These messages are considered normal and the PPRC paths will be recovered. Z/os systems. Concurrent copy sessions will be terminated during concurrent code loads. Customers may want to want to terminate concurrent copy sessions before the code load starts.
Z/Series with Sysplex / CFRM couple data sets and PPRC A condition exists that causes a primary volume in PPRC pair to stay in a long busy state (not respond to the host) after a warmstart on the secondary volume in the PPRC pair. The primary volume will stay in the long busy state until I/O is re-driven to the volume or a state change interrupt occurs on the volume. A time-out of the Sysplex primary couple data set will cause the Sysplex to switch to the alternate coupled data set. If the alternate couple data set volume times out, this will cause sysplex-wide failure. Sysplex customers should not include volumes containing any Sysplex couple data set in an active PPRC pair, with the exception of the LOGR couple data set. For example: A concurrent code load could possibly see a warmstart and cause this problem to occur. Customers who do not follow the above advice to exclude Sysplex/CFRM couple data sets from an active PPRC relation , MUST remove / suspend PPRC pairs of volumes with Sysplex/CFRM couple data sets prior to a concurrent code load. A link to the Sysplex planning guide for IBM recommendations is provided below.
http://publib.boulder.ibm.com/infocenter/zos/v1r9/index.jsp?topic=/com.ibm.zos.r9.ieaf100/allcds.htm
Machines with RPQ 8S0849 or 8S0871 ( deferred DDM disablement ) must re-install this RPQ after this code load. If the CD's you have are not the following part numbers, see Tip 871 in the DS8000 PE field tips WEB page or data base. Instructions for re-installing the RPQ are also in Tip 871. 8S0949 P/N 45W8884 8S0871 P/N 45W8885
During any code load , Retain registration should be verified for all rack serial numbers in this Storage Facility. Sign on to RETAIN to verify that each new and existing rack in this storage facility is registered. Enter n;z/cpu 2NNNPPSSSSS where: 2NNN Machine type of 2107, 2421, 2422, 2423, or 2424 PP Plant of manufacture SSSSS The last 5 digits of the serial number. Valid Maintenance status is 1,2,or 9 If the command output returns UNKNOWN CPU SPECIFIED, ask the support center to register the rack serial number in Retain . Note: Some countries register using 00 instead of the actual two-digit plant of manufacture code.
75.15.67.0 V10
Page 2
Leave all media (CDs, DVDs) used for this procedure with the machine for possible future recovery actions. Remove older media from machine and discard.
CDA Bundle Contents BUNDLE VERSION: 75.15.67.0
HMC Levels HMC_MCP_SQ_BASE or HMC Build Level HMC_MM_EXT or DS8000 HMC LMC HMC_ICAT_GUI or ibmdsstoragemanager8000.base HMC_CIM Agent Squadrons (P6) Managed System SFI AIX_PTF SEA (CPSS) Host Adapter Fibre/Ficon Device adapters Power Power code levels PPS Flash RPC Flash Storage Enclosures FCIC (Fiber Chan. Int card) Customer DSCLI Client
Version: MM_ECL350_1005F_0128.1 Version: 25.53.0-20101110.1 Version: 5.5.15.1084 Version: 5.5.15.54-1 Version: 01FM340_115_039 Version: 6.1.2.504 Version: 6.5.15.90 (R14i.6b101129a) Level: 03202011095950 Level: 201015200007 Version: VER00078 Version: 2716 Version: 27 Version: 19-01 Version: 6.5.15.90
Code loads are only supported from the levels that are listed in the chart below.
Bundle 75.15.67.0 75.15.60.0 75.15.59.0 75.0.184.0 75.0.177.0 75.0.158.0 75.0.149.0 HMC 45 min HMC ^ ^ MM_ECL350_1005F_0128.1 ^ MM_ECL342_0938A_0929.1 MM_ECL342_0935A_0911.1 MM_ECL342_0935A_0824.1 MM_EXT ^ ^ 20101110.1 ^ 20091031.1 20090925.1 20090903.1 60 min P6 ^ ^ 01FM340_115 ^ 01SF340_088 ^ 01SF340_087 30 min AIX PTF ^ ^ 6.1.2.504 ^ ^ ^ 6.1.2.402 60 min SEA 6.5.15.90 6.5.15.79 6.5.15.78 6.5.0.251 6.5.0.246 6.5.0.220 6.5.0.215 100 min PPS/RPC ^ ^ 2716/V27 ^ ^ ^ 2716/V17 30-60 SES ^ ^ ^ ^ ^ ^ 19_01
75.15.67.0 V10
Page 3
Section 1
Warning: If this machine is currently at 75.1.XX.X code , you are in the wrong instructions. Please return to web site at use the CDApreload instructions. Select: Updates Select: Check radio button on the HMC line Select: Acquire Code Images a) If you are using physical media to acquire code, continue with this step, if using the network, go to step b or c. Removable Media (CDROM) radio button is selected Select go Insert the Target Release Bundle DVD as called for by screens A pop-up will indicate the acquisition is complete
75.15.67.0 V10
Page 4
Run cdaPreverify
Select: Updates Select: The check box on the Storage Facility line. Select: Run CdaPreVerify from the tasks screen. Select: Ok to display the results screen. If full system scan fails, read the log file displayed and correct the problem before proceeding. Select Ok to close the results screen.
Section 3
Storage Facility Code Update Select: Updates Select: The check box on the Storage Facility line. Select: Update Storage Facility Code Highlight: The Storage Facility Image to be updated Select: OK The Select a Code Level menu will be displayed Highlight the desired code level. 75.15.59.0 Select: Distribute and Activate CCL This will initiate the update (A task progress window will display within 3 minutes.) Task is in progress - Do not close this window This panel will display the operations involved in the CCL update. When the window indicates that the update is complete Click: Ok For Multiple Storage Facilities on HMC #1 , Section 7 - Update Storage Facility Image - CCL on the remaining Storage Facilities.
75.15.67.0 V10
Page 5
Section 4
- CCL
75.15.67.0 V10
Page 6
1) After the RPC0 and RPC1 cards and top PPSs have been updated a screen will appear that has you check the power LEDS to insure the power supplies have powered backed on. Visually check the following power LEDS are on and not flashing. --RPC cards --I/O enclosures Power Supply LEDS --Rear power supplies LEDs on CEC's --No error indicators on either PPS If all power LEDS checked are ok select yes and continue the power firmware update. If any power LEDS are found incorrect , answer no and repair the failed power supply. After the repair is completed start the power firmware update from the beginning.
2) If all the LEDS are correct select yes . If power LEDS are incorrect select no and repair the power supply problem. Then return and rerun power update procedure. 3) After selecting yes , the bottom PPSs with update and when complete the LED Check screen will appear. **** Always answer Yes to this screen***** Visually check the following power LEDS are on and not flashing. --RPC cards --I/O enclosures Power Supply LEDS --Rear power supplies LEDs on CEC's --No error indicators on either PPS If all power LEDS checked are ok select yes and continue the power firmware update. If any power LEDS are found incorrect, answer no and repair the failed power supply. After the repair is completed start the power firmware update from the beginning.
4) Again check all the LEDS. Always answer Yes to this screen even if LED problems are found. If incorrect LEDs are found, repair and return to this step. Note: Selecting no at the second screen prompt with leave norsStart files on the LPARs 5) If all Storage Facilities are complete Select Ok For machines with more Storage Facilities attached you will return to Power System firmware updates and update power firmware in those Storage Facilities
75.15.67.0 V10
Page 7
Section 4
Step 1) Run end of call Select: Storage Facility Management Select: The check box on the Storage Facility line. Select: Service Utilities Select: View Storage Facility State All sections should report with passed in the status column. Failed status can be viewed by highlighting the System Check Type and then select details. Select: Cancel to close the screen. Step 2) Verify all Code levels are installed Select: Updates Select: The check box on the Storage Facility line. Select: Display Storage Facility Code Levels The action panel will display all code levels now installed. Verify, with CDA Bundle contents page, all code levels have successfully been installed on all Storage Facility Images and all Storage Facilities. Select: Ok to close screen Step 3) Perform backup critical data to the Storage Facility Hard drive( LPAR ) Select: HMC management From Storage Server HMC tasks Select: Backup Critical data (time less than 10 minutes) Click OK. ***Automatic Critical backups will occur at 11:00 PM on Thursdays. Step 4) Verify MRPD settings. Select: Service Management Select: Transmit Service Information Under Transmit Tab, Service Information Transmission
If "schedule when to transmit the service information" is not checked it must be set to on check "schedule when to transmit the service information" box and click OK click OK at successfully updated settings
Leave all media (CDs, DVDs) used for this migration procedure with the machine for possible future recovery actions. End of Update
75.15.67.0 V10
Page 8
ECA 814 should be installed after the above code load completes. Description and summary of DDM firmware update
The method of loading and updating the targeted DDM's families firmware is different than procedures used in the past. This update is done with a special CD using the HMC Corrective Service facility and is automated from there. Once the CD is loaded the new DDM firmware is transferred onto the machine and then the firmware update of any listed DDM families begins and updates one DDM at a time across device adapter pairs. Multiple updates will be occurring across the device adapter pairs depending on the machine configuration. Time for the update will be determined by the maximum number of affected DDM's on a device adapter pair. Updates on a device adapter pair are done at a rate of 1 every 2 minutes. So a maximum time with 128 DDM's updating will be be approximately 256 minutes. ( 4 hrs 16 minutes ). This is done concurrently with Customer I/O. If any failures occur on a DDM during the update process , the update will stop on the device adapter pair for that DDM. and continue on the other device adapter pairs if they were also doing updates. Normal repair actions would be performed on the failed DDM, and the update process will need to be started again with this update procedure to finish the remaining DDM's on the device adapter that failed. Updates will only occur on drives that had not updated before the DDM failure. At the end of the update a long process to harvest all the DDM information is begun and DDM code level checking will not be correct until the harvest is complete. It not necessary to confirm the DDM firmware as long as the update did not fail and no SRC's are generated.
Machines affected
DDM Family S5C(D,E or F) S5D(E,F or G) S5E(E,F or G) S5F(F,G or H) S5G(F,G or H)
Model 941 or 94E Machines with DDM families in chart below and firmware levels below the level indicated.
Required Firmware Level 9528 A332 E40C A50A E50C (T) (H) (HFDE) (E) (ESED)
75.15.67.0 V10
Page 9
75.15.67.0 V10
Page 10
Moving new DDM Firmware to machine and automatic update with corrective service CD.
Running multiple instances of this program can cause undesirable results. If program must be run a second time , insure that the first progress window has completed before loading the corrective service CD a second time. CD required for HMCv7 updateHTEFirmware_CCL_r_5_4_v1.2
Select: HMC Management (Left Side) Select: Install Corrective Service (Right Side) New Window Opens Confirm Current HMC Driver Information Select: Next Displays Select Service Repository Select: Removable Media Select: Next Insert Corrective Service CD into HMC DVD drive. (updateHTEFirmware_CCL_r_5_4_v1.2) Select: CD-ROM or DVD Select: Next Select: Media Image (No Description) Select: Next Displays Confirm Service Installation Media Type: CD-ROM or DVD Service Package: Media Image Select: Finish Install Corrective Service Action begins The CD will run and display results of the Process DDM fast sparing is checked at this time, if enabled the update will stop and require this option to be disabled. Contact support to use SMART menu's to disable Fast Sparing . Do not reboot the HMC Select: No Select: Updates Select: Radio Button on Storage Facility line Expand: Recovery Utilities Select: DDM Utilities Select: Display DDM Update Status Monitor update status from the displayed progress window until complete, then OK After the update is completed, HMC harvest of DDM information begins and could take several hours depending on total machine size. It is not required or recommended to verify DDM firmware levels as long as the update process completed without failures.
75.15.67.0 V10
Page 11
75.15.67.0 V10
Page 12
Appendix
Description of host adapter settings for update during concurrent code load.
The preferred settings for code load that will be faster with no manual intervention are : FICON fast load enabled (default on ) CDA setting CUIR Set during machine install. Recommended setting ( true ) Interactive host adapter update ( default off ) CDA setting Host adapter settings and support Fiber card Fastload FICON Fast load off CUIR CUIR off Interactive Update yes Still uses fastload N/A N/A Yes
Fiber card (FICON) yes Will use CUIR if enabled Yes if FICON fastload is off If FICON fastload is off ,SRN created for manual dummy rep Yes
Mixing topology's on fiber cards and turning FICON fast load off will result in the card being skipped and an SRN generated for manual dummy replacement of the card. Instructions for checking / changing CUIR options. Select: Storage Facility Management Select: The Storage Facility Select: The storage Facility Image # Select: Service Utilities Select: Enable/Disable control Switches Observe the setting for CUIR , if needed change the setting and select set Select: Cancel to close the screen. Instructions for disabling FICON Fastload, when required. Select: Updates Select: The check box on the Storage Facility line. Select: Recovery Utilities Select: Advanced Configuration Select the configuration option from the list Highlight "FICON Fastload Disable" and press Save Selected Configuration Confirm Selection and select Continue The CDA Concurrent Code Load process will prompt that the default configuration is not set and ask that you confirm the settings. Validate that only the Desired options are set at that time and select continue or cancel as appropriate. After completing the Concurrent Code Update, restore the default configuration of advanced options. ( Note: to select 2 options at once the use the CTRL key )
75.15.67.0 V10
Page 13
Instructions for enabling interactive Host adapter update, when required. Select: Updates Select: The check box on the Storage Facility line. Select: Recovery Utilities Select: Advanced Configuration Select the configuration option from the list Highlight "Interactive HA" and press Save Selected Configuration Confirm Selection and select Continue The CDA Concurrent Code Load process will prompt that the default configuration is not set and ask that you confirm the settings. Validate that only the Desired options are set at that time and select continue or cancel as appropriate. After completing the Concurrent Code Update, restore the default configuration of advanced options.