Você está na página 1de 1

380/220V - 3F+N+T

TD-CAF ADOSADO / 66 POLOS

TABLERO DE DISTRIBUCIÓN P.I. = 13.68 kW


CAFETERIA PISO 2 M.D. = 10.67 kW

1x20A 30mA
C1 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ
ALUMBRADO TERRAZA
2x25A

C1a 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ


LUCES DE EMERGENCIA

1x20A 30mA
C2 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ
ALUMBRADO COCINA, AZOTEA
2x25A

C2a 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ


LUCES DE EMERGENCIA

1x20A 30mA
C3 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ
ALUMBRADO COMEDOR
2x25A
1x20A 30mA
C4 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ
ALUMBRADO COMEDOR
2x25A

C4a 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ


LUCES DE EMERGENCIA
R S T

3x2A
1x20A 30mA
C5 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ
VIENE CIRCUITO C2 DEL TAB. TGE 3x40A TOMACORRIENTES COCINA
3-1x10mm2 N2X0H + 1x10mm2 N2X0H(N) + 1x10mm2/T 2x25A
1x20A 30mA
C6 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - BANDEJA / TUB. 20mmØ
TUB. 40mmØ F.G. TOMACORRIENTE REFRIGERADOR COMEDOR
2x25A
1x20A 30mA
C7 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
TOMACORRIENTES VITRINAS CALIENTES
2x25A
1x20A 30mA
C8 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
TOMACORRIENTES VITRINAS CALIENTES
2x25A
1x20A 30mA
C9 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
TOMACORRIENTES COMEDOR
2x25A
1x20A 30mA
C10 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
UNIDAD EVAPORADORA UE2-10 (1440W,220V,1Ø)
2x25A
1x20A 30mA
C11 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
UNIDAD EVAPORADORA UE2-11 (1440W,220V,1Ø)
2x25A
1x20A 30mA
C12 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
UNIDAD EVAPORADORA UE2-12 (1440W,220V,1Ø)
2x25A
1x20A 30mA
C13 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
EXTRACTOR E 2-11 (200W,,220V,1Ø)
2x25A
1x20A 30mA
C14 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
VENTILADOR V 3-1 (3/4 HP, 220V, 1Ø)
2x25A
1x20A 30mA
C15 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
EXTRACTOR E 3-19 (3,0HP,220V,1Ø)
2x25A
1x20A 30mA
C16 1x4mm2 LS0H + 1x4mm2 LS0H(N) + 1x2.5mm2/T - TUB. 20mmØ
VENTILADOR V 3-2 (200W, 220V, 1Ø)
2x25A

380/220V, 3F+N+T
100A, 18kA, 60Hz
ESPACIO DE RESERVA

R,S,T
NEUTRO
TIERRA