Você está na página 1de 2

6FM40D-X 12V 40Ah(20hr)

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. Battery Construction
Component Raw material Positive plate Lead dioxide Negative plate Lead Container ABS Cover ABS Safety valve Rubber Terminal Copper Separator Fiberglass Electrolyte Sulfuric acid

General Features

Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. Not restricted for air transport-complies with IATA/ICAO Special Provision A67. UL-recognized component. Can be mounted in any orientation. Computer designed lead, calcium tin alloy grid for high power density. Long service life, float or cyclic applications. Maintenance-free operation. Low self discharge.

Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) 197.5 / 7.78 165.5 / 6.52 170 / 6.69 170 / 6.69 14.7 / 32.4

Performance Characteristics Nominal Voltage 12V Number of cell 6 Design Life 10 years oF(25oC) Nominal Capacity 77 20 hour rate (2.0A, 10.8V) 40Ah 10 hour rate (3.88A, 10.8V) 38.8Ah 5 hour rate (6.97A, 10.5V) 34.85Ah 1 hour rate (25.5A, 9.6V) 25.5Ah Internal Resistance 9.5mOhms Fully Charged battery 77oF(25oC) Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC oF(25oC) 400A(5s) Max. Discharge Current 77 Short Circuit Current Charge Methods: Constant Voltage Charge Cycle use Maximum charging current Temperature compensation Standby use Temperature compensation 900A 77oF(25oC) 14.4-14.7V 12A -30mV/oC 13.6-13.8V -20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)


End Point Volts/Cell 1.60V 1.65V 1.70V 1.75V 1.80V 5min 125 118 113 105 96.2 10min 89.4 85.0 80.5 76.1 69.1 15min 71.2 66.9 64.8 63.0 57.0 30min 41.0 39.7 38.0 37.1 35.4 45min 30.7 30.0 29.9 28.7 28.3 1h 25.5 25.2 24.8 24.5 23.4 3h 10.6 10.3 10.1 9.85 9.62 5h 7.32 7.20 7.07 6.97 6.77 10h 4.14 4.08 4.02 3.95 3.88

20h 2.08 2.06 2.04 2.02 2.00

Discharge Constant Power (Watts at 77oF25oC)


End Point Volts/Cell 1.60V 1.65V 1.70V 1.75V 1.80V 5min 239 222 205 189 177 10min 170 157 149 142 135 15min 137 124 120 117 113 30min 90.6 80.9 78.3 75.8 73.2 45min 68.6 62.5 59.3 58.1 56.9 1h 54.8 50.4 49.6 48.8 47.9 2h 30.8 28.7 27.9 27.4 26.9 3h 22.8 21.5 20.7 20.4 20.0 5h 14.9 14.0 13.8 13.6 13.5

(Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values.

page1 of 2

www.vision-batt.com

6FM40D-X
Charged Volume Voltage Current

12V 40Ah

Discharge characteristic (25 C)

Charge characteristic curve


Constant voltage charge characteristic (0.25CA,25 oC)

12.0
140

(%) (XCA) (V)

Battery voltage(V)

120

0.25 0.20 0.15 0.10 0.05 0

15.0 14.0 13.0 12.0 11.0

CHARGED VOLUME CHARGE VOLTAGE

9.85A 6.97A
9.6

3.88A

100 80 60 40

75A
0

35A 25.5A

5 10 min

20 30

60

3 h

10

20

20 0

CHARGING CURRENT

Discharge time

10

12

14

16

18

20

Charging time (hours)

Relationship between charging voltage and temperature


(V/12V) (V/CELL) (V/8V) (V/6V) (V/4V) 110 100 Capacity(%) 90 80 70 60 50 0 10 20 30 40 50 Ambient temperature( oC) 60 40 0 2

Self-discharge characteristic

15.6 15.0 14.4 13.8 13.2

10.4 10.0 9.6 9.2 8.8

7.8 7.5 7.2 6.9 6.6

5.2 5.0 4.8 4.6 4.4

2.6 2.5 2.4


S TA

CY

CL

EU

SE

2.3 2.2 -10

ND B

Y US

40 oC

30 o C

20 o C

10

12 14 16 18 Storage time: months

20

Life characteristics of standby use


120 100 Capacity(%) 80 60 40 20 0 Capacity(%) 120 100 80 60 40 20 0

Cycle service life in relation to depth of discharge

Testing conditions: floating voltage: 2.27 to 2.30V/Cell o o ambient temperature: 25 C(77 F)

100% D.O.D.

50% D.O.D.

30% Depth of discharge

6 Life(year)

200

400

600

800

1000

1200

1400

1600

Number of cycles(cycles)

Temperature effects on float life


15 120 100 Life(years) Capacity (%) 10 2.30V/Cell 80 60 40 20 0 0 -20

Temperature effects on capacity

C 0 .0 5 0 .1 C 0 .2 C

1.0C 2.0C

10

20

30 Temperature( o C)

40

50

-10

10 20 Temperature( oC)

30

40

50

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2000

MH25860

G4M19906-9202-E-16

Shenzhen Center Power Tech. Co., Ltd.


Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-3)

www.vision-batt.com

Page 2 of 2