IBM TotalStorage DS8700 242X Model 941

IBM

CDA Microcode Update Instructions


From levels 75.0.xxx.x

75.15.67.0

75.15.67.0 V10

Page 1

Attention Must Read


NEW
Due to a problem in microcode , customers should not IPL there hosts systems during the Storage Facility Update part of this code load procedure. IPL of an attached host could cause repeated warmstarts and cause a loss of access to other attached hosts. A Fix for this problem will be in a future level of microcode. ID 253721 / 253962 For Z/os hosts running PPRC. During host adapter updates on PPRC secondary Control units, the primary control unit may post the following IEA498I type messages.
IEA498I B000,ONLH4Z,PPRC-PATH ONE OR MORE PPRC PATHS REMOVED UNEXPECTEDLY SSID=B000 (PRI)=0175-FRBK1,CCA=00

These messages are considered normal and the PPRC paths will be recovered. Z/os systems. Concurrent copy sessions will be terminated during concurrent code loads. Customers may want to want to terminate concurrent copy sessions before the code load starts.

Z/Series with Sysplex / CFRM couple data sets and PPRC A condition exists that causes a primary volume in PPRC pair to stay in a long busy state (not respond to the host) after a warmstart on the secondary volume in the PPRC pair. The primary volume will stay in the long busy state until I/O is re-driven to the volume or a state change interrupt occurs on the volume. A time-out of the Sysplex primary couple data set will cause the Sysplex to switch to the alternate coupled data set. If the alternate couple data set volume times out, this will cause sysplex-wide failure. Sysplex customers should not include volumes containing any Sysplex couple data set in an active PPRC pair, with the exception of the LOGR couple data set. For example: A concurrent code load could possibly see a warmstart and cause this problem to occur. Customers who do not follow the above advice to exclude Sysplex/CFRM couple data sets from an active PPRC relation , MUST remove / suspend PPRC pairs of volumes with Sysplex/CFRM couple data sets prior to a concurrent code load. A link to the Sysplex planning guide for IBM recommendations is provided below.
http://publib.boulder.ibm.com/infocenter/zos/v1r9/index.jsp?topic=/com.ibm.zos.r9.ieaf100/allcds.htm

Machines with RPQ 8S0849 or 8S0871 ( deferred DDM disablement ) must re-install this RPQ after this code load. If the CD's you have are not the following part numbers, see Tip 871 in the DS8000 PE field tips WEB page or data base. Instructions for re-installing the RPQ are also in Tip 871. 8S0949 P/N 45W8884 8S0871 P/N 45W8885
During any code load , Retain registration should be verified for all rack serial numbers in this Storage Facility. Sign on to RETAIN to verify that each new and existing rack in this storage facility is registered. Enter n;z/cpu 2NNNPPSSSSS where: 2NNN Machine type of 2107, 2421, 2422, 2423, or 2424 PP Plant of manufacture SSSSS The last 5 digits of the serial number. Valid Maintenance status is 1,2,or 9 If the command output returns UNKNOWN CPU SPECIFIED, ask the support center to register the rack serial number in Retain . Note: Some countries register using 00 instead of the actual two-digit plant of manufacture code.

75.15.67.0 V10

Page 2

Media required for update


BUNDLE DVD The Target bundle is the 75.15.67.0 Bundle DVD that contains the bundle file and the following content. AIX_PTF CD, HMC_ICAT_GUI CD, HMC_MM_EXT CD, Power CD, SEA CD, P6 CD

Leave all media (CDs, DVDs) used for this procedure with the machine for possible future recovery actions. Remove older media from machine and discard.
CDA Bundle Contents BUNDLE VERSION: 75.15.67.0

HMC Levels HMC_MCP_SQ_BASE or HMC Build Level HMC_MM_EXT or DS8000 HMC LMC HMC_ICAT_GUI or ibmdsstoragemanager8000.base HMC_CIM Agent Squadrons (P6) Managed System SFI AIX_PTF SEA (CPSS) Host Adapter Fibre/Ficon Device adapters Power Power code levels PPS Flash RPC Flash Storage Enclosures FCIC (Fiber Chan. Int card) Customer DSCLI Client

Version: MM_ECL350_1005F_0128.1 Version: 25.53.0-20101110.1 Version: 5.5.15.1084 Version: 5.5.15.54-1 Version: 01FM340_115_039 Version: 6.1.2.504 Version: 6.5.15.90 (R14i.6b101129a) Level: 03202011095950 Level: 201015200007 Version: VER00078 Version: 2716 Version: 27 Version: 19-01 Version: 6.5.15.90

Code loads are only supported from the levels that are listed in the chart below.
Bundle 75.15.67.0 75.15.60.0 75.15.59.0 75.0.184.0 75.0.177.0 75.0.158.0 75.0.149.0 HMC 45 min HMC ^ ^ MM_ECL350_1005F_0128.1 ^ MM_ECL342_0938A_0929.1 MM_ECL342_0935A_0911.1 MM_ECL342_0935A_0824.1 MM_EXT ^ ^ 20101110.1 ^ 20091031.1 20090925.1 20090903.1 60 min P6 ^ ^ 01FM340_115 ^ 01SF340_088 ^ 01SF340_087 30 min AIX PTF ^ ^ 6.1.2.504 ^ ^ ^ 6.1.2.402 60 min SEA 6.5.15.90 6.5.15.79 6.5.15.78 6.5.0.251 6.5.0.246 6.5.0.220 6.5.0.215 100 min PPS/RPC ^ ^ 2716/V27 ^ ^ ^ 2716/V17 30-60 SES ^ ^ ^ ^ ^ ^ 19_01

75.15.67.0 V10

Page 3

Section 1

Acquire Release Bundle and Distribute

Warning: If this machine is currently at 75.1.XX.X code , you are in the wrong instructions. Please return to web site at use the CDApreload instructions. Select: Updates Select: Check radio button on the HMC line Select: Acquire Code Images a) If you are using physical media to acquire code, continue with this step, if using the network, go to step b or c. Removable Media (CDROM) radio button is selected Select go Insert the Target Release Bundle DVD as called for by screens A pop-up will indicate the acquisition is complete

--->>>> Remove media and continue to the next section


b) Network Acquire - Using FTP -- Select Network radio button Add Server address: ftp.software.ibm.com/storage/ds8000 Select: Check Anonymous box then Go Highlight the code bundle to acquire Select: Ok A series of Progress Dialog screens will indicate the files are being read. A pop-up will indicate the acquisition is complete, c) Network Acquire using TLS(FTPS) -- Select Network radio button Select: Check Secure HTTP (SSL) box Add Server address: testcase.boulder.ibm.com/ds8000 Enter: Username and Password From tip 490 and then Go Highlight the code bundle to acquire Select: Ok A series of Progress Dialog screens will indicate the files are being read. A pop-up will indicate the acquisition is complete

Section 2 HMC Update Update the HMC to the Latest Bundle


The next steps will activate the HMC code for the target Bundle 75.15.59.0 Select: Updates Select: The check box on the HMC line. Select: Update HMC Code from the tasks screen. Highlight the desired code level 75.15.59.0 Select: Ok At Proceeding with the update will take the HMC offline. Select: Yes A series of screens will indicate which component is being updated. At "An HMC reboot is necessary. Press OK to reboot?" Select: OK HMC will reboot. Once the HMC has rebooted the HMC update is complete **If the HMC hangs at initialize screen for more that 5 minutes , reboot again by selecting the Alt Ctrl and F1 keys , then Alt Ctrl Del keys. Use Alt and Ctrl keys on the left side of keyboard. For Dual HMC configurations, Return to section 1 and acquire and update HMC2

75.15.67.0 V10

Page 4

Run cdaPreverify
Select: Updates Select: The check box on the Storage Facility line. Select: Run CdaPreVerify from the tasks screen. Select: Ok to display the results screen. If full system scan fails, read the log file displayed and correct the problem before proceeding. Select Ok to close the results screen.

Section 3

Update Storage Facility Image - CCL

Storage Facility Code Update Select: Updates Select: The check box on the Storage Facility line. Select: Update Storage Facility Code Highlight: The Storage Facility Image to be updated Select: OK The Select a Code Level menu will be displayed Highlight the desired code level. 75.15.59.0 Select: Distribute and Activate CCL This will initiate the update (A task progress window will display within 3 minutes.) Task is in progress - Do not close this window This panel will display the operations involved in the CCL update. When the window indicates that the update is complete Click: Ok For Multiple Storage Facilities on HMC #1 , Section 7 - Update Storage Facility Image - CCL on the remaining Storage Facilities.

75.15.67.0 V10

Page 5

Section 4

Update Power Component Firmware

- CCL

Power System firmware update * Interactive


Visually check the following power LEDS are on and not flashing. --RPC cards --I/O enclosures Power Supply LEDS --Rear power supplies LEDs on CEC's --No error indicators on either PPS *** All power problems must be repaired before continuing *** For Dual HMC machines there should be no open problems on either HMC before continuing. Open problems other than differed DDM's will cause the power update to suspend.

Power firmware update instructions


Select: Updates Select: The check box on the Storage Facility line. Select: Recovery Utilities from the tasks screen. Select: CCL Utilities Select: Okay Select: CCL Power Firmware Update Select: Okay Select an SFI menu displays, Highlight: (2107-9xx - - -) Select: Okay Select a code level menu displays, Highlight the desired code level. Select: Ok This will initiate the update Task is in progress - Do not close this window This panel will display the operations involved in the CCL power update{est.40 Minutes}

75.15.67.0 V10

Page 6

1) After the RPC0 and RPC1 cards and top PPSs have been updated a screen will appear that has you check the power LEDS to insure the power supplies have powered backed on. Visually check the following power LEDS are on and not flashing. --RPC cards --I/O enclosures Power Supply LEDS --Rear power supplies LEDs on CEC's --No error indicators on either PPS If all power LEDS checked are ok select yes and continue the power firmware update. If any power LEDS are found incorrect , answer no and repair the failed power supply. After the repair is completed start the power firmware update from the beginning.

2) If all the LEDS are correct select yes . If power LEDS are incorrect select no and repair the power supply problem. Then return and rerun power update procedure. 3) After selecting yes , the bottom PPSs with update and when complete the LED Check screen will appear. **** Always answer Yes to this screen***** Visually check the following power LEDS are on and not flashing. --RPC cards --I/O enclosures Power Supply LEDS --Rear power supplies LEDs on CEC's --No error indicators on either PPS If all power LEDS checked are ok select yes and continue the power firmware update. If any power LEDS are found incorrect, answer no and repair the failed power supply. After the repair is completed start the power firmware update from the beginning.

4) Again check all the LEDS. Always answer Yes to this screen even if LED problems are found. If incorrect LEDs are found, repair and return to this step. Note: Selecting no at the second screen prompt with leave norsStart files on the LPARs 5) If all Storage Facilities are complete Select Ok For machines with more Storage Facilities attached you will return to Power System firmware updates and update power firmware in those Storage Facilities

75.15.67.0 V10

Page 7

Section 4

Run Final Checks

Step 1) Run end of call Select: Storage Facility Management Select: The check box on the Storage Facility line. Select: Service Utilities Select: View Storage Facility State All sections should report with passed in the status column. Failed status can be viewed by highlighting the System Check Type and then select details. Select: Cancel to close the screen. Step 2) Verify all Code levels are installed Select: Updates Select: The check box on the Storage Facility line. Select: Display Storage Facility Code Levels The action panel will display all code levels now installed. Verify, with CDA Bundle contents page, all code levels have successfully been installed on all Storage Facility Images and all Storage Facilities. Select: Ok to close screen Step 3) Perform backup critical data to the Storage Facility Hard drive( LPAR ) Select: HMC management From Storage Server HMC tasks Select: Backup Critical data (time less than 10 minutes) Click OK. ***Automatic Critical backups will occur at 11:00 PM on Thursdays. Step 4) Verify MRPD settings. Select: Service Management Select: Transmit Service Information Under Transmit Tab, Service Information Transmission
If "schedule when to transmit the service information" is not checked it must be set to on check "schedule when to transmit the service information" box and click OK click OK at successfully updated settings

For Dual HMC configurations,


For dual HMC's , verify MRPD is enabled on HMC 2 also. This level of code supports alt HMC backup MRPD transmissions.

Leave all media (CDs, DVDs) used for this migration procedure with the machine for possible future recovery actions. End of Update

75.15.67.0 V10

Page 8

ECA 814 should be installed after the above code load completes. Description and summary of DDM firmware update
The method of loading and updating the targeted DDM's families firmware is different than procedures used in the past. This update is done with a special CD using the HMC Corrective Service facility and is automated from there. Once the CD is loaded the new DDM firmware is transferred onto the machine and then the firmware update of any listed DDM families begins and updates one DDM at a time across device adapter pairs. Multiple updates will be occurring across the device adapter pairs depending on the machine configuration. Time for the update will be determined by the maximum number of affected DDM's on a device adapter pair. Updates on a device adapter pair are done at a rate of 1 every 2 minutes. So a maximum time with 128 DDM's updating will be be approximately 256 minutes. ( 4 hrs 16 minutes ). This is done concurrently with Customer I/O. If any failures occur on a DDM during the update process , the update will stop on the device adapter pair for that DDM. and continue on the other device adapter pairs if they were also doing updates. Normal repair actions would be performed on the failed DDM, and the update process will need to be started again with this update procedure to finish the remaining DDM's on the device adapter that failed. Updates will only occur on drives that had not updated before the DDM failure. At the end of the update a long process to harvest all the DDM information is begun and DDM code level checking will not be correct until the harvest is complete. It not necessary to confirm the DDM firmware as long as the update did not fail and no SRC's are generated.

Machines affected
DDM Family S5C(D,E or F) S5D(E,F or G) S5E(E,F or G) S5F(F,G or H) S5G(F,G or H)

Model 941 or 94E Machines with DDM families in chart below and firmware levels below the level indicated.

Required Firmware Level 9528 A332 E40C A50A E50C (T) (H) (HFDE) (E) (ESED)

Checking DDM firmware levels only if desired


HMC's with multiple Storage Facilities and/or Multiple Storage Facility Images will need to go through the procedure for all affected DDM's In the HMC complex. Logon to WUI Select: Updates Select: Radio Button on Storage Facility line Select: Recovery Utilities Select: DDM Utilities Select: Display DDM Code levels

75.15.67.0 V10

Page 9

Checking machine and replacing any deferred DDM's


Run cdaPreverify Select: Updates Select: The check box on the Storage Facility line. Select: Run CdaPreVerify from the tasks screen. If full system scan fails, read the log file displayed and correct the problem before proceeding. Select Ok to close the results screen. All problems must be resolved before continuing Deferred DDMs (SRN BE34XXXX ) must be replaced prior to the DDM firmware Update . If any DDM's are replaced , they must complete formatting before starting this update. DDM format completion can be checked from End of Call.

75.15.67.0 V10

Page 10

Moving new DDM Firmware to machine and automatic update with corrective service CD.
Running multiple instances of this program can cause undesirable results. If program must be run a second time , insure that the first progress window has completed before loading the corrective service CD a second time. CD required for HMCv7 updateHTEFirmware_CCL_r_5_4_v1.2

Select: HMC Management (Left Side) Select: Install Corrective Service (Right Side) New Window Opens Confirm Current HMC Driver Information Select: Next Displays Select Service Repository Select: Removable Media Select: Next Insert Corrective Service CD into HMC DVD drive. (updateHTEFirmware_CCL_r_5_4_v1.2) Select: CD-ROM or DVD Select: Next Select: Media Image (No Description) Select: Next Displays Confirm Service Installation Media Type: CD-ROM or DVD Service Package: Media Image Select: Finish Install Corrective Service Action begins The CD will run and display results of the Process DDM fast sparing is checked at this time, if enabled the update will stop and require this option to be disabled. Contact support to use SMART menu's to disable Fast Sparing . Do not reboot the HMC Select: No Select: Updates Select: Radio Button on Storage Facility line Expand: Recovery Utilities Select: DDM Utilities Select: Display DDM Update Status Monitor update status from the displayed progress window until complete, then OK After the update is completed, HMC harvest of DDM information begins and could take several hours depending on total machine size. It is not required or recommended to verify DDM firmware levels as long as the update process completed without failures.

75.15.67.0 V10

Page 11

Run End of call


Select: Storage Facility Management Select: The check box on the Storage Facility line. Select: Service Utilities Select: View Storage Facility State All sections should report with passed in the status column. Failed status can be viewed by highlighting the System Check Type and then select details. Select: Cancel to close the screen. If Fasts Sparing was disabled to allow the DDM firmware updating , contact support to reenable Fast Sparing from the SMART menu's

75.15.67.0 V10

Page 12

Appendix
Description of host adapter settings for update during concurrent code load.
The preferred settings for code load that will be faster with no manual intervention are : FICON fast load enabled (default on ) CDA setting CUIR Set during machine install. Recommended setting ( true ) Interactive host adapter update ( default off ) CDA setting Host adapter settings and support Fiber card Fastload FICON Fast load off CUIR CUIR off Interactive Update yes Still uses fastload N/A N/A Yes

Fiber card (FICON) yes Will use CUIR if enabled Yes if FICON fastload is off If FICON fastload is off ,SRN created for manual dummy rep Yes

Mixing topology's on fiber cards and turning FICON fast load off will result in the card being skipped and an SRN generated for manual dummy replacement of the card. Instructions for checking / changing CUIR options. Select: Storage Facility Management Select: The Storage Facility Select: The storage Facility Image # Select: Service Utilities Select: Enable/Disable control Switches Observe the setting for CUIR , if needed change the setting and select set Select: Cancel to close the screen. Instructions for disabling FICON Fastload, when required. Select: Updates Select: The check box on the Storage Facility line. Select: Recovery Utilities Select: Advanced Configuration Select the configuration option from the list Highlight "FICON Fastload Disable" and press Save Selected Configuration Confirm Selection and select Continue The CDA Concurrent Code Load process will prompt that the default configuration is not set and ask that you confirm the settings. Validate that only the Desired options are set at that time and select continue or cancel as appropriate. After completing the Concurrent Code Update, restore the default configuration of advanced options. ( Note: to select 2 options at once the use the CTRL key )

75.15.67.0 V10

Page 13

Instructions for enabling interactive Host adapter update, when required. Select: Updates Select: The check box on the Storage Facility line. Select: Recovery Utilities Select: Advanced Configuration Select the configuration option from the list Highlight "Interactive HA" and press Save Selected Configuration Confirm Selection and select Continue The CDA Concurrent Code Load process will prompt that the default configuration is not set and ask that you confirm the settings. Validate that only the Desired options are set at that time and select continue or cancel as appropriate. After completing the Concurrent Code Update, restore the default configuration of advanced options.

75.15.67.0 V10

Page 14