Escolar Documentos
Profissional Documentos
Cultura Documentos
3 3
2. Amplify and explain in brief the following terms related with Power Generation:
a. CHP b. AHP c. BTG Control Room 3. Differentiate between Control Relay & Standard Relay. 4. Differentiate between MCB & MCCB. 5. Differentiate between MCCB & MPCB. 3 3
6. List 7 different Switch Gears and 5 different Control Gears that are generally
3 used for assembling MCC / PCC. 7. Differentiate between A / B / C Curve MCBs. 3 3 3
8. In what all cases Cathodic Protection is applicable 9. What do you understand by Soil resistivity & Corrosivity ? 10. What do you understand by PERMANENT REFERENCE ELECTRODES in an ICCP System?
3
3 3 3
17. Explain 18. Explain 19. Explain 20. Explain 21. Explain 22. Explain
23. Explain 24. Explain 25. Explain 26. Explain 27. Explain 28. Explain 29. Explain 30. Explain 31. Explain 32. Explain 33. Explain 34. Explain 35. Explain 36. Explain 37. Explain 38. Explain 39. Explain 40. Explain 41. Explain 42. Explain 43. Explain 44. Explain 45. Explain 46. Explain 47. Explain 48. Explain 49. Explain 50. Explain 51. Explain 52. Explain 53. Explain 54. Explain 55. Explain 56. Explain 57. Explain 58. Explain 59. Explain 60. Explain 61. Explain 62. Explain 63. Explain 64. Explain 65. Explain 66. Explain 67. Explain
in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief brief
: : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : :
Arc Chute Assembly Branch Ckt Bus Bar Ckt Breaker Contactor Control Relay DC Drive DIN Rail Explosion Proof Enclosure Full Voltage Starter Fuse Fuse Class Electrical Ground Ground Fault Interrupter Inverter Ladder Logic Limit Switch MCCB MCB Motor Control Centre Motor Starter Over Load Relay Over Load Relay Class Power & Power Factor PID Control Push Button Reactive Power Rectifier Reduced Voltage Starter Variable Speed Drive Variable Frequency Drive VAR True Power TENV TEFC NEMA Starter Ratings Switch Gears Control Gears Plant Batteries VRLA Batteries HVDC PCC Power Transmission Towers MPCB Electrical Sub Station
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 8 8 8 8
68. List and Explain all the major Sub system of DC Power Distribution System in a Plant. 69. List and Explain all the major Sub systems involved in High Tension Power Transmission System. 70. List and Explain all the major Sub systems involved in an ICCP installation for a cross country pipeline. 71. Draw Ckt. schematic to implement an ACOS using Power Contactors.
72. Draw a Block Diagram to explain a DC power Plant. 73. Draw Schematic to explain the operation of a FCBC. 74. Calculate the required Anode Weight for protection of a marine structure
for 20 years with total surface to be protected is 76 Sqm, Current Density is 26mA/M Assume : Safety Factor = 1.3 Anode Consumption rate = 18Kg/Amp-Year Utilization Factor = 0.85 75. List and explain all major equipment that make up a 33KV Sub Station
8 8 5
5 5
10
10 10
80. Explain in detail the sequence of Circuit Operation shown in the Ladder Diagrams below
10
Ladder 1
Ladder 2
Ladder 3