann
Product Approval Marks
ASTA - Association of Short Circuit Testing Authorities (UK).

H
HBH-I HBH-M HBV HBW HFB HHB HHC HHD HHL HHM HHX HKP Series HTB Series HTC Series 59 59 59 59 63 63 64 64 64 64 64 60 61
57 57 57 58 58 58 57 57 58 57 57 58

BSI - British Standards Institute (UK). CSA - Canadian Standards Association (Canada) CSA - Component Acceptance Mark (Canada) IMQ - Istituto del Marchio di Qualita (Italy) MITI - Ministry Industrial Testing Institute (Japan). SEMKO - Svenska Elektriske Materielkontrollanstalten (Sweden) UL - Underwriters Listed (USA). Underwriters Recognised (USA). VDE - Verband Deutscher Elekortechniker (Germany).

A
ABC ABC-V AGA AGA-V AGC AGC-V AGX AGX-V ATC ATM 39 39 47 47 38 38 48 48 46 46

HTC-200M HTC-210M

HTC-140M HTC-150M HTC-15M HTC-30M HTC-35M HTC-40M HTC-45M HTC-50M HTC-55M HTC-60M HTC-65M HTC-70M

51 51

M
MAX MCR MDA MDA-V MDL MDL-V MDQ MDQ-V 46 8 44 44 42 42 43 43

C
C387 C436 C515 C517 C518 C519 C520 36 45 12 16 14 12 14

P
PC-TRON 11

E
EFF ETF 9 9

S
S500 S501 S504 S504-V S505 S505-V S506 S508 SFT 20 18 22 22 24 24 26 28 7

F
FWH 40

G
GBA GBB GBB-V GDA GDA-V GDB GDB-V 49 41 41 18 18 20 20

T
TDC10 TDC11 TDC17 (C17) TDC180 (C180) 36 45 50 50

68

Application Engineers +44 (0)1509 882766 or 882760