Escolar Documentos
Profissional Documentos
Cultura Documentos
CLIENT
INDEX OF DRAWINGS: BS BS BS BS BS 000 100 101 103 104 BUILDING SYSTEMS INDEX SHADING DIAGRAMS WIND CONTROL AND VENTILATION SITE SCALE WIND CONTROL FLOW TABLE ANALYSIS
MALAMA KAUAI
4900 KUAWA ROAD KILAUEA, HI 96754 808.828.0685
CONSULTANTS
LEAD LISA FINDLEY PETER ANDERSON ASSOCIATE CCA FACULTY
NOTES
SERIES DESCRIPTION
SHEET index
bs 000
JUNE 21 12 NOON
DEC 21 12 NOON
JUNE 21 7PM
JUNE 21 7AM
CONSULTANTS
LEAD LISA FINDLEY PETER ANDERSON
OVERHANG + VERANDA
JUNE 21 7PM
JUNE 21 7AM
NOTES
SERIES DESCRIPTION
Shading diagrams
SECTION BUILDING SYSTEMS
SHADING DIAGRAMS
N.T.S.
bs 100
UNCONDITIONED
CORE
CONDITIONED
5MPH TRADEWINDS
PLEASANT BREEZE, IDEAL FOR CROSS-VENTILATION MAXIMUM OPENINGS FOR LIGHT CROSS-BREEZE
CONSULTANTS
LEAD LISA FINDLEY PETER ANDERSON ASSOCIATE CCA FACULTY
CROSS-BREEZE
NOTES
SERIES DESCRIPTION
UNCONDITIONED
CORE
CONDITIONED
15MPH TRADEWINDS
MODERATE BREEZE WINDOW OPENINGS MINIMIZED TO ALLOW VENTILATION ONLY
SCALE
LIGHT VENTILATION NO OUTSIDE AIR ADMITTED
N.T.S.
airflow diagrams
SECTION BUILDING SYSTEMS
AIRFLOW DIAGRAMS
N.T.S.
bs 101
UNCONDITIONED
CORE
CONDITIONED
CONSULTANTS
LEAD LISA FINDLEY PETER ANDERSON ASSOCIATE CCA FACULTY
NOTES
SERIES DESCRIPTION
UNCONDITIONED
CORE
CONDITIONED
SCALE
N.T.S.
airflow diagrams
SECTION BUILDING SYSTEMS
AIRFLOW DIAGRAMS
N.T.S.
bs 102
CONSULTANTS
LEAD LISA FINDLEY PETER ANDERSON ASSOCIATE CCA FACULTY
NOTES
SERIES DESCRIPTION
SCALE
N.T.S.
NORTH
bs 103
ARCHITECT
ORIGINAL CONDITION: Strong winds flowing along Southern veranda on education building, heavy wind through center of site and outdoor assembly space KONA WIND SITE TEST
ADJUSTED CONDITION: Additional plantings adjacent to education building reduce wind entering site complex; addition of plantings between education and assembly reduce wind penetration into central area
CONSULTANTS
LEAD LISA FINDLEY PETER ANDERSON ASSOCIATE CCA FACULTY
ORIGINAL CONDITION: Heavy impact on restaurant, and adjacent outdoor seating area, undesirable strong flow through center of site TRADEWIND BUILDING PLAN TEST
ADJUSTED CONDITION: Plantings South of site in parking area moderate winds before they reach the buildings; plantings south of outdoor seating area beside restaurant create windprotected area as well as prevent strong winds from passing into central area
NOTES
SERIES DESCRIPTION
CONFIGURATION 1: UNCONDITIONED On a day with mild, pleasant winds, all glazing can be opened and a light breeze allowed to flow through the space. Fins help create negative pressure, capture wind and draw it into the spaces.
CONFIGURATION 2: CONDITIONED/UNCONDITIONED When one space requires mechanical conditioning (the box condition) it can be closed down and wind will bypass it, flowing into the next open space.
SCALE
N.T.S.
bs 104