Fresh Air Ventilation and Heat Exchange unit SAF-E4


Model No. SAF250E4 SAF350E4 SAF500E4 SAF800E4 SAF1000E4

Re; Building Regulations Part L2


The Part L2 (April 2006) regulations limit the amount of electrical/gas power to be used to provide heating or cooling in commercial buildings. Therefore the building designer needs to select energy efficient heating/cooling equipment, and to minimise energy losses through ventilation systems. The SAF recovers heat energy which would otherwise be exhausted to atmosphere, and uses this energy to warm the air entering the building. The reverse happens in warmer climates, where the exhausted cool air is used to partially cool the incoming air.
Structure (SAF1000E4)
Plate heat exchanger Damper Exhaust Air

Capturing this waste energy, means the heating/ cooling requirements of the building are reduced, so smaller size plant can be selected, savings can be made in long term energy consumption, and carbon emissions are reduced. The inclusion of the SAF energy recovery ventilation units in the building design, will reduce the total amount of carbon emissions.

Principle of operation (simple ventilation) FREE COOLING


outdoor indoor Supply Air

Principle of operation (heat exchanging) ENERGY RECOVERY


Exhaust Air outdoor indoor Supply Air

EA (Exhaust Air)

RA (Room Air)

27deg Outside Air 10deg

10deg Room Air 27deg e.g. For cooling in winter time

33deg Outside Air 35deg

29deg Room Air 27deg

OA (Outside Air)

SA (Supply Air)

Specifications
Item Model Power source Exterior dimensions mm Height x Width x Depth Exterior appearance Power input W Running current A Enthalpy Cooling exchange UHi efficiency Heating Temperature exchange efficiency Enthalpy Cooling exchange Hi efficiency Heating % Temperature exchange efficiency Enthalpy Cooling exchange Lo efficiency Heating Temperature exchange efficiency Motor & Qty kW Air handling equipment Fan type & Qty UHi Air flow Hi m3/h Lo UHi Available static pressure Hi Pa Lo Remote control Out take intake air Air filter Exhaust air

SAF250E4
270x882x599 99-114 0.46-0.48 63 70 63 70 66 73 77 0.02x2 250 250 170 90 80 37

SAF350E4
170x882x804 124-137 0.59-0.60 66 69 66 69 69 71 77 0.044x2 350 350 280 95 65 42

SAF500E4
1 Phase 220-240V, 50Hz 270x962x904 Galvanised steel sheet 169-188 0.79-0.81 62 67 75 62 67 75 77 67 75 0.062x2 Sirocco fan x 2 500 500 370 105 70 38 Standard equipment Protection for element (Washable) PS400

SAF800E4
388x1322x884 309-359 1.48-1.50 65 71 65 71 68 74 76 0.117x2 800 800 650 140 110 70

SAF1000E4
388x1322x1135 360-399 1.85-1.93

Capacity

68 73 76 0.137x2 1000 1000 810 90 55 35

74

Dimensions
All measurements in mm.

SAF250E4,350E4,500E4

SAF800E4

SAF1000E4

Installation reference
Pipe Hood Outside Intake Duct Ceiling Suspension Bolt Supply Air Duct

SA
(Supply Air)

RA
(Room Air)

OA

(Outside Air) Exhaust Air

EA

Room Intake Duct Heat Insulation Material Exhaust Air Duct

Inside Supply Opening (Supply/Exhaust Air Grill)

Room Intake Opening (Supply/Exhaust Air Grill)

Dimension table
NO.
1 2 3 4 5 6 7 8 9 10 11

Unit:mm

Name
Frame Adaptor Electrical Equipment Box Inspection Cover Fan Motor Heat Exchange Element Filter Damper Damper Motor Ceiling Suspension Fixture

Quantity
1 4 1 1 2 2 2 2 1 1 4

Material
Zinc-plated steel ABS Resin Zinc-plated steel ABS Resin

Remarks

Model
SAF250E4 SAF350E4 SAF500E4

a
142 162 202

b
810 810 890

c
599 804 904

d
315 480 500

e
655 860 960

Model
SAF250E4 SAF350E4 SAF500E4

f
219 219 246

g
164 164 210

h
144 144 194

i
882 882 962

j
95 95 107

Flame Retardant Paper + Plastic Air to air Heat Exchanger Non-woven Cloth Collection Efficiency Gravimetric Method 82%

Zinc-plated Steel

Note(1) An inspection port is needed for cleaning the heat exchanger and filter 1 or 2 times a year.