Você está na página 1de 6

walk-away system

COMPLETELY AUTOMATIC SYSTEM FOR THE DETERMINATION


OF ESR DIRECTLY

IN EDTA TUBES.

VES
INNOVATIVE

CUBE

rn

CLINICAL

DIAONOSTIC

SYSTEMI

maximum

SAFETY&

operator

protection'

ABSOLUTE AVOIDANCE OF CONTACT WITH BLOOD SAMPLES. THE INSTRUMENT WORKS IN ABSENCE OF WASTE LIQUIDS.

COMPLETELY AUTOMATIC SYSTEM

\
l . .
A

- -.-

"es

be-

FOR THE MINATION OF ESR DIRECTLY IN EDTA TUBES.

I
INSTRUMENT STREAMLINES LABORATORY WORK-FLOW. WALK-AWAY FUNCTION REDUCES TURN-AROUND TIME.

1
rn

PRODUCTIVITY

After loading the samples and reading their identifying bar codes, the two-way connection of the instrument and the complete host integration allow the automatic selection of the samples for which Users can easily communicate with the system through interactive software and a touch screen which allow sample traceability in every operating phase: loading, mixing, analysis, classification and printing of the results.

ESR
testing is required.

ITOUCH [screen

The samples selected for ESR testing are transferred from the "Preparer Module" t o the "Analysis Module" where the
test is executed in four

steps: mixing, first reading. sedimentation

ESR results
for each t e s t are obtained using standard ESR t e s t methods Cthree phases: rouleaux formation, sedimentation and packing]. These results, obtained in 20 minutes.

(20 minutes],
second reading. To ensure traceability, each sample is placed in a specific position of the Sample Holder Rack.

MII\IUT FSI
of SEDIMENTATION

correlate with the westergren citrate reference method la 60 minute test performed a t 1 8"C . l Results from the Ves-Matic Cube 200 follow ICSH recommendations

C Clin Pathol 1 993; 6 1 8 2 3 J 4: 9 - 0 1

TECHNICAL
DIMENSIONS

Dimensions in m m [HxWxD]: 6 5 0 x 6 8 0 ~ 6 9 0 Weight: 80 Kg

ELECTRICAL SPECIFICATIONS
Line voltage: US/CAN: 1 1 0 / 1 2 0 Vac EUR: 2 3 0 Vac
7

OF THE
Continuous loading and random access Test performed directty from cell counter racks Compatible with the most popular brands of EDTA tubes

Frequency: US/CAN: 60 Hz EUR: Power consumption: 5 0 Hz

265 VA

Up to 190 results/hour Results every 19"

ESR Control [4x9 ml) Ref. 1 0 4 3 0 ESR Control [2x9 ml] Ref. 1 0 4 3 4

HARDWARE AND S O W A R E

C O N S U ~
Check Device Trasponder RF: 10.000te* Ref. 1 0 2 9 0 Ref. 1 0 2 9 1 Ref. 1 0 2 9 2 Ref. 10403

Internal and external barcode reader Built-in thermal printer Storage of up to 10.000 data Bdirectional host connection allows for selection of only the samples for which ESR testing is required.

5.000tests
1

.oootests

Thermal Roll Paper [ I pcs]

Two R S 2 3 2 ser~al ports Two USE host connection ports One USB client connection port One Compact Flash slot Internal Qualrty Control Management

R ; U.

NUMBEFIS
Ves-Matic Cube 2 0 0 10370/S 10370/A 10370/BC

DIESSE Diagnostica Senese SpA Via del Pouo, 5 - Loc. S. Martino 5 3 0 3 5 Monteriggioni [SI] Italy Tel. : ++39/0577/3 1.95.60/6 1 / 5 0 Fax: ++39/0577/3 1 .87.63