Você está na página 1de 6

Job Aid

Cabling GuideMCC1 and SCC1 Media Gateway


Avaya S8700 Media Server with Avaya MCC1 or SCC1 Media Gateway

This cabling guide provides graphical representations on various cable connections for the Avaya MCC1 and SCC1 Media Gateways used in an S8700 Multi-Connect configuration. Different ribbon cables are used and CAT5 Ethernet cables connect differently, depending on whether it is a new installation or a migration. See pages 2 and 3. For specific connectivity information, see pages 4 and 5. Although the graphic shows an IPSI in a second port network in a MCC1 Media Gateway with multiple port networks, each port network does not require an IPSI circuit pack. One IPSI can control the whole media gateway. However, when there are remote port networks, you may need to put IPSIs in more than one port network in a media gateway to reach the minimum number of IPSIs required in an S8700 Multi-Connect configuration. Cable identification is shown in Cables used with the MCC1 and SCC1 Media Gateways. Cables used with the MCC1 and SCC1 Media Gateways Comcode 601795495 601930639 601795495 Description H600-204,G1ICCA,B duplication ribbon cables (MCC1). H600-248, G1ICCA,B duplication ribbon cables (SCC1). H600-204,G1ICCC,D duplication ribbon cables. Connectors available only on a J58890AF-2, L13 expansion control carrier with AC1 L5 backplane (vertical Amphenol connectors). Ribbon cablefrom maintenance board to IPSI in MCC1 A carrier (migration only) or SCC1 A media gateway Ribbon cablefrom maintenance board to IPSI in MCC1 B carrier (migration only) Ribbon cablefrom maintenance board to IPSI in SCC1 B media gateway IPSI Amphenol adapter (new installation only) Green CAT5 Ethernet cables 5-meter (16 feet) 25-meter (82 feet) 50-meter (164 feet) Red CAT5 Ethernet cables (high and critical reliability only) 5-meter (16 feet) 25-meter (82 feet) 50-meter (164 feet)

700168727 700168735 700168834 700071251 700170012 700178056 700178064 700170004 700178072 700178122

Issue 3

May 2003

New Shipments - CSS PNC


MCC Single PN
C

MCC Dual PN
C Maintenance

Legend
IPSI EI

Cable in front

Control carrier = heavily outlined carrier


CAT5 cables

Cable in back

Duplex

SCC
D D

H600-204,G1(2) - ICCC - ICCD

H600-204,G1(2) - ICCC A - ICCD

High

Critical

H600-204,G1(4) - ICCA - ICCB - ICCC - ICCD

H600-204,G1(4) - ICCA A - ICCB - ICCC - ICCD

H600-248,G1 - ICCA - ICCB

qrdscbns LAO 031303

Migrations - CSS PNC


MCC Single PN
C

MCC Dual PN
C Maintenance

Legend
IPSI EI

Cable in front

Control carrier = heavily outlined carrier


CAT5 cables

Cable in back

Duplex

SCC
D D

High

Critical

H600-204,G1(2) - ICCA - ICCB

H600-204,G1(2) - ICCA - ICCB

H600-248,G1 - ICCA - ICCB

qrdscbm LAO 031303

New Shipments

B
CLK

S E R V I C E

SERV INTF

AUX

N E T W O R K

TERM

A
RM ALA J MA MIN RN W K AC EM S

TR ER N O

CLK

TO AU OFF

S E R V I C E N E T W O R K

Connecting to IPSI adapter

Connecting ribbon cable (SCC1-high/critical)

CLK

S E R V I C E N E T W O R K

ALARMS MAJ MIN WRN ACK EMER TR


ON AUTO OFF

CLK

S E R V I C E N E T W O R K

ALARMS MAJ MIN WRN ACK EMER TR


ON AUTO OFF

CLK

S E R V I C E N E T W O R K

Connecting to IPSI faceplate (duplex)


qrdsnwsp LAO 032103

Connecting to IPSI faceplate (high/critical)


4

Migrations

CLK

S E R V I C E

N E T W O R K

B
MS AR AL J MA MIN RN W CK A TR ER EM ON
TO F AU OF

CL

A
S E R V I C E N E T W O R K

B
B
AR AL J MA MIN RN W K AC EM TR ER N O
CLK

MS

TO AU OFF

S E R V I C E N E T W O R K

Connecting ribbon cable (duplex)

Connecting ribbon cable (MCC1-high/critical)

CLK

B
CLK

S E R V I C E N E T W O R K

S E R V I C E N E T W O R K

A
B
MS AR AL J MA MIN RN W K AC TR ER EM ON
TO OFF

ALARMS MAJ MIN WRN ACK EMER TR


ON AUTO
CLK

CLK

OFF

S E R V I C E N E T W O R K

AU

S E R V I C E N E T W O R K

Connecting ribbon cable (SCC1-high/critical)


qrdsmigr LAO 032503

Connecting to IPSI faceplate (high/critical)


5

Job Aid

May 2003

Issue 3