Você está na página 1de 10

TECHNICAL DATA

SOLIDO, disposable shuttering for ventilated loose stone foundations


Pressures at the bottom of the structure
Hypothetic load Kg/m2 Slab thickness cm Pressure at pillar base Kg/cm2 Lean concrete thickness cm Scree thickness cm Ground pressure Kg/cm2

Accessories
Frequent sizing
AREA
Loads
Kg/m2

Graphical analysis of the behaviour of the concrete structure

l
Slab thickness
Kg/cm2

Pressure at pillar base


cm

Rod diameter
mm

Rod diameter
cm

The stopcasting panel


h

The extension A component in expanded polystyrene of suitable density to resist concrete pressure, which makes it possible to develop a ventilated oor in any shape or size. The advantages are: registration of extension stretching up to 50 cm in length; casting in a single phase of the substructure grating and the ventilated oor, saving on reinforcement and dismantling operations; perfect development of the ventilated oor even for plans with a complex shape and size; reduction of need for shuttering shaping.

5 450 4 1,68 10

0 15 25 0 15 25 0 15 25 0 15 25 0 15 25 0 15 25 0 15 25 0 15 25

0,49 0,11 0,09 0,25 0,07 0,06 0,63 0,13 0,10 0,31 0,08 0,07 1,03 0,19 0,13 0,50 0,11 0,09 1,67 0,30 0,19 0,79 0,16 0,11
View of the extensional state of the Mxx slab View of the extensional state of the Sxx slab View of the Ideal Tension of the Von Mises Criterion slab View of the dimensions of the model in 3 x 3 m plan submitted to structural analysis View of the extensional state of the Mxy slab View of the extensional state of the Sxy slab

Areas not susceptible to crowds (houses and relative services, ofces not open to the public)

450

1,68

20x20

5 650 4 2,16 10

Areas susceptible to crowds (restaurants, cafs, banks, hospitals, ofces open to the public, barracks).

650

2,16

20x20

The stopcasting panel is a component in recyclable plastic, preshaped and of variable size p adaptable to any height that allows: closing of the self-supporting, platform shutters in order to prevent lling during the casting phase; the creation of perimetral stringcourses simultaneous to oor casting etc.; signicant reduction of reinforcement and dismantling times (up to 80%). Stopcasting panels occupy very little space and are of no hindrance in building yard spaces.

5 1200 5 3,55 10

Garages, car parks, warehouses, archives, libraries

1200

3,55

20x20

5 2100 6 5,78 10

Areas for industrial use

2100

5,78

20x20

The table expresses, starting from the various examples of overload and of thickness (to be given to the slab), the pressures that would be applied to the feet of the structure, in relation to (any) thicknesses of the lean concrete and of the scree. (Table relating to SOLIDO H 25 cm)

The loads shows are those which are usually used, while the effective capacities are higher. (Table relating to SOLIDO H 25 cm)

Technical data and packing

H in cm.
Useful sizes*
50 (57,8)

4
50x50 2,2 2,2 2,2 0,0016 0,800 110x110x230 500 600 150 3 205 16

6
50x50 3,9 3,9 3,9 0,0019 0,840 110x110x230 520 600 150 3 205 15

8
50x50 5,9 5,9 5,9 0,0022 0,875 110x110x240 640 600 150 6 205 13

10
50x50 5,8 5,8 5,5 0,013 1,200 110x110x220 576 480 120 8 205 11

12
50x50 7,7 7,7 7,5 0,021 1,225 110x110x220 576 480 120 10 205 9

14
50x50 9,8 9,8 9,4 0,028 1,250 110x110x230 420 340 85 12 205 7

16
50x50 11,8 11,8 11 0,030 1,275 110x110x220 420 320 80 14 205 11

18
50x50 13,8 13,8 12,5 0,033 1,300 110x110x220 430 320 80 16 205 9

20
50x50 15,5 15,8 13,5 0,034 1,325 110x110x220 430 320 80 18 205 7

22
50x50 17,8 17,8 15 0,036 1,350 110x110x225 440 320 80 20 205 15

25
50x50 20,5 20,5 15 0,039 1,450 110x110x225 450 320 80 23 205 12

27
57,8x57,8 22,5 22,5 16,8 0,043 1,800 120x120x240 560 300 100 25 205 7

30
50x50 26,3 25 13 0,046 1,600 110x110x250 510 320 80 28 205 7

35
50x50 31,3 26,5 14,5 0,052 1,700 110x110x255 540 320 80 33 205 17

40
50x50 36,3 28,5 15 0,058 1,800 110x110x260 570 320 80 38 205 12

45
50x50 41,3 29,5 16 0,064 1,900 110x110x250 570 300 75 43 205 7

50
57,8x57,8 45,5 30,8 16,6 0,077 2,880 120x120x260 725 240 80 48 205 17

60
57,8x57,8 55,4 33,6 18,1 0,083 3,085 120x120x262 725 228 76 59 205 7

cm h cm A 1 x cm B 1 x cm m3/m2 Kg axbxc Weight Kg.


c

Height h Tunnel clear span Max diameter of tube Max diameter of tubes Consumption of razed concrete

50 (57,8) 52 (59,5)

Weight of each single piece Bed Base

Pieces
a b

Mq H cm L cm

Stopcasting panels

A B B

P cm

Il materiale non teme le intemperie e pu pertanto essere stoccato allesterno.

*In considerazione del materiale riciclato ammessa una tolleranza dimensionale del 1,5%. In funzione delle diverse altezze la foggia del cassero differir da quella in pianta.

Você também pode gostar