Você está na página 1de 190

ProCash 2000xe ProCash 2000xe USB

Installation Guide

Self-Service Systems

Questions and suggestions

Do you have ...

... any questions or suggestions regarding this manual?

Please contact the following address giving the order number of this manual in your message: Address: WINCOR NIXDORF International GmbH Handbuchredaktion BD PSD 43 D - 33094 Paderborn Germany Fax: +49 (0) 52 51 693-62 09 E-mail: manuals.hardware@wincor-nixdorf.com

... any technical questions or problems? Please contact your local representative.

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

ProCash 2000xe ProCash 2000xe USB

Installation Guide

Edition January 2009

Copyright Information and trademarks WINCOR NIXDORF International GmbH 2009


All rights, including rights of translation and rights of reproduction by reprinting, copying or similar methods, even of parts, are reserved. Any violations give rise to a claim for damages. All rights, including rights created by patent grants or registration of a utility model or design, are reserved. Delivery subject to availability; right of technical modifications reserved. All names of hardware and software products mentioned in this manual are trade names and/or trademarks of their respective manufacturers.

This manual was produced using paper treated with chlorine-free bleach.

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Contents
Introduction............................................................................................... Symbols used in this guide......................................................................... Important safety precautions ...................................................................... Installation notes.................................................................................... General safety precautions ................................................................... 1 2 3 3 3

Planning the Installation .......................................................................... 7 Device dimensions ..................................................................................... 7 ProCash 2000xe / 2000xe USB with 4-cassette dispenser .................. 8 Frontload device with standard lock................................................. 8 Frontload device with customer-specific lock................................... 9 Frontload device with standard lock and barcode reader .............. 10 Frontload device with customer-specific lock and barcode reader ............................................................................................. 11 Rearload device without barcode reader ....................................... 12 Rearload device with barcode reader ............................................ 13 ProCash 2000xe / 2000xe USB with 5-cassette dispenser ................ 14 Rearload device without barcode reader ....................................... 14 Rearload device with barcode reader ............................................ 15 Installation options for the device versions............................................... 16 Installation without frame (free-standing) ............................................ 17 Installation with frame for complete integration................................... 18 View with frame for complete integration ....................................... 18 Wall opening for installation with frame for complete integration....................................................................................... 19 Installation with window frame............................................................. 20 View with window frame ................................................................. 20 Wall opening for installation with window frame ............................ 22 Installation with frame for partial integration with light ........................ 24 View of device with frame partial integration and light box ............ 24 Wall opening for installing the device with a frame for partial integration with light box................................................................. 25 Installation with frame for partial integration without light box............. 26 View of device with frame for partial integration without light box.................................................................................................. 26

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Contents Wall opening for installing the device with a frame for partial integration without light box ............................................................ Vents ......................................................................................................... Storage if construction work is not yet complete ...................................... Space required for operation and maintenance ....................................... Device with standard lock .................................................................... Device with customer-specific lock...................................................... Installation site requirements .................................................................... Load-carrying capacity......................................................................... Protection from removal by force in compliance with EN and VdS guidelines............................................................................................. Installation frame....................................................................................... General ................................................................................................ Securing the installation frame ............................................................ Dimensions of safe attachment points................................................. Dimensions of cable areas .................................................................. Tear-off sensor.......................................................................................... Drilling diagrams ....................................................................................... Drilling diagram (frontload) .................................................................. Drilling diagram (rearload) ................................................................... Power and data cables ............................................................................. General information ............................................................................. Power supply ....................................................................................... Remote status indicator ....................................................................... Camera connection.............................................................................. Dimensions of the frame logo ................................................................... Transport path requirements .................................................................... Installation ............................................................................................... Removing the packaging .......................................................................... Removing the shipping crate .................................................................... General ................................................................................................ Removing the shipping crate ............................................................... Mounting sets............................................................................................ Mounting set for standard frame 01750006706 .................................. Mounting set 01750051579 for CEN frame......................................... Mounting set 01750078516 (for UL/CEN L safe) on installation frame.................................................................................................... Mounting set 01750051578 (for CEN III/CEN IV safe) on installation frame..................................................................................

27 28 28 29 29 32 35 35 36 37 37 37 38 39 40 41 42 43 44 44 46 46 47 47 48 53 53 54 54 55 56 56 57 57 57

II

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Contents Overview of installation types ................................................................... 58 Installation without frame.......................................................................... 59 Installing the installation frame ............................................................ 59 Mounting the device on the installation frame..................................... 64 Lifting the cash media dispenser (CMD-V4) up ............................. 64 Screwing the device on the installation frame................................ 65 Pushing the cash media dispenser (CMD-V4) down ..................... 66 Installing the power and data cables in the device ........................ 67 Further procedure for CEN installation .......................................... 68 General........................................................................................... 68 Installation with frame for complete integration ........................................ 69 Mounting the installation frame ........................................................... 69 Mounting the device on the installation frame..................................... 74 Lifting the cash media dispenser (CMD-V4) up ............................. 75 Screwing the device on the installation frame................................ 76 Pushing the cash media dispenser (CMD-V4) down ..................... 76 Installing the power and data cables in the device ........................ 77 Further procedure for CEN installation .......................................... 78 General........................................................................................... 78 Installing frame for complete integration in wall .................................. 79 View of the frame (completely assembled) .................................... 79 Pre-assembling the frame .............................................................. 80 Mounting the frame ........................................................................ 82 Connecting the light........................................................................ 85 Adjusting the cover......................................................................... 86 Installation with window frame.................................................................. 88 Mounting the installation frame ........................................................... 88 Mounting the device on the installation frame..................................... 94 Lifting the cash media dispenser (CMD-V4) up ............................. 95 Screwing the device on the installation frame................................ 96 Pushing the cash media dispenser (CMD-V4) down ..................... 96 Installing the power and data cables in the device ........................ 97 Further procedure for CEN installation .......................................... 98 General........................................................................................... 98 Installing the window frame ................................................................. 99 View of the frame for up to 50 mm (1.97") thick walls (completely assembled) ................................................................. 99 View of the frame for up to 160 mm (6.3") thick walls (completely assembled) ............................................................... 100 Pre-assembling the frame for up to 50 mm (1.97") and

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

III

Contents 160 mm (6.30") thick walls ........................................................... Mounting the frame....................................................................... Connecting the light on frames for up to 50 mm (1.97") and 160 mm (6.30") thick walls ........................................................... Adjusting the cover for frames for up to 50 mm (1.97") and 160 mm (6.30") thick walls ........................................................... Installation with frame for partial integration with light box ..................... Installing the installation frame .......................................................... Mounting the device on the installation frame ................................... Lifting the cash media dispenser (CMD-V4) up ........................... Screwing the device on the installation frame .............................. Pushing the cash media dispenser (CMD-V4) down ................... Installing the power and data cables in the device....................... Further procedure for CEN installation......................................... General ......................................................................................... Installing the frame for partial integration with light box .................... View of the frame (completely assembled) .................................. Pre-assembling the frame ............................................................ Mounting the frame....................................................................... Connecting the light...................................................................... Adjusting the cover ....................................................................... Installation with frame for partial integration without light box ................ Mounting the installation frame.......................................................... Mounting the device on the installation frame ................................... Lifting the cash media dispenser (CMD-V4) up ........................... Screwing the device on the installation frame .............................. Pushing the cash media dispenser (CMD-V4) down ................... Installing the power and data cables in the device....................... Further procedure for CEN installation......................................... General ......................................................................................... Installing the frame for partial integration without light ...................... View of the frame (completely assembled) .................................. Pre-assembling the frame ............................................................ Mounting the frame....................................................................... Start-up ................................................................................................... Installing the Remote Status Indicator ............................................... Remote status indicator - standard......................................................... Delivery package ............................................................................... Installation.......................................................................................... 101 102 105 106 108 108 113 114 115 115 116 117 117 118 118 119 121 124 125 128 128 133 134 135 135 136 137 137 138 138 139 142 144 145 145 145 146

IV

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Contents Connection to the relay panel for external features .......................... Remote status indicator - audio.............................................................. Delivery package ............................................................................... Installation ......................................................................................... Connection to the relay panel for external features .......................... Shortening the cables............................................................................. Adapting the cable length at the relay panel end .............................. Adapting the cable length at the standard remote status indicator end..................................................................................................... Adapting the cable length at the remote status indicator (audio)...... Appendix ............................................................................................... Check list for installation preparations for self-service systems............. General information ........................................................................... Preparations ...................................................................................... Construction work......................................................................... Power and data cables................................................................. Organizational preparations ......................................................... Delivery and installation ............................................................... Flooring materials on the path of transport .................................. Notes concerning installation preparation ......................................... Technical data ........................................................................................ General installation conditions .......................................................... Electrical characteristics of the supply network ........................... Device conditions ......................................................................... Installation specifications ............................................................. Environmental conditions ............................................................. Compliance with standards and certifications ................................... Standards met .............................................................................. Conformity .................................................................................... Notes concerning radio interference suppression and electrical safety............................................................................. FCC Rules and Canadian Standard ICES - 003.......................... UL 291 .......................................................................................... Certification for data transmission................................................ Environmental protection........................................................................ Environmentally and recycling-friendly product development........... Saving energy.................................................................................... Disposing of used consumables ....................................................... Labels on plastic case parts .............................................................. 147 149 149 150 152 154 154 154 157 161 161 162 162 162 163 163 164 164 165 167 167 167 168 169 171 173 173 173 173 174 174 174 175 175 175 175 175

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Contents Returning, recycling and disposing of used units and consumables...................................................................................... 176

VI

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Abbreviations
B BNC C CE Communaut Europenne (European Community) Declaration of Conformity Certification of Electrical Equipment Comit Europen de Normalisation (European Committee for Standardization) Code of Federal Regulation Card Identification Module (security module) Bayonet Nut Connector EMA EMC EN EPP F FCC G GmbH Limited liability company I ICES IEC Interference Causing Equipment Standards International Electrotechnical Commission International Protection International Organization for Standardization Federal Communications Commission EEC European Economic Community Intruder alarm system Electromagnetic Compatibility European standard Encrypted PIN Pad

CEE CEN

CFR CIM

CMD-V4 Cash Media Dispenser Version 4 CSA D DT E EC EDM European Community Encryption / Decryption Module Data Transmission Canadian Standards Association

IP ISO

L L N PE Line Neutral Protective Earth

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

VII

Abbreviations M MM Modular Marker of ID card (evaluation by means of security modules like MM box or CIM 86)

R RSI S SELV Safety Extra-Low Voltage T TN network Power supply network in accordance with EN 60950 U UL UPS USB V VdS Association of Property Insurance Companies Underwriters Laboratories Inc. Uninterruptible Power Supply Universal Serial Bus Remote Status Indicator

VIII

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Introduction
This installation guide gives you all the information you need to plan the installation of and to install the ProCash 2000xe or the ProCash 2000xe USB (hereinafter called ProCash 2000xe / ProCash 2000xe USB). The ProCash 2000xe / 2000xe USB is available in the following versions: ProCash 2000xe / 2000xe USB with 4-cassette cash media dispenser in frontload and rearload devices ProCash 2000xe / 2000xe USB with 5-cassette cash media dispenser in rearload devices The following accessories are available: 35 mm (1.38") frames for: Complete integration in the wall Window frame installation Partial integration with and without light box Remote status indicator (RSI): RSI - standard RSI - audio

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Symbols used in this guide

Introduction

Symbols used in this guide


Text following this mark represents an item in a list. " " Text in quotation marks contains references to other chapters or sections in this document.

Paragraphs following this symbol are actions to be performed in the order in which they are specified. Text following this symbol have to be given special attention in order to avoid damage or injury.

This symbol identifies paragraphs which contain general notes to facilitate use of the device and help avoid operating errors.

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Introduction

Important safety precautions

Important safety precautions


Please read the following notes carefully before doing any work on the device.

Installation notes
When installing the device and/or doing any work on it, make sure that it is disconnected from power.

General safety precautions


This device complies with the relevant safety regulations for information processing equipment. When moving the device from a cold to a warm environment, do not operate it for at least two hours to prevent possible damage caused by condensation. Only use the original packaging material to transport the device. Note the warning and information labels on the device. The device is equipped with a safety-tested power cable. It must be connected only to a suitable grounded outlet. Only replace the lighting unit of the frame logo when the device is turned off. Always hold the plug when removing the power cable. Never pull the cable itself. Install cables in such a way that they will not be stepped on or tripped over or damaged or crushed in any way. Have damaged power cables replaced immediately. Make sure that there is always free access to the sockets used or to the electrical circuit-breakers of the house installation. In case of an emergency (e.g. damaged cabinets, controls or power cables, liquids or foreign objects in the device) take the following steps:

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Important safety precautions Deactivate the device immediately by:

Introduction

Switching off the automatic circuit-breaker or removing the fuse inset from the fuse holder in the distribution box of the building installation; Disconnecting the plug connectors of the power supply cables from the grounded sockets in the building installation; Switching off the ON/OFF switch on the power distributor; Inform the customer service responsible for you. During a thunderstorm, data transmission lines must not be connected or disconnected. Always keep the device's vents free from obstruction to ensure proper air circulation and to prevent malfunctions resulting from overheating. Only use accessories and extension components that have been approved by us. Nonobservance can result in damage to the device or violations of regulations concerning safety, radio interference and ergonomical requirements. Note that there are only safety extra-low voltage circuits (SELV circuits) if you want to feed voltage from an external source into prepared cables to install additional electronics (e.g. connection for an intruder alarm system). To clean the device only use cleaning agents approved by WINCOR NIXDORF International GmbH(see chapter "Appendix", section "Approved cleaning materials" in the operating manual).

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Introduction Repairs

Important safety precautions

Repair work may only be carried out by authorized personnel. Unauthorized opening of the device or repair work carried out improperly could result in considerable danger to the user. In case of noncompliance, WINCOR NIXDORF International GmbH excludes all liability.

Lithium batteries There is danger of fire or explosion if the batteries are handled improperly. It is therefore important to note the following points: Avoid short circuits. Never recharge the battery. Avoid temperatures above + 100 C (+ 212 F). Do not try to open the battery by force. Do not allow the battery to come into contact with water or fire. Only replace it by the same or an equivalent type recommended by WINCOR NIXDORF International GmbH (see chapter "Appendix", section "Consumables" in the operating manual). Dispose of used batteries in compliance with national regulations and the manufacturer's specifications.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Important safety precautions

Introduction

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation


This chapter provides you with all the information you need to prepare the installation.

Device dimensions
i
All dimensions are specified in millimeters (inches). The views of the device are not drawn to scale. All device edges have a radius of 3 mm (0.12").

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Device dimensions

Planning the Installation

ProCash 2000xe / 2000xe USB with 4-cassette dispenser


Frontload device with standard lock
639 (25.16")

1472 (57.95")

1445 (56.89")

25 (0.98")

594 (23.39") 600 (23.62")

3 (0.12") 845 (33.27") 848 (33.39") 1050 (41.34")

Installation frame

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

870 (34.25")

Planning the Installation

Device dimensions

Frontload device with customer-specific lock


639 (25.16")

1472 (57.95")

1445 (56.89")

25 (0.98")

594 (23.39") 600 (23.62")

3 (0.12") 845 (33.27") 848 (33.39") 925 (36.42") 1075 (42.32")

Installation frame

870 (34.25")
9

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Device dimensions

Planning the Installation

Frontload device with standard lock and barcode reader


639 (25.16")

1472 (57.95")

1445 (56.89")

25 (0.98")

594 (23.39") 600 (23.62")

3 (0.12") 845 (33.27") 848 (33.39") 900 (35.43") 1043 (41.06")

Installation frame

10

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

778 (30.63") 870 (34.25")

Planning the Installation

Device dimensions

Frontload device with customer-specific lock and barcode reader


639 (25.16")

1472 (57.95")

1445 (56.89")

25 (0.98")

594 (23.39") 600 (23.62")

3 (0.12") 845 (33.27") 848 (33.39") 1068 (42.05")

Installation frame

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

785 (30.91") 870 (34.25")


11

Device dimensions

Planning the Installation

Rearload device without barcode reader


639 (25.16") 235 (9.25")

1835 (72.24")

1472 (57.95")

1445 (56.89")

72/43* (2.84"/1.69"*)

25 (0.98")

594 (23.39") 600 (23.62")

3 (0.12) 845 (33.27) 848 (33.39") 1050 (41.34")

1 *

Installation frame Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83")

12

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

870 (34.25")

Planning the Installation

Device dimensions

Rearload device with barcode reader


639 (25.16") 235 (9.25")

1835 (72.24")

1472 (57.95")

1445 (56.89")

72/43* (2.84"/1.69"*)

25 (0.98")

594 (23.39") 600 (23.62")

3 (0.12) 845 (33.27) 848 (33.39") 1043 (41.06")

1 *

Installation frame Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83")

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

778 (30.63") 870 (34.25")


13

Device dimensions

Planning the Installation

ProCash 2000xe / 2000xe USB with 5-cassette dispenser


Rearload device without barcode reader
639 (25.16") 235 (9.25")

1975 (77.76") 1585 (62.4")

1612 (63.47")

72/43* (2.84"/1.69"*)

25 (0.98")

594 (23.39") 600 (23.62")

3 (0.12") 845 (33.27") 848 (33.39") 1050 (41.34")

1 *

Installation frame Standard lock: 43 mm (1.69"), customer-specific lock: max. 72 mm (2.83")

14

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

1010 (39.76")

Planning the Installation

Device dimensions

Rearload device with barcode reader


639 (25.16") 235 (9.25")

1975 (77.76")

1612 (63.47")

1585 (62.4")

72/43* (2.84"/1.69"*)

25 (0.98")

594 (23.39") 600 (23.62")

3 (0.12") 845 (33.27") 848 (33.39") 900 (35.43") 1043 (41.06")

1 *

Installation frame Standard lock: 43 mm (1.69") Customer-specific lock: max. 72 mm (2.83")

918 (36.14") 1010 (39.76")


15

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Installation options for the device versions

Planning the Installation

Installation options for the device versions


i
For safety reasons we recommend installing a rearload unit through the wall (see possible installation with frame). When installing a rearload system as a free-standing ATM or when installing a frontload unit always contact your insurance company beforehand. In case of doubt contact your Wincor Nixdorf consultant. The following table shows an overview of the installation options for the different device versions. Installation options Frontload with 4-cassette dispenser yes no no Rearload with 4-cassette dispenser yes yes yes Rearload with 5-cassette dispenser yes no yes

Installation without frame (free-standing) Installation with frame for complete integration Installation with window frame Installation with frame for partial integration with light box Installation with frame for partial integration without light box

yes

yes

no

yes

yes

no

Observe the necessary operation and maintenance space for the various types of installation (see section "Space required for operation and maintenance"). The area specified for the installation of the frame requires a short tool (see section "Space required for operation and maintenance").

16

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Installation options for the device versions

Installation without frame (free-standing)

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

17

Installation options for the device versions

Planning the Installation

Installation with frame for complete integration


i
Both the rearload device with the standard lock as well as the rearload device with a customer-specific lock can be installed with a frame for complete integration.

View with frame for complete integration

If the ProCash 2000xe / 2000xe USB is installed with a frame for integration in the wall, the unit will not be flush with the wall. This must be taken into account when laying the flooring (see chapter "Installation", section "Installation with frame for complete integration").

To open the light box, there must be at least a clearance of 150 mm (5.91") at the front between light box and ceiling.

18

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Installation options for the device versions

Wall opening for installation with frame for complete integration


If a ProCash 2000xe / 2000xe USB is to be installed with a frame for complete integration in the wall, a wall opening must be provided as shown in the figure below.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

19

Installation options for the device versions

Planning the Installation

Installation with window frame


i
Both the rearload device with the standard lock as well as the rearload device with a customer-specific lock can be installed with a window frame.

View with window frame


Frame for a wall thickness of up to 50 mm max. (1.97")

1 *

Inside wall (device side) 2 devices with 5-cassette dispenser

Outside wall

To open the light box, there must be at least a clearance of 150 mm (5.91") at the front between light box and ceiling.

20

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Installation options for the device versions

Frame for a wall thickness of up to 160 mm max. (6.30")

1 *

Inside wall (device side) 2 devices with 5-cassette dispenser

Outside wall

To open the light box, there must be at least a clearance of 150 mm (5.91") at the front between light box and ceiling.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

21

Installation options for the device versions

Planning the Installation

Wall opening for installation with window frame


If a ProCash 2000xe / 2000xe USB is to be installed with a window frame in the wall, a wall opening must be provided as shown in the figure below. Wall thickness 50 mm (1.97")

1 *

Inside wall (device side) 2 device with 5-cassette dispenser

Outside wall

22

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation Wall thickness 160 mm (6.30")

Installation options for the device versions

1 *

Inside wall (device side) 2 device with 5-cassette dispenser

Outside wall

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

23

Installation options for the device versions

Planning the Installation

Installation with frame for partial integration with light


View of device with frame partial integration and light box

Both the device with the standard lock as well as the device with a customer-specific lock (deeper front door) can be installed with a frame and partly integrated in the wall. The dimensions of the frame for partial integration of the device in a wall are shown here for the rearload version with standard lock as an example. The frame for the frontload version with standard lock has the same dimensions.

To open the light box, there must be at least a clearance of 150 mm (5.91") at the front between light box and ceiling.

24

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Installation options for the device versions

Wall opening for installing the device with a frame for partial integration with light box
If a ProCash 2000xe / 2000xe USB is to be installed with a frame for partial integration with light box in the wall, a wall opening must be provided as shown in the figure below.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

25

Installation options for the device versions

Planning the Installation

Installation with frame for partial integration without light box


View of device with frame for partial integration without light box

Both the device with the standard lock as well as the device with a customer-specific lock (deeper front door) can be installed with a frame and partly integrated in the wall. The dimensions of the frame for partial integration of the device in a wall are shown here for the rearload version with standard lock as an example. The frame for the frontload version with standard lock has the same dimensions.

26

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Installation options for the device versions

Wall opening for installing the device with a frame for partial integration without light box
If a ProCash 2000xe / 2000xe USB is to be installed with a frame for partial integration without light box in the wall, a wall opening must be provided as shown in the figure below.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

27

Vents

Planning the Installation

Vents
The device features forced air ventilation on the rear side by means of a builtin fan. Additionally, there are vents on either side of the top part. Make sure that the distance between these vents and the wall is always at least 50 mm (1.97").

Vents

Storage if construction work is not yet complete


i
If the system is installed while interior construction is still underway, be sure to protect it against dirt and dust from the construction. You may use the plastic packing of the system for this purpose.

28

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Space required for operation and maintenance

Space required for operation and maintenance


Device with standard lock
The following figure shows the space which is required for operation and maintenance. Ventilation space Operation and maintenance space Additional operation and maintenance space, right or left Additional space required for the installation (for reaching the fastening screws in the safe). Area for frame installation

The area specified for the installation of the frame requires a short tool.

(Illustration on the following pages)

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

29

Space required for operation and maintenance Frontload

Planning the Installation

840 (33.07")

750 (29.53")

210 (8.27")

50 (1.97") 120 (4.72") 50 (1.97") 400 (15.75") 120 (4.72") 50 (1.97") 300 (11.81") 1800 (70.87") 180 (7.09") 600 (23.62") 1300 (51.18") 300 (11.81") 835 (32.87")
01750058375 G

30

900 (35.43")

ProCash 2000xe / 2000xe USB - Installation Guide

Planning the Installation Rearload

Space required for operation and maintenance

1280 (50.39") 600 (23.62") 400 (15.75")

555 (21.85")

530 (20.87")

120 (4.72") 50 (1.97") 100 (3.94")

120 (4.72") 50 (1.97") 100 (3.94")

848 (33.39")

280 (11.02")

400 (15.75")

880 (34.65") 300 (11.81") 800 (31.5") 300 (11.81")

1680 (66.14")

1030 (40.55")

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

31

Space required for operation and maintenance

Planning the Installation

Device with customer-specific lock


The following figure shows the space which is required for operation and maintenance. Ventilation space Operation and maintenance space Additional operation and maintenance space, right or left Additional space required for the installation (for reaching the fastening screws in the safe). Area for frame installation

The area specified for the installation of the frame requires a short tool.

(Illustration on the following pages)

32

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation Frontload

Space required for operation and maintenance

840 (33.07")

750 (29.53")

210 (8.27")

50 (1.97") 120 (4.72") 50 (1.97") 400 (15.75") 120 (4.72") 50 (1.97") 330 (12.99") 1800 (70.87") 600 (23.62") 1330 (52.36") 330 (12.99") 180 (7.09") 835 (32.87")

900 (35.43")

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

33

Space required for operation and maintenance Rearload

Planning the Installation

1305 (51.38") 600 (23.62") 400 (15.75")

555 (21.85")

530 (20.87")

120 (4.72") 50 (1.97") 100 (3.94")

120 (4.72") 50 (1.97") 100 (3.94")

848 (33.39")

305 (12.01")

400 (15.75")

880 (34.65") 300 (11.81") 800 (31.5") 300 (11.81")

34

ProCash 2000xe / 2000xe USB - Installation Guide

1680 (66.14")
01750058375 G

1030 (40.55")

Planning the Installation

Installation site requirements

Installation site requirements


The installation area must be flat and on one level with the surrounding floor. Any differences in floor height in the installation area must be leveled out with rustproof shims, for example. This is not part of the installation procedure, but must be done by a contractor. When choosing the installation site, make sure that bright room lighting, light reflections and direct sunlight shining on the screen are avoided, the requirements concerning ambient conditions can also be met in lobbies (see chapter "Appendix", section "Technical data"), existing underfloor heating, energy and/or communication cables, etc., are not damaged when drilling the mounting holes. If necessary, appropriate arrangements must be made.

When selecting the installation site, noise emission should be taken into account. Fans in operation or the noise produced during a transaction could disturb people in the immediate vicinity of the device and may therefore need to be diminished with soundproofing (e.g. soundproof cabinets, etc.). They must comply with the environmental conditions that apply to the specific device (see chapter "Appendix", section "Technical data") and the maintenance areas (see section "Space required for operation and maintenance").

Load-carrying capacity
Ensure that the installation site has the required load-carrying capacity. You will find the relevant device weight in the section "Installation specifications" in the chapter "Appendix".

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

35

Installation site requirements

Planning the Installation

Protection from removal by force in compliance with EN and VdS guidelines


i
In accordance with the applicable guidelines VdS 2527, VdS 2527-S1, EN 1143-1 and EN 1143 - 1 prAl safe and installation frame form a unit. For this reason CEN safes may only be mounted with the certified and approved installation frames. If the guidelines are not observed, the CEN certification becomes invalid.

The device must be screwed to the load-bearing substructure of the installation site or mounted on a suitable base. Using the prescribed mounting materials, the following values relating to resistance to removal of the safe from the installation frame are reached: Resistance grade III IV Minimum force required 50 kN 100 kN

The operator must provide a suitable base to protect it from removal by force. We recommend reinforced concrete B25 (EN206 C20/25) or a higher-quality concrete.

Installation on raised or cavity flooring as well as on a floating floor is not permissible according to the CEN standard. In case of a mounting structure other than the one specified in the respective sections "Mounting the installation frame" in the chapter "Installation", always contact your insurance company beforehand.

36

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Installation frame

Installation frame
General
A ProCash 2000xe / 2000xe USB cannot be installed without the installation frame. The installation frame is secured to the floor at the respective attachment points (see sections "Drilling diagram (frontload)" and "Drilling diagram (rearload)"). Then the device (safe) is screwed to the installation frame. How the safe is secured on the installation frame depends on the safe construction type (UL, CEN L or CEN III, CEN IV). For CEN safes, the safe construction types are distinguished in resistance grades. The label showing the resistance level is located on the inside of the safe door. Openings which are not used have to be closed by putting in the filling pieces.

For mounting material see section "Mounting sets" in the chapter "Installation".

Securing the installation frame


The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type (UL, CEN L, CEN III, CEN IV). These attachment points are at position (2) and the alternative attachment points are at position (3) (see following illustration). The supplied installation frame can be used for the frontload and rearload versions.

If the mounting set is not provided, use equivalent fastening material.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

37

Installation frame

Planning the Installation

Dimensions of safe attachment points


i
The installation frame must be secured using one threaded rod per group of holes A to D. The installation frame is secured with four threaded rods.

62 (2.44")

594 (23.39") 437 (17.21") 157 (6.18") 1 2 A 3 B

842 (33.15") 780 (30.71")

4 5

3 C 2 1 6
1 2 3 4 5 6 Attachment points of safe Attachment points of installation frame Alternative attachment points of installation frame Attachment point of tear-off sensor rearload Attachment point of tear-off sensor frontload This side must always point towards the customer panel

38

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Installation frame

Dimensions of cable areas


In the following illustration the cable feed openings are dimensioned based on the outer edge of the installation frame. The dimensions are the same for the Frontload and the Rearload version.

197 (7.76") 117 (4.61") 25 (0.98")

1 3 3 3

3 2

3 1

4
1 2 3 4 Cable lead-ins in the installation frame Cable feed openings underneath the installation frame Area for cables This side must always point towards the customer panel

232 25 (0.98") (9.13") 262 (10.32") 391 (15.39") 451 (17.76") 580 (22.84") 610 (24.03") 842 (33.15") 2 2
39

594 (23.39") 569 (22.4") 532 (20.95") 482 (18.98") 477 (18.78") 397 (15.63")

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Tear-off sensor

Planning the Installation

Tear-off sensor
i
All safes and installation frames have holes for mounting a tear-off sensor.

To ensure that the tear-off sensor can be mounted after the device has been installed, a hole for the tear-off sensor has to be drilled at the time the installation frame is mounted. To be able to mount the tear-off sensor, the hole has to be cleaned with a vacuum cleaner and a resin cartridge (e.g. UPAT multicone, Fischer resin cartridge R M) has to be inserted. Thus the alarm technician will be able to mount the tear-off sensor in the safe easily after the device is installed (see also illustration "Mounting structure" in the respective sections of the chapter "Installation"). Ask your alarm technician about the size of the hole and the cartridge. The maximum diameter for the hole to take the fixing is 16 mm (0.63") in the installation frames 22 mm (0.87") in safe The mounting material (threaded rod, cartridge) is to be provided by the alarm technician. The length of the threaded rod depends on the installation frame you use (see chapter "Installation").

No power or data cables may be installed below the CMD-V4.

40

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Drilling diagrams

Drilling diagrams
The following figures specify the distance from the edge of the different device versions of the drill holes that are used to secure the ProCash 2000xe / 2000xe USB with installation frame. The position of the installation frame and thus of the bore diagram also depends on the frame version that is used. You will find more information on this in the chapter "Installation".

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

41

Drilling diagrams

Planning the Installation

Drilling diagram (frontload)


i
The installation frame is 3 mm (0.12") smaller than the safe all around.

500 (19.69") 440 (17.32") 160 (6.3") 114 (4.49")

Drilling depth: Holes for installation frame: Hole for tear-off sensor:

733 (28.86") 663 (26.1") 184 (7.24")

at least 180 mm (7.09") with 125 mm (4.92") in concrete. For the hole diameter please refer to the mounting instructions of the caulking cartridge. at least 40 mm (1.57") in concrete; Consult your alarm technician about the size of the hole and the cartridge.

42

ProCash 2000xe / 2000xe USB - Installation Guide

598 (23.54")
01750058375 G

Planning the Installation

Drilling diagrams

Drilling diagram (rearload)


i
The installation frame is 3 mm (0.12") smaller than the safe all around.

500 (19.69") 440 (17.32") 160 (6.3") 114 (4.49") 250 (9.84")

Drilling depth: Holes for installation frame: Hole for tear-off sensor:

733 (28.86") 663 (26.1") 184 (7.24")

at least 180 mm (7.09") with 125 mm (4.92") in concrete. For the hole diameter please refer to the mounting instructions of the caulking cartridge. at least 40 mm (1.57") in concrete; Consult your alarm technician about the size of the hole and the cartridge.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

43

Power and data cables

Planning the Installation

Power and data cables


General information
When the cables enter the device from below, make sure that the cables cannot be sheared off when the system is moved. To connect the device, power and data cables are required. In standard deliveries, the connections for all the device's power and data cables are situated near the cable feed opening in the safe. The power cable that is included in delivery has a standard length of 2.5 m (8.20 ft). The device is shipped with one power cable. Other ready-to-use lengths of power and data cables can be ordered if needed via the hardware configurator or must be provided by the customer. Please refer to the corresponding illustrations in this guide for the positioning of the cables. To lay the cables inside the installation frame and in the safe, filling pieces may be removed so that cable sets can be inserted in the cable feed openings (see illustration). These filling pieces must then be replaced after the cables have been laid. The cable exit points in the floor must be kept clear to ensure that the cables are not bent or damaged.

Make sure that the cables provided on-site are long enough to be laid through the installation frame into the safe. Avoid excess lengths of cable by shortening them where necessary. You must ensure that connecting cables do not impede or actually damage any moving components.

44

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Power and data cables

1 Cable feed opening

No power or data cables may be installed below the CMD-V4. You will also find the position of the cable feed opening for the device in the section "Installation frame".

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

45

Power and data cables

Planning the Installation

Power supply
The device must only be connected to a TN system. In addition to the power supply for the device, grounding outlets must be provided by the customer for supplementary equipment such as a modem.

3 4 L N PE

1 2 3 4

Fuse or automatic circuit-breaker Connection for ProCash 2000xe / 2000xe USB Modem connection Connection of miscellaneous equipment

Remote status indicator


The optional remote status indicator comes with a 50 m (164.1 ft) connecting cable. During planning, the position for installation and cable routing must be defined (see also chapter "Installing the remote status indicator").

46

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Dimensions of the frame logo

Camera connection
If, on devices with a portrait camera and/or cash slot camera integrated in the factory, the images supplied are to be processed outside the device, the following cables must be planned on the construction side in addition to the requisite power and data cable connections: 1 video cable 75 with BNC connector per deployed camera 1 V.24 control cable for camera surveillance The interfaces for the camera connection are located in the safe. The cable is fed in through the cable feed opening of the safe.

Dimensions of the frame logo

If the ProCash 2000xe / 2000xe USB was ordered without a logo, the logo has to be provided by the customer. The illustration shows the visible outer surface (554 mm x 170 mm - 21.81" x 6.69"). The actual dimensions are 565 mm x 176 mm (22.24" x 6.93"). For the dimensions of the device logo please refer to the operating manual of the device.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

47

Transport path requirements

Planning the Installation

Transport path requirements


The device is equipped with a shipping crate and can be transported with a pallet lift truck. The forks of the truck must be pushed as far as possible underneath the device from the side of the safe door. The entire transportation route, like the installation site, must be checked for load capacity and, if necessary, strengthened as appropriate before the installation date. In order to avoid damage at the floor covering, panels (e.g. beaverboard) should be laid on the floor for the transport with a lift truck. Observe the ambient condition requirements in the chapter "Appendix", section "Technical data" for transportation and storage. Due to the shipping crate some dimensions are different (see illustration below).

48

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Planning the Installation

Transport path requirements

600 (23.62")

145 (5.71") 1592 / 1732* (62.68" / 68.19"*)

1420 (55.91")

690 (27.17")

900 / 925*** (35.43" / 36.42"***) 1050 / 1075*** (41.34" / 42.32"***)

1 Shipping crate * Height of a device with 5-cassette dispenser ** On the rearload device the standard lock measures 43 mm (1.69") instead of max. 72 mm (2.83") of the customer-specific lock. *** Frontload devices with a customer-specific lock have a depth of 1075 mm (42.32").

845 (33.27")
49

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Transport path requirements

Planning the Installation

Check beforehand if there is enough space to move the device through doors and hallways. The following illustration should help you determine if the space is sufficient. It shows the device on a standard lift truck. With the help of the grid (100 mm x 100 mm (3.94" x 3.94")) you can draw the actual dimensions of the door and the hallway to find out if there is enough space for transportation. Refer to the next page for an example.

1350 (53.15") 1400 (55.12")

50

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

520 (20.47") 690 (27.17")

Planning the Installation

Transport path requirements

Example with minimum transport path measurements

710 (27.95")

1900 (74.8")

1350 (53.15") 1400 (55.12")

520 (20.47") 690 (27.17")


ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

51

Transport path requirements

Planning the Installation

52

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation
This chapter describes the individual steps to be taken to install the device.

All dimensions are specified in millimeters (inches). The figures are not drawn to scale. Contact the person in charge of planning the installation to verify that all preparatory work has been done completely and correctly and that none of the required power and data cables are missing.

Removing the packaging



Remove the packing material of the ProCash 2000xe / 2000xe USB. Dispose of the packaging which is no longer needed according to the regulations of your country.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

53

Removing the shipping crate

Installation

Removing the shipping crate


General
For transportation the device is equipped with a shipping crate which must be removed prior to the installation.

To move the device push against the sides of its body only as shown in the illustration below.

54

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Removing the shipping crate

Removing the shipping crate


Proceed as follows to remove the shipping crate: Remove the screws of the shipping crate from underneath. Lift the device. Remove the shipping crate of the ProCash 2000xe / 2000xe USB (1).

Dispose of the shipping crate which is no longer needed according to the regulations of your country.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

55

Mounting sets

Installation

Mounting sets
i
The mounting sets are supplied with the installation frame of the ProCash 2000xe / 2000xe USB. The mounting set for the tear-off sensor is not supplied with the device.

Mounting set for standard frame 01750006706


i
If the mounting set is not provided, use equivalent fastening material. The procedure for mounting the installation frame or the installation rack described in the sections of the installation versions assumes that the provided mounting set is used. If you are using different fastening materials please follow the instructions included with those items. Quantity required 1

Item Caulking cartridge A caulking gun is not included in the delivery package. Threaded rod M16 x 200 (5.51") (DIN 976, property class 8.8) Hexagon nut M16 (DIN 934-8) Washer A 17 DIN 125-St

4 4 4

56

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Mounting sets

Mounting set 01750051579 for CEN frame


i
If the mounting set is not provided, use equivalent fastening material. The procedure for mounting the installation frame or the installation rack described in the sections of the installation versions assumes that the provided mounting set is used. If you are using different fastening materials please follow the instructions included with those items. Item
Caulking cartridge

Quantity required 1

A caulking gun is not included in the delivery package. Threaded rod M16 x 200 (DIN 976, property class 10.9) Hexagon nut M16 (DIN 934-10.9) Washer A 17 DIN 125-St

4 4 4

Mounting set 01750078516 (for UL/CEN L safe) on installation frame


Item
Pan head screw M16 x 40

Quantity required 4 4

(ISO 4762, property class 10.9)


Washer A 17 ISO 7089-St

Mounting set 01750051578 (for CEN III/CEN IV safe) on installation frame


Item
Pan head screw M16 x 45

Quantity required 4 4

(ISO 4762, property class 10.9)


Washer A 17 ISO 7089-St

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

57

Overview of installation types

Installation

Overview of installation types


Installation options Frontload with 4-cassette dispenser yes Rearload with 4-cassette dispenser yes Rearload with 5-cassette dispenser yes

Installation without frame (see p. 59) Installation with frame for complete integration (see p. 69) Installation with window frame (see p. 88) Installation with frame for partial integration with light box (see p. 108) Installation with frame for partial integration without light box (see p. 128)

no no

yes yes

no yes

yes

yes

no

yes

yes

no

Observe the space required for operation and maintenance for the different installation options (see chapter "Planning the Installation", section "Space required for operation and maintenance "). For installation with a frame the device must have been prepared for this type of installation in the factory when it is shipped.

58

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation without frame

Installation without frame


The device can either be installed free-standing, in front of a wall or in a niche.

Installing the installation frame


i
Observe the specified maintenance space when positioning the device and the installation frame (see chapter "Planning the Installation", section "Space required for operation and maintenance"). Make sure that the clearance between the vents and the wall is at least 50 mm (1.97") (53 mm (2.09") in relation to the installation frame).

Align the installation frame and mark the holes to be drilled for mounting the installation frame (see illustration below).

If a tear-off sensor is to be installed as agreed with the financial institution or the alarm technician, also mark the holes for the tear-off sensor (see illustrations below).

Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type (UL, CEN L, CEN III, CEN IV). These attachment points are at position (2) and the alternative attachment points are at position (3) (see illustration below). The supplied installation frame can be used for the frontload and rearload versions.

If the mounting set is not provided, use equivalent fastening material.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

59

Installation without frame

Installation

The installation frame must be secured using one threaded rod per group of holes A to D. The installation frame is secured with four threaded rods.

1 2 A 3 B

4 7 5 8 3
C

D 2 1
9

1 2 3 4 5 6 7 8 9

Attachment points of safe Attachment points of installation frame Alternative attachment points of installation frame Attachment point of tear-off sensor Rearload Attachment point of tear-off sensor Frontload Cable lead-ins into the installation frame Area for cables Cable feed openings underneath the installation frame This side must always point towards the customer panel

60

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation without frame

Drill the required four holes and the hole for the tear-off sensor, if necessary (see following figure).

Installation on raised or cavity flooring as well as on a floating floor is not permissible according to the CEN standard. If the mounting structure differs from the one described below (see illustration below), it must be approved by the insurer. To ensure that the safe does not become detached, the threaded rods of the installation frame must be fastened in the concrete foundation. The drilled holes in the concrete foundation must have a depth of at least 125 mm (4.92") for the installation frame (see illustration below). For the hole diameter please refer to the mounting instructions of the caulking cartridge. The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustration below). Consult your alarm technician about the size of the hole and the fixing.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

61

Installation without frame Mounting structure

Installation

min. 40 (1.57")

1 2 3 4

Safe Mounting set for safe Tear-off sensor Installation frame

5 6 7 8

Screed Concrete Mounting set for installation frame Top surface of finished floor

* This measure is required if the threaded rods included in the delivery


package are used unmodified. For a different measure the threaded rods must be modified or replaced by equivalent ones.

Clean the drill holes as specified in the mounting instructions of the caulking cartridge. Secure the threaded rods in the concrete foundation as specified in the mounting instructions of the caulking cartridge.

The threaded rods must protrude at a minimum 24 mm (0.94") and at a maximum 25 mm (0.98").

Insert the fixing for the tear-off sensor if required.

62

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

min. 125 (4.92") 176* (6.93"*)

25 (0.98")

UL CEN

Installation

Installation without frame

Remove the filling piece 6b (rearload) or 6a (frontload) and possibly the filling piece 6a (rearload) or 6b (frontload) from the cable lead-ins in the upper part of the installation rack (see positions 6a and 6b in the following illustration (example shows rearload version)).

The space inside the installation frame allows cable lead-in through cable ducts in the floor. If the connecting cables on the site are not located on the safe door side: Insert the data lines, the connecting cable of the remote status indicator (optional) and the power cord through the cable lead-ins and if necessary through the cable feed openings behind the safe door side (11) of the installation frame, as in the example shown here. Make sure that the connecting cables are laid loosely and are not crushed by the installation frame.

11

6b

6a

Screw the installation frame to the floor (for material see section "Mounting sets"). If applicable, note the hardening times of the mounting material.

The threaded rods must not protrude beyond the installation frame. If necessary, level the threaded rods.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

63

Installation without frame

Installation

Mounting the device on the installation frame


Push the device on the installation frame. Ensure that no cables are damaged in the process. Open the safe door (see chapter "Basic Operation" in the operating manual). If it is necessary for the installation remove those parts inside the unit which secure its components during transportation (see enclosed information sheet). Pull out the CMD-V4 (see chapter "Basic Operation" in the operating manual).

To facilitate access to the attachment points of the safe you can swing the cash media dispenser (CMD-V4) up.

Lifting the cash media dispenser (CMD-V4) up


Put the two track stops (1) (to be found in the safe) in place as shown in the illustration. Remove the reject/retract cassette and the cash-out cassettes (3) (see chapter "Cash Media Dispenser (CMD-V4)" in the operating manual). To reduce the weight, remove all cassettes. Remove the securing screw (2) at the end of the pull-out track, one each on the right and on the left side.

When lifting the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around!

64

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation without frame Swing the CMD-V4 (1) up until the hole (2) above the pull-out tracks is visible. Push the locking axle (3) (to be found in the safe) in until the grooves are in line with the side panels of the CMD-V4 rack. Check the firm fit of the CMD-V4 by moving it slightly back and forth. When mounting the locking axle ensure that no cables are damaged in the process. Check the CMD-V4 for a secure fit. The locking axle must be firmly in place.

Screwing the device on the installation frame


Place the device on the installation frame and align it (for attachment points (1) and (2) please refer to the illustration) and fasten the safe to the installation frame with screws (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

65

Installation without frame

Installation

Pushing the cash media dispenser (CMD-V4) down


Lift the CMD-V4 slightly (1) until you may remove the locking axle from the hole (2) in the direction of the arrow (3). Carefully lower the CMD-V4.

When lowering the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around!

Mount both securing screws. Remove the two track locks and push the CMD-V4 back into the device. Replace the cassettes.

66

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation without frame

Installing the power and data cables in the device


Remove the filling piece of the safe.

Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation frame. If necessary, replace the filling piece of the installation frame (position 6b (rearload) or position 6a (frontload)) and the filling piece of the safe.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

67

Installation without frame

Installation

Further procedure for CEN installation

Attach the VDS label for the installation frame inside the safe door below the existing VDS label. (The VDS label for the mounted installation frame is included with the installation frame.) After mounting the installation frame and the device, fill out the Confirmation of Installation. (The Confirmation of Installation is included with the installation frame.) Fax the filled out and signed Confirmation of Installation form to the fax number provided on the form.

If there is no fax machine available, the form has to be faxed to this number at a later point in time.

Give the Confirmation of Installation to the operator of the device.

The operator needs the Confirmation of Installation for submitting it to the insurance company.

General

Close the device.

The locking axle and the track stops must remain in the safe for later service operations.

68

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for complete integration

Installation with frame for complete integration


Mounting the installation frame
i
Observe the specified maintenance space when positioning the device and the installation frame (see chapter "Planning the Installation", section "Space required for operation and maintenance"). Make sure that the clearance between the vents and the wall is at least 50 mm (1.97") (53 mm (2.09") in relation to the installation frame).

Align the installation frame and mark the holes to be drilled for mounting the installation frame (see illustration below).

If a tear-off sensor is to be installed as agreed with the financial institution or the alarm technician, also mark the holes for the tear-off sensor (see illustrations below).

Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type (UL, CEN L, CEN III, CEN IV). These attachment points are at position (2) and the alternative attachment points are at position (3) (see illustration below).

If the mounting set is not provided, use equivalent fastening material.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

69

Installation with frame for complete integration

Installation

The installation frame must be secured using one threaded rod per group of holes A to D. The installation frame is secured with four threaded rods.

11 1 2 6

4 7 5 8

B
6 10

D
28 (1.1") 10

2 1 23 (0.91") 9 640 (25.2") 6 23 (0.91")

1 Attachment points of safe 2 Attachment points of installation frame 3 Alternative attachment points of installation frame 4 Attachment point of tear-off sensor Rearload 5 Not used

6 Cable lead-ins into the installation frame 7 Area for cables 8 Cable feed openings underneath the installation frame 9 Customer panel side 10 Wall 11 Side with safe door

70

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

max. 360 (max. 14.17")

Installation

Installation with frame for complete integration

Drill the required four holes and the hole for the tear-off sensor, if necessary (see following figure).

Installation on raised or cavity flooring as well as on a floating floor is not permissible according to the CEN standard. If the mounting structure differs from the one described below (see illustration below), it must be approved by the insurer. To ensure that the safe does not become detached, the threaded rods of the installation frame must be fastened in the concrete foundation. The drilled holes in the concrete foundation must have a depth of at least 125 mm (4.92") for the installation frame (see illustration below). For the hole diameter please refer to the mounting instructions of the caulking cartridge. The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustration below). Consult your alarm technician about the size of the hole and the fixing.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

71

Installation with frame for complete integration Mounting structure

Installation

min. 40 (1.57")

1 2 3 4

Safe Mounting set for safe Tear-off sensor Installation frame

5 6 7 8

Screed Concrete Mounting set for installation frame Top surface of finished floor

* This measure is required if the threaded rods included in the delivery


package are used unmodified. For a different measure the threaded rods must be modified or replaced by equivalent ones.

Clean the drill holes as specified in the mounting instructions of the caulking cartridge. Secure the threaded rods in the concrete foundation as specified in the mounting instructions of the caulking cartridge.

The threaded rods must protrude at a minimum 24 mm (0.94") and at a maximum 25 mm (0.98").

Insert the fixing for the tear-off sensor if required.

72

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

min. 125 (4.92") 176* (6.93"*)

25 (0.98")

UL CEN

Installation

Installation with frame for complete integration

Remove the filling piece 6b and possibly 6a from the cable lead-ins (see positions 6a and 6b in the following illustration).

The space inside the installation frame allows cable lead-in through cable ducts in the floor. If the connecting cables on the site are not located on the safe door side: Insert the data lines, the connecting cable of the remote status indicator (optional) and the power cord through the cable lead-ins and if necessary through the cable feed openings behind the safe door side (11) of the installation frame, as in the example shown here. Make sure that the connecting cables are laid loosely and are not crushed by the installation frame.

11

6b

6a

Screw the installation frame to the floor (for material see section "Mounting sets"). If applicable, note the hardening times of the mounting material.

The threaded rods must not protrude beyond the installation frame. If necessary, level the threaded rods.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

73

Installation with frame for complete integration

Installation

Mounting the device on the installation frame


i
Before the frame can be mounted, certain steps are required for systems which have not been prepared for frame installation in the factory (please refer to the mounting instructions supplied with the frame). Remove the blind plugs in positions (1) and (2) on both sides of the device by levering them up from the side (3) and pulling them out forwards (4).

Push the device on the installation frame. Ensure that no cables are damaged in the process. Open the safe door (see chapter "Basic Operation" in the operating manual). If it is necessary for the installation remove those parts inside the unit which secure its components during transportation (see enclosed information sheet). Pull out the CMD-V4 (see chapter "Basic Operation" in the operating manual).

To facilitate access to the attachment points of the safe you can swing the cash media dispenser (CMD-V4) up.

74

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for complete integration

Lifting the cash media dispenser (CMD-V4) up


Put the two track stops (1) (to be found in the safe) in place as shown in the illustration. Remove the reject/retract cassette and the cash-out cassettes (3) (see chapter "Cash Media Dispenser (CMD-V4)" in the operating manual). To reduce the weight, remove all cassettes. Remove the securing screw (2) at the end of the pull-out track, one each on the right and on the left side.

When lifting the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around! Swing the CMD-V4 (1) up until the hole (2) above the pull-out tracks is visible. Push the locking axle (3) (to be found in the safe) in until the grooves are in line with the side panels of the CMD-V4 rack. Check the firm fit of the CMD-V4 by moving it slightly back and forth. When mounting the locking axle ensure that no cables are damaged in the process. Check the CMD-V4 for a secure fit. The locking axle must be firmly in place.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

75

Installation with frame for complete integration

Installation

Screwing the device on the installation frame


Place the device on the installation frame and align it (for attachment points (1) and (2) please refer to the illustration) and fasten the safe to the installation frame with screws (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe.

Pushing the cash media dispenser (CMD-V4) down


Lift the CMD-V4 slightly (1) until you may remove the locking axle from the hole (2) in the direction of the arrow (3). Carefully lower the CMD-V4.

When lowering the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around!

Mount both securing screws. Remove the two track locks and push the CMD-V4 back into the device. Replace the cassettes.

76

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for complete integration

Installing the power and data cables in the device


Remove the filling piece of the safe.

Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation frame. Replace the filling piece of the installation frame (position 6b) and the filling piece of the safe.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

77

Installation with frame for complete integration

Installation

Further procedure for CEN installation

Attach the VDS label for the installation frame inside the safe door below the existing VDS label. (The VDS label for the mounted installation frame is included with the installation frame.) After mounting the installation frame and the device, fill out the Confirmation of Installation. (The Confirmation of Installation is included with the installation frame.) Fax the filled out and signed Confirmation of Installation form to the fax number provided on the form.

If there is no fax machine available, the form has to be faxed to this number at a later point in time.

Give the Confirmation of Installation to the operator of the device.

The operator needs the Confirmation of Installation for submitting it to the insurance company.

General

Close the device. Unpack the parts of the installation frame and install them (see section below "Installing frame for complete integration in wall").

The locking axle and the track stops must remain in the safe for later service operations.

78

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for complete integration

Installing frame for complete integration in wall


View of the frame (completely assembled)

6 1

7 2

4 5

1 Frame 2 Cover (installed only after frame has been attached to the device) 3 Connecting plate 4 Left frame extension

5 Right frame extension 6 Holes for attaching the frame to the wall 7 Light cable 8 Frame bracket

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

79

Installation with frame for complete integration

Installation

Pre-assembling the frame

Attach the frame extensions (items 4 and 5 in the illustration "View of the frame (completely assembled)") on the left and right side as shown in the illustration below using two ratchet washers M4 (1).

4x

Attach the connecting plates (item 3 in the illustration "View of the frame (completely assembled)") on the left and on the right side using one Taptite round head screw M4x6 each (2).

2x

80

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for complete integration

Attach the center frame brackets (item 8 in the illustration "View of the frame (completely assembled)") on the left and on the right side using two Taptite round head screws M4x6 each (3).

4x

Attach the bottom frame brackets (item 8 in the illustration "View of the frame (completely assembled)") on the left and on the right side using two Taptite round head screws M4x6 each (4).

4x

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

81

Installation with frame for complete integration

Installation

Mounting the frame

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB).

Feed the connecting cable for the light through the cable opening into the device (1). Push the frame from the front in the direction of the arrow (2) up to the customer panel. Lift the frame a little and slide it carefully over the customer panel and let go.

Be careful not to scratch the customer panel.

Push the frame against the wall.

82

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for complete integration

4x

Attach the frame brackets (1) on the side to the device using one pan head screw with inner hexagon M6x10 and a washer 6.4x1.6.

If space is restricted use an appropriate tool that is short enough. When tightening the screws of the frame brackets, make sure that the frame is touching the wall. However, if the wall is uneven, you must not use force to press it in, since the frame could distort when you secure the frame tabs. This could cause the customer panel to grate or jam against the inside of the frame when you open it.

Push the customer panel back in until it engages. Close the door of the operating unit.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

83

Installation with frame for complete integration

Installation

Release the locking pins by pushing them slightly sideways with a screwdriver and turning them (1) until they jump out (2).

1
Lower the light box pane (3).

1 3

Drill a 50 mm (1.97") deep hole with a diameter of 8 mm (0.31") through each of the three holes (1). Use the supplied fixings and screws 6x40 to attach the frame to the wall.

Close the light box by following the same steps in reverse order.

84

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for complete integration

Connecting the light

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB).

The connecting cable for the logo light is lying rolled up inside the device next to the PC.

Attach the plugs to the adapter cable. The cable is located on the crossbar of the cover in the device. Affix the cable to the device in such a way that it will not be damaged when the customer panel is pulled out. Push the customer panel back in until it engages. Close the door of the operating unit.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

85

Installation with frame for complete integration

Installation

Adjusting the cover

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB).

2 3 1

Loosen the three screws (1) at the rear of the device. At the positions marked (3) push one screw M4x6 each through the device cover. Loosely attach the wedge-shaped cover to the device cover (2) with the screws from inside. Push the customer panel back in until it engages.

86

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for complete integration Adjust the wedge-shaped cover (2) from the front of the device. Ideally, the clearance between the cover and the customer panel's top edge should be approx. 2 mm (0.08").

Tighten the three screws (1) at the rear of the device. Release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB). Fasten the wedge-shaped cover using the three screws (3) from inside. Push the customer panel back in until it engages. Close the door of the operating unit.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

87

Installation with window frame

Installation

Installation with window frame


Mounting the installation frame
i
Observe the specified maintenance space when positioning the device and the installation frame (see chapter "Planning the Installation", section "Space required for operation and maintenance"). Make sure that the clearance between the vents and the wall is at least 50 mm (1.97") (53 mm (2.09") in relation to the installation frame).

Align the installation frame and mark the holes to be drilled for mounting the installation frame (see illustration below).

If a tear-off sensor is to be installed as agreed with the financial institution or the alarm technician, also mark the holes for the tear-off sensor (see illustrations below).

Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type (UL, CEN L, CEN III, CEN IV). These attachment points are at position (2) and the alternative attachment points are at position (3) (see illustration below).

If the mounting set is not provided, use equivalent fastening material.

88

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with window frame

Position of the installation frame with a maximum wall thickness of 50 mm (1.97")

The installation frame must be secured using one threaded rod per group of holes A to D. The installation frame is secured with four threaded rods.

11

1 2

A 3

7 8 60 (2.36") 3 C 1 2 D

4 5

10

10

9
max. 50 (max. 1.97")

23 (0.91")

9 640 (25.2")

23 (0.91")

1 Attachment points of safe 2 Attachment points of installation frame 3 Alternative attachment points of installation frame 4 Attachment point of tear-off sensor Rearload 5 Not used

6 Cable lead-ins into the installation frame 7 Area for cables 8 Cable feed openings underneath installation frame 9 Customer panel side 10 Wall 11 Side with safe door

max. 360 (max. 14.17")


89

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Installation with window frame

Installation

Position of the installation frame with a maximum wall thickness of 160 mm (6.3")

The installation frame must be secured using one threaded rod per group of holes A to D. The installation frame is secured with four threaded rods.

11

1 2

A 3

5 8 170 (6.69") 3 C 1 2 10 D

max. 160 (max. 6.3")


01750058375 G

10

23 (0.91")

640 (25.2")

23 (0.91")

1 Attachment points of safe 2 Attachment points of installation frame 3 Alternative attachment points of installation frame 4 Attachment point of tear-off sensor Rearload 5 Not used

6 Cable lead-ins into the installation frame 7 Area for cables 8 Cable feed openings underneath the installation frame 9 Customer panel side 10 Wall 11 Side with safe door

90

ProCash 2000xe / 2000xe USB - Installation Guide

max. 360 (max. 14.17")

Installation

Installation with window frame

Drill the required four holes and the hole for the tear-off sensor, if necessary (see following figure).

Installation on raised or cavity flooring as well as on a floating floor is not permissible according to the CEN standard. If the mounting structure differs from the one described below (see illustration below), it must be approved by the insurer. To ensure that the safe does not become detached, the threaded rods of the installation frame must be fastened in the concrete foundation. The drilled holes in the concrete foundation must have a depth of at least 125 mm (4.92") for the installation frame (see illustration below). For the hole diameter please refer to the mounting instructions of the caulking cartridge. The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustration below). Consult your alarm technician about the size of the hole and the fixing.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

91

Installation with window frame Mounting structure

Installation

min. 40 (1.57")

1 2 3 4

Safe Mounting set for safe Tear-off sensor Installation frame

5 6 7 8

Screed Concrete Mounting set for installation frame Top surface of finished floor

* This measure is required if the threaded rods included in the delivery


package are used unmodified. For a different measure the threaded rods must be modified or replaced by equivalent ones.

Clean the drill holes as specified in the mounting instructions of the caulking cartridge. Secure the threaded rods in the concrete foundation as specified in the mounting instructions of the caulking cartridge.

The threaded rods must protrude at a minimum 24 mm (0.94") and at a maximum 25 mm (0.98").

Insert the fixing for the tear-off sensor if required.

92

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

min. 125 (4.92") 176* (6.93"*)

25 (0.98")

UL CEN

Installation

Installation with window frame

Remove the filling piece 6b and possibly 6a from the cable lead-ins (see positions 6a and 6b in the following illustration).

The space inside the installation frame allows cable lead-in through cable ducts in the floor. If the connecting cables on the site are not located on the safe door side: Insert the data lines, the connecting cable of the remote status indicator (optional) and the power cord through the cable lead-ins and if necessary through the cable feed openings behind the safe door side (11) of the installation frame, as in the example shown here. Make sure that the connecting cables are laid loosely and are not crushed by the installation frame.

11

6b

6a

Screw the installation frame to the floor (for material see section "Mounting sets"). If applicable, note the hardening times of the mounting material.

The threaded rods must not protrude beyond the installation frame. If necessary, level the threaded rods.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

93

Installation with window frame

Installation

Mounting the device on the installation frame


i
Before the frame can be mounted, certain steps are required for systems which have not been prepared for frame installation in the factory (please refer to the mounting instructions supplied with the frame). Remove the blind plugs in positions (1) and (2) on both sides of the device by levering them up from the side (3) and pulling them out forwards (4).

Push the device on the installation frame. Ensure that no cables are damaged in the process. Open the safe door (see chapter "Basic Operation" in the operating manual). If it is necessary for the installation remove those parts inside the unit which secure its components during transportation (see enclosed information sheet). Pull out the CMD-V4 (see chapter "Basic Operation" in the operating manual).

To facilitate access to the attachment points of the safe you can swing the cash media dispenser (CMD-V4) up.

94

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with window frame

Lifting the cash media dispenser (CMD-V4) up


Put the two track stops (1) (to be found in the safe) in place as shown in the illustration. Remove the reject/retract cassette and the cash-out cassettes (3) (see chapter "Cash Media Dispenser (CMD-V4)" in the operating manual). To reduce the weight, remove all cassettes. Remove the securing screw (2) at the end of the pull-out track, one each on the right and on the left side.

When lifting the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around! Swing the CMD-V4 (1) up until the hole (2) above the pull-out tracks is visible. Push the locking axle (3) (to be found in the safe) in until the grooves are in line with the side panels of the CMD-V4 rack. Check the firm fit of the CMD-V4 by moving it slightly back and forth. When mounting the locking axle ensure that no cables are damaged in the process. Check the CMD-V4 for a secure fit. The locking axle must be firmly in place.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

95

Installation with window frame

Installation

Screwing the device on the installation frame


Place the device on the installation frame and align it (for attachment points (1) and (2) please refer to the illustration) and fasten the safe to the installation frame with screws (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe.

Pushing the cash media dispenser (CMD-V4) down


Lift the CMD-V4 slightly (1) until you may remove the locking axle from the hole (2) in the direction of the arrow (3). Carefully lower the CMD-V4.

When lowering the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around!

Mount both securing screws. Remove the two track locks and push the CMD-V4 back into the device. Replace the cassettes.

96

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with window frame

Installing the power and data cables in the device


Remove the filling piece of the safe.

Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation frame. Replace the filling piece of the installation frame (position 6b) and the filling piece of the safe.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

97

Installation with window frame

Installation

Further procedure for CEN installation

Attach the VDS label for the installation frame inside the safe door below the existing VDS label. (The VDS label for the mounted installation frame is included with the installation frame.) After mounting the installation frame and the device, fill out the Confirmation of Installation. (The Confirmation of Installation is included with the installation frame.) Fax the filled out and signed Confirmation of Installation form to the fax number provided on the form.

If there is no fax machine available, the form has to be faxed to this number at a later point in time.

Give the Confirmation of Installation to the operator of the device.

The operator needs the Confirmation of Installation for submitting it to the insurance company.

General

Close the device. Unpack the parts of the installation frame and install them (see section "Installing the window frame").

The locking axle and the track stops must remain in the safe for later service operations.

98

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with window frame

Installing the window frame


View of the frame for up to 50 mm (1.97") thick walls (completely assembled)
1

2 3

1 Holes for attaching the frame to the wall 2 Frame 3 Cover (installed only after the frame has been attached to the device)

4 Light cable 5 Window crossbar 6 Frame brackets

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

99

Installation with window frame

Installation

View of the frame for up to 160 mm (6.3") thick walls (completely assembled)
1

2 3

1 Holes for attaching the frame to the wall 2 Frame 3 Cover (installed only after the frame has been attached to the device)

4 Light cable 5 Window crossbar 6 Frame brackets

100

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with window frame

Pre-assembling the frame for up to 50 mm (1.97") and 160 mm (6.30") thick walls

In the following pre-assembly of the frame is described using the window frame for up 160 mm (6.30") thick walls as an example. The procedure for pre-assembling a window frame for up to 50 mm (1.97") thick walls is the same.

Attach the frame brackets (item 6 in the illustration "View of the frame for up to 160 mm (6.30") thick walls (completely assembled)" or "View of the frame for up to 50 mm (1.97") thick walls (completely assembled)") on the left and on the right side using two Taptite round head screws M4x6 (1) each.

4x

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

101

Installation with window frame

Installation

Mounting the frame

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB).

Feed the connecting cable for the light through the cable opening into the device (1). Push the frame from the front in the direction of the arrow (2) up to the customer panel. Lift the frame a little and slide it carefully over the customer panel and let go.

Be careful not to scratch the customer panel.

Push the frame against the wall.

102

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with window frame

2x

Attach the frame brackets (1) to the device using one pan head screw with inner hexagon M6x10 and a washer 6.4x1.6.

If space is restricted use an appropriate tool that is short enough. When tightening the screws of the frame brackets, make sure that the frame is touching the wall. However, if the wall is uneven, you must not use force to press it in, since the frame could distort when you secure the frame tabs. This could cause the customer panel to grate or jam against the inside of the frame when you open it.

Push the customer panel back in until it engages. Close the door of the operating unit.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

103

Installation with window frame

Installation Release the locking pins by pushing them slightly sideways with a screwdriver and turning them (1) until they jump out (2).

1
Lower the light box pane (3).

1 3

Drill a 50 mm (1.97") deep hole with a diameter of 8 mm (0.31") through each of the three holes (1). Use the supplied fixings and screws 6x40 to attach the frame to the wall.

Close the light box by following the same steps in reverse order.

104

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with window frame

Connecting the light on frames for up to 50 mm (1.97") and 160 mm (6.30") thick walls

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB).

The connecting cable for the logo light is lying rolled up inside the device next to the PC.

Attach the plugs to the adapter cable. The cable is located on the crossbar of the cover in the device. Affix the cable to the device in such a way that it will not be damaged when the customer panel is pulled out. Push the customer panel back in until it engages. Close the door of the operating unit.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

105

Installation with window frame

Installation

Adjusting the cover for frames for up to 50 mm (1.97") and 160 mm (6.30") thick walls
Frame for up to 50 mm (1.97") thick walls Frame for up to 160 mm (6.30") thick walls

2 3 1
1

2 3

Loosen the three screws (1) at the rear of the device. At the positions marked (3) push one screw M4x6 each through the device cover. Loosely attach the wedge-shaped cover to the device cover (2) with the screws from inside. Push the customer panel back in until it engages.

106

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Frame for up to 50 mm (1.97") thick walls

Installation with window frame Frame for up to 160 mm (6.30") thick walls

Adjust the wedge-shaped cover (2) from the front of the device.

Ideally, the clearance between the cover and the customer panel's top edge should be approx. 2 mm (0.08").

Tighten the three screws (1) at the rear of the device. Release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB). Fasten the wedge-shaped cover using the three screws (3) from inside. Push the customer panel back in until it engages. Close the door of the operating unit.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

107

Installation with frame for partial integration with light box

Installation

Installation with frame for partial integration with light box


Installing the installation frame
i
Observe the specified maintenance space when positioning the device and the installation frame (see chapter "Planning the Installation", section "Space required for operation and maintenance"). Make sure that the clearance between the vents and the wall is at least 50 mm (1.97") (53 mm (2.09") in relation to the installation frame).

Align the installation frame and mark the holes to be drilled for mounting the installation frame (see illustration below).

If a tear-off sensor is to be installed as agreed with the financial institution or the alarm technician, also mark the holes for the tear-off sensor (see illustrations below).

Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type (UL, CEN L, CEN III, CEN IV). These attachment points are at position (2) and the alternative attachment points are at position (3) (see illustration below). The supplied installation frame can be used for the frontload and rearload versions.

If the mounting set is not provided, use equivalent fastening material.

108

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box

The installation frame must be secured using one threaded rod per group of holes A to D. The installation frame is secured with four threaded rods.

1 2 4

5 7
max. 360 (max. 14.17") 160 (6.3") 23 (0.91")
6 Cable lead-ins into the installation frame 7 Area for cables 8 Cable feed openings underneath the installation frame 9 This side must always point towards the customer panel 10 Wall 109

12 10

12 10

2 1
23 (0.91") 640 (25.2")

1 Attachment points of safe 2 Attachment points of installation frame 3 Alternative attachment points of installation frame 4 Attachment point of tear-off sensor Rearload 5 Attachment point of tear-off sensor Frontload

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Installation with frame for partial integration with light box

Installation

Drill the required four holes and the hole for the tear-off sensor, if necessary (see following figure).

Installation on raised or cavity flooring as well as on a floating floor is not permissible according to the CEN standard. If the mounting structure differs from the one described below (see illustration below), it must be approved by the insurer. To ensure that the safe does not become detached, the threaded rods of the installation frame must be fastened in the concrete foundation. The drilled holes in the concrete foundation must have a depth of at least 125 mm (4.92") for the installation frame (see illustration below). For the hole diameter please refer to the mounting instructions of the caulking cartridge. The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustration below). Consult your alarm technician about the size of the hole and the fixing.

110

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box

Mounting structure
UL CEN

7 25

8 176*
111

min. 40

1 2 3 4

Safe Mounting set for safe Tear-off sensor Installation frame

5 6 7 8

Screed Concrete Mounting set for installation frame Top surface of finished floor

* This measure is required if the threaded rods included in the delivery


package are used unmodified. For a different measure the threaded rods must be modified or replaced by equivalent ones.

Clean the drill holes as specified in the mounting instructions of the caulking cartridge. Secure the threaded rods in the concrete foundation as specified in the mounting instructions of the caulking cartridge.

The threaded rods must protrude at a minimum 24 mm (0.94") and at a maximum 25 mm (0.98").

Insert the fixing for the tear-off sensor if required.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

min. 125

Installation with frame for partial integration with light box

Installation

Remove the filling piece 6b (rearload) or 6a (frontload) and possibly the filling piece 6a (rearload) or 6b (frontload) from the cable lead-ins in the upper part of the installation rack (see positions 6a and 6b in the following illustration (example shows rearload version)).

The space inside the installation frame allows cable lead-in through cable ducts in the floor. If the connecting cables on the site are not located on the safe door side: Insert the data lines, the connecting cable of the remote status indicator (optional) and the power cord through the cable lead-ins and if necessary through the cable feed openings behind the safe door side (11) of the installation frame, as in the example shown here. Make sure that the connecting cables are laid loosely and are not crushed by the installation frame.

11

6b

6a

Screw the installation frame to the floor (for material see section "Mounting sets"). If applicable, note the hardening times of the mounting material.

The threaded rods must not protrude beyond the installation frame. If necessary, level the threaded rods.

112

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box

Mounting the device on the installation frame


i
Before the frame can be mounted, certain steps are required for systems which have not been prepared for frame installation in the factory (please refer to the mounting instructions supplied with the frame). Remove the blind plugs in positions (1) on both sides of the device by levering them up from the side (2) and pulling them out forwards (3).

Push the device on the installation frame. Ensure that no cables are damaged in the process. Open the safe door (see chapter "Basic Operation" in the operating manual). If it is necessary for the installation remove those parts inside the unit which secure its components during transportation (see enclosed information sheet). Pull out the CMD-V4 (see chapter "Basic Operation" in the operating manual).

To facilitate access to the attachment points of the safe you can swing the cash media dispenser (CMD-V4) up.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

113

Installation with frame for partial integration with light box

Installation

Lifting the cash media dispenser (CMD-V4) up


Put the two track stops (1) (to be found in the safe) in place as shown in the illustration. Remove the reject/retract cassette and the cash-out cassettes (3) (see chapter "Cash Media Dispenser (CMD-V4)" in the operating manual). To reduce the weight, remove all cassettes. Remove the securing screw (2) at the end of the pull-out track, one each on the right and on the left side.

When lifting the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around! Swing the CMD-V4 (1) up until the hole (2) above the pull-out tracks is visible. Push the locking axle (3) (to be found in the safe) in until the grooves are in line with the side panels of the CMD-V4 rack. Check the firm fit of the CMD-V4 by moving it slightly back and forth. When mounting the locking axle ensure that no cables are damaged in the process. Check the CMD-V4 for a secure fit. The locking axle must be firmly in place.

114

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box

Screwing the device on the installation frame


Place the device on the installation frame and align it (for attachment points (1) and (2) please refer to the illustration) and fasten the safe to the installation frame with screws (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe.

Pushing the cash media dispenser (CMD-V4) down


Lift the CMD-V4 slightly (1) until you may remove the locking axle from the hole (2) in the direction of the arrow (3). Carefully lower the CMD-V4.

When lowering the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around!

Mount both securing screws. Remove the two track locks and push the CMD-V4 back into the device. Replace the cassettes.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

115

Installation with frame for partial integration with light box

Installation

Installing the power and data cables in the device


Remove the filling piece of the safe.

Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation frame. If necessary, replace the filling piece of the installation frame (position 6b (rearload) or position 6a (frontload)) and the filling piece of the safe.

116

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box

Further procedure for CEN installation

Attach the VDS label for the installation frame inside the safe door below the existing VDS label. (The VDS label for the mounted installation frame is included with the installation frame.) After mounting the installation frame and the device, fill out the Confirmation of Installation. (The Confirmation of Installation is included with the installation frame.) Fax the filled out and signed Confirmation of Installation form to the fax number provided on the form.

If there is no fax machine available, the form has to be faxed to this number at a later point in time.

Give the Confirmation of Installation to the operator of the device.

The operator needs the Confirmation of Installation for submitting it to the insurance company.

General

Close the device. Unpack the parts of the installation frame and install them (see section below "Installing the frame for partial integration with light box").

The locking axle and the track stops must remain in the safe for later service operations.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

117

Installation with frame for partial integration with light box

Installation

Installing the frame for partial integration with light box


View of the frame (completely assembled)

5 6 1 7

3 4

1 Cover (installed only after the frame has been attached to the device) 2 Connecting plate 3 Left frame extension 4 Right frame extension

5 Holes for attaching the frame to the wall 6 Frame 7 Light cable 8 Frame bracket

118

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box

Pre-assembling the frame

Attach the frame extensions (items 3 and 4 in the illustration "View of the frame (completely assembled)") on the left and right side as shown in the illustration below using two ratchet washers M4 (1).

4x

Attach the connecting plates (item 2 in the illustration "View of the frame (completely assembled)") on the left and on the right side using one Taptite round head screw M4x6 each (2).

2x

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

119

Installation with frame for partial integration with light box

Installation

Attach the center frame brackets (item 8 in the illustration "View of the frame (completely assembled)") on the left and on the right side using two Taptite round head screws M4x6 each (3).

4x

Attach the bottom frame brackets (item 8 in the illustration "View of the frame (completely assembled)") on the left and on the right side using two Taptite round head screws M4x6 each (4).

4x

120

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box

Mounting the frame

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB).

Push the frame from the front in the direction of the arrow (1) up to the customer panel. Lift the frame a little and slide it carefully over the customer panel and let go.

Be careful not to scratch the customer panel.

Push the frame against the wall.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

121

Installation with frame for partial integration with light box

Installation

4x

Attach the frame brackets (1) on the side to the device using one pan head screw with inner hexagon M6x10 and a washer 6.4x1.6.

If space is restricted use an appropriate tool that is short enough. When tightening the screws of the frame brackets, make sure that the frame is touching the wall. However, if the wall is uneven, you must not use force to press it in, since the frame could distort when you secure the frame tabs. This could cause the customer panel to grate or jam against the inside of the frame when you open it.

Push the customer panel back in until it engages. Close the door of the operating unit.

122

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box Release the locking pins by pushing them slightly sideways with a screwdriver and turning them (1) until they jump out (2).

1
Lower the light box pane (3).

1 3

Drill a 50 mm (1.97") deep hole with a diameter of 8 mm (0.31") through each of the three holes (1). Use the supplied fixings and screws 6x40 to attach the frame to the wall.

Close the light box by following the same steps in reverse order.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

123

Installation with frame for partial integration with light box

Installation

Connecting the light

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB). Feed the connecting cable for the light through the cable opening into the device (1).

The connecting cable for the logo light is lying rolled up inside the device next to the PC.

Attach the plugs to the adapter cable. The cable is located on the crossbar of the cover in the device. Affix the cable to the device in such a way that it will not be damaged when the customer panel is pulled out. Push the customer panel back in until it engages. Close the door of the operating unit.

124

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box

Adjusting the cover


Release the locking pins by pushing them slightly sideways with a screwdriver and turning them (1) until they jump out (2).

1
Lower the light box pane (3).

1 3

3x

Set the plate in the mounting (1) and fasten it using the three pan head screws M4x6 (2). Close the light box by following the same steps in reverse order.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

125

Installation with frame for partial integration with light box

Installation

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB).

3x

Insert the cover in the opening between device and frame in such a way that the guides of the retaining plate fit in the corresponding slots (3). Push the cover into a vertical position. At the positions marked (4) push one screw M4x6 each through the device cover. Loosely attach the cover to the device cover with the screws from inside. Push the customer panel back in until it engages.

126

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation

Installation with frame for partial integration with light box Adjust the cover from the front of the device. Ideally, the clearance between the cover and the customer panel's top edge should be approx. 2 mm (0.08").

Release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB). Fasten the cover using the three screws from inside. Push the customer panel back in until it engages. Close the door of the operating unit.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

127

Installation with frame for partial integration without light box Installation

Installation with frame for partial integration without light box


Mounting the installation frame
i
Observe the specified maintenance space when positioning the device and the installation frame (see chapter "Planning the Installation", section "Space required for operation and maintenance"). Make sure that the clearance between the vents and the wall is at least 50 mm (1.97") (53 mm (2.09") in relation to the installation frame).

Align the installation frame and mark the holes to be drilled for mounting the installation frame (see illustration below).

If a tear-off sensor is to be installed as agreed with the financial institution or the alarm technician, also mark the holes for the tear-off sensor (see illustrations below).

Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type (UL, CEN L, CEN III, CEN IV). These attachment points are at position (2) and the alternative attachment points are at position (3) (see illustration below). The supplied installation frame can be used for the frontload and rearload versions.

If the mounting set is not provided, use equivalent fastening material.

128

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Installation with frame for partial integration without light box

The installation frame must be secured using one threaded rod per group of holes A to D. The installation frame is secured with four threaded rods.

1 2 4

12 10
8

10

8 8
3

2 1 23 (0.91") 640 (25.2") 23 (0.91")

1 Attachment points of safe 2 Attachment points of installation frame 3 Alternative attachment points of installation frame 4 Attachment point of tear-off sensor Rearload 5 Attachment point of tear-off sensor Frontload

6 Cable lead-ins into the installation frame 7 Area for cables 8 Cable feed openings underneath the installation frame 9 This side must always point towards the customer panel 10 Wall

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

259 (10.2")
129

max. 360 (14.17")

Installation with frame for partial integration without light box Installation

Drill the required four holes and the hole for the tear-off sensor, if necessary (see following figure).

Installation on raised or cavity flooring as well as on a floating floor is not permissible according to the CEN standard. If the mounting structure differs from the one described below (see illustration below), it must be approved by the insurer. To ensure that the safe does not become detached, the threaded rods of the installation frame must be fastened in the concrete foundation. The drilled holes in the concrete foundation must have a depth of at least 125 mm (4.92") for the installation frame (see illustration below). For the hole diameter please refer to the mounting instructions of the caulking cartridge. The drilled hole in the concrete foundation must have a depth of at least 40 mm (1.57") for the tear-off sensor (see illustration below). Consult your alarm technician about the size of the hole and the fixing.

130

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Installation with frame for partial integration without light box Mounting structure

min. 40 (1.57")

1 2 3 4

Safe Mounting set for safe Tear-off sensor Installation frame

5 6 7 8

Screed Concrete Mounting set for installation frame Top surface of finished floor

* This measure is required if the threaded rods included in the delivery


package are used unmodified. For a different measure the threaded rods must be modified or replaced by equivalent ones.

Clean the drill holes as specified in the mounting instructions of the caulking cartridge. Secure the threaded rods in the concrete foundation as specified in the mounting instructions of the caulking cartridge.

The threaded rods must protrude at a minimum 24 mm (0.94") and at a maximum 25 mm (0.98").

Insert the fixing for the tear-off sensor if required.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

min. 125 (4.92") 176* (6.93"*)


131

25 (0.98")

UL CEN

Installation with frame for partial integration without light box Installation

Remove the filling piece 6b (rearload) or 6a (frontload) and possibly the filling piece 6a (rearload) or 6b (frontload) from the cable lead-ins in the upper part of the installation rack (see positions 6a and 6b in the following illustration (example shows rearload version)).

The space inside the installation frame allows cable lead-in through cable ducts in the floor. If the connecting cables on the site are not located on the safe door side: Insert the data lines, the connecting cable of the remote status indicator (optional) and the power cord through the cable lead-ins and if necessary through the cable feed openings behind the safe door side (11) of the installation frame, as in the example shown here. Make sure that the connecting cables are laid loosely and are not crushed by the installation frame.

11

6b

6a

Screw the installation frame to the floor (for material see section "Mounting sets"). If applicable, note the hardening times of the mounting material.

The threaded rods must not protrude beyond the installation frame. If necessary, level the threaded rods.

132

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Installation with frame for partial integration without light box

Mounting the device on the installation frame


i
Before the frame can be mounted, certain steps are required for systems which have not been prepared for frame installation in the factory (please refer to the mounting instructions supplied with the frame). Remove the blind plugs in positions (1) and (2) on both sides of the device by levering them up from the side (3) and pulling them out forwards (4).

Push the device on the installation frame. Ensure that no cables are damaged in the process. Open the safe door (see chapter "Basic Operation" in the operating manual). If it is necessary for the installation remove those parts inside the unit which secure its components during transportation (see enclosed information sheet). Pull out the CMD-V4 (see chapter "Basic Operation" in the operating manual).

To facilitate access to the attachment points of the safe you can swing the cash media dispenser (CMD-V4) up.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

133

Installation with frame for partial integration without light box Installation

Lifting the cash media dispenser (CMD-V4) up


Put the two track stops (1) (to be found in the safe) in place as shown in the illustration. Remove the reject/retract cassette and the cash-out cassettes (3) (see chapter "Cash Media Dispenser (CMD-V4)" in the operating manual). To reduce the weight, remove all cassettes. Remove the securing screw (2) at the end of the pull-out track, one each on the right and on the left side.

When lifting the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around! Swing the CMD-V4 (1) up until the hole (2) above the pull-out tracks is visible. Push the locking axle (3) (to be found in the safe) in until the grooves are in line with the side panels of the CMD-V4 rack. Check the firm fit of the CMD-V4 by moving it slightly back and forth. When mounting the locking axle ensure that no cables are damaged in the process. Check the CMD-V4 for a secure fit. The locking axle must be firmly in place.

134

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Installation with frame for partial integration without light box

Screwing the device on the installation frame


Place the device on the installation frame and align it (for attachment points (1) and (2) please refer to the illustration) and fasten the safe to the installation frame with screws (for material see section "Mounting sets"). First tighten the rear screws (2) and then the front screws (1) in the safe.

Pushing the cash media dispenser (CMD-V4) down


Lift the CMD-V4 slightly (1) until you may remove the locking axle from the hole (2) in the direction of the arrow (3). Carefully lower the CMD-V4.

When lowering the CMD-V4 make sure that the connecting cables on the rear side of the CMD-V4 controller are not damaged and that they are not moved around!

Mount both securing screws. Remove the two track locks and push the CMD-V4 back into the device. Replace the cassettes.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

135

Installation with frame for partial integration without light box Installation

Installing the power and data cables in the device


Remove the filling piece of the safe.

Feed the data cables and the power cable into the safe, if applicable by the area for cables of the installation frame. If necessary, replace the filling piece of the installation frame (position 6b (rearload) or position 6a (frontload)) and the filling piece of the safe.

136

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Installation with frame for partial integration without light box

Further procedure for CEN installation

Attach the VDS label for the installation frame inside the safe door below the existing VDS label. (The VDS label for the mounted installation frame is included with the installation frame.) After mounting the installation frame and the device, fill out the Confirmation of Installation. (The Confirmation of Installation is included with the installation frame.) Fax the filled out and signed Confirmation of Installation form to the fax number provided on the form.

If there is no fax machine available, the form has to be faxed to this number at a later point in time.

Give the Confirmation of Installation to the operator of the device.

The operator needs the Confirmation of Installation for submitting it to the insurance company.

General
Close the device.

Unpack the parts of the installation frame and install them (see section below "Installing the frame for partial integration without light").

The locking axle and the track stops must remain in the safe for later service operations.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

137

Installation with frame for partial integration without light box Installation

Installing the frame for partial integration without light


View of the frame (completely assembled)
3 4

1 2

1 Right part of frame 2 Left part of frame

3 Top part of frame 4 Frame brackets

138

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Installation with frame for partial integration without light box

Pre-assembling the frame

Attach the top part of the frame and the sides of the frame (items 1, 2 and 3 in the illustration "View of the frame (completely assembled)") on the left and on the right side according to the illustration below using the Taptite round head screws M4x6 (1) and the ratchet washers M5 and the Taptite fillister head screws M5x10 (2).

2x

6x

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

139

Installation with frame for partial integration without light box Installation

Attach the upper mounting brackets (item 4 in the illustration "View of frame (completely assembled)") with two Taptite round head screws M4x6 (3).

4x

140

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Installation with frame for partial integration without light box

Attach the center and lower mounting brackets (item 4 in the illustration "View of frame (completely assembled)") with two Taptite round head screws M4x6 (3) each.

8x

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

141

Installation with frame for partial integration without light box Installation

Mounting the frame

Open the door of the operating unit, release the customer panel and pull it out to the front (please refer to the chapter "Basic Operation", in the operating manual of the ProCash 2000xe / 2000xe USB).

Push the frame from the front in the direction of the arrow (1) up to the customer panel. Lift the frame a little and slide it carefully over the customer panel and let go.

Be careful not to scratch the customer panel.

Push the frame against the wall.

142

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installation Installation with frame for partial integration without light box

2x

4x

Attach the frame brackets on the sides (1) to the device using one pan head screw with inner hexagon M6x10 and a washer 6.4x1.6 and the upper mounting brackets (2) using one Taptite round head screw M4x6 and one washer 4.3 each.

If space is restricted use an appropriate tool that is short enough. When tightening the screws of the frame brackets, make sure that the frame is touching the wall. However, if the wall is uneven, you must not use force to press it in, since the frame could distort when you secure the frame tabs. This could cause the customer panel to grate or jam against the inside of the frame when you open it.

Push the customer panel back in until it engages. Close the door of the operating unit.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

143

Start-up

Installation

Start-up
The service technician will connect the power and data cables.

No power or data cables may be installed below the CMD-V4.

144

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installing the Remote Status Indicator


Remote status indicator - standard
Delivery package

2 3

Pos. Item 1 Remote Status Indicator - Standard (01750047663) with 50 m (164.1 ft) connecting cable (dimensions: 101.2 x 45.7 x 27 mm (3.98" x 1.8" x 1.06") (W x H x D)) Phillips screws SPAX 2.5 x 20 (countersunk head) Fixings 4 mm (0.16")

Quantity required 1

2 3

2 2

The enclosed mounting material is used to secure the indicator to masonry or wooden paneling.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

145

Remote status indicator - standard

Installing the Remote Status Indicator

Installation
1 3 2
Remove the standard remote status indicator from the packaging. Use a screwdriver to press carefully through openings (1) and (2) until the tabs behind them disengage. Remove the front cover (3) forwards.

When drilling the mounting holes, take note of the constructional situation (energy, media line, etc.). Position the lower section and mark the points where it is to be secured.

In masonry only: Drill the necessary bores: drill depth: 20 mm (0.79"), drill diameter: 4 mm (0.16"), and insert the enclosed fixings in the holes. Secure the lower section to the wall with the enclosed screws and press the front cover onto the lower section.

146

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installing the Remote Status Indicator

Remote status indicator - standard An adhesive label with the number 1 is applied in the factory.

Remove the required label (1) and apply it to the space provided (2) on the standard remote status indicator.

Lay the connecting cable of the standard remote status indicator to the appropriate device.

Connection to the relay panel for external features


Open the device (see the device's operating manual). Route the connecting cable through the cable feed openings or the lead-ins into the device (see the section for the appropriate installation version in the chapter "Installation"). Lay the connecting cable in the device to the relay panel for external features so that it cannot be damaged when components are pulled out. Shorten the connecting cable if so required to the appropriate length (see section "Shortening the cable ends").

Marking on wires

The wires are marked with an adhesive label at the end as follows: - 11 RED LIGHT - 12 YELLOW LIGHT - 13 GREEN LIGHT - 14 GND

RED WHITE GREEN BLACK

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

147

Remote status indicator - standard

Installing the Remote Status Indicator

Depending on the device configuration the relay panel for external features can be either equipped with a USB or a DSUB plug. The wire connection is the same for both plugs.

Connect the individual wires to the relay panel for external features as follows:

11 12 13 14 2
1 Relay panel for external features with USB plug 2 Relay panel for external features with DSUB plug Pin 11 12 13 14 Name Wire 'RED - 11 RED LIGHT' Wire 'WHITE - 12 YELLOW LIGHT' Wire 'GREEN - 13 GREEN LIGHT' Wire 'BLACK - 14 GND'

Close the device.

148

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installing the Remote Status Indicator

Remote status indicator - audio

Remote status indicator - audio


Delivery package

2 3
Pos. Item 1 Remote Status Indicator - Audio (01750069332) with 50 m (164.1 ft) connecting cable (dimensions: 118 x 96.5 x 40.5 mm (4.65" x 3.8" x 1.59") (W x H x D)) Phillips screws SPAX 4 x 40 (half-round screws) Fixings 6 mm (0.24") Quantity required 1

2 3

2 2

The enclosed mounting material is used to secure the indicator to masonry or wooden paneling.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

149

Remote status indicator - audio

Installing the Remote Status Indicator

Installation
Remove the audio remote status indicator from the packaging. Loosen screw (1). Move the back panel (2) to one side at the bottom and pull the panel downwards out of the front cover.

When drilling the mounting holes, take note of the constructional situation (energy, media line, etc.). Position the back panel and mark the points where it is to be secured.

Allow sufficient space to install the connecting cable on the right (approx. 20 mm (0.79")).

150

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installing the Remote Status Indicator

Remote status indicator - audio

In masonry only: Drill the necessary bores: drill depth: 40 mm (1.57"), drill diameter: 6 mm (0.24"), and insert the enclosed fixings in the holes. Secure the lower part to the wall with the screws supplied and mount the front cover on the back panel as described above under removal.

An adhesive label with the number 1 is applied in the factory.

Remove the required label (1) and apply it to the space provided (2) on the audio remote status indicator.

Lay the connecting cable of the audio Remote Status Indicator to the appropriate device.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

151

Remote status indicator - audio

Installing the Remote Status Indicator

Connection to the relay panel for external features


Open the device (see the device's operating manual). Route the connecting cable through the cable feed openings or the lead-ins into the device (see the section for the appropriate installation version in the chapter "Installation"). Lay the connecting cable in the device so that it cannot be damaged when components are pulled out. Shorten the connecting cable if so required to the appropriate length (see section "Shortening the cable ends").

Marking on wires

The wires are marked with an adhesive label at the end as follows:

RED WHITE GREEN BLACK

- 11 RED LIGHT - 12 YELLOW LIGHT - 13 GREEN LIGHT - 14 GND

152

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installing the Remote Status Indicator

Remote status indicator - audio

Depending on the device configuration the relay panel for external features can be either equipped with a USB or a DSUB plug. The wire connection is the same for both plugs.

Connect the individual wires to the relay panel for external features as follows:

11 12 13 14 2
1 Relay panel for external features with USB plug 2 Relay panel for external features with DSUB plug Pin 11 12 13 14 Name Wire 'RED - 11 RED LIGHT' Wire 'WHITE - 12 YELLOW LIGHT' Wire 'GREEN - 13 GREEN LIGHT' Wire 'BLACK - 14 GND'

Close the device.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

153

Shortening the cables

Installing the Remote Status Indicator

Shortening the cables


Adapting the cable length at the relay panel end
Shorten the cable end as shown in the following diagram.
60 (23.62") 7 (0.28")

You must strip 60 mm (2.36") of the cable insulation and 7 mm (0.28") of the individual wire insulation. The individual wire ends must be twisted.

Connect the cable as described in the section "Installation".

Adapting the cable length at the standard remote status indicator end
1 3 2
Use a screwdriver to press carefully through openings (1) and (2) until the tabs behind them disengage. Remove the front cover (3) forwards.

Release the four terminals of the terminal strip (1) and remove the front cover.

154

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installing the Remote Status Indicator

Shortening the cables Remove screws (1) and (3) and the strain relief (2). Remove the connecting cable.

Shorten the connecting cable to the desired length. Shorten the cable end as shown in the following diagram.
4.5 (0.18") 60 (23.62")

You must strip 60 mm (2.36") of the cable insulation and 4.5 mm (0.18") of the individual wire insulation. The individual wire ends must be twisted.

Lead the connecting cable through the opening in the lower section and secure it with the strain relief.

Marking on wires

The wires are marked with an adhesive label at the end as follows:

RED WHITE GREEN BLACK

- RED LIGHT - YELLOW LIGHT - GREEN LIGHT - GND

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

155

Shortening the cables

Installing the Remote Status Indicator

Connect the individual wires as follows:

Pin 1 2 3 4

Name Wire 'RED - RED LIGHT' Wire 'WHITE - YELLOW LIGHT' Wire 'GREEN - GREEN LIGHT' Wire 'BLACK - GND'

Press the front cover onto the lower section. Ensure that no wires are damaged in the process.

156

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installing the Remote Status Indicator

Shortening the cables

Adapting the cable length at the remote status indicator (audio)


Loosen screw (1). Move the back panel (2) to one side at the bottom and pull the panel downwards out of the front cover.

Remove the two screws (1) and move the board (2) to one side.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

157

Shortening the cables

Installing the Remote Status Indicator Release the four terminals of the terminal strip and disconnect the cable from the terminal strip (1). Remove the connecting cable with the spacer from cable guide (2).

Remove the spacer from the connecting cable (see arrow). Shorten the connecting cable to the desired length. Push the spacer back on the cable.

Shorten the cable end as shown in the following diagram.

25 (0.98") 4.5 (0.18")

You must strip approx. 25 mm (0.98") of the cable insulation and 4.5 mm (0.18") of the individual wire insulation. The individual wire ends must be twisted.

158

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Installing the Remote Status Indicator Marking on wires

Shortening the cables

The wires are marked with an adhesive label at the end as follows: - RED LIGHT - YELLOW LIGHT - GREEN LIGHT - GND

RED WHITE GREEN BLACK

Connect the individual wires as follows (1):

Pin 1 2 3 4

Name Wire 'RED - RED LIGHT' Wire 'WHITE - YELLOW LIGHT' Wire 'GREEN - GREEN LIGHT' Wire 'BLACK - GND'

Press the connecting cable with the spacer into the cable guide (2). Mount the board and the back panel as described above under removal.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

159

Shortening the cables

Installing the Remote Status Indicator

160

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Appendix
Check list for installation preparations for self-service systems
KS number * Device type Customer address Name Street Town Telephone Contact * Order number Delivery address/location

Customer number or system's serial number

This check list has been created for all self-service systems. Most questions can be answered yes or no. Some empty space is provided in the section "Notes concerning installation preparation" for your convenience if you want to note any questions or drafts. After checking off all items, copy this list, send it to your head of operations and make arrangements for an installation date. Name: Telephone number: Fax number:

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

161

Check list for installation preparations for self-service systems Appendix

General information
Installation in front of a wall through a wall freestanding yes Is the load carrying capacity of the floor sufficient according to the installation documentation? Is there floor heating in the installation area? Are there cavities in the installation area (cable duct, raised floor)? Is the operation and maintenance space sufficient? Is the equipment screened from external light (sunlight)? Is a video surveillance system to be installed? Is a door opener system to be installed? no encased

OK

Preparations
Construction work
yes Is the securing of cash-dispensers in the raw concrete ensured (CEN standard)? Is the frame aligned and fastened in accordance with the installation instructions? Has a wall cutout that may be required been completed? Are the ambient conditions met? no OK

162

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Appendix Check list for installation preparations for self-service systems

Power and data cables


yes Are the AC power outlets available in accordance with the installation instructions? Are the data cables available? Is the alarm connection prepared? Have the camera connection and the door opener been provided? no OK

Organizational preparations
yes Is the generation prepared on the host? Has the MM module or CIM86 been ordered and is it available? Have the encryption/decryption or EPP keys been prepared? Is the paper and money ready for start-up? Have you discussed the diameter of the hole that is to be drilled and the fixing to be used for the tear-off sensor with the local alarm provider? Diameter? Fixing to be used? no OK

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

163

Check list for installation preparations for self-service systems Appendix

Delivery and installation


yes Can a truck drive up to the installation location? Are there steps or obstacles in front of the building? If so, how many? no OK

Are there steps or obstacles inside the building? If so, how many?

Are there mats or grates at the entrance?

Flooring materials on the path of transport


(please check off) Screed/concrete Marble floor Carpet Tiles Raised floor Others

Please enter the width of the most narrow door

Please enter the width of the most narrow hallway

Checked by customer:

Checked by installation technician:

164

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Appendix Check list for installation preparations for self-service systems

Notes concerning installation preparation

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

165

Check list for installation preparations for self-service systems Appendix

166

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Appendix

Technical data

Technical data
General installation conditions
Electrical characteristics of the supply network
Line voltage range: Rated frequency: Network type: Permissible tolerance for voltage range: Permissible tolerance for rated frequency: 110 - 120 V 50/60 Hz TN (network with PE conductor) - 10 % to + 6 % 1% 220 - 240 V 50/60 Hz TN (network with PE conductor) - 10 % to + 6 % 1%

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

167

Technical data

Appendix

Device conditions
110 - 120 V 220 - 240 V Idle Operation Idle Operation mode (maximum) mode (maximum) Device without UPS Rated current consumption: Apparent power consumption: Active power: Power factor: Leakage current (max.): Device with UPS Rated current consumption: Apparent power consumption: Active power: Leakage current (max.):

1.7 A 175 VA 165 W 0.96 1.2 mA

3.2 A 340 VA 295 W 0.91 1.2 mA

0.9 A 190 VA 160 W 0.84 1.2 mA

1.7 A 320 VA 285 W 0.84 1.2 mA

2.7 A 290 VA 265 W 3.5 mA

4.2 A 455 VA 395 W 3.5 mA

1.3 A 280 VA 245 W 3.5 mA

2.1 A 410 VA 370 W 3.5 mA

Protection class: Type of system connection (wall outlet)*:

Fuse protection: Degree of protection in acc. with EN 60529:

Country-specific safety plug CEE plug in acc. with IEC 309 10 A slow-blow fuse or 16 A circuit-breaker IP 20

Country-specific safety plug CEE plug in acc. with IEC 309 10 A slow-blow fuse or 16 A circuit-breaker IP 20

* If a UPS is used, it must be connected with a CEE plug only.

168

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Appendix

Technical data

Installation specifications
ProCash 2000xe / 2000xe USB Frontload with 4-cassette dispenser Dimensions: Height: Width: Depth: 1472 (57.95 600 (23.62 900 (35.43 mm ) mm ) mm ) ProCash 2000xe / 2000xe USB Rearload with 4-cassette dispenser 1472 (57.95 600 (23.62 900 (35.43 mm ) mm ) mm ) ProCash 2000xe / 2000xe USB Rearload with 5-cassette dispenser 1612 (63.46 600 (23.62 900 (35.43 mm ) mm ) mm )

Operation and maintenance space: Device weight: UL safe: CEN L safe: CEN III safe: CEN IV safe:

1.5 m (16.14 ft)

2.3 m (24.75 ft)

2.3 m (24.75 ft)

592 (1305.12 580 (1278.67 765 (1686.72 775 (1708.57

kg lb) kg lb) kg lb) kg lb)

592 (1305.12 580 (1278.67 765 (1686.72 775 (1708.57

kg lb) kg lb) kg lb) kg lb)

880 kg (1940.05 lb)

Surface load: UL safe: CEN L safe: CEN III safe: CEN IV safe:

11.7 (1.70 11.6 (1.68 15.1 (2.19 15.3 (2.22

kN/m lbf/in) kN/m lbf/in) kN/m lbf/in) kN/m lbf/in)

11.7 (1.70 11.6 (1.68 15.1 (2.19 15.3 (2.22

kN/m lbf/in) kN/m lbf/in) kN/m lbf/in) kN/m lbf/in)

17.6 kN/m (2.55 lbf/in)

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

169

Technical data ProCash 2000xe / 2000xe USB Frontload with 4-cassette dispenser Fan capacity: 60 m/h (2118.6 ft/h) ProCash 2000xe / 2000xe USB Rearload with 4-cassette dispenser 60 m/h (2118.6 ft/h)

Appendix ProCash 2000xe / 2000xe USB Rearload with 5-cassette dispenser 60 m/h (2118.6 ft/h)

Detailed information concerning the dimensions is provided in the chapter "Planning the Installation", section "Device dimensions".

170

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Appendix

Technical data

Environmental conditions
Climatic environmental conditions in acc. with EN 60721 Class Operation:* (indoors) Limit range of operation: (indoors)** Transport: Storage: * Ambient temperature C 3K2 + 5 to + 35 * F (+ 41 to + 95) Relative humidity % r.h. 5 to 85

3K3 2K2 1K2

+ 5 to + 40 - 25 to + 60 + 5 to + 40

(+ 41 to + 104) 5 to 85 (- 13 to + 140) 15 to 98 (+ 41 to + 104) 5 to 85

The temperature value of + 35 C (+ 95 F) deviates from the value of the standard (+ 40 C (+ 104 F)).

** In the limit range the device may only be operated for a short period of time.

Mechanical environmental conditions in acc. with EN 60721 Class 3M2 2M2 1M3 Remarks Building with minimal external vibration All types of commercial vehicles and trailers as well as rail and air transport Noticeable vibration and bumps caused for example by machines or passing vehicles

Operation Transport (in original packing) Storage (in original packing)

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

171

Technical data Noise emission in accordance with EN 27779 Noise rating according to ISO 9296 Sound power level LWAd Workplace-related sound pressure level LpAm (at adjacent workplace) * typical operating cycle Idle mode 5.5 B 43 dB

Appendix

Operation * 7.0 B 57 dB

When selecting the installation site, noise emission should be taken into account. Fans in operation or the noise produced during a transaction could disturb people in the immediate vicinity of the device and may therefore need to be diminished with soundproofing (e.g. soundproof cabinets, etc.). They must comply with the environmental conditions that apply to the specific device (see above) and the maintenance areas (see chapter "Planning the Installation", section "Space required for operation and maintenance").

172

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Appendix

Technical data

Compliance with standards and certifications


Standards met
Safety standards: IEC 60950 EN 50371 EN 60950 CSA C22.2-60950 UL 60950

EMC standards: EN 55022 / B EN 55024 ICES-003 (CSA 108.8) FCC CFR 47, part 15, subpart B, class A

Conformity
The CE mark of conformity attached to the product or its package indicates that the product complies with the requirements of the following EC directives: EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC The corresponding statement of compliance has been issued by WINCOR NIXDORF International GmbH Heinz-Nixdorf-Ring 1 33106 Paderborn Germany

Notes concerning radio interference suppression and electrical safety


All other device connected to this product must comply with the EMC Directive 89/336/EEC including the amending directive 93/68/EEC (as of July 20, 2009 EMC Directive 2004/108/EC) and the Low Voltage Directive 73/23/EEC including the amending directive 93/68/EEC (as of January 16, 2007 Low Voltage Directive 2006/95/EC).

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

173

Technical data

Appendix

FCC Rules and Canadian Standard ICES - 003


NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules and Canadian Standard ICES - 003. These limits are designed to provide reasonable protection against harmful interference when the equipment is operating in a commercial environment. The equipment generates, uses and can radiate high frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

UL 291
In order to meet guideline UL 291, ensure the following during installation: The unit must be connected to a grounded receptacle. For a free-standing installation the security container of the ATM shall be anchored in accordance with this instruction, either using the listed anchoring devices or using similar devices. Each anchoring device shall withstand a 22,000 pound (97,861 N) vertical or horizontal force applied in an attempt to remove the security container from its location. If the free-standing installation is inside a building and the anchoring devices cannot be secured to the building structure, the unit shall be attached to a steel plate at least 4 feet by 8 feet by inch thick (1.22 m by 2.44 m by 12.7 mm thick) or an equivalent structure so as to restrict the removal of the teller machine from the building. The release mechanism of the attachment devices shall only be accessible when the door of the security container is open.

Certification for data transmission


The certification number or CE mark of the data transmission module (if available) is attached to the DT card or to the housing of the system unit.

174

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Appendix

Environmental protection

Environmental protection
Environmentally and recycling-friendly product development
This product has been designed according to our corporate guideline 'Environmentally and recycling-friendly product development'. This means that crucial criteria such as long life, choice of material and its labeling, emissions, packaging, ease of disassembly and recyclability have been taken into account. This saves resources and relieves the strain on the environment.

Saving energy
Please switch on devices that need not be constantly running only when they are actually needed. They should also be turned off when they are not needed for longer periods of time.

Disposing of used consumables


Dispose of printer consumables, batteries and cleaning and maintenance materials according to national regulations (where relevant complying with vendor specifications).

Labels on plastic case parts


Please do not stick any labels on plastic case parts since that would make recycling more difficult.

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

175

Environmental protection

Appendix

Returning, recycling and disposing of used units and consumables


Details regarding the return and recycling of used units and consumables can be obtained from your local branch office or from our Environmental Protection section (Referat Umweltschutz): Tel.: Fax: +49 (0) 52 51 693 67 07 +49 (0) 52 51 693-77 67 07

E-Mail: mailto:referat.umweltschutz@wincor-nixdorf.com

176

ProCash 2000xe / 2000xe USB - Installation Guide

01750058375 G

Notes

01750058375 G

ProCash 2000xe / 2000xe USB - Installation Guide

Published by WINCOR NIXDORF International GmbH D-33094 Paderborn

Order No.:

01750058375 G

GB

Você também pode gostar