Your partner for tunnel ventilation Product range jet fans Characteristics of a longitudinal tunnel ventilation Modern production ensures a constantly high quality Our services Research and development 9 Technical description of jet fans 10 - 11 Dimensioning charts 12 Dimensioning aid 13 Suspension of jet fans in the tunnel section 14 - 15 Impeller specification 16 Tender text 17 - 20 References for jet fans installed 21 The tunnel of resund 22 Visit our web site 23 3 4 5 6-7 8

Your Partner for Tunnel Ventilation


TLT-Turbo GmbH has more than 100 years of experience in ventilation technology. Our engineers have been working on the development, construction and production of turbo ventilators for more than 30 years. The qualities and advatages, which distinguish our new jet fans in global competition today and in the future and make them successful are: highest efficiency filed aerodynamics optimal sound protection excellent corrosion protection accessories offered in a great variety Current reference. For the complete ventilating system of the Tunnel resund (lenght: 4 km) between Denmark and Sweden, the new fans of TLTTurbo GmbH were installed.

As leading producer of fans and systems with a long tradition, we develop innovative technical solutions with the highest possible efficiency.

Product Range Jet Fans


For short road tunnels, where the natural ventilation is not sufficient, a pure longitudinal tunnel ventilation is used. With this kind of tunnel ventilation the supply of fresh air is realized by jet fans. The pure longitudinal tunnel ventilation is increasingly being used for longer tunnels, too. Jet fans are axial fans with free inlet and outlet section. They are mounted on the ceiling or on the side directly in the cross-section of the tunnel. Jet fans suck in a small amount of the tunnel air and blow it back into the cross-section of the tunnel with a high kinetic energy. In this process an impulse exchange takes place between the propulsion jet and the air column of the tunnel, and this air column is set in motion in the direction of flow. Important qualities are efficiency, aerodynamics, sound and corrosion protection of such systems.
resund Tunnel

Tunnel gate

Characteristics of a Longitudinal Ventilation


Depending on the traffic conditions, the natural ventilation of road tunnels, can be supported, increased, decreased or stabilized by using jet fans. The jet fans create a defined longitudinal speed of the air column in the tube. This speed must be individually adjusted to the respective circumstances (tunnel crosssection, traffic volume, etc.), in order to adhere to the respective effective pollution limits. The disadvantage of a pure longitudinal ventilation is that the pollutant concentration (Ks) linearly increases along the tunnel tube towards the end of the tunnel, because no exchange takes place between polluted tunnel air and fresh air along the length of the tunnel (TL). Therefore, at the end of the tunnel the concentration is the highest (see fig. 1 longitudinal ventilation).
TL
Fig. 1 longitudinal ventilation

For the system of a semi-transversal ventilation (central ventilation stations) jet fans can be used, in order to control the flow of smoke in the case of fire. Thus, for example, a too high flow relocity resulting from thermal current or undesirable direction of flow can be influenced in such a way, that a possible escape route remains free from smoke to a great extent.

Ks

Kzul

For city tunnels, the extraction of polluted air is mostly realized with large axial flow fans at the exit gate, in order to distribute the highly polluted air via an exhaust air duct into the atmosphere, maintaining the immission at the gate within the permissible limits. (see fig. 2 longitudinal ventilation with exhaust system).

Ks

Kzul TL

For longer tunnels with longitudinal ventilation mostly a longitudinal ventilation in sections (intermediate) is used. There the tunnel length is subdivided into several sections. At the end of each section the polluted tunnel air is extracted through divided ducts by means of axial flow fans and at the same time fresh air is blown into the next section. (see fig. 3 longitudinal ventilation in sections).

Fig. 2 longitudinal ventilation with exhaust system

Ks

Kzul TL

With these measures, fires in the tunnel can be controlled better, too.
Fig. 3 longitudinal ventilation in sections

Modern Production Ensures a

Computer-controlled coil plant for cutting sheet metal

Program-controlled CNC nibbling machine

Precise laser cutting in sheet metal working

1000 t deep drawing press

The wide production range of our jet fans is subject to the highest demands and flexibility during production. Motivated specialists, coupled with one of the most modern production processes, ensure constantly high quality and improvement of our products. Through the quality management system in accordance with DIN EN ISO 9001 a continuous improvement of quality is attained for the benefit of our customers.

Excerpt from the declaration of the TLT management regarding quality control: TLT-Turbo GmbH supplies products, which in view of their quality such as technical design, production and service, correspond to the requirements demanded by the customers and the authorities, and which offer a high degree of safety reliability and efficiency. Each unit is subject to a test run within the frame of the ISO EN 9001 before leaving the factory. The test records are attached to the product. We have all important national and international quality certificates.

Silencer assembly

Jet fan assembly

Constantly High Quality

Assembly of jet fans for tunnel ventilation

Pretreatment plant for powder coating

Welding robot

Powder coating plant with pretreatment

Our contribution to environment protection We have taken the following measures for protecting ressources and environment:

Modern surface treatment Powder coating with purification of sewage water Monitored production facilities

Assembly hall for jet fans

Electrostatic powder coating line

Our Services

In addition to the delivery, assembly and commissioning of tunnel fans we also offer complete support during the planning and design for road and railway tunnels as well as for subway ventilation. As turn-key supplier of complete systems, we develop individually optimized solutions for control and monitoring of tunnel fans, including the measuring instruments required.

TLT-Turbo GmbH has developed its own program for the design of longitudinally ventilated tunnels, on the basis of international guidelines such as PIARC, RVS and RABT. Based on this and knowing the key features, we can carry out a complete aerodynamic calculation of the tunnel.

Suspension of jet fan in a rectangular profile

Axial fan in the tunnel of Bad Godesberg

Research and Development

At our research and development department we are permanently improving our product range and adapt it to the most varied requirements. The most modern investigating and testing methods, co-operation with recognized
suction area [C]

universities and international research institutions as well as exchange of experience with our customers ensure, that the latest technological developments in aerodynamics are permanently being integrated into the development of our jet fans.

north south

TLT-Turbo GmbH test dated 18.02.1998


Fire test jet fans: The suitability of the TURBO LUFTTECHNIK jet fans in case of fire at 250C for an operating time of at least 90 minutes was proved during a large-scale test at the independent testing institute of DMT at Dortmund.

Power consumption of fan [A]

At the fan [C]

Technical Description
Jet fans By the term jet fan a unit is understood, which represents the machine ready for operation after installation into the section reserved for traffic and connection to the electric power supply, and which is used for supplying fresh air by means of exchange of impulses between propulsion jet and remaining quantity of air. Fan housing (1). The fan housing consists of three screwed ducts, made of welded sheet steel. As protection against corrosion the housing is galvanized (min. 50 m) and provided with a powder coating (100 m 20 m). The joining elements between the housing elements and the silencers consist of high quality stainless-steel.

A jet fan mainly consists of the following components: the fan housing made of steel sheet S 235 JR welded, galvanized and powder coated. the impeller, made of sea water resistant aluminium cast alloy with individually adjustable light alloy blades. the vibration reducing suspension device for the fan, made of S 235 JR with the damping elements. safety equipment preventing the fan from falling on the road (stainless-steel chains) and a safety switch (optional). the drive motor with cables lead towards outside and the terminal box. silencers on suction and discharge side made from S 235 JR material with perforated plate made from high quality inox steel material group A4. 5 tail fairing 10 silencer 1 fan housing 2 impeller 3 impeller blades 4 nose fairing 6 supporting frame 7 drive motor 8 motor support 9 nozzle

Denomination TAS x
T: A: S: x: Tunnel Axial Jet fan Size (impeller diameter [dm])

Impeller with blades (2 + 3) The impeller is an aluminium alloy casting with blades individually adjustable during standstill. The impeller is completely closed and is therefore optimally protected against corrosion, particularly against crevice corrosion. For high demands with regard to corrosion, e.g. seawater air, the impeller rotor is also powder coated.

10

of Jet Fans
Nose and tail fairings (4 + 5) In front of the impeller there is an aerodynamically designed, non-rotating nose fairing. For unidirectional fans a rotating fairing is used. Nose and tail fairing are provided with the same corrosion protection as the fan housing. On the downstream side of the motor an aerodynamically designed, corrosion protected tail fairing is arranged. Drive motor (7) Three phase current asynchronous squirrelcage motors are used as drive motors for the jet fans. The motors are suitable for direct start-up. The housings are made of cast iron with cooling ribs. Cooling is made through the air stream of the jet fans. The antifriction bearings of the motor bearings are sealed for life. The motor corresponds to the insulation class H with heating in accordance with B and the protection class IP55.

Suspension (6) The jet fans are suspended with a support frame. The fans are fixed with heavy-duty support anchors.

Motor support (8) The motor is fixed in the fan housing by means of sufficiently dimensioned supporting struts. The supporting struts also serve as downstream guiding sheets.

Nozzle and silencer (9 + 10) The inlet and outlet parts of the jet fan are designed as silencers with integrated, aerodynamically optimized nozzle. The support frame consists of reinforced Ubeams, whose upper webs of channels are adapted to the respective tunnel ceiling. The profiled support frames consist of galvanized S 235 JR steel, for protection against corrosion, and they are powdercoated, too. Vibration dampers are arranged fan between the ventilator housing and suspension device. To prevent the fan from falling down, if the dowels become detached, stainless steel chains, which do not to bear any weight under normal operating conditions, are also mounted at the ends of the fan. If the fan falls into these chains, it is automatically switched off by the safety switch (optional) which is mounted at the housing. The silencers are designed in such a way that the required A-weighted sound power level (execution of the acoustic test in accordance with ISO 13350) is met. The silencers are made from a galvanized steel sheet housing, which is provided with the same powder coating as the fan housing and made of stainless steel perforated plates of material group A4. Stainless design As an option, we also offer our jet fans completely made of special steel.

11

Dimensioning Charts

TAS 5,6 TAS 6,3 TAS 7,1 TAS 9,0 TAS 10,0 TAS 11,2 TAS 12,5

Thrust (N)

Silencer length

Electrical power consumption Pauf (kW)

Reversible jet fans Type ... .... TAS 5,6 TAS 6,3 TAS 7,1 TAS 9,0 TAS 10,0 TAS 11,2 TAS 12,5 560 630 710 900 1000 1120 1250 350 450 800 600 960 1400 1600 13 16 32 19 32 50 52 8.5 10.8 16.3 17.8 25.1 33.9 40.5 34.4 34.7 41.0 28.0 31.9 34.4 33.0 Impeller diameter [mm] Thrust [N] Electrical power consumption [kw] Volume flow [m3/s] Air outlet speed [m/s]

Details of the types TAS 14 and TAS 16 can be obtained upon request. All fans listed are 100% reversible! Unidirectional fans are individually dimensioned upon request.
12

Dimensioning Aid
Many influencing factors must be taken into consideration when choosing the ventilation system for tunnel systems. Most important for dimesioning of the ventilating system is the quantity of fresh air required with different traffic densities. TURBO LUFTTECHNIK can give advice and support for dimensioning ventilating systems. With the software developed by us, based on the standards of the relevant guidelines (PIARC, RVS, RABT), the amount of fresh air can be calculated if the boundary conditions and traffic data are known. In order to transport this fresh air through the tunnel by means of jet fans, a certain amount of total thrust is required. In order to calculate this thrust, the resistances which have to be overcome must be determined. They consist of: Wind pressure

p3 = vW 2
2

The resulting total pressure (pt= pi) must be overcome by the installed jet fans. The required total thrust results from:

Stot = pt AT
The thrust indicated in the data lists is always the static thrust SSt measured on the test stand in the free field. In the tunnel this static thrust is reduced to an effective thrust by the interfering tunnel flow stream and the proximity of the suspension device to the wall, which must be taken into account when designing the ventilation system. The effective thrust Seff appearing in the tunnel results from:

Friction losses in the tunnel Inlet and outlet losses at the gates Piston effect of the vehicles Cross sectional obstructions due to vehicles or other installations Thermal flows in the tunnel Wind load stressing on the gates The resulting pressure losses can be essentially arithmetically determined with the aid of the following three formulas:

vT Seff = k (1- ) SSt = k j SSt vjet


Symbols
l DH v AT N Cw A k Loss coefficient of tunnel gate Coefficient of friction of tunnel wall Tunnel length Hydraulic diameter Air density Velocity of the tunnel air (T), the vehicles (VEH), the wind (W) and the outlet of the fan Cross section of the tunnel Quantity, vehicles Drag coefficient, vehicles Front surface, vehicles Installation factor

Friction losses

l 2 p1 = 1 + + vT SIGN (vT) 2 DH

Pressure losses resulting from vehicles


2 1 p2 = (NPKW CwPKW APKW + NHGV CwHGV AHGV) (vveh-vt ) SIGN (vT -vveh) 2 AT

13

Suspension of Jet Fans


The installation factor k is determined by the small distance of the suspension device to the wall. In diagram 1 k is represented as a function of the distance ratio z/d. In diagram 1 the optimal distance to the ceiling is listed over the construction size, whereas optimal is to be judged as a compromise between distance to the ceiling and distance to the clearance gauge. Other influencing factors, which have to be considered for the technical design of the fans are for example backflows from one tube to the other or thermal lift resulting from level differences.

Diagram 1: Installation factor k

Diagram 2: Relative speed factor j

tunnel ceiling

Optimal distance from the ceiling

Type d [mm] z [mm]


Chart 1

TAS 5,6 560 530

TAS 6,3 630 560

TAS 7,1 710 600

TAS 9,0 900 730

TAS 10,0 1000 790

TAS 11,2 1120 850

TAS 12,5 1250 920

14

in the Tunnel Section


Various suspension frames In order to attain an optimal installation factor, the distance to the ceiling must be observed for all kinds of suspensions of table 1. Type TAS 5,6 A (mm) 570 705 760 895 1005 1110 1260 on the right. B (mm) 460 520 590 680 780 880 970

The suspension device consists of two UTAS 6,3 shaped steel plates, TAS 7,1 which are connected with each other by two TAS 9,0 angle sections. For the TAS 10,0 use in a tunnel vault the U-shaped steel plates TAS 11,2 are extended towards TAS 12,5 the contour of the vault. The distances of the holes to be made, please find in the table
A

C: The distances of safety chains depend on the dimensioning of the silencers dimensions. B

(1) Suspension for rectangular profile. This arrangement is mainly used for city tunnels.

2) Suspension for vault profiles (central arangement). This arrangement is mainly used for alpine tunnels.

(3) Suspension for vault profiles (decentral arangement). This arrangement is also mainly used for alpine tunnels.

15

Impeller specification
Consisting of of impeller hub and blades individually adjustable during standstill. The hub is sealed with a cover after being mounted. The closed construction prevents moisture from penetrating into the impeller and to the fixation of the blades. Thus, the danger of cravice corrosion in the area of blade food, is excluded. The completely assembled impeller is statically and dynamically balanced according to quality G2.5 in accordance with DIN ISO 1940. The finished impeller is provided with an extremely abrasionproof powdered varnish as corrosion protection - the suitability of this conception for the aggressive tunnel atmosphere was proved in a 1000 hours salt spray test at an independent test institute.

The closed impeller prevents cravice corrosion

Impeller before powder coating

Impeller after powder coating

Electrostatic powder coating of impellers

16

Tender Text
Price per unit No. Quantity Description Euro Cent Euro Cent Total

Jet fans type TAS The design of jet fans should be as simple and robust as possible. They have to be designed in such a way, that the special conditions in the aggressive tunnel atmosphere do not affect the reliability during the stipulated service life of 20 years.This applies particularly to the corrosion protection. The fan must be able to work properly for 90 minutes at 250C. A corresponding certificate of an independent testing institute is to be submitted.

Impeller The impeller, consisting of a hub and blades individually adjustable during standstill has to be designed for 100% reverse operation. In order to withstand the aggressive tunnel atmosphere, the impeller consists of a seawater resistant AISIMg alloy. In order to avoid crevice corrosion in the area of the fixation of the blades, the impeller is a completely closed construction i.e. the fixation screws must not come into contact with the tunnel atmosphere. The impeller is to be dynamically balanced according to quality G2.5 (DIN ISO 1940). Impeller: Al-casting alloy G-AlSi9Mg wa. Electric drive motor Three-phase current asynchronous sqirrel-cage rotor in accordance with IEC guidelines without built on fan. The motor has to be mounted in the fan housing by means of a 4-point fixation (IMB 30). A fixation of the flange next to the impeller is not possible. The flange protection class of the motor is IP 55 with insulation class H, according to B and suitable for direct start up. The antifriction bearings are sealed for life with a life of min. 40000 h. The motor windings are made with cold conductors for temperature monitoring. The motor must be suitable for an operating time of 90 minutes at 250C. The cables (power and monitoring) must be free from halogen and flameproof and connected to the external terminal box.

17

Tender Text
Price per unit No. Quantity Description Euro Cent Euro Cent Total

Fan housing with motor support Standard housing with welded fixation struts for the centric installation of the drive motor. All welding seams are continuously welded. On the outside of the housing there is a powder coated terminal box made of aluminium casting for the motor cables. Suitable screwed cable glands made of brass are to be provided for connection. The size as well as the terminal area must be agreed upon in advance with the customer. Housing and silencer: Steel S235JR, galvanised in accordance with ISO 1462 (min. 50 m) and powder coated RAL 7030 (100 m). In front of the impeller guiding ribs with a corresponding tail fairing are arranged for the optimization of aerodynamics.

Silencers Each silencer is to be equipped with an aerodynamically shaped inlet nozzle, which is welded continuously the outer shell of the silencer. The perforated plate is made from A4 inox steel. Between the perforated plate and the outer shell the sound absorbing, non-inflammable fibre wool is to be arranged. To prevent the fibre wool from coming out through the perforated plate, a water-repellent, sound pervious glass fleece is to be inserted. The silencers have to be dimensioned in such a way, that the sound power level indicated in the data list wont be exceeded.

Suspension The jet fans have to be mounted on the ceiling parallel to the longitudinal axis of the tunnel. The mounting frame has to be a rigid welded construction. Heavy duty support anchors made of Inox steel 1.4529 approved for zonessubjekt to tensile forces have to be used. No vibrations may be be transferred to the tunnel ceiling, therefore vibration dampers have to be provided.

18

Tender Text
Price per unit No. Quantity Description Euro Cent Euro Cent Total

Ceiling support frames: Steel S235JR, galvanized in accordance with ISO 1462 (min. 50 m) and powder coated RAL 7030 (100 m). Suspension frames for flat ceilings or or suspension frames for vaulted ceilings, centric suspension frames for vaulted ceilings, inclined

Safety chains In case the suspension fails, the fan is protected from falling onto the road by safety chains. On the silencer ends safety chains made of stainless steel have to be arranged on the tunnel ceiling independent of the suspension frames. Heavy duty anchors from 1.4529 have be arranged as well. Under normal operating conditions the chains do not bear any load.

Safety switch The fan is automatically switched-off by the safety switch, which is attached to the housing. The safety switch is designed as an opening safety switch.

Technical data of the fan Impeller diameter: Reversible static thrust: Shaft capacity: Volume flow: Reference density: Sound power level: Basis: ISO 13350 1.21 [N] [kW] [m3/s] [kg/m3] [dB(A)] [mm]

19

Tender Text
Price per unit No. Quantity Description Euro Cent Euro Cent Total

Technical data of the motor Nominal voltage: Mains frequency: Nominal power: Nominal current: Synchronous speed: Insulation class: Protection class: Operating mode: Bearing life: Type: Motor make: 400 50 [V] [Hz] [kW] [A] [min-1] H with class B temperature rise IP 55 S1 at least 40.000 h IMB 30 West-European manufacturer

Make: Type: Accessories

TLT-Turbo TAS

K Monitoring of the bearing temperature by means of cold conductors (PTC). K Monitoring of the bearing temperature by means of resistance-thermometer (PT100) on the motor bearing. K Control of the bearing temperature by means of resistorthermometer (PT100) on the motor winding. K Monitoring/control of the antifriction bearing condition (SPM). K Monitoring of vibration by means of vibration fensor. K Monitoring of vibration by means of vibration measuringsystem. K Monitoring of breaking off (detachment of the fan fixation. K Standstill heating for drive motor. K Evaluation instruments for the mentioned monitoring equipment

20

References for jet fans installed


Tunnel Country Fan type Quantity Year of construction 1968 1979 1979 1984 1984 1984 1984 1985 1985 1985 1986 1986 1987 1987 1989 1990 1991 1991 1993 1994 1994 1994 1995 1996 1996 1996 1996 1996 1996 1996 1996 1996 1997 1997 1998 1998 1999 1999 1999 1999 2000 2000 2000 2000 2000

Tunnel du chat Dalaaser Tunnel Flirscher Tunnel Tanzenberg Citytunnel Bregenz Bochum Westtangente Ministerium Straen und Transport Wolfsbergtunnel Hugenwaldtunnel Hugenwaldtunnel Niklasdorftunnel Cassanawaldtunnel Sarganz Lan Zhou Qi Roppener Tunnel Karawanken Habsburg Schinznacher Feld Wattwil Pians Quadratsch Bielefeld A22 berdeckung Stephanshorn Tunnel Caluire Tunnel Tuhobic Tunnel Sleme Tunnel Sopac Daboo Tunnel dAignebelle Tunnel dHurtieres Tunnel Vrsek Tunnel Lucice Tunnel Les Vignes Trance couverte de Combette Galerie de Develier Bad Godesberg Tunnel Britz Tunnel Landeck Schnberg Tunnel resund Link Tunnel Birchi Tunnel Gorges du Seyon Tunnel Vue des Alpes Tunnel Juk-Ryoung Baregg-Tunnel

France Austria Austria Austria Austria Germany Iran Austria Germany Germany Austria Switzerland Switzerland China Austria Austria Switzerland Switzerland Switzerland Austria Germany Austria Switzerland France Kroatien Croatia Croatia South Corea France France Croatia Croatia Switzerland Switzerland Switzerland Germany Germany Austria Austria Denmark Switzerland Switzerland Switzerland Corea Switzerland

TAS 8,0 TAS 9,0 TAS 9,0 TAS 14,5 STVN 7-15/2 STVNR 6-11/2 STVN 7-15/2 STVN 12-37/4 STVNR 7-15/2 STVNR 5-3/2 STVNR 14-15/8 STVNR 7-11/2 STVNR 10-30/4 TAS 9,0 STVNR 12/45/6 TAS 18,0 TAS 13,5 TAS 13,5 TAS 9,0 TAS 9,0 TAS 11,2 TAS 5,0 TAS 9,0 TAS 12,5 TAS 12,5 TAS 12,5 TAS 12,5 TAS 10,0 TAS 11,2 TAS 11,2 TAS 12,5 TAS 12,5 TAS 12,5 TAS 12,5 TAS 10,0 TAS 6,3 TAS 6,3 TAS 10,0 TAS 10,0 TAS 7,1 TAS 6,3 TAS 6,3 TAS 6,3 TAS 10,0 TAS 13,5

6 16 6 15 16 16 32 3 16 1 13 18 32 14 4 24 42 4 13 16 11 88 2 56 50 50 50 12 20 24 6 4 24 8 8 30 72 2 12 200 58 14 8 8 4

21

The resund-Tunnel

With 200 jet fans of type TAS 7.1 of the latest generation, we are providing fresh air in the resund Link.

The resund Link is an impressive tunnel and bridge connection between Denmark and Sweden.

The construction of the 4,050 m long tunnel was necessary, because a continuous bridge would have an adverse effect on the air traffic of the airport in the neighbouring city of Copenhagen.

An artificial island is connected to the tunnel from where the route is led on the 7,845 m long bridge.

22

Visit our Web Site

Would you like to learn more about TLT-Turbo GmbH? Visit us on the web. On our web sites you can quickly get a comprehensive survey of the service spectrum offered by TLT-Turbo GmbH. We look forward to your visit: www.tlt.de

Business to Customer

You can also obtain further information by email under: tunnel@tlt.de or give us a ring under: Phone + 49.63 32 .80 8-0.

Products

Download

Informations

TLT-Turbo GmbH
Fans, Service and Systems Gleiwitzstrae 7 66482 Zweibrcken/Germany Phone: Fax: + 49 (0)6332-808-0 + 49 (0)6332-808-267

E-mail: tlt@tlt.de Website: www.tlt.de

TLT-Turbo GmbH
Standard- and Industrialfans Am Weinberg 68 36251 Bad Hersfeld/Germany Phone: Fax: + 49 (0)6621-950-0 + 49 (0)6621-950-100

E-mail: serie@tlt.de / industrie@tlt.de Website: www.tlt.de


2008 by TLT-Turbo GmbH 3th edition 08/08/PDF/Bopp Subject to error and modifications.

Você também pode gostar