Você está na página 1de 11

LPH SERIES - Liquid Ring Vacuum Pumps

SIHI P
umps
Pumps
www.sterlingamericas.com

SIHI PUMPS
PERFORMANCE AND RELIABILITY

Vacuum
More than 29 Hg Vacuum attainable with a single pump unit.

Higher Vacuum
Achievable by incorporating other SIHI Products.

Operational Safety
Provided by the low temperature rise of the Liquid Ring
Principle ensuring the safest compression of hazardous
and explosive vapors.

Entrained Liquid Handling


Liquid slugs and condensables pass through the pump without
damage and only a momentary reduction in performance.

Long Economical Life


Elimination of internal metallic contact minimizes maintenance
and increases life - only one moving part and no internal
lubrication required.

Low Vibration & Noise Levels


Absence of reciprocating parts assures quiet and low vibration
operation - eliminating the need for special foundations.

Low Starting Torque


Permits considerable savings in electrical starting and
control components.

Construction Flexibility
Models available in a variety of shaft seals and materials
including Cast Iron, Bronze, Stainless Steels, Hastelloys
and Titanium.

SINGLE ACTING LIQUID RING PUMPS

In a round pump body (A), a shaft mounted impeller (B) is positioned at a point eccentric to the centerline of the pump body. The centrifugal action of the rotating impeller
forces the service liquid introduced via channel (D) towards the periphery of the pump
body forming the liquid ring (C).
When pumping action is achieved, the gas mixture being handled is introduced to the
impeller through the suction port (H), in the intermediate plate (E), causing a vacuum at
the pump suction. The gas mixture fills the impeller cavity between the inside diameter of
the liquid ring and the root of the impeller blade. As the impeller rotates,
the impeller blade immersion
in the liquid ring increases
A
J
Pump
Pump Suction H
reducing the volume
Discharge
(Gas Mixture)
between the liquid
(Gas & Liquid)
ring and the root
of the impeller
blade. The result is the compression of the
Service
Liquid
gas mixture
Inlet
until it reaches
the discharge
port (J), located
in the intermediate
plate (K). The gas
mixture exits through the
D E
B C
K
discharge port.
During the compression cycle heat is
being imparted to the liquid ring. In order to maintain a temperature below the
vapor point of the service liquid, cooling
must be applied. Cooling is achieved by
continuously adding a cool supply of
service liquid to the liquid ring. The
amount of service liquid added is equal
to that discharged through the discharge
port (J) together with the compressed
gas mixture. The gas mixture and service
liquid is eventually passed through the
pump discharge for separation.

= Gas Mixture
= Service Liquid
= Gas & Liquid

The illustration is intended to depict the


operating principle of the SIHI liquid ring
pump only and should not be considered
for engineering details of construction.

SERVICE LIQUID ARRANGEMENTS

ONCE THROUGH
Used where service liquid is plentiful and
contamination is not a problem.

System Vent

Pump Suction

Benefits
Simplicity

Separator

Inlet
Check Valve

Lowest initial cost

To drain

Compound
Gauge

PI

Isolating
Valve

S
Service Liquid

Flow Regulating
Y - Strainer Isolating Valve
Valve
Solenoid Valve
(normally closed)

PARTIAL RECIRCULATION
Used where service liquid is available and
contamination problems are minimal.

System Vent

Pump Suction

Separator

Inlet
Check Valve

Benefits

Overflow

Simplicity

Compound
Gauge

Low initial cost


Reduced service liquid consumption

M
PI

Isolating
Valve
Regulating
Valve

Partial
Recirculating
Piping

Service Liquid
Flow Regulating
Valve

Y - Strainer Isolating Valve


Solenoid Valve
(normally closed)

TOTAL RECIRCULATION
Used where gases and liquids are toxic
or hazardous, and when environmental
contamination is a concern.

Benefits
Service liquid contained and
separated from nonhazardous
coolant systems
Low service liquid usage
Allows recovery of condensable
inlet gases

System Vent

Pump Suction
Separator
Inlet
Check Valve
Isolating
Valve
Compound
Gauge

Gauge
Glass

Overflow
LI

PI
Flow
Regulating
Valve

Heat Exchanger

Y- Strainer Isolating Valve


Coolant Supply
Coolant Return

Accessories for the above service liquid arrangements can be provided by


SIHI Pumps in completely piped, assembled and tested factory packages.

Medium Vacuum Performance (Dry Air)


Vacuum in inches Hg.
4
Model Number
Absolute Pressure in Inches Hg. 25.92
(Inlet x Outlet Size) Absolute Pressure in mm Hg.
658
measured in inches
Speed
Horsepower
CFM
LPH 20103 (1 x 1)
3500
*1.5
13.6

8
21.92
557
CFM
14.3

12
17.92
455
CFM
14.8

16
13.92
354
CFM
14.7

20
9.92
252
CFM
13.8

24
5.92
150
CFM
11.3

26
3.92
100
CFM
-

26.4 Average
Service
3.52
Liquid
Flow
89
CFM USGPM
1.0

LPH 20105

(1 x 1)

3500

23.5

27.0

29.0

29.5

28.0

22.0

1.0

LPH 20107

(1 x 1)

3500

29.5

32.0

33.5

34.0

31.7

23.0

1.1

LPH 3404

(1 x 1)

2
3

20
40

20
40

19
40

17
40

10
40

32

3
3

LPH 3408

(1 x 1)

1150
1750
1150
1750

3
5

40
75

40
75

38
75

34
75

23
74

65

3
3

LPH 40412

(1 x 1)

1750

7.5

118

118

118

118

117

102

60

LPH 40517

(2 x 2)

1750

10

164

167

167

167

163

147

105

LPH 50518

(2 x 2)

1150
1750

*7.5
15

152
248

153
250

155
250

151
248

142
240

118
217

82
184

70
170

8
8

LPH 50523

(2 x 2)

1150
1750

10
20

182
315

186
325

187
330

184
327

173
318

142
288

90
250

70
235

7
7

LPH 60520

(4 x 4)

1150
1450
1750

15
20
25

225
295
365

232
300
365

235
305
365

233
305
362

218
300
352

175
276
322

120
225
267

175
220

7
7
7

LPH 60527

(4 x 4)

1150
1450
1750

20
25
40

283
395
470

290
395
470

295
395
470

295
395
470

290
390
456

255
350
415

150
285
350

225
300

8
8
8

LPH 70123

(4 x 4)

880
975
1030
1150

30
*30
40
*40

455
502
540
600

455
502
540
600

455
502
540
600

455
502
540
600

440
483
520
580

375
410
440
485

285
330
340
380

259
295
300
305

10
10
10
10

LPH 70530

(5 x 5)

880
975
1030
1150

40
*40
50
60

590
685
735
825

590
685
735
820

590
685
730
812

590
675
720
795

575
655
690
760

535
590
625
685

450
485
520
545

365
410
420
430

15
15
15
15

LPH 70540

(5 x 5)

880
975
1030
1150

50
60
60
75

850
913
985
1120

850
913
985
1120

850
913
985
1120

850
913
985
1120

830
910
980
1095

770
845
910
1000

630
700
770
825

500
600
660
700

17
17
17
17

LPH 80540

(8 x 8)

700
735
880

75
75
100

1153
1235
1437

1188
1258
1470

1200
1275
1475

1190
1255
1466

1137
1220
1425

1025
1108
1320

918
980
1168

875
940
1120

27
27
27

LPH 80553

(8 x 8)

700
735
880

100
100
125

1490
1600
1890

1532
1635
1933

1560
1655
1955

1565
1650
1950

1550
1625
1905

1425
1525
1787

1210
1305
1555

1150
1250
1495

31
31
31

LPH 80557

(8 x 8)

575
680
735

75
100
125

1610
1960
2130

1610
1950
2125

1600
1935
2115

1560
1890
2080

1500
1820
2015

1350
1700
1880

1100
1410
1580

950
1140
1440

24
24
24

LPH 90554

(10 x 10)

465
600
700

100
125
150

1610
2150
2470

1610
2150
2470

1590
2150
2470

1560
2120
2440

1500
2060
2380

1354
1915
2200

1120
1670
1880

1000
1590
1765

44
44
44

LPH 90567

(10 x 10)

465
600
700

125
150
200

1830
2650
2980

1830
2650
2980

1825
2650
2980

1810
2640
2975

1760
2590
2930

1580
2420
2780

1260
2150
2460

1145
2060
2295

53
53
53

LPH 10054

(12 x 12)

410
490
565

*150
*200
*250

3000
3650
4300

3000
3720
4300

3000
3770
4300

2970
3750
4280

2900
3660
4200

2620
3445
3930

2000
3000
3500

1678
2886
3357

74
74
74

LPH 11055

(14 x 14)

335
415
475

250
*300
400

4240
5600
6300

4240
5600
6300

4240
5600
6300

4230
5550
6260

4130
5480
6150

3710
5064
5770

2600
4200
4900

2060
3828
4416

108
108
108

* Horsepower given is for motors with 1.15 service factor only. Use next larger size with 1.0 service factor motors.
This data represents average values for pumps in standard material of construction discharging against atmospheric pressure at sea level. Capacity in cubic feet per minute at inlet pressure for air at 20C
(68F) and using 15C (59F) water as the service liquid. When handling 100% saturated air see performance data on following pages.

High Vacuum Performance (Dry Air)


Model Number
(Inlet x Outlet Size)
measured in inches

Vacuum in Inches Hg.


Absolute Pressure in Inches Hg.
Absolute Pressure in mm Hg.
Speed
Horsepower
3500
2
3500
3

4
25.92
658
CFM
13.5
27.0

12
20
22.5
25
27.5
17.92 9.92 7.42 4.92 2.42
455 252 188
125 61.5
CFM CFM CFM CFM CFM
14.5 14.9 14.9 14.5 11.5
30.0 31.0 31.0 31.0 26.5

28
1.92
48.8
CFM
11.0
23.0

28.7 28.9 Average


Service
1.22 0.98
Liquid
31
25
Flow
CFM CFM USGPM
7.0
1.4
12.0
1.4

LPH 25003
LPH 25007

(1 x 1)

LPH 3704

(1 x 1)

1150
1750

3
5

25
37

25
37

25
37

25
42

25
42

21
33

18
29

20

17

4
4

LPH 3708

(1 x 1)

1150
1750

5
7.5

42
70

42
70

44
70

44
75

44
74

43
62

40
55

41

30

5
5

LPH 45312

(1 x 1)

1150
1750

5
7.5

54
88

54
90

57
102

61
110

66
112

68
102

64
95

48
70

42
61

3
3

LPH 45317

(1 x 1)

1150
1750

5
10

60
105

67
105

74
150

80
155

87
150

82
136

78
125

58
90

48
73

4
4

LPH 55312

(2 x 2)

1150
1750

7.5
*15

106
141

106
141

118
177

123
196

124
199

119
186

110
173

82
130

71
117

10
10

LPH 55316

(2 x 2)

1150
1750

10
20

112
200

112
200

135
228

145
244

148
248

130
230

118
210

87
149

76
122

11
11

LPH 55320

(2 x 2)

1150
1750

15
25

117
206

117
206

147
247

157
302

160
315

143
290

131
265

106
183

82
148

13
13

LPH 65320

(2 x 2)

1150
1450
1750

15
25
30

194
265
324

194
267
325

200
285
330

210
285
340

220
290
345

220
290
320

215
270
305

175
210
235

160
190
210

9
9
9

LPH 65327

(2 x 2)

1150
1450
1750

20
30
40

235
320
375

232
320
375

245
330
385

255
340
395

280
350
410

280
350
395

260
335
360

200
240
255

180
200
210

9
9
9

LPH 75320

(4 x 4)

880
975
1030
1150

40
40
*40
*50

370
410
425
445

385
415
430
460

420
470
485
515

445
500
515
545

460
515
535
570

430
480
495
530

405
455
470
490

315
365
370
375

295
335
335
340

19
19
19
19

LPH 75330

(4 x 4)

880
975
1030
1150

50
50
60
75

510
565
580
595

535
590
620
655

610
670
700
745

635
700
730
770

670
740
770
830

600
675
695
730

535
615
630
665

400
455
485
470

380
390
395
400

20
20
20
20

LPH 75340

(4 x 4)

880
975
1030
1150

50
60
*60
100

665
735
760
800

665
740
770
820

700
800
835
890

755
850
885
940

850
930
955
995

810
905
925
955

740
840
860
890

510
600
630
650

460
510
525
525

21
21
21
21

LPH 85340

(6 x 6)

700
735
880

100
100
125

1075 1110 1165 1180 1180


1120 1175 1220 1230 1235
1300 1325 1440 1465 1490

1105 1005 780


1180 1080 860
1450 1375 1010

695
765
840

38
38
38

LPH 85353

(6 x 6)

700
735
880

*100
125
150

1275 1290 1400 1460 1490


1325 1340 1430 1490 1540
1500 1550 1690 1760 1820

1460 1360 1080


1520 1400 1140
1770 1610 1250

980
1030
1130

50
50
50

LPH 95354

(8 x 8)

465
600
700

125
*150
*200

1340 1470 1640 1690 1710


1960 1980 2070 2100 2100
2325 2380 2460 2470 2470

1630 1550 1220


1980 1900 1440
2280 2130 1650

1030
1180
1295

71
71
71

LPH 95367

(8 x 8)

465
600
700

125
200
250

1540 1600 1770 1870 1980


2050 2130 2320 2460 2540
2420 2500 2660 2780 2860

1980 1930 1650


2450 2340 1900
2770 2640 2160

1295
1530
1650

76
76
76

LPH 10534

(8 x 8)

400
490
590

200
*250
350

2475 2500 2660 2850 2980


3130 3175 3400 3640 3750
3575 3675 4000 4220 4350

2950 2850 2350


3600 3450 2800
4180 3950 3100

1975
2260
2475

108
108
108

LPH 11535

(10 x 10)

335
415
470

*250
*350
450

3530 3540 3820 4050 4270


4520 4650 4950 5180 5360
4800 5050 5540 5750 6050

4300 4120 3400


5300 5030 3900
5850 5570 4400

2885
3240
3500

147
147
147

(1 x 1)

* Horsepower given is for motors with 1.15 service factor only. Use next larger size with 1.0 service factor motors.
This data represents average values for pumps in standard material of construction discharging against atmospheric pressure at sea level. Capacity in cubic feet per minute at inlet pressure for air at 20C
(68F) and using 15C (59F) water as the service liquid. When handling 100 % saturated air see performance data on following pages.

IF REQUIREMENTS ARE IN THE DARK BLUE AREA, A MORE EFFICIENT SELECTION CAN BE MADE FROM PUMPS LISTED ON PRECEDING PAGE.

Medium Vacuum Performance (Saturated Air)


Vacuum in inches Hg.
4
Model Number
Absolute Pressure in Inches Hg. 25.92
(Inlet x Outlet Size) Absolute Pressure in mm Hg.
658
measured in inches
Speed
Horsepower
CFM

8
21.92
557
CFM

12
17.92
455
CFM

16
13.92
354
CFM

20
9.92
252
CFM

24
5.92
150
CFM

26
3.92
100
CFM

26.4 Average
Service
3.52
Liquid
Flow
89
CFM USGPM

LPH 20103 (1 x 1)

3500

*1.5

13.8

14.6

15.2

15.2

14.4

12.2

1.0

LPH 20105 (1 x 1)

3500

23.9

27.6

29.7

30.5

29.3

23.7

1.0

LPH 20107 (1 x 1)

3500

30.0

32.7

34.3

35.1

33.1

24.8

1.1

LPH 3404

(1 x 1)

1150
1750

2
3

20
41

20
41

19
41

18
41

10
42

35

3
3

LPH 3408

(1 x 1)

1150
1750

3
5

41
76

41
77

39
77

35
77

24
77

70

3
3

LPH 40412 (1 x 1)

1750

7.5

120

120

121

122

122

110

67

LPH 40517

1750

10

167

170

171

172

170

159

118

LPH 50518 (2 x 2)

1150
1750

*7.5
15

155
252

156
255

159
256

156
256

148
251

127
234

92
207

80
194

8
8

LPH 50523 (2 x 2)

1150
1750

10
20

185
321

190
332

192
338

190
338

181
333

153
311

101
281

80
268

7
7

LPH 60520

(4 x 4)

1150
1450
1750

15
20
25

229
300
371

237
306
373

241
313
374

241
315
374

228
314
368

189
298
347

135
253
300

199
251

7
7
7

LPH 60527

(4 x 4)

1150
1450
1750

20
25
40

288
402
478

296
403
480

302
405
482

305
408
485

303
408
477

275
377
448

168
320
393

256
342

8
8
8

LPH 70123

(4 x 4)

880
975
1030
1150

30
*30
40
*40

463
511
550
611

464
512
551
612

466
515
554
615

470
518
557
619

460
505
544
606

404
442
474
523

320
370
382
427

295
336
342
348

10
10
10
10

LPH 70530

(5 x 5)

880
975
1030
1150

40
*40
50
60

600
697
748
840

602
699
750
837

605
702
748
832

609
697
743
821

601
685
721
795

577
636
674
739

505
544
584
612

416
467
479
490

15
15
15
15

LPH 70540

(5 x 5)

880
975
1030
1150

50
60
60
75

865
929
1002
1140

868
932
1005
1143

871
936
1010
1148

877
942
1017
1156

868
951
1025
1145

830
911
981
1078

707
786
864
926

570
684
752
798

17
17
17
17

LPH 80540

(8 x 8)

700
735
880

75
75
100

1173
1257
1462

1213
1284
1500

1230
1307
1512

1228
1296
1513

1189
1276
1490

1105
1195
1423

1030
1100
1311

997
1072
1277

27
27
27

LPH 80553

(8 x 8)

700
735
880

100
100
125

1516
1628
1923

1564
1669
1973

1599
1697
2004

1616
1703
2013

1621
1699
1992

1537
1645
1927

1358
1465
1745

1311
1425
1704

31
31
31

LPH 80557

(8 x 8)

575
680
735

75
100
125

1638
1994
2167

1643
1990
2169

1640
1984
2168

1610
1951
2147

1568
1903
2107

1456
1833
2027

1235
1583
1774

1083
1299
1641

24
24
24

LPH 90554

(10 x 10)

465
600
700

100
125
150

1638
2188
2513

1643
2195
2521

1630
2204
2532

1610
2188
2519

1568
2154
2489

1460
2065
2372

1257
1875
2110

1140
1812
2012

44
44
44

LPH 90567

(10 x 10)

465
600
700

125
150
200

1862
2697
3032

1868
2705
3042

1871
2717
3055

1868
2725
3071

1840
2708
3064

1704
2610
2998

1414
2413
2761

1305
2348
2616

53
53
53

LPH 10054

(12 x 12)

410
490
565

*150
*200
*250

3053
3714
4376

3062
3797
4389

3076
3865
4408

3066
3871
4418

3032
3827
4392

2825
3715
4238

2245
3368
3929

1913
3290
3827

74
74
74

LPH 11055

(14 x 14)

335
415
475

250
*300
400

4315
5699
6411

4328
5716
6430

4347
5741
6459

4367
5729
6462

4318
5730
6430

4001
5461
6222

2919
4715
5500

2348
4364
5034

108
108
108

(2 x 2)

* Horsepower given is for motors with 1.15 service factor only. Use next larger size with 1.0 service factor motors.
This data represents average values for pumps in standard material of construction discharging against atmospheric pressure at sea level. Capacity in cubic feet per minute at inlet pressure for air with 100%
saturation at 20C (68F) and using 15C (59F) water as the service liquid. When handling saturated air at higher temperatures the capacity of vacuum pumps will increase substantially; performance is
available upon application.

High Vacuum Performance (Saturated Air)


Model Number
(Inlet x Outlet Size)
measured in inches

LPH 25003

(1 x 1)

LPH 25007

(1 x 1)

LPH 3704

(1 x 1)

LPH 3708

(1 x 1)

LPH 45312

(1 x 1)

LPH 45317

(1 x 1)

LPH 55312

(2 x 2)

LPH 55316

(2 x 2)

LPH 55320

(2 x 2)

LPH 65320

(2 x 2)

LPH 65327

(2 x 2)

LPH 75320

(4 x 4)

LPH 75330

(4 x 4)

LPH 75340

(4 x 4)

LPH 85340

Vacuum in Inches Hg.


4
12
20
Absolute Pressure in Inches Hg. 25.92 17.92 9.92
Absolute Pressure in mm Hg.
658 455 252
Speed
Horsepower
CFM CFM CFM
3500
2
13.7 14.9 15.6
3500

1150
1750
1150
1750

22.5
25
27.5
7.42 4.92 2.42
188
125 61.5
CFM CFM CFM
15.8 15.9 14.0

28
1.92
48.8
CFM
14.2

28.7
1.22
31
CFM
11.1

28.9 Average
Service
0.98
Liquid
25
Flow
CFM USGPM
1.4

27.5

30.8

32.4

32.9

34.0

32.3

29.7

19.0

1.4

3
5
5
7.5

25
37
43
71

26
37
43
72

26
38
46
73

27
44
47
80

27
46
48
81

25
40
52
76

23
37
52
71

32
65

32
56

4
4
5
5

1150
1750

5
7.5

55
90

55
92

60
107

65
117

72
123

83
124

83
123

76
111

78
114

3
3

1150
1750

5
10

61
107

69
108

77
157

85
165

95
164

100
166

101
162

92
142

89
136

4
4

1150
1750

7.5
*15

108
143

109
145

123
185

131
208

136
218

145
227

142
224

130
205

132
218

10
10

1150
1750

10
20

114
204

115
205

141
238

154
259

162
272

158
280

153
271

137
235

141
227

11
11

1150
1750

15
25

119
210

120
211

154
258

167
321

175
345

174
353

169
343

167
289

153
275

13
13

1150
1450
1750

15
25
30

197
270
330

199
274
333

209
298
345

223
303
361

241
318
378

268
353
390

278
349
394

276
332
371

298
354
391

9
9
9

1150
1450
1750

20
30
40

239
326
382

238
328
384

256
345
403

271
361
419

307
383
449

341
426
481

336
433
465

316
379
403

335
372
391

9
9
9

880
975
1030
1150

40
40
*40
*50

377
417
432
453

395
425
441
472

439
491
507
538

472
531
547
579

504
564
586
624

524
585
603
646

524
588
608
633

498
577
585
592

549
624
624
633

19
19
19
19

880
975
1030
1150

50
50
60
75

519
575
590
605

548
605
636
672

638
701
732
779

674
743
775
818

734
811
844
909

731
822
847
889

692
795
814
860

632
719
766
743

707
726
735
745

20
20
20
20

880
975
1030
1150

50
60
*60
100

677
748
773
814

682
759
789
841

732
836
873
931

802 931 987 957


806
902 1019 1102 1086 948
940 1046 1127 1112 995
998 1090 1163 1151 1027

856
949
977
977

21
21
21
21

(6 x 6)

700
735
880

100
100
125

1094 1138 1218 1253 1293 1346 1299 1232


1140 1205 1276 1306 1353 1437 1396 1359
1323 1358 1506 1555 1632 1766 1778 1596

1294
1424
1564

38
38
38

LPH 85353

(6 x 6)

700
735
880

*100
125
150

1297 1323 1464 1550 1632 1778 1758 1706


1348 1374 1495 1582 1687 1851 1810 1801
1526 1589 1767 1869 1994 2156 2081 1975

1824
1917
2103

50
50
50

LPH 95354

(8 x 8)

465
600
700

125
*150
*200

1364 1507 1715 1794 1873 1985 2004 1927


1994 2030 2164 2230 2301 2412 2456 2275
2366 2440 2572 2622 2706 2777 2754 2607

1917
2196
2411

71
71
71

LPH 95367

(8 x 8)

465
600
700

125
200
250

1567 1640 1851 1985 2169 2412 2495 2607


2086 2184 2426 2612 2783 2984 3025 3002
2463 2563 2781 2952 3133 3374 3413 3413

2411
2848
3071

76
76
76

LPH 10534

(8 x 8)

400
490
590

200
*250
350

2519 2563 2781 3026 3265 3593 3684 3713


3185 3255 3555 3865 4108 4385 4460 4424
3638 3768 4182 4480 4765 5091 5107 4898

3676
4207
4607

108
108
108

LPH 11535

(10 x 10)

335
415
470

*250
*350
450

3592 3629 3994 4300 4678 5237 5326 5372


4600 4767 5176 5500 5872 6455 6503 6162
4884 5177 5793 6105 6628 7125 7201 6952

5370
6031
6515

147
147
147

* Horsepower given is for motors with 1.15 service factor only. Use next larger size with 1.0 service factor motors.
This data represents average values for pumps in standard material of construction discharging against atmospheric pressure at sea level. Capacity in cubic feet per minute at inlet pressure for air with
100% saturation at 20C (68F) and using 15C (59F) water as the service liquid. When handling saturated air at higher temperatures the capacity of vacuum pumps will increase substantially;
performance is available upon application.

IF REQUIREMENTS ARE IN THE DARK BLUE AREA, A MORE EFFICIENT SELECTION CAN BE MADE FROM PUMPS LISTED ON PRECEDING PAGE.

ENGINEERED PACKAGES

SINGLE SOURCE RESPONSIBILITY:


Purchase Order

Contact

Warranty

SIHI Pumps has competent engineering teams backed by more than sixty years
experience to design and build packages custom suited to your requirements.

TYPICAL APPLICATIONS
Drying
Distillation
Evaporation Crystallization
Vapor Recovery
Deaeration
Sterilization
Filtration
Evisceration
Impregnation
Extrusion
Condensor Exhaust
Vacuum Conveyance
Priming
Vacuum Packaging
Central Vacuum Systems

LPH Rev 1.5 11/04

Você também pode gostar